advertisement
Nokeval
www.nokeval.com
Yrittäjäkatu 12
37100 Nokia, Finland
Tel.
+358 3-342 4800
Fax.
+358 3-342 2066
8-point indicator 532R for temperature and process signals
• Thermocouples J, K, S, R and J/DIN
• Pt100
• Process inputs 0/4..20 mA, 0..10V
• Display -100..+1999 or-99.9..199.9
• Accuracy 0.1% FS
• Temperature linearized ranges
• Case 96 x 96 x 105mm
•
Power supply230 VAC or 24 VDC
The multipoint indicator 532R is designed to measure and display temporary temperature or process values . Meter is provided with big, robust channel-selector switch which is easy and pleasant to use. In case of process signals the display is scalable on the whole display range. By current input the signal does not breake although the display shows another channel. All the channels must be for the same type of sensor or process signal and for same scaling. If you you need mixed input signals we can offer our processor based multimeter type 538-8 (separate brochure available). The line resistance of measurement distance by Pt100 sensor is compensated by 3-wire measurement up tp 50 ohm. In thermocouple measurement the wires from sensors must be of same material extension wires up to the terminal block of the meter. The internal cold junction compensation assurers the correct temperature measurement in all conditions.
The short lenght and the removable connectors enables easy mounting and dismounting in different types of enclosures.
Model 532R
Digital display
120,1
°C
Multipoint display is easy to use and no programming is needed
8-input channels
Thermocouple sensor
K, J, T, R and S
Pt100 sensor process inputs 0/4..20 mA
Channel selection with big, robust selector switch
By current inputs the signal does not breake although different channels are displayed
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
CH 8
Interchangeable input cards
Selector switches
3 poles, 8 channels
Power supply 230 VAC or 24 VDC
SPECIFICATIONS
Pt100 sensor
Sensor:
Accuracy:
Sensor connection:
External lead wire effect:
Sensor current:
Pt100 according to DIN 43760
<0.1% of span + 1 digit
3-wire connection
0.004%/
Ω/wire, max. 50 Ω
0.7 mA
Response time:
Resolution:
Temperature coefficient:
<200 ms
1°C or 0.1°C
<0.005% of span/°C
Thermocouple sensor
Thermocouple types: J, K, T, L
Accuracy:
Input impedance:
<0.15% of span + 1 digit
>10 M
Ω
Cold junction compensation: <0.1°C/°C
External lead resistance: no effect up to 10 k
Ω
Burnout indication: upscale
Resolution: 1°C
0/4...20 mA input
Display (same to all inputs) selectable according to customer range (-100...1999).
Decimal selectable.
General
Display:
Power:
Operation temperature:
Storage temperature:
3½ digit, bright, red LED, 14,2 mm
24, 110, 240 VAC
0...+50°C
-30...+70°C
Humidity:
Terminal connectors:
Cutout:
Case dimensions:
Temperature ranges
J
L
T
Sensor type
Pt100
Pt100
K
Range code
200
700
1200
650
650
300 to 90% RH, non-condensing
1.5 mm 2
91 x 91 mm
96 x 96 x 105 mm
Range °C
- 100...+ 199.9
- 100...+ 600
- 40...+1200
- 40...+ 650
- 50...+ 650
- 50...+ 300
How to order
Model
Sensor type
Range code
Power supply
Example order:
532R – Pt100 – 200- 230 VAC
Sensor Pt100, range –100...+199.9°C
CONNECTIONS
Pt100 - inputs
CH 8 CH 7 CH 6 CH 5
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
CH 1 CH 2 CH 3
Thermocouples
CH 8 CH 7 CH 6
CH 4
CH 5
+ + + + -
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
+ + + + -
CH 1 CH 2 CH 3 CH 4 mA - inputs
CH 8 CH 7 CH 6 CH 5
+ + + + -
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
+ + + + -
CH 1 CH 2 CH 3 CH 4
Dimensions
96
CH 7
25 26 27 28 29 30
CH 6
N L
Power supply
230V AC
CH 5 CH 8
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
CH 1 CH 2 CH 3 CH 4
Optional power supply 24 VDC, terminals 28 (-) and 30 (+).
100.0
110
max. 10
Panel cutout: 91,5 x 91,5 mm ±0.5 Dmensions: mm
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project