81-0001RK-33

81-0001RK-33
MATERIAL SAFETY DATA SHEETS
A-172/E-1
DATE: 29Apr2011
SUPPLIER ADDRESS:
Air Liquide
6141 EASTON RD
PO BOX 310
PLUMSTEADVILLE, PA 18949-0310
EMERGENCY PHONE NUMBER:
(215) 766-8860
------------------------------------------------------------------------------------1. CHEMICAL PRODUCT
------------------------------------------------------------------------------------PRODUCT NAME: FID FUEL H2/HE
SYNONYMS: Hydrogen in
Helium, Flame
Ionization Fuel Mixture
------------------------------------------------------------------------------------2. COMPOSITION, INFORMATION ON
INGREDIENTS
------------------------------------------------------------------------------------Exposure
Limits (PPM)
ACGIH
OSHA
Other
Ingredient Name
Formula
CAS#
Concentration
TLV
PEL
MAC
STEL
HYDROGEN
H2
1333-74-0 40%
S/A
S/A
S/A
S/A
HELIUM
He
7440-59-7 60%
S/A
S/A
S/A
S/A
Note: S/A = SIMPLE ASPHYXIANT
------------------------------------------------------------------------------------3. HAZARD IDENTIFICATION
------------------------------------------------------------------------------------***
EMERGENCY OVERVIEW
***
Flammable, high pressure gas.
Can form explosive mixtuers with air.
Burns with an invisible flame.
POTENTIAL HEALTH EFFECTS
ROUTES OF ENTRY: Inhalation
ACUTE EFFECTS: Mixture can act as a simple asphyxiant by displacing
air
necessary for life. Symptoms include rapid respiration, muscular
incoordination,
fatigue, dizziness, nausea, vomiting, unconsciousness, and death.
CHRONIC EFFECTS: None known
MEDICAL CONDITIONS AGGRAVATED BY OVEREXPOSURE: None known
OTHER EFFECTS OF OVEREXPOSURE: None
CARCINOGENICITY (US Only):
NTP - No
IARC MONOGRAPHS - No
OSHA REGULATED - No
------------------------------------------------------------------------------------4. FIRST AID MEASURES
------------------------------------------------------------------------------------INHALATION: Immediately remove victim to fresh air. If breathing has
stopped,
give artificial respiration. If breathing is difficult, give oxygen.
EYE CONTACT: None
SKIN CONTACT: Non
INGESTION: None
IN EVENT OF EXPOSURE, CONSULT A PHYSICIA
NOTE TO PHYSICIAN: None
------------------------------------------------------------------------------------5. FIRE FIGHTING MEASURES
------------------------------------------------------------------------------------FLASH POINT: N/Ap
AUTOIGNITION TEMPERATURE: N/Av
FLAMMABLE LIMITS: Vol. % for Hydrogen
LOWER: 4
UPPER: 75
EXTINGUISHING MEDIA: Dry chemical,
carbon dioxide, or halogenated gas.
SPECIAL FIRE FIGHTING INSTRUCTION AND
EQUIPMENT: Wear self-contained breathing
apparatus and full protective clothing.
Fires in cylinders and storage tanks
should be allowed to burn until nearly
empty. Keep fire exposed cylinders cool
with water spray.
HAZARDOUS COMBUSTION PRODUCTS: None
UNUSUAL FIRE AND EXPLOSION HAZARDS:
Severe when exposed to heat or flame.
Burns with an invisible flame.
------------------------------------------------------------------------------------6. ACCIDENTAL RELEASE MEASURES
------------------------------------------------------------------------------------CLEAN UP PROCEDURES: Evacuate and ventilate area. Check for
invisible flame with
tissue paper. Remove leaking cylinder to exhaust hood or safe
outdoor area.
Remove sources of ignition and combustibles. Shut off source if
possible and
remove source of heat.
SPECIALIZED EQUIPMENT: None
-------------------------------------------------------------------------------------
7. HANDLING AND STORAGE
------------------------------------------------------------------------------------PRECAUTIONS TO BE TAKEN IN HANDLING: Secure cylinder when using to
protect from
falling. Use suitable hand truck to move cylinders.
PRECAUTIONS TO BE TAKEN IN STORAGE:
Store in well ventilated areas. Keep
valve protection cap on cylinders when
not in use. Keep away from oxidizing
agents.
------------------------------------------------------------------------------------8. EXPOSURE CONTROLS/ PERSONAL
PROTECTION
------------------------------------------------------------------------------------ENGINEERING CONTROLS: Provide adequate general and local exhaust
ventilation to
maintain concentrations below flammable limits and to avoid
asphyxiation.
PERSONAL PROTECTION
EYE/FACE PROTECTION: Safety glasses
SKIN PROTECTION: None
RESPIRATORY PROTECTION: In case of
leakage, use self-contained breathing
apparatus.
OTHER PROTECTIVE EQUIPMENT: Safety shoes
when handling cylinders.
------------------------------------------------------------------------------------9. PHYSICAL AND CHEMICAL PROPERTIES
------------------------------------------------------------------------------------APPEARANCE: Colorless
ODOR: Odorless
PHYSICAL STATE: Gas
VAPOR PRESSURE: N/Ap
VAPOR DENSITY (AIR=1): 0.104-0.134
BOILING POINT (C): N/Ap
SOLUBILITY IN WATER: 0.0068
SPECIFIC GRAVITY (H2O=1): Gas
EVAPORATION RATE: Gas
ODOR THRESHOLD: N/Ap
------------------------------------------------------------------------------------10. STABILITY AND REACTIVITY
------------------------------------------------------------------------------------STABILITY: Stable under normal storage conditions.
CONDITIONS TO AVOID: Storage in poorly
ventilated areas.
MATERIALS TO AVOID: Oxidizing agents.
HAZARDOUS POLYMERIZATION: Will not
occur.
HAZARDOUS DECOMPOSITION: None
------------------------------------------------------------------------------------11. TOXICOLOGICAL INFORMATION
------------------------------------------------------------------------------------LETHAL CONCENTRATION (LC50): NONE ESTABLISHED
LETHAL DOSE 50 (LD50): N/Ap
TERATOGENICITY: N/Ap
REPRODUCTIVE EFFECTS: N/Ap
MUTAGENICITY: N/Ap
------------------------------------------------------------------------------------12. ECOLOGICAL INFORMATION
------------------------------------------------------------------------------------No adverse ecological effects are expected.
------------------------------------------------------------------------------------13. DISPOSAL CONSIDERATIONS
------------------------------------------------------------------------------------WASTE DISPOSAL METHOD: Dispose of non-refillable cylinders in
accordance with
federal, state and local regulations. Allow gas to vent slowly to
atmosphere in
an unconfined area or exhaust hood. If the cylinders are the
refillable type,
return cylinders to supplier with any valve outlet plugs or caps
secured and
valve protection caps in place.
------------------------------------------------------------------------------------14. TRANSPORT INFORMATION
------------------------------------------------------------------------------------CONCENTRATION: 40-60%
DOT DESCRIPTION (US ONLY):
PROPER SHIPPING NAME: Compressed gases,
flammable, n.o.s.
HAZARD CLASS: 2.1 (flammable)
IDENTIFICATION NUMBER: UN1954
REPORTABLE QUANTITIES: None
LABELING: FLAMMABLE GAS
ADR/RID (EU Only): Class 2,1F
SPECIAL PRECAUTIONS: Cylinders should be
transported in a secure upright position
in a well ventilated truck.
------------------------------------------------------------------------------------15. REGULATORY INFORMATION
-------------------------------------------------------------------------------------
OSHA: Process Safety Management: Materials are not listed in
appendix A of 29
CFR 1910.119 as highly hazardous chemicals.
TSCA: Mixture is not listed in TSCA
inventory.
SARA: The threshold planning quantity
for this mixture is 10,000 lbs.
EU NUMBER: N/Ap
NUMBER IN ANNEX 1 OF DIR 67/548: Mixture
is not listed in annex 1.
EU CLASSIFICATION: N/Av
R: 12,20,36/37/38
S: 9,15
------------------------------------------------------------------------------------16. OTHER INFORMATION
------------------------------------------------------------------------------------OTHER PRECAUTIONS: Protect containers from physical damage. Do not
deface
cylinders or labels. Cylinders should be refilled by qualified
producers of
compressed gas. Shipment of a compressed gas cylinder which has not
been filled
by the owner or with his written consent is a violation of federal
law (49 CFR).
ABBREVIATIONS:
N/Ap - Not Applicable
N/Av - Not Available
SA - Simple Asphyxiant
NE - None Established
DISCLAIMER: Information included in this
document is given to the best of our
knowledge, however, no warranty is made
that the information is accurate or
complete. We do not accept any
responsibility for damages by the use of
the document.
Was this manual useful for you? yes no