luxCONTROL lighting control system comfortDIM DALI 3-RM-C DALI control module for 3 relays Product description •Control of up to three standard 24 V DC contactors •1 DALI address per output •5-year guarantee È Standrads, page 3 Wiring diagrams and installation examples, page 3 Data sheet 10/15-CO035-4 Subject to change without notice. www.tridonic.com 1 luxCONTROL lighting control system comfortDIM DALI 3-RM-C DALI control module for 3 relays 42 198 – 254 V Input voltage DC 200 – 240 V Mains frequency 0 / 50 / 60 Hz Power < 30 W Ambient temperature ta -25 ... +45 °C Type of protection IP20 167 143–148 42 Input voltage AC 31 Technical data Ordering data Type Article number Packaging, carton Weight per pc. DALI 3-RM-C 28000868 20 pc(s). 0.155 kg Specific technical data Type DALI 3-RM-C Inputs Current draw Number of DALI addresses Output voltage DC Output power 1 2 mA from DALI 3 3 x 24 V 25 W Data sheet 10/15-CO035-4 Subject to change without notice. Outputs DALI control input www.tridonic.com 2 luxCONTROL lighting control system comfortDIM Standards EN 61558-2-17 EN 61547 EN 55015 EN 61000-3-2 IEC 60929 (according to DALI standard V0) Glow-wire test according to EN 61347-1 passed. Function •DALI controller for controlling up to three standard 24 V DC contactors •Can also be used for status display purposes; via 24 V signal lamps •Each output can be controlled separately Properties •Three independent short DALI addresses with a DALI power consumption of 2 mA •Short-circuit shutdown feature with automatic restart •DC supply possible •Constant output voltage •Strain relief and terminal cover •Captive screw terminal •Maximum cable cross-section 2.5 mm² •Protection class 2 Assembly/installation •The DALI 3-RM-C is connected to the DALI bus and to the mains supply. •The contactor coils must be equipped with an appropriate threshold diode. •24 V signal lamps can be connected directly. •DALI is not SELV. The installation instructions for low voltage therefore apply. Wiring L N F1 DALI PS PCA EXCEL one4all DALI 3-RM-C LOAD DALI GC DALI SC DALI SCI Data sheet 10/15-CO035-4 Subject to change without notice. www.tridonic.com 3 luxCONTROL lighting control system comfortDIM Circuit diagram for three contactors with a maximum power of 8 W DALI 3-RM-C -Ch1 K2 A2 A1 K3 A2 K1 24V DC max. 8W A2 24V DC max. 8W A1 24V DC max. 8W A1 -Ch2 -Ch3 The contactors must be equipped with an appropriate threshold diode. Operation without a threshold diode is not permitted. The controller is designed for a maximum load of 25 W. This load can be split among the three channels. The loads may be distributed asymmetrically. Circuit diagram for one contactor with a maximum power of 25 W DALI 3-RM-C -Ch1 -Ch2 -Ch3 A1 24V DC max. 25W A2 K1 Outputs Ch1 and Ch3 may not be short-circuited. The entire output may flow via one output. Data sheet 10/15-CO035-4 Subject to change without notice. www.tridonic.com 4 luxCONTROL lighting control system comfortDIM Example of a main circuit F1 21 22 5/L3 13 6/T3 14 1/L1 3/L2 2/T1 A1 4/T2 L A1 K1 OGLS 400 N Please check the inrush currents of the switched loads. Electronic control gear may have very high inrush currents. Check with the contactor manufacturer. Circuit diagram for three 24 V signal lamps DALI 3-RM-C -Ch1 -Ch2 -Ch3 24V DC max. 8W 24V DC max. 8W 24V DC max. 8W H1 H2 H3 Signal lamps can be connected directly. The controller is designed for a maximum load of 25 W. This load can be split among the three channels. The loads may be distributed asymmetrically. Data sheet 10/15-CO035-4 Subject to change without notice. www.tridonic.com 5
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement