OPERATING INSTRUCTIONS AM-86X65 ANALOGUE PANEL METER INTENDED USE

OPERATING INSTRUCTIONS AM-86X65 ANALOGUE PANEL METER INTENDED USE
EXPLANATIONS OF SYMBOLS
At the scale’s face different symbols are attached, that have the following significance:
Accuracy class related to the scale
2.0 end value
Installation position vertical
Direct voltage/-current (DC)
ITEM NO.: 10 30 69
ITEM NO.: 10 30 70
ITEM NO.: 10 30 71
VERSION 03/13
100 µA/DC
100 mA/DC
1 mA/DC
INTENDED USE
INSTALLATION
Assembly and installation may only be carried out by a specialist, who is
familiar with the relevant regulations and the ensuing risks.
Mount the measuring instrument with the assembly material included in a pre-assembled
rectangular front panel opening. Carefully attach the fixed measuring instrument. You can get
the corresponding dimensions (in mm) from the following sketch.
9.3 11.0
11.0
85.5
ø 3.0
For safety and approval purposes, you must not rebuild and/or modify this product. If you use
the product for purposes other than those described above, the product may be damaged.
In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc.
Read the instructions carefully and keep them. Make this product available to third parties
only together with its operating instructions.
ø 3.0
• Meter
.0
DELIVERY CONTENT
5
ø4
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
44.5
ø 3.0
43.5
The analogue panel meters are designed for installation in switch cabinets or display panels
and are only suitable for DC measurements. The installation occurs directly without external
components; appropriate pre-resistors are already integrated in the circuit. Only in integrated
status they may be put into operation. The suitable regulations are to be observed. The fixed
measuring instruments are available with different measurement ranges. The scale needle can
be adjusted precisely with the front screw.
64.5
AM-86X65 ANALOGUE PANEL METER
Moving coil instrument
18.0
OPERATING INSTRUCTIONS
ø 3.0
CONNECTION
In order to ensure a correct start of operation, you should read these
operating instructions including the safety instructions thoroughly and
attentively before using the device.
• Operating instructions
Do not connect when the wires are live.
Connection of the panel meter has to be done in series connection. Connect the panel meter
to the screw-type terminals on the back.
SAFETY INSTRUCTIONS
DISPOSAL
• Mounting material
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the
warranty/guarantee.
a) Persons / Product
• The device must not be used in damp interiors or outdoors in the open air.
• The fixed measuring instrument must not be used for medical purposes.
• Be especially cautious in dealing with voltage >35 V/DC. Already at this voltage
you can get a life-threatening electric shock when touching electric lines.
• De-energise the electric system before installing the measuring instrument.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protect it from any accidental use. Safe operation can no longer be guaranteed if
the product:
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the relevant
statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
TECHNICAL DATA
Item no.:
Measurement range
(full-scale deflection):
10 30 69
100 µA/DC
10 30 70
100 mA/DC
10 30 71
1 mA/DC
Movement......................................Moving coil
Accuracy class...............................2.0
Installation-Ø.................................45 mm
Operating conditions......................-25 to +55 °C, 20 – 95 % RH (non-condensing)
Storage conditions.........................-40 to +70 °C, 20 – 95 % RH (non-condensing)
Weight...........................................approx. 65 g
-- is visibly damaged,
-- is no longer working properly,
-- has been stored for extended periods in poor ambient conditions or
-- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
can damage the product.
• Also observe the safety and operating instructions of any other devices which are
connected to the product.
b)Miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the
device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
If you are not sure about the correct connection or use, or if questions arise which are not
covered by these operating instructions, please do not hesitate to contact our technical
support or another qualified specialist.
Voltcraft®, Lindenweg 15, D-92242 Hirschau, Tel. +49 180/586 582 7.
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2013 by Voltcraft®
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement