HP 8753ET, 8753ES Network Analyzer Installation and Quick Start Guide
Below you will find brief information for Network Analyzer 8753ET, Network Analyzer 8753ES. The HP 8753 Network Analyzer is a powerful and versatile instrument that can be used to make a wide range of measurements on network devices. It is able to measure transmission, reflection, and other characteristics of networks and devices. The analyzer can be used to test the performance of network cables, connectors, and other network components.
PDF
Download
Document
Advertisement
Advertisement
Installation and Quick Start Guide HP 8753ET/ES Network Analyzer HP Part Number: 08753-90471 Printed in USA Print Date: August 1999 Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. © Copyright 1999 Hewlett-Packard Company ii Certification Hewlett-Packard Company certifies that this product met its published specifications at the time of shipment from the factory. Hewlett-Packard further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology, to the extent allowed by the Institute's calibration facility, and to the calibration facilities of other International Standards Organization members. Regulatory and Warranty Information The regulatory and warranty information is in the User's Guide. Assistance Product maintenance agreements and other customer assistance agreements are available for Hewlett-Packard products. For any assistance, contact your nearest Hewlett-Packard sales or service office. See Table 2-1 on page 2-27 for the nearest office. Safety Notes The following safety notes are used throughout this manual. Familiarize yourself with each of the notes and its meaning before operating this instrument. WARNING Warning denotes a hazard. It calls attention to a procedure which, if not correctly performed or adhered to, could result in injury or loss of life. Do not proceed beyond a warning note until the indicated conditions are fully understood and met. CAUTION Caution denotes a hazard. It calls attention to a procedure that, if not correctly performed or adhered to, would result in damage to or destruction of the instrument. Do not proceed beyond a caution sign until the indicated conditions are fully understood and met. iii General Safety Considerations WARNING For continued protection against fire hazard replace line fuse only with same type and rating (3A/250V). The use of other fuses or material is prohibited. WARNING This is a Safety Class I product (provided with a protective earthing ground incorporated in the power cord). The mains plug shall only be inserted in a socket outlet provided with a protective earth contact. Any interruption of the protective conductor, inside or outside the instrument, is likely to make the instrument dangerous. Intentional interruption is prohibited. CAUTION Ventilation Requirements: When installing the instrument in a cabinet, the convection into and out of the instrument must not be restricted. The ambient temperature (outside the cabinet) must be less than the maximum operating temperature of the instrument by 4 °C for every 100 watts dissipated in the cabinet. If the total power dissipated in the cabinet is greater than 800 watts, then forced convection must be used. How to Use This Guide This guide uses the following conventions: Front-Panel Key This represents a key physically located on the instrument. SOFTKEY This represents a “softkey,” a key whose label is determined by the instrument’s firmware. Screen Text This represents text displayed on the instrument’s screen. iv Documentation Map The Installation and Quick Start Guide provides procedures for installing, configuring, and verifying the operation of the analyzer. It also will help you familiarize yourself with the basic operation of the analyzer. The User’s Guide shows how to make measurements, explains commonly-used features, and tells you how to get the most performance from your analyzer. The Reference Guide provides reference information, such as specifications, menu maps, and key definitions. The Programmer’s Guide provides general HP-IB programming information, a command reference, and example programs. The Programmer’s Guide contains a CD-ROM with example programs. The CD-ROM provides the Installation and Quick Start Guide, the User’s Guide, the Reference Guide, and the Programmer’s Guide in PDF format for viewing or printing from a PC. The Service Guide provides information on calibrating, troubleshooting, and servicing your analyzer. The Service Guide is not part of a standard shipment and is available only as Option 0BW, or by ordering HP part number 08753-90484. A CD-ROM with the Service Guide in PDF format is included for viewing or printing from a PC. v vi Contents 1. Installing Your Analyzer Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 STEP 1. Verify the Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 STEP 2. Familiarize Yourself with the Analyzer Front and Rear Panels . . . . . . . . . . . . . . .1-5 Analyzer Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Analyzer Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 STEP 3. Meet Electrical and Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . .1-7 STEP 4. Configure the Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9 To Configure the Standard Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-10 To Configure an Analyzer with a High Stability Frequency Reference (Option 1D5) . . .1-10 To Configure the Analyzer with Printers or Plotters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-11 To Configure the Analyzer for Bench Top or Rack Mount Use . . . . . . . . . . . . . . . . . . . . .1-16 STEP 5. Verify the Analyzer Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-20 To View the Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-21 To Initiate the Analyzer Self-Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-22 To Run the Operator's Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-23 To Test the Transmission Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-24 To Test the Reflection Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-25 STEP 6. Back Up the EEPROM Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-26 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-26 Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-26 EEPROM Backup Disk Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-26 2. Quick Start: Learning How to Make Measurements Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 Analyzer Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Measurement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Step 1. Choose measurement parameters with your test device connected . . . . . . . . . . . .2-5 Step 2. Make a measurement calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Step 3. Measure the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Step 4. Output measurement results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Learning to Make Transmission Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 Step 1. Choose the measurement parameters with your test device connected . . . . . . . . .2-6 Step 2. Perform a measurement calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7 Step 3. Measure the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8 Step 4. Output measurement results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9 Measuring Other Transmission Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Learning to Make Reflection Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-14 Step 1. Choose measurement parameters with your test device connected . . . . . . . . . . .2-15 Step 2. Make a measurement calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-16 Step 3. Measure the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-17 Step 4. Output measurement results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-18 Measuring Other Reflection Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-19 If You Encounter a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-24 Power-up Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-24 Data Entry Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-25 No RF Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-25 vii Contents viii 1 Installing Your Analyzer 1-1 Installing Your Analyzer Introduction Introduction This chapter shows you how to install your analyzer and confirm the correct operation, by following the steps below: 1. Verify the shipment. 2. Familiarize yourself with the analyzer front and rear panels. 3. Meet electrical and environmental requirements. 4. Configure the analyzer. 5. Verify the analyzer operation. 6. Back up the EEPROM disk. 1-2 Chapter 1 Installing Your Analyzer STEP 1. Verify the Shipment STEP 1. Verify the Shipment 1. Unpack the contents of all the shipping containers. WARNING: The analyzer weighs approximately 46 pounds (21 kilograms). Use correct lifting techniques. 2. Carefully inspect the analyzer to ensure that it was not damaged during shipment. NOTE If your analyzer was damaged during shipment, contact your nearest Hewlett-Packard office or sales representative. A list of HP sales and service offices is provided in Table 2-1 on page 2-27. ES models only: the PORT 1 and PORT 2 connectors move. This is NOT a defect. Chapter 1 1-3 Installing Your Analyzer STEP 1. Verify the Shipment 3. Verify that all the accessories have been included with the analyzer. 1-4 Part Number Item Number Description 08753-90471 1 Installation and Quick Start Guide 08753-90472 2 User's Guide 08753-90473 3 Reference Guide 08753-90475 4 Programmer’s Guide 08753-90469 5 CD-ROM 08753-10013 6 EEPROM Backup Disk unique to country 7 AC power cable 5062-9216 8 Rack Flange Kit (Option 1CM only) 5062-9236 8 Rack Flange Kit with Handles (Option 1CP only) 5062-9229 8 Front Handle Kit (standard) Chapter 1 Installing Your Analyzer STEP 2. Familiarize Yourself with the Analyzer Front and Rear Panels STEP 2. Familiarize Yourself with the Analyzer Front and Rear Panels Analyzer Front Panel CAUTION Do not mistake the line switch for the disk eject button. See the figure below. If the line switch is mistakenly pushed, the instrument will be turned off, losing all settings and data that have not been saved. 1 LINE (power on/off) switch 8 RESPONSE function block 2 Display 9 ACTIVE CHANNEL keys 3 Disk drive 10 ENTRY block 4 Disk eject button 11 INSTRUMENT STATE function block 5 Softkeys 12 Preset key 6 Return key 13 PROBE POWER connectors 7 STIMULUS function block 14 R CHANNEL connectors 15 ES models only: PORT 1 and PORT 2 Chapter 1 ET models only: REFLECTION and TRANSMISSION 1-5 Installing Your Analyzer STEP 2. Familiarize Yourself with the Analyzer Front and Rear Panels Analyzer Rear Panel 1 HP-IB connector 11 AUXILIARY INPUT connector 2 PARALLEL interface 12 EXTERNAL AM connector 3 RS-232 interface 13 EXTERNAL TRIGGER connector 4 KEYBOARD input (mini-DIN) 14 TEST SEQUENCE 5 Power cord receptacle, with fuse 15 LIMIT TEST 6 Line voltage selector switch 16 MEASURE RESTART 7 Fan 17 TEST SET I/O INTERCONNECT 8 10 MHZ PRECISION REFERENCE OUTPUT* 18 BIAS INPUTS AND FUSES 9 10 MHZ REFERENCE ADJUST* 19 Serial number plate 10 EXTERNAL REFERENCE INPUT connector 20 EXTERNAL MONITOR: VGA *Option 1-6 1D5 only. Chapter 1 Installing Your Analyzer STEP 3. Meet Electrical and Environmental Requirements STEP 3. Meet Electrical and Environmental Requirements 1. Set the line-voltage selector to the position that corresponds to the AC power source. 2. Ensure the available AC power source meets the following requirements: • 90–132 VAC • 47–66 Hz / 400 Hz (single phase) OR • 198–265 VAC • 47–66 Hz (single phase) The analyzer power consumption is 350 VA maximum. 3. Ensure the operating environment meets the following requirements: 4. Verify that the power cable is not damaged, and that the power-source outlet provides a protective earth contact. • 0 to 55 °C • < 95% relative humidity at 40 °C (non-condensing) • < 15,000 feet (≈ 4,500 meters) altitude Some analyzer performance parameters are specified for 25 °C ±5 °C. Refer to the Reference Guide for information on the environmental compatibility of warranted performance. WARNING: Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal, can result in personal injury, or may damage the analyzer. Chapter 1 1-7 Installing Your Analyzer STEP 3. Meet Electrical and Environmental Requirements 5. Ensure there are at least six inches of clearance between the sides and back of either the stand-alone analyzer or the system cabinet. CAUTION: The environmental temperature must be 4 °C less than the maximum operating temperature of the analyzer for every 100 watts dissipated in the cabinet. If the total power dissipated in the cabinet is >800 watts, then you must provide forced convection. 6. Set up a static-safe workstation. Electrostatic discharge (ESD) can damage or destroy electronic components. • static-control table mat and earth ground wire: HP part number 9300-0797 • wrist-strap cord: HP part number 9300-0980 • wrist-strap: HP part number 9300-1367 • heel-straps: HP part number 9300-1308 • floor mat: not available through Hewlett-Packard 1-8 Chapter 1 Installing Your Analyzer STEP 4. Configure the Analyzer STEP 4. Configure the Analyzer This step shows you how to set up your particular analyzer configuration. • standard configuration • Option 1D5 configuration − high stability frequency reference • printer or plotter configuration • rack-mount configuration Chapter 1 1-9 Installing Your Analyzer STEP 4. Configure the Analyzer To Configure the Standard Analyzer Connect test port cables and optional adapters if you are using other connector types. To Configure an Analyzer with a High Stability Frequency Reference (Option 1D5) Connect the jumper cable on the analyzer rear panel as shown. 1-10 Chapter 1 Installing Your Analyzer STEP 4. Configure the Analyzer To Configure the Analyzer with Printers or Plotters 1. Connect your printer or plotter to the corresponding interface. 2. If you are using the parallel interface, press Local and toggle PARALLEL until your choice of COPY or GPIO appears. If you choose COPY , the parallel port is dedicated for normal copy device use (printers or plotters). If you choose GPIO , the parallel port is dedicated for general purpose I/O. The analyzer controls the data input or output through the sequencing capability of the analyzer. Chapter 1 1-11 Installing Your Analyzer STEP 4. Configure the Analyzer 3. Press SET ADDRESSES and then choose either PRINTER PORT or PLOTTER PORT , depending on your hardcopy device. Or, if you are plotting your files to disk, press SET ADDRESSES PLOTTER PORT DISK . 4. Press the key that corresponds to your printer or plotter interface: HPIB , PARALLEL (parallel port), or SERIAL (serial port). NOTE: The plotter menu is shown as an example. It will only appear if you select PLOTTER PORT . Similar interface choices will appear if you select PRINTER PORT . • If you select HPIB , the HP-IB address selection is active. Enter the HP-IB address of your printer or plotter, followed by x1 . • If you have already selected the PARALLEL [COPY] choice for the parallel-port configuration, you must also select PARALLEL in this menu in order to generate a hardcopy. 1-12 Chapter 1 Installing Your Analyzer STEP 4. Configure the Analyzer 5. If you will be using the serial port, adjust the analyzer's baud rate until it is equal to the baud rate set on the peripheral by pressing PLOTTER BAUD RATE or PRINTER BAUD RATE and the and front panel keys. NOTE: The plotter menu is shown as an example. It will only appear if you select PLOTTER PORT . You can set the analyzer to the following baud rates: • 1200 • 2400 • 4800 • 9600 • 19200 6. Also, if you will be using the serial port, you must toggle the transmission control XMIT CNTRL (handshaking protocol) until your choice of Xon/Xoff or DTR/DSR appears (equal to the transmission control set on the peripheral). The printer menu is shown as an example. It will only appear if you select PRINTER PORT . NOTE: Transmission control for plotters is set programmatically. Chapter 1 • Xon/Xoff sets transmission on/transmission off (software handshake). • DTR/DSR sets data terminal ready/data set ready (hardware handshake). 1-13 Installing Your Analyzer STEP 4. Configure the Analyzer 7. If you will be creating a plot of the data, toggle PLTR TYPE until your choice of PLOTTER or HPGL PRT appears. • Choose PLOTTER for a pen plotter. • Choose HPGL PRT for a PCL5 compatible printer.1 8. If you will be using a printer, toggle PRNTR TYPE until your printer choice1 appears. • Choose your printer type from these HP printers: ❏ ❏ THINKJET DESKJET (except for HP DeskJet 540 and Deskjet 850C) ❏ LASERJET ❏ PAINTJET ❏ DJ 540 (for use with HP DeskJet 540 and Deskjet 850C—converts 100 dpi raster information to 300 dpi raster format) • Choose EPSON-P2 for Epson-compatible printers (ESC/P2 printer control language). 1. For a current printer compatibility guide, consult the web page at http://www.hp.com/go/pcg. 1-14 Chapter 1 Installing Your Analyzer STEP 4. Configure the Analyzer 9. Press System SET CLOCK to begin setting and activating the time stamp feature so the analyzer places the time and date on your hardcopies and disk directories. 10. Press each of the following softkeys to set the date and time, followed by x1 . 11. Press ROUND SECONDS when the time is exactly as you have set it. Chapter 1 1-15 Installing Your Analyzer STEP 4. Configure the Analyzer To Configure the Analyzer for Bench Top or Rack Mount Use There are three kits available for the analyzer: • instrument front handles kit (standard: HP part number 5062-9229) • cabinet flange kit without front handles (Option 1CM: HP part number 5062-9216) • cabinet flange kit with front handles (Option 1CP: HP part number 5062-9236) 1-16 Chapter 1 Installing Your Analyzer STEP 4. Configure the Analyzer To Attach Front Handles to the Analyzer (Standard) 1. Ensure that the front handle kit is complete. NOTE: If any items are damaged or missing from the kit, contact the nearest HP sales or service office to order a replacement kit. Items within the kit (handles, flanges, screws, etc.) are not individually available. 2. Remove the side trim strips. • (2) front handles • (6) screws • (2) trim strips 3. Attach the handles to the sides of the front panel, using three screws for each handle. 4. Place the new trim strip over the screws on the handles. WARNING: If an instrument handle is damaged, you should replace it immediately. Damaged handles can break while you are moving or lifting the instrument and cause personal injury or damage to the instrument. Chapter 1 1-17 Installing Your Analyzer STEP 4. Configure the Analyzer To Attach Cabinet Flanges without Front Handles to the Analyzer (Option 1CM) 1. Ensure that the cabinet flange kit is complete. 2. Remove side trim strips. • (2) cabinet mount flanges • (6) screws 3. Attach the cabinet flanges to the sides of the front panel using three screws for each flange. 1-18 4. Remove the feet and the tilt stands before cabinet mounting the instrument. Chapter 1 Installing Your Analyzer STEP 4. Configure the Analyzer To Attach Cabinet Flanges with Front Handles to the Analyzer (Option 1CP) 1. Ensure that the cabinet flange kit with handles is complete. 2. Remove the side trim strips. • (2) cabinet mount flanges • (2) front handles • (6) screws 3. Attach the cabinet mount flanges and the handles to the sides of the front panel, using three screws per side. (Attach the flanges to the outside of the handles.) 4. Remove the feet and the tilt stands before cabinet mounting the instrument. WARNING: If an instrument handle is damaged, you should replace it immediately. Damaged handles can break while you are moving or lifting the instrument and cause personal injury or damage to the instrument. Chapter 1 1-19 Installing Your Analyzer STEP 5. Verify the Analyzer Operation STEP 5. Verify the Analyzer Operation The following procedures show you how to check your analyzer for correct operation: • viewing installed options • initiating self-test • running operator's check • testing transmission mode • testing reflection mode NOTE If the analyzer should fail any of the following tests, call the nearest HP sales or service office to determine the type of warranty you have. If repair is necessary, send the analyzer (and the EEPROM backup disk) to the nearest HP service center with a description of any failed test and any error message. Ship the analyzer using the original packaging materials. Returning the analyzer in anything other than the original packaging may result in non-warranted damage. A table listing of Hewlett-Packard sales and service offices is provided in Table 2-1 on page 2-27. NOTE The illustrations depicting the analyzer display were made using an ES model. Other analyzer displays may appear different, depending on model and options. 1-20 Chapter 1 Installing Your Analyzer STEP 5. Verify the Analyzer Operation To View the Installed Options 1. Cycle the AC power using the LINE switch, or press System FIRMWARE REVISION . SERVICE MENU 2. Locate the serial number and configuration options. Compare them to the shipment documents. Chapter 1 1-21 Installing Your Analyzer STEP 5. Verify the Analyzer Operation To Initiate the Analyzer Self-Test 1. Cycle the AC power using the LINE switch. 2. Watch for the following indications that the analyzer is operating correctly: 1-22 Chapter 1 Installing Your Analyzer STEP 5. Verify the Analyzer Operation To Run the Operator's Check 1. Connect the equipment as shown. 2. Press Preset System SERVICE MENU TESTS EXTERNAL TESTS EXECUTE TEST . Follow the prompts shown on the analyzer display and then press CONTINUE . 3. ET models only: Press EXECUTE TEST . Follow the prompts shown on the analyzer display and then press CONTINUE . 3. ES models only: Press EXECUTE TEST . Follow the prompts shown on the analyzer display and then press CONTINUE . Chapter 1 1-23 Installing Your Analyzer STEP 5. Verify the Analyzer Operation To Test the Transmission Mode 1. Connect the equipment as shown and press Preset . NOTE: The test port return cable should have low-loss characteristics to avoid a degradation in frequency response at higher frequencies. 2. To check the forward transmission mode for channel 2, press Chan 2 Meas Trans: FWD S21(B/R) or TRANSMISSN . 3. Look at the measurement trace displayed on the analyzer. It should be similar to the trace below. 4. ES models only: To check the reverse transmission mode for channel 2, press Meas Trans: REV S12 (A/R) . The measurement trace should be similar to the trace below. 1-24 Chapter 1 Installing Your Analyzer STEP 5. Verify the Analyzer Operation To Test the Reflection Mode 1. Connect the equipment as shown and press Preset . 2. Look at the measurement trace displayed on the analyzer. It should be similar to the trace below. 3. ES models only: To check the reverse reflection mode for channel 1, press Meas Refl: REV S22 (B/R) . The measurement trace should be similar to the trace shown below. 4. If you are ready to start making measurements, continue with the next chapter, “Quick Start: Learning How to Make Measurements.” Chapter 1 1-25 Installing Your Analyzer STEP 6. Back Up the EEPROM Disk STEP 6. Back Up the EEPROM Disk Description Correction constants are stored in EEPROM on the A9 controller assembly. The advantage of having an EEPROM backup disk is the ability to store all the correction-constant data to a new or repaired A9 assembly without having to rerun the correction-constant procedures. The analyzer is shipped from the factory with an EEPROM backup disk which is unique to each instrument. It is prudent to make a copy of the EEPROM backup disk so that it can be used in case of failure or damage to the original backup disk. Equipment 3.5-inch disk.......................................................................................HP 92192A (box of 10) CAUTION Do not mistake the line switch for the disk eject button. If the line switch is mistakenly pushed, the instrument will be turned off, losing all settings and data that have not been saved. EEPROM Backup Disk Procedure 1. Press Preset . 2. Insert a 3.5-inch disk into the analyzer disk drive. 3. If the disk is not formatted, press Save/Recall FILE UTILITIES FORMAT DISK . • To format a LIF disk, select FORMAT:LIF (The supplied EEPROM backup disk is LIF. The analyzer does not support LIF-HFS format.) • To format a DOS disk, select FORMAT:DOS . Press FORMAT INT DISK and answer YES at the query. 4. Press System SERVICE MENU SERVICE MODES MORE . Toggle STORE EEPR to ON. Then press Save/Recall SELECT DISK INTERNAL DISK RETURN SAVE STATE to store the correction-constants data onto floppy disk. NOTE 1-26 A default file “FILE00” is created. The file name appears in the upper left-hand corner of the display. The file type “ISTATE(E)” describes the file as an instrument-state with EEPROM backup. Chapter 1 Installing Your Analyzer STEP 6. Back Up the EEPROM Disk 5. Press FILE UTILITIES RENAME FILE ERASE TITLE . Use the front panel knob and the SELECT LETTER softkey to rename the file “FILE00” to “N12345” where 12345 represents the last 5 digits of the instrument's serial number. (The first character in the file name must be a letter.) When finished, press DONE . 6. Label the disk with the serial number of the instrument, the date, and the words “EEPROM Backup Disk.” NOTE Whenever the analyzer is returned to Hewlett-Packard for servicing and/or calibration, the EEPROM backup disk should be returned with the analyzer. This will significantly reduce the instrument repair time. 7. The EEPROM backup disk procedure is now complete. Chapter 1 1-27 Installing Your Analyzer STEP 6. Back Up the EEPROM Disk 1-28 Chapter 1 2 Quick Start: Learning How to Make Measurements 2-1 Quick Start: Learning How to Make Measurements Introduction Introduction The information and procedures in this chapter teach you how to make measurements and what to do if you encounter a problem with your analyzer. The following sections are included: • Front Panel • Measurement Procedure • Learning to Make Transmission Measurements • Learning to Make Reflection Measurements • If You Encounter a Problem NOTE 2-2 The illustrations depicting the analyzer display were made using an ES model. Other analyzer displays may appear different, depending on model and options. Chapter 2 Quick Start: Learning How to Make Measurements Analyzer Front Panel Analyzer Front Panel CAUTION Do not mistake the line switch for the disk eject button. See the figure below. If the line switch is mistakenly pushed, the instrument will be turned off, losing all settings and data that have not been saved. Figure 2-1 The Analyzer Front Panel 1. LINE switch. This switch controls AC power to the analyzer. 1 is on, 0 is off. 2. Display. This shows the measurement data traces, measurement annotation, and softkey labels. 3. Disk drive. This 3.5-inch drive allows you to store and recall instrument states and measurement results for later analysis. 4. Disk eject button. This button ejects the disk from the disk drive. 5. Softkeys. These keys provide access to menus that are shown on the display. 6. Return key. This key returns the previous softkey menu shown on the display. 7. STIMULUS function block. The keys in this block allow you to control the analyzer source's frequency, power, and other stimulus functions. 8. RESPONSE function block. The keys in this block allow you to control the measurement and display functions of the active display channel. 9. ACTIVE CHANNEL keys. The analyzer has four independent display channels. These keys allow you to select the active channel. Then any function you enter applies Chapter 2 2-3 Quick Start: Learning How to Make Measurements Analyzer Front Panel to this active channel. Notice that the light next to the current active channel’s key is illuminated. 10. The ENTRY block. This block includes the knob, the step keys, and the number pad. These allow you to enter numerical data and control the markers. You can use the numeric keypad to select digits, decimal points, and a minus sign for numerical entries. You must also select a units terminator to complete value inputs. 11. INSTRUMENT STATE function block. These keys allow you to control channel-independent system functions such as the following: • copying, save/recall, and HP-IB controller mode • limit testing • tuned receiver mode • frequency offset mode (Option 089) • test sequence function • harmonic measurements (Option 002) • time domain transform (Option 010) HP-IB STATUS indicators are also included in this block. 12. Preset key. This key returns the instrument to either a known factory preset state, or a user preset state that can be defined. Refer to the “Preset State and Memory Allocation” chapter in the Reference Guide for a complete listing of the instrument preset condition. 13. PROBE POWER connectors. These connectors (fused inside the instrument) supply power to an active probe for in-circuit measurements of AC circuits. 14. R CHANNEL connectors. (ES models only) These connectors allow you to apply an input signal to the analyzer's R channel, for frequency offset mode. 15. ES models only: PORT 1 and PORT 2. These ports output a signal from the source and receive input signals from a device under test. PORT 1 allows you to measure S12 and S11. PORT 2 allows you to measure S21 and S22. ET models only: REFLECTION and TRANSMISSION. The REFLECTION port allows you to make reflection measurements, outputting a signal from the source and receiving input signals from a device under test. The TRANSMISSION port allows you to make transmission measurements, receiving input signals from a device under test. 2-4 Chapter 2 Quick Start: Learning How to Make Measurements Measurement Procedure Measurement Procedure This is a general measurement procedure that is used throughout the guide to illustrate the use of the analyzer. Step 1. Choose measurement parameters with your test device connected • Press the Preset key to return the analyzer to a known state. • Connect your device under test (DUT) to the analyzer. CAUTION Damage may result to the DUT if it is sensitive to the analyzer's default output power level. To avoid damaging a sensitive DUT, be sure to set the analyzer's output power to an appropriate level before connecting the DUT to the analyzer. • Choose the settings that are appropriate for the intended measurement. ❏ measurement type (S11 or reflection, for example) ❏ frequencies ❏ number of points ❏ power ❏ measurement trace format • Make adjustments to the parameters while you are viewing the device response. Step 2. Make a measurement calibration Press the Cal key to begin to perform a measurement calibration using a known set of standards (a calibration kit). Error-correction establishes a magnitude and phase reference for the test setup and reduces systematic measurement errors. Step 3. Measure the device • Reconnect the device under test. • Use the markers to identify various device response values if desired. Step 4. Output measurement results • Store the measurement file to a disk. • Generate a hardcopy with a printer or plotter. Chapter 2 2-5 Quick Start: Learning How to Make Measurements Learning to Make Transmission Measurements Learning to Make Transmission Measurements This example procedure shows you how to measure the transmission response of a 125 MHz bandpass filter. The measurement parameters listed are unique to this particular test device. For further measurement examples, refer to the “Making Measurements” chapter in the User's Guide. Step 1. Choose the measurement parameters with your test device connected 1. Press the Preset key to return the analyzer to a known state. 2. Connect your test device to the analyzer as shown in Figure 2-2. Use adapters where appropriate. CAUTION Damage may result to the device under test if it is sensitive to the analyzer's default output power level. To avoid damaging a sensitive DUT, be sure to set the analyzer's output power to an appropriate level before connecting the DUT to the analyzer. Figure 2-2 Device Connections for a Transmission Measurement 3. Choose the following measurement settings: Meas Trans: FWD S21 (B/R) or TRANSMISSN Center 125 M/µ Span 125 Menu POWER Scale Ref M/µ 5 x1 RETURN AUTO SCALE 4. Look at the device response to determine if these are the parameters that you want for your device measurement. For example, if the trace is noisy you may want to increase the test port output power (which increases the analyzer input power), reduce the IF bandwidth, or add averaging. Or, to better see an area of interest, you may want to change the test frequencies. 2-6 Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Transmission Measurements Step 2. Perform a measurement calibration 1. Disconnect your test device from the analyzer. 2. Connect a “thru” between the measurement cables, as shown in Figure 2-3. Include all the adapters that you will use in your device measurement. If noise reduction techniques are needed for the measurement, the instrument's settings (reduced IF BW, and /or averaging) should be selected prior to any error-correction. Figure 2-3 Connections for a “Thru” Calibration Standard 3. Press the following keys to make a transmission response calibration: Cal CALIBRATE MENU RESPONSE THRU 4. To save the error-correction (measurement calibration), press: Save/Recall SELECT DISK 5. Next, choose from the following options: • Choose INTERNAL MEMORY if you want to save the calibration results and instrument state to the analyzer's memory. • Choose INTERNAL DISK if you want to save the calibration results and instrument state to the disk that is in the analyzer's internal disk drive. • Choose EXTERNAL DISK if you want to save the calibration results and instrument state to the disk that is in an (optional) external disk drive that is configured to the analyzer. 6. Press RETURN SAVE STATE to save the error-correction (measurement calibration). NOTE Chapter 2 Example procedures for all types of error-correction (measurement calibrations) are located in the “Calibrating For Increased Measurement Accuracy” chapter in the User's Guide. For information on the analyzer operation during error-correction (measurement calibration), refer to the “Operating Concepts” chapter in the User's Guide. 2-7 Quick Start: Learning How to Make Measurements Learning to Make Transmission Measurements Step 3. Measure the device Measuring Insertion Loss 1. Reconnect your test device as in Figure 2-2. 2. Reposition the measurement trace for the best view. This can be done by pressing Scale Ref AUTO SCALE and, if necessary, adjusting the reference level, reference position, or the scale/division. 3. Press Marker and turn the front panel knob to place the marker at a frequency of interest. Read the device's insertion loss to 0.001 dB resolution as shown in Figure 2-4. The analyzer shows the frequency of the marker location in the active entry area (upper-left corner of display). The analyzer also shows the amplitude and frequency of the marker location in the upper-right corner of the display. Figure 2-4 Example Measurement of Insertion Loss 2-8 Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Transmission Measurements Step 4. Output measurement results This example procedure shows how to output (store) measurement results to a disk. For more information on creating a hardcopy of the measurement results, refer to the "Printing, Plotting, and Saving Measurement Results" chapter in the User's Guide. CAUTION Do not mistake the line switch for the disk eject button. If the line switch is mistakenly pushed, the instrument will be turned off, losing all settings and data that have not been saved. 1. Insert a DOS- or LIF-formatted disk into the analyzer disk drive. The analyzer does not support LIF-HFS (hierarchy file system). 2. Press Save/Recall SELECT DISK . Choose INTERNAL DISK to save the measurement results to the analyzer's internal disk drive. 3. Press RETURN DEFINE DISK-SAVE . • Toggle DATA ARRAY to ON if you want to store the error-corrected data on disk with the instrument state. • Toggle RAW ARRAY to ON if you want to store the raw data (ratioed and averaged, but no error-correction) on disk with the instrument state. • Toggle FORMAT ARY to ON if you want to store the formatted data on disk with the instrument state. • Toggle GRAPHICS to ON if you want to store user graphics on disk with the instrument state. • Toggle DATA ONLY to ON if you want to only store the measurement data of the device under test. The analyzer will not store the instrument state and error-correction (measurement calibration). Therefore, the saved data cannot be retrieved into the analyzer. NOTE Toggling DATA ONLY to ON will override all of the other save options. Because this type of data is only intended for computer manipulation, the file contents of a DATA ONLY save cannot be recalled and displayed on the analyzer. • Choose SAVE USING BINARY if you want to store data in a binary format. • Choose SAVE USING ASCII if you want to store data in an ASCII format, to later read on a computer. 4. Press RETURN SAVE STATE and the analyzer saves the file with a default title. Chapter 2 2-9 Quick Start: Learning How to Make Measurements Learning to Make Transmission Measurements Measuring Other Transmission Characteristics Using the analyzer marker functions, you can derive several important filter parameters from the measurement trace that is shown on the analyzer display. Measuring 3 dB Bandwidth. The analyzer can calculate your test device bandwidth between two equal power levels. In this example procedure, the analyzer calculates the −3 dB bandwidth relative to the center frequency of the filter. 1. Press Marker and turn the front panel knob to move the marker to the center frequency position of the filter passband. An alternative method is to press Marker Search SEARCH: MAX which should put you very close to the center of the passband. You can also position the marker by entering a frequency location: for example, press 125 M/µ . 2. Press Marker MKR ZERO to zero the delta marker magnitude and frequency (this sets the delta marker reference). The −3 dB points will be relative to this marker. The softkey label changes to MKR ZERO ∆ REF= ∆ reference point is the small ∆ symbol. to show you that the delta 3. Press Marker Search to enter the marker search mode. 4. Toggle WIDTHS to ON. The analyzer calculates the −3 dB bandwidth, the center frequency and the Q (quality factor) of the test device and lists the results in the upper-right corner of the display. Markers 3 and 4 indicate the location of the −3 dB points, as shown in Figure 2-5. Figure 2-5 2-10 Example Measurement of 3 dB Bandwidth Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Transmission Measurements 5. Press WIDTH VALUE and enter −6 x1 . The analyzer now calculates the bandwidth between −6 dB power levels. 6. Press Marker Chapter 2 all OFF when you are finished with this measurement. 2-11 Quick Start: Learning How to Make Measurements Learning to Make Transmission Measurements Measuring Out-of-Band Rejection. 1. Press MARKER 1 . The marker appears where you placed it during the bandwidth measurement. 2. Press MKR ZERO Marker Search SEARCH: MIN . The marker automatically searches for the minimum point on the trace. The frequency and amplitude of this point, relative to the delta symbol in the center of the filter passband, appear in the upper-right corner of the display. This value is the difference between the maximum power in the passband and the power in the rejection band, that is, one of the peaks in the rejection band. Figure 2-6 Example Measurement of Out-of-Band Rejection NOTE You can use the marker search mode to search the trace for the maximum point or for any target value. The target value can be an absolute level (for example, −3 dBm) or a level relative to the location of the small delta symbol (for example: −3 dB from the center of the passband). 3. If your measurement needs some noise reduction, you can reduce the IF bandwidth or add averaging. • To reduce the IF bandwidth, press Avg IF BW . • To add averaging, press Avg . Toggle AVERAGING to ON. 2-12 Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Transmission Measurements Measuring Passband Flatness or Ripple. Passband flatness (or ripple) is the variation in insertion loss over a specified portion of the passband. Continue with the following steps to measure passband flatness or ripple. and 1. Press Save/Recall (if necessary, scroll to the desired file using the panel keys). Press RECALL STATE to recall the error-corrected transmission measurement that has no markers engaged. front 2. Press Marker and turn the front panel knob to move marker 1 to the left edge of the passband. 3. Press ∆MODE MENU reference point. ∆ REF=1 to change the marker 1 position to the delta 4. Press MARKER 2 and turn the front panel knob to move marker 2 to the right edge of the passband. 5. Press Marker Fctn MARKER MODE MENU . Toggle STATS to ON. The analyzer calculates the mean, standard deviation, and peak-to-peak variation between the ∆ reference marker and the active marker, and lists the results in the upper-right corner of the display. The passband ripple is automatically shown as the peak-to-peak variation between the markers. Figure 2-7 Chapter 2 Example Measurement of Passband Flatness or Ripple 2-13 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Learning to Make Reflection Measurements This example procedure shows you how to measure the reflection response of a 125 MHz bandpass filter. The measurement parameter values listed are unique to this particular test device. For further measurement examples, refer to the "Making Measurements" chapter in the User's Guide. NOTE Reflection measurements monitor only one port of a test device. When a test device has more than one port, you must ensure that the unused port(s) are terminated in their characteristic impedance (for example, 50Ω or 75Ω). If you do not terminate unused ports, reflections from these ports will cause measurement errors. Figure 2-8 on page 2-15 illustrates two ways to terminate an unused device port with the proper characteristic impedance. The signal reflected from the device under test is measured as a ratio of the reflected energy versus the incident energy. It can be expressed as reflection coefficient, return loss, or standing-wave-ratio (SWR). These measurements are mathematically defined as follows: reflection coefficient (Γ) = reflected voltage / incident voltage = S11 or S22 (magnitude and phase) magnitude of reflection coefficient (ρ) = |Γ| return loss (dB) = −20 log (ρ), where (ρ) = |Γ| standing-wave-ratio (SWR) = V maximum / V minimum = (1 + ρ) / (1 − ρ) 2-14 Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Step 1. Choose measurement parameters with your test device connected 1. Press the Preset key to return the analyzer to a known state. 2. Connect your test device as shown in Figure 2-8. If using a load, make sure it has the correct characteristic impedance. Damage may result to the device under test if it is sensitive to the analyzer's default output power level. To avoid damaging a sensitive DUT, be sure to set the analyzer's output power to an appropriate level before connecting the DUT to the analyzer. CAUTION Figure 2-8 Connections for Reflection Measurements 3. Choose the following measurement parameters: Meas Refl: FWD S11 (A/R) or REFLECTION Center 125 M/µ Span 100 Menu POWER Scale Ref M/µ 5 x1 RETURN AUTO SCALE 4. Look at the device response to determine if these are the measurement parameters that you want. For example, if the trace is noisy you may want to increase the input power, reduce the IF bandwidth, or add averaging. Or, to better see an area of interest, you may want to change the test frequencies. Chapter 2 2-15 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Step 2. Make a measurement calibration Follow these instructions to perform an S11 or reflection 1-port error correction: 1. Select a calibration kit that is appropriate to your device under test. Press Cal CAL KIT SELECT CAL KIT . Choose the calibration kit that is appropriate to your test device by pressing the appropriate softkey. For example, if your test device uses type-N 50Ω connectors, press N 50Ω . If your test device uses 7-mm connectors, press 7mm , and so on. 2. Press RETURN twice, CALIBRATE MENU S11 1-PORT or REFLECTION 1-PORT . 3. Follow the prompts shown on the analyzer display to connect and measure an open, short, and load on PORT 1 or the REFLECTION port. Any choice of male/female in the calibration process should always be made for the sex that represents the test port. For example, if the test port had a male, type-N connector, you would connect the female, type-N calibration device. But when you follow the prompts on the analyzer to measure a short calibration standard, you would select SHORT (M) , or the sex that represents the test port. CAUTION To ensure an accurate error correction, you must connect the calibration standards to the adapters or cables that you will include in the actual device measurement. NOTE If a mistake is made, standards can be measured more than once before pressing DONE 1-PORT CAL . Only the last measurement data is used. Figure 2-9 Connections for an S11 or Reflection 1-Port Error-Correction 4. Press DONE 1-PORT CAL after measuring the three standards. 5. Press Save/Recall . 6. Press SAVE STATE to complete the process. 2-16 Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Step 3. Measure the device Measuring Return Loss. 1. Connect your device to PORT 1 or the REFLECTION port. 2. Press Scale Ref AUTO SCALE to reposition the trace. 3. Press Marker to read the return loss from the analyzer display as shown in Figure 2-10. The device response indicates that the filter and the analyzer impedances are better matched within the frequency range of the filter passband than outside the passband. That is, the reflected signal is smaller within the filter passband than outside the passband. In terms of return loss, the value within the passband is larger than outside the passband. A large value for return loss corresponds to a small reflected signal just as a large value for insertion loss corresponds to a small transmitted signal. Figure 2-10 Example Measurement of Return Loss Chapter 2 2-17 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Step 4. Output measurement results This step in the procedure shows you how to output the measurement results to a printer. For in-depth information on creating a hardcopy of the measurement results, refer to the “Printing, Plotting, and Saving Measurement Results” chapter in the User's Guide. 1. Connect a printer to the analyzer as described in “To Configure the Analyzer with Printers or Plotters” on page 1-11. 2. Press Display MORE TITLE ERASE TITLE and then create a title for the measurement, as shown in Figure 2-11: • Use an optional keyboard to type the title, or • Use the front panel knob and the softkey menu to select each letter of the title. 3. Press DONE when you finish creating the measurement title. The title appears on the upper-left corner of the analyzer display. 4. Press Local SYSTEM CONTROLLER to set up the analyzer as the controller. If you are using an HP-IB printer, ensure that there is not another controller on the bus. (Note that this step is not required when using parallel or serial printers.) 5. Press Copy NOTE PRINT MONOCHROME to create a black and white hardcopy. If you encounter a problem when printing a hardcopy, refer to “To Configure the Analyzer with Printers or Plotters” on page 1-11. Figure 2-11 Example Measurement Title 2-18 Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Measuring Other Reflection Characteristics You can derive several important filter parameters from the measurement shown on the analyzer display. The following set of procedures is a continuation of the previous reflection measurement procedure. Measuring Reflection Coefficient 1. Press Save/Recall RECALL STATE to recall the calibrated reflection measurement that you saved earlier in this procedure. 2. Press Format LIN MAG Scale Ref AUTO SCALE so the analyzer shows the same data in terms of reflection coefficient, as shown in Figure 2-12. The units “mU” displayed on the analyzer are “milli-units,” where “units” or “U” is used to indicate that the parameter is unitless (as opposed to dB in log magnitude format). For example, 200 mUnits = 0.2. Figure 2-12 Example Reflection Coefficient Measurement Trace Chapter 2 2-19 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Measuring Standing Wave Ratio (SWR) Press Format SWR Scale Ref AUTO SCALE so the analyzer shows the same data in terms of standing-wave-ratio (SWR), as shown in Figure 2-13. Now the analyzer shows the measurement data in the unitless measure of SWR where SWR = 1 (perfect match) at the bottom of the display. Figure 2-13 Example Standing-Wave-Ratio Measurement Trace 2-20 Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Measuring S11 and S22 or Reflection in a Polar Format. 1. Press Format POLAR . 2. Press Scale Ref AUTO SCALE to reposition the trace, as shown in Figure 2-14. The analyzer shows the results of an S11 or reflection measurement with each point on the polar trace corresponding to a particular value of both magnitude and phase. The center of the circle represents a coefficient (Γ) of 0, (that is, a perfect match or no reflected signal). The notation 2U FS or 2 units full scale indicates that the outermost circumference of the scale shown in Figure 2-14 represents ρ = 2.00, or 200% reflection. The phase angle is read directly from this display. The 3 o'clock position corresponds to zero phase angle, (that is, the reflected signal is at the same phase as the incident signal). Phase differences of 90°, 180°, and −90° correspond to the 12 o'clock, 9 o'clock, and 6 o'clock positions on the polar display, respectively. 3. Press Marker Fctn MARKER MODE MENU POLAR MKR MENU . 4. Turn the front panel knob to position the marker at any desired point on the trace, then read the frequency, linear magnitude and phase in the upper right-hand corner of the display. • Choose LIN MKR if you want the analyzer to show the linear magnitude and the phase of the marker. • Choose LOG MKR if you want the analyzer to show the logarithmic magnitude and the phase of the active marker. This is useful as a fast method of obtaining a reading of the log-magnitude value without changing to log-magnitude format. • Choose Re/Im MKR if you want the analyzer to show the values of the marker as a real and imaginary pair. NOTE You can also enter the frequency of interest, from either the numeric keypad or the optional attached keyboard, and read the magnitude and phase at that point. Figure 2-14 Example S11 or Reflection Measurement Trace in Polar Format Chapter 2 2-21 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Measuring S11 and S22 or Reflection in a Smith Chart Format. • Measuring Impedance The amount of power reflected from a device is directly related to the impedance of the device and the measuring system. Each value of the reflection coefficient (Γ) uniquely defines a device impedance; Γ = 0 only occurs when the device and analyzer impedance are exactly the same. The reflection coefficient for a short circuit is: Γ = 1 ∠ 180°. Every other value for Γ also corresponds uniquely to a complex device impedance, according to the equation: ZL = [(1 + Γ) / (1 −Γ)] × Z0 where ZL is your test device impedance and Z0 is the measuring system's characteristic impedance (usually 50Ω or 75Ω). 1. Press Format SMITH CHART Scale Ref AUTO SCALE . 2. Press Marker Fctn MARKER MODE MENU SMITH MKR MENU and turn the front panel knob to read the resistive and reactive components of the complex impedance at any point along the trace, as shown in Figure 2-15. Here the complex impedance is 6.4729 – j7.5569 Ω . This is the default Smith chart marker. The marker annotation also gives the series inductance or capacitance (132.87 pF in this example). The complex impedance is capacitive in the bottom half of the Smith chart display and is inductive in the top half of the display. • Choose LIN MKR if you want the analyzer to show the linear magnitude and the phase of the reflection coefficient at the marker. • Choose LOG MKR if you want the analyzer to show the logarithmic magnitude and the phase of the reflection coefficient at the active marker. This is useful as a fast method of obtaining a reading of the log magnitude value without changing to log magnitude format. • Choose Re/Im MKR if you want the analyzer to show the values of the reflection coefficient at the marker as a real and imaginary pair. • Choose R+jX MKR (the default marker format) to show the real and imaginary parts of the device impedance at the marker. Also shown is the equivalent series inductance or capacitance (the series resistance and reactance, in ohms). 2-22 Chapter 2 Quick Start: Learning How to Make Measurements Learning to Make Reflection Measurements Figure 2-15 Example Impedance Measurement Trace • Measuring Admittance To change the display to an inverse Smith chart graticule and the marker information to read admittance, press G+jB MKR . As shown in Figure 2-16, the marker reads admittance data in the form G+jB, where G is conductance and B is susceptance, both measured in units of Siemens (equivalent to mhos: the inverse of ohms). Also shown is the equivalent parallel capacitance or inductance. Figure 2-16 Example Admittance Measurement Trace Chapter 2 2-23 Quick Start: Learning How to Make Measurements If You Encounter a Problem If You Encounter a Problem If you have difficulty when installing or using the analyzer, check the following list of commonly encountered problems and troubleshooting procedures. If the problem that you encounter is not in the following list, refer to additional troubleshooting sections in the Service Guide. Power-Up Problems If the analyzer display does not light: • Check that the power cord is fully seated in both the main power receptacle and the analyzer power module. • Check that the AC line voltage selector switch is in the appropriate position (230 V/115 V) for your available power supply. • Check that the analyzer AC line fuse is not open. WARNING For continued protection against fire hazard, replace the fuse with the same type and rating. Refer to Figure 2-17 to remove the fuse from the power module. You can use a continuity light or an ohmmeter to check the fuse. An ohmmeter should read very close to zero ohms if the fuse is good. For 115V operation, use a 5A 125V TD fuse (HP part number 2110-1059). For 230V operation, use a T 4A 250V fuse (HP part number 2110-0734). • Contact the nearest Hewlett-Packard office for service, if necessary. A list of Hewlett-Packard sales and service offices is provided in Table 2-1 on page 2-27. Figure 2-17 Line Fuse Removal and Replacement 2-24 Chapter 2 Quick Start: Learning How to Make Measurements If You Encounter a Problem If the display lights, but the ventilation fan does not start: ❏ Check that the fan is not obstructed. To check the fan, follow these steps: 1. Switch the LINE power to the off position. 2. Check that the fan blades are not jammed. ❏ Contact the nearest Hewlett-Packard office for service, if necessary. A list of Hewlett-Packard sales and service offices is provided in Table 2-1 on page 2-27. Data Entry Problems If the data entry controls (keypad, knob, arrow keys) do not respond: ❏ Check that the ENTRY OFF function is not enabled. The ENTRY OFF function is enabled after you press the Entry Off key. To return to normal entry mode, press any function key that has a numeric parameter associated with it, for example, Start . ❏ Check that none of the keys are stuck. ❏ Check that the selected function key accepts data. For example, Scale Ref accepts data, but System does not. ❏ Check that the analyzer's "R" HP-IB STATUS light is not illuminated. If the analyzer's "R" HP-IB STATUS light is illuminated, a test sequence may be running, or a connected computer controller may be sending commands or instructions to, or receiving data from, the analyzer. Press Local if you want to return to LOCAL control. If the parameter you are trying to enter is not accepted by the analyzer: ❏ Ensure that you are not attempting to set the parameter greater than or less than its limit. Refer to the User's Guide for parameter limits. No RF Output If there is no RF signal at the front-panel port: ❏ Check that the signal at the test port is switched on. 1. Press Power and toggle SOURCE PWR to ON. NOTE On ES models, it is possible to set the source power to come from PORT 2 instead of PORT 1, so you must check the power at the correct port. With factory preset, the power comes from PORT 1. ❏ If you are applying external modulation (AM) to the analyzer, check the external modulating signal or external gate/trigger signals for problems. Chapter 2 2-25 Quick Start: Learning How to Make Measurements If You Encounter a Problem CAUTION If the error message: CAUTION: OVERLOAD ON INPUT X, POWER REDUCED appears on the analyzer display, too much source power is being applied at the input. In such a case, the input power will need to be reduced before the source power will remain on. ❏ If phase-lock error messages appear on the analyzer display, check that the front panel jumper is secure on the R CHANNEL connectors. If the jumper is secure and the error messages still appear, contact your nearest Hewlett-Packard office for service. A list of Hewlett-Packard sales and service offices is provided in Table 2-1 on page 2-27. 2-26 Chapter 2 Quick Start: Learning How to Make Measurements If You Encounter a Problem Table 2-1 Hewlett-Packard Sales and Service Offices UNITED STATES Instrument Support Center Hewlett-Packard Company (800) 403-0801 EUROPEAN FIELD OPERATIONS Headquarters Hewlett-Packard S.A. 150, Route du Nant-d’Avril 1217 Meyrin 2/ Geneva Switzerland (41 22) 780.8111 France Hewlett-Packard France 1 Avenue Du Canada Zone D’Activite De Courtaboeuf F-91947 Les Ulis Cedex France (33 1) 69 82 60 60 Germany Hewlett-Packard GmbH Hewlett-Packard Strasse 61352 Bad Homburg v.d.H Germany (49 6172) 16-0 Great Britain Hewlett-Packard Ltd. Eskdale Road, Winnersh Triangle Wokingham, Berkshire RG41 5DZ England (44 118) 9696622 INTERCON FIELD OPERATIONS Headquarters Hewlett-Packard Company 3495 Deer Creek Rd. Palo Alto, CA 94304-1316 USA (415) 857-5027 Japan Hewlett-Packard Japan, Ltd. 9-1 Takakura-Cho, Hachioji Tokyo 192, Japan (81 426) 60-2111 Australia Hewlett-Packard Australia Ltd. 31-41 Joseph Street Blackburn, Victoria 3130 (61 3) 895-2895 Canada Hewlett-Packard (Canada) Ltd. 17500 South Service Road Trans-Canada Highway Kirkland, Quebec H9J 2X8 Canada (514) 697-4232 Singapore Hewlett-Packard Singapore (Pte.) Ltd. 150 Beach Road #29-00 Gateway West Singapore 0718 (65) 291-9088 Taiwan Hewlett-Packard Taiwan 8th Floor, H-P Building 337 Fu Hsing North Road Taipei, Taiwan (886 2) 712-0404 China China Hewlett-Packard Co. 38 Bei San Huan X1 Road Shuang Yu Shu Hai Dian District Beijing, China (86 1) 256-6888 Chapter 2 2-27 Quick Start: Learning How to Make Measurements If You Encounter a Problem 2-28 Chapter 2 Index Numerics 3 dB bandwidth measuring, 2-10 6 dB bandwidth measuring, 2-11 H Hewlett-Packard Sales and Service Offices, 2-27 high stability frequency reference configuration, 1-10 A active channel keys location, 2-3 admittance measuring, 2-23 analyzer configuration, 1-9–1-19 attaching cabinet flanges with front handles, 1-19 attaching cabinet flanges without front handles, 1-18 attaching front handles, 1-17 for bench top use, 1-16 for rack mount use, 1-16 option 1D5, 1-10 standard, 1-10 with printers or plotters, 1-11 I impedance measuring, 2-22 insertion loss measuring, 2-8 installation, 1-2 instrument state function block keys, 2-4 B backing up EEPROM disk, 1-26 bench top configuration, 1-16 C connectors probe power source, 2-4 R channel, 2-4 D definitions magnitude of reflection coefficient, 2-14 reflection coefficient, 2-14 return loss (dB), 2-14 standing-wave-ratio (SWR), 2-14 disk drive location, 2-3 disk eject button, 2-3 display location, 2-3 E EEPROM backup disk, 1-26 electrical and environmental requirements, 1-7 entry block location, 2-4 F front panel, 1-5, 2-3 Index L line switch, 2-3 location active channel keys, 2-3 disk drive, 2-3 disk eject button, 2-3 display, 2-3 entry block, 2-4 instrument state function block keys, 2-4 line switch, 2-3 PORT 1, 2-4 PORT 2, 2-4 Preset key, 2-4 probe power source connectors, 2-4 R channel connectors, 2-4 REFLECTION port, 2-4 response function block keys, 2-3 Return key, 2-3 softkeys, 2-3 stimulus function block keys, 2-3 TRANSMISSION port, 2-4 M making measurements, 2-1–2-23 measurement procedure, 2-5 choosing measurement parameters, 2-5 making a measurement calibration, 2-5 measuring a device, 2-5 outputting measurement results, 2-5 measuring insertion loss with marker functions, 2-10 O operation, 1-20–1-25 installed options, 1-21 operator’s check, 1-23 self-test, 1-22 testing reflection mode, 1-25 testing transmission mode, 1-24 operator’s check, 1-23 out-of-band rejection measuring, 2-12 P parts list parts received, 1-4 passband flatness measuring, 2-13 passband ripple measuring, 2-13 plotter configuration, 1-11 polar format measuring, 2-21 PORT 1 location, 2-4 PORT 2 location, 2-4 Preset key location, 2-4 printer configuration, 1-11 probe power connectors location, 2-4 problems, data entry, 2-25 controls do not respond, 2-25 parameters not accepted, 2-25 problems, power-up, 2-24–2-25 display does not light, 2-24 display lights but fan does not start, 2-25 problems, RF output, 2-25 no RF signal at front panel port, 2-25 R R channel connectors location, 2-4 rack mount configuration, 1-16 rear panel, 1-6 reflection measurements, 2-14–2-23 admittance, 2-23 choosing measurement parameters, 2-15 impedance, 2-22 making a measurement calibration, 2-16 measuring in polar format, 2-21 1 Index measuring in smith chart format, 2-22 measuring reflection coefficient, 2-19 measuring return loss, 2-17 measuring standing wave ratio (SWR), 2-20 measuring the device, 2-17 outputting measurement results, 2-18 REFLECTION port location, 2-4 requirements electrical and environmental, 1-7 response function block keys location, 2-3 Return key, location, 2-3 return loss measuring, 2-17 V verifying the shipment, 1-3 S Sales and Service Offices, 2-27 shipment, verifying, 1-3 smith chart, 2-22 smith chart format measuring, 2-22 softkeys, location, 2-3 standard analyzer configuration, 1-10 standing wave ratio (SWR) measuring, 2-20 stimulus function block keys location, 2-3 T transmission measurements, 2-6–2-13 3 dB bandwidth, 2-10 6 dB bandwidth, 2-11 choosing the measurement parameters, 2-6 insertion loss, 2-8 making a measurement calibration, 2-7 measuring insertion loss with marker functions, 2-10 measuring the device, 2-8 out-of-band rejection, 2-12 outputting measurement results, 2-9 passband flatness, 2-13 passband ripple, 2-13 TRANSMISSION port location, 2-4 troubleshooting, 2-24–2-26 2 Index ">
Advertisement
Key features
- Transmission measurements
- Reflection measurements
- Error correction (measurement calibration)
- Storing and retrieving measurement results
- Generating hardcopy with a printer or plotter
Frequently asked questions
The HP 8753 Network Analyzer can make a variety of measurements, including transmission, reflection, and other characteristics of networks and devices.
Error correction is a process that is used to reduce measurement errors by establishing a magnitude and phase reference for the test setup. This is done using a known set of standards (a calibration kit).
Measurement results can be stored on a disk, or in the analyzer's internal memory.
Yes, you can generate a hardcopy of the measurement results using a printer or plotter.