Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Dyna-Glo

®

Delux Propane

Gas-Fired Radiant Heater

Description

Dyna-Glo Delux Model RA125LPDGD heater is a 125,000 BTU/Hr construction heater.

This heater uses propane gas for combustion. It is primarily intended for temporary heating of well-ventilated buildings under construction, alteration or repair. This heater should be utilized in sheltered, well-ventilated areas, but never in occupied dwellings.

Unpacking

1. Remove heater, accessories and all

C US

C US damage that may have occurred during hardware from the shipping carton.

NOTE: Save the box and packaging materials for future use. After unpacking unit, inspect carefully for any transit. Check for loose, missing or damaged parts. Shipping damage claim must be filed with carrier.

GHP Group, Inc.

8280 Austin Avenue

Morton Grove, IL 60053

Specifications

Figure 1 – Model

RA125LPDGD

Model BTU/Hr

Fuel Consumption Manifold

Maximum Pressure

Inlet Gas Supply

Pressure

Dimensions

Ignitor Gap Weight (Lbs) L x W x H (in.)

RA125LPDGD 50,000 to

16.3 x 29.8

125,000

Fuel Type – Propane Only

SIZE AND CAPACITY OF PROPANE

GAS CYLINDERS

Temperature

(°F) at Tank

No. of Tanks Needed

50,000 BTU/Hr 100,000 BTU/Hr

32 1 2

20 1 2

10

0

-10

-20

1

1

2

2

3

3

Use Larger

Tank

Use Larger

Tank

NOTE: Chart above shows number of

100 pound tanks needed to operate this heater at a given temperature.

Less gas is vaporized at lower temperatures. You may need two or more 100 pound tanks, or one larger tank in colder weather. Your local propane gas dealer will help you select the proper supply system.

5.77 lbs/hr 11” W.C. Min. 5 psi 0.19“ 20.3 (heater) 16.3 x

Max. Bottle Pressure

Ignition Type – Piezo

General Safety Information

Make sure you read and thoroughly understand these safety and operating instructions. Keep these instructions for future reference. They are your guides to safe and proper operation of this heater. hazardous situation which, if not avoided, WILL result in death or serious injury.

Indicates an imminently hazardous situation which, if not avoided, COULD result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.

Indicates a potentially

Minimum Operating Temp. – -20°F (-29°C)

Always turn off heater at control knob and then close LP cylinder when not in use.

Do not operate this heater until you have read, and thoroughly understand these safety and operating instructions. Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, property loss or damage from the hazards of fire, explosion, burns, or electrical shock. Only persons who can read and understand these instructions should use or service this heater. Not for residential, household or recreational vehicle use. Please read this manual.

Consumer: Retain this manual for future reference.

O

L

P

A

E

S

I

S

H

E

N

G

L

N

Ç

A

I

S

F

R

A

Rev 2012-06-08 Printed in China

PROFESSIONAL GRADE

RA125LPDGD

Dyna-Glo Delux Operating Instructions and Parts Manual

Dyna-Glo

®

Delux Propane Gas-Fired

Radiant Heater

I

S

H

E

N

G

L

General Safety Information

(Continued)

General Hazard

WarninG: Failure to comply with the precautions and instructions provided with this heater, can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and / or electrical shock.

Only persons who can understand and follow the instructions should use or service this heater.

Fire, burn, inHalation, and explosion Hazard: Keep solid combustibles, such as building materials, paper, or cardboard, a safe distance away from the heater as recommended by the instructions. Never use the heater in spaces which do or may contain volatile or airborne combutibles, or products such as gasoline, solvents, paint thinner, dust particles or unknown chemicals.

For outdoor and indoor use with proper ventilation. Not for home or recreational vehicle use.

1. This heater has been designed as a construction heater in accordance with CSA 2.14, ANS Z83.7. Other standards govern the use of fuel, gases and heating products for specific uses.

Your local authority can inform you of these. The primary purpose of these construction heaters are to provide temporary heating of buildings under construction, alteration, or repair.

When properly used, the heater provides safe economical heating.

Products of combustion are vented into the heated area.

2. Keep solid combustibles, such as building materials, paper or cardboard a safe distance away from the heater as recommended by the instructions in this manual (at least 6 feet away from sides and 5 feet from top of heater).

Never use the heater in spaces which do or may contain volatile or airborne combustibles or products such as gasoline, solvents, paint thinner, dust particles, or unknown chemicals.

3. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Do not move heater when in use OR for at least

35 minutes after using.

4. Keep combustible materials, such as furniture, pillow, bedding, papers, clothes and curtains at least 6 feet away from sides and 5 feet from top of this heater.

Carbon Monoxide poisoning may lead to death! Some people are more affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be operating properly or the area may not be sufficiently ventilated. Get fresh air at once! Have heater serviced.

5. Do not operate any heater with a damaged regulator or after the heater malfunctions, or has been dropped or damaged in any manner.

Return heater to an authorized service facility for examination, or mechanical adjustment, or repair.

6. This heater should be utilized in sheltered, well-ventilated areas, but never in occupied dwellings, in living areas or sleeping areas.

7. Do not use this heater in a residential or household area. If stored indoors, detach and leave the LP cylinder outdoors.

8. Never replace the regulator with any regulator other than the factory suggested replacement.

9. Do not insert or allow any foreign objects to enter any ventilation or exhaust opening as this may cause a fire, or damage to the heater.

Carefully install and always use great care when operating this heater. Be sure to research and follow all local ordinances and codes. In the absence of local codes, with the Standard for the Storage and

Handling of Liquefied Petroleum Gases,

ANSI/NFPA 58 and the Natural Gas and

Propane Installation Code, CSA B149.1.

The heater is designed and approved for use as a construction heater in accordance with Standard CSA 2.14b, ANS

Z83.7b.

CHECK WITH YOUr LOCAL FIrE SAFETY

AUTHOrITY IF YOU HAvE qUESTIONS

ABOUT APPLICATIONS. Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.

California proposition 65 Warning:

Fuels used in gas or oil fired appliances and the products of combustion of such fuels, contain chemicals known to the

State of California to cause cancer, birth defects or other reproductive harm. This product contains chemicals, including lead and lead compounds, known to the state of California to cause cancer, birth defects or other reproductive harm.

Wash hands after handling.

Never let children operate or allowed near any heater. Never leave heater operating and unattended.

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com

2

Dyna-Glo Delux Operating Instructions and Parts Manual

Model RA125LPDGD

General Safety Information

(Continued)

10. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause a fire or injury to persons.

11. Provide adequate ventilation. Before using heater, provide at least a 3.0 square foot opening of fresh, outside air for every 100,000 BTU/Hr rating.

12. Do not modify or alter this heater in any way or operate any heater that has been modified from its original state.

13. It is hard to anticipate every use which may be made of the heater.

Check with your local fire safety authority if you have any questions about heater application.

14. Be sure heater is on a solid and level surface.

Propane Gas: Propane gas is odorless.

An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, this odor may fade in time. Propane gas may be present in the area even though no odor is detected.

15. Use only propane gas. Do not attempt to use natural gas.

16. Keep appliance clear and free from combustible materials, gasoline, paint thinner, and other flammable vapors and liquids. Dust is combustible. Do not use heaters in areas with high dust content.

17. Check heater for damage before each use. Do not use damaged heater.

Minimum heater clearance from combustibles:

Sides: 6 feet Top: 5 feet

Floor: Combustible - Not for use

on finished floors

18. The heater, other than a heater with an integral propane gas cylinder, must be located at least (i) 6 ft. (1.83 m) in the U.S.; or (ii) 10 ft. (3 m) in Canada, from any propane gas cylinder.

19. The propane cylinder supply system must be arranged to provide for vapor withdrawal from the operating cylinder.

20. Blower or radiant type heaters shall not be directed toward any propane gas cylinder within 20 feet (6 m).

21. Check hose before each use of heater. Do not use if hose is cut or damaged. Replace with hose specified by manufacturer.

22. The heater is not intended for use on finished floors. Warping or other damage may occur.

23. Place heater away from any breezes or drafts. Keep away from dripping water or rain.

24. Keep small children and animals away from the heater.

25. Always wear gloves when handling the heater to prevent injury.

26. Never attach ductwork to heater.

27. Use only original replacement parts.

This heater must use design specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injury.

Assembly

1. Provide propane gas supply only.

2. Connect heater to a proper gas supply using the supplied regulator, and turn knob on LP cylinder on.

3. Wait 5 minutes for any gas to clear.

Smell for gas; if you do not smell gas, heater is ready to operate.

Never use an open flame to check for a leak. Apply 50/50 mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Operation

This heater should only be used with a tank that has a vapor withdrawal system. Refer to the Standard of

Storage and Handling of Liquefied

Petroleum Gas, ANSI/NFPA 58, Chapter

5. Your local fire department or library will have this information.

TO START HEATER

1. Follow all of the safety, ventilation and installation instructions previously noted in this manual.

2. Always be sure to place the heater on a stable and level surface while the heater is in operation. Be sure that no strong winds blow into the ends of the

3. Turn control knob clockwise to “OFF” position.

4. Turn LP gas supply valve on.

5. Depress heater control knob and turn

COUNTERCLOCKWISE to “(IGN)

LOW” position to light burner.

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com

3

PROFESSIONAL GRADE

I

S

H

E

N

G

L

RA125LPDGD

Dyna-Glo Delux Operating Instructions and Parts Manual

Dyna-Glo

®

Delux Propane Gas-Fired

Radiant Heater

I

S

H

E

N

G

L

Operation (Continued)

6. If burner does not light, turn heater control knob to “OFF” position and repeat step 5. Keep control knob depressed for approximately 10 to 15 seconds, then release control knob.

7. If burner flame goes out, wait 5 minutes then repeat steps 5 and 6.

8. With burner operating, the control knob may be turned

COUNTERCLOCKWISE to desired heating level between

“LOW,” “MED,” and “HIGH.”

TO CONNECT OR DISCONNECT

PROPANE TANK

Turn heater gas valve knob and gas tank valve to OFF position.

To connect gas line fitting to propane tank valve, turn fitting COUNTER-

CLOCKWISE .

To disconnect, turn fitting CLOCKWISE

. Protect this fitting when disconnected from tank.

Knob

Control Valve

Figure 3 – RA125LPDGD Part Identification

LEAK CHECKING

1. With heater gas valve knob still in

OFF position, turn ON tank valve and check for leaks with soap solution.

Check all connections with a 50/50 soap and water solution to be sure they are tight and leak proof. Never use a flame to check for gas leaks.

2. The installation of your heater must meet all local codes and/or gas utility requirements, or in the absence of local codes, with the National Fuel

Code ANSI Z223.1.

TO SHUT DOWN HEATER

1. Firmly close the propane gas supply valve.

2. Shut off the main burner valve, being sure to wear a glove for protection.

Turn the main burner handle all the way to the OFF position.

Shell

Emitter

Spark Plug

Thermocouple

Nozzle Burner

Tubing Outlet Assembly

Nozzle Burner Bracket

Flame Shield

Base

Regulator

TO RESTART HEATER

1. Wait five minutes for heater to cool.

2. Follow steps in TO START HEATER section.

running heater below specified gas pressure may cause flashback. During flashback, the burner flame is mostly yellow. The flame will burn inside the burner tube causing a roaring noise. If flashback occurs, turn heater off. After burner tube cools off, restart heater.

vENTILATION

A three square foot opening of fresh outside air for each 100,000 BTU / Hr of heater output must be provided to operate each heater safely. If the proper ventilation air is not provided, carbon monoxide poisoning can occur. Always be sure that the proper ventilation is being provided before starting this heater.

FRESH OUTSIDE AIR OPENING

REQUIREMENTS

Heater size Square foot opening

125,000 BTU 3.5

read and understand all of the warnings in the General Safety Information pages of this manual. They are essential to the safe operation of this heater. Be sure to follow all local codes when operating this heater.

Be sure to leak test all fittings and pipe connections after installation or repairs.

Use a 50/50 mixture of liquid dish soap and water. Bubbles forming reveal a leak.

You must repair all leaks at once!

Maintenance

Never attempt to service heater while it is connected to propane supply, operating or hot. Severe burns can occur.

1. Always keep heater clean. The flow of combustion and ventilation air cannot be obstructed.

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com

4

Dyna-Glo Delux Operating Instructions and Parts Manual

Model RA125LPDGD

Maintenance (Continued)

2. Inspect heater before each use. Check connections for leaks. Apply a 50/50 solution of dish soap and water.

Bubbles forming show a leak that must be corrected. Correct leaks at once.

3. Inspect regular hose assembly before each use. If hose is highly worn or cut, replace with hose specified by manufacturer.

4. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

5. Have heater inspected yearly by a qualified service person.

6. Installation must conform with local codes or, in the absence of local codes, with the Standard for the

Storage and Handling of Liquefied

Petroleum Gases, ANSI/NFPA 58 and the Natural Gas and Propane

Installation Code, CSA B149.1.

STORAGE

Disconnect heater from propane gas supply.

1. The heater is to be stored indoors.

The connection between the propane supply cylinder(s) and the heater must be disconnected and the cylinders removed from the heater and stored in accordance with Standard for the

Storage and Handling of Liquefied

Petroleum Gases, ANSI/NFPA 58 and

CSA B149.1, Natural Gas and Propane

Installation Code.

2. Place plastic cover over brass fitting on inlet connector.

3. Store in a dry, clean, safe place.

4. When taking the heater out of storage, always check inside the heater. Small animals or insects may place foreign objects in the heater.

Keep heater free from foreign objects and combustible materials.

I

S

H

E

N

G

L

Troubleshooting Chart

Symptom

Burner fails to light

Burner lights but goes out when automatic control valve button is released

Burn rate is low, emitter does not glow

Flames are extremely low and coming from emitter

Possible Cause(s)

1. More warm-up time needed

2. Gas pressure is low

3. Thermocouple loose or in need of replacement

4. Automatic control valve in need of replacement

1. Main burner valve not completely open

2. Clogged gas orifice

3. Low gas pressure

4. Low gas supply

1. Main burner valve not fully open

2. Plugged gas orifices

3. Low gas pressure

4. Low fuel supply

Unit has been connected to a natural gas supply instead of propane gas

Corrective Action

1. Relight, holding control valve button in for 45 seconds

2. Inspect propane gas supply

3. Tighten, reconnect or replace thermocouple

4. Replace automatic control valve

1. Completely open main burner valve by turning control knob to HIGH position

2. Replace gas orifice

3. Check gas supply, regulator function

4. Consult gas supplier or replace tank

1. Fully open main burner valve by turning control knob towards HIGH position until it stops

2. Replace gas orifice

3. Check gas supply, regulator output

4. Consult gas supplier or replace tank

Check gas source and replace with propane gas supply

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com

5

PROFESSIONAL GRADE

I I

Dyna-Glo Delux Operating Instructions and Parts Manual

For repair parts, call 1-877-447-4768

Please provide following information:

-Model number

-Serial number (if any)

-Part description and number as shown in parts list

1

2

RA125LPDGD

3

12

10

11

4

5

6

8

9

20

7

19

13

16 21

14

15

17 18

Figure 4 – Repair Parts Illustration for Propane Gas-Fired Radiant Heater

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com

6

Dyna-Glo Delux Operating Instructions and Parts Manual

Model RA125LPDGD

Repair Parts List for Propane Gas-Fired Radiant Heater

Reference

Number Description

9

10

11

12

13

14

15

16

17

18

19

20

21

1

2

3

4

5

6

7

8

Top Cover

Guard

Emitter

Nozzle

Nozzle Connector

Nozzle Nut

Main Gas Tubing Assy (LPG)

Nozzle Bracket

Flame Shield

Thermocouple

Spark Plug

Thermocouple Holder

Base

Control Knob

Control Valve

Fitting

Tubing Inlet Assy (LPG)

Connector Bracket

LPG Inlet Connector

Hose

Regulator

Part Number for Model:

RA125LPDGD

5002854

2315528

2315519

2315522

2315545

2315546

2315640

2315517

2315642

2201584

2201583

2315520

5002851

2101451

5050685

2304948

2315525

2315526

2315527

5002721

5002758

Quantity

1

2

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

I

S

H

E

N

G

L

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com

7 PROFESSIONAL GRADE

I

S

H

E

N

G

L

RA125LPDGD

LIMITED WARRANTY:

This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase. (Shipping costs, labour costs, etc. are the responsibility of the purchaser.)

DUTIES OF THE OWNER:

This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled check or payment record must be kept to verify purchase date and establish warranty period. Original carton should be kept in case of warranty return of unit.

WHAT IS NOT COVERED:

1.

Damage resulting from use of improper fuel.

2.

Damage caused by misuse or use contrary to the owners manual and safety guidelines.

3.

Damage caused by a lack of normal maintenance.

4.

Fuses

5.

Use of non-standard parts or accessories.

6.

Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.

This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM

GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.

THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,

INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE

REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT WILL

GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.

CLAIMS HANDLED AS FOLLOWS:

1. Contact your retailer and explain the problem.

2. If the retailer is unable to resolve the problem, contact ourCustomer Service Dept. detailing the heater model, the problem, and proof of date of purchase.

3. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP,INC. unless instructed by our Representative.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY

AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON-LINE AT www.ghpgroupinc.com

NAME: ______________________________________ PHONE: ( ) __________________ EMAIL: ____________________________

ADDRESS: _________________________________ CITY: ______________________________ STATE: __________ ZIP: ____________

MODEL: ____________________ SERIAL #: _______________________________________ DATE PURCHASED: __________________

DEALER PURCHASED FROM: ____________________________________________ TYPE OF STORE: __________________________

CITY & STATE WHERE PURCHASED: ______________________________________________ PRICE PAID: _______________________

Please Take a Minute To Give Us Your Answers To The Following Questions.

All Responses Are Used Solely For Market Research And Are Held In Strict Confidence.

Who primarily decided this purchase?

Male Female 18-24 25-39 40-59 60 and over

Purpose of Purchase? _______________________________________________________________________________________________

Do you own any other portable heaters? Yes No If yes, type____________________________brand_____________________

How do you intend to use your new heater?

Magazine Ad Friend/Relative How did you become aware of this heater?

TV Commercial Store Salesperson Other ___________________________

What made you select this heater?

Construction Site

In-Store Display

Farm Warehouse/Commercial Garage/Outbuilding Other

Newspaper Ad

Style Size/Portability Price own rent Would you recommend this heater to a friend?

Yes

Package

No

Brand Other ___________________

Do you:

Please give us your comments:________________________________________________________________________________________

THANK YOU FOR COMPLETING THIS FORM!

Information will be held confidential.

WARRANTY REGISTRATION

IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.

GHP Group, Inc.

8280 Austin Ave.

Morton Grove, IL 60053-3207

GHP

Tel: (877) 447-4768 www.ghpgroupinc.com

8280 Austin Avenue

Morton Grove, IL.

6 0 0 5 3 - 3 2 0 7

Tel: ( 847 ) 324 - 5900

Fax: ( 847 ) 324 - 5901

SAVE THIS CARD!

www.ghpgroupinc.com

GHP Group, Inc.

8280 Austin Avenue

Morton Grove, IL 60053-3207

Place

Postage

Stamp

Here

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement