FRC Certificate of Conformance (Bureau Veritas) ()

FRC Certificate of Conformance (Bureau Veritas) ()
BV AVS.4.12.14045/CC-04
Issuing center: Antwerp
Page 1/2
VERITAS
Certificate of Conformity
To ICAO Annex 14 - Fifth Edition - July 2009
(Standards and recommended practices)
To FM Advisory Circular 150/5345-460
To Technical Specification IEC 61827
AENA specification PPT 013-01/07
The undersigned, Rudi Vandenbempt, acting within the scope of the General
Conditions of BUREAU VERITAS, certifies herewith the supply of
Product:
FRC-2-090
Manufactured by ADB bvba in Belgium
Application:
Runway Centreline Inset Light
Was found in conformity with:
• The catalogue sheet A.03.252
• The ICAO - Annex 14 - Volume I - §5.3.12 and Appendix 2 Fig.2-7 for light
output
• The FAA AC 150/5345-46 requirements for L-850A
• The IEC TS 61827
• The AENA Specification PPT 013-01/07
Date and place of inspection: 1ih July 2012
and has been, upon request of:
ADB bvba.
Leuvensesteenweg, 585
B -1930 ZAVENTEM/BELGIUM
- inspected in conformity with the applicable requirements of
• the catalogue sheets A.03.252
• the ICAO - Annex 14 - Volume I
• the FAA AC 150/5345-46 requirements for L-850A
• The AENA Specification PPT 013-01/07 & the IEC TS61827
Issued at Antwerp, July 1ih 2012
Rudi Vandenbempt 1 Inspector
BUREAU VERITAS ANTWERP
Partic· -..n,..<I\iA
This certificate is only valid for a period of 3 years from the issuance date, as far as
no changes of production process, equipment characteristics nor of applicable
requirements occur during this period of validity.
BV AVS.4.12.14045/CC-04
Issuing center: Antwerp
Page 2/2
VERITAS
The following survey operations have been carried out without noticeable remarks:
•
Attendance to tests at the Laboratory premises of the manufacturer:
• Examination of test equipment
• Checking of installation of units before testing
• Attendance to photometric tests according to the applicable procedures and
methods
•
Statistical test results per IEC 61827
•
Test results are detailed in the attached test records, annexed herewith
Review of Intertek ETL Certificate of Conformance dated February 17, 2009
and applicable test reports Intertek
Reports No: Intertek 3164789CRT-001
CONCLUSION
Taking into account the satisfactory results of actual tests and examinations we
confirm that the manufacturing and the test results for the above specified units are in
conformity with applicable standards, specifications and data sheets.
(Details of standards and specifications are indicated on page 1 of this certificate and
data sheet as per catalogue).
ENCLOSURE
Test records of tests which have been attended, duly stamped for identification by
.
BUREAU VERITAS:
Photometric test reports:
• Results of intensity values inside the beam
• Isocandela curves
Issued at Antwerp, July 1ih 2012
Rudi Vandenbempt
Inspector
BUREAU VERITAS ANTWERP
This certificate is only valid for a period of 3 years from the issuance date, as far as
no changes of production process, equipment characteristics nor of applicable
requirements occur during this period of validity.