PT 7186

PT 7186
Installation recommendations
Tumble dryers
PT 7186 G
en - GB
11.09
Mat. No. 07 738 350 / 01
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved
Mat. No. 07 738 350 / 01
2
Technical Datasheet
Tumble dryer:
Heating:
PT 7186
Gas (G)
Legend:
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Optional extras:
UM
BS
Miele plinth
Concrete plinth
UO 6008 (UO = Open plinth)
Height
Width
Depth
mm
mm
mm
305
680
679
UG 6008 (UG = Closed plinth)
Height
Width
Depth
mm
mm
mm
305
692
685
US 6008 (US = Plinth with drawer)
Height
Width
Depth
mm
mm
mm
320
692
685
mm
mm
mm
mm
300
70
≥700
≥700
1. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable cross-sectional area
Connection cable length
Connection cable without plug
(supplied as standard)
V
Hz
kW
A
mm²
mm
1N AC 220 - 230
50
0.40 – 0.46
1 × 10
3 × 1.0
1800
1. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable cross-sectional area
Connection cable length
Connection cable without plug
(supplied as standard)
V
Hz
kW
A
mm²
mm
1N AC 230 - 240
50
0.42 – 0.46
1 × 10
3 × 1.0
1800
Concrete plinth (min. quality C12/15)
Recommended height
Minimum height
Recommended width
Recommended depth
It must be ensured that the concrete plinth is anchored to the
floor!
Machine connections:
Electrical
connection
Country variations:
Technisches Datenblatt / Technical datasheet: PT 7186 G
Datum / Date: 28.10.2009
Seite / Page: 8
Electrical connection must be in accordance with local and
national regulations.
Plug and socket connection in accordance with IEC/EN
60309 and IEC/EN 60947 recommended to facilitate
electrical safety tests.
If the machine is connected via a fixed connection, a multipole switch must be provided on site to ensure complete
isolation. Switches with a contact opening of more than 3 mm
should be used. Such switches are, e.g., LS switches, fuses
and contactors (IEC/EN 60947).
A wall socket or mains isolator must be visible and accessible
after installation.
A new connection, modification of an existing installation or
earth checking, including the determination of suitable fuse
rating, may only be carried out by a suitably qualified
electrician in accordance with all local and national
regulations.
Gas connection
GSS
Machine connection in accordance with ISO 7-1
Inch
The stopcock and connection hose are to be provided on site.
For a direct gas connection, the connection hose, Miele Mat.
no. 4494460, should be used.
½“
The alternative connection via a gas safety socket including
stopcock and connection hose is to be provided on site.
Natural gas
Heater rating
Connection pressure in accordance with DIN EN 437
See operating and installation instructions.
Liquid gas
Heater rating
Connection pressure in accordance with DIN EN 437
See operating and installation instructions.
kW
8.0
kW
7.5
m³/h
Pa
°C
mm
mm
310
440
80
100
100
Note installation instructions for gas-heated Miele tumble
dryers.
Local gas and plumbing regulations must be observed!
Waste air/gas
Nominal air throughput in vented mode
Max. pressure loss
Max. exhaust air/gas temperature
Connection sleeve on machine (inner diameter)
Connection diameter on site (outer diameter)
Connection adapter Miele Mat. no. 6595070 (inner diameter
100 mm) for flexible aluminium duct and adapter piece Miele
Mat. no. 915051 (outer diameter 110 mm) for connection to
normal heat-resistant plastic ducting are supplied as
standard.
As relative humidity in ducting can be as high as 100%,
suitable measures must be taken to prevent a backflow of
condensate into the machine.
Type B22 gas-burning machine.
Waste gas pipework must be pressure-tight.
Note installation instructions for gas-heated Miele tumble
dryers.
Local gas and plumbing regulations must be observed!
Technisches Datenblatt / Technical datasheet: PT 7186 G
Datum / Date: 28.10.2009
Seite / Page: 9
Air intake
Fittings
(supplied)
Machine data
Standard connection:
Air intake from installation site
Recommended air intake vent cross-sectional area
(to prevent draughts in installation site)
Sufficient air intake should be available to replace displaced
volume of air.
cm²
237
Miele plinth UG/UO 6008
4 × fasteners (to secure machine to plinth)
4 × screws DIN 571 (Ø × length)
mm
4 × rawl plugs (Ø × length)
mm
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
8 × 65
12 × 60
Miele plinth US 6008
4 × fasteners (to secure machine to plinth)
4 × screws DIN 571 (Ø × length)
mm
4 × rawl plugs (Ø × length)
mm
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
6 × 50
8 × 40
On concrete plinth
2 × metal brackets
2 × screws DIN 571 (Ø × length)
mm
2 × rawl plugs (Ø × length)
mm
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
6 × 50
8 × 40
Machine width
Machine depth
Machine height
Casing width
Casing depth
mm
mm
mm
mm
mm
700
763
1020
692
690
Min. access width to installation site
Minimum rear wall gap (measured to front of machine)
Minimum wall gap (to front edge of machine)
With an installation with the minimum gap, additional work
may be required when service or repair work is necessary.
mm
mm
mm
720
1300
1100
Net weight
Dynamic floor load, max.
Static floor load, max.
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
kg
N
N
W
78
1000
Not yet available
Not yet available
Sound pressure level (re 20 mPa),
(measured at a distance of 1 m from the machine and at a
height of 1.6 m)
dB (A)
<70
Installation should only be carried out by authorised fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved! Dimensions in mm
Technisches Datenblatt / Technical datasheet: PT 7186 G
Datum / Date: 28.10.2009
Seite / Page: 10