Series M Product Mechanical Metering Pump Selection Effective 01/01/16

Series M Product Mechanical Metering Pump Selection Effective 01/01/16
Mechanical Metering Pump Selection
Series M Product
Effective 01/01/16
2
IMPORTANT INFORMATION
WHEN PLACING AN ORDER
1. Fax, mail or telephone orders directly to the Customer Service Department:
Pulsafeeder Incorporated—A Unit of IDEX Corporation
Standard Product Operations Main Office & Manufacturing Facility
27101 Airport Road, Punta Gorda, Florida, USA 33982-2462 E-Mail: [email protected]
Telephone: 800-333-6677 or 941-575-3800 Fax: 800-456-4085 or 941-575-4085
www.pulsatron.com
2. Please have the following information available when placing an order:
Account Name
Special Tags or Marks (if needed)
Billing Zip Code
Item(s) Being Ordered
Purchase Order Number
Quantity of Each Item
Ship To Address
Pricing
Payment Terms
Shipping Information
3. Orders are entered upon receipt. Our ability to change in house orders is limited. Please be certain your orders are complete when
placed. Any order cancellation or change request is subject to a cancelation fee.
4. Orders are assigned standard lead times based on the size of the order and product mix.
Orders requiring expedited shipping (sooner than the standard lead times) are subject to a expedite charge.
Unless the order clearly requests expedited shipping, the order will be treated as a routine order. When expedited shipping is
requested a designated carrier must be selected. Orders that need to ship the same day must be received by 2:00 PM EST. Same
day and next working day shipping is generally available for larger orders but not guaranteed, please verify with customer service.
Pulsafeeder shall have no liability if it is unable to provide expedited shipping of an order.
5. Repairs and returns are coordinated through our Customer Service Department. All orders returned must have factory authorization
and are subject to a 25% restocking charge for standard product.
6. Other Locations:
PULSAFEEDER-Europe
Via Kennedy, 12-20090
Segrate—Milano– Italy
Tel: +0039 377 706 6300
Latin America (Office Only)
Mario Pani 400, Piso 1, Oficina 111
Col. Lomas de Santa Fe, Cuajimalpa de Morelos
C.P 05300, México, D.F.
Tel: 52-55-4738-4124
•
•
•
•
•
•
•
•
•
•
•
•
Far East (Office Only)
Room 3502-3504, Zhao Feng Plaza
No. 1027 Changning Rd
Shanghai 200050, China
Tel:
86-2163906367
Fax:
86-2163863338
IDEX India Private Ltd.
S14, First Floor
Solitaire Corporate Park,
167, Guru Hargovindji Marg, Chakala
Andheri (East)
Mumbai 400 093, India
Tel: 91-22-66435500
Fax: 91-22-66780055
Prices are subject to change without notice and are effective when order is accepted and acknowledged at point of shipment.
When ordering, specify your P.O. number, model number, quantity, price, shipping and/or billing address and order date.
Standard terms are NET 30 days from date of invoice for approved domestic accounts on open account and NET 60 days from date
of invoice for approved international accounts.
WE ACCEPT VISA AND MASTERCARD.
PAYMENT BY CREDIT CARD WILL NOT RECEIVE AN ADDITIONAL DISCOUNT.
All prices are FCA, Shippers Dock, Punta Gorda, FL.
Custom product sales are final.
Charges for export documentation may apply an very by requirements.
Expedite fees may apply. Orders requiring expedited shipping (sooner than the standard lead times) are subject to an expedite
charge
Fees for changes to or cancellation of orders may apply.
Minimum factory order of $30.
Possession of price schedule does not guarantee right to purchase direct from factory.
We reserve the right to update the information contained in this catalog without notice.
3
Table of Contents
Model Selection Guide4-6
Standard Motor Selections7
Leak Detection / KOPkits8-9
Policies and Procedures10-11
Terms and Conditions12
Application Benefits:
• Reliable Metering Performance
• Simple Installation
• Robust Design
• Environmental Design
• Low Cost of Ownership
Follow the step by step approach presented in this guide to select the features you need.
When you’re through you will have the exact model number for the PULSAtron Series M pump you want.
Applications assistance is available through our Application Engineering Department, Rochester, NY. USA.
Standard Lead Time is three weeks. Consult factory for expedited delivery.
Pulsafeeder, Incorporated
2883 Brighton-Henrietta Townline Road
P.O. Box 22909 (P.O. Zip 14692)
Rochester, New York USA 14623
(585) 292-8000/Fax (585) 424-5619
http://www.pulsa.com
e-mail: [email protected]
4
Model Selection Guide
1, 2, 3, 4
5
6
7
8
9
10
11, 12, 13, 14, 15
Options
Position 10 is a dash
Connection Type Size
Motor Frame Adaptor
Configuration
Control Type
Liquid End Construction
Model
POSITION 1, 2, 3, 4 = Model (pressure & capacity)
L2
L6
Required HP 1/4 or .18 Kw
Required HP 3/4 or .55 Kw
Note: See notes on viscosity and multiplexing
at the end of this section.
PRESSURE AND CAPACITY @ 60 HZ, 1725 RPM
Plastic Construction
Metal Construction
Conn. Size, Inch
Conn. Size, Inch
PSIG
BAR
GPH
LPH
SPM
Suct.
Disch.
Model
PSIG
BAR GPH
LPH
305
21.0
2.7
10.0
58
0.25
0.25
L2F7
305
21.0
10.8
2.8
SPM Suct.
58
0.25
Disch.
Model
0.25
L2C1
305
21.0
3.9
14.9
86
0.25
0.25
L2F8
305
21.0
4.2
16.0
86
0.25
0.25
L2C2
305
21.0
5.3
19.9
115
0.25
0.25
L2F9
305
21.0
5.6
21.3
115
0.25
0.25
L2C3
305
21.0
6.4
24.2
140
0.5
0.5
L2G1
305
21.0
6.9
26.0
140
0.5
0.5
L2C4
305
21.0
7.9
30.0
173
0.5
0.5
L2G2
305
21.0
8.5
32.1
173
0.5
0.5
L2C5
250
17.2
8.1
30.5
58
0.5
0.5
L6R6
250
17.2
8.6
32.7
58
0.5
0.5
L6K7
250
17.2
11.9
45.2
86
0.5
0.5
L6R7
250
17.2
12.8
48.4
86
0.5
0.5
L6K8
250
17.2
16.0
60.5
115
0.5
0.5
L6R8
250
17.2
17.1
64.8
115
0.5
0.5
L6K9
250
17.2
19.4
73.6
140
0.5
0.5
L6R9
250
17.2
20.8
78.9
140
0.5
0.5
L6L1
250
17.2
24.0
91.0
173
0.5
0.5
L6S1
250
17.2
25.7
97.5
173
0.75
0.75
L6L2
160
11.0
6.1
23.2
58
0.5
0.5
L2G3
160
11.0
6.5
24.7
58
0.5
0.5
L2C6
160
11.0
9.2
34.9
58
0.5
0.5
L2G8
160
11.0
9.8
37.0
58
0.5
0.5
L2D2
160
11.0
12.2
46.1
115
0.5
0.5
L2G5
160
11.0
12.9
49.0
115
0.5
0.5
L2C8
160
11.0
13.7
51.7
86
0.5
0.5
L2G9
160
11.0
14.5
54.9
86
0.5
0.5
L2D3
160
11.0
14.8
56.1
140
0.5
0.5
L2G6
160
11.0
15.7
59.6
140
0.5
0.5
L2C9
160
11.0
18.3
69.1
115
0.5
0.5
L2H1
160
11.0
19.4
73.4
115
0.5
0.5
L2D4
160
11.0
22.2
84.1
140
0.5
0.5
L2H2
160
11.0
23.6
89.4
140
0.5
0.5
L2D5
160
11.0
27.5 104.0
173
0.75
0.75
L2H3
160
11.0
29.2
110.0
173
0.75
0.75
L2D6
150
10.3
14.5
54.7
58
0.5
0.5
L6S2
150
10.3
15.4
58.2
58
0.5
0.5
L6L3
150
10.3
21.4
81.2
86
0.5
0.5
L6S3
150
10.3
22.8
86.2
86
0.5
0.5
L6L4
150
10.3
24.1
91.2
58
0.5
0.5
L6S7
150
10.3
25.6
96.9
58
0.75
0.75
L6L8
150
10.3
28.7 109.0
115
0.75
0.75
L6S4
150
10.3
30.5
115.0
115
0.75
0.75
L6L5
150
10.3
35.7 135.0
86
0.75
0.75
L6S8
150
10.3
38.0
144.0
86
0.75
0.75
L6L9
150
10.3
43.1 163.0
173
0.75
0.75
L6S6
150
10.3
45.8
173.0
173
0.75
0.75
L6L7
150
10.3
47.8 181.0
115
0.75
0.75
L6S9
150
10.3
50.8
192.0
115
0.75
0.75
L6M1
150
10.3
58.2 220.0
140
1.0
1.0
L6T1
150
10.3
61.8
234.0
140
1.0
1.0
L6M2
150
10.3
71.9 272.0
173
1.0
1.0
L6T2
150
10.3
76.4
289.0
173
1.0
1.0
L6M3
5
PRESSURE AND CAPACITY @ 60 HZ, 1725 RPM
Plastic Construction
Metal Construction
Conn. Size, Inch
Conn. Size, Inch
PSIG
BAR
GPH LPH SPM
Suct.
Disch.
Model
PSIG
75
5.2
53.1
0.75
0.75
L6T3
75
201
58
BAR GPH
5.2
55.3
LPH
210
SPM Suct.
58
0.8
Disch.
Model
0.8
L6M4
75
5.2
78.7
298
86
1.0
1.0
L6T4
75
5.2
82.1
311
86
1.0
1.0
L6M5
75
5.2
105
398
115
1.5
1.0
L6T5
75
5.2
109
416
115
1.5
1.0
L6M6
75
5.2
128
485
140
1.5
1.0
L6T6
75
5.2
134
506
140
1.5
1.0
L6M7
75
5.2
158
599
173
1.5
1.0
L6T7
75
5.2
165
625
173
1.5
1.0
L6M8
PRESSURE AND CAPACITY @ 50 HZ, 1425 RPM
Plastic Construction
Metal Construction
Conn. Size, Inch
PSIG
BAR
GPH LPH SPM
305
21.0
2.2
8.3
305
21.0
3.2
12.3
305
21.0
4.3
305
21.0
5.2
305
21.0
305
21.0
250
250
Conn. Size, Inch
Suct.
Disch.
Model
PSIG
BAR GPH
LPH
SPM Suct.
Disch.
Model
48
0.25
0.25
L2D7
305
21.0
2.4
8.9
48
71
0.25
0.25
L2D8
305
21.0
3.5
13.2
71
0.25
0.25
L2A1
0.25
0.25
L2A2
16.5
95
0.25
0.25
L2D9
305
21.0
4.7
17.6
19.7
114
0.25
0.25
L2E1
305
21.0
5.6
21.2
95
0.25
0.25
L2A3
114
0.25
0.25
L2A4
6.5
24.8
143
0.5
0.5
L2E2
305
21.0
7.0
26.5
8.1
30.8
178
0.5
0.5
L2E3
305
21.0
8.7
33
143
0.5
0.5
L2A5
178
0.5
0.5
L2A6
17.2
6.7
25.2
48
0.5
0.5
L6M9
250
17.2
7.1
17.2
9.9
37.3
71
0.5
0.5
L6N1
250
17.2
10.6
27
48
0.5
0.5
L6W1
40
71
0.5
0.5
L6W2
250
17.2
13.2
50
95
0.5
0.5
L6N2
250
17.2
14.1
54
95
0.5
0.5
L6W3
250
17.2
15.8
59.9
114
0.5
0.5
L6N3
250
250
17.2
19.9
75.2
143
0.5
0.5
L6N4
250
17.2
17.0
64.2
114
0.5
0.5
L6W4
17.2
21.3
80.6
143
0.5
0.5
L6W5
250
17.2
24.7
93.6
178
0.75
0.75
L6N5
160
11.0
5.1
19.2
48
0.5
0.5
L2E4
250
17.2
26.5
100
178
0.75
0.75
L6W6
160
11.0
5.4
20.4
48
0.5
0.5
L2A7
160
11.0
7.6
28.8
48
0.5
0.5
L2F1
160
11.0
8.1
30.6
48
0.5
0.5
L2B4
160
11.0
10.1
38.1
95
0.5
0.5
L2E6
160
11.0
10.7
40.4
95
0.5
0.5
L2A9
160
11.0
11.3
42.7
71
0.5
0.5
L2F2
160
11.0
12.0
45.3
71
0.5
0.5
L2B5
160
11.0
12.1
45.7
114
0.5
0.5
L2E7
160
11.0
12.8
48.5
114
0.5
0.5
L2B1
160
11.0
15.1
57.1
95
0.5
0.5
L2F3
160
11.0
16.0
60.7
95
0.5
0.5
L2B6
160
11.0
18.1
68.5
114
0.5
0.5
L2F4
160
11.0
19.2
72.8
114
0.5
0.5
L2B7
160
11.0
18.8
71.3
178
0.5
0.5
L2E9
160
11.0
20.0
75.8
178
0.5
0.5
L2B3
160
11.0
22.7
85.9
143
0.5
0.5
L2F5
160
11.0
24.1
91.3
143
0.75
0.75
L2B8
160
11.0
28.3
107
178
0.75
0.75
L2F6
160
11.0
30.0
114
178
0.75
0.75
L2B9
150
10.3
12.0
45.3
48
0.5
0.5
L6N6
150
10.3
12.7
48.1
48
0.5
0.5
L6W7
150
10.3
17.7
67
71
0.5
0.5
L6N7
150
10.3
18.8
71
71
0.5
0.5
L6W8
150
10.3
19.9
75.5
48
0.5
0.5
L6P3
150
10.3
21.2
80.2
48
0.5
0.5
L6J4
150
10.3
23.7
89.7
95
0.5
0.5
L6N8
150
10.3
25.2
95.3
95
0.75
0.75
L6W9
150
10.3
28.4
108
114
0.75
0.75
L6N9
150
10.3
30.2
114
114
0.75
0.75
L6J1
150
10.3
29.5
112
71
0.75
0.75
L6P4
150
10.3
31.3
119
71
0.75
0.75
L6J5
150
10.3
35.7
135
143
0.75
0.75
L6P1
150
10.3
37.9
143
143
0.75
0.75
L6J2
150
10.3
39.5
149
95
0.75
0.75
L6P5
150
10.3
41.9
159
95
0.75
0.75
L6J6
150
10.3
44.4
168
178
0.75
0.75
L6P2
150
10.3
47.2
178
178
0.75
0.75
L6J3
150
10.3
47.4
179
114
0.75
0.75
L6P6
150
10.3
50.3
191
114
0.75
0.75
L6J7
150
10.3
59.4
225
143
1.0
1.0
L6P7
150
10.3
63.1
239
143
1.0
1.0
L6J8
150
10.3
74.0
280
178
1.0
1.0
L6P8
150
10.3
78.6
298
178
1.0
1.0
L6J9
6
PRESSURE AND CAPACITY @ 50 HZ, 1425 RPM
Plastic Construction
Metal Construction
Conn. Size, Inch
PSIG
BAR
75
Conn. Size, Inch
GPH LPH SPM
Suct.
Disch.
Model
PSIG
BAR
GPH LPH SPM
Suct.
Disch.
Model
5.2
43.9
166
48
0.75
0.75
L6P9
75
5.2
45.8
173
48
0.75
0.75
L6K1
75
5.2
65.0
246
71
1.0
1.0
L6R1
75
5.2
87.0
329
95
1.0
1.0
L6R2
75
5.2
67.8
256
71
1.0
1.0
L6K2
75
5.2
90.7
344
95
1.0
1.0
L6K3
75
5.2
104
395
114
1.5
1.0
75
5.2
131
496
143
1.5
1.0
L6R3
75
5.2
108
412
114
1.5
1.0
L6K4
L6R4
75
5.2
137
517
143
1.5
1.0
L6K5
75
5.2
163
617
178
1.5
1.0
L6R5
75
5.2
170
643
178
1.5
1.0
L6K6
1. VISCOSITIES: For viscosities up to 3000 cp. select the pump stroking rates as follows:
0-50 CP = 178 SPM Max.
51-500 CP = 115 SPM max.
501-1500 CP = 95 SPM Max.
1501-3000 CP = 71 SPM Max.
2. MULTIPLEXING: For duplexing, select the same stroking rate (SPM) for both pumps. The power requirement for a duplex is one
motor size larger than the normal motor size required largest pump of the two. If both pumps discharge to a common line, the rated
discharge pressure will be the lowest of the pump pair. For multiplexing configurations of three or more pumps, consult factory.
POSITION 5 = Liquid End Construction
Liquid End
Construction
CHECK VALVES
Liquid End Construction with Leak Detection Diaphragm, List Price Adders
Code
Reagent
Head
Diaphragm
A
316 SS
TFE Faced 316 SS 316 SS
PTFE
316 SS
0-158° -18-70°C
H
Q
B
16 SS (1)
TFE Faced
PTFE
316 SS
0-158° -18-70°C
J
R
Ball
HCO
Seat
020 SS
Temp. Range
⁰F, ⁰C
Gasket Valve Cap
With Gauge Only (3)
<53 gph (201 lph)/>53 gph (201 lph)
E
PVC
TFE Faced
ALA
PVC
PTFE
PVC
0-104° -18-40°C
M
U
G
PVC (2)
TFE Faced
HCO
PVC
PTFE
PVC
0-104° -18-40°C
P
W
F
PVDF
TFE Faced HCO PVDF PTFE
PVDF
0-158° -18-70°C
N
NOTES: (1) Recommended for applications handling commercial concentrated sulfuric acid (66⁰ BE / 93+%).
(2) Recommended for applications handling sodium hypochlorite.
POSITION 6 = Control Type
STROKE LENGTH CONTROL
M -
Manual
POSITION 7 = Configuration
S
-
Simplex (Standard-gearbox on left)
D
-
Duplex (Driver)
E
-
Duplex (Driven)*
L
With Gauge & Switch (4)
<53 gph (201 lph)/>53 gph (201 lph)
-
Simplex (Gearbox on right)
*When “E” is selected in position 7, place an “X” in position 8.
Also, select the driven pump to have the same SPM
(Strokes per Minute) as the driver pump.
V
(3) Pressure gauge: 316 SS, 0-300 psig, 0-21 bar range.
(4) Switch: NEMA 7, IP66, EExd plus same gauge as above. POSITION 9 = Connection Type (1)
P
- Threaded Female (NPT)
B
- Threaded Female (BSPT)
F
- Flanged (ANSI) (2)
G
- Flanged (DIN) (2)
Connection Type Notes:
List Price Adder to NPT
Flanged Connections Suct. Flanged, ANSI or DIN
x Disch.
PVC
PVDF
0.5” x 0.5”
(1) PVC & PVDF threaded connections 0.75” x 0.75”
use cartridge valves.
1.0” x 1.0”
All other selections use 3-component
1.5” x 1.0”
valves with tie bars.
(2) Standard 0.25” x 0.25” threaded connections are increased to 0.5” x 0.5” for the flanged
connections option, use the price adder for 0.5” x 0.5” for flanged connections.
(3) CF = Consult Factory
POSITION 8 = Motor Frame Adapter POSITION 10 = Is a dash “-”
A -
56C
D
-
143 TC OR 145 TC
B
-
71 (Metric)
C
-
80 (Metric)
X
-
No Gearbox/Motor Adaptor
316
POSITION 11-15 = Options
XXXXX
Options codes assigned by factory
CF
7
Standard Motor Selections
RECOMMENDED POWER AND SPEED
Model L2 - 1/4 HP, .18 Kw; 1725 RPM, 1425 RPM
Model L6 - 3/4 HP, .55 Kw; 1725 RPM, 1425 RPM
Pump
Model
Power
Part No.
Motor Voltage
Phase
Hz
AC/DC
RPM
Frame
Enclosure
L2
1/4 HP
NP500033-000
115/208/230
1
60
AC
1725
56C
TEFC
L2
1/4 HP
NP500034-000
208/230/460
3
60
AC
1725
56C
TEFC
L2
1/4 HP
NP500035-000
115/208/460
1
60
AC
1725
56C
XP (3)
L2
1/4 HP
NP500036-000
208/230/460
3
60
AC
1725
56C
XP (3)
L2
1/2 HP
NP500197-000 230/460 or 190/380
3
60 or 50
AC
1725 or 1425
56C
Inv Ready (2)
L2
1/3 HP
NP500045-000
110/220
1
50
AC
1425
56C
TEFC/IP54
L2
1/4 HP
NP500044-000
220/380/440
3
50
AC
1425
56C
TEFC/IP54
L6
3/4 HP
NP500003-000
115/208/230
1
60
AC
1725
56C
TEFC
L6
3/4 HP
NP500007-000
208/230/460
3
60
AC
1725
56C
TEFC
L6
3/4 HP
NP500011-000
115/208/230
1
60
AC
1725
56C
XP (3)
L6
3/4 HP
NP500015-000
208/230/460
3
60
AC
1725
56C
XP (3)
L6
3/4 HP
NP500021-000
115/208/230
1
60
AC
1725
56C
Wash Down
L6
1 HP
NP500199-000 230/460 or 190/380
3
60 or 50
AC
1725 or 1425
56C
Inv Ready (2)
L6
3/4 HP
NP500047-000
3
50
AC
1425
56C
TEFC/IP54
L6
.55 kW
NP500057-000 220-240 or 380-415
3
50
AC
1425
80M
IP55
220/380/440
NOTES: (1) No power cord supplied, Direct wiring required.
(2) Inverter Ready motors provide a 4:1 speed turndown with a separate AC inverter
(3) XP Motors are suitable for Class 1 Division 1 Group D only.
8
LEAK DETECTION: This illustration indicates the arrangement of the leak detection offering.
Notice that the pressure switch is located behind the reagent head and does NOT thread into the reagent head.
KOPkits KEEP ON PUMPING Kits Save You Money and Time
Pulsafeeder has built a reputation for superior reliability by supplying carefully designed, high quality equipment. Even the best equipment, however, requires a minimal amount of maintenance. KOPkits are designed to guard against unnecessary down-time and
assure you of the highest level of efficient service from your PULSAR Series M pumps. KOPkits contain all the parts which experience
has shown require periodic replacement to assure reliable operation.
The PULSAtron Series M KOPkit Item Number:
The KOPkit number for Series M pumps is an 8 digit number. This number is found on the pump nameplate. A KOPkit number can be
created as follows: the first 3 digits are always NLK. The next 3 digits correspond to the model and size (see tables that follow) the
seventh digit is the liquid end construction code, which is position 5 of the pump model number. The eight digit is the connection type,
which is position 9 of the pump model number.
9
KOPkit List Price
Liquid End Construction Selection
KOPkit # Less Material
B, J,R 316
Code and Conn. Type A, H, Q 316
(1)
E, M, U
PVC
G, P, W
PVC(2)
F, N, V
PVDF
NLK001
NLK002
NOTES:
See previous page for instructions.
For pumps with leak detection, order the same kits listed here. The
secondary (rear) diaphragm may be ordered separately.
NLK003
NLK004
NLK005
(1) Recommended for applications handling commercial concentrated sulfuric acid (66° Be/ 93+%).
NLK006
(2) Recommended for applications handling sodium hypochlorite.
NLK007
NLK008
Example:
NLK009
Pump: M2F7FMSAP-XXXXX
NLK010
KOPkit: NLK001FP
Pump
Model
KOPkit # Less Material
Code and Conn. Type
Pump
Model
KOPkit # Less Material
Code and Conn. Type
Pump
Model
KOPkit # Less Material
Code and Conn. Type
Pump
Model
KOPkit # Less Material
Code and Conn. Type
L2A1
NLK001
L2E6
NLK003
L6K6
NLK010
L6P7
NLK007
L2A2
NLK001
L2E7
NLK003
L6K7
NLK003
L6P8
NLK007
L2A3
NLK001
L2E9
NLK003
L6K8
NLK003
L6P9
NLK008
L2A4
NLK001
L2F1
NLK003
L6K9
NLK003
L6R1
NLK009
L2A5
NLK002
L2F2
NLK003
L6L1
NLK003
L6R2
NLK009
L2A6
NLK002
L2F3
NLK003
L6L2
NLK004
L6R3
NLK010
L2A7
NLK003
L2F4
NLK003
L6L3
NLK005
L6R4
NLK010
L2A9
NLK003
L2F5
NLK003
L6L4
NLK005
L6R5
NLK010
L2B1
NLK003
L2F6
NLK004
L6L5
NLK006
L6R6
NLK003
L2B3
NLK003
L2F7
NLK001
L6L7
NLK006
L6R7
NLK003
L2B4
NLK003
L2F8
NLK001
L6L8
NLK006
L6R8
NLK003
L2B5
NLK003
L2F9
NLK001
L6L9
NLK006
L6R9
NLK003
L2B6
NLK003
L2G1
NLK002
L6M1
NLK006
L6S1
NLK003
L2B7
NLK003
L2G2
NLK002
L6M2
NLK007
L6S2
NLK005
L2B8
NLK004
L2G3
NLK003
L6M3
NLK007
L6S3
NLK005
L2B9
NLK004
L2G5
NLK003
L6M4
NLK008
L6S4
NLK006
L2C1
NLK001
L2G6
NLK003
L6M5
NLK009
L6S6
NLK006
L2C2
NLK001
L2G8
NLK003
L6M6
NLK010
L6S7
NLK005
L2C3
NLK001
L2G9
NLK003
L6M7
NLK010
L6S8
NLK006
L2C4
NLK002
L2H1
NLK003
L6M8
NLK010
L6S9
NLK006
L2C5
NLK002
L2H2
NLK003
L6M9
NLK003
L6T1
NLK007
L2C6
NLK003
L2H3
NLK004
L6N1
NLK003
L6T2
NLK007
L2C8
NLK003
L6J1
NLK006
L6N2
NLK003
L6T3
NLK008
L2C9
NLK003
L6J2
NLK006
L6N3
NLK003
L6T4
NLK009
L2D2
NLK003
L6J3
NLK006
L6N4
NLK003
L6T5
NLK010
L2D3
NLK003
L6J4
NLK005
L6N5
NLK004
L6T6
NLK010
L2D4
NLK003
L6J5
NLK006
L6N6
NLK005
L6T7
NLK010
L2D5
NLK003
L6J6
NLK006
L6N7
NLK005
L6W1
NLK003
L2D6
NLK004
L6J7
NLK006
L6N8
NLK006
L6W2
NLK003
L2D7
NLK001
L6J8
NLK007
L6N9
NLK006
L6W3
NLK003
L2D8
NLK001
L6J9
NLK007
L6P1
NLK006
L6W4
NLK003
L2D9
NLK001
L6K1
NLK008
L6P2
NLK006
L6W5
NLK003
L2E1
NLK001
L6K2
NLK009
L6P3
NLK005
L6W6
NLK004
L2E2
NLK002
L6K3
NLK009
L6P4
NLK006
L6W7
NLK005
L2E3
NLK002
L6K4
NLK010
L6P5
NLK006
L6W8
NLK005
L2E4
NLK003
L6K5
NLK010
L6P6
NLK006
L6W9
NLK006
10
Policies and Procedures
1.
Manufacturer’s Equipment Warranty
a.
Pulsafeeder warrants all pumps and controllers of its manufacture to be free of defects in material or workmanship.
Liability under this policy extends for 24 months from the date of shipment. The manufacturer’s liability is limited to repair
or replacement of any failed equipment or part which is proven defective in material or workmanship upon manufacturer’s
examination. This warranty does not include removal or installation costs and in no event shall the manufacturer’s liability
exceed the selling price of such equipment or part.
b.
The manufacturer disclaims all liability for damage to its products through improper installation, maintenance, use or attempts
to operate such products beyond their functional capacity, intentionally or otherwise, or any other unauthorized repair. The
manufacturer is not responsible for consequential or other damages, injuries or expense incurred through the use of its
products.
c.
The above warranty is in lieu of any other warranty, whether expressed or implied. The manufacturer makes no warranty of
fitness or merchantability. No agent of ours is authorized to provide any warranty other than the above.
Pulsafeeder’s Parts and Accessory Warranty
a.
Pulsafeeder, Inc. warrants parts and accessories provided to be free of defects in material or workmanship. Unless otherwise
noted below, liability under this policy extends for 90 days from date of shipment from the factory when sold as service parts.
(Replaceable elastomeric parts (PTFE) are expendable and are not covered by any warranty either expressed or implied.)
b.
This policy is extended to a full 12 months from the date of installation or 18 months from shipment from the factory whichever
comes first on the following accessories;
Digital Glycol Feeders
Pre-Engineered Systems
Corrosion Coupon Racks
Analog Timers
Water Meters
Flow Controllers
c.
MicroTrac and MicroVision toroidal probes are warranted for 24 months from date of shipment from the factory when
purchased in conjunction with the controller.
All other electrodes/probes and sensors are considered maintenance items and such are warranted for six (6) months from
the date of shipment when purchased in conjunction with the controller.
Any electrodes/probes other than toroidal and sensors purchased as spare parts are warranted for 90 days from date of
shipment.
d.
The manufacturer’s liability is limited to repair or replacement of any failed equipment or part which is proven defective in
material or workmanship upon manufacturer’s examination. This warranty does not include removal or installation costs and
in no event shall the manufacturer’s liability exceed the selling price of such equipment or part.
e.
The manufacturer disclaims all liability for damages to its products through improper installation, maintenance, use or
attempts to operate such products beyond their functional capacity, intentionally or otherwise, or any unauthorized repair.
The manufacturer is not responsible for consequential or other damages, injuries or expense incurred through the use of its
products.
f.
The above warranty is in lieu of any other warranty, whether expressed or implied. The manufacturer makes no warranty of
fitness or merchantability. No agent of ours is authorized to provide any warranty other than the above.
Process for All Returned Goods (Warranty Items)
a.
Please contact our Technical Service Department to request a RMA (Return Material Authorization) number prior to returning
any goods. The following information will be required:
Billing and ship-to address
Model number and serial number
Contact name and phone number
Reason for return
Purchase order (where applicable)
A packing slip will be provided to the shipper and MUST accompany the product being returned. Packages received without
our proper packing list will be refused by the receiver.
b.
All material must be returned freight prepaid.
c.
All material must be properly packaged to prevent damage in shipment.
d. All products used in a chemical application MUST accompany an MSDS
e.
All products MUST be wiped and flushed clean of any and all chemicals, solvents or buffers and be warranted to be safe for
handling. You will be requested to acknowledge the condition of the product being returned on our packing list. Any product
received that is deemed to be unsafe for handling or without this acknowledgement will be refused by our receiver.
f.
All warranty repairs will follow the 2 year warranty policy and will refer to the original purchase date.
Non-Warranty Return Procedure (Charge Repair)
a.
If you are experiencing a concern with your Pulsafeeder product, first consult the distributor, dealer or Regional Sales
Manager or the operation and maintenance manual for assistance. If service of your non-warranty unit is necessary, you
must request a return material authorization. A RMA form will be issued and must be used as the packing list attached to the
outside of the box. Please send the unit freight prepaid with the RMA number visibly displayed on the outside of the carton.
All products MUST be wiped and flushed clean of any and all chemicals, solvents or buffers and be warranted to be safe for
handling. You will be requested to acknowledge the condition of the product being returned on our packing list. Any product
received that is deemed to be unsafe for handling or without this acknowledgement will be refused by our receiver.
b.
All products used in a chemical application MUST accompany an MSDS
c..
The charges listed in the following table will apply.
2.
3.
4.
Product
Repair Cost
Pumps and Pump Accessories – within 5 years of sale date
Current List Price x .50 x Part Discount Multiplier
Controllers and Controller Accessories within 5 years of sale date
Current List Price x .50 x Part Discount Multiplier
Any item older than 5 years from date of sale
With purchase order, $50 bench fee to evaluate. The $50 bench fee may be applied towards repair cost of
unit or towards a new controller
All Charge Repairs have a 90 day warranty from date of repair
Policies and Procedures continued
11
5.
Credit for Return of New, Unused Equipment
a.
No equipment will be accepted beyond six months after date of shipment from factory for credit.
b.
Only new, unused and undamaged standard equipment will be accepted for return to stock.
c.
All credits are based on evaluation and acceptance of material as new and unused by Pulsafeeder. You will be requested to
acknowledge the condition of the product being returned on our packing list. Any product received that is deemed to be unsafe for
handling or without this acknowledgement will be refused by our receiver.
d.
A restocking fee of 25% will apply to returned goods. When a PO is provided for a replacement item at the time of the return
request the restocking fee will be 15%. Note: any product mounted on a panel or skid will be charged a 50% re-stocking fee.
e.
A request for a Returned Material Authorization (RMA) number must be made prior to returning product to Pulsafeeder.
f.
All equipment shall be returned with the RMA Packing List form attached to the outside of the box.
g.
If any chemical, solvent or buffer has been introduced into the product it must be wiped and flushed clean of any and all
substances prior to returning to Pulsafeeder.
h.
All material shall be returned freight prepaid.
i.
Private label products or Engineered Panel Mount Systems are not returnable.
6.
Pricing Errors
a.
Pulsafeeder does their very best to avoid errors in billing. You will receive a confirmation of your order within 24 hours of order
entry. If upon review the customer feels there is a discrepancy, they should contact Pulsafeeder Customer Service as soon as
possible to resolve.
b.
Should an invoice be received that the customer believes to have incorrect pricing, they should notify Pulsafeeder Customer
Service to investigate.
Missing Items
a.
If a product is received by the customer with an item missing the customer must notify Pulsafeeder Customer Service within 7 days
of receipt of the product by the end user. A replacement item will be sent at no charge as quickly as possible.
b.
If a shipment is received by the customer with a line item missing they must notify Pulsafeeder Customer Service within 7 days
of receipt of the product by the end user. If the customer had been billed for that item, a credit will be issued against the original
Sales Order and a new Sales Order will be created for the replacement product.
Damaged Items
a.
Should the customer receive an order that was damaged in transit, the customer must notify the carrier directly to initiate a claim
on the day of delivery.
b.
Should the customer receive a product with damaged components due to improper packaging they should notify Pulsafeeder
Customer Service within 7 days of receipt of product by end user. A replacement item will be sent at no charge as quickly as
possible.
Technical Support Services Available
a.
Pulsafeeder’sSales Support teamavailableall yourand support. The principle mission of this group is to sell and support our
customer base in a timely and effective manner. This includes the ability to provide in-field service training, assistance in start-up
of our products and perform field repair of goods when required.
b.
Scope
Pulsafeeder, Inc. factory Field Service Technicians are available throughout the World for field services on all Pulsafeeder
products. Services include:
i.
Maintenance Training Seminars, including Classroom slide presentations and or Hands-on Training. The seminar
will take approximately four to five hours, and if time permits minor repair and or adjustments may be made to the
customer’s pumps, controllers or accessories.
ii.
Pre-start up inspections and start up testing/calibration of pumps, controllers and accessories.
iii.
Field repairs of pumps controllers and accessories
iv.
Diagnosing and recommending solutions to systems problems.
7.
8.
9.
Fee Schedule
Field Repairs and Start-Ups
Service Rate (1)
Normal 8 hour day
$125.00 / hour
Overtime (in excess of 8 hrs each day)
$175.00 / hour
Sundays, National Holiday
$225.00 / hour
Travel time to job site and return
$115.00 / hour
Travel expenses (air fare, hotel, car and meals)
Chargeable to customer at cost.
Minimum charge
4 hour labor, plus travel time and expenses
End User Training Seminars
(1)
Normal work day
$1000.00 / day plus expenses (air fare, car rental, hotel and meals at cost)
Sundays, National Holiday
$1800.00 / day plus expenses (air fare, car rental, hotel and meals at cost)
All rates listed in this section are actual hourly and daily rates, not reference rates
12
TERMS & CONDITIONS
1 . AGREEMENT. The contract of sale resulting from Seller’s documentation together with these terms and conditions (“Contract”) constitutes the
entire agreement between the parties hereto, except as modified in writing signed by both the Seller and Purchaser. The Seller is Pulsafeeder, Inc. and
the Purchaser is identified in the Contract. Any terms in a purchase order, irrespective of their materiality, which are either different from or additional
to Seller’s conditions of sale, are objected to and are excluded unless the Seller expressly agrees in writing to such terms. Execution of such forms
by Seller to accommodate Purchaser’s procurement or accounting procedures or to evidence agreed up on change orders shall not be construed as
assent to Purchaser’s terms. Acceptance of the goods shipped shall constitute assent to Seller’s conditions of sale. This Contract shall be binding up
on Purchaser and Seller, and on their successors and assigns.
2 . PROPOSAL OR QUOTATION. A proposal shall not become binding up on Seller until it has been executed and returned by Purchaser. An oral
quotation shall not be considered an offer: only a written confirmation thereof incorporating Seller’s terms and conditions shall constitute an offer. All
quotations are valid for 30 days unless stated different on the written quotation.
3. ORDER PLACEMENT. All orders shall be subject to acknowledgement by Pulsafeeders and shall be subject to Pulsafeeder’s terms and conditions
in effect on the date the order is accepted. No modifications to the terms and conditions referred to or contained in any request for proposal, order, or
other document from a customer shall apply unless negotiated and approved via written documentation with Pulsafeeder SPO. Any order cancellation
or change request is subject to a cancelation / change fee.
The minimum order amount is US$30.00 based on Pulsafeeders list prices in effect at the time the order is received.
All orders must be submitted with correct pricing and shipping information. Orders submitted without correct pricing and shipping information may be
rejected or delayed.
4 . CREDIT. Credit terms of payment must have the approval of Seller’s Credit Department and must be specified in writing on Seller’s invoice or in
the Contract. If Purchaser’s credit is found by Seller to be unsatisfactory . Seller may rescind or terminate this contract. If at any time during the term of
this contract purchaser’s financial responsibility becomes impaired or unsatisfactory to Seller, Seller reserves the right to stop shipment on notification
to Purchaser, project owner and surety with a demand for payment in advance or at time of delivery for future deliveries or to require other security
satisfactory to Seller and in the absence thereof, to cancel the unfilled portion of the Contract. Seller will notify Purchaser promptly of its decision to
stop shipments and give an advance notice to the extent this is possible. In the absence of credit terms, sales are for cash.
5. PAYMENT. Specific terms of payment for this order shall be set forth on the reverse side of this Contract or identified and appended hereto.
Purchaser agrees to make payment at Seller’s location specified in this Contract in lawful money of the United States. Purchaser further agrees to
make all payments when due to Seller in accordance with the agreed terms of payment in this Contract without reference to Purchaser’s agreement
with or payments by the owner and with no right of retention.
6 . INTEREST AND COSTS. Purchaser agrees to pay interest at 1.5% per month (to the extent permitted by law) on all delinquent balances if and
when assessed by Seller, and any attorney’s fees or court costs arising out of and made necessary in collection of its obligation to Seller created by
this Contract.
7 . TAXES. Any federal, state or local tax assessment, fee, duty or charge hereafter imposed on or measured by the products purchased hereunder
shall be for Purchaser’s account unless Purchaser furnishes Seller an acceptable exemption certificate from such tax, fee, duty or charge prior to
shipment.
8 . FORCE MAJEURE. Seller shall make delivery in accordance with the terms of this Contract or within a reasonable time in the absence of any
commitment, but Seller shall not be liable for delays or defaults in delivery caused by floods, fires, storms, or other acts of God, by war or act of public
enemy (or civil disturbance), strikes, lock outs, shortages of labor or raw materials and supplies (including fuel) or production facilities, transportation
service or equipment shortages or failures, action of any governmental authority or other conditions beyond Seller’s reasonable control.
9 . CANCELLATION. If Purchaser desires to cancel or change any portion of this Contract, the purchaser must make such request in writing to Seller.
Seller may, in its sole discretion, accept or reject any such request. If accepted, the Purchaser nonetheless must take delivery and make payment to
Seller for all material manufactured and in process of manufacture at time of notice, and all special materials ordered at time of notice and for which
Seller must take delivery , unless otherwise agreed by Seller in writing. All such materials must be removed from Seller’s premises within 30 days
after payment and payment will due at time of notice. Seller also reserves the right to make a cancellation charge in the event of cancellation by the
Purchaser of an order placed in Seller’s shipping schedule and acknowledged by Seller. Any order cancellation is subject to a cancelation fee.
10 . INSPECTION AND TESTING . Seller’s standard specifications and tests apply to all orders. All charges for inspections or tests not regularly
furnished are for Purchaser’s account and subject to prior negotiation. All inspections shall be conducted at Seller’s plant, and failure of Purchaser to
avail himself of inspection privileges shall be deemed a waiver of such privileges.
11 . PRICES. Prices are subject to change without notice. Orders based on published prices and accepted for scheduled shipment will be invoiced at
Seller’s applicable price in effect on the scheduled date of shipment, unless otherwise specifically noted on the order acknowledgment. All prices will be
in accordance with applicable government regulations. Orders specifying palletizing or special packaging will involve special charges.
12 . DELAYS. All orders are accepted subject to Seller’s ability to make delivery at the time and in the quantities specified, and Seller shall not be liable
for damages for failure to make partial or complete shipment or for any delay in making shipments. Purchaser shall be liable for any added expenses
incurred by Seller because of Purchaser’s delay in furnishing requested information to Seller, delay resulting from order changes by Purchaser, or
delay in unloading shipments at delivery point.
13 . SHIPMENT. Seller will select method of shipment and routing when transportation charges are for account of Seller. When shipping instructions
are specified by the Purchaser, all costs will be for the account of the Purchaser. The foregoing includes, but is not limited to, carriers charges for
notification prior to delivery, demurrage, delay in unloading, diversion, or reconsignment. All shipments are Free Carrier (FCA) or EX Works( EXW)
(Incoterms 2010) shippers dock Punta Gorda FL.
On all customer arranged freight (will advise) the customer has 48 hours after Pulsafeeder has advised them that the shipment is complete and ready
for shipment to arrange pickup. If the shipment has not left Pulsafeeder within the 48 hour period the customer will be charged 1% of the shipment
invoice value for each 24 hour period that the shipment remains at the Pulsafeeder facility. Pulsafeeder may also place the shipment in a public storage
at the customer’s expense and without liability to Pulsafeeder.
Any expedited order will be subject to a expedite fee.
13
Unless the order clearly requests expedited shipping, the order will be treated as a routine order. When expedited shipping is requested a designated
carrier must be selected. Orders that need to ship the same day must be received by 2:00 PM EST. Same day and next working day shipping is
generally available for larger orders but not guaranteed, please verify with customer service. Pulsafeeder shall have no liability if it is unable to provide
expedited shipping of an order.
14 . TITLE. Title to products transfers up on shipment from the Pulsafeeder facility according to FCA Shippers Dock or EXW Punta Gorda FL
(Incoterms 2010). Purchaser is then responsible for proper protection of product, placement, compliance with all regulations and ordinances, and will
indemnify Seller against all claims for personal injuries or property damage arising from the storage, use or handling of such products.
15 . IN TRANSIT CLAIMS. Claims for damage or shortage in transit must be made against the carrier by the owner of the shipment according to the
FCA or EXW terms of the Contract. Purchaser has the responsibility to inspect shipments before or during unloading to identify any such damage or
shortage and see that appropriate notation is made on the delivery tickets or an inspection report furnished by the local agent of the carrier in order to
support a claim.
16 . CLAIMS. Notice of Claims against Seller hereunder for any reason, must be made to Seller in writing promptly after discovery and within any
applicable warranty period. Failure to give such notice to Seller shall constitute a waiver by Purchaser of any right later to assert such a claim.
17 . RETURNS. Returned goods shall be accepted for credit only if in salable condition and only with evidence of Seller’s prior written consent. Seller
will assess charges for freight both ways and any costs necessary to restore such goods to the regular plant inventory . The amount of credit given will
depend further up on the degree of salability of products accepted in opinion of Seller.
18 . PATENTS. Seller agrees to defend, and to protect Purchaser against loss or damage arising out of any legal action for patent infringement in
connection with the manufacture of its products sold to Purchaser, provided Seller is notified promptly of any such action with complete information and
is given an opportunity to defend.
19 . WARRANTY : LIMITATION OF LIABILITY. Seller warrants title to each individual product sold under this Contract and further warrants for a period
of twenty four (24 ) months from ship date, but only to the extent and limit of the purchase price paid for such individual product, that such product
conforms to the specifications set forth in the Contract and is free from defects in material and workmanship under normal service and use for which
it was designed. Seller’s sole obligation and Purchaser’s exclusive remedy under this warranty shall be limited to one of the following, as selected
by Seller: delivering to Purchaser a replacement for any product or part thereof determined by Seller to be defective, repairing such product or part,
or refunding the purchase price (or an equitable portion thereof) paid for such product or part by Purchaser. SELLER MAKES NO WARRANTY OF
FITNESS OR MERCHANTABILITY, AND NO OTHER WARRANTY, WHETHER EXPRESS OR ARISING BY OPERATION OF LAW, COURSE OF
DEALING, USAGE OF TRADE OR OTHERWISE IMPLIED SHALL EXIST IN CONNECTION WITH SELLER’S PRODUCTS OR ANY SALE OR USE
THERE OF. Purchaser must notify Seller promptly and within the warranty period of any claim under this warranty. Seller’s warranty extends only to the
first purchaser of a product from Seller or Seller’s authorized distributor. All goods not manufactured by Seller are warranted only to the extent of the
warranties of the original manufacturer. Seller disclaims any liability arising from tort, including strict liability , and Seller further disclaims any liability
(whether arising under this or any other provision of this Contract or otherwise) for any costs (including costs of removal or replacement), liabilities, lost
profits, loss of good will or any other general, special, incidental or consequential damages incurred by Purchaser in connection with this Contract or
any product purchased there under.
20 . LAW . This order shall be governed by and shall be construed by the law of the State of New York .
21 . GOVERNMENTAL REGULATIONS. Seller warrants that no code, law, regulation or ordinance of the United States, a state or any other
governmental authority or agency or any applicable Executive Order has been violated in the manufacture or sale of the items covered by this
Agreement and warrants that the equipment, supplies, and/or articles covered thereby conform with all such requirements.
22 . NUCLEAR FINANCIAL PROTECTION. Purchaser agrees to procure and maintain, as available to it, nuclear energy liability insurance, in a form
of policy approved by the Nuclear Regulatory Commission, and protection, as available, against liability for nuclear incidents not covered by such
insurance through an indemnity agreement, as provided in Section 170 of the Atomic Energy Act of 1954, as amended, or any succeeding comparable
statutory provision, and the regulations there under. Such financial protection shall be effective prior to the time any equipment purchased from us
is used or installed at or in connection with any nuclear facility and shall cover us an insured party . To the extent that such financial protection is not
suitable to Purchaser. Purchaser agrees to use its best efforts to cause such financial protection to be obtained by eligible parties. We will cooperate
with Purchaser and representatives of the nuclear energy insurance syndicates in complying with all underwriting requirements and with those
insurance recommendations which may be mutually agreed up on. Notwithstanding any representations or warranties made by us elsewhere in these
conditions of sale, we shall not be responsible for any bodily injury or property damage liability or any other public liability for any nuclear incidents,
whether or not in respect of or arising in connection with use or installation of our equipment at any nuclear facility or in connection with any such
facility . Purchaser hereby assumes any liability which might otherwise be imposed up on us and agrees to indemnify us and hold harmless from any
such liability and costs or expenses in connection therewith.
14
15
Parts & Accessories
pulsafeeder.com
A KOPkit (Keep On Pumping)
can help you cut downtime and
put you back in business fast.
Use KOPkits for preventive
maintenance and to ensure
continuous high performance
from your Pulsafeeder metering
pump.
Calibration Columns
These columns are constructed of clear PVC tubes
with PVC end caps or an
option
for
Borosilicate
glass with Teflon end caps
and should be sided for a
30-second draw down.
Pressure
Relief Valves
prevent an
overpressurization
situation from ever damaging
your pumps or pipes. Overpressurization can occur when
a valve is closed or a blockage
occurs. They are always recommended equipment for any
pump or skid system.
Pulsafeeder’s Pulsation
Dampeners improve pump
system efficiency by removing
pulsating flows from positive
displacement pumps.
Pressure Gauges are
relied on to measure pressure in the system. Proper
pressure is necessary to
insure flow. Pulsafeeder
Pressure Gauges are accurate and reliable.
PulsaLube is the only oil Pulsafeeder
recommends for use in metering and
transfer pumps. Pulsalube is a superior
blend of oils designed to provide optimal
lubrication and extend equipment life.
Back Pressure Valves provide positive back pressure
for systems with less than
the minimum required pressure difference between the
discharge and suction side of
the metering pump to assure
best metering performance.
PLM001 A16