250 0328
BOSS DB Series
IC502
IC504
C516
C517
HALLS
60/120
SW502
C501
TB504
FAULT
IL502
SO501
TACH IN
C4
C501
R501
IC507
IC501
+BUS
C507
C501
C508
C50
TH501
BUS LIMIT
SW501
C512
AC1
REV
FWD
MAXSPD
ACCEL
DECEL
MIN
SPD
IR
COMP
FWD
REV
TQLIM
OS
1.75 [44]
1
GA
1
L2
BR501
T501
* FUSE
Emergency
Stop Switch
BOSS SERIES DRIVE
0.73 [18]
115 or 230 VAC
BOSS DB
SERIES REGEN
DUMP CIRCUIT
or
100 - 320 VDC
FUSE
NOTE:
3.64 [92]
TB502
L501
L1
MODE
TP1
AC2
BOSSDB
www.minarikdrives.com
MINARIK DRIVES
South Beloit, IL 61080 -- u.S.A.
-VDC
C513
C511
C510
C518
C509
+VDC
-BUS
PWR ON
IL501
IL501
-BUS
+BUS
BOSSDB
C501
C4
QC503 QC502
www.minarikdrives.com
MINARIK DRIVES
South Beloit, IL 61080 -- u.S.A.
C515
2.45 [62]
Connect POS (+) to L1 and COM (-) to L2 when using a DC power source.
1.60 [40]
1.28 [33]
* NOTE: Do not add fuse to L2 unless input voltage is 230 VAC.
BOSSDB Series Regen Dump Circuit Connections
3.80 [97]
4.30 [109]
Regen Dump Circuit Connections
DC Power Source Connections
The regen dump circuit is recommended for all BOSS Series
drives. Regenerative loads may cause the bus voltage to
increase. The regen dump circuit prevents the voltage
across the bus capacitors from exceeding their voltage
rating.
If you use a DC power source with the regen dump circuit,
you must connect the power source to the BOSS drive L1
and L2 terminals as shown in the figure above.
1. Connect the +BUS terminal on the regen dump circuit to
the +VDC terminal on the BOSS drive motherboard.
2. Connect the -BUS terminal on the regen dump circuit to
the -VDC terminal on the BOSS drive motherboard.
BOSSDB Series Regen Dump Circuit Dimensions
All dimensions in Inches [Millimeters]
1. Connect the positive (+) lead from the DC power source
to the L1 terminal on the BOSS drive motherboard.
2. Connect the negative (or COM) lead from the DC power
source to the L2 terminal on the BOSS drive
motherboard.
Copyright 2006 by Minarik Drives - All rights reserved. No part of this manual may be reproduced or transmitted in any form without written permission from Minarik Drives. The information and technical
data in this manual are subject to change without notice. Minarik Corporation and its Divisions make no warranty of any kind with respect to this material, including, but not limited to, the implied warranties
of its merchantability and fitness for a given purpose. Minarik Corporation and its Divisions assume no responsibility for any errors that may appear in this manual and make no commitment to update or to
keep current the information in this manual.
MINARIK DRIVES
www.minarikdrives.com
Phone: (800) MINARIK (646-2745); Fax: (800) 394-6334
Document Number 250-0328, Revision 2; Printed in the U.S.A. – June 2006