4116-113
Standard Diagram
25
Brown
Brown
1
20
Brown
(2) Line Break
Limits
3
9
34
Heat Strip
2
Limit
Switch
7
4
Blue
3
9
B
A
Blk/Wht
13
T2 T1
1
L2
L1
Ladder Diagram
230/208-60-1
Power Source
Line 1 to
Power Source
Line 2 to
Power Source
22
32
Heat
Strip
2
Circuit Breaker 1
2 OR 26
30
230/208-60-1
Terminal Block
L1
L2
Ckt A
L2
L1
Ckt B
Circuit Breaker 2
Line 1 to
Power Source
Line 2 to
Power Source
Blue
T1
Heater
Contactor #1
2
L2
4
L1
Circuit
Breaker #2
T2
3
Heat
Line
Break
Strip
Limit
Circuit
Breaker #1
Ground
31 Lug
3
Emergency
Heat Relay
Red
Orange/Black
Red/Yellow
Black
6
4
4
9
7
6
Emergency Heat Relay
3
4
1
Line 1
3
Line 2
1
Line 1
Orange
2
2 6
1
Circuit
Breaker #1
11
3
Ground
Circuit
Breaker #2
10
6 Pin Plug for
Optional Heater Package
Line Break
Limit
6 Pin Plug for
Optional Heater
Package
Limit Switch
H. Contactor #1
Line 2
32
Blue
Brown
4
6
Emergency
Heat Relay
7
21
Brown
Brown
40
Heater Package
Assembly
! DANGER
*ELECTRICAL SHOCK HAZARD
*DISCONNECT POWER BEFORE
SERVICING.
Heater Contactor #1
15
Blue
Black/White
4116-113
! WARNING
USE COPPER CONDUCTORS
ONLY SUITABLE FOR AT LEAST
75° C.