advertisement
SSP-350-X-128-ISSUE4.0
SERVICE MANUAL
FOR
MODEL SSP-350-X-128
WALL MOUNT
PRISON VISITATION TELEPHONE
Communication Equipment
& Engineering Company
Serving the Telephone Industry Since 1930
519 West South Park Street
Okeechobee, FL. 34972
Voice: 863-357-0798
Fax: 863-357-0006
IMPORTANT INFORMATION
FOR
CUSTOMER
Please fill in before you continue.
The following information is necessary when calling CEECO for assistance.
MODEL NUMBER
SERIAL NUMBER
MODEL SSP-350-X-128 PRISON
VISITATION TELEPHONE.
DATE MANUFACTURED
LOCATION INSTALLED
For us to better serve you, please have this information available when calling for technical support.
CEECO
Communication Equipment & Engineering Company
519 West South Park Street
Okeechobee, FL. 34972
(863) 357-0798 Voice
(863) 357-0006 Fax
ISSUE 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
2
ISSUE 4.0
TABLE OF CONTENTS
SECTION PAGE
1.0 INTRODUCTION................................................................................................... 4
2.0 GENERAL DESCRIPTION .................................................................................. 4
3.0 OPERATION .......................................................................................................... 4
4.0 RECOMMENDED TOOLS AND TEST EQUIPMENT .................................... 4
5.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS ..................... 5
6.0 TESTING ................................................................................................................. 6
7.0 SPECIFICATIONS................................................................................................. 6
8.0 PARTS LIST ........................................................................................................... 7
9.0 REPAIR AND RETURN INFORMATION ......................................................... 8
10.0 WARRANTY POLICY .......................................................................................... 9
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
3
ISSUE 4.0
1.0 INTRODUCTION
The practices in this manual provide installation and maintenance information for
Model SSP 350-X-128 Stainless Steel Panel Visitation Phone.
The information in this manual is subject to change without notification.
For information not included in this manual, please call or write:
CEECO
Customer Service
519 West South Park Street
Okeechobee, FL. 34972
(863) 357-0798
(863) 357-0006 FAX
2.0 GENERAL DESCRIPTION
The CEECO Model SSP-350-X-128 is a Ring-Down Telephone designed for special-purpose applications that require a Vandal Resistant yet attractive telephone.
3.0 OPERATION
Lift the handset and normal conversation will follow. Upon completion of call return handset to cradle.
4.0 RECOMMENDED TOOLS AND TEST EQUIPMENT
Volt/Ohm Meter
1/4" Nut Driver
Flat Blade Screw Driver
Security Tool, CEECO Part Number 301-064 (sold separately)
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
4
ISSUE 4.0
5.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS
5.1 The power supply is intended to run off of an 110v line and comes with a
3-prong grounding plug. The 110v outlet must be grounded, or a separate ground wire should be run from the individual phone units to a suitable ground. Plug the power supply into an 110v outlet and install the power supply in the desired location. The selected location must be out of reach for users. *Grounding and installation must be in accordance with all
applicable local and national electrical and building codes.
5.2 Determine the desired mounting locations for the RJ11C modular jack/interface units. Run the green and red (tip and ring) wires with the modular jacks/interfaces to those locations. Mount the jacks/interfaces as desired.
5.3 The SSP-350-X-128 is designed to fit into a standard double-gang masonry style mounting box (provided) and is equipped with a modular cord. Determine the desired routing path for the modular cords and make the appropriate knock out holes on the mounting boxes. Install the mounting boxes as desired.
5.4 Run the modular cords through the knock out holes in the mounting boxes.
Mount the telephone units, utilizing the security screws provided, to the mounting boxes. The security tool, which is sold separately, must be used for the security screws.
5.5 Plug the modular cords into the modular jacks/interfaces. The phone units plugged into the same modular jack will allow talk paths to one another. If more length is needed for the modular cords, a simple in-line coupler is recommended. A section of modular-to-modular line cord can then be used to bridge the desired distance. The coupler and line cord can be purchased at a typical electronic supply store.
5.6 The phone units must be plugged in with the power supply on for a few minutes, before they will fully function.
***** WARNING *****
A. Never install telephone wiring during a lightning storm.
B. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
C. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
D. Use caution when installing or modifying telephone lines.
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
5
ISSUE 4.0
6.0 TESTING
6.1 Once installation has been completed, allow the phones to rest on-hook a few minutes, with the power supply on.
6.2 Lift the handsets of the units that are intended to talk to one another.
Determine that normal conversation is allowed. If so, return the handsets to the cradles. The phone units are ready for use.
6.3 If normal conversation does not take place, please review the installation steps. Make a visual check to ensure that all wires and connectors are as they should be. Remember that the phone units, which are connected to the same modular jack, will allow talk paths to one another. A phone connected to one jack/interface cannot talk to a phone connected to another jack/interface. The modular jacks/interfaces that are provided must be used, as they are modified to work in conjunction with the power supply.
6.4 Once it has been determined that the installation and connections are correct, and if trouble is still experienced, please refer to section 9.2 of this manual.
7.0 SPECIFICATIONS
INPUT POWER: C.O. Line powered or Talk battery (power supply)
LOOP CURRENT:
IMPEDANCE:
HEARING AID
COMPATIBLE:
ENVIRONMENTAL:
TELEPHONE COVER:
DIMENSIONS:
MOUNTING:
WEIGHT:
FCC REGISTRATION:
23 ma min. to 80 ma max.
600 ohms
Meets EIA standards
Temperature 0° C to 50° C
Humidity 20%-90% non-condensating
Brushed 16 ga. Stainless Steel
4.5" Wide x 4.5" High x 4.5" Deep
(Handset On-hook)
Standard double gang electrical box
Approximately 3 lb.
BW-88T7-13716-TE-T
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
6
8.0 PARTS LIST
QUANTITY PART NUMBER DESCRIPTION
1
1
1
1
1
2
1
OPTIONS:
1
1
1
301-591
301-004-32
301-009
301-018
301-005
331-006
Standard
301-064
350-255
350-250
Magnetic Hook Switch
Handset with Armored Cord
Network
Line Cord
Ferrule
#8-32 x 3/8" Security Screw
(2 screws are needed per unit)
DBL Gang Wall Mount Box
Security Tool (for screw above)
Power Supply
Interface Jack (1 per pair)
ISSUE 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
7
ISSUE 4.0
9.0 REPAIR AND RETURN INFORMATION
9.1 WARRANTY REPAIR
Any device returned requiring warranty service; repair or credit must be accompanied with a "Return Material Authorization" (RMA) Form. It must include: return-shipping instructions, original purchase order number and special marking instruction. A description of the trouble observed must be attached to the defective unit. This information must be inside the shipping container.
9.2 DIRECT ALL INQUIRES TO:
CEECO
Repair Department
519 West South Park Street
Okeechobee, FL. 34972
(863) 357-0798
9.3 NON-WARRANTY REPAIR
CEECO will repair equipment out of warranty for a set charge plus parts.
The customer must pay the shipping costs both directions.
9.4 RETURN FOR CREDIT
Material may be returned for credit only with prior approval. Material authorized for return is subject to a 20% restocking charge based on the manufacturer's list price. Return RMA must be requested no later than 30 days after original shipment.
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
8
ISSUE 4.0
10.0 WARRANTY POLICY
10.1 GENERAL
CEECO products are guaranteed to be free of defects in material and workmanship for a period of 365 days from the date of original purchase.
CEECO's obligation under this warranty is limited to repair or replacement of any part found to be defective by CEECO. Under no circumstances shall CEECO be liable for loss, damage, and cost of repair or consequential damages of any kind, which have been caused by neglect, abuse, acts of God or improper operation of equipment. This warranty is limited to the value of material only.
10.2 PRINTED CIRCUIT BOARDS
Printed circuit boards should not be field repaired. If a unit is found to be faulty, replace it with another unit and return the faulty unit to CEECO for repair. Modifications by any one other than CEECO will void the warranty.
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
9
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project