B209B

B209B
ACME ENGINEERING & MANUFACTURING CORP.
P.O. Box 978, Muskogee, OK 74402
Phone: 918/682-7791 Fax: 800/382-2263
www.acmeag.com e-mail: [email protected]
www.acmehort.com e-mail: [email protected]
COOLING
KOOL-CEL®
CTC, OTC, CTPP & OTPP
ACME EVAPORATIVE COOLING SYSTEMS
FOR 6 INCH PADS
FEATURES
•
•
•
UV PROTECTED GUTTER
EASY INSTALLATION
LOW MAINTENANCE
•
•
STAINLESS STEEL TOP
•
SYSTEM SEALS TO BUILDING - NO
ADDITIONAL PARTS
NO ADDITIONAL WATER STORAGE
TANK
DESCRIPTION
Acme’s Kool-Cel Systems provide a rugged PVC and Stainless Steel housing for the
Evaporative Cooling Pads. The Acme Evaporative Cooling Systems offer the optimal in
installation ease and maintenance. Gutters with UV protection will give many years of trouble
free operation. ACME offers two unique top systems with two unique gutters. All systems are
interchangeable. The Closed Top System or Open Top System will work with either the
Continuous Gutter or 8" PVC Pipe Gutter. Both gutter systems are designed to seal against
the building without the addition of furring strips or flashing. Gutter supports are heavy gauge
galvanized and all fasteners are stainless steel or hot dipped galvanized. Heavy gauge
aluminum end caps are available.
CLOSED TOP SYSTEM
•
•
•
•
PAD TOP ENCLOSED
STAINLESS STEEL TOP
HEAVY GAUGE ALUMINUM END CAPS
PADS SECURELY HELD TO BUILDING
The Closed Top System is
designed to keep debris
from entering the top of the
Kool-Cel System. This top
can be used with either the
Continuous Gutter shown
below or the 8-inch PVC
Pipe System on the next
page.
CONTINUOUS GUTTER
•
•
•
•
•
•
BLACK GEO-MEMBRANE MATERIAL
EASY TO INSTALL
FLEXIBLE
NO SEAMS
SNAP IN PVC PAD SUPPORT WITH DRIP LEDGE
REMOVABLE END CAP FOR EASY CLEAN OUT
The gutter is a heavy gauge geo-membrane material supplied in one piece. The removable
clamped-on ends allow for easy gutter cleaning. The black color minimizes algae growth and
has UV inhibitors. All pad weight is supported by the heavy galvanized wall brackets not the
gutter material. The sump tank is attached directly to the end of the gutter. Fasteners supplied
with the continuous gutter are either hot dipped galvanized steel or stainless steel.
OPEN TOP SYSTEM
•
•
•
•
•
VISIBLE DISTRIBUTION PIPE
STAINLESS STEEL TOP
HEAVY GAUGE ALUMINUM END CAPS
EASY MAINTENANCE
PADS SECURELY HELD TO BUILDING
The new Open Top System
allows for easy inspection of the
Water Distribution System. Any
clogged hole can be cleaned
without major system
disassembly. This Open Top
System can be used either with
the 8-inch PVC Pipe System
shown below or with the
Continuous Gutter System
shown on the previous page.
8 INCH PVC PIPE GUTTER
•
•
•
•
•
UV PROTECTED
EASY TO INSTALL
SNAP IN PVC PAD SUPPORT WITH DRIP LEDGE
PIPE IS PRE-MARKED FOR EASY CUT OUT
REMOVABLE END CAP FOR EASY CLEAN OUT
The 8-inch pipe gutter is supplied in 5' and 10' lengths, pre-marked for the pad cutout. The
pads are supported by PVC pad supports that snap directly into the 8" pipe gutter. Heavy
galvanized brackets hold the pipe to the house wall. The sump pump is located in a 12" PVC
“T” section connected to the end of the 8" pipe. The fasteners needed to mount the gutter are
hot dipped galvanized lag bolts supplied with the assembly.
PLUMBING COMPLETER KITS
PUMPS
Size
Voltage
HP
Capacity
10' Head
Capacity
15' Head
10S
115
1/6
16 GPM
13 GPM
15S
115
3/10
29 GPM
12 GPM
30S
115 or 230
1/3
45 GPM
33 GPM
60S
115 or 230
1/2
67 GPM
52 GPM
90S
230
3/4
84 GPM
75 GPM
LPS07
115 or 230
3/4
58 GPM
53 GPM
WATER VALVES
Standard “T” Tank
Tank Shown with
Right End Open
STANDARD
HIGH VOLUME
ORDER INFORMATION
CONTINUOUS GUTTER
Optional 8-Inch “T” Adaptor
Tank Shown with
Both Ends Open
1. Specify Length - 5 to 80 feet in 1 foot
increments
2. Specify Tank - left, right, or both open,
or 50 gal.
3. Specify Pump - size and voltage
4. Specify Water Valve
5. Specify Endcovers - pad height
8-INCH PIPE GUTTER
50-Gallon Tank with Plumbing Adaptor
LIMITED WARRANTY Acme Engineering and
Manufacturing Corporation extends this limited
warranty to the original purchaser and warrants
that products described herein shall be free from
original defects in workmanship and materials
for two years from date of shipment (except for
Acme’s exclusive duplex split pillow block
bearings and shaft 5 years from shipment, belts
one year from shipment, and polyethylene
tubing at 90 days from shipping, AIR40 Heater
warranty one year from date of shipment, AIR40
Emitter warranty three years from date of
shipment and DDP fan lifetime warranty on its
propeller, cone, and housing), provided same
have been properly handled, stored, installed,
serviced, maintained and operated. Refer to
Form MS149 for complete limited warranty
terms and conditions. This form is available to
anyone at www.acmefan.com. The Company's
warranty is in lieu of all other warranties, express
or implied, arising by law or otherwise, including
without limitation the implied warranties of
1. Specify Length - 5 to 80 feet in 1 foot
increments
2. Specify Tank - “T” type or 50 gal
3. Add T Adaptor if needed
4. Specify Water Valve
5. Specify Pump - size and voltage
6. Specify End Covers - pad height
merchantability and fitness for a particular
purpose, which are hereby expressly disclaimed
claimed and waived.
Acme products are designed and manufactured
to provide reliable performance but they are not
guaranteed to be 100% free of defects. Even
reliable products will experience occasional
failures and this possibility should be recognized
by the Purchaser and End User. If these
products are used in a life support ventilation
system where failure could result in loss or
injury, the Purchaser and End User should
provide
adequate
back-up
ventilation,
supplementary natural ventilation or failure
alarm system, or acknowledge willingness to
accept the risk of such loss or injury.
WARNING DO NOT use in HAZARDOUS
ENVIRONMENTS where fan’s electrical system
could provide ignition to combustible or
flammable materials unless unit is specifically
built for hazardous environments. Comply with
all local and national safety codes including the
National Electrical Code (NEC) and National
ACME ENGINEERING &
MANUFACTURING CORP.
P.O. Box 978, Muskogee, Oklahoma 74402
Telephone: 918-682-7791 Fax: 918-682-0134
www.acmeag.com e-mail: [email protected]
www.acmehort.com e-mail: [email protected]
Fire Protection Act (NFPA). Guards must be
installed when fan is within reach of personnel or
within seven (7) feet (2.134 m) of working level
or when deemed advisable for safety.
DISCLAIMER The Company has made a
diligent effort to illustrate and describe the
products in this literature accurately; however,
such illustrations and descriptions are for the
sole purpose of identification, and do not
express or imply a warranty that the products
are merchantable, or fit for a particular purpose.
INDEMNITY Purchaser acknowledges various
warnings by the Company regarding the
products and its installation and use. If the
Company incurs any claims, lawsuits,
settlements, or expenses (including attorney
fees) for any loss, injury, death or property
damage including, but not limited to, claims
arising out of the Purchaser’s or any end user’s
installation or use of the products, the Purchaser
shall indemnify and hold the Company
harmless.