Crestron TPS-CBL-T manual

Add to my manuals

advertisement

Crestron TPS-CBL-T manual | Manualzz

This document was prepared and written by the Technical Documentation department at:

Crestron Electronics, Inc.

15 Volvo Drive

Rockleigh, NJ 07647

1-888-CRESTRON

Crestron TPS-CBL-T3/6/9 Triamese Cable for TPS/Tilt Panel

Contents

Triamese Cable for TPS/Tilt Panel: TPS-CBL-T3/6/9 1

Description 1

Functional Description

Physical Description

Cable/Port Signals

1

2

3

Cable Connections

Further Inquiries

Future Updates

4

6

6

Return and Warranty Policies

Merchandise Returns / Repair Service

CRESTRON Limited Warranty

7

7

7

Installation Guide - DOC. 6008 Contents • i

Crestron TPS-CBL-T3/6/9 Triamese Cable for TPS/Tilt Panel

Triamese Cable for TPS/Tilt Panel:

TPS-CBL-T3/6/9

Description

Functional Description

The TPS-CBL-T3/6/9 Triamese (three shielded cables joined together) cable is an optional feature designed for Crestron’s Isys™ TPS-5000 and

TPS-6000 tilt touchpanels. The Triamese cable is used for connection to touchpanel NET/VIDEO, RGB video, and AUDIO ports and are available in 3-, 6-, and 9-foot versions.

When a TPS touchpanel is equipped with optional TPS-VID Video Card and TPS-XVGA-BV RGB Computer Interface Card with Balanced

Video, individual cables (including a cable for the audio input) are required. The Triamese cable minimizes the number of individual cables attached to the touchpanel. Supplied with the TPS-XVGA-BV card is a

TPS-IMC-BV Interface Module that serves as an interface between the touchpanel and the video source computer and/or the Crestron remote control system (herein referred to as the Cresnet system). Also supplied with the TPS-XVGA-BV is a 15-foot (4.57 meter) Triamese cable. The

TPS-CBL-T3/6/9 cable is available to provide optional lengths.

NOTE: For general information about the TPS-IMC-BV, consult its

Operations Guide (Doc. 5921). The latest revision can be obtained from the Products page (PRODUCT MANUALS section, hardware section) or

Downloads page (MANUAL Library) of Crestron’s website

(www.crestron.com). New users are required to register to obtain access to the FTP site.

Installation Guide - DOC. 6008 Triamese Cable for TPS/Tilt Panel: TPS-CBL-T3/6/9 • 1

Triamese Cable for TPS/Tilt Panel Crestron TPS-CBL-T3/6/9

Physical Description

The TPS-CBL-T3/6/9 Triamese cable contains two 10-pin plugs for

NET/VIDEO, two 10-pin plugs for RGB video, and two 8-pin plugs for

AUDIO connections. For descriptions of the Triamese cables, refer to the diagram below.

Triamese Cable View

VERSION LENGTH

TPS-CBL-T3 3 ft (0.91 m)

TPS-CBL-T6 6 ft (1.83 m)

TPS-CBL-T9 9 ft (2.74 m)

NET

/VIDEO

RGB

AUDI

O

PIN 1 *

(TAB IS FACING AWAY)

10-PIN

NET/VIDEO *

PLUGS

10-PIN

RGB *

PLUGS

8-PIN

AUDIO *

PLUGS

* For the pin signals,

refer to "Cable/Port Signals"

on the next page.

NET

/VIDEO

RGB

AUDI

O

2 • Triamese Cable for TPS/Tilt Panel: TPS-CBL-T3/6/9 Installation Guide - DOC. 6008

Crestron TPS-CBL-T3/6/9 Triamese Cable for TPS/Tilt Panel

Cable/Port Signals

For the TPS-CBL-T3/6/9 Triamese cable/port signals, refer to the tables below.

NET/VIDEO Plug Pin-Outs

PIN

6

7

4

5

8

1

2

3

9

10

DESIGNATION

+24V

GND

C+

C-

Y

Z

Y+

Y-

GND

+24V

DESCRIPTION

Power (Network)

Ground (Network)

Chrominance (Positive)

Chrominance (Negative)

Data (Network)

Data (Network)

Luminance (Positive)/Composite

Luminance (Negative)/Composite

Ground (Network)

Power (Network)

RGB Plug Pin-Outs

PIN

1

2

5

6

7

3

4

8

9

DESIGNATION

V-

H-

R-

R+

G-

G+

B-

B+

H+

10 V+

DESCRIPTION

Vertical sync (Negative)

Horizontal sync (Negative)

RED video (Negative)

RED video (Positive)

GREEN video (Negative)

GREEN video (Positive)

BLUE video (Negative)

BLUE video (Positive)

Horizontal (Positive) or

Composite sync

Vertical sync (Positive)

Installation Guide - DOC. 6008 Triamese Cable for TPS/Tilt Panel: TPS-CBL-T3/6/9 • 3

Triamese Cable for TPS/Tilt Panel

AUDIO Plug Pin-Outs

PIN

1

6

7

8

4

5

2

3

DESIGNATION

L+

L-

S

R+

R-

S

M+

M-

Crestron TPS-CBL-T3/6/9

DESCRIPTION

Left Input (Positive)

Left Input (Negative)

Shield

Right Input (Positive)

Right Input (Negative)

Shield

Microphone Output (Positive)

Microphone Output (Negative)

Cable Connections

NOTE: When connecting the video and RGB video from the

TPS-XVGA-BV Interface Module to the touchpanel, exceeding cable lengths of 30-feet will significantly degrade the signals. To maintain highquality images, DO NOT daisy-chain cables, Crestron TPS-BLOCK devices or fabricate cables longer than 30-feet. For further information about TPS-BLOCK devices, consult an appropriate installation guide that can be obtained from the Products page (PRODUCT MANUALS section, hardware section) or Downloads page (MANUAL Library) of Crestron’s website (www.crestron.com). New users are required to register to obtain access to the FTP site.

NOTE: To display video from the TPS-VID, power MUST be connected to the TPS-IMC-BV. An external power pack may be connected to the interface module to supplement Cresnet power or if Cresnet power is not available.

4 • Triamese Cable for TPS/Tilt Panel: TPS-CBL-T3/6/9 Installation Guide - DOC. 6008

Crestron TPS-CBL-T3/6/9 Triamese Cable for TPS/Tilt Panel

1. Refer to the diagram below. At the rear of the touchpanel base, attach the TPS-CBL-T3/6/9 Triamese cable plug labeled

AUDIO to the AUDIO port, the RGB plug to the RGB port, and the plug labeled NET/VIDEO to the NET/VIDEO port.

Attach Triamese Cable Plugs to Touchpanel

HEADPHONES

AUDIO

RS-232

NET/VIDEO

LAN 24VDC 2.0A

AUDIO

PLUG

RGB

PLUG

NET/VIDEO

PLUG

TRIAMESE

CABLE

2. Refer to the diagram below. At the TPS-IMC-BV ports labeled

TO PANEL, attach the Triamese cable plug labeled

NET/VIDEO to the NET/VIDEO port, the plug labeled RGB to the RGB port, and the plug labeled AUDIO to the AUDIO port.

Attach Triamese Cable Plugs to TPS-IMC-BV

B RG G Z

T

Y

NE

24 A

DC

2.0

24V

ED NC

EO

BALA

VID

EO VID AL

C

SC/P NT

MP

Y

CO

TRIAMESE

CABLE

CRESTRON

TPS-IMC-BV

BAL COAX

TO PANEL

NET/

VIDEO RGB AUDIO

AUDIO

INPUT S

R

+

AUDIO

INPUT

+

L

S

MIC

OUT

+ S

Installation Guide - DOC. 6008

NET/VIDEO

PLUG

RGB

PLUG

AUDIO

PLUG

Triamese Cable for TPS/Tilt Panel: TPS-CBL-T3/6/9 • 5

Triamese Cable for TPS/Tilt Panel Crestron TPS-CBL-T3/6/9

Further Inquiries

If after reviewing this Installation Guide, you cannot locate specific information or have questions, please take advantage of Crestron's award winning customer service team by calling:

• In the US and Canada, call Crestron’s corporate headquarters at

1-888-CRESTRON [1-888-273-7876] or 1-201-767-3400.

• In Europe, call Crestron International at +32-15-50-99-50.

• In Asia, call Crestron Asia at +852-2341-2016.

• In Latin America, call Crestron Latin America at

+525-260-4336.

For local support from exclusive Crestron factory-trained personnel call:

• In Australia, call Soundcorp at +613-9488-1555.

• In New Zealand, call Amber Technologies at +649-410-8382.

Future Updates

As Crestron improves functions, adds new features, and extends the capabilities of the TPS-CBL-T3/6/9, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.

The Downloads page of the Crestron website (www.crestron.com) directs the reader to the location and description of each update. Check the site periodically for update availability and its subjective value. New users are required to register in order to obtain access to the FTP site.

6 • Triamese Cable for TPS/Tilt Panel: TPS-CBL-T3/6/9 Installation Guide - DOC. 6008

Crestron TPS-CBL-T3/6/9 Triamese Cable for TPS/Tilt Panel

Return and Warranty Policies

Merchandise Returns / Repair Service

1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise

Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address.

2. Products may be returned for credit, exchange, or service with a CRESTRON

Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, Cresskill, N.J., or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons.

Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee, plus shipping costs, on any products returned with an RMA.

3. Return freight charges following repair of items under warranty shall be paid by

CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.

CRESTRON Limited Warranty

CRESTRON ELECTRONICS, Inc. warrants its Cresnet products, denoted by a "CN" prefix model number, to be free from manufacturing defects in materials and workmanship for a period of three (3) years from the date of shipment to purchaser. Disk drives and any other moving or rotating mechanical parts are covered for a period of one (1) year. CRESTRON warrants all its other products for a period of one year from the defects mentioned above, excluding touchscreen display components which are covered for 90 days. Incandescent lamps are completely excluded from Crestron's Limited Warranty. CRESTRON shall, at its option, repair or replace any product found defective without charge for parts or labor.

Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty.

CRESTRON shall not be liable to honor warranty terms if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced, or removed.

This warranty shall be the sole and exclusive remedy to the purchaser. In no event shall

CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON makes no other warranties nor authorizes any other party to offer any warranty, expressed or implied, including warranties of merchantability for this product. This warranty statement supersedes all previous warranties.

Trademark Information

All brand names, product names, and trademarks are the sole property of their respective owners. Windows is a registered trademark of Microsoft Corporation. Windows 95/98/Me/XP and Windows NT/2000 are trademarks of

Microsoft Corporation.

Installation Guide - DOC. 6008 Triamese Cable for TPS/Tilt Panel: TPS-CBL-T3/6/9 • 7

Crestron Electronics, Inc.

15 Volvo Drive Rockleigh, NJ 07647

Tel: 888.CRESTRON

Fax: 201.767.7576 www.crestron.com

Installation Guide - DOC. 6008

12.01

Specifications subject to change without notice.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement