MODEL: SVB (wide-output) Functions & Features • Converts a DC input into a standard process signal • Isolation up to 2000 V AC • Fast response type available • LCD meter • Max. 30 V output available • Load resistance 1500 Ω (20 mA output) • High-density mounting Z: Specify current (See INPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Input resistance 10 kΩ min.) 15: 0 – 50 mV DC (Input resistance 10 kΩ min.) 16: 0 – 60 mV DC (Input resistance 10 kΩ min.) 2: 0 – 100 mV DC (Input resistance 100 kΩ min.) 3: 0 – 1 V DC (Input resistance 1 MΩ min.) 4: 0 – 10 V DC (Input resistance 1 MΩ min.) 5: 0 – 5 V DC (Input resistance 1 MΩ min.) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) 4W: -10 – +10 V DC (Input resistance 1 MΩ min.) 5W: -5 – +5 V DC (Input resistance 1 MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) Typical Applications • Isolation between control room and field instrumentation [2] OUTPUT Plug-in Signal Conditioners M-UNIT SIGNAL TRANSMITTER 50 (1.97) 80 (3.15) 127 (5) mm (inch) MODEL: SVB–[1][2]–[3][4] ORDERING INFORMATION • Code number: SVB-[1][2]-[3][4] Specify a code from below for each [1] through [4]. (e.g. SVB-6A-M2/E/K) • Special input and output ranges (For codes Z & 0) [1] INPUT Current A: 4 – 20 mA DC (Input resistance 250 Ω) A1: 4 – 20 mA DC (Input resistance 50 Ω) B: 2 – 10 mA DC (Input resistance 500 Ω) C: 1 – 5 mA DC (Input resistance 1000 Ω) D: 0 – 20 mA DC (Input resistance 50 Ω) E: 0 – 16 mA DC (Input resistance 62.5 Ω) F: 0 – 10 mA DC (Input resistance 100 Ω) G: 0 – 1 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 100 Ω) J: 0 – 10 μA DC (Input resistance 1000 Ω) K: 0 – 100 μA DC (Input resistance 1000 Ω) GW: -1 – +1 mA DC (Input resistance 1000 Ω) FW: -10 – +10 mA DC (Input resistance 100 Ω) http://www.m-system.co.jp/ Current A: 4 – 20 mA DC (Load resistance 750 - 1500 Ω) B: 2 – 10 mA DC (Load resistance 1500 - 3000 Ω) C: 1 – 5 mA DC (Load resistance 3000 - 6000 Ω) D: 0 – 20 mA DC (Load resistance 750 - 1500 Ω) E: 0 – 16 mA DC (Load resistance 935 - 1875 Ω) F: 0 – 10 mA DC (Load resistance 1500 - 3000 Ω) G: 0 – 1 mA DC (Load resistance 15k - 30kΩ) DW: -20 – +20 mA DC (Load resistance 500 - 1000Ω) FW: -10 – +10 mA DC (Load resistance 1000 - 2000Ω) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 8: 0 – 20 V DC (Load resistance 2000 Ω min.) 9: 0 – 30 V DC (Load resistance 3000 Ω min.) 8W: -20 – +20 V DC (Load resistance 2000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) Caution: The load resistance must be within the indicated range for adequate operation. [3] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [4] OPTIONS (multiple selections) Input Signal Indicator blank: Without /E: With (0.0 - 100.0 % display) Response Time (0 – 90 %) blank: Standard (≤ 0.5 sec.) /K: Fast Response (≤ 25 msec.) Standards & Approvals blank: Without CE SVB SPECIFICATIONS ES-1307 Rev.1 Page 1/3 MODEL: SVB /CE: CE marking (Not selectable with /E) PERFORMANCE in percentage of span GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Screw terminal: Chromated steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Overrange output: Approx. -10 to +110 % at 0 – 20 V Zero adjustment: -2 to +2 % (front) Span adjustment: 98 to 102 % (front) INPUT SPECIFICATIONS ■ DC Current: Shunt resistor attached to the input terminals (0.5 W) Specify input resistance value for code Z. ■ DC Voltage: -300 – +300 V DC Minimum span: 10 mV Offset: Max. 1.5 times span Input resistance Span 10 – 100 mV : ≥ 10 kΩ Span 0.1 – 1 V : ≥ 100 kΩ Span ≥ 1 V : ≥ 1 MΩ Accuracy: ±0.1 % Display accuracy: ±(0.1 % of FS + 1 digit) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 Low Voltage Directive (2006/95/EC) EN 61010-1: 2001 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) OUTPUT SPECIFICATIONS ■ DC Current: -20 – +20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 30 V max. and 15 V min.; 20 V max. and 10 V min. (0 % output = negative value) ■ DC Voltage: -20 – + 30 V DC (The 0 – 100 % output range values within -10 – +12 V range are not available.) Minimum span: 10 V Offset: Max. 1.5 times span Load resistance: Output drive 10 mA max. INSTALLATION Power Consumption •AC: Approx. 5 VA at 100 V Approx. 6 VA at 200 V Approx. 7 VA at 264 V •DC: Approx. 3 W Operating temperature: -5 to +60°C (23 to 140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lbs) http://www.m-system.co.jp/ SVB SPECIFICATIONS ES-1307 Rev.1 Page 2/3 MODEL: SVB DIMENSIONS unit: mm (inch) CLAMP (top & bottom) 20 (.79) 7.8 (.31) 5 4 3 7 8 1 2 2–4.5 (.18) dia. MTG HOLE 15 (.59) deep 8–M3.5 SCREW 50 (1.97) 6 80 (3.15) 80 (3.15) 35.4 (1.39) DIN RAIL 35mm wide 107 (4.21) 40 (1.57) 127 (5) [3.3 (.13)] 50 (1.97) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) 6 5 4 3 7 8 1 2 12 (.47) INPUT RESISTOR (model: REM) Input shunt resistor attached for current input. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM ** Isolation + R INPUT – * 3 Low Drift Amplifier Z S Output Driver 1 + OUTPUT 4 2 – 5 7 U(+) 6 8 V(–) POWER Base Socket *Input shunt resistor attached for current input. **Option /E Specifications are subject to change without notice. http://www.m-system.co.jp/ SVB SPECIFICATIONS ES-1307 Rev.1 Page 3/3
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement