BL Application Guide v2.0
BL
Application
Guide
Version 2.0
Overview Guide
DeviceNet™
EtherNet/IP™
Profibus ®
Profinet ®
CANopen
Modbus TCP/IP
www.turck.us
How To
Connect BL67 to Valve Banks...
1
Possible Valve Bank Combinations
BL67 I/O System can include
digital, analog and RFID.
16DO-0.1A-P
2
...With Molded Cables & Discrete Outputs
The 16-channel BL67-16DO-0.1A output
module was specially developed for switching
valve banks. It features:
• Channel-related short-circuit monitoring
Manufacturer
Valve Bank P/N
I/O Slice (1)
Base (2)
Cordset (3)
SMC
SS5Q13-08FD0-D
BL67-16DO-0.1A-P
BL67-B-1M23-19
CSWM DB25 19-17-*/SMC
FESTO
197 334 MH1-A-24VDC-D-PI-16V-PRA-SE
BL67-16DO-0.1A-P
BL67-B-1M23-19
CSWM DBK25 19-17-*/FESTO
FESTO
539105 32E-MPM-E
BL67-8DO-0.5A-P
BL67-B-1M23
CSWM DBK25 12-9-*/FESTO
MAC
EBM800A-001A-16
BL67-16DO-0.1A-P
BL67-B-1M23-19
CSWM DBK25 19-17-*/MAC
MAC
EBM800A-002A-04
BL67-8DO-0.5A-P
BL67-B-1M23
CSWM DBK25 12-9-*/MAC
Other combinations available. Please contact TURCK for assistance.
* Indicates length in meters.
• Wire-break detection
• Configurable current monitoring
• Connection of multiple valve banks from different manufacturers
• Integration of valve banks with digital output modules with 4, 8 or 16 channels
• Base modules with 12 or 19-pin M23 male connectors
• Soldered or crimped connection using prefabricated M23 plugs
3
• Molded M23 cordsets are available with open end or valve connector
• Standard and custom cordset lengths
The BL67 system can connect to valves made by any manufacturer and any model, provided it uses
discrete inputs to control the valve bank. Please contact our factory for assistance at 1-800-544-7769.
Wire-break and short-circuit monitoring
may be activated with standard module
configuration, as well as setting the
parameters for current monitoring.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
How To
Connect BL67 to Valve Banks...
The BL67-1CVI module was developed so
CANopen enabled valve banks could be
used within any available fieldbus.
It features:
• Monitoring of individual nodes
with configurable watchdog timer
The available parameters per CANopen
node are:
...Via
Subbus
Possible Valve Bank Combinations
• Use of standard M12-CANopen/
DeviceNet fieldbus cable
• Node active/inactive
Manufacturer
Valve Bank P/N
I/O Slice (1)
Base (2)
Cordset (3)
• Integration of CANopen valve
banks from different manufacturers
• Guarding active/inactive
FESTO
539217 50E-F14GA-S
BL67-1CVI
BL67-B-1M12
RSC RKC 572-*M
• 8 bytes of input data and 8 bytes of output data may be configured
• Number of input bits (4, 8...32 bit)
FESTO
539217 50E-F14GB-S
BL67-1CVI
BL67-B-1M12
RSC CBC5 572-*M
• No special CANopen knowledge required
• Number of output bits
(4, 8...32 bit)
Norgren
• The parameters can be set in the master using configuration files, such as GSD, GSDML, or EDS VS18 Series
BL67-1CVI
BL67-B-1M12
RSC RKC 572-*M
•
Use of any available BL67 gateway to bring the CANopen data onto other fieldbuses (DeviceNet™, EtherNet/IP™, Profibus®, Profinet ®, Modbus TCP/IP, CANopen)
Other combinations available. Please contact TURCK for assistance.
* Indicates length in meters.
CANopen Media Combinations
1
BL67 I/O System can include
Digital, Analog, RFID,...
1CVI
RSC
RKC
WSC
WKC
RSC CBC5 57x-*M
RKC CBC5 57x-*M
WSC CBC5 57x-*M
WKC CBC5 57x-*M
RSC DB9F 57x-*M
RKC DB9F 57x-*M
WSC DB9F 57x-*M
WKC DB9F 57x-*M
RSC DB9S 57x-*M
RKC DB9S 57x-*M
WSC DB9S 57x-*M
WKC DB9S 57x-*M
RSC RSC 57x-*M
RSC RKC 57x-*M
RSC WSC 57x-*M
RSC WKC 57x-*M
RSC RKC 57x-*M
RKC RKC 57x-*M
WSC RKC 57x-*M
RKC WKC 57x-*M
CBC5
2
DB9F
The parameters may also be set using
TURCK’s free I/Oassistant software tool.
DB9S
RSC
RKC
3
Other combinations available. Please contact TURCK for assistance.
* Indicates length in meters.
The BL67 system can connect to any valve model made by any manufacturer provided it uses a
CANopen protocol and requires less than 32 bits of input and 32 bits of output data.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
How To
CONNECT a fieldbus to...
... Monitor Your Safety Controller
Fieldbus Connections
Safety Input Devices
TCP/IP
Mute Sensor
Two-Hand
Control
Rope Pull
Gate Switch
Light Curtains
Manual Reset
On/Off Switch
• Replace multiple safety modules with a single controller
Significantly reduce complexity of safety logic configuration and documentation with PC Interface
•
Minimize installation and configuration time with Controller’s Onboard
interface screen
EDM
Enabling
Device
• Support up to 22 input safety or non-safety devices:
• E-Stops
• Interlock Switches
• Safety Light Screens
• Two-Hand Controls
• Safety Mats and Edges
• Rope Pulls
• Muting Sensors
• Enabling Devices
• Bypass Switches
Features of Safety
Controller:
•
E-Stops
• Support 3 redundant safety outputs and 10 status outputs
• Monitor and manage safety related function for Category 2, 3 and 4
Use up to 10 discrete signals to monitor
the status of the safety controller
Safety Output Devices
SC22-3 Safety Controller
Encoders
BL ident (RFID)
Sensors
Solenoids
Motor Starters
Input/Output Devices
BL20 I/O System
• Accommodate any combination of input and output devices
• Available I/O modules include:
• Digital Input/Output
• Analog Input/Output
• Relay
• Temperature
• RS232/RS485
• Motor starter
• RFID
• Tension clamp or screw terminal wiring option
• Electronic modules can be pulled and plugged for maintenance without disconnecting field-wired devices
• Support a wide variety of fieldbuses including:
• DeviceNet
• EtherNet/IP
• PROFIBUS -DP
• Modbus TCP/IP
• CANopen
• PROFINET
Great Flexibility and Ease of Use
Specifications
The SC22-3 Safety Controller’s flexibility allows the user to
configure and troubleshoot with ease. The combination of high
functionality with an easy-to-use interface is right on target.
EASY
SAFETY
MODULE
LOW
FUNCTIONALITY
HIGH
FUNCTIONALITY
SC22-3
SAFETY
PLC
• Built-in programmable controller allows for small machine control or distributed system control
Power
24 VDC
400 mA
Housing
35 mm DIN Mount
Inputs
22 (Safety or Non-Safety inputs)
Safety Outputs
3 independent, Dual Channel
750 mA each @ 24 VDC (per output)
Status Outputs
10 Single Channel PNP outputs (Non-Safety)
Performance
Standards
SIL 3 per IEC 62061 and IEC 61508
Category 4 (PL e) per ISO 13849-1
Approvals
UL, CSA and CE (pending)
COMPLEX
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
Banner Engineering Corp. 9714 Tenth Ave. N. Minneapolis, MN 55441 Phone: (763) 544-3164 www.bannerengineering.com
How To
CONNECT BL67 TO WIRELESS NETWORKS...
... With DX80 Wireless Gateways
Fieldbus Connections
Process
TCP/IP
1
2
1RS485/422
Serial Connection
to Wireless
Gateway with
Modbus RTU
Master Program
Factory Automation
Agriculture & Water
Commercial &
Consumer Monitoring
3
Traffic Management
Features of SureCross Wireless System
• 900 MHz and 2.4 GHz operational frequency
Encoders
BL ident (RFID)
Sensors
Solenoids
Input/Output Devices
BL67 I/O System
• Rugged IP 67 construction allows for mounting directly on a machine without the use of an enclosure
• Support of Profibus, DeviceNet, CANopen, EtherNet/IP, Modbus TCP/IP, and Profinet
• Modular design allows for various I/O connections: up to 32 electronic modules, 256 digital or 64 analog
• System diagnostic and per point diagnostic
• Support current and voltage I/O, RTDs, thermocouples, CAN Valve interface, RS232, RS422/485 and serial synchronous interfaces
• Fast and easy connectorization using 7/8-16 UN minifast ®, M12 eurofast ®, M8 picofast ® or M23 multifast ®
• Configuration using free I/Oassistant software or rotary switches
• Reliable and secure frequency hopping spread
spectrum technology
• Robust monitoring and control capability of
hard-to-reach areas
• Per point status information in addition to systems
health-check, node operational status and signal integrity
• Easy plug-and-play deployment
• FlexPower™ System provides power management flexibility
• Integrated I/O of various configurations on board
• Configuration of SureCross wireless network via push buttons and LCD display at remote nodes
• Variety of kits available to accommodate virtually any
system integration
• Rugged IP 67 / NEMA 6 design
Possible Wireless Combinations
Manufacturer
Wireless Gateway
I/O Slice (1)
Base (2)
Cordset (3)
Banner Engineering
DX80 Series
BL67-1RS485
BL67-B-1M23-VI
CSWM 12 RKC 572-*M/BWG
Banner Engineering
DX80 Series
BL20-1RS485
BL20-S4S-SBBS
RK 4.5T-*
* Indicates length in meters.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
Banner Engineering Corp. 9714 Tenth Ave. N. Minneapolis, MN 55441 Phone: (763) 544-3164 www.bannerengineering.com
How To
CONNECT Bl ident rfid ...
... To Any PLC
PLC Processor
16 Digital 16 Digital
OUT
IN
Existing Control System
RS232
Serial
BL ident System
• 13.56 Mhz operation
Use Discrete Bits for
Communication
• ISO-15693 compliant system
• IP 20 and IP 67 RFID systems
• Up to 8 channels of RFID available per node
BL ident Applications
• 50 meters between station and read/write head
• Assembly line: record which steps have occurred and what the result was directly to
the tag
• Sortation and distribution systems: no need for database connection if destination is written to tag at induction
BL ident Read/Write Heads
• Cylindrical heads in M18 and
M30 housings
• Rectangular heads with 40 mm and
80 mm square housings
• Long range sensors for larger
conveyors available with up to
500 mm sensing range
BL ident Tags
• Flexible assembly lines: for custom build operations the required BOM could be stored into the tag and read out at each station
2RFID-A
1RS232
• Replace existing barcode system: barcode is reapplied due to paint or heat treatment where RFID can survive
• Read/write times up to 2000 bytes/sec possible
with FRAM Technology
• Standard tags include 128 byte EEPROM and 2 kbyte FRAM tags
• Available in high temperature packages, capable of up to 210°C
• Variety of tags available: bolts, ID-cards, adhesive labels, autoclave, laundry, FDA approved
• Read/write heads hot swappable
• Turn read/write heads on and
off within the program to prevent interference
• Data storage for 10 years at ambient temperatures
Possible BL ident Combinations
Use RS232 Communication
Communication
Programmable
Gateway
RFID Slice
Base
Cordset
1st I/O Slice
Base
Cordset
2nd I/O Slice
Base
Cordset
Discrete
BL67-PG-EN
BL67-2RFID-A
BL67-B-2M12
RK 4.5T-*-RS
4.5T/S2501
BL67-8DI-P
BL67-B-1M23
CSSM 12-12-*
/S817
BL67-16DO0.1A-P
BL67-B1M23-19
CSSM 1919-*
RS232 without
Handshaking
BL67-PG-EN
BL67-2RFID-A
BL67-B-2M12
RK 4.5T-*-RS
4.5T/S2501
BL67-1RS232
BL67-B-1M12
RSC 4.5T-*-DB9F/
RS232
RS232 with
Handshaking
BL67-PG-EN
BL67-2RFID-A
BL67-B-2M13
RK 4.5T-*-RS
4.5T/S2501
BL67-1RS232
BL67-B-1M12-8
RSC 8T-*-DB9F/
RS232
Discrete
BL20-PG-EN
BL20-2RFID-A
BL20-S4T-SBBS
RK 4.5T-*
/S2501
BL20-E-16DI24VDC-P
N/A
N/A
BL20-E-16DO24VDC-0.5A-P
N/A
N/A
RS232 with(out)
Handshaking
BL20-PG-EN
BL20-2RFID-A
BL20-S4S-SBBS
RK 4.5T-*
/S2501
BL20-1RS232
BL20-S4S-SBBS
DB9F-*-/RS232
* Indicates length in meters.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
How To
CREATE A Control system...
...Without a Panel
Using multiple programmable gateways in
a system provides many benefits, including
peer-to-peer communication over Ethernet. The gateways may also communicate with
an upper level system for reporting purposes
or for database connections utilizing OPC
communication.
A small button podium may be
used to house items that must
be enclosed in the panel.
BL remote is a feature available on some gateway
products that allows bridging device level networks
to Ethernet. In the example shown here, it is used
to expand the functionality of the programmable
gateway by allowing networked devices to be
used. Here we show discrete I/O and RFID being
used over BL remote; however, other signals may
be used, including analog, serial and thermocouple.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
Description
Part Number
IP 67 4A Power Supply
PSU67-11-2440/M
BL67 Ethernet Programmable Gateway
with BL remote
BL67-PG-EN-DN
BL67 RS232 Module to control display
BL67-1RS232 with BL67-B-1M12
BL67 Discrete Input Card
BL67-8DI-P with BL67-B-8M8
BL67 Analog Input Card
BL67-2AI-I with BL67-B-2M12
BL67 Discrete Output Cards
BL67-16DO-0.1A-P with BL67-B-1M23-19
BL67 to Air Pressure Sensor Cordset
RK 4.4T-*-RS 4.4T/S1119
Air Pressure Sensor
PS010V-503-LI2UPN8X-H1141
BL compact Input/Output Station
BLCDN-4M12S-8XSG-PD
30mm Barrel Inductive Proximity Switches
Bi10U-M30-AP6X-H1141
BL compact RFID Station
BLCDN-2M12S-2RFID-S
BL ident Cordset
RK 4.5T-*-RS 4.5T/S2501
BL ident CK40 RFID Transceiver
TN-CK40-H1147
BL ident 50mm Standard Tag
TW-R50-B128
*Indicates length in meters.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
How To
CONNECT Bl67 ...
®
... To PresencePLUS Vision Systems
Fieldbus Connections
Machine vision
TCP/IP
color vision
Bar code vision
®
Features of PresencePLUS Systems:
•
All Presence PLUS vision sensors include built-in serial, EtherNet/IP and Modbus TCP/IP drivers with 4 (P4) or 6 (PROII) programmable I/O. A Presence PLUS sensor, with the TURCK BL67 delivers expanded I/O, DeviceNet, PROFIBUS or PROFINET connectivity
• General-purpose or dedicated-function vision sensors
• Gray scale pattern and color spectrum analysis
Encoders
BL 67 I/O System
BL ident (RFID)
Sensors
Motor Starters
Input/Output Devices
• Rugged IP 67 construction allows for mounting directly on a machine without the use of an enclosure
• Support of Profibus, DeviceNet, CANopen, EtherNet/IP, Modbus TCP/IP, and Profinet fieldbus
• Modular design allows for various I/O connections: up to 32 electronic modules, 256 digital or 64 analog
• System diagnostic and per point diagnostic
• Support current and voltage I/O, RTDs, thermocouples, CAN Valve interface, RS232, RS422/485 and serial synchronous interfaces
Solenoids
• Fast and easy connectorization using 7/8-16 UN minifast ®, M12 eurofast ®, M8 picofast ® or M23 multifast ®
• Configuration using free I/Oassistant software or rotary switches
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
•
• Rugged IP 68-rated models suitable
for washdown applications
vision TOOLS
• Discrete I/O on-board
• Wide range of mounting brackets, lighting and lenses
• Remote TEACH functionality to
adjust image without PC
• Simple and intuitive user interface with three-step, point-and-click operation
ANALYSIS TOOLS
Two convenient form factors: one-piece
Presence PLUS P4 or compact Presence PLUS Pro sensor with a
separate DIN-mountable controller
LOCATION TOOLS
Possible Combinations
Manufacturer
Vision System
Communication
BL Gateway
I/O Slice
Base
Cordset
Banner Engineering
P4 PresencePLUS
RS232
BL67-*
BL67-1RS232
BL67-B-1M12
RS 4.5T-*-DB9M CR/RS232
Banner Engineering
P4 PresencePLUS
Ethernet
BL*-PG-EN*
N/A
N/A
N/A
* Indicates length in meters.
Banner Engineering Corp. 9714 Tenth Ave. N. Minneapolis, MN 55441 Phone: (763) 544-3164 www.bannerengineering.com
How To
connect bl Products ...
... To TURCK Analog Input Devices
Analog Sensors:
BL remote is a feature available on some gateway
products. This feature allows bridging of device
level networks to Ethernet. In this example, BL67
is operating on EtherNet/IP and drops down to the
BL compact station using BL remote.
• Pressure, temperature, sensors and transmitters for use in pneumatic and hydraulic applications
• Programmable digital read out flow sensors
• Highly reliable and precise temperature sensors
• Ultrasonic sensors
• Linear analog sensors with wide range of housing styles and output options
BL67-4AI-V/I
Sensor
LT***E-Q21R-LI***-H1151
BLC**-*M12*4AI*-VI
BL67-2AI-I & BL67-B-2M12
BL67-2AI-V & BL67-B-2M12
Current
Voltage
RKS 4.5T-*-RS 4.5T/S1121
LT***E-Q21R-LU***-H1151
LT***E-Q35R-LI***-H1151
RKS 4.5T-*-RS 4.5T/S1121
RKS 4.5T-*-RS 4.5T/S1121
LT***E-Q35R-LU***-H1151
LT***E-Q21-LI***-H1141
RKS 4.5T-*-RS 4.5T/S1121
RKS 4.5T-*-RS 4.5T/S1121
LT***E-Q21-LU***-H1141
LT***E-Q35-LI***-H1141
Level Probe Series:
• Ideal for continuous level monitoring
RKS 4.5T-*-RS 4.5T/S1121
RKS 4.5T-*-RS 4.5T/S1121
LT***E-Q35-LI***-H1141
Profile Series:
LT***E-R10-LI***-H1141
RKS 4.5T-*-RS 4.5T/S1121
RKS 4.5T-*-RS 4.5T/S1121
LT***E-R10-LU***-H1141
RKS 4.5T-*-RS 4.5T/S1121
• Uses magnetostrictive technology to monitor float location
• Low profile housing to allow
installation in tight spaces
PS***LI2UPN-H1141
• Analog output
• Stroke length up to 180 inches
PT***LI3*-H1131
• Programmable monitoring span
• Programmable zero and span points
PT***LU2*-H1131
• Stroke length up to 288 inches
• Diagnostic LED to indicate status of the sensor
FCMI-***-LI-UP8X-H1141
RK 4.4T-*-RS 4.4T/S1119
• FM approved
• Various analog output, quadrature and digital outputs give absolute position
FTCI-***-LI-UP8X-H1141
RK 4.4T-*-RS 4.4T/S1119
FCI-***LIX-H1141
RK 4.4T-*-RS 4.4T/S1118
• Automatic gain control
FCS-***LIX-H1141
RK 4.4T-*-RS 4.4T/S1118
FCS-***LIX-H1141/A
RK 4.4T-*-RS 4.4T/S1118
TS-***-LI***-H1141
RK 4.4T-*-RS 4.4T/S1119
• FM approved
RK 4.4T-*-RS 4.4T/S1119
PS***LUUPN***H1141
RK 4.4T-*-RS 4.4T/S1119
RK 4.4T-*-RS 4.4T/S618/S1166/BL
RK 4.4T-*-RS 4.4T/S618/S1165/BL
TS-***-LU***-H1141
Rod Style Series:
• Rugged rod style housing to allow operation
in high shock and vibration environments
• Hydraulic cylinder applications where rod can withstand up to 5000 PSI continuously
• Various analog output options
• 16-bit resolution
• Stroke length up to 168 inches
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
RK 4.4T-*-RS 4.4T/S1119
TT-***-LI6-H1141
RK 4.4T-*-RS 4.4T/S1119
RU***-LIX-H1141
RK 4.4T-*-RS 4.4T/S1118
RU***-LUX-H1141
RK 4.4T-*-RS 4.4T/S1118
Bi(Ni)***-LIU-H1141
RK 4.4T-*-RS 4.4T/S1119
RK 4.4T-*-RS 4.4T/S1118
WIM***-LIU-H1141
RK 4.4T-*-RS 4.4T/S1119
RK 4.4T-*-RS 4.4T/S1118
Bi(Ni)***-SIU-H1141
RK 4.4T-*-RS 4.4T/S1119
RK 4.4T-*-RS 4.4T/S1118
Bi***-LI2-H1141
RK 4.4T-*-RS 4.4T/S1119
Bi***-LU-H1341
RK 4.4T-*-RS 4.4T/S1118
Bi***-LIU-V1141
PKG 4M-*-RS 4.4T/S1117
PKG 4M-*-RS 4.4T/S1116
WIM**LIU-V1141
PKG 4M-*-RS 4.4T/S1117
PKG 4M-*-RS 4.4T/S1116
T8.3651.2544.1411
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
RK 4.5T-*-RS 4.4T/S3055
How To
connect bl67 ...
... To Sendix Encoders
Mechanical
Drive
Safety-Lock™
High Rotational
Speed
Temperature
High IP
High Shaft
Load Capacity
Reverse Polarity
Shock/Vibration
Resistance
Magnetic
Field Proof
Short-Circuit
Proof
SIN/COS
AMUSEMENT
Features of Sendix Absolute Encoders:
Hoist and hoist
control systems
for stage rigging
systems move lights,
sets and people
using gear motors,
brakes and winches.
• Singleturn and multiturn with hollow or solid shaft
• SSI communication interface
• Bus interface to CANopen and Profibus-DP
• Rugged IP 67 rating
• Highly resistant to magnetic interference
Via High Speed Counter
• Extremely fast (up to 12,000 RPM) and precise (up to 29 bit resolution)
PACKAGING
• No additional programming tools required;
Comes fully configured
Machine groups
product into case
quantities and applies
shrinkfilm. Encoder
tracks length of
product ensuring the
bar carrying film does
not touch product.
• Easy setup: LED diagnostic, M12, M23, connectivity, SET and DIR Inputs
Features of Sendix Incremental Encoders:
• Optical technology
cable management
• Solid and hollow shaft models
Encoder tracks
rotations of a drum
used to store cable.
• Differential and single-ended modes of operation
• High noise immunity and precision
• Extremely fast (up to 12,000 RPM)
Via SSI
Features of BL remote
Compatible Encoders:
Via BL remote
• Solid and hollow shaft models
• Fast (up to 6,000 RPM)
• Standard M12 connectors with bus in and bus out
Gateway
Encoder
BL*-EN-*-DN
T8.5860 (Solid Shaft)
T8.9080 (Hollow Shaft)
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
• Standard M12 and M23 connection
Slice
Base
Cordset
BL67-1SSI
BL67-B-1M12-8
E-RKC 8T-264-*-RSS 8T
BL67-1SSI
BL67-B-1M23
E-CKM CKS 12-6901-*A
BL20-1SSI
BL20-S4*-SBBS
E-RKC 8T-264-*
E-CKS 12-6901-*A
BL67-1CNT
BL67-B-1M12-8
E-RKC 8T-264-*-RSS 8T
BL67-1CNT
BL67-B-1M23
E-RKS 8T-264-*-CSM12/S3056
BL20-1CNT
BL20-S4*-SBBS
E-RKC 8T-930-*/S1115
Encoder
T8.5853
T8.5873
T8.5863
T8.5883
automotive
T8.24**
T8.36**
T8.37**
T8.50**
T8.5800-5825
T8.A02*
T8.Li20
T8.Li50
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
A shaft encoder
is mounted to the
drive rollers of a
dynamometer to
provide velocity
feedback.
USA
MEXICO
TURCK MEXICO S. DE R.L. DE C.V.
Carr. Saltillo-Zacatecas km 4.5 s/n
Parque Industrial “La Angostura”
Saltillo, COAH. C.P. 25070
Mexico
Phone:+52 (844) 411-6650/46
Fax: +52 (844) 482-6926
Local Toll Free: 01-800-01-88725
E-mail:[email protected]
CANADA
CHARTWELL ELECTRONICS, INC.
140 Duffield Drive
Markham, Ontario
Canada, L6G 1B5
Phone:(905) 513-7100
Fax: (905) 513-7101
Toll Free: 1-877-513-7769
AUSTRALIA
TURCK Australia Pty. Ltd.
Unit 5, 6-7 Gilda Court
Mulgrave, Victoria 3170
Australia
Phone:(+61) 3 9560 9006
Fax: (+61) 3 9560 1620
Local Toll Free: 1300 132566
E-mail:[email protected]
GERMANY
WORLD HEADQUARTERS
Hans TURCK GmbH & Co. KG
Witzlebenstrasse 7
D-45472 Muelheim an der Ruhr
Federal Republic of Germany
Phone:(+49) 208-49 52-0
Fax: (+49) 208-49 52 264
Printed in USA
©2008 by TURCK Inc. All rights reserved. No part of the
publication may be reproduced without written permission.
www.turck.us
TURCK Inc.
3000 Campus Drive
Minneapolis, MN 55441
Phone:(763) 553-7300
Fax: (763) 553-0708
Application Support:
1-800-544-7769
E-mail:[email protected]
www.turck.us
B3106 12/08
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement