24p2880
®
xSeries 342
Installation Guide
Install options:
• Drives
• Microprocessors
• Adapters
• Memory
Install the server in
the rack, if required
Cable the server
and options
Welcome. . .
Thank you for buying an
IBM xSeries server.
This server Installation Guide
contains information for setting
up and configuring your server.
Start the server
Did the server
start correctly?
No
Yes
For detailed information
about your server, view the
User's Reference on the
Documentation CD.
You can also find the most
current information about your
server on the IBM Web site at:
http://www.ibm.com/pc/support
Use ServerGuide™
to setup and
configure hardware
Did configuration
complete?
Go to the Server Support
flow chart
No
Yes
Use
ServerGuide to
install operating
system?
Yes
Use ServerGuide to
install applications,
such as IBM systems
management software
and IBM ServeRAID
programs
System is ready to use.
Go to the Server Support
flow chart to register
and profile your server.
No
Go to the Web for Instructions,
http://www.ibm.com/pc/support
Server Support
Server working
properly?
Yes
Register and profile your server
After you register and profile, you will be able to:
• Diagnose problems using the IBM Online Assistant
• Participate in the IBM discussion forum
• Receive e-mail notifications of technical updates
related to your profiled products
No
Check all cables for loose connections
and verify that all optional devices you
®
installed are on the ServerProven list.
You can view the ServerProven list at:
Register at: http://www.ibm.com/pc/register
Profile at: http://www.ibm.com/pc/support
http://www.ibm.com/pc/compat
Problem
solved?
Yes
No
You can view the HelpCenter phone
numbers in the Support Phone List at:
http://www.ibm.com/pc/support
Use the troubleshooting
information provided with
your server to determine
the cause of the problem
and the action to take.
Problem
solved?
Yes
No
Flash the latest levels of BIOS,
service processor, diagnostics,
and RAID code.
You can download this code at:
http://www.ibm.com/pc/support
Yes
Problem
solved?
No
Phone an
IBM HelpCenter
IBM xSeries 342
Installation Guide
IBM
Note:
Before using this information and the product it supports, be sure to read the general information in Appendix A, “Product
warranties and notices,” on page 41.
First Edition (June 2001)
© Copyright International Business Machines Corporation 2001. All rights reserved.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with
IBM Corp.
Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications and features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notices and statements used in this book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Handling static-sensitive devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Major components of the xSeries 342 server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
2
3
3
4
Chapter 2. Installing options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Working inside a server with power on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Removing the cover and bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Working with adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Adapter considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing an adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installing a hot-swap drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing a microprocessor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing a hot-swap power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing memory modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Cabling the server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
© Copyright IBM Corp. 2001
Chapter 3. Server power, controls, and indicators . . . . . . . . . . . . . . . . . . . . . . .
Turning on the server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Turning off the server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controls and indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operator information panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
21
22
23
24
Chapter 4. Configuring your server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Starting the utility programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Configuration/Setup Utility program . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the SCSISelect utility program (some models). . . . . . . . . . . . . . . . . . . . . .
Using the PXE boot agent utility program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the ServerGuide CDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the System Updates and Applications CD . . . . . . . . . . . . . . . . . . . . . . . . .
27
27
27
28
28
29
30
Chapter 5. Solving Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostic tools overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POST beep code descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POST error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ServerGuide startup problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
31
32
33
34
35
Appendix A. Product warranties and notices . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IBM Statement of Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Edition notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Processing date data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electronic emission notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Federal Communications Commission (FCC) Statement. . . . . . . . . . . . . . . . . . .
Industry Canada Class A emission compliance statement. . . . . . . . . . . . . . . . . .
Australia and New Zealand Class A statement . . . . . . . . . . . . . . . . . . . . . . . . . .
41
41
41
41
49
50
50
50
51
51
51
51
52
iii
United Kingdom telecommunications safety requirement . . . . . . . . . . . . . . . . . .
European Union EMC Directive conformance statement. . . . . . . . . . . . . . . . . . .
Taiwan electrical emission statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Japanese Voluntary Control Council for Interference (VCCI) statement . . . . . . .
Power cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
52
52
52
52
53
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
iv
IBM xSeries 342: Installation Guide
Safety
Before installing this product, read the Safety Information.
Antes de instalar este produto, leia as Informações de Segurança.
Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí.
Læs sikkerhedsforskrifterne, før du installerer dette produkt.
Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
Avant d'installer ce produit, lisez les consignes de sécurité.
Vor der Installation dieses Produkts die Sicherheitshinweise lesen.
Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.
Antes de instalar este produto, leia as Informações sobre Segurança.
© Copyright IBM Corp. 2001
v
Antes de instalar este producto lea la información de seguridad.
Läs säkerhetsinformationen innan du installerar den här produkten.
vi
IBM xSeries 342: Installation Guide
Statement 1
Danger
Electrical current from power, telephone, and communication cables is
hazardous.
To avoid a shock hazard:
•
Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical storm.
•
Connect all power cords to a properly wired and grounded electrical
outlet.
•
Connect to properly wired outlets any equipment that will be attached to
this product.
•
When possible, use one hand only to connect or disconnect signal cables.
•
Never turn on any equipment when there is evidence of fire, water, or
structural damage.
•
Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
•
Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached devices.
To connect:
To disconnect:
1. Turn everything OFF.
1. Turn everything OFF.
2. First, attach all cables to devices.
2. First, remove power cords from
outlets.
3. Attach signal cables to connectors.
4. Attach power cords to outlets.
5. Turn device ON.
3. Remove signal cables from
connectors.
4. Remove all cables from devices.
vii
Statement 2
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system
has a module containing a lithium battery, replace it only with the same
module type made by the same manufacturer. The battery contains lithium
and can explode if not properly used, handled, or disposed of.
Do not:
•
Throw or immerse into water.
•
Heat to more than 100 C (212 F)
•
Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
Statement 3
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or
transmitters) are installed, note the following:
•
Do not remove the covers. Removing the covers of the laser product
could result in exposure to hazardous laser radiation. There are no
serviceable parts inside the device.
•
Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
Danger
Some laser products contain an embedded Class 3A or Class 3B laser diode. Note
the following. Laser radiation when open. Do not stare into the beam, do not view
directly with optical instruments, and avoid direct exposure to the beam.
Class 1 Laser Product
Laser Klasse 1
Laser Klass 1
Luokan 1 Laserlaite
Appareil A` Laser de Classe 1
viii
IBM xSeries 342: Installation Guide
Statement 4
≥18 kg (39.7 lbs)
≥32 kg (70.5 lbs)
≥55 kg (121.2 lbs)
CAUTION:
Use safe practices when lifting.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
ix
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact a
service technician.
x
IBM xSeries 342: Installation Guide
Chapter 1.
Introduction
Thank you for purchasing an IBM®
Guide provides the information needed to:
xSeries 342 server. This Installation
•
Set up and cable your server
•
Start and configure your server
•
Install your network operating system (NOS)
Packaged with the Installation Guide are software CDs that help you configure
hardware, install device drivers, and install the network operating system (NOS).
Also included is an IBM xSeries Documentation CD that provides detailed information
about your server.
Your server comes with a three-year limited warranty and 90-Day IBM Start Up
Support. If you have access to the World Wide Web, you can obtain up-to-date
information about your server model and other IBM server products at the following
World Wide Web address:
http://www.ibm.com/eserver/xseries/
Record your product information in this table.
© Copyright IBM Corp. 2001
Product name
_____________________________________________
Machine type
_____________________________________________
Model number
_____________________________________________
Serial number
_____________________________________________
1
Specifications and features
The following table provides a summary of the features and specifications for your
xSeries 342 server.
Size (rack model 3U):
Environment:
•
Intel® Pentium® III
•
Height: 128 mm (5 in.)
•
•
256 or 512 KB Level-2 cache
•
Depth: 695 mm (27.3 in.)
•
Supports up to two
microprocessors
•
Width: 440 mm (17.3 in.)
•
Weight: 21.3 to 29.5 Kg (47 to 65
lb) depending upon configuration
Microprocessor:
Memory:
•
Maximum: 4 GB
Integrated functions:
•
Type: ECC, SDRAM, PC133,
registered DIMMs
•
Dual channel Ultra160 SCSI
controller
•
Four slots (two-way interleaved)
•
One 10BASE-T, 100BASE-TX,
100BASE-FX, Intel Ethernet
controller with Alert on LAN™ and
Wake on LAN® support
Drives standard:
•
Diskette: 1.44 MB
•
CD-ROM: 24X IDE
Expansion bays:
•
Hot-swap: Three slim high
•
Non-hot-swap: Two 5.25-inch,
replaceable with a three slim-high
hot-swap drive expansion option
One 33 MHz/32-bit
•
Two 33 MHz/64-bit
•
Two 66 MHz/64-bit
270 Watt (115-230 V ac)
•
Minimum: One
•
Maximum: Two - the second power
supply provides redundant power
Video:
S3 video controller
•
Compatible with SVGA and VGA
•
8 MB video memory
—
Server on: 10° to 32° C
(50° to 89.6° F). Altitude:
914 m (2998 ft) to 2133 m
(6998 ft)
—
Server off: 10° to 43° C
(50° to 109.4° F).
Maximum altitude: 2133 m
(6998 ft)
Humidity:
—
Server on: 8% to 80%
•
Two Universal Serial Bus ports
—
Server off: 8% to 80%
•
Keyboard port
•
Mouse port
•
Video port
Approximate heat output in British
thermal units (Btu) per hour
•
Integrated System Management
(ISM) Processor
•
Minimum configuration: 375 Btu
(110 watts)
—
Two ISM (RJ-45) connectors
•
—
One system management
Serial C port
Maximum configuration: 1300
Btu (380 watts)
•
Sound power, idling (open bay):
6.6 bel maximum
•
Sound power, operating: 6.8 bel
maximum
•
Sound pressure, operating: 53
dBa maximum
Heat output:
Electrical input:
•
Sine-wave input (50-60 Hz)
required
•
Input voltage low range:
•
Redundant cooling:
•
Server on: 10° to 35° C
(50° to 95° F). Altitude: 0 to
914 m (2998 ft)
Two serial ports
Acoustical noise emissions:
Hot-swap power supplies:
—
•
PCI expansion slots:
•
•
Air temperature:
Three hot-swap fans
•
—
Minimum: 100 V ac
—
Maximum: 127 V ac
Input voltage high range:
—
Minimum: 200 V ac
—
Maximum: 240 V ac
Input kilovolt-amperes (kVA)
approximately:
—
Minimum: 0.08 kVA (0.076
kW)
Table 1. Features and Specifications.
*KB equals approximately 1000 bytes. MB equals approximately 1000000 bytes. GB
equals approximately 1000000000 bytes.
2
IBM xSeries 342: Installation Guide
Notices and statements used in this book
The caution and danger statements also appear in the multilingual Safety Information
book, provided on the IBM xSeries Documentation CD, that comes with your xSeries
product. Each statement is numbered for easy reference to the corresponding
statements in the safety book.
The following types of notices and statements are used in this book:
•
Note: These notices provide important tips, guidance, or advice.
•
Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
•
Attention: These notices indicate possible damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage could occur.
•
Caution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
•
Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation.
Handling static-sensitive devices
Attention: Static electricity can damage electronic devices and your system. To
avoid damage, keep static-sensitive devices in their static-protective packages until
you are ready to install them.
To reduce the possibility of electrostatic discharge, observe the following precautions:
•
Limit your movement. Movement can cause static electricity to build up around
you.
•
Handle the device carefully, holding it by its edges or its frame.
•
Do not touch solder joints, pins, or exposed printed circuitry.
•
Do not leave the device where others can handle and possibly damage the
device.
•
While the device is still in its anti-static package, touch it to an unpainted metal
part of the system unit for at least two seconds. (This drains static electricity from
the package and from your body.)
•
Remove the device from its package and install it directly into your system unit
without setting it down. If it is necessary to set the device down, place it in its
static-protective package. Do not place the device on your system unit cover or
on a metal table.
•
Take additional care when handling devices during cold weather; heating reduces
indoor humidity and increases static electricity.
Chapter 1. Introduction
3
Major components of the xSeries 342 server
weiv de olpxThe
E
orange color on components and labels in your server identifies hot-swap
components. You can install or remove hot-swap components while the system is
running, provided that your system is configured to support this function. For complete
information about installing or removing a hot-swap component, see the detailed
information in this chapter.
The blue color on components and labels indicates touch points where a component
can be gripped, a latch moved, and so on.
Note: The illustrations in this document might differ slightly from your hardware.
Hot-swap fan
Air baffle
Memory module
Fan sink
Microprocessor
Filler panel for
drive bay
Terminator card
System board
Hot-swap hard
disk drive
Hot-swap
power supply
Filler panel for device bay
Filler panel for
power supply bay
4
IBM xSeries 342: Installation Guide
Chapter 2.
Installing options
This chapter provides the basic information needed to install hardware options in your
server. This section is for all users, but is written with the experienced user in mind. If
you need more detailed installation information for options such as tape drives or the
3-pack hard disk drive expansion kits, refer to the User’s Reference on the IBM
xSeries Documentation CD.
Working inside a server with power on
Your server supports hot-swap drives, fans, and power supplies and is designed to
operate safely while turned on with the cover removed. Follow these guidelines when
you work inside a server that is turned on.
© Copyright IBM Corp. 2001
•
Avoid loose-fitting clothing on your forearms. Button long-sleeved shirts before
working inside the server; do not wear cuff links while you are working inside the
server.
•
Do not allow your necktie or scarf to hang inside the server.
•
Remove jewelry, such as bracelets, rings, necklaces, and loose-fitting wrist
watches.
•
Remove items from your shirt pocket (such as pens or pencils) that could fall into
the server as you lean over it.
•
Do not allow the cover on the server to remain off. Operating the server for
extended periods of time (over 30 minutes) with the cover removed might cause
damage to server components.
•
Take care to avoid dropping any metallic objects, such as paper clips, hair pins, or
screws, into the server.
5
Removing the cover and bezel
l ezeb dna revoc eht gn i vomeRefer
R
to the following illustration to remove the cover and bezel.
Note: The illustrations in this document might differ slightly from your hardware.
Cover-release latch
Side latch
Bezel
Side latch
To remove the server top cover:
1. If you are planning to install or remove any part other than a hot-swap hard disk
drive, hot-swap power supply, or hot-swap fan, turn off the server and all attached
devices and disconnect all external cables and power cords.
2. Lift the cover-release latch. Lift the cover off the server and set the cover aside.
Attention: For proper cooling and airflow, replace the cover before turning on the
server. Operating the server for extended periods of time (over 30 minutes) with
the cover removed might damage server components.
To remove the bezel:
1. Press in on the top sides of the bezel, and rotate the bezel away from the server
front.
2. Store the bezel in a safe place.
6
IBM xSeries 342: Installation Guide
Working with adapters
sretpada ht iw gni kroYou
W
can install up to five peripheral component interconnect (PCI) adapters in the
expansion connectors, called slots, on the system board.
Your server comes with an integrated video controller, which is not removable. When
you install a video adapter, the server BIOS (basic input/output system) code
automatically disables the integrated video controller.
The following illustration shows the location of the PCI expansion slots on the system
board.
Note: The illustrations in this document might differ slightly from your hardware.
PCI Slot 1
32-bit
33 MHz (J44)
PCI Slot 2
64-bit
33 MHz (J41)
PCI Slot 3
64-bit
33 MHZ (J42)
PCI Slot 4
64-bit
66 MHz (J29)
PCI Slot 5
64-bit
66 MHz (J30)
Adapter considerations
Before you install adapters, review the following:
•
Locate the documentation that comes with the adapter and follow those instructions in addition to the instructions given in this chapter. If you need to change the
switch or jumper settings on your adapter, follow the instructions that come with
the adapter.
•
You can install full-length and half-length adapters in all slots.
•
Some full-length adapters with daughterboards can interfere with SCSI channel B
and should not be installed in PCI slot 1.
•
You can install a 32-bit adapter in any of the PCI slots.
•
Your server supports 5.0 V and universal PCI adapters; it supports only 3.3 V universal adapters in PCI slots 4 and 5.
•
You might require additional power supplies if adapters are added that have electrical current requirements that exceed the installed power-supply capabilities.
Chapter 2. Installing options
7
•
Your server uses a rotational interrupt technique to configure PCI adapters.
Therefore, you can install a variety of PCI adapters that currently do not support
sharing of PCI interrupts.
•
The Remote Supervisor Adapter is supported in PCI slot 1 only.
Note: The ribbon cable that ships with the adapter is required to connect the
adapter to the system board. The external power adapter that ships with
the adapter is not required with this server.
•
PCI slot 1 is on PCI bus A, PCI slots 2 and 3 are on PCI bus B, and PCI slots 4
and 5 are on PCI bus C.
Note: PCI bus A is often referred to as bus 0; PCI bus B is often referred to as
bus 1; and PCI bus C is often referred to as bus 2.
•
The system scans PCI slot 1, the system board Ethernet, PCI slots 2-5, the
system board SCSI, and then SCSI channels A and B, if you have not changed
the boot precedence from the default.
You can use the Configuration/Setup Utility program to change the boot
precedence for your server. Select Start Options from the Configuration/Setup
Utility program main menu.
Installing an adapter
Refer to the following illustration to install an adapter.
Note: The illustrations in this document might differ slightly from your hardware.
Adapter
Expansion-slot cover
To install an adapter:
1. Review the information in “Safety” on page v.
2. Turn off the server.
8
IBM xSeries 342: Installation Guide
3. Remove the cover.
4. Determine which expansion slot you will use for the adapter.
5. Remove the expansion-slot cover.
6. Place the adapter, component-side up, on a flat, static-protective surface.
7. Set any jumpers or switches as described by the adapter manufacturer.
8. Install the adapter.
9. Connect any needed cables to the adapter.
10. If you have other options to install, install them now. Otherwise, install the cover
and proceed to “Cabling the server” on page 19.
The following illustration shows the rerouting of the SCSI cable if you install a
ServeRAID™ adapter.
SCSI
connector A (J24)
Chapter 2. Installing options
9
The following illustration shows SCSI connector A, into which you plug the SCSI
cable.
SCSI A
connector
(J24)
10
IBM xSeries 342: Installation Guide
Installing a hot-swap drive
The hot-swap drive bays support hot-swap drives only. Refer to the following
illustration to install a hot-swap drive.
Note: The illustrations in this document might differ slightly from your hardware.
Drive-tray assembly
Drive handle
Filler panel
To install a drive in a hot-swap drive bay:
Attention:
•
To maintain proper system cooling, do not operate the server for more than two
minutes without either a drive or a filler panel installed for each bay.
•
When you handle static-sensitive devices, take precautions to avoid damage from
static electricity.
1. Remove the filler panel from one of the empty hot-swap bays.
2. Ensure the tray handle is open.
3. Gently push the drive-tray assembly into the bay until the drive touches the backplane.
4. Push the tray handle down until it locks.
Note: If your server has a RAID adapter installed, refer to the information provided with the RAID adapter for information about adding a drive.
5. If you have other options to install, install them now. Otherwise, install the cover
and proceed to “Cabling the server” on page 19.
Installing a microprocessor
ros ecorporcim a gni l atsnYour
I
server comes with one microprocessor installed on the system board. If you
install an additional microprocessor, your server can operate as a symmetric
multiprocessing (SMP) server. With SMP, certain operating systems and application
programs can distribute the processing load between the microprocessors.
Chapter 2. Installing options
11
Attention: To avoid damage and ensure proper server operation when you install a
new or additional microprocessor, use microprocessors that have the same cache
size and type, and the same clock speed. Microprocessor internal and external clock
frequencies must be identical.
To install an additional microprocessor:
1. Review the information in “Safety” on page v.
2. Turn off the server and peripheral devices and disconnect all external cables and
power cords; then, remove the cover.
3. Remove the fan 3 assembly.
Fan 3
Air baffle
4. Remove the air baffle.
5. Remove the terminator card from the microprocessor connector.
12
IBM xSeries 342: Installation Guide
Terminator card
VRM 2
Fan sink
(Remove thermal tape liner on installation)
Microprocessor 2
Microprocessor 1 location
VRM 1
VRM connector
6. Store the terminator card in a safe place in the static-protective package.
7. Install the microprocessor.
8. Install the voltage regulator module (VRM) included in the microprocessor kit.
Attention: When installing or replacing a VRM, use only a VRM specified for use
with the xSeries 342 server. Use of other VRMs might cause your server to
overheat.
9. Remove the clear plastic liner from the thermal material on the underside of the
fan sink and discard.
10. Set the fan sink into place.
Fan sink
(Remove thermal tape
liner on installation)
Ensure correct alignment
of fan sink, mounting clip,
and mounting socket
Chapter 2. Installing options
13
Make sure the fan sink guide fits between the processor and the processor
socket.
Spring retention clip
Fan sink guide
11. Press down and latch the spring retention clip on the back of the fan sink (the side
facing the back of the server).
12. Press down and latch the spring retention clip on the front of the fan sink (the side
facing the front of the server).
13. Plug the fan sink into the fan sink connector on the system board (J46). Make
sure the cable is not in a position to interfere with the fan sink operation.
14. Reinstall the air baffle and the fan assembly.
15. If you have other options to install, install them now. Otherwise, install the cover
and proceed to “Cabling the server” on page 19.
14
IBM xSeries 342: Installation Guide
Installing a hot-swap power supply
y lp us rewop paws- toh a gni l atsnYour
I
server comes with one 270 Watt power supply. You can install an additional
power supply. Each power supply has two status indicators; see the following
illustration for information about the status indicators and power-supply bay locations.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label
attached.
Hazardous voltage, current, and energy levels are present inside any component that
has this label attached. There are no serviceable parts inside these components. If you
suspect a problem with one of these parts, contact a service technician.
Note: The illustrations in this document might differ slightly from your hardware.
Power supply
Handle
AC power
LED (green)
DC power
LED (green)
Filler
panel
Chapter 2. Installing options
15
To install a power supply:
1. Remove the bezel from the front of the server.
2. Remove the filler panel from the empty power-supply bay.
3. Move the handle on the power supply into the open (up) position, and slide the
power supply into the chassis.
4. Push the handle down into the closed position to seat the power supply in the bay.
5. Plug the power cord for the added power supply into the power-cord connector on
the rear of the server. Then, plug the power cord into a properly grounded electrical outlet.
Power supply 1 power cord connector
Power supply 2 power cord connector
6. Verify that the dc power light and ac power light on the power supply are lit, indicating that the power supply is operating correctly.
7. Replace the front bezel.
8. If you have other options to install, install them now. Otherwise, install the cover
and proceed to “Cabling the server” on page 19.
Installing memory modules
Adding memory to your server is an easy way to make programs run faster. You can
increase the amount of memory in your server by installing options called memorymodule kits. Each kit contains one industry-standard, dual inline memory module
(DIMM). Your server uses a two-way interleaved memory configuration. You must
install matched pairs of memory kits, but the set in slots 1 and 4 do not need to be the
same size as the set in slots 2 and 3.
Notes:
1. Your server comes with two dual inline memory modules (DIMMs) installed in
DIMM slots 1 and 4. Install additional DIMMs as a matched pair in DIMM slots 2
and 3 and as instructed in the documentation that comes with your option.
2. Your xSeries 342 server supports 128 MB, 256 MB, 512 MB, and 1GB DIMMs.
You must install the DIMMs in pairs of the same size. Place pair 1 in slots 1 and 4
and pair 2 in slots 2 and 3. Refer to the ServerProven® list on the World Wide
Web at http://www.ibm.com/pc/compat for information about memory modules for
use with your server.
3. Installing or removing DIMMs changes the configuration information in the server.
Therefore, after installing or removing a DIMM, you must save the new configuration information in the Configuration/Setup Utility program. When you restart the
server, the system displays a message indicating that the memory configuration
has changed. Start the Configuration/Setup Utility program and select Save Settings.
16
IBM xSeries 342: Installation Guide
Note: The illustrations in this document might differ slightly from your hardware.
DIMM 1
DIMM 2
DIMM connector 4 (J4)
DIMM connector 3 (J3)
DIMM connector 2 (J2)
DIMM connector 1 (J1)
To install a DIMM:
1. Review the information in “Safety” on page v.
2. Turn off the server and peripheral devices and disconnect all external cables and
power cords.
3. Remove the cover.
4. Install the DIMM:
a. Carefully rotate the retaining clips away from the connector and into the open
position.
DIMM 3
DIMM 2
DIMM 4
DIMM 1
Chapter 2. Installing options
17
b. Position the DIMM so that is aligns correctly with the connector.
Note: The DIMM is "keyed" for proper insertion.
c.
Insert the DIMM into the connector by pressing one edge of the DIMM and
then the other edge of the DIMM.
d. Make sure the retaining clips are in the closed position. If a gap exists
between the DIMM and the retaining clips, the DIMM has not been properly
installed. In this case, open the retaining clips and remove the DIMM; then,
reinsert the DIMM.
e. Repeat steps 4a through 4d for the second DIMM; then continue with step 5.
5. Make sure the retaining clips are in the closed position.
6. If you have other options to install, install them now. Otherwise, install the cover
and proceed to “Cabling the server” on page 19.
18
IBM xSeries 342: Installation Guide
Cabling the server
Use the Rack Installation Instructions provided with your server to install the server in
a rack. Then, use the illustrations in this section to cable the server and route the
cables through the cable-management arm.
The following illustration shows external connectors and cable routing for the server.
Note: The illustrations in this document might differ slightly from your hardware.
Mouse
Serial A
Serial B
Video
Keyboard
Ethernet
ISM-A
ISM-B
Serial C
Universal Serial Bus
(USB) 1 and 2
Chapter 2. Installing options
19
20
IBM xSeries 342: Installation Guide
Chapter 3.
Server power, controls, and indicators
This chapter includes the instructions needed to turn on and turn off the server and
information about the server controls and indicators.
Turning on the server
revres eht gni t ratAfter
S
you plug the power cord of your server into the power supply and an electrical
outlet, you can start the server in several ways:
© Copyright IBM Corp. 2001
•
You can turn on the server by pressing the power-control button on the front of the
server.
•
If the server is turned on, a power failure occurs, and unattended-start mode is
enabled in the Configuration/Setup utility program, the server will start
automatically when power is restored.
•
If ac power is present, the server is off, and the wake-up feature is enabled in the
Configuration/Setup utility program, the wake-up feature will turn on the server at
the set time.
•
The Integrated System Management Processor can also turn on the server.
•
If ac power is present, the system is off and the Wake on LAN feature is enabled,
the system can be turned on by a network wake-up from the onboard Intel
Ethernet controller.
21
Turning off the server
Statement 5
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
You can turn off the server in any of the following ways:
•
You can press the power-control button on the front of the server. This starts an
orderly shutdown of the operating system, if this feature is supported by your
operating system.
Note: After turning off the server, wait at least 5 seconds before you press the
power-control button to turn on the server again.
•
You might need to press and hold the power-control button for more than 4
seconds to cause an immediate shutdown of the server and to force the power
off. You can use this feature if the operating system stops functioning.
•
You can disconnect the server power cords from the electrical outlets to shut off
all power to the server.
Note: After disconnecting the power cords, wait approximately 15 seconds for
your system to stop running. Watch for the power-on light to stop blinking.
22
•
If the system was turned on by the wake-up feature or Wake on LAN feature, you
can turn it off by either a software runtime or by the fail-safe, power-down counter.
•
The Integrated System Management Processor can turn off the server.
IBM xSeries 342: Installation Guide
Controls and indicators
srotaci dni dna slor tnoThe
C
following illustration shows the controls and indicators on the front of your server.
Note: The illustrations in this document might differ slightly from your hardware.
System power light (green)
Power-control-button shield (if installed)
Power control button
Reset button
Operator information panel
Serial number
Hard disk drive activity light (green)
Hard disk drive status light (amber)
System power light: When this green light is on, system power is present in the
server. When this light flashes, the server is in standby mode (the system power
supply is turned off and ac current is present). When this light is off, either a power
supply, ac power, or a light has failed.
Attention: If this light is off, it does not mean there is no electrical current present in
the server. The light might be burned out. To remove all electrical current from the
server, you must unplug the server power cords from the electrical outlets or from the
UPS.
Power-control button shield: You can install this circular disk over the powercontrol button to prevent accidental manual power-off. This disk is provided with your
server.
Power-control button: Press this button to manually turn the server on or off.
Reset button: Press this button to reset the server and run the power-on self-test
(POST). You might need to use a pen or the end of a straightened paper clip to press
this button.
Operator information panel: The lights on this panel give status information for your
server. See “Operator information panel” on page 24 for more information.
Hard disk drive status light: Each of the hot-swap drives has a hard disk drive
status light. When this amber light is on continuously, the drive has failed.
If a ServeRAID adapter is installed and this light flashes slowly (one flash per
second), the drive is being rebuilt. When the light flashes rapidly (three flashes per
second), the controller is identifying the drive.
Hard disk drive activity drive light: Each of the hot-swap drives has a hard disk
drive activity light. When this green light is flashing, the controller is accessing the
drive.
Chapter 3. Server power, controls, and indicators
23
AC power
LED (green)
DC power
LED (green)
AC power light: This green light on the power supply (behind the bezel) provides
status information about the power supply. During normal operation, both the ac and
dc power lights are on.
DC power light: This green light on the power supply (behind the bezel) provides
status information about the power supply. During normal operation, both the ac and
dc power lights are on.
Operator information panel
lenap noi tamrofni rotarepThe
O
following illustration shows the lights on the operator information panel on the
front of the server. (See “Controls and indicators” on page 23 for the location of the
operator information panel.)
Note: The illustrations in this document might differ slightly from your hardware.
SCSI Hard
Drive Activity
Light (green)
Ethernet Link
Status Light
(green)
TX
RX
Ethernet
Transmit/
Receive
Activity Light
(green)
LINK
OK
Information
Light (amber)
System
Error
Light (amber)
SCSI hard disk drive activity light: This green light is on when there is activity on a
hard disk drive.
Ethernet transmit/receive activity light: When this green light is on, there is
transmit or receive activity to or from the server. This light stays on even if the server
power is turned off.
24
IBM xSeries 342: Installation Guide
Ethernet link status light: This green LED lights when there is an active connection
on the Ethernet port during typical operation, when the system is powered off the
LED remains green.
Information light: This amber light is on when the information log contains
information about certain conditions in your server that might affect performance.
System error light: This amber light is lit when a system error occurs. An LED on the
diagnostic LED panel will also be on to further isolate the error.
Chapter 3. Server power, controls, and indicators
25
26
IBM xSeries 342: Installation Guide
Chapter 4.
Configuring your server
You can use the following configuration programs to customize your server hardware:
•
Configuration/Setup Utility
This program is part of the basic input/output system (BIOS) code that comes with
your server. You can use this program to configure serial port assignments,
change interrupt request (IRQ) settings, change the drive startup sequence, set
the date and time, and set passwords. See “Using the Configuration/Setup Utility
program” for more information on the Configuration/Setup Utility.
•
SCSISelect Utility
With the built-in SCSISelect Utility program, you can configure the devices
attached to the integrated SCSI controller. Use this program to change the default
values. resolve configuration conflicts, and perform a low-level format on a SCSI
hard disk drive. See “Using the SCSISelect utility program (some models)” on
page 28 for more information on the SCSISelect Utility.
•
PXE Boot Agent Utility
The Preboot eXecution Environment (PXE) Boot Agent Utility program is part of
the BIOS code that comes with your server. You can use this program to change
network startup (boot) protocols and startup (boot) order, to select operating
system wake-up support, and to set menu wait times. See “Using the PXE boot
agent utility program” on page 28 for more information on the PXE Boot Agent
Utility.
•
ServerGuide CDs
The ServerGuide™ CDs include software setup and installation tools specifically
designed for IBM xSeries servers. You can use these CDs during the initial
installation of your server to configure the server hardware and simplify your
network operating system installation. The ServerGuide CDs also contain a
collection of application programs, which you can install after your server is up
and running. See “Using the ServerGuide CDs” on page 29 for more information
on the ServerGuide CDs.
•
ServeRAID programs
The ServeRAID programs come with the optional ServeRAID adapters and with
server models that have a ServeRAID adapter preinstalled. If your server has a
ServeRAID adapter installed, you must use the ServeRAID configuration program
to define and configure your disk-array subsystem before you install your
operating system. Refer to the ServeRAID documentation provided on the
xSeries Documentation CD for more information.
Starting the utility programs
This section provides the instructions for starting the utility programs. For more
detailed information about these utility programs, refer to the User’s Reference on the
IBM xSeries Documentation CD.
Using the Configuration/Setup Utility program
Configuration/Setup is a menu-driven utility that is part of the BIOS code that comes
with your server. You can use it to:
© Copyright IBM Corp. 2001
•
Configure serial connector assignments
•
Change the drive startup sequence
•
Enable USB keyboard and mouse support
27
•
Resolve configuration conflicts
•
Set the date and time
•
Set passwords
Starting the Configuration/Setup Utility program
Complete the following steps to start the Configuration/Setup Utility program:
1. Turn on the server and watch the monitor screen.
2. When the message Press F1 for Configuration/Setup appears, press F1.
3. Follow the instructions that appear on the screen.
Using the SCSISelect utility program (some models)
SCSISelect is a built-in, menu-driven configuration utility program that you can use to:
•
View the default SCSI IDs
•
Locate and correct configuration conflicts
Note: If your server has a redundant arrays of independent disks (RAID) adapter
installed, use the configuration method that is supplied with the RAID adapter
to view or change SCSI settings for devices attached to the adapter.
Starting the SCSISelect utility program
Complete the following steps to start the SCSISelect Utility program:
1. Turn on the server.
2. When the <<< Press <CTRL><A> for SCSISelect™ Utility! >>> prompt appears,
press Ctrl+A.
3. When the Would you like to configure the host adapter or run the SCSI
disk utility? question appears, make your selection and press Enter.
4. Use the arrow keys to select a choice from the menu.
•
Press Esc to exit the SCSISelect Utility program.
•
Press the F5 key to switch between color and monochrome modes (if your
monitor permits).
5. Follow the instructions on the screen to change the settings of the selected items;
then, press Enter.
Using the PXE boot agent utility program
The PXE boot agent is a built-in, menu-driven configuration utility program that you
can use to:
•
Change network startup (boot) protocols
•
Change startup (boot) order
•
Select whether or not to display setup prompt
•
Set menu wait time
•
Select OS wake up support
Starting the PXE boot agent utility program
The following sections provide the instructions needed to start the PXE Boot Agent
Utility and descriptions of the menu choices available.
To start the PXE Boot Agent Utility program:
1. Turn on the server.
28
IBM xSeries 342: Installation Guide
2. When the Initializing Intel (R) Boot Agent Version X.X.XX
PXE 2.0 Build XXX (WfM 2.0) prompt appears, press Ctrl+S.
Note: By default you will have two seconds after the prompt appears on the
screen to press Ctrl+S.
3. Use the arrow keys or press Enter to select a choice from the menu.
•
Press Esc to return to the previous menu.
•
Press the F4 key to exit.
4. Follow the instructions on the screen to change the settings of the selected items;
then, press Enter.
Using the ServerGuide CDs
The ServerGuide CDs include easy-to-use software setup and installation tools that
are specifically designed for your IBM server. The ServerGuide Setup and Installation
program detects the server model and hardware options that are installed and uses
that information during setup to configure the hardware. The ServerGuide tools
simplify NOS installations by providing updated device drivers, and in some cases,
installing them automatically.
If a newer version of the ServerGuide software is available, you can purchase an
update package. For details, see the ServerGuide Updates form that comes with your
server library, or go to the ServerGuide fulfillment Web site at
http://www.ibm.com/pc/coupon
The ServerGuide software has these features to make setup easier:
•
An easy-to-use interface with online help
•
Diskette-free setup, and configuration programs that are based on detected
hardware
•
Performance Optimizer program, which easily tunes your server for your
environment
•
A system BIOS update program, which updates the BIOS directly from the CD
•
Device drivers that are provided for your server model and detected hardware
•
NOS partition size and file-system type that are selectable during setup
•
Powerful application programs and administration tools
The ServerGuide CDs provide state-of-the-art programs to detect the server model
and hardware options that are installed, configure the server hardware, provide
device drivers, and install your network operating system (NOS).
Note: If the ServerGuide CD does not start, see “ServerGuide startup problems” on
page 34.
1. Insert the Setup and Installation CD, and restart the server.
2. Follow the instructions on the screens to:
a. Select your language.
b. Select your keyboard layout and country.
c.
View the Overview to learn about ServerGuide features.
d. View the README file to review installation tips about your NOS and adapter.
e. Start the setup and hardware configuration programs.
f.
Start the NOS installation. You will need your copy of the NOS CD.
Note: For information on the supported NOS versions, refer to the Setup and
Installation CD label.
Chapter 4. Configuring your server
29
Using the System Updates and Applications CD
Be sure to take advantage of the additional software that is provided on the System
Updates and Applications CD.
Note: See the CD label for a current list of updates and applications to start the CD
and view the online overview.
30
IBM xSeries 342: Installation Guide
Chapter 5.
Solving Problems
This chapter provides basic troubleshooting information to help you resolve some
common problems that might occur with your server.
If you cannot locate and correct the problem using the information in this section, refer
to the " Solving problems" section in the User’s Reference on the xSeries
Documentation CD and the "Server Support" flowchart in the front of this booklet for
additional information.
Diagnostic tools overview
The following tools are available to help you identify and resolve hardware-related
problems:
•
POST beep codes and error messages
The power-on self-test (POST) generates beep codes and messages to indicate
successful test completion or the detection of a problem.
•
Troubleshooting charts
These charts list problem symptoms, along with suggested steps to correct the
problems. See the “Troubleshooting chart” on page 35 for more information.
•
Error logs
The POST error log contains the three most recent error codes and messages
that the system generated during POST. The System Event/Error Log contains all
error messages issued during POST and all system status messages from the
system environmental monitor subsystem.
To view the contents of the error logs, start the Configuration/Setup Utility
program; then, select Error Logs from the main menu.
•
Diagnostic programs and error messages
The server diagnostic programs are stored in upgradable read-only memory
(ROM) on the system board. These programs are the primary method of testing
the major components of your server.
Note: Refer to the "Solving Problems" section in the User’s Reference on the
xSeries Documentation CD for more detailed information about the diagnostic programs.
© Copyright IBM Corp. 2001
31
POST beep code descriptions
POST emits one beep to signal successful completion. If POST detects a problem
during startup, other beep codes might occur. You can use the following beep code
descriptions to help identify and resolve problems that are detected during startup.
Note: Refer to the "Solving Problems" section in the User’s Reference on the
xSeries Documentation CD for more detailed information about the POST
beep codes.
Beep code
Descriptions of the POST beep codes
No beep
Call for service.
Continuous
If no video appears, the startup microprocessor failed. Verify that the startup microprocessor is
installed correctly. If it is, replace the startup microprocessor. If the problem persists, call for
service.
One short
POST completed successfully. One beep also occurs after POST if you enter an incorrect
password.
Two short
Follow the instructions that appear on the screen.
Three short
POST detected a system memory error. Verify that the memory is installed correctly. If it is,
replace the failing memory module.
Attention: In some memory configurations, the 3-3-3 beep code might sound during POST
followed by a blank display screen. If this occurs and the Boot Fail Count feature in the Start
Options of the Configuration/Setup Utility is set to Enabled (its default setting), you must restart
the server three times to force the system BIOS code to reset the memory connector or bank of
connectors from Disabled to Enabled.
Repeating short
The system board might contain a failing component.
1.
Verify that the keyboard and pointing devices are connected properly.
2.
Ensure that nothing is resting on the keyboard.
3.
Disconnect the pointing device; then, restart the server. If the problem goes away, replace
the pointing device. If the problem remains, call for service.
One long and one
short
If the video controller on the system board is being used, call for service. If you installed an
optional video adapter, replace the failing adapter
One long and two
short
A video I/O adapter ROM is not readable, or the video subsystem is defective. If you installed
an optional video adapter, replace the failing adapter. If the problem remains, call for service.
One long and three
short
The system-board video subsystem has not detected a monitor connection to the server.
Ensure that the monitor is connected to the server. If the problem persists, replace the monitor.
Two long and two
short
POST does not support the optional video adapter. Replace the optional video adapter with one
that is supported by the server or use the integrated video controller. See the ServerProven list
on the web at www.ibm.com/pc/compat.
All other beep codes
1.
Verify that the system memory modules are installed correctly.
2.
Tun off the server; then, restart the server. If the problem remains, call for service.
Table 2. POST beep code descriptions.
32
IBM xSeries 342: Installation Guide
POST error messages
The following tables provide information about the POST error messages that can
appear during POST.
Note: Refer to the User’s Reference on the IBM xSeries Documentation CD for more
detailed information about POST error messages.
POST message
Failing device or problem found
Suggested action
129
L1 cache of a microprocessor
Check the installation of your microprocessors.
161
The real-time clock battery has
failed.
Replace the battery yourself or call for service.
You can use the server until you replace the battery.
However, you must run the Configuration/Setup Utility
program and set the time and date and other custom settings
each time you turn on the server.
162
Change in device configuration
Verify that your optional devices are turned on and installed
correctly.
163
Time of day has not been set
Set the correct date and time.
164
Change in memory configuration
Verify that your memory is installed properly; then, restart the
server and run the Configuration/Setup Utility program.
178
A POST error occurred when the
server was rebooted or powered on.
Flash the Remote Supervisor Adapter with firmware to
configure it to the server it is installed in.
201
Change in memory configuration
Verify that your memory is fully seated and installed properly.
229
L2 cache of a microprocessor
Check the installation of your microprocessors.
289
Failing DIMM was disabled
Verify that your memory is correct for your server and that it is
installed properly.
301
Keyboard and keyboard controller
Ensure that the keyboard cable is connected and nothing is
resting on the keyboard keys.
11xx
Serial port error
Verify that the serial cable is connected correctly.
1162
Serial port configuration conflict
Start the Configuration/Setup program and ensure that the
IRQ and I/O port assignments needed by the serial port are
available.
1601
BIOS update needed
Download and install the latest system BIOS code level.
1800
PCI adapter hardware interrupt
Start the Configuration/Setup program and verify that the
interrupt resource settings are correct.
2400
Video controller and memory
Verify that the monitor is connected correctly.
00019xxx
Processor x is not functioning or
failed the built-in test
Verify that processor x is installed correctly. If the problem
remains, replace processor x.
00180xxx
A PCI adapter requested a resource
that is not available
Start the Configuration/Setup program and ensure that the
resources needed by the PCI adapter are available.
012980xx
Data for processor x
Download and install the latest system BIOS code level.
Microprocessor speed mismatch
Install microprocessors with identical speeds.
303
2462
012981xx
01298200
Table 3. Abbreviated list of POST error messages.
Chapter 5. Solving Problems
33
ServerGuide startup problems
Look for the symptom in the left column of the chart. Probable solutions to the
problem are in the right column.
Setup
Setup and Installation CD will not
start.
Suggested action
•
Ensure that the system is a supported server with a startable (bootable) CDROM drive.
•
If the startup (boot) sequence settings have been altered, be sure the CDROM is first in the boot sequence.
•
If more than one CD-ROM drive is installed, be sure that only one drive is set
as the primary drive. Start the CD from the primary drive.
ServeRAID program cannot view all
installed drives - or - cannot install
NOS.
•
Ensure that there are no duplicate SCSI IDs or IRQ assignments.
•
Ensure that the hard disk drive is connected properly.
The Operating System Installation
program continuously loops.
Free up more space on the hard disk drive.
ServerGuide will not start your NOS
CD.
Ensure that the NOS CD you have is supported by ServerGuide. See the Setup
and Installation CD label for a list of NOS versions supported.
Cannot install NOS - option is
grayed out.
Ensure that the NOS is supported on your server. If the NOS is supported, either
there is no logical drive defined (ServeRAID systems) or the ServerGuide System
Partition is not present. Run the ServerGuide setup and configuration program,
and ensure that setup is complete.
System Updates and Applications
CD
Get "time out" or "Unknown host"
errors
34
IBM xSeries 342: Installation Guide
Suggested action
Ensure that you have access to the Internet through FTP directly.
Troubleshooting chart
t rahc gni to hselbuorYou
T
can use the troubleshooting charts in this section to find solutions to problems
that have definite symptoms.
Attention: If diagnostic error messages appear that are not listed in the following
tables, make sure your server has the latest levels of BIOS code, the System
Management processor, ServerRAID, and diagnostics.
Look for the symptom in the left column of the chart. Instructions and probable
solutions to the problem are in the right column. If you have just added new software
or a new option and your server is not working, do the following before using the
troubleshooting charts:
•
Remove the software or device that you just added.
•
Run the diagnostic tests to determine if your server is running correctly.
•
Reinstall the new software or new device.
Notes:
1. Refer to the "Solving problems" section of the User’s Reference on the IBM
xSeries Documentation CD for more detailed troubleshooting charts.
2. If you cannot find the problem in the troubleshooting charts, run the diagnostic
programs. If you have run the diagnostic test programs, or if running the tests
does not reveal the problem, call for service.
Device
CD-ROM drive
CD-ROM drive is not
recognized.
Suggested action
Verify that:
1.
The primary IDE channel is enabled in the Configuration/Setup Utility program.
2.
All cables and jumpers are installed correctly.
3.
The correct device driver is installed for the CD-ROM drive.
If the problem remains, call for service.
Diskette drive
Diskette drive in-use light
stays on, or the system
bypasses the diskette drive.
If there is a diskette in the drive, verify that:
1.
The diskette drive is enabled in the Configuration/Setup Utility program.
2.
The diskette is good and not damaged. (Try another diskette if you have one.)
3.
The diskette contains the necessary files to start the server.
4.
Your software program is working properly.
If the diskette drive in-use light stays on, or the system continues to bypass the diskette
drive, call for service.
General problems
Call for service.
Problems such as broken
cover locks or indicator
lights not working.
Table 4. Troubleshooting charts.
Chapter 5. Solving Problems
35
Device
Intermittent problems
A problem occurs only
occasionally and is difficult
to detect.
Suggested action
Verify that:
1.
All cables and cords are connected securely to the rear of the server and attached
options.
2.
When the server is turned on, air is flowing from the rear of the server at the fan grill.
If there is no air flow, the fan is not working. This causes the server to overheat and
shut down.
3.
Ensure that the SCSI bus and devices are configured correctly and that the last
external device in each SCSI chain is terminated correctly.
If the items above are correct, call for service.
Keyboard, mouse, or
1. Make sure that the keyboard cable is properly connected to the server.
pointing-device problems.
2. Make sure that the server and the monitor are turned on.
All or some keys on the
3. Try using another keyboard.
keyboard do not work.
If the items above are correct, call for service.
The mouse or pointing
device does not work.
1.
Verify that the mouse or pointing-device cable is securely connected and the device
drivers are installed correctly.
2.
Try using another mouse or pointing device.
If the problem remains, call for service.
Memory problems
Verify that:
1.
The amount of memory
displayed is less than the
2.
amount of memory installed.
The memory modules are seated properly.
Each pair of DIMMs are the same size (DIMM 1 and DIMM 4 must match and DIMM
2 and DIMM 3 must match. The two pairs do not need to match each other.).
3.
You have installed the correct type of memory.
4.
If you changed the memory, you updated the memory configuration using the
Configuration/Setup Utility program.
5.
All banks of memory on the DIMMs are enabled. The server might have detected a
problem and automatically disabled a DIMM bank, or a DIMM bank could have been
manually disabled.
If the above items are correct, run the memory-diagnostic program. The system might
have detected a bad memory module and automatically reallocated memory to enable
you to continue to operate. If the memory tests fail, call for service or replace the failing
DIMM.
Microprocessor problems
The startup (boot) microprocessor is not working properly.
The server emits a
continuous tone during
POST.
Verify that the startup microprocessor is seated properly. If it is, call for service.
Table 4. Troubleshooting charts.
36
IBM xSeries 342: Installation Guide
Device
Monitor
Testing the monitor.
Suggested action
Some IBM monitors have their own self-tests. If you suspect a problem with your
monitor, refer to the information that comes with the monitor for adjusting and testing
instructions.
If you still cannot find the problem, call for service.
The screen is blank.
Verify that:
1.
The server power cord is plugged into the server and a working electrical outlet.
2.
The monitor cables are connected properly.
3.
The monitor is turned on and the Brightness and Contrast controls are adjusted
correctly.
If the items above are correct and the screen remains blank, call for service.
Attention: In some memory configurations, the 3-3-3 beep code might sound during
POST followed by a blank display screen. If this occurs and the Boot Fail Count feature
in the Start Options of the Configuration/Setup Utility is set to Enabled (its default
setting), you must restart the server three times to force the system BIOS to reset the
memory connector or bank of connectors from Disabled to Enabled.
Only the cursor appears.
Call for service.
The monitor works when
you turn on the server, but
goes blank when you start
some application programs.
Verify that:
1.
The primary monitor cable is connected to the video port.
2.
You installed the necessary device drivers for the applications.
If the items above are correct and the screen remains blank, call for service.
Wavy, unreadable, rolling,
distorted screen, or screen
jitter.
If the monitor self-tests show the monitor is working properly, consider the location of the
monitor. Magnetic fields around other devices (such as transformers, appliances,
fluorescent lights, and other monitors) can cause screen jitter or wavy, unreadable,
rolling, or distorted screen images. If this happens, turn off the monitor. (Moving a color
monitor while it is turned on might cause screen discoloration.) Then move the device
and the monitor at least 305 mm (12 in.) apart. Turn on the monitor.
Notes:
1.
To prevent diskette drive read/write errors, be sure the distance between monitors
and diskette drives is at least 76 mm (3 in.).
2.
Non-IBM monitor cables might cause unpredictable problems.
3.
An enhanced monitor cable with additional shielding is available for the 9521 and
9527 monitors. For information about the enhanced monitor cable, see your IBM
reseller or IBM marketing representative.
If the problem remains, call for service.
Wrong characters appear on
the screen.
If the wrong language is displayed, update the BIOS code with the correct language.
If the problem remains, call for service.
Table 4. Troubleshooting charts.
Chapter 5. Solving Problems
37
Device
Option problems
An IBM option that was just
installed does not work.
Suggested action
Verify that:
1.
The option is designed for the server. Refer to the "Support for xSeries Servers"
flowchart for information about obtaining ServerProven™ compatibility information
from the World Wide Web.
2.
You followed the installation instructions that came with the option.
3.
The option is installed correctly.
4.
You have not loosened any other installed options or cables.
5.
You updated the configuration information in the Configuration/Setup Utility
program. Whenever memory or an option is changed, you must update the
configuration.
If the problem remains, call for service.
An IBM option that used to
work does not work now.
Verify that all of the option hardware and cable connections are secure.
If the option comes with its own test instructions, use those instructions to test the option.
If the failing option is a SCSI option, verify that:
1.
The cables for all external SCSI options are connected correctly.
2.
The last option in each SCSI chain, or the end of the SCSI cable, is terminated
correctly.
3.
Any external SCSI option is turned on. You must turn on an external SCSI option
before turning on the server.
If the problem remains, call for service.
Power problems
The server does not power
on.
Verify that:
1.
The power cables are properly connected to the server.
2.
The electrical outlet functions properly.
3.
The type of memory installed is correct.
4.
If you just installed an option, remove it, and restart the server. If the server now
powers on, you might have installed more options than the power supply supports.
5.
The LEDs on the power supply are on.
If the problem remains, call for service.
Printer problems
The printer does not work.
Verify that:
1.
2.
The printer is turned on and is online.
The printer signal cable is connected to the correct port on the server.
Note:
Non-IBM printer cables might cause unpredictable problems.
3.
You have assigned the printer port correctly in your operating system or application
program.
4.
You have assigned the printer port correctly using the Configuration/Setup Utility
program.
If the items above are correct and the printer still does not work, run the tests described
in the documentation that comes with your printer. If the tests show that the printer is
working properly, call for service.
Table 4. Troubleshooting charts.
38
IBM xSeries 342: Installation Guide
Device
Serial port problems
The number of serial ports
identified by the operating
system is less than the
number of serial ports
installed.
Suggested action
Verify that:
1.
Each port is assigned a unique address by the Configuration/Setup Utility program
and none of the serial ports are disabled.
Note:
2.
The management C connector is the same as a serial port connector, but it
is used only by the Integrated System Management Processor, and is not
available for use by the operating system. This port does not appear in the
Configuration/Setup Utility program menus; it can be configured using
xSeries Manager.
The serial-port adapter, if you installed one, is seated properly.
If the problem still exists, call for service.
A serial device does not
work.
Verify that:
1.
The device is compatible with the server.
2.
The serial port is enabled and is assigned a unique address.
3.
Make sure that the device is not connected to the management port C.
Note:
The management C connector is the same as a serial port connector, but it
is used only by the Integrated System Management Processor, and is not
available for use by the operating system. This port does not appear in the
Configuration/Setup Utility program menus; it can be configured using
xSeries Manager.
If the problem still exists, call for service.
Software problem
Suspected software
problem.
To determine if problems are caused by the software, verify that:
1.
Your server has the minimum memory requirements needed to use the software.
For memory requirements, refer to the information that comes with the software.
Note:
If you have just installed an adapter or memory, you might have a memory
address conflict.
2.
The software is designed to operate on your server.
3.
Other software works on your server.
4.
The software that you are using works on another system.
If you received any error messages when using the software program, refer to the
information that comes with the software for a description of the messages and solutions
to the problem.
If the items above are correct and the problem remains, contact your place of purchase.
Universal Serial Bus
(USB) port problems
Verify that:
1.
A USB device does not
work.
You are not trying to use a USB device during POST if you have a standard (nonUSB) keyboard attached to the keyboard port.
Note:
If a standard (non-USB) keyboard is attached to the keyboard port, then the
USB is disabled and no USB device will work during POST.
2.
The correct USB device driver is installed.
3.
Your operating system supports USB devices.
If the problem still exists, call for service.
Table 4. Troubleshooting charts.
Chapter 5. Solving Problems
39
40
IBM xSeries 342: Installation Guide
Appendix A.
Product warranties and notices
This chapter contains warranty and emission notices. It also contains trademarks and
general-information notices.
Warranty Information
This section contains the warranty period for your product and the IBM Statement of
Limited Warranty.
Warranty Period
Contact your place of purchase for warranty service information. Some IBM Machines
are eligible for on-site warranty service depending on the country or region where
service is performed.
Machine - IBM®
xSeries 342
Warranty Period - Parts - 3 years, labor - 3 years
IBM Statement of Limited Warranty
Z125-4753-06 8/2000
Part 1 - General Terms
This Statement of Limited Warranty includes Part 1 - General Terms and Part 2 Country-unique Terms. The terms of Part 2 replace or modify those of Part 1. The
warranties provided by IBM in this Statement of Limited Warranty apply only to
Machines you purchase for your use, and not for resale, from IBM or your reseller.
The term "Machine" means an IBM machine, its features, conversions, upgrades,
elements, or accessories, or any combination of them. The term "Machine" does not
include any software programs, whether pre-loaded with the Machine, installed
subsequently or otherwise. Unless IBM specifies otherwise, the following warranties
apply only in the country where you acquire the Machine. Nothing in this Statement of
Limited Warranty affects any statutory rights of consumers that cannot be waived or
limited by contract. If you have any questions, contact IBM or your reseller.
The IBM Warranty for Machines
IBM warrants that each Machine 1) is free from defects in materials and workmanship
and 2) conforms to IBM’s Official Published Specifications ("Specifications"). The
warranty period for a Machine is a specified, fixed period commencing on its Date of
Installation. The date on your sales receipt is the Date of Installation unless IBM or
your reseller informs you otherwise.
If a Machine does not function as warranted during the warranty period, and IBM or
your reseller are unable to either 1) make it do so or 2) replace it with one that is at
least functionally equivalent, you may return it to your place of purchase and your
money will be refunded.
Extent of Warranty
The warranty does not cover the repair or exchange of a Machine resulting from
misuse, accident, modification, unsuitable physical or operating environment,
improper maintenance by you, or failure caused by a product for which IBM is not
© Copyright IBM Corp. 2001
41
responsible. The warranty is voided by removal or alteration of Machine or parts
identification labels.
THESE WARRANTIES ARE YOUR EXCLUSIVE WARRANTIES AND REPLACE
ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR
CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS AND
YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO
JURISDICTION. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF EXPRESS OR IMPLIED WARRANTIES, SO THE ABOVE
EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU. IN THAT EVENT, SUCH
WARRANTIES ARE LIMITED IN DURATION TO THE WARRANTY PERIOD. NO
WARRANTIES APPLY AFTER THAT PERIOD.
Items Not Covered by Warranty
IBM does not warrant uninterrupted or error-free operation of a Machine.
Any technical or other support provided for a Machine under warranty, such as
assistance via telephone with "how-to" questions and those regarding Machine set-up
and installation, will be provided WITHOUT WARRANTIES OF ANY KIND.
Warranty Service
To obtain warranty service for a Machine, contact IBM or your reseller. If you do not
register your Machine with IBM, you may be required to present proof of purchase.
During the warranty period, IBM or your reseller, if approved by IBM to provide
warranty service, provides without charge certain types of repair and exchange
service to keep Machines in, or restore them to, conformance with their
Specifications. IBM or your reseller will inform you of the available types of service for
a Machine based on its country of installation. At its discretion, IBM or your reseller
will 1) either repair or exchange the failing Machine and 2) provide the service either
at your location or a service center. IBM or your reseller will also manage and install
selected engineering changes that apply to the Machine.
Some parts of IBM Machines are designated as Customer Replaceable Units (called
"CRUs"), e.g., keyboards, memory, or hard disk drives. IBM ships CRUs to you for
replacement by you. You must return all defective CRUs to IBM within 30 days of your
receipt of the replacement CRU. You are responsible for downloading designated
Machine Code and Licensed Internal Code updates from an IBM Internet Web site or
from other electronic media, and following the instructions that IBM provides.
When warranty service involves the exchange of a Machine or part, the item IBM or
your reseller replaces becomes its property and the replacement becomes yours. You
represent that all removed items are genuine and unaltered. The replacement may
not be new, but will be in good working order and at least functionally equivalent to the
item replaced. The replacement assumes the warranty service status of the replaced
item. Many features, conversions, or upgrades involve the removal of parts and their
return to IBM. A part that replaces a removed part will assume the warranty service
status of the removed part.
Before IBM or your reseller exchanges a Machine or part, you agree to remove all
features, parts, options, alterations, and attachments not under warranty service.
You also agree to
42
IBM xSeries 342: Installation Guide
1. ensure that the Machine is free of any legal obligations or restrictions that prevent
its exchange;
2. obtain authorization from the owner to have IBM or your reseller service a
Machine that you do not own; and
3. where applicable, before service is provided:
a. follow the problem determination, problem analysis, and service request
procedures that IBM or your reseller provides;
b. secure all programs, data, and funds contained in a Machine;
c. provide IBM or your reseller with sufficient, free, and safe access to your
facilities to permit them to fulfill their obligations; and
d. inform IBM or your reseller of changes in a Machine’s location.
IBM is responsible for loss of, or damage to, your Machine while it is 1) in IBM’s
possession or 2) in transit in those cases where IBM is responsible for the
transportation charges.
Neither IBM nor your reseller is responsible for any of your confidential, proprietary or
personal information contained in a Machine which you return to IBM or your reseller
for any reason. You should remove all such information from the Machine prior to its
return.
Limitation of Liability
Circumstances may arise where, because of a default on IBM’s part or other liability,
you are entitled to recover damages from IBM. In each such instance, regardless of
the basis on which you are entitled to claim damages from IBM (including
fundamental breach, negligence, misrepresentation, or other contract or tort claim),
except for any liability that cannot be waived or limited by applicable laws, IBM is
liable for no more than
1. damages for bodily injury (including death) and damage to real property and
tangible personal property; and
2. the amount of any other actual direct damages, up to the charges (if recurring, 12
months’ charges apply) for the Machine that is subject of the claim. For purposes
of this item, the term "Machine" includes Machine Code and Licensed Internal
Code.
This limit also applies to IBM’s suppliers and your reseller. It is the maximum for
which IBM, its suppliers, and your reseller are collectively responsible.
UNDER NO CIRCUMSTANCES IS IBM LIABLE FOR ANY OF THE FOLLOWING:
1) THIRD-PARTY CLAIMS AGAINST YOU FOR DAMAGES (OTHER THAN THOSE
UNDER THE FIRST ITEM LISTED ABOVE); 2) LOSS OF, OR DAMAGE TO, YOUR
RECORDS OR DATA; OR 3) SPECIAL, INCIDENTAL, OR INDIRECT DAMAGES
OR FOR ANY ECONOMIC CONSEQUENTIAL DAMAGES, LOST PROFITS OR
LOST SAVINGS, EVEN IF IBM, ITS SUPPLIERS OR YOUR RESELLER IS
INFORMED OF THEIR POSSIBILITY. SOME JURISDICTIONS DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO
YOU.
Governing Law
Both you and IBM consent to the application of the laws of the country in which you
acquired the Machine to govern, interpret, and enforce all of your and IBM’s rights,
duties, and obligations arising from, or relating in any manner to, the subject matter of
this Agreement, without regard to conflict of law principles.
Appendix A. Product warranties and notices
43
Part 2 - Country-unique Terms
AMERICAS
BRAZIL
Governing Law: The following is added after the first sentence:
Any litigation arising from this Agreement will be settled exclusively by the court of Rio
de Janeiro.
NORTH AMERICA
Warranty Service: The following is added to this Section:
To obtain warranty service from IBM in Canada or the United States, call 1-800-IBMSERV (426-7378).
CANADA
Governing Law: The following replaces "laws of the country in which you acquired
the Machine" in the first sentence:
laws in the Province of Ontario.
UNITED STATES
Governing Law: The following replaces "laws of the country in which you acquired
the Machine" in the first sentence:
laws of the State of New York.
ASIA PACIFIC
AUSTRALIA
The IBM Warranty for Machines: The following paragraph is added to this Section:
The warranties specified in this Section are in addition to any rights you may have
under the Trade Practices Act 1974 or other similar legislation and are only limited to
the extent permitted by the applicable legislation.
Limitation of Liability: The following is added to this Section:
Where IBM is in breach of a condition or warranty implied by the Trade Practices Act
1974 or other similar legislation, IBM’s liability is limited to the repair or replacement of
the goods or the supply of equivalent goods. Where that condition or warranty relates
to right to sell, quiet possession or clear title, or the goods are of a kind ordinarily
acquired for personal, domestic or household use or consumption, then none of the
limitations in this paragraph apply.
Governing Law: The following replaces "laws of the country in which you acquired
the Machine" in the first sentence:
laws of the State or Territory.
CAMBODIA, LAOS, AND VIETNAM
Governing Law: The following replaces "laws of the country in which you acquired
the Machine" in the first sentence:
laws of the State of New York.
The following is added to this Section:
Disputes and differences arising out of or in connection with this Agreement shall be
finally settled by arbitration which shall be held in Singapore in accordance with the
rules of the International Chamber of Commerce (ICC). The arbitrator or arbitrators
designated in conformity with those rules shall have the power to rule on their own
44
IBM xSeries 342: Installation Guide
competence and on the validity of the Agreement to submit to arbitration. The
arbitration award shall be final and binding for the parties without appeal and the
arbitral award shall be in writing and set forth the findings of fact and the conclusions
of law.
All proceedings shall be conducted, including all documents presented in such
proceedings, in the English language. The number of arbitrators shall be three, with
each side to the dispute being entitled to appoint one arbitrator.
The two arbitrators appointed by the parties shall appoint a third arbitrator before
proceeding upon the reference. The third arbitrator shall act as chairman of the
proceedings. Vacancies in the post of chairman shall be filled by the president of the
ICC. Other vacancies shall be filled by the respective nominating party. Proceedings
shall continue from the stage they were at when the vacancy occurred.
If one of the parties refuses or otherwise fails to appoint an arbitrator within 30 days of
the date the other party appoints its, the first appointed arbitrator shall be the sole
arbitrator, provided that the arbitrator was validly and properly appointed.
The English language version of this Agreement prevails over any other language
version.
HONG KONG AND MACAU
Governing Law: The following replaces "laws of the country in which you acquired
the Machine" in the first sentence:
laws of Hong Kong Special Administrative Region.
INDIA
Limitation of Liability: The following replaces items 1 and 2 of this Section:
1. liability for bodily injury (including death) or damage to real property and tangible
personal property will be limited to that caused by IBM’s negligence;
2. as to any other actual damage arising in any situation involving nonperformance
by IBM pursuant to, or in any way related to the subject of this Statement of
Limited Warranty, IBM’s liability will be limited to the charge paid by you for the
individual Machine that is the subject of the claim.
JAPAN
Governing Law: The following sentence is added to this Section:
Any doubts concerning this Agreement will be initially resolved between us in good
faith and in accordance with the principle of mutual trust.
NEW ZEALAND
The IBM Warranty for Machines: The following paragraph is added to this Section:
The warranties specified in this Section are in addition to any rights you may have
under the Consumer Guarantees Act 1993 or other legislation which cannot be
excluded or limited. The Consumer Guarantees Act 1993 will not apply in respect of
any goods which IBM provides, if you require the goods for the purposes of a
business as defined in that Act.
Limitation of Liability: The following is added to this Section:
Where Machines are not acquired for the purposes of a business as defined in the
Consumer Guarantees Act 1993, the limitations in this Section are subject to the
limitations in that Act.
Appendix A. Product warranties and notices
45
PEOPLE’S REPUBLIC OF CHINA (PRC)
Governing Law: The following replaces this Section:
Both you and IBM consent to the application of the laws of the State of New York
(except when local law requires otherwise) to govern, interpret, and enforce all your
and IBM’s rights, duties, and obligations arising from, or relating in any manner to, the
subject matter of this Agreement, without regard to conflict of law principles.
Any disputes arising from or in connection with this Agreement will first be resolved by
friendly negotiations, failing which either of us has the right to submit the dispute to
the China International Economic and Trade Arbitration Commission in Beijing, the
PRC, for arbitration in accordance with its arbitration rules in force at the time. The
arbitration tribunal will consist of three arbitrators. The language to be used therein
will be English and Chinese. An arbitral award will be final and binding on all the
parties, and will be enforceable under the Convention on the Recognition and
Enforcement of Foreign Arbitral Awards (1958).
The arbitration fee will be borne by the losing party unless otherwise determined by
the arbitral award.
During the course of arbitration, this Agreement will continue to be performed except
for the part which the parties are disputing and which is undergoing arbitration.
EUROPE, MIDDLE EAST, AFRICA (EMEA)
THE FOLLOWING TERMS APPLY TO ALL EMEA COUNTRIES:
The terms of this Statement of Limited Warranty apply to Machines purchased from
IBM or an IBM reseller.
Warranty Service:
If you purchase an IBM Machine in Austria, Belgium, Denmark, Estonia, Finland,
France, Germany, Greece, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg,
Netherlands, Norway, Portugal, Spain, Sweden, Switzerland or United Kingdom, you
may obtain warranty service for that Machine in any of those countries from either (1)
an IBM reseller approved to perform warranty service or (2) from IBM. If you purchase
an IBM Personal Computer Machine in Albania, Armenia, Belarus, Bosnia and
Herzegovina, Bulgaria, Croatia, Czech Republic, Georgia, Hungary, Kazakhstan,
Kirghizia, Federal Republic of Yugoslavia, Former Yugoslav Republic of Macedonia
(FYROM), Moldova, Poland, Romania, Russia, Slovak Republic, Slovenia, or
Ukraine, you may obtain warranty service for that Machine in any of those countries
from either (1) an IBM reseller approved to perform warranty service or (2) from IBM.
If you purchase an IBM Machine in a Middle Eastern or African country, you may
obtain warranty service for that Machine from the IBM entity within the country of
purchase, if that IBM entity provides warranty service in that country, or from an IBM
reseller, approved by IBM to perform warranty service on that Machine in that country.
Warranty service in Africa is available within 50 kilometers of an IBM authorized
service provider. You are responsible for transportation costs for Machines located
outside 50 kilometers of an IBM authorized service provider.
Governing Law:
The applicable laws that govern, interpret and enforce rights, duties, and obligations
of each of us arising from, or relating in any manner to, the subject matter of this
Statement, without regard to conflict of laws principles, as well as Country-unique
terms and competent court for this Statement are those of the country in which the
warranty service is being provided, except that in 1) Albania, Bosnia-Herzegovina,
Bulgaria, Croatia, Hungary, Former Yugoslav Republic of Macedonia, Romania,
46
IBM xSeries 342: Installation Guide
Slovakia, Slovenia, Armenia, Azerbaijan, Belarus, Georgia, Kazakhstan, Kyrgyzstan,
Moldova, Russia, Tajikistan, Turkmenistan, Ukraine, and Uzbekistan, the laws of
Austria apply; 2) Estonia, Latvia, and Lithuania, the laws of Finland apply; 3) Algeria,
Benin, Burkina Faso, Cameroon, Cape Verde, Central African Republic, Chad,
Congo, Djibouti, Democratic Republic of Congo, Equatorial Guinea, France, Gabon,
Gambia, Guinea, Guinea-Bissau, Ivory Coast, Lebanon, Mali, Mauritania, Morocco,
Niger, Senegal, Togo, and Tunisia, this Agreement will be construed and the legal
relations between the parties will be determined in accordance with the French laws
and all disputes arising out of this Agreement or related to its violation or execution,
including summary proceedings, will be settled exclusively by the Commercial Court
of Paris; 4) Angola, Bahrain, Botswana, Burundi, Egypt, Eritrea, Ethiopia, Ghana,
Jordan, Kenya, Kuwait, Liberia, Malawi, Malta, Mozambique, Nigeria, Oman,
Pakistan, Qatar, Rwanda, Sao Tome, Saudi Arabia, Sierra Leone, Somalia, Tanzania,
Uganda, United Arab Emirates, United Kingdom, West Bank/Gaza, Yemen, Zambia,
and Zimbabwe, this Agreement will be governed by English Law and disputes relating
to it will be submitted to the exclusive jurisdiction of the English courts; and 5) in
Greece, Israel, Italy, Portugal, and Spain any legal claim arising out of this Statement
will be brought before, and finally settled by, the competent court of Athens, Tel Aviv,
Milan, Lisbon, and Madrid, respectively.
THE FOLLOWING TERMS APPLY TO THE COUNTRY SPECIFIED:
AUSTRIA AND GERMANY
The IBM Warranty for Machines: The following replaces the first sentence of the first
paragraph of this Section:
The warranty for an IBM Machine covers the functionality of the Machine for its
normal use and the Machine’s conformity to its Specifications.
The following paragraphs are added to this Section:
The minimum warranty period for Machines is six months. In case IBM or your reseller
is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far
as justified by the reduced value of the unrepaired Machine or ask for a cancellation of
the respective agreement for such Machine and get your money refunded.
Extent of Warranty: The second paragraph does not apply.
Warranty Service: The following is added to this Section:
During the warranty period, transportation for delivery of the failing Machine to IBM
will be at IBM’s expense.
Limitation of Liability: The following paragraph is added to this Section:
The limitations and exclusions specified in the Statement of Limited Warranty will not
apply to damages caused by IBM with fraud or gross negligence and for express
warranty.
The following sentence is added to the end of item 2:
IBM’s liability under this item is limited to the violation of essential contractual terms in
cases of ordinary negligence.
EGYPT
Limitation of Liability: The following replaces item 2 in this Section:
as to any other actual direct damages, IBM's liability will be limited to the total amount
you paid for the Machine that is the subject of the claim. For purposes of this item, the
term "Machine" includes Machine Code and Licensed Internal Code.
Applicability of suppliers and resellers (unchanged).
Appendix A. Product warranties and notices
47
FRANCE
Limitation of Liability: The following replaces the second sentence of the first
paragraph of this Section:
In such instances, regardless of the basis on which you are entitled to claim damages
from IBM, IBM is liable for no more than: (items 1 and 2 unchanged).
IRELAND
Extent of Warranty: The following is added to this Section:
Except as expressly provided in these terms and conditions, all statutory conditions,
including all warranties implied, but without prejudice to the generality of the foregoing
all warranties implied by the Sale of Goods Act 1893 or the Sale of Goods and Supply
of Services Act 1980 are hereby excluded.
Limitation of Liability: The following replaces items one and two of the first
paragraph of this Section:
1. death or personal injury or physical damage to your real property solely caused by
IBM’s negligence; and
2. the amount of any other actual direct damages, up to 125 percent of the charges (if
recurring, the 12 months’ charges apply) for the Machine that is the subject of the
claim or which otherwise gives rise to the claim.
Applicability of suppliers and resellers (unchanged).
The following paragraph is added at the end of this Section:
IBM’s entire liability and your sole remedy, whether in contract or in tort, in respect of
any default shall be limited to damages.
ITALY
Limitation of Liability: The following replaces the second sentence in the first
paragraph:
In each such instance unless otherwise provided by mandatory law, IBM is liable for
no more than:
1. (unchanged)
2. as to any other actual damage arising in all situations involving nonperformance by
IBM pursuant to, or in any way related to the subject matter of this Statement of
Warranty, IBM’s liability, will be limited to the total amount you paid for the Machine
that is the subject of the claim.
Applicability of suppliers and resellers (unchanged).
The following replaces the third paragraph of this Section:
Unless otherwise provided by mandatory law, IBM and your reseller are not liable for
any of the following: (items 1 and 2 unchanged) 3) indirect damages, even if IBM or
your reseller is informed of their possibility.
SOUTH AFRICA, NAMIBIA, BOTSWANA, LESOTHO AND SWAZILAND
Limitation of Liability: The following is added to this Section:
IBM’s entire liability to you for actual damages arising in all situations involving
nonperformance by IBM in respect of the subject matter of this Statement of Warranty
will be limited to the charge paid by you for the individual Machine that is the subject
of your claim from IBM.
UNITED KINGDOM
Limitation of Liability: The following replaces items 1 and 2 of the first paragraph of
this Section:
48
IBM xSeries 342: Installation Guide
1. death or personal injury or physical damage to your real property solely caused
by IBM’s negligence;
2. the amount of any other actual direct damages or loss, up to 125 percent of the
charges (if recurring, the 12 months’ charges apply) for the Machine that is the
subject of the claim or which otherwise gives rise to the claim;
The following item is added to this paragraph:
3. breach of IBM’s obligations implied by Section 12 of the Sale of Goods Act 1979 or
Section 2 of the Supply of Goods and Services Act 1982.
Applicability of suppliers and resellers (unchanged).
The following is added to the end of this Section:
IBM’s entire liability and your sole remedy, whether in contract or in tort, in respect of
any default shall be limited to damages.
Notices
This publication was developed for products and services offered in the U.S.A.
IBM may not offer the products, services, or features discussed in this document in
other countries. Consult your local IBM representative for information on the products
and services currently available in your area. Any reference to an IBM product,
program, or service is not intended to state or imply that only that IBM product,
program, or service may be used. Any functionally equivalent product, program, or
service that does not infringe any IBM intellectual property right may be used instead.
However, it is the user’s responsibility to evaluate and verify the operation of any nonIBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter
described in this document. The furnishing of this document does not give you any
license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. Some states do not allow disclaimer of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. IBM may make improvements and/or
changes in the product(s) and/or the program(s) described in this publication at any
time without notice.
Any references in this publication to non-IBM Web sites are provided for convenience
only and do not in any manner serve as an endorsement of those Web sites. The
materials at those Web sites are not part of the materials for this IBM product, and use
of those Web sites is at your own risk.
Appendix A. Product warranties and notices
49
IBM may use or distribute any of the information you supply in any way it believes
appropriate without incurring any obligation to you.
Edition notice
© COPYRIGHT INTERNATIONAL BUSINESS MACHINES CORPORATION, 2001.
All rights reserved.
Note to U.S. Government Users — Documentation related to restricted rights — Use,
duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule
Contract with IBM Corp.
Processing date data
This IBM hardware product and IBM software products that might be packaged with it
have been designed, when used in accordance with their associated documentation,
to process date data correctly within and between the 20th and 21st centuries,
provided all other products (for example, software, hardware, and firmware) used with
these products properly exchange accurate date data with them.
IBM cannot take responsibility for the date data processing capabilities of non-IBM
products, even if those products are preinstalled or otherwise distributed by IBM. You
should contact the vendors responsible for those products directly to determine the
capabilities of their products and update them if needed. This IBM hardware product
cannot prevent errors that might occur if software, upgrades, or peripheral devices
you use or exchange data with do not process date data correctly.
The foregoing is a Year 2000 Readiness Disclosure.
Trademarks
The following terms are trademarks of the IBM Corporation in the United States, other
countries, or both:
Alert on LAN
xSeries
e-business logo
ServeRAID
EtherJet
ServerGuide
HelpCenter
ServerProven
IBM
TechConnect
Wake on LAN
Update Connector
Intel, Pentium, and Pentium III are trademarks of Intel Corporation in the United
States, other countries, or both.
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the
United States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other
countries.
Java and all Java-based trademarks and logos are trademarks or registered
trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
Other company, product, and service names may be trademarks or service marks of
others.
50
IBM xSeries 342: Installation Guide
Important notes
Processor speeds indicate the internal clock speed of the microprocessor; other
factors also affect application performance.
When referring to hard disk drive capacity, MB stands for 1000000 bytes and GB
stands for 1000000000 bytes. Total user-accessible capacity may vary depending on
operating environments.
Maximum internal hard disk drive capacities assume the replacement of any standard
hard disk drives and population of all hard disk drive bays with the largest currently
supported drives available from IBM.
Unless otherwise stated, IBM makes no representations or warranties with respect to
non-IBM products. Support (if any) for the non-IBM products is provided by the third
party, not IBM.
Some software may differ from its retail version (if available), and may not include
user manuals or all program functionality.
IBM makes no representations or warranties regarding non-IBM products and
services that are ServerProven, including but not limited to the implied warranties of
merchantability and fitness for particular purpose. Warranty, service and support for
these products and services are provided by third parties, not IBM.
Electronic emission notices
Federal Communications Commission (FCC) Statement
Note: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his
own expense.
Properly shielded and grounded cables and connectors must be used in order to meet
FCC emission limits. IBM is not responsible for any radio or television interference
caused by using other than recommended cables and connectors or by unauthorized
changes or modifications to this equipment. Unauthorized changes or modifications
could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Industry Canada Class A emission compliance statement
This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformité à la réglementation d'Industrie Canada
Cet appareil numérique de classe A est conforme à la norme NMB-003 du Canada.
Appendix A. Product warranties and notices
51
Australia and New Zealand Class A statement
Attention: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate
measures.
United Kingdom telecommunications safety requirement
Notice to Customers
This apparatus is approved under approval number NS/G/1234/J/100003 for indirect
connection to public telecommunication systems in the United Kingdom.
European Union EMC Directive conformance statement
This product is in conformity with the protection requirements of EU Council Directive
89/336/EEC on the approximation of the laws of the Member States relating to
electromagnetic compatibility. IBM cannot accept responsibility for any failure to
satisfy the protection requirements resulting from a nonrecommended modification of
the product, including the fitting of non-IBM option cards.
This product has been tested and found to comply with the limits for Class A
Information Technology Equipment according to CISPR 22/European Standard EN
55022. The Limits for Class A equipment were derived for commercial and industrial
environments to provide reasonable protection against interference with licensed
communication equipment.
Attention: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate
measures.
Taiwan electrical emission statement
Japanese Voluntary Control Council for Interference (VCCI) statement
52
IBM xSeries 342: Installation Guide
Power cords
For your safety, IBM provides a power cord with a grounded attachment plug to use
with this IBM product. To avoid electrical shock, always use the power cord and plug
with a properly grounded outlet.
IBM power cords used in the United States and Canada are listed by Underwriter’s
Laboratories (UL) and certified by the Canadian Standards Association (CSA).
For units intended to be operated at 115 volts: Use a UL-listed and CSA-certified cord
set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a
maximum of 15 feet in length and a parallel blade, grounding-type attachment plug
rated 15 amperes, 125 volts.
For units intended to be operated at 230 volts (U.S. use): Use a UL-listed and CSAcertified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor
cord, a maximum of 15 feet in length and a tandem blade, grounding-type attachment
plug rated 15 amperes, 250 volts.
For units intended to be operated at 230 volts (outside the U.S.): Use a cord set with a
grounding-type attachment plug. The cord set should have the appropriate safety
approvals for the country in which the equipment will be installed.
IBM power cords for a specific country or region are usually available only in that
country or region.
IBM power cord part
number
Used in these countries and regions
13F9940
Argentina, Australia, China (PRC), New Zealand, Papua New
Guinea, Paraguay, Uruguay, Western Samoa
13F9979
Afghanistan, Algeria, Andorra, Angola, Austria, Belgium, Benin,
Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Rep.,
Chad, China (Macau S.A.R.), Czech Republic, Egypt, Finland,
France, French Guiana, Germany, Greece, Guinea, Hungary,
Iceland, Indonesia, Iran, Ivory Coast, Jordan, Lebanon,
Luxembourg, Malagasy, Mali, Martinique, Mauritania, Mauritius,
Monaco, Morocco, Mozambique, Netherlands, New Caledonia,
Niger, Norway, Poland, Portugal, Romania, Senegal, Slovakia,
Spain, Sudan, Sweden, Syria, Togo, Tunisia, Turkey, former USSR,
Vietnam, former Yugoslavia, Zaire, Zimbabwe
13F9997
Denmark
14F0015
Bangladesh, Burma, Pakistan, South Africa, Sri Lanka
14F0033
Antigua, Bahrain, Brunei, Channel Islands, China (Hong Kong
S.A.R.), Cyprus, Dubai, Fiji, Ghana, India, Iraq, Ireland, Kenya,
Kuwait, Malawi, Malaysia, Malta, Nepal, Nigeria, Polynesia, Qatar,
Sierra Leone, Singapore, Tanzania, Uganda, United Kingdom,
Yemen, Zambia
14F0051
Liechtenstein, Switzerland
14F0069
Chile, Ethiopia, Italy, Libya, Somalia
14F0087
Israel
1838574
Thailand
Appendix A. Product warranties and notices
53
IBM power cord part
number
6952301
54
IBM xSeries 342: Installation Guide
Used in these countries and regions
Bahamas, Barbados, Bermuda, Bolivia, Brazil, Canada, Cayman
Islands, Colombia, Costa Rica, Dominican Republic, Ecuador, El
Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan,
Korea (South), Liberia, Mexico, Netherlands Antilles, Nicaragua,
Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan,
Trinidad (West Indies), United States of America, Venezuela
Index
A
F
AC power 24
AC power light 24
acoustical noise emissions 2
adapter
considerations 7
installing 8
PCI bus, which 8
ServeRAID 9
air baffle 14
FCC Class A notice 51
features 2
filler panel
power supply bay 16
B
bezel
removing 6
C
cabling, ServeRAID adapter 9
CD-ROM drive 2
Class A electronic emission notice 51
components
color 4
major 4
configuration
Configuration/Setup Utility 27
SCSISelect utility 27
ServeRAID programs 27
ServerGuide CDs 27
Configuration/Setup Utility 27
controls on front of server 23
cooling 2
cover
removing 6
D
DC power light 24
diagnostic tools 31
DIMM. See memory module
diskette drive 2
drive
installing
hot-swap 11
E
electrical input 2
electronic emission Class A notice 51
environment 2
error messages. See messages
Ethernet transmit/receive activity light 24
© Copyright IBM Corp. 2001
H
hard disk drive activity light 23
hard disk drive status light 23
heat output 2
hot-swap drive
installing 11
specifications 2
hot-swap power supply
installing 15
I
important notes 51
indicators on front of server 23
information light 25
L
light
DC power 24
Ethernet transmit/receive activity 24
information 25
on front of server 24
on operator information panel 24
SCSI hard disk drive activity 24
system information 25
system power 23
light. See also LED
M
major components 4
memory module
installing 16
specifications 2
supported 16
messages
POST 33
microprocessor
installing 11
specifications 2
55
N
non-hot-swap drive
specifications 2
NOS See operating system 29
notices
electronic emission, Class A 51
FCC, Class A 51
miscellaneous 51
product 51
trademarks 50
O
operating system
installing 29
operator information panel 23, 24
T
trademarks 50
troubleshooting chart 35
turning off the server 22
P
PCI
bus A 8
bus B 8
PCI expansion slots 2
locations 7
POST
error messages 33
messages 33
power control button 23
power cords 53
power supply
specifications 2
power supply, installing 15
product
notices 51
PXE Boot Agent Utility 27
U
United States electronic emission Class A notice 51
United States FCC Class A notice 51
utility
Configuration/Setup 27
V
video 2
voltage regulator module, installing 13
VRM, installing 13
W
R
reset button 23
S
safety information
electrical vii
laser viii
lifting ix
safety requirements
electronic emission Class A notice 51
FCC Class A notice 51
SCSI hard disk drive activity light 24
SCSISelect Utility 27
SCSISelect utility program
starting 28
ServeRAID adapter
cable 9
56
ServeRAID programs 27
ServerGuide
CDs 29
using 29
ServerGuide CDs 27
shutting down the server 22
size 2
software coupon
ServerGuide 29
specifications 2
starting server 21
static electricity 3
static sensitive devices, handling 3
stopping the server 22
system error light 25
system power light 23
IBM xSeries 342: Installation Guide
Web site
ServerGuide 29
weight 2
IBM
Part Number: 24P2880
Printed in the United States of America
24P288
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project