Datasheet_RFUS
Switch unit for outdoor use RFUS-61
• The switching unit with 1 output channel is used for controlling appliances, sockets or lights.
IP65
• It can be combined with Control or System units iNELS RF Control.
• The increased IP 65 protection is suited to mounting on the wall or in harsh environments such as the cellar,
60mm
21mm
garage or bathrooms.
• It enables connection of the switched load up to 12A (3.000 W).
• RFUS-61: multi-function design – button, impulse relay and time function of delayed ON or OFF with time
setting of 2s-60 min.
• The switching unit may be controlled by up to 32 channels (1 channel represents 1 button on the controller).
• The programming button on the unit is also used for manual control of the output.
• Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal
repeater RFRP-20.
• Communication frequency of with bidirectional protocol iNELS RF Control.
Technical parameters
RFUS-61/230V
RFUS-61/120V
RFUS-61/24V
Supply voltage:
230 V AC / 50 - 60 Hz 120 V AC / 60Hz 12-24 V AC/DC 50-60Hz
Apparent power:
5 VA / cos φ = 0.1 5 VA / cos φ = 0.1
0.6 W
0.6 W
0.7 W
Dissipated power:
+10 %; -15 %
Supply voltage tolerance:
Output
1 x switching (AgSnO2)
Rated current:
12 A / AC1
Number of contacts:
3000 VA / AC1, 384 W / DC
Switching power:
30 A / <3 s
Peak current:
250 V AC1 / 24 V DC
Peak current:
500 mW
Min. switching power DC:
3x107
Mechanical service life:
0.7x105
Electrical service life (AC1):
Control
868 MHz, 915 MHz, 916 MHz
RF command from the transmitter:
button PROG (ON/OFF)
Manual control:
up to 200 m
Range in open space:
Other data
-15 up to + 50 °C
Operating temperature:
any
Operating position:
screws
Mounting:
IP 65
Protection:
III.
Overvoltage category:
2
Contamination degree:
max. 1x2.5,max. 2x1.5 / with a hollow max.1x2.5
Cross-section of connecting wires (mm2)
CYKY 3x1.5 (CYKY 4x1.5)
Recommended power cord:
136 x 62 x 34 mm
Dimensions:
146 g
Weight:
EN 60669, EN 300 220, EN 301 489
Related standards:
R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC)
Function
For more information, see p. 56.
Device description
Antenna
Opening for wall
mounting Ø 4.3mm
STATUS
Programming button
(manual control)
Indication of operating and
programming mode
230V AC
PROG
Neutral conductor
Phase conductor
Output contact
relay
Opening for wall
mounting Ø 4.3mm
Bushing M16x1.5 for connecting cable
with max. diameter of 10 mm
Connection
RFUS-61/120V
RFUS-61/230V
RFUS-61/120V
RFUS-61/230V
4 - wire connection
3 - wire connection
N
L
L
N
30
RFUS-61/24V
N
L
18
15
16
L
N
4 - wire connection
18
15
16
A1
A2
galvanically
separated
contact
18
15
16
galvanically
separated
contact
12-24 V AC/DC
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement