188 3 us~v~Specification Sheet

188 3 us~v~Specification Sheet
HEAT RECOVERY VENTILATOR
HRV CONSTRUCTO 2.0ES
Part no. 47110
82 to 192 CFM (0.4 in. w.g.)
Controls
• This unit is very simple to operate. Once it is installed, press on its
push button, located on the bottom of the unit, to activate it. Press
once for low speed, once again for high speed, and once more to
stop it.
• For more convenience, this unit can also be controlled by an optional
main control. For a complete list of optional main and auxiliary
controls available, refer to the Wall Control Compatibility Chart
on last pages of wall controls specification sheet, available at
www.venmar.ca.
• For more details about controls, refer to the Main and auxiliary wall
controls user guide, also available at www.venmar.ca.
Options
• Complete line of registers and diffusers
VB0167
CONSTRUCTO® SERIES: PERFECT FOR NEW
RESIDENTIAL CONSTRUCTION
Contractors and builders need cost-effective, reliable and
code-compliant mechanical ventilation systems for new home
construction. The Venmar AVS Constructo Series offers superior value
at an entry-level price. The Constructo 2.0ES represents over 15 years
of continuous improvement to deliver contractors the durability and
reliability they have come to expect from Venmar.
Defrosting System
The HRV Constructo 2.0ES uses an efficient defrosting method. No
negative pressure is created by air exhausted to the outdoors, as the air
is recirculated into the house, helping to prevent any backdraft.
OUTDOOR TEMPERATURE
DEFROST CYCLE (MINUTES)
°C
°F
DEFROST / OPERATION
WARMER THAN -5
WARMER THAN 23
NO DEFROST
Key features:
-5 TO -15
23 TO 5
6 / 50
• Maintenance free, totally enclosed, sealed bearings motor
-15 TO -27
5 TO -17
6 / 25
-27 AND LESS
-17 AND LESS
10 / 20
• Pressure taps, balancing dampers and straps for insulated ducts for
quick, effective installation
STALE AIR
FROM BUILDING
• Integrated “snap-in” drain system installs in seconds
with no additional parts
FILTRERED AIR
TO BUILDING
• ENERGY STAR® qualified
• Compatible with the Deco-Touch™ digital wall control
VF0053
REPAIRS AND MAINTENANCE
All parts of the HRV Constructo 2.0ES that could need maintenance
can be removed in less than 5 minutes, allowing direct access for easy
repairs. The motor is permanently lubricated.
Heat Recovery Core
Dimensions: 12” x 14” x 15.5” (30.5 cm x 35.5 cm x 39.4 cm)
Exchange surface: 102 ft² (9.54 m²)
WARRANTY
Weight: 6.2 lb. (2.8 kg)
The HRV Constructo 2.0ES is protected by a 5-year warranty on parts.
The heat recovery core is covered by a limited lifetime warranty, with
the original proof of purchase.
Material: Polypropylene
Type: Crossflow core
Warranty: Limited Lifetime
Requirements and Standards
Available at:
• Complies with the UL 1812 requirements regulating the installation
of Heat Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Complies with CSA F326 requirements regulating the installation of
Heat Recovery Ventilators
• Technical data was obtained from published results of tests relating
to CSA C439 Standards
• HVI certified and ENERGY STAR® qualified
DIMENSIONS: HRV CONSTRUCTO 2.0ES
35” (891 mm)
Hooks Location
for Hanging Chains
17¼” (438 mm)
30¼” (768 mm)
Motorized
Damper
Terminal
Block
Location
17”
(432 mm)
Heat
Recovery
Core
Door
Power Cord
36” (914 mm)
VK0077A
VENTILATION PERFORMANCE
EXTERNAL STATIC
NET SUPPLY
PRESSURE
AIR FLOW
PA
IN. W.G.
L/S
CFM
M3/H
L/S
25
0.1
106 225 382 107
50
0.2
102 215 365 102
75
0.3
96 204 347 97
100
0.4
90 192 326 91
125
0.5
83 177 301 84
150
0.6
76 161 274 76
175
0.7
67 142 241 67
ENERGY PERFORMANCE
GROSS AIR FLOW
SUPPLY
EXHAUST
CFM
M3/H
L/S
CFM
227
386 118 249
216
367 115 243
205
348 111 235
193
328 107 226
179
304 100 211
162
275 89
189
143
243 75
159
SUPPLY
POWER
SENSIBLE APPARENT
NET AIR FLOW
TEMPERATURE
CONSUMED RECOVERY SENSIBLE
°C
°F L/S CFM M3/H WATTS EFFICIENCY EFFECTIVENESS
HEATING
0
32 39 82 139
71
65
75
0
32 61 130 221
129
60
69
M3/H
423
413
399
384
358
321
270
-25
-13
40 84
143
114
60
LATENT RECOVERY
MOISTURE
TRANSFER
76
0.01
0.01
0.03
100
APPARENT (%)
90
NET (%)
0.8
EFFICIENCY
EXTERNAL STATIC PRESSURE
IN. W.G. (PA = N X 248.8)
6”
(152 mm)
Blower
Assembly
0.6
0.4
70
60
50
SUPPLY (L/S)
EXHAUST (L/S)
0.2
80
40
0
0
25
0
50
75
100
125
150
175
200
225
250
25
50
75
100
VG0092
275
AIR FLOW - L/S (0.47 L/S = 1 CFM
NOTE: All specifications are subject to change without notice.
VG0091A
CFM (L/S = CFM X 0.4719) (M³/H = L/S X 3.6)
SPECIFICATIONS AND RATINGS
• Model: HRV Constructo 2.0ES
• 6" Round Ports
• Speed Control on unit: Low and High speeds.
• Part Number: 47110
• Housing: Pre-painted steel
Other modes available with optional
mainl wall controls.
• Total Assembled Weight (including
• Insulation: Expanded polystyrene
polypropylene core): 65 lb. (29.5 kg)
• Drains: 1/2" (1.2 cm) fittings with
- Heat Exchange Surface Area: 102 ft.² (9.54 m²)
• Mounting: Suspension by chains and springs
10 ft. (3 m) PVC drain hose
• Filters: 15 ppi washable reticulated foam
- Type: Crossflow
- Material: Polypropylene
• Supply & Exhaust Blower Motor: 1 PSC Motor
15.375" x 7.125" x 0.75"
- Protection type: Thermally protected
(39 cm x 18 cm x 1.9 cm)
- Insulation class: B
Project:
Location:
Part Number: 47110
Quantity:
Submitted by:
• Heat Recovery Core:
• Unit Electrical Characteristics:
120 volts, 60 Hz, 2.1 amps, 195 watts
REMARKS
Date:
Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715
www.venmar.ca
HRVConstructo2.0ESd151013
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement