MiniMax Pentair MiniMax Plus Electronic Ignition : instruction des branchements (Anglais)

Add to my manuals
1 Pages

advertisement

MiniMax Pentair MiniMax Plus Electronic Ignition : instruction des branchements (Anglais) | Manualzz

MiniMax Plus Electronic Ignition Wiring Instructions

EXTERNAL

BOND LUG

RED

WHT/RED

WHT/BLK

BLK

TERMINATE SUPPLY SAFETY GROUND WIRE (GREEN) HERE

GROUND SCREW WITH PAINT CUTTING WASHER

CHASSIS

SHEET METAL

T1

GRN

L2-1

CHASSIS

SHEET METAL

L1-1

HIGH LIMIT

THERMAL SWITCHES

L1-2

W1

RED

L2-2

WHT

WATER PRESSURE

SWITCH

WHT

W2

MiniMax Plus WIRING DIAGRAM

IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY

UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 105 C TEMPERATURE RATING.

THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED

WIRE, 18 GAUGE, 600V, 125 C TEMPERATURE RATING..

INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL

CODE OR SUPERCEDING LOCAL (WIRING) CODES.

RED

THERMAL FUSE

F1 F2

RED

WHT

BLU

MV

PV/MV

PV

IGNITION RETURN

GRN

GAS VALVE

MV

PV/MV

PV

IGNITION MODULE

T2

WHT

ORG

RED

WHT

BLU

MV

MV/PV

PV

SPST. EXTERNAL ON/OFF SWITCH

P4 P7

PI0 P11

ORG

GRN

MV

MV/PV

PV

GND

(BURNER)

GND

24 V

TH-W

( OPT )

SPARK

JUMPER REQUIRED IF NO REMOTE SWITCH

25D K .032 D.C TAB

J2 J3

24V

J4

1 1

J7

VLV

JI0

1

IGN MODULE

J11

1

IGNITION WIRE

AUX.

CONTACTS

CONTROL RELAY

CLOSE ON CALL

FOR HEAT

TPROBE

J6

SPA

P6

J8

COM

P8

J5

POOL

P5

J9

P9

THERMOSTAT

CIRCUIT BOARD

SPARK IGNITER

2 Wire Remote

BLK

BLK

TEMPERATURE

PROBE

POOL OFF SPA

THERMOSTAT SELECT SWITCH

REMOTE SWITCH DUAL THERM IID ONLY

OUT

JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH

24 VAC PRESS HILMT TFUSE

RETURN

VALVE IGNITION MOD

THERMOSTAT CIRCUIT BOARD

SPA COM POOL TPROBE

NOTE: When connecting a remote control to the MiniMax

Plus, you must install the low voltage thermostat wires in separate conduit from ANY line voltage wires. Failure to follow these instructions will cause the thermostat relay to react erratically.

.

3 Wire Remote

FRONT PANEL

POOL/OFF/SPA

THERMOSTAT SELECT SWITCH

OUT

JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH

24 VAC PRESS HILMT TFUSE

RETURN

VALVE IGNITION MOD

THERMOSTAT CIRCUIT BOARD

SPA COM POOL TPROBE

REMOTE POOL/OFF/SPA

THERMOSTAT SELECT SWITCH

FRONT PANEL

POOL/

OFF/SPA

THERMOSTAT SELECT SWITCH

Rev. B 1-23-01 P/N 470191