MiniMax Plus Electronic Ignition Wiring Instructions
EXTERNAL
BOND LUG
RED
WHT/RED
WHT/BLK
BLK
TERMINATE SUPPLY SAFETY GROUND WIRE (GREEN) HERE
GROUND SCREW WITH PAINT CUTTING WASHER
CHASSIS
SHEET METAL
T1
GRN
L2-1
CHASSIS
SHEET METAL
L1-1
HIGH LIMIT
THERMAL SWITCHES
L1-2
W1
RED
L2-2
WHT
WATER PRESSURE
SWITCH
WHT
W2
MiniMax Plus WIRING DIAGRAM
IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY
UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 105 C TEMPERATURE RATING.
THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED
WIRE, 18 GAUGE, 600V, 125 C TEMPERATURE RATING..
INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL
CODE OR SUPERCEDING LOCAL (WIRING) CODES.
RED
THERMAL FUSE
F1 F2
RED
WHT
BLU
MV
PV/MV
PV
IGNITION RETURN
GRN
GAS VALVE
MV
PV/MV
PV
IGNITION MODULE
T2
WHT
ORG
RED
WHT
BLU
MV
MV/PV
PV
SPST. EXTERNAL ON/OFF SWITCH
P4 P7
PI0 P11
ORG
GRN
MV
MV/PV
PV
GND
(BURNER)
GND
24 V
TH-W
( OPT )
SPARK
JUMPER REQUIRED IF NO REMOTE SWITCH
25D K .032 D.C TAB
J2 J3
24V
J4
1 1
J7
VLV
JI0
1
IGN MODULE
J11
1
IGNITION WIRE
AUX.
CONTACTS
CONTROL RELAY
CLOSE ON CALL
FOR HEAT
TPROBE
J6
SPA
P6
J8
COM
P8
J5
POOL
P5
J9
P9
THERMOSTAT
CIRCUIT BOARD
SPARK IGNITER
2 Wire Remote
BLK
BLK
TEMPERATURE
PROBE
POOL OFF SPA
THERMOSTAT SELECT SWITCH
REMOTE SWITCH DUAL THERM IID ONLY
OUT
JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH
24 VAC PRESS HILMT TFUSE
RETURN
VALVE IGNITION MOD
THERMOSTAT CIRCUIT BOARD
SPA COM POOL TPROBE
NOTE: When connecting a remote control to the MiniMax
Plus, you must install the low voltage thermostat wires in separate conduit from ANY line voltage wires. Failure to follow these instructions will cause the thermostat relay to react erratically.
.
3 Wire Remote
FRONT PANEL
POOL/OFF/SPA
THERMOSTAT SELECT SWITCH
OUT
JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH
24 VAC PRESS HILMT TFUSE
RETURN
VALVE IGNITION MOD
THERMOSTAT CIRCUIT BOARD
SPA COM POOL TPROBE
REMOTE POOL/OFF/SPA
THERMOSTAT SELECT SWITCH
FRONT PANEL
POOL/
OFF/SPA
THERMOSTAT SELECT SWITCH
Rev. B 1-23-01 P/N 470191