General catalogue Panasonic PACi 2015 EN

General catalogue Panasonic PACi 2015 EN
NEW COMMERCIAL RANGE
EXTREMELY
EFFICIENT
2015 — 2016
PACi STANDARD - PACi ELITE
NEW COMMERCIAL AIR TO AIR 2015 - 2016
NEW 2015 / 2016
COMMERCIAL RANGE
Summary
PANASONIC, THE AIR OF YOUR LIFE ..............................................................................................................................4
RELIABILITY FACTS.......................................................................................................................................................6
PANASONIC NO. 1 ........................................................................................................................................................8
PANASONIC – LEADING THE WAY IN HEATING AND COOLING.........................................................................................10
PRO CLUB .................................................................................................................................................................12
WELCOME TO THE COMMERCIAL RANGE......................................................................................................................14
HIGHLIGHTED FEATURES ............................................................................................................................................16
PACi STANDARD AND ELITE ........................................................................................................................................18
PACi ELITE OUTDOOR UNITS .......................................................................................................................................20
SOLUTIONS FOR SERVER ROOMS................................................................................................................................22
PACi STANDARD AND ELITE: INDOOR UNITS.................................................................................................................24
RANGE OF COMMERCIAL UNITS ..................................................................................................................................28
WALL MOUNTED PKEA................................................................................................................................................30
WALL MOUNTED PACi STANDARD AND ELITE INVERTER+ .............................................................................................32
4 WAY 60x60 CASSETTE PACi STANDARD AND ELITE INVERTER+...................................................................................34
4 WAY 90x90 CASSETTE PACi STANDARD AND ELITE INVERTER+...................................................................................36
LOW STATIC PRESSURE HIDE AWAY PACi STANDARD AND ELITE INVERTER+ .................................................................38
HIGH STATIC PRESSURE HIDE AWAY PACi STANDARD AND ELITE INVERTER+.................................................................40
CEILING PACi STANDARD AND ELITE INVERTER+..........................................................................................................42
HIGH STATIC PRESSURE HIDE AWAY 20-25 kW BIG PACi INVERTER+ ............................................................................44
PACi TWIN, TRIPLE AND DOUBLE-TWIN SYSTEM ..........................................................................................................46
ELECTRIC AIR CURTAIN ..............................................................................................................................................50
AIR CURTAIN WITH DX COIL ........................................................................................................................................52
AIR HANDLING UNIT KIT 10-25 kW FOR PACi ...............................................................................................................56
R22 RENEWAL ...........................................................................................................................................................58
CONTROL EQUIPMENT EXTERNAL DIMENSIONS ...........................................................................................................61
PKEA DIMENSIONS ....................................................................................................................................................62
PACi STANDARD AND ELITE DIMENSIONS ....................................................................................................................63
CONTROL AND CONNECTIVITY ............................................................................................................ 72
PANASONIC SMART CLOUD .........................................................................................................................................74
REMOTE CONTROLLER WITH ECONAVI .........................................................................................................................76
ECONAVI SENSOR ......................................................................................................................................................78
CONTROL SYSTEMS FOR PACi, ECOi AND ECO G ...........................................................................................................81
CONTROL FOR HOTEL APPLICATION ............................................................................................................................82
INDIVIDUAL CONTROL SYSTEMS..................................................................................................................................84
CENTRALISED CONTROL SYSTEMS ..............................................................................................................................86
PACi AND VRF CONTROL.............................................................................................................................................93
INTERNET CONTROL ...................................................................................................................................................93
PACi AND VRF CONNECTIVITY .....................................................................................................................................94
PACi CONNECTIVITY ...................................................................................................................................................94
ECOi AND GHP CONNECTIVITY.....................................................................................................................................95
ECOi, ECO G AND PACi CONNECTIVITY INDOOR UNITS...................................................................................................96
Quality Management System Certificate
2
Environmental Management System Certificate
Certified to ISO 9001: 2008
Certified to ISO 14001: 2004
Panasonic Appliances Air-Conditioning
Malaysia. Sdn.Bhd.
Cert. No.: MY-AR 1010
Panasonic Appliances Air-Conditioning
Malaysia Sdn.Bhd.
Cert. No.: MY-ER0112
Certified to ISO 9001: 2008
Certified to ISO 14001: 2004
Panasonic Appliances Air-Conditioning
(GuangZhou) Co., Ltd.
Registration Number: 01209Q20645R5L
Panasonic Appliances Air-Conditioning
(GuangZhou) Co., Ltd.
Registration Number: 02110E10562R4L
NEW 2015 __ 2016
Commercial Range Highlights
Big PACi Hide Away 20-25 kW
New big capacity ducts with DC fans.
High efficiency and only from 38dB(A) operation.
Econavi
Econavi for PACi is more than just a sensor. It also analyse occupancy and
activity level adjusting operation for improve comfort and reduce energy.
Compatible with any PACi and ECOi.
Elite TOP features
SEASONAL
EFFICIENCY
SEER — SCOP
Outstanding performance at low temperatures, high energy efficiency,
power consumption in remocon display.
A++
A+
Server room solutions
Choose the best solution to ensure any server room needs. Designed for
high durability and adverse weather conditions its server room ad hoc
control essure permanent operation and failure alarms communications.
Complete AHU Solution
Demand control 0-10V, box IP65 case, cold draft prevention, monitoring
status digital output, remote control built-in.
Easy
Control and connectivity
control
by BMS
CONNECTIVITY
Control your units from anywhere with the Wifi adapter or Integrate to any
BMS protocol: KNX, Modbus or BACnet.
R22 replacement
R22 Renewal. All Panasonic units can be install on existing R22 pipings.
Possible
to use on
R22
R22 pipings
R22 RENEWAL
3
Panasonic,
e
f
i
L
r
u
o
y
f
o
r
i
A
the
Since 1958
Panasonic, the Air of your Life
Panasonic Air Conditioners have been with us since 1958. In many homes they are
part of the family and are, in part, responsible for the air that each member breathes.
Many things happen in your home, and Panasonic makes sure that those moments have the best climate.
Panasonic Air Conditioners were the first to produce Healthy Air, and also worry about being super-efficient and
quiet. Which is why they have been among us for so long.
1973
1958
First room air conditioner launched for
domestic installation.
4
Panasonic launches the first
highly efficient air-to-water
heat pump in Japan.
1975
Panasonic becomes the first
Japanese air conditioner
manufacturer in Europe.
2008
Etherea new concept of
air conditioning systems:
high efficiency and high
performances with a great
design.
NEW __ EDITORIAL
No.1
in Japan
40 years
in Europe
History of Air Conditioning Group
Panasonic starts with a desire to create things of value. As hard work and
dedication results in one innovative product after another, the fledgling company
takes its first steps towards becoming the electronics giant of today.
2010
New Aquarea.
Panasonic has created
Aquarea, an innovative new,
low-energy system.
2011
The new Panasonic ECOi VRF
solution for big buildings
is the most efficient in the
industry in more than 74% of
combinations.
2012
Looking ahead
New GHP units. Pansonic’s
gas-driven VRF systems are
ideal for projects where power
restrictions apply.
By creating, storing, managing and
saving energy, Panasonic aims to
realize a lifestyle with virtually zero CO2
emissions throughout the entire home.
Heating and Cooling Solutions designed and produced by Panasonic since 1958. See more information on www.aircon.panasonic.eu
5
Reliability facts
Reliable comfort comes from reliable technologies
Today, Panasonic air conditioners have earned widespread acclaim throughout the world. A rugged design ensures
that the air conditioner will continue to keep the room comfortable, and operate trouble-free for many years.
Panasonic believes this is the true value of an air conditioner. And this is why we subject them to a wide range of
stringent tests.
Durability. Long Time Continuous Operation Simulation.
Long-term Durability Test
The air conditioner’s main mission is to provide a level
of durability that allows it to operate stably for years. In
order to achieve this, we conduct an accelerated test
for 10,000 hours of continuous operation. The results of
this test, which is conducted under conditions that are
much more severe than actual operating conditions,
prove the rugged strength of Panasonic air conditioners.
Compressor Disassembly Test
After a test with 10,000 hours of continuous operation,
we remove the compressor from a randomly selected
outdoor unit, disassemble it, then examine the internal
mechanisms and parts for possible failure. Panasonic
air conditioners continue to provide their designed
performance for many years even after prolonged
operation under harsh conditions.
Operating Test in Harsh Conditions
In addition to normal operating conditions, an operating
durability test is conducted in a high-temperature, high
humidity test chamber at a temperature of 55°C. For
use in cold climates, the test is also conducted in a low
temperature test chamber at -20°C. This test assures
that the oil inside the compressor will not freeze during
use and interrupt operation.
Checking the oil inside the
compressor under
extremely cold conditions.
6
Waterproof Test
The outdoor unit, which is subject to rain and wind, is
provided with IPX4 waterproof compliance.
Contact sections on printed circuit boards are also
resin-potted to prevent adverse effects caused by an
unlikely exposure to droplets of water.
A resin-potted circuit board.
NEW __ EDITORIAL
No Breaking. When Dropped onto Sides or Corners.
Shock Resistance
Panasonic simulates impacts, vibrations and other
environmental conditions that air conditioners might be
subjected to during transport. We promise that the quality
and performance at the time of the final product inspection
are unchanged when the product reaches the user’s home.
Drop Test
Even with the large impacts that may occur due to improper handling during
transportation, the product packaging has been strengthened to prevent it
from being damaged. In addition to conventional vertical dropping, more
severe conditions in which the sides or corners hit the floor first are carefully
tested to ensure that the product’s rigidity and shock-absorbing materials
work to prevent problems.
Vibration Test
Preventing damage that would
hinder the product’s performance
due to vibration during transport is
a major role of the packaging.
Panasonic confirms that the
product operates properly even
after applying vibrations in both
horizontal and vertical directions.
Warehouse Storage Test
During distribution, products may
be subjected to extended
warehouse storage under
unfavourable conditions. To
simulate these conditions, we
place a weight equal to a stack of
five product packages on top of the
test package, and leave it in that
condition in a room at a
temperature of 27°C and a
humidity level of 85%. Then, the
product is checked for proper
operation.
EMC (Electromagnetic
Compatibility) Test
This test determines whether
electromagnetic waves emitted
during operation are sufficiently
low to prevent adverse effects, i.e.,
electrical noise, on signals such as
TV and radio broadcasts.
Remote Control Dropping Test
Because the remote control is the
main interface between people and
the air conditioner, it is naturally
subjected to frequent impacts such as drops and bumps - when it
is passed from person to person
during normal operation. Panasonic
drops the remote control from a
height of 1.5 metres at various
angles to ensure that no problems
in basic performance will result
from accidental dropping.
Silence. That Does Not Disturb You.
Comfort
Air conditioners should keep each person in the room
comfortable without making their presence known.
They should work totally in the background, using their
strength to create and maintain a relaxing environment. We
build this hidden strength into our air conditioners, and test
them repeatedly from this viewpoint.
Noise Test
The operating noise of the indoor
and outdoor units is measured in
an echo-free chamber. The noise
test verifies that the operating
noise is low enough so that the
product operation will not disturb
daily activities including
conversations and sleep.
Sunshine simulation.
Amenity Test
An actual air conditioner is
operated in a test room that
simulates an ordinary living room.
Conditions such as the amount of
sunlight entering the room from
outside are changed while
measuring a variety of parameters,
such as cooling speed, cooling
efficiency, and temperature and
humidity differences throughout the
room. This makes it possible to
confirm whether the air conditioner
is operating at its designed
performance level under ordinary
conditions.
Quality. Is at the Core of All Our Manufacturing.
World Standard Quality
Over the years, Panasonic air conditioners have continued to
offer the highest possible quality with the lowest
environmental impact worldwide. Naturally, the fundamental
production principles that are common to all Panasonic
products apply to air conditioners as well. The fact that these
principles actively support every product, rather than simply
serving as slogans, is the result of the endless repetition of
challenges and trial-and-error efforts that are conducted at
our production bases all over the world.
Reliable Parts with Major
Standards Approval
Panasonic air conditioners comply
with all of the major standards that
maintain high reliability in the
countries and regions where they
are marketed. To ensure this, we
conduct a variety of tests to
examine the quality of materials
used in parts.
The strength of the
resin material used in
the propeller fan is
confirmed by the
tension test.
RoHS/REACH Compliant Parts
All parts and materials comply with
RoHS/REACH, Europe’s worldleading environmental regulations.
Stringent inspections of more than
100 materials are conducted to
ensure that no hazardous
substances are included during
parts development.
Sophisticated Production
Process
The air conditioner production line
uses advanced, state-of-the-art
factory automation technologies to
produce products with higher
reliability. Products are efficiently
manufactured with high and
uniform quality.
Eco Activities
Panasonic has set up eco ideas
factories around the globe. While
developing and manufacturing
energy-saving products based on
original environmental
technologies, these factories
reduce CO2 emissions from
manufacturing processes and
conduct regional-based
environmental communication
activities to contribute to both the
global environment and the local
communities that they serve.
7
Panasonic No. 1
Interbrand Ranks Panasonic No. 1 in the Electronics Sector for the “Best
Global Green Brands 2014”
Interbrand, the US brand consulting company, announced on June 24, 2014, that Panasonic ranks No.
5 in its Best Global Green Brands 2014. Although a rank lower than last year, the company has come
out top in the electronics sector.
2014 marks the fourth year for this global ranking of “green brands.” An Excellent Green Brand is
defined as achieving a good balance between Green Perception (consumers’ image of an eco-brand)
and Green Performance (a company’s environmental management practices). The top 50 companies
are ranked based on these two elements.
Evaluation Points
Panasonic’s Green Performance was evaluated as being especially high, with excellent marks going to
“Products and Services,” “Governance,” and “Transportation and Logistics.”
Interbrand also noted the following points in its evaluation
Energy Star Award Recognitions: Panasonic has received more Energy Star awards than any other
consumer electronics manufacturer.
Achieved a Recycling Rate of 99.3%: Taking steps toward zero waste, Panasonic achieved a
factory waste recycling rate of 99.3% in 2013.
Improved Water Usage: In 2013, water usage at factories per basic unit of production improved by
0.7% compared with 2012.
Econavi Function: In 2009, Panasonic launched home appliances with the Econavi function, which
automatically controls power and water consumption to cut losses by using sensor and other energy
efficient technologies.
8
NEW __ EDITORIAL
We aim to realize a lifestyle
with virtually zero CO2 emissions
throughout the entire home
By creating, storing, managing and saving
energy, Panasonic aims to realise a lifestyle
with virtually zero CO2 emissions throughout the
entire home.
Solar Power Generator
HIT solar cells achieve
maximum output even on
smaller roofs. These solar
modules are 100% emission
free, have no moving parts
and produce no noise.
Home AV
Panasonic offers a wide
range of energy saving home
equipment to fulfil a
sustainable and comfortable
lifestyle.
Heat Pump
The Aquarea Heat Pump is
part of a new generation of
heating systems that use a
renewable, free energy
source: air, to heat or cool
the home and to produce hot
water.
Fuel Cell
The Panasonic Fuel Cell is an
energy-creating device, which
generates electricity and heat at
the same time with chemical
reaction between hydrogen
extracted from natural gas and
oxygen.
Solar Power Generator
Our mobility space can be
connected to our HIT solar
panels – with help of our
storage batteries.
LED Lamps
Expertise gathered over years of
research and development has
enabled Panasonic to provide a
renaissance in energysaving home
LED lighting – with our LED
Nostalgic Clear lamp.
Home Appliances
Panasonic is globally committed to
develop products which are
environmentally friendly. Panasonic
delivers home appliances such as
refrigerators and washing machines
that incorporate the latest energyefficient technology.
Storage Battery
The battery stores the energy
generated by a combination of
solar power and fuel cells to
ensure a constant supply of
electricity on demand.
Exemplary sustainable projects
What is Smart Electric Lyon?
Smart Electric Lyon is a project that looks at
electricity consumption as a key part of the
building energy solutions of tomorrow.
This experiment, will be conducted for four
years in more than 25,000 homes, businesses
and communities of Grand Lyon.
Panasonic will provide the project with a variety
of its energy efficient heating and cooling
products, including the Aquarea Air Source Heat
Pump. These heat pumps are especially
equipped with connectivity solutions from
Panasonic to ensure the systems are easy to
use, and collect the vital, accurate data.
This project is particularly apt for Panasonic, as
heating and hot water occupy a prominent place
in household energy consumption. The company
has involved for the project a dedicated and
experienced R&D team from Panasonic’s
European technical centre in Frankfurt.
Fujisawa Sustainable Smart Town Goes Into
Full-Scale Operation Near Tokyo
Fujisawa SST Council, a consortium led by
Panasonic Corporation spearheading the
development of the Fujisawa Sustainable Smart
Town (Fujisawa SST). With its core facility
supporting sustainable development of the town
and its community now coming into operation,
the Fujisawa SST is moving from the
construction stage into a new stage where the
town is nurtured to grow in full-scale into an
eco and smart town that puts a high priority on
the residents’ lifestyles.
The Fujisawa SST Management Company is the
town management company located in the
SQUARE. Together with partner companies, the
company provides five essential services in the
town: energy, security, mobility, healthcare and
community. The company will also collect and
manage information pertaining to the town’s
overall environment, energy, security and safety
to support an eco and smart life in the town.
As a fresh development in the town, the Fujisawa
SST has set a detached housing zone for non car
owners for the second phase of sales. By using
the town’s eco-car sharing and rent-a-car
services, residents in the zone can enjoy their
lifestyles without the need to own a car while
reducing economic burden and making effective
use of the lot. Preparations are also underway for
a new base to provide environmentally-friendly
logistic services to the residents.
9
Panasonic – leading the way in
Heating and Cooling
With more than 30 years of experience, selling to more than 120 countries around the world,
Panasonic is unquestionably one of the leaders in the heating and cooling sector.
With a diverse network of production and R&D facilities, Panasonic delivers innovative products
incorporating cutting-edge technologies that set the standard for air conditioners worldwide.
Expanding globally, Panasonic provides superior international products transcending borders.
100% Panasonic: we control the process
The company is also a world leader in innovation as it has filed more than 91,539 patents to improve
its customers’ lives. Moreover, Panasonic is determined to remain at the forefront of its market. In
all, the company has produced more than 200 million compressors and its products are manufactured
in 294 plants which are located all over the world. You can be assured of the extremely high quality of
Panasonic’s heat pumps.
This wish to excel has made Panasonic the international leader in heating and turn-key air
conditioning solutions. These offer maximum effectiveness, comply with the strictest environmental
standards and meet the most avant-garde construction requirements of our time.
10
NEW __ EDITORIAL
Projects & Case Studies of Panasonic Heating and Cooling Solutions
Call centre retrofit. Woodhouse
Environmental Services Ltd. Bourmemouth,
UK. VRF
New residential building. 84 apartments.
Barcelona, Spain. Aquarea
New condominium. Bergås Terasse
complex. Drammen, Norway. ECOi /
Aquarea
Hotel refurbishment. Hotel Claris 5 *
Barcelona, Spain. ECOi
New residential building. 176 flats
Xàtiva, Spain. ECO G
French Winery. Boutiers-Saint-Trojan,
France. ECO G
Le Centurie Centro Commerciale. 40,000 m²
with 40 commercial spaces. Padua, Italy.
ECOi
Europa-Park is the second most popular
theme park resort. 300 rooms. Germany.
ECOi
The National Grid’s. Call Center
refurbishment. Hinkley, UK. ECO G
The exclusive Sunprime Atlantic View
resort, owned by Thomas Cook. 220 rooms.
Canary Islands. Spain. ECO G
Montcenis Nursing Home. Over 6100 m2
and 85 rooms. Saône et Loire, France.
ECO-G
Smart House. Ariake, Tokyo. HVAC and the
combination of solar power generation,
fuel cells and storage batteries.
Technopark of Nobosibirsk Academgorodok.
Novosibirsk, Russia. ECOi
Shippensburg University. Pennsylvania,
United States. ECOi
Urban residential Mosaic Panama Pacifico.
Republic of Panama. Mini ECOi
Patra Jasa Bandung Hotel. Bandung,
Indonesia. ECOi
To find out more: www.aircon.panasonic.eu
11
PRO Club
the professional website of Panasonic
Panasonic has an impressive range of support services for
designers, specifiers, engineers and distributors working in the
heating and cooling markets.
Panasonic PRO Club (www.panasonicproclub.com) is the online tool which
makes your life easier! You just have to register and a lot of functionalities
are freely available to you, where ever you are, from your computer or
smart phone!
· Print catalogues with your logo and your address
· Download the latest Aquarea designer to define your system and
select the good Aquarea Heat pump.
· Calculate the specs of the Aquarea Air fan coil based on the
parameters of your system
· Get Documents of conformity and all other documents you may
need
· Download all the service manuals, end user manuals and
installation manuals
· Know what to do with error codes
· Find out about the latest news first
· Register for training
12
Highlighted Features
· Extensive library of resources
· Tools & Apps for end users. Check availability in your country:
- My Home: sizing wizard for domestic and A2W range
- My Project: Contact form to Panasonic team
- iFinder: Lists of installers displayed by postcode
· Special offers & promotions
· Training PRO Academy
· Catalogues (Commercial documentation)
· Marketing (Images in high resolution, advertisements, deco guidelines)
· Tools (Professional software, sizing tools...)
NEW Highlighted Features
· NEW! Installers customize leaflets in PDF format with their logo &
contact details
· NEW! Energy label generator. Download energy labels of any device in PDF
format
· NEW! Heating calculator demand
· NEW! Noise calculator for outdoor unit
· NEW! Aquarea Radiator calculator
· NEW! Error Code Search by error code or unit ref. Compatible with
smartphone and tablet computer
· NEW! Revit / CAD Images / Spec texts
· NEW! Access to Pananet, online library of technical documentation
· NEW! Download Documents of Conformity and other Certifications
· NEW! Commissioning online
NEW __ EDITORIAL
NEW! Easy download Panasonic service documentation and brochures
Panasonic PRO Club is fully compatible with tablet computer and
smartphone
NEW! Customize leaflets with your logo & contact details. Save and print the PDF
NEW! Energy label generator. Download Energy labels of any device in PDF format
NEW! Error Code on your smartphone and your PC: Search by error code or model
reference. Online version + downloadable version for offline use
The Panasonic PRO Academy
Panasonic takes its responsibility to its distributors, specifiers and
installers seriously and has developed a comprehensive Training
Programme. The Panasonic Pro-Academy encompasses the traditional
hands-on approach.
New training courses cover three levels. Design, installation, and
commissioning & trouble-shooting. Training courses include:
· Domestic applications Air to Air
· Aquarea air source heat pumps
· VRF ECOi
The courses are offered on site at Panasonic’s premises across Europe as
well as via the Panasonic ProClub eLearning site. The Training Centres
display Panasonic’s latest product range and give delegates an opportunity
to get hands-on experience with the latest controllers, indoor and outdoor
units from the VRF ECOi, Etherea, GHP and Aquarea ranges.
www.panasonicproclub.com
or connect simply with your smartphone to the PRO Club using this QR
13
14
NEW __ COMMERCIAL
WELCOME TO THE COMMERCIAL RANGE
Here are some of your new air conditioner’s major features.
Panasonic has developed an impressive range of highly efficient Commercial Air Conditioners. This range confirms our
commitment to the environment. Our Inverter compressors optimise performance and thus reduce energy costs.
15
Highlighted Features
PACi Standard: For economy and value
With high quality design and engineering, the PACi Standard is the perfect solution for projects which
demand quality on a limited budget. In addition, its compact size and light weight make it ideal for
installations with limited space including small commercial and residential applications.
PACi Elite: Newly designed next generation of commercial air conditioning
Energy-saving concept. The use of energy saving design for the structure of fans, fan motors,
compressors and heat exchangers resulted in high COP value which ranked as one the top class in
the industry. In addition, use of highly efficient R410A refrigerant reduces CO2 emission and lowers
operating costs.
16
NEW __ COMMERCIAL
Internet
Energy
Up to 28%
energy savings
(cooling)
TI
O
N
AL
saving
OP
PROFESSIONAL
SMART CLOUD
Control
Ready
INTERNET CONTROL
The new Cloud system from
Panasonic allows you to have
complete control of all your
installations. In a simple
click, all your units from
several locations, receive
status updates in real-time of
all your installations,
preventing breakdowns and
optimizing costs.
6,80 A++
SEER
SEASONAL ENERGY
EFFICIENCY RATIO
Exceptional Seasonal Cooling
Efficiency based on the new
ErP regulation.
Higher SEER ratings mean
greater efficiency. Save all the
year while cooling!
Environmentally
friendly
Internet Control is a next
generation system providing a
user-friendly remote control
of air conditioning or heat
pump units from everywhere,
using a simple Android or iOS
smartphone, tablet or PC via
internet.
4,00 A+
SCOP*
SEASONAL COEFFICIENT
OF PERFORMANCE
Exceptional Seasonal Heating
Efficiency based on the new
ErP regulation.
Higher SCOP ratings mean
greater efficiency. Save all the
year while heating!
Possible
to use on
refrigerant
R22 pipings
R410A
R22 RENEWAL
R410A. Environmentally
friendly refrigerant.
The Panasonic renewal
system allows good quality
existing R22 pipe work to be
re-used whilst installing new
high efficiency R410A
systems.
Inverter plus products improve
on the characteristics of
standard Inverter range by
over 20%. This means 20%
less consumption and 20% off
your electric bill. A Inverter
plus is also A class on cooling
and heating mode.
Econavi features intelligent Human Activity
Sensor and new Sunlight Sensor technologies
that can detect and reduce waste by
optimising air conditioner operation according
to room conditions. With just one touch of a
button, you can save energy efficiently with
uninterrupted cooling, comfort and
convenience.
Easy
Down to
-15°C in
cooling mode
Down to
-20°C in
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
The air conditioner works in
cooling only mode with an
outdoor temperature of -15°C.
The air conditioner works in
heat pump mode even when
outdoor temperatures are as
low as -20°C or -15°C.
The communication port is
integrated into the indoor unit
and provides easy connection
to, and control of, your
Panasonic heat pump to your
home or building management
system.
5 year
compressor
warranty
5 Years Warranty.
We guarantee the
compressors in the entire
range for five years.
17
Energy
saving
PACi Standard and Elite
PACi Standard
· Good balance, system cost vs energy efficiency
· Top class SEER/SCOP as a Standard Inverter category
SEER: A++ / SCOP: A+ at 10.0 kW (in Cassette 90x90)
· Interchangeable controller with ECOi
· Compact outdoor units
· Twin connection possible
· Cooling operation up to -15°C
· Heating operation up to -10°C
PACi Elite
· Meeting all necessary safety approvals to ensure quality and safety
· Top-class SEER: A++ / SCOP: A+ at 10.0 kW (in Cassette 90x90 and Ceiling)
· Cooling operation is possible when outdoor temperature as high as 46°C
· DC inverter technology combined with R410A for excellent efficiency
· Cooling operation is possible when outdoor temperature as low as -15°C
· Heating operation is possible when outdoor temperature as low as -20°C
· Compact outdoor units
· Auto restart from outdoor unit
· Twin, Triple and Doble-Twin connection possible
18
NEW __ COMMERCIAL
SEASONAL
EFFICIENCY
SEER — SCOP
SEASONAL
EFFICIENCY
SEER — SCOP
A++
A++
A+
A+
PACi Standard: outdoor unit
More compact
The outdoor unit is much more compact than the previous model. The slim
and lightweight design means the PACi outdoor unit can be installed in a
number of situations.
* Only for U-100PEY1E8, U-125PEY1E8,
U-100PEY1E5 and U-125PEY1E5.
Product Quality and Safety
All Panasonic air conditioners undergo strict quality and safety tests before
sale. This rigorous process includes obtaining all necessary safety
approvals, to ensure that all air conditioners we sell are not only built to
the highest market standards, but are also completely safe.
Old models (1.170 x 900 x 320)
Quiet mode
2, 4 or 6 dB can be reduced by different setting on your choice. External
input signal is also available.
-15%
SMALLER
On the 12,5 kW (996 x 940 x 340)
19
PACi Elite outdoor units
Improved energy saving
Operating efficiency has been improved using highly efficient R410A refrigerant, new DC inverter
compressor, new DC motor and a new heat exchanger design.
4,50
4,31
4,20
4,00
4,00
3,86
3,86
3,70
3,61
3,60
3,50
3,43
3,41
3,25
3,00
3,01
2,50
10,0 kW
12,5 kW
14,0 kW
11,2 kW
New model
14,0kW
16,0 kW
Current model
Wide operating range
· Cooling operation is possible when outdoor temperature as low as -15°C
· Cooling operation is possible when outdoor temperature as high as 46°C
· Heating operation is possible when outdoor temperature as low as -20°C
The remote control temperature setting offers a range from 18°C to 30°C.
Cooling: -15°C DB / 46°C DB
Heating: -20°C WB / 24°C WB
-20
20
-15
-10
-5
0
5
10
15
20
25
30
35
40
46
50
NEW __ COMMERCIAL
Energy saving concept
The use of energy saving designs for the structure of fans, fan motors,
compressors and heat exchanges has resulted in a high COP value, ranked
as one of the top classed in the industry. In addition, use of highly efficient
R410A refrigerant reduces CO2 emission and lowers operating costs.
5
3
1. Compact & highly efficient compressor. Large-capacity inverter compressor has been
adopted. The inverter compressor is superior in performance with improved partial-load
capacity.
2. Printed circuit board (P-LINK). To improve maintenance, the number of PCBs have been
reduced to two.
3. DC fan motor. Considering load and outside temperature, the DC motor is controlled for
optimum air volume.
4. New large diagonal (520 mm) air flow fan. The fan has been designed to reduce air
turbulence and increase efficiency. As fan diameter has been increased to 520 mm, the
air volume has been increased by 12% whilst maintaining a low sound level.
5. High-efficiency heat exchanger. The heat exchanger size and the copper tube sizes in the
heat exchanger have been redesigned to increase efficiency.
Excellent SEER and SCOP values
Panasonic have a extremely high SEER and SCOP values following the
SBEM method (some other manufacturers may use another non official
calculation method). Developed by BRE, SBEM (Simplified Building Energy
Model) is the basis of non-domestic building energy calculations. Based on
the National calculation method (NCM), it is used to determine compliance
with Part L of the Building Regulations and is also used to provide Energy
Performance Certification.
2
4
1
1. Compact & highly efficient compressor
2. Printed circuit board (P-LINK)
3. DC fan motor
4. New large diagonal (520 mm) air flow fan
5. High-efficiency heat exchanger
Increased Piping Length for Greater Design Flexibility
Adaptable to various building types and sizes.
Maximum piping length: 75m (10,0, 12,5, 14,0kW). 50m (6,0, 7,1kW).
Maximum total length: 75 m
Non-Domestic Building Services Compliance Guide provides information on various aspects of the calculation method, including
those of Heat Pumps (Section 3), and Comfort Cooling (Section 9).
SCOP - Seasonal Coefficient of Performance
Part Load COP
25%
Ambient conditions
15°C
Weighting factor
0,20 (a)
50%
7°C
0,36 (b)
75%
1°C
0,32 (c)
100%
-5°C
0,12 (d)
75%
30°C
0,32 (c)
100%
35°C
0,12 (d)
Maximum
height
difference
30 m
UK winter -5°C DB (outdoor temperature), 20°C WB (indoor temperature)
SEER - Seasonal Energy Efficiency Rating
Part Load COP
25%
Ambient conditions
20°C
Weighting factor
0,20 (a)
50%
25°C
0,36 (b)
* 15m if the outdoor unit
is below the indoor unit.
UK summer 21°C DB (outdoor temperature), 16°C WB (indoor temperature)
SEER calculation corresponds with below conditions and power input of indoor units is not included.
· Indoor temperature: 27°C DB / 19°C WB
· Outdoor temperature conditions
Part load ratio
Outdoor air temperature (°C DB)
Weighting coefficients
25%
20
0,23
50%
25
0,41
75%
30
0,33
100%
35
0,03
· Formula : 0,23 x EER25% + 0,41 x EER50% + 0,33 x EER75% + 0,03 x EER100%.
Compact & Flexible-design
The slim and lightweight design means the PACi outdoor unit can be
installed in a number of compact situations.
As the unit only weighs 98 kg, it is easy to carry and easy to install.
Single Split
Demand Response Compliant (CZ-CAPDC3)
This optional part allows demand control of the outdoor unit.
Several level of settings are available:
· Level-1, 2, 3 : 75 / 50 / 0 %
· Level-1, 2 can be set in 40 - 100% (40, 45, 50…95, 100: each 5%)
Outdoor unit
Demand controller
PACi
DRM1
DRM2
DRM3
CZ-CAPDC3
C
Terminal block
(supplied as optional kit)
Demand control terminal is available
to control 0-50-75% of capacities.
21
ERGY
· HIGH EN Y
C
EFFICIEN
ATION
R
E
P
O
7
/
· 24
Solutions for server rooms
High efficiency products for 24/7 applications
Panasonic has developed a complete range of solutions for server rooms which efficiently protect
your servers, keeping them at an appropriate temperature even when the outdoor temperature is
below -20°C.
SEASONAL
EFFICIENCY
SEER — SCOP
A++
A+
SEASONAL
EFFICIENCY
SEER — SCOP
A++
22
NEW __ COMMERCIAL
Key points
High durability for 24/7 operation
· From 2,5 kW to 5 kW with PKEA units
· From 5 kW to 25 kW with PACi units
· Backup function
· Redundancy function
· Alternative run function
· Error information by dry contact
· Operation even at -20°C outdoor temperature
· Excellent performance with excellent SEER
· Product design for 24/7 operation
Indoor Fan. Cross-Flow-Fan
· High durability rolling bearings, large size (␸105mm) fan
· High efficiency blade
· Random pitch blade (low sound)
Compressor
DC2P Panasonic original compressor, with high efficiency and reliability.
High efficiency all the year
On 24/7 operation, the performance of the air conditioning is a key factor.
When the efficiency is high, the return on investment of such units is
quickly reached.
8,0
7,0
7,1
6,9
6,7
6,0
6,6
6,3
6,6
6,0
5,0
4,0
4,4
4,1
4,2
3,9
3,9
3,9
3,9
3,0
2,0
1,0
0
2,8 kW
3,2 kW
4,5 kW
5,0 kW
5,0 kW
PKEA
SEER
6,0 kW
PACi Elite
7,1 kW
Why is the Panasonic R2 Rotary Compressor so efficient?
1. High Efficiency Motor The premium silicon steel motor meets industry
efficiency requirements.
2. Improved Lubrication of High
Volume Oil Pump The extended,
high volume oil pump in
conjunction with a larger capacity
oil reservoir provides superior
lubrication.
3
3. Accumulator has Larger Refrigerant
1
Capacity The larger accumulator
accommodates generous refrigerant
amounts needed in longer line
length installations.
2
SCOP
ROTARY
INVERTER COMPRESSOR
Interfaces to run 2 (for PKEA) or up to 3 (for PACi) units on Backup and alternative run
PAW-SERVER-PKEA for PKEA
The PAW-SERVER-PKEA server room interface manages redundancy and
backup of two PKEA units with two different selectable modes:
· Plug and play by embedded redundancy and backup algorithm (no
external signal needed. Further details please refer to operation manual)
· External (third party PLC) redundancy and backup management by dry
contact
All settings are possible without the need for a computer connection. A
special Energy Saving Mode is selectable by deep switch (available only in
plug and play mode). The level of remote control input prohibition can be
set when external management is by dry contact.
A
B
Cable maximum
length 3 meters
each CN-CNT
Output Alarm Signal
A unit
B unit
(2 x dry contact maximum 12V)
PAW-SERVER-PKEA
Input ON/OFF Signal
A unit
B unit
(2 x dry contact maximum 12V)
Input PCB Special Settings
1 x Connection port to PC
Jumper 2)
Enable ON OFF dry
contact (maximum 12V)
Standard
remote
control
T10
T10
MODE
1/2 SET 5
T10
2
4
3
0
1
PAW-PACR3
Alarm contact
Output Run Signal
A unit
B unit
(2 x dry contact maximum 12V)
Jumper 1)
Energy Saving Function
PAW-PACR3 for PACi and ECOi Range
PAW-PACR3, in combination with one PAW-T10V on each indoor unit, allows
the redundant operation of 2 (or 3) PAC-i or VRF indoor units.
All units will be operated by programmable turns in order to achieve the
same operating time (example turn every 8 hours with 24 hours).
If the room temperature exceeds a freely set value, the 2nd (or 3rd) unit
will be switched ON and an alarm will be activated.
In combination with 1x PAW-T10V on each indoor unit, 2 or 3 PACi of ECOi
can be programmed to run redundant.
Room thermostat
Display and Settings:
· Possible to select next unit manually
· Possible to reset operation
· LED display shows operation status of the 2 or 3 units
· Operation status output
· Alarm LED and alarm output
External contacts
· Temperature limit can be set
· Temperature hysteresis can be set
· Room temperature is displayed
· Time counter displayed
23
360º
air flow
PACi Standard and Elite: indoor units
360° Air Flow, 4 Way 90x90 Cassette PACi Standard and Elite
4 Way 90x90 Cassette. Wide & Comfortable Airflow
This proprietary design provides a wide and very comfortable airflow. The cassette’s wide-angle discharge outlets and
flaps are larger in the middle, featuring a shape that was selected based on geometrics and testing of actual
prototype units. Air coming out of the center of the discharge outlets travels farther. From the sides of each outlet,
where the openings are larger, airflow spreads out to reach the corners of the room. Air is discharged across a wide
area from the four sides of the unit. The curves on the room temperature distribution graph expand gently out
through 360° in a circle centered on the indoor unit.
Higher efficiency split fin.
Improved heat-transfer coefficient due to adoption of
high efficiently grooved heat exchanger tube.
New DC-Fan motor.
Optimum airflow is achieved by a new DC-fan motor with
independent control.
Individual flap control.
Flexible Air flow direction control by individual flap control is
possible. 4 Flaps can be controlled individually by setting on wired
timer remote controller. It can make more flexible Air-flow control
to be matched to several demands in a room.
High-efficient & Silent turbo Fan.
The newly developed larger fan chassis and optimised
design of the airflow path has resulted in increased air
volume and quieter performance.
360° Air Flow for improved comfort
By redesigning the air-outlet and flap, Soft & 3D air flow circulates whole space and provides even temperature
distribution in the room.
Current Model
360° Air Flow
Current Model
IT’S COLD
1 m above
the floor
25.0
Temp.
More even temperature
in the room.
Simulated condition: Floor area: 225 m². Ceiling height: 3 m, Unit 12.5 kW type.
24
360° Air Flow
IT’S HOT
BETTER COMFORT
NEW __ COMMERCIAL
Flexible 3D air-flow control
Comfort air flow control & proper energy use. Flexible Air flow direction
control by individual flap control:
· 4 Flaps can be controlled
Outlet A:
individually (by standard
Swing (only
upper)
wired remote controller*).
· Versatile air flow control to
Outlet B:
Fix to upper
cover a wide variety of
Outlet C:
demands.
Swing
Ample airflow: 36 m3/min
Industry’s highest in the 140 PU class.
* Pre-setting is required for this function at
System Test-run procedure.
Outlet D:
Fixed to Lower
High-Ceiling Installation (Up to 5 m for 100 PU
and higher models)
The units can be installed in rooms with high
ceilings, where they provide ample floor-level heating
in the winter. (See ceiling height guidelines below.)
High Ceiling (Factory settings)
Size 100, 125
and 140
Size 60 and 71
3,0 m
3,6 m
Industry’s
Top-Class
4-way discharge
high ceiling
settings²
4,5 m
3-way discharge
with the optional
air-blocking
4,7 m
materials
2-way discharge
with the optional
air-blocking
5m
materials
Ceiling height guidelines
Settings¹
Indoor unit: 60PU-71PU
Indoor unit: 100PU, 125PU, 140PU
4 - way discharge
Factory settings¹
3,0
3,6
High ceiling setting¹
3,3
3,9
High ceiling setting²
3,6
4,5
3 - way discharge (optional
air - blocking materials)
3,8
4,7
2 - way discharge (optional
air - blocking materials)²
4,2
5,0
1) When using the unit in a configuration other than the factory settings, it is necessary to make settings on site to increase airflow. 2) Use air-blocking materials (CZ-CFU2) to completely block two discharge outlets for 2-way airflow.
Easy Maintenance and Cleaning
The flap can be removed easily for washing with water.
Low-Profile 33,5 mm Panel
The square panel integrates seamlessly with the ceiling. Discharge outlets
close when the unit is stopped.
One of the industry’s thinnest panels
A suction grill enables to
make 90-degree turns.
Lighter and Slimmer, Easier Installation
A lightweight unit at 24 kg, the unit is also very slim with a height of only
256 mm, making installation possible even in narrow ceiling voids.
A Drain Height of Approx. 850 mm from the Ceiling Surface
The drain height can be increased by approximately 350 mm over the
conventional value by using a high-lift drain pump, and long horizontal
piping is possible.
Up to
Up to
Only
256 mm*
Protrusion of 33,5 mm
Dust Prevention
Wide direction air discharge by outlet design.
The Circle Flow Flap and re-designed air-outlet eliminate airflow along
recessed parts of the ceiling which reduces contamination. If air flows only
along these recessed parts, they will quickly become dirty. The new,
improved air outlet design therefore greatly reduces dirt accumulation.
Dirt collects on the ceiling
300 mm
850 mm
Drain Pump of about
850 mm from the
ceiling surface
Airflow of
conventional
models
Airflow image from the new model
* For 6,0kW / 7,1kW
25
PACi Standard and Elite: indoor units
New 4-Way 60x60 Cassette
Lighter and slimmer, easier installation
Lightweight and very slim which makes installation possible even in narrow
ceilings.
A drain height of approx. 850 mm from the ceiling surface
The drain height can be increased by approx. 350 mm over the conventional
value by using a high-lift drain pump, and long horizontal piping is
possible.
Significant reduction of power consumption by using highly
developed DC fan motors with variable speed, special heat
exchangers, etc.
Convenient cleaning. The flap can be removed easily for washing.
Closed discharge port
When the unit is turned OFF, the flap closes completely to prevent dust
getting into the unit and to keep the equipment clean.
Quiet operation
These units are among the quietest in the industry, making them ideal for
hotels and hospitals.
Smooth and durable design
The sleek, compact design ensures a discreet installation - even where
space is limited.
Piping outlet in three directions
With three options for pipe outlets-rear, right and left - installation is
made easy.
Wall Mounted
The unit’s compact design and flat face ensure discreet installation, even in
a small space.
Air distribution is altered depending
on the operational mode of the unit
F1
Washable front panel.
The indoor unit’s front panel can be easily removed and washed for troublefree cleaning.
26
F2
90º
F3
F4
F5
Heating: F1 to F5
Cooling: F1 to F3
NEW __ COMMERCIAL
Low Static Pressure Hide Away (PN Type)
High Static Pressure Hide Away (PF Type)
Ultra-slim profile: 250 mm height for all models.
250 mm
Discharge air temperature control
· Possible to reduce cold drafts at heating operation.
Standardized height of
290 mm for all models
Height standardization
enables easy and uniform
installation for models
with different capacities.
Cold Drafts Reduction at Heating
· Accurate temperature
measurement by E2 sensor to
reduce cold drafts at heating. Air intake sensor
Built-in Drain pump (DC
motor pump)
External electrical
equipment box makes
maintenance easy
P-link PCB
- Built-in filter
- Side removable filter
E2 sensor
Before spec-in, please consult with an authorized
Panasonic dealer.
The static pressure outside the unit can be increased up to 150 Pa.
System Example
An inspection port (450 mm x 450 mm or more) is required at the controlbox side of the indoor unit body.
Canvas duct
Rectangle duct
60
70 Pa
150 Pa
71
70 Pa
150 Pa
100
100 Pa
150 Pa
125
100 Pa
150 Pa
140
100 Pa
150 Pa
More powerful drain pump
Using a high-lift drain pump, drain piping can be elevated up to 785 mm
from the base of the unit.
Air inlet
The unit features air inlet on one side, air outlet on the other side. The air
inlet filter can be pulled out from the side of the unit and can be folded.
Easy access if through the maintenance opening.
Intake grille
Inspection port (450 x 450 mm or more)
Type
Standard
Maximum available setting
Ceiling
Further comfort improvement
The wide air discharge opening
expands the air flow to the left and
the right. The unpleasant feeling
caused when the air flow directly
hits the human body is prevented by
the “Draft prevention position”,
which changes the swing width, so
that the degree of comfort is
increased.
4m
When air inlet duct (field supplied) is connected on suction side, remove the
filter, frame and insulation materials on both sides of the unit. Connect the
duct on the suction side of the unit by using prepared holes on the unit.
Air outlet site
A rectangular duct flange for the air outlet is fitted as standard. Round
outlet flange kits are available as an optional accessory kit.
7m
Standard
F1
F2
60º
F3
F4
F5
Further comfort improvement
with airflow distribution
Heating: F1 to F5
Cooling: F1 to F3
Air distribution is altered
depending on the operational
mode of the unit
Round flange : CZ-160DAF2 ␸200 outlet frange x 4 ports
Circle duct flange (option)
Number of exits with diameters
2 x Ø 200
3 x Ø 200
4 x Ø 200
Model Code
CZ-56DAF2 (2 SA outlet)
CZ-90DAF2 (3 SA outlet)
CZ-160DAF2 (4 SA outlet)
27
Range of Commercial units
Wall Mounted for professional applications
Wall Mounted PKEA*
2,8 kW
3,2 kW
4,5 kW
5,0 kW
CS-E9PKEA
CS-E12PKEA
CS-E15PKEA
CS-E18PKEA
3,6 kW
4,5 kW
5,0 kW
6,0 kW
S-36PK1E5A
S-45PK1E5A
S-50PK1E5A
S-60PK1E5A
S-36PY2E5A
S-45PY2E5A
S-50PY2E5A
S-36PU1E5A
S-45PU1E5A
S-50PU1E5A
S-60PU1E5A
S-36PN1E5A
S-45PN1E5A
S-50PN1E5A
S-60PN1E5A
S-36PF1E5A
S-45PF1E5A
S-50PF1E5A
S-60PF1E5A
S-36PT2E5A
S-45PT2E5A
S-50PT2E5A
S-60PT2E5A
5,0 kW
6,0 kW
* PKEA indoor units are only compatible with PKEA Outdoor Units.
Indoor Units PACi Standard And Elite
Wall PACi Inverter+
4 Way 60x60 Cassette
PACi Inverter+
4 Way 90x90 Cassette
PACi Inverter+
Low Static Pressure Hide Away
PACi Inverter+
High Static Pressure Hide Away
PACi Inverter+
Ceiling
PACi Inverter+
High Static Pressure Hide Away 20,0 - 25,0 kW
PACi Inverter+
NEW
Air Curtain with DX Coil Jet-Flow
Air Curtain with DX Coil Standard
* The indoor units from 3,6 to 5,0 kW are only available only for Twin, Triple and Doble-Twin combinations.
Outdoor Units PACi Standard and Elite
PACi Standard
U-60PEY1E5 I
PACi Elite
U-50PE1E5 I
I
Single Phase III Three Phase
28
U-60PE1E5A I
NEW __ COMMERCIAL
Air Handling Unit
2 types of AHU Kit: Advanced and Standard.
Up to 28 kW
28,0 kW
PAW-280PAH2
PAW-280PAH2L
(Common use for all outdoor units. Only 1 by 1 connection is allowed.)
7,1 kW
10,0 kW
12,5 kW
14,0 kW
S-71PK1E5A
S-100PK1E5A (9,5 kW)
S-71PU1E5A
S-100PU1E5A
S-125PU1E5A
S-140PU1E5A
S-71PN1E5A
S-100PN1E5A
S-125PN1E5A
S-140PN1E5A
S-71PF1E5A
S-100PF1E5A
S-125PF1E5A
S-140PF1E5A
S-71PT2E5A
S-100PT2E5A
S-125PT2E5A
S-140PT2E5A
PAW-10PAIRC-MJ (9,2 kW)
PAW-15PAIRC-MJ (17,5 kW)
PAW-10PAIRC-MS (9,2 kW)
PAW-20PAIRC-MS (17,5 kW)
7,1 kW
10,0 kW
12,5 kW
14,0 kW
U-71PEY1E5 I
U-100PEY1E5 I // U-100PEY1E8 III
U-125PEY1E5 I // U-125PEY1E8 III
U-140PEY1E8 III
U-71PE1E5A I // U-71PE1E8A III
U-100PE1E5A I // U-100PE1E8A III
U-125PE1E5A I // U-125PE1E8A III
U-140PE1E5A I // U-140PE1E8A III
20,0 kW
25,0 kW
S-200PE2E5
S-250PE2E5
PAW-20PAIRC-MJ (23,1kW)
20,0 kW
25,0 kW
U-200PE1E8 III
U-250PE1E8 III
29
Complete line-up with high efficiency even at -15°C
This Wall Mounted air conditioner is especially designed for professional applications such as computer rooms
where cooling inside the room is necessary even when the outside temperature is low. Furthermore this air
conditioner has an automatic changeover system, in order to maintain the inside temperature even when sharp
outside temperature changes occur.
WALL MOUNTED PKEA
ROOM
· SERVER ITH THE
W
SOLUTIONEFFICIENCY
HIGHEST MARKET
OF THE RATION
E
· 24/7 OP
Internet
7,10 A++
4,40 A+
SCOP
AL
SEER
N
Control
Ready
TIO
saving
OP
Energy
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
Down to
Down to
-15°C in
-15°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
SEASONAL COEFFICIENT
OF PERFORMANCE
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
SEER and SCOP: For KIT-E9-PKEA.
KIT
Indoor
Outdoor
Cooling capacity
1)
Nominal (Min-Max)
Nominal (Min-Max)
Nominal (Min - Max)
Nominal
Nominal
Nominal
Nominal
Nominal
EER
Cooling capacity at -10°C
EER at -10°C
Cooling capacity at -20°C
EER at -20°C
SEER 2)
Pdesign
Power input cooling
Nominal (Min-Max)
Annual electricity consumption (cooling) 3)
Heating capacity
Nominal (Min-Max)
Nominal (Min-Max)
Nominal
Heating capacity at -7°C 4)
Nominal (Min - Max)
COP 1)
Nominal
SCOP 5)
Pdesign at -10 °C
Power input heating
Nominal (Min-Max)
Annual electricity consumption (heating) 3)
Indoor Unit
Power source
Recommended fuse
Connection indoor / outdoor
Current (Nominal)
Cooling / Heating
Max. Current
Air Volume
Cooling / Heating
Moisture removal volume
Sound pressure level 6)
Cooling (Hi / Lo / S-Lo)
Heating (Hi / Lo / S-Lo)
Sound power level
Cooling / Heating (Hi)
Dimensions / Net weight
HxWxD
Air purifier filter
Outdoor Unit
Air Volume
Cooling / Heating
Cooling / Heating (Hi)
Sound pressure level 6)
Sound power level
Cooling / Heating (Hi)
HxWxD
Dimensions 7) / Net weight
Piping connections
Liquid pipe / Gas pipe
Refrigerant loading
R410A
Elevation difference (in/out) 8) Max
Piping length
Min / Max
Precharge length
Max
Additional charge
Operating range
Cooling Min / Max
Heating Min / Max
kW
kCal/h
Energy Saving
kW
W/W
kW
W/W
W/W
kW
kW
kWh/a
kW
kCal/h
kW
Energy Saving
W/W
kW
kW
kWh/a
Single Phase
2,8 kW
KIT-E9-PKEA
CS-E9PKEA
CU-E9PKEA
2,50 (0,85-3,00)
2.150 (730-2.580)
4,85 (4,23-5,00) A
2,63
7,19
2,61
6,71
7,1 i
2,5
0,515 (0,170-0,710)
123
3,40 (0,85-5,40)
2.920 (730-4.640)
3,33
4,86 (4,12-5,15) A
4,4 h
2,8
0,700 (0,165-1,310)
891
3,2 kW
KIT-E12-PKEA
CS-E12PKEA
CU-E12PKEA
3,50 (0,85-4,00)
3.010 (730-3.440)
4,02 (3,57-5,00) A
3,69
5,96
3,66
5,56
6,7 i
3,5
0,870 (0,170-1,120)
183
4,00 (0,85-6,60)
3.440 (730-5.680)
4,07
4,35 (3,63-5,15) A
4,1 h
3,6
0,920 (0,165-1,820)
1.229
4,5 kW
KIT-E15-PKEA
CS-E15PKEA
CU-E15PKEA
4,20 (0,98-5,00)
3.610 (840-4.300)
3,50 (3,50-3,16) A
5,04
6,01
4,06
4,39
6,3 i
4,2
1,200 (0,280-1,580)
233
5,40 (0,98-7,10)
4.640 (840-6.110)
4,10
3,75 (2,88-3,24) A
3,9 a
3,6
1,440 (0,340-2,190)
1.292
5,0 kW
KIT-E18-PKEA
CS-E18PKEA
CU-E18PKEA
5,00 (0,98-6,00)
4.300 (840-5.160)
3,47 (3,50-3,02) A
6,00
6,00
5,82
5,39
6,9 i
5,0
1,440 (0,280-1,990)
254
5,80 (0,98-8,00)
4.990 (840-6.880)
4,98
3,82 (2,88-3,11) A
4,2 h
4,4
1,520 (0,340-2,570)
1.467
V
A
mm
A
A
m³/h
l/h
dB(A)
dB(A)
dB
mm / kg
230
16
4 x 1,5
2,5 / 3,3
7,8
798 / 876
1,5
39 / 26 / 23
40 / 27 / 24
55 / 56
295 x 870 x 255 / 10
230
16
4 x 1,5
4,0 / 4,2
8,4
816 / 882
2,0
42 / 29 / 26
42 / 33 / 29
58 / 58
295 x 870 x 255 / 10
230
16
4 x 1,5
5,4 / 6,5
9,6
846 / 900
2,4
43 / 32 / 29
43 / 35 / 29
59 / 59
295 x 870 x 255 / 10
230
16
4 x 2,5
6,4 / 6,8
11,3
1.074 / 1.158
2,8
44 / 37 / 34
44 / 37 / 34
60 / 60
295 x 1.070 x 255 / 13
m³/h
dB(A)
dB
mm / kg
inch (mm)
kg
m
m
m
g/m
°C
°C
1.878 / 1.782
46 / 47
61 / 62
622 x 824 x 299 / 36
1/4" (6,35) / 3/8" (9,52)
1.100
5
3-15
7,5
20
-15 / +43
-15 / +24
1.974 / 1.926
48 / 50
63 / 65
622 x 824 x 299 / 36
1/4" (6,35) / 3/8" (9,52)
1.100
5
3-15
7,5
20
-15 / +43
-15 / +24
2.052 / 1.980
46 / 46
61 / 61
695 x 875 x 320 / 45
1/4" (6,35) / 1/2" (12,70)
1,060
15
3-15
7,5
20
-15 / +43
-15 / +24
2.352 / 2.274
47 / 47
61 / 61
695 x 875 x 320 / 46
1/4" (6,35) / 1/2" (12,70)
1,240
15
3-20
7,5
20
-15 / +43
-15 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb).
Rating Conditions for cooling capacity at low temperature: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 0°C DB / -10°C WB.
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50,
EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal
temperatures are taken at 27°C DB and 19°C WB. 3) The annual consumption (ErP) is calculated by formula determined by ErP regulation. 4) Heating capacity is calculated including defrost factor correction. 5) SCOP is calculated in base Eurovent IPLV for SBEM with U1
indoor unit including defrost correction factor. 6) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97
specification. 7) Add 70 mm for piping port. 8) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // Specifications subject to change without notice.
For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
30
NEW __ COMMERCIAL
Technical focus
Features
· This units can be installed on R22 pipings
Outdoor
· Cooling even when ambient temperature is as low as -15°C
· Electronic expansion valve (accurate sub-cooling and adjustable
refrigerant flow)
· Outdoor DC fan motor to provide flexible air-flow to ensure optimum
condensation pressure (works on outdoor pipe temperature sensor)
· Designed for 24h/7d a week operation
· Highly efficient even at -15°C
· High durability rolling bearings
· Additional piping sensors to prevent freezing
Interface option to manage server room operation
The PAW-SERVER-PKEA server room interface manages redundancy and
backup of two PKEA units with two different selectable modes:
· Plug and play by embedded redundancy and backup algorithm (no
external signal needed. Further details please refer to operation manual)
· External (third party PLC) redundancy and backup management by dry
contact
All settings are possible without the need for a computer connection.
A special Energy Saving Mode is selectable by deep switch (available only
in plug and play mode).
The level of remote control input prohibition can be set when external
management is by dry contact.
Dry contacts
Optional accessory: PAW-SERVER-PKEA
ROTARY
INVERTER COMPRESSOR
CU-E9PKEA
CU-E12PKEA
CU-E15PKEA
CU-E18PKEA
Included on the kit
Timer remote controller
31
New Wall Mounted PACi. The extension of the range
to include a 10 kW unit allows for many more
applications such as studios, gyms, high ceiling
areas and even computer server rooms.
WALL MOUNTED
PACi STANDARD AND ELITE
INVERTER+
Technical Focus
· 10,0 kW capacity unit
· Flat face design for modern appearance
· Compact design offers over 15% reduction in overall size
· Washable front panel
· DC FAN for better efficiency and control
· Three directional piping outlet
· Easy connection and control of external fan or ERV using
the connector PAW-FDC on the indoor unit PCB. The
external device can be control by the remote control of the
Panasonic indoor unit
STANDARD
KIT
Indoor
Outdoor
Timer remote controller
Cooling capacity
Nominal (Min - Max)
Nominal (Min - Max)
EER 1)
2)
SEER
Pdesign
Power input cooling
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Heating capacity
Nominal (Min - Max)
Nominal
Heating capacity at -7°C 4)
Heating capacity at -15°C 4) Nominal
1)
Nominal (Min - Max)
COP
SCOP 5)
Pdesign at -10°C
Power input heating
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Indoor unit
Air volume
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Moisture removal volume
Cooling (Hi / Med / Lo)
Sound pressure level 6)
Heating (Hi / Med / Lo)
Sound power level
Cooling (Hi)
Heating (Hi)
Dimensions / Net weight
HxWxD
Outdoor unit
Power source
Recommended fuse
Connection
Current
Cooling
Heating
Air volume
Cooling / Heating
Sound pressure level
Cooling / Heating (Hi)
Sound power level
Cooling / Heating (Hi)
Dimensions / Net weight
HxWxD
Piping connections
Liquid pipe
Gas pipe
Refrigerant loading
R410A
Elevation difference (in/out) 7) Max
Piping length
Min / Max
Precharge length
Max
Additional charge
Operating range
Cooling Min / Max
Heating Min / Max
kW
W/W
W/W
kW
kW
kWh/a
kW
kW
kW
W/W
W/W
kW
kW
kWh/a
Single Phase
6,0 kW
KIT-60PKY1E5A
S-60PK1E5A
U-60PEY1E5
CZ-RTC4
6,0 (2,0 - 7,0)
3,23 (6,15 - 2,55) A
5,4 a
6,0
1,860 (0,325 - 2,750)
389
6,0 (1,8 - 7,0)
4,99
4,20
4,00 (6,55 - 3,18) A
3,9 a
6,0
1,500 (0,275 - 2,200)
2.154
7,1 kW
KIT-71PKY1E5A
S-71PK1E5A
U-71PEY1E5
CZ-RTC4
7,1 (2,0 - 7,7)
2,90 (6,15 - 2,57) C
5,1 a
7,1
2,450 (0,325 - 3,000)
487
7,1 (1,8 - 8,1)
5,08
4,37
3,74 (6,55 - 3,18) A
3,9 a
6,0
1,900 (0,275 - 2,550)
2.154
10,0 kW
KIT-100PKY1E5A
S-100PK1E5A
U-100PEY1E5
CZ-RTC4
9,0 (2,7 - 9,7)
2,67 (5,09 - 2,55) D
5,8 h
9,0
3,370 (0,530 - 3,800)
543
9,0 (2,1 - 10,5)
9,97
8,43
3,70 (5,12 - 3,50) A
3,8 a
9,0
2,430 (0,410 - 3,000)
3.316
Three Phase
10,0 kW
KIT-100PKY1E8A
S-100PK1E5A
U-100PEY1E8
CZ-RTC4
9,0 (2,7 - 9,7)
2,67 (5,09 - 2,55) D
5,7 h
9,0
3,370 (0,530 - 3,800)
553
9,0 (2,1 - 10,5)
9,97
8,43
3,70 (5,12 - 3,50) A
3,8 a
9,0
2,430 (0,410 - 3,000)
3.316
m³/h
m³/h
l/h
dB(A)
dB(A)
dB
dB
mm / kg
1.080 / 870 / 690
1.080 / 870 / 690
3,4
47 / 44 / 40
47 / 44 / 40
64
64
300 x 1.065 x 230 / 14,5
1.080 / 870 / 690
1.080 / 870 / 690
4,2
47 / 44 / 40
47 / 44 / 40
64
64
300 x 1.065 x 230 / 14,5
1.140 / 990 / 780
1.140 / 990 / 780
5,4
49 / 45 / 41
49 / 45 / 41
65
65
300 x 1.065 x 230 / 14.5
1.140 / 990 / 780
1.140 / 990 / 780
5,4
49 / 45 / 41
49 / 45 / 41
65
65
300 x 1.065 x 230 / 14.5
V
A
mm²
A
A
m³/h
dB(A)
dB
mm / kg
Inch (mm)
Inch (mm)
kg
m
m
m
g/m
°C
°C
220 / 230 / 240
20
2,5
8,80 / 8,50 / 8,25
7,05 / 6,80 / 6,60
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285 / 42
3/8 (9,52)
5/8 (15,88)
1,7
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
20
2,5
11,7 / 11,3 / 10,9
9,00 / 8,70 / 8,40
2.340 / 2.340
50 / 52
70 / 70
569 x 790 x 285 / 42
3/8 (9,52)
5/8 (15,88)
1,7
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
25
4,0
16,0 / 15,3 / 14,6
11,2 / 10,8 / 10,4
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340 / 73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
5,40 / 5,15 / 4,95
3,85 / 3,65 / 3,55
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340 / 73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50,
EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal
temperatures are taken at 27°C DB and 19°C WB. 3) The annual consumption (ErP) is calculated by formula determined by ErP regulation. 4) Heating capacity is calculated including defrost factor correction. 5) SCOP is calculated in base Eurovent IPLV for SBEM with U1
indoor unit including defrost correction factor. 6) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1,5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97
specification. 7) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
STANDARD
Internet
Energy
5,40 A
SEER
SCOP
N
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-60PKY1E5A.
32
3,90 A
AL
saving
OP
TIO
Control
Ready
SEASONAL COEFFICIENT
OF PERFORMANCE
Down to
Down to
-10°C in
-15°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-60PEY1E5
U-71PEY1E5
U-100PEY1E5 U-100PEY1E8
NEW __ COMMERCIAL
HIGH
HEATING
CAPACIT Y
AT -7°C
Optional Controller
Wired remote controller
CZ-RTC5
Optional Controller
Timer remote controller
CZ-RTC4
Optional Controller
Wireless remote controller
CZ-RWSK2
Optional Controller
Simplified remote controller
CZ-RE2C2
Compatible with all Panasonic connectivity solutions. For detailed information go to the Control Systems section.
ELITE
KIT
Indoor
Outdoor
Timer remote controller
Cooling capacity
Nominal (Min - Max)
Nominal (Min - Max)
EER 1)
2)
SEER
Pdesign
Power input cooling
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Heating capacity
Nominal (Min - Max)
Nominal
Heating capacity at -7°C 4)
Heating capacity at -15°C 4) Nominal
1)
Nominal (Min - Max)
COP
SCOP 5)
Pdesign at -10°C
Power input heating
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Indoor unit
Air volume
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Moisture removal volume
Cooling (Hi / Med / Lo)
Sound pressure level 6)
Heating (Hi / Med / Lo)
Sound power level
Cooling (Hi)
Heating (Hi)
Dimensions / Net weight
HxWxD
Outdoor unit
Power source
Recommended fuse
Connection
Current
Cooling
Heating
Air volume
Cooling / Heating
Sound pressure level
Cooling / Heating (Hi)
Sound power level
Cooling / Heating (Hi)
Dimensions / Net weight
HxWxD
Piping connections
Liquid pipe
Gas pipe
Refrigerant loading
R410A
Elevation difference (in/out) 7) Max
Piping length
Min / Max
Precharge length
Max
Additional charge
Operating range
Cooling Min / Max
Heating Min / Max
kW
W/W
W/W
kW
kW
kWh/a
kW
kW
kW
W/W
W/W
kW
kW
kWh/a
Single Phase
5,0 kW
KIT-50PK1E5A
S-50PK1E5A
U-50PE1E5
CZ-RTC4
5,0 (1,5 - 5,6)
3,21 (5,77 - 2,49) A
6,0 h
5,0
1,560 (0,260 - 2,250)
292
5,6 (1,5 - 6,5)
4,20
3,58
3,73 (6,82 - 2,65) A
3,9 a
4,0
1,500 (0,220 - 2,450)
1.436
6,0 kW
KIT-60PK1E5A
S-60PK1E5A
U-60PE1E5A
CZ-RTC4
6,0 (2,5 - 7,1)
3,85 (5,56 - 3,55) A
6,6 i
6,0
1,560 (0,450 - 2,000)
318
7,0 (2,0 - 8,0)
6,69
6,56
3,85 (5,00 - 3,23) A
3,9 a
6,0
1,820 (0,400 - 2,480)
2.154
7,1 kW
KIT-71PK1E5A
S-71PK1E5A
U-71PE1E5A
CZ-RTC4
7,1 (2,5 - 8,0)
3,40 (5,56 - 3,02) A
6,6 i
7,1
2,090 (0,450 - 2,650)
376
8,0 (2,0 - 9,0)
7,52
7,65
3,76 (5,00 - 3,10) A
3,9 a
7,1
2,130 (0,400 - 2,900)
2.548
10,0 kW
KIT-100PK1E5A
S-100PK1E5A
U-100PE1E5A
CZ-RTC4
9,5 (3,3 - 10,5)
3,25(3,93 - 3,09)A
6,2 i
9,5
2,920 (0,840 - 3,400)
536
9,5 (4,1 - 11,5)
12,04
11,20
3,85 (4,56 - 3,43) A
3,8 a
9,5
2,470 (0,900 - 3,350)
3.500
Three Phase
7,1 kW
KIT-71PK1E8A
S-71PK1E5A
U-71PE1E8A
CZ-RTC4
7,1 (3,2 - 8,0)
3,40 (5,71 - 3,02) A
6,1 i
7,1
2,090 (0,560 - 2,650)
407
8,0 (2,8 - 9,0)
7,52
7,65
3,76 (5,60 - 3,10) A
3,8 a
7,1
2.130 (0.500-2.900)
2.616
10,0 kW
KIT-100PK1E8A
S-100PK1E5A
U-100PE1E8A
CZ-RTC4
9,5 (3,3 - 10,5)
3,25(3,93 - 3,09)A
6,0 h
9,5
2,920 (0,840 - 3,400)
554
9,5 (4,1 - 11,5)
12,04
11,20
3,85 (4,56 - 3,43) A
3,8 a
9,5
2,470 (0,900 - 3,350)
3.500
m³/h
m³/h
l/h
dB(A)
dB(A)
dB
dB
mm / kg
840 / 720 / 630
840 / 720 / 630
2,8
40 / 36 / 32
40 / 36 / 32
57
57
300 x 1.065 x 230 / 13,0
1.080 / 870 / 690
1.080 / 870 / 690
3,4
47 / 44 / 40
47 / 44 / 40
64
64
300 x 1.065 x 230 / 14,5
1.080 / 870 / 690
1.080 / 870 / 690
4,2
47 / 44 / 40
47 / 44 / 40
64
64
300 x 1.065 x 230 / 14,5
1.140 / 990 / 780
1.140 / 990 / 780
5.7
49/45/41
49/45/41
65
65
300 x 1065 x 230 / 14.5
1.080 / 870 / 690
1.080 / 870 / 690
4,2
47 / 44 / 40
47 / 44 / 40
64
64
300 x 1.065 x 230 / 14,5
1.140 / 990 / 780
1.140 / 990 / 780
5.7
49/45/41
49/45/41
65
65
300 x 1065 x 230 / 14.5
V
A
mm²
A
A
m³/h
dB(A)
dB
mm / kg
Inch (mm)
Inch (mm)
kg
m
m
m
g/m
°C
°C
220 / 230 / 240
16
2,5
7,25 / 7,00 / 6,80
6,95 / 6,75 / 6,50
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285 / 42
1/4 (6,35)
1/2 (12,7)
1,65
30
5 / 40
30
20
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
7,45 / 7,15 / 6,95
8,45 / 8,15 / 7,90
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340 / 68
3/8 (9,52)
5/8 (15,88)
2
30
5 / 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
9,75 / 9,40 / 9,10
9,85 / 9,50 / 9,20
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340 / 69
3/8 (9,52)
5/8 (15,88)
2,35
30
5 / 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
25
4
13,4 / 12,9 / 12,4
11,3 / 10,9 / 10,6
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340 / 98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
3,25 / 3,15 / 3,05
3,30 / 3,20 / 3,10
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340 / 71
3/8 (9,52)
5/8 (15,88)
2,35
30
5 / 50
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
4,60 / 4,40 / 4,30
3,85 / 3,70 / 3,60
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340 / 98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50, EER75
and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal temperatures
are taken at 27°C DB and 19°C WB. 3) The annual consumption (ErP) is calculated by formula determined by ErP regulation. 4) Heating capacity is calculated including defrost factor correction. 5) SCOP is calculated in base Eurovent IPLV for SBEM with U1 indoor unit
including defrost correction factor. 6) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1,5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 7) When
installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
ELITE
Internet
Energy
6,60 A++
3,90 A
SEER*
SCOP
SEASONAL ENERGY
EFFICIENCY RATIO
SEASONAL COEFFICIENT
OF PERFORMANCE
N
AL
saving
OP
TIO
Control
Ready
INTERNET CONTROL
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-60PK1E5A and KIT-71PK1E5A.
Down to
Down to
-15°C in
-20°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-50PE1E5
U-60PE1E5A U-71PE1E8A
U-71PE1E5A U-100PE1E8A
U-100PE1E5A
33
4 WAY 60x60 CASSETTE
PACi STANDARD AND ELITE
INVERTER+
Small and powerful, ideal for offices and restaurants.
Only for Twin, Triple and Double-twin combinations.
Technical Focus
· Fresh air knock out
· Multidirectional air flow
· Integrated drain pump gives 850 mm lift
· 3 speed centrifugal fan
· DC FAN for better efficiency and control
· Easy connection and control of external fan or ERV using
the connector PAW-FDC on the indoor unit PCB. The
external device can be control by the remote control of the
Panasonic indoor unit
STANDARD
Indoor
Panel
Cooling capacity
Heating capacity
Air volume
Moisture removal volume
Sound pressure level 6)
Sound power level
Dimensions (H x W x D)
Net weight
Nominal
Nominal
Cool/Heat
kW
kW
m³/h
l/h
Cooling (Hi / Med / Lo)
dB(A)
Heating (Hi / Med / Lo)
dB(A)
Cooling (Hi)
dB
Heating (Hi)
dB
Indoor
mm
Panel CZ-KPY3A / CZ-KPY3B mm
Indoor (Panel)
kg
3,6 kW
S-36PY2E5A1)*
CZ-KPY3A / CZ-KPY3B
3,6
4,2
582 / 594
2,1
36 / 32 / 26
36 / 32 / 26
51 / 47 / 41
51 / 47 / 41
288 x 583 x 583
31 x 700 x 700 / 31 x 625 x 625
18 (2,4)
4,5 kW
S-45PY2E5A1)*
CZ-KPY3A / CZ-KPY3B
4,5
5,2
600 / 618
2,5
38 / 34 / 28
38 / 34 / 28
53 / 49 / 43
53 / 49 / 43
288 x 583 x 583
31 x 700 x 700 / 31 x 625 x 625
18 (2,4)
5,0 kW
S-50PY2E5A*
CZ-KPY3A / CZ-KPY3B
5,0
5,6
666 / 666
2,8
40 / 37 / 33
40 / 37 / 33
55 / 52 / 48
55 / 52 / 48
288 x 583 x 583
31 x 700 x 700 / 31 x 625 x 625
18 (2,4)
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.
1) Only for multi combinations.
Recommended fuse for the indoor 3A.
STANDARD
34
NEW __ COMMERCIAL
HIGH
HEATING
CAPACIT Y
AT -7°C
Optional Controller
Wired remote controller
CZ-RTC5
Panel
CZ-KPY3A (size 700 x 700mm)
CZ-KPY3B (size 625 x 625mm)
Optional Controller
Timer remote controller
CZ-RTC4
Optional Controller
Wireless remote controller
CZ-RWSK2
Optional Controller
Simplified remote controller
CZ-RE2C2
Compatible with all Panasonic connectivity solutions. For detailed information go to the Control Systems section.
ELITE
KIT
Indoor
Outdoor
Panel
Timer remote controller
Cooling capacity
EER 1)
SEER 2)
Pdesign
Power input cooling
Annual energy consumption (ErP) 3)
Heating capacity
Heating capacity at -7°C 4)
Heating capacity at -15°C 4)
COP 1)
SCOP 5)
Pdesign at -10°C
Power input heating
Annual energy consumption (ErP) 3)
Indoor unit
Air volume
Moisture removal volume
Sound pressure level 6)
Nominal (Min - Max)
Nominal (Min - Max)
Nominal (Min - Max)
Nominal (Min - Max)
Nominal
Nominal
Nominal (Min - Max)
Nominal (Min - Max)
Cooling / Heating
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
Cooling (Hi)
Heating (Hi)
Indoor
Panel CZ-KPY3A / CZ-KPY3B
Indoor (Panel)
Sound power level
Dimensions (H x W x D)
Net weight
Outdoor unit
Power source
Recommended fuse
Connection
Current
Air volume
Sound pressure level
Sound power level
Dimensions
Net weight
Piping connections
Refrigerant Loading
Elevation difference (in/out) 7)
Piping length
Precharge length
Additional gas
Operating range
Cooling / Heating
Cooling / Heating
Cooling / Heating (Hi)
Cooling / Heating (Hi)
HxWxD
Liquid pipe / Gas pipe
R410A
Max
Min / Max
Max
Cooling Min / Max
Heating Min / Max
kW
W/W
W/W
kW
kW
kWh/a
kW
kW
kW
W/W
W/W
kW
kW
kWh/a
5,0 kW
KIT-50PY2E5A
S-50PY2E5A
U-50PE1E5
CZ-KPY3A / CZ-KPY3B
CZ-RTC4
5,0 (1,5 - 5,6)
3,04 (5,77 - 2,29)
5,90 h
5,0
1,64 (0,260 - 2,45)
297
5,6 (1,5 - 6,3)
4,20
3,58
3,12 (6,82 - 2,45)
3,80 a
4,0
1,79 (0,22 - 2,57)
1.474
m³/h
l/h
dB(A)
dB(A)
dB
dB
mm
mm
kg
666 / 666
2,8
40 / 37 / 33
40 / 37 / 33
55 / 52 / 48
55 / 52 / 48
288 x 583 x 583
31 x 700 x 700 / 31 x 625 x 625
18 (2,4)
V
A
mm²
A
m³/h
dB(A)
dB
mm
kg
Inch (mm)
kg
m
m
m
g/m
°C
°C
220 - 240
16
2,5
7,5 / 8,2
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
1/4 (6,35) / 1/2 (12,7)
1,65
30
5 ~ 40
30
20
-15 / +46
-20 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50,
EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal
temperatures are taken at 27°C DB and 19°C WB. 3) The annual consumption (ErP) is calculated by formula determined by ErP regulation. 4) Heating capacity is calculated including defrost factor correction. 5) SCOP is calculated in base Eurovent IPLV for SBEM with U1
indoor unit including defrost correction factor. 6) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1,5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97
specification. 7) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
ELITE
Internet
Energy
5,90 A+
SEER
3,80 A
SCOP
N
AL
saving
OP
TIO
Control
Ready
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
SEASONAL COEFFICIENT
OF PERFORMANCE
Down to
Down to
-15°C in
-20°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-50PE1E5
INTERNET CONTROL READY: Optional.
35
The 4 Way 90x90 Cassette incorporates many new
benefits thanks to advances in design and
technology.
4 WAY 90x90 CASSETTE
PACi STANDARD AND ELITE
INVERTER+
Technical Focus
·
·
·
·
·
·
·
·
·
Circle Flow Flap for more even temp. distribution
Higher efficiency split fin
New DC fan motor
Highly efficient and silent turbo fan
Individual flap control for flexible air flow direction
Easy to clean suction grill & flap
Special adjustment for high ceiling application
DC FAN for better efficiency and control
Easy connection and control of external fan or ERV using
the connector PAW-FDC on the indoor unit PCB. The
external device can be control by the remote control of the
Panasonic indoor unit
STANDARD
KIT
Indoor
Outdoor
Panel
Timer remote controller
Cooling capacity
Nominal (Min - Max)
EER 1)
Nominal (Min - Max)
Nominal (Min - Max)
SEER 2)
Pdesign
Power input cooling
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Heating capacity
Nominal (Min - Max)
Heating capacity at -7°C 4)
Nominal
4)
Nominal
Heating capacity at -15°C
1)
COP
Nominal (Min - Max)
5)
Nominal (Min - Max)
SCOP
Pdesign at -10°C
Power input heating
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Indoor unit
Air volume
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Moisture removal volume
Sound pressure level 6)
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Sound power level
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Dimensions (H x W x D)
Indoor
Panel
Net weight
Indoor (Panel)
Outdoor unit
Power source
Recommended fuse
Connection
Current
Cooling
Heating
Air volume
Cooling / Heating
Sound pressure level
Cooling / Heating (Hi)
Sound power level
Cooling / Heating (Hi)
Dimensions
HxWxD
Net weight
Piping connections
Liquid pipe / Gas pipe
Refrigerant loading
R410A
Elevation difference (in/out) 7) Max
Piping length
Min / Max
Precharge length
Max
Additional charge
Operating range
Cooling Min / Max
Heating Min / Max
kW
W/W
W/W
kW
kW
kWh/a
kW
kW
kW
W/W
W/W
kW
kW
kWh/a
Single Phase
6,0 kW
KIT-60PUY1E5A
S-60PU1E5A
U-60PEY1E5
CZ-KPU21
CZ-RTC4
6,0 (2,0 - 7,0)
3,55 (6,15 - 2,80) A
6,8 i
6,0
1,690 (0,325 - 2,500)
309
6,0 (1,8 - 7,0)
4,99
4,20
4,05 (6,55 - 3,25) A
4,0 h
6,0
1,480 (0,275 - 2,155)
2.100
7,1 kW
KIT-71PUY1E5A
S-71PU1E5A
U-71PEY1E5
CZ-KPU21
CZ-RTC4
7,1 (2,0 - 7,7)
3,24 (6,15 - 2,75) A
6,3 i
7,1
2,190 (0,325 - 2,800)
394
7,1 (1,8 - 8,1)
5,08
4,37
3,78 (6,55 - 3,23) A
4,0 h
6,0
1,880 (0,275 - 2,510)
2.100
10,0 kW
KIT-100PUY1E5A
S-100PU1E5A
U-100PEY1E5
CZ-KPU21
CZ-RTC4
10,0 (2,7 - 11,5)
3,11 (5,09 - 2,74) B
6,4 i
10
3,220 (0,530 - 4,200)
547
10,0 (2,1 - 13,8)
9,97
8,43
3,80 (5,12 - 3,45) A
4,0 h
10,0
2,630 (0,410 - 4,000)
3.500
12,5 kW
KIT-125PUY1E5A
S-125PU1E5A
U-125PEY1E5
CZ-KPU21
CZ-RTC4
12,5 (3,8 - 13,5)
3,11 (4,22 - 2,70) B
—
—
4,020 (0,900 - 5,000)
—
12,5 (3,4 - 15,0)
10,97
9,03
3,80 (4,66 - 3,41) A
—
—
3,290 (0,730 - 4,400)
—
Three Phase
10,0 kW
KIT-100PUY1E8A
S-100PU1E5A
U-100PEY1E8
CZ-KPU21
CZ-RTC4
10,0 (2,7 - 11,5)
3,11 (5,09 - 2,74) B
6,2 i
10,0
3,220 (0,530 - 4,200)
564
10,0 (2,1 - 13,8)
9,97
8,43
3,80 (5,12 - 3,45) A
4,0 h
10,0
2,630 (0,410 - 4,000)
3.500
12,5 kW
KIT-125PUY1E8A
S-125PU1E5A
U-125PEY1E8
CZ-KPU21
CZ-RTC4
12,5 (3,8 - 13,5)
3,11 (4,22 - 2,70) B
—
—
4,020 (0,900 - 5,000)
—
12,5 (3,4 - 15,0)
10,97
9,03
3,80 (4,66 - 3,41) A
—
—
3,290 (0,730 - 4,400)
—
14,0 kW
KIT-140PUY1E8A
S-140PU1E5A
U-140PEY1E8
CZ-KPU21
CZ-RTC4
14,0 (3,3 - 15,5)
3,21 (3,93 - 2,58) A
—
—
4,36 (0,84 - 6,00)
—
14,0 (4,1 - 16,0)
13,35
12,38
3,89 (4,56 - 3,08) A
—
—
3,60 (0,90 - 5,20)
—
m³/h
m³/h
l/h
dB(A)
dB(A)
dB
dB
mm
mm
kg
1.260 / 1.020 / 840
1.260 / 1.020 / 840
3,4
36 / 31 / 28
36 / 31 / 28
53 / 48 / 45
53 / 48 / 45
256 x 840 x 840
33,5 x 950 x 950
24 (4)
1.320 / 1.020 / 840
1.320 / 1.020 / 840
4,2
37 / 31 / 28
37 / 31 / 28
54 / 48 / 45
54 / 48 / 45
256 x 840 x 840
33,5 x 950 x 950
24 (4)
1.980 / 1.620 / 1.260
1.980 / 1.620 / 1.260
6,0
44 / 38 / 32
44 / 38 / 32
62 / 55 / 49
62 / 55 / 49
319 x 840 x 840
33,5 x 950 x 950
27 (4)
2.100 / 1.680 / 1.320
2.100 / 1.680 / 1.320
7,9
45 / 39 / 33
45 / 39 / 33
63 / 56 / 50
63 / 56 / 50
319 x 840 x 840
33,5 x 950 x 950
27 (4)
1.980 / 1.620 / 1.260
1.980 / 1.620 / 1.260
6,0
44 / 38 / 32
44 / 38 / 32
62 / 55 / 49
62 / 55 / 49
319 x 840 x 840
33,5 x 950 x 950
27 (4)
2.100 / 1.680 / 1.320
2.100 / 1.680 / 1.320
7,9
45 / 39 / 33
45 / 39 / 33
63 / 56 / 50
63 / 56 / 50
319 x 840 x 840
33,5 x 950 x 950
27 (4)
2.160 / 1.740 / 1.380
2.160 / 1.740 / 1.380
9,0
46 / 40 / 34
46 / 40 / 34
64 / 57 / 51
64 / 57 / 51
319 x 840 x 840
33,5 x 950 x 950
27 (4)
V
A
mm²
A
A
m³/h
dB(A)
dB
mm
kg
Inch (mm)
kg
m
m
m
g/m
°C
°C
220 / 230 / 240
20
2,5
8,30 / 7,90 / 7,60
7,20 / 6,90 / 6,60
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
3/8 (9,52) / 5/8 (15,88)
1,7
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
20
2,5
10,70 / 10,30 / 9,80
9,10 / 8,70 / 8,30
2340
50 / 52
70 / 70
569 x 790 x 285
42
3/8 (9,52) / 5/8 (15,88)
1,7
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
25
4
15,10 / 14,40 / 13,80
12,00 / 11,60 / 11,20
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340
73
3/8 (9,52) / 5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
220 / 230 / 240
30
6
19,2 / 18,4 / 17,6
15,4 / 14,8 / 14,2
4.800 / 4.380
56 / 56
73 / 73
996 x 940 x 340
85
3/8 (9,52) / 5/8 (15,88)
3,20
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
5,10 / 4,85 / 4,70
4,15 / 3,95 / 3,80
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340
73
3/8 (9,52) / 5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
6,35 / 6,05 / 5,80
5,15 / 4,90 / 4,70
4.800 / 4.380
56 / 56
73 / 73
996 x 940 x 340
85
3/8 (9,52) / 5/8 (15,88)
3,20
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
6,85 / 6,50 / 6,25
5,65 / 5,35 / 5,20
8.100 / 7.200
54 / 53
71 / 70
1.416 x 940 x 340
98
3/8 (9,52) / 5/8 (15,88)
3,4
30
5 / 50
30
50
-10 / +43
-15 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50,
EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal
temperatures are taken at 27°C DB and 19°C WB. 3) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 4) Heating capacity is calculated including defrost factor correction. 5) SCOP is calculated in base Eurovent IPLV for SBEM with U1
STANDARD
Internet
Energy
6,80 A++
SEER
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-60PUY1E5A.
36
4,00 A+
SCOP*
N
AL
saving
OP
TIO
Control
Ready
SEASONAL COEFFICIENT
OF PERFORMANCE
Down to
Down to
-10°C in
-15°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-60PEY1E5
U-71PEY1E5
U-100PEY1E5 U-100PEY1E8
U-125PEY1E5 U-125PEY1E8
U-140PEY1E8
NEW __ COMMERCIAL
HIGH
HEATING
CAPACIT Y
AT -7°C
Panel
CZ-KPU21
Optional Controller
Wired remote controller
CZ-RTC5
Optional Controller
Timer remote controller
CZ-RTC4
Optional Controller
Wireless remote controller
CZ-RWSU2
Optional Controller
Simplified remote controller
CZ-RE2C2
360º
air flow
Compatible with all Panasonic connectivity solutions. For detailed information go to the Control Systems section.
ELITE
Single Phase
5,0 kW
KIT-50PU1E5A
S-50PU1E5A
U-50PE1E5
CZ-KPU21
CZ-RTC4
5,0 (1,5 - 5,6)
3,70 (5,77 - 2,80) A
6,5 i
5,0
1,350 (0,260 - 2,000)
269
5,6 (1,5 - 6,5)
4,20
3,58
3,92 (6,82 - 2,83) A
3,8 a
4,0
1,430 (0,220 - 2,300)
1.474
6,0 kW
KIT-60PU1E5A
S-60PU1E5A
U-60PE1E5A
CZ-KPU21
CZ-RTC4
6,0 (2,5 - 7,1)
4,05 (5,56 - 3,55) A
7,4 i
6,0
1,480 (0,450 - 2,000)
284
7,0 (2,0 - 8,0)
6,69
6,56
3,87 (5,00 - 3,23) A
4,1 h
6,0
1,810 (0,400 - 2,480)
2.047
7,1 kW
KIT-71PU1E5A
S-71PU1E5A
U-71PE1E5A
CZ-KPU21
CZ-RTC4
7,1 (2,5 - 8,0)
3,94 (5,56 - 3,02) A
7,4 i
7,1
1,800 (0,450 - 2,650)
336
8,0 (2,0 - 9,0)
7,52
7,65
4,00 (5,0 0 - 3,10) A
4,1 h
7,1
2,000 (0,400 - 2,900)
2.424
10,0 kW
KIT-100PU1E5A
S-100PU1E5A
U-100PE1E5A
CZ-KPU21
CZ-RTC4
10,0 (3,3 - 12,5)
4,20 (3,93 - 3,38) A
6,6 i
10,0
2,380 (0,840 - 3,700)
530
11,2 (4,1 - 14,0)
12,04
11,20
4,31 (4,56 - 3,18) A
4,2 h
10,0
2,600 (0,900 - 4,400)
3.333
12,5 kW
KIT-125PU1E5A
S-125PU1E5A
U-125PE1E5A
CZ-KPU21
CZ-RTC4
12,5 (3,3 - 14,0)
3,60 (3,93 - 3,04) A
—
—
3,470 (0,840 - 4,600)
—
14,0 (4,1 - 16,0)
13,48
12,38
4,00 (4,56 - 3,08) A
—
—
3,500 (0,900 - 5,200)
—
14,0 kW
KIT-140PU1E5A
S-140PU1E5A
U-140PE1E5A
CZ-KPU21
CZ-RTC4
14,0 (3,3 - 15,5)
3,25 (3,93 - 2,58) A
—
—
4,310 (0,840 - 6,000)
—
16,0 (4,1 - 18,0)
14,24
12,69
3,70 (4,56 - 3,05) A
—
—
4,330 (0,900 - 5,900)
—
Three Phase
7,1 kW
KIT-71PU1E8A
S-71PU1E5A
U-71PE1E8A
CZ-KPU21
CZ-RTC4
7,1 (3,2 - 8,0)
3,94 (5,56 - 3,02) A
6,8 i
7,1
1,800 (0,560 - 2,650)
365
8,0 (2,8 - 9,0)
7,52
7,65
4,00 (5,60 - 3,10) A
4,0 h
7,1
2,000 (0,500 - 2,900)
2.485
10,0 kW
KIT-100PU1E8A
S-100PU1E5A
U-100PE1E8A
CZ-KPU21
CZ-RTC4
10,0 (3,3 - 12,5)
4,20 (3,93 - 3,38) A
6,5 i
10,0
2,380 (0,840 - 3,700)
538
11,2 (4,1 - 14,0)
12,04
11,20
4,31 (4,56 - 3,18) A
4,2 h
10,0
2,600 (0,900 - 4,400)
3.333
12,5 kW
KIT-125PU1E8A
S-125PU1E5A
U-125PE1E8A
CZ-KPU21
CZ-RTC4
12,5 (3,3 - 14,0)
3,60 (3,93 - 3,04) A
—
—
3,470 (0,840 - 4,600)
—
14,0 (4,1 - 16,0)
13,48
12,38
4,00 (4,56 - 3,08) A
—
—
3,500 (0,900 - 5,200)
—
14,0 kW
KIT-140PU1E8A
S-140PU1E5A
U-140PE1E8A
CZ-KPU21
CZ-RTC4
14,0 (3,3 - 15,5)
3,25 (3,93 - 2,58) A
—
—
4,310 (0,840 - 6,000)
—
16,0 (4,1 - 18,0)
14,24
12,69
3,70 (4,56 - 3,05) A
—
—
4,330 (0,900 - 5,900)
—
960 / 810 / 720
960 / 810 / 720
2,8
32 / 29 / 27
32 / 29 / 27
49 / 46 / 44
49 / 46 / 44
256 x 840 x 840
33,5 x 950 x 950
23 (4)
1.260 / 1.020 / 840
1.260 / 1.020 / 840
3,4
36 / 31 / 28
36 / 31 / 28
53 / 48 / 45
53 / 48 / 45
256 x 840 x 840
33,5 x 950 x 950
24 (4)
1.320 / 1.020 / 840
1.320 / 1.020 / 840
4,2
37 / 31 / 28
37 / 31 / 28
54 / 48 / 45
54 / 48 / 45
256 x 840 x 840
33,5 x 950 x 950
24 (4)
1.980 / 1.620 / 1.260
1.980 / 1.620 / 1.260
6,0
44 / 38 / 32
44 / 38 / 32
62 / 55 / 49
62 / 55 / 49
319 x 840 x 840
33,5 x 950 x 950
27 (4)
2.100 / 1.680 / 1.320
2.100 / 1.680 / 1.320
7,9
45 / 39 / 33
45 / 39 / 33
63 / 56 / 50
63 / 56 / 50
319 x 840 x 840
33,5 x 950 x 950
27 (4)
2.160 / 1.740 / 1.380
2.160 / 1.740 / 1.380
9,0
46 / 40 / 34
46 / 40 / 34
64 / 57 / 51
64 / 57 / 51
319 x 840 x 840
33,5 x 950 x 950
27 (4)
1.320 / 1.020 / 840
1.320 / 1.020 / 840
4,2
37 / 31 / 28
37 / 31 / 28
54 / 48 / 45
54 / 48 / 45
256 x 840 x 840
33,5 x 950 x 950
24 (4)
1.980 / 1.620 / 1.260
1.980 / 1.620 / 1.260
6,0
44 / 38 / 32
44 / 38 / 32
62 / 55 / 49
62 / 55 / 49
319 x 840 x 840
33,5 x 950 x 950
27 (4)
2.100 / 1.680 / 1.320
2.100 / 1.680 / 1.320
7,9
45 / 39 / 33
45 / 39 / 33
63 / 56 / 50
63 / 56 / 50
319 x 840 x 840
33,5 x 950 x 950
27 (4)
2.160 / 1.740 / 1.380
2.160 / 1.740 / 1.380
9,0
46 / 40 / 34
46 / 40 / 34
64 / 57 / 51
64 / 57 / 51
319 x 840 x 840
33,5 x 950 x 950
27 (4)
220 / 230 / 240
16
2,5
6,50 / 6,20 / 5,95
6,90 / 6,60 / 6,30
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
1/4 (6,35) / 1/2 (12,7)
1,65
30
5 / 40
30
20
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
7,15 / 6,90 / 6,70
8,50 / 8,20 / 7,95
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
68
3/8 (9,52) / 5/8 (15,88)
2
30
5 / 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
8,40 / 8,10 / 7,90
9,30 / 9,00 / 8,70
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
69
3/8 (9,52) / 5/8 (15,88)
2,35
30
5 / 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
25
4
10,7 / 10,3 / 9,90
11,8 / 11,4 / 11,0
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340
98
3/8 (9,52) / 5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
220 / 230 / 240
30
6
15,8 / 15,3 / 14,8
15,9 / 15,4 / 14,9
7.800 / 6.600
53 / 53
70 / 70
1.416 x 940 x 340
98
3/8 (9,52) / 5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
220 / 230 / 240
16
2,5
19,6 / 19,0 / 18,4
19,8 / 19,2 / 18,6
8.100 / 7.200
54 / 55
71 / 71
1.416 x 940 x 340
98
3/8 (9,52) / 5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
2,80 / 2,70 / 2,60
3,10 / 3,00 / 2,90
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
71
3/8 (9,52) / 5/8 (15,88)
2,35
30
5 / 50
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
3,70 / 3,50 / 3,40
4,05 / 3,85 / 3,75
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340
98
3/8 (9,52) / 5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
5,45 / 5,15 / 5,00
5,50 / 5,20 / 5,05
7.800 / 6.600
53 / 53
70 / 70
1.416 x 940 x 340
98
3/8 (9,52) / 5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
6,75 / 6,45 / 6,20
6,85 / 6,50 / 6,25
8.100 / 7.200
54 / 55
71 / 71
1.416 x 940 x 340
98
3/8 (9,52) / 5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
indoor unit including defrost correction factor. 6) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1,5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97
specification. 7) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A.
For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
ELITE
Internet
Energy
7,40 A++
SEER
4,10 A+
SCOP
N
AL
saving
OP
TIO
Control
Ready
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
SEASONAL COEFFICIENT
OF PERFORMANCE
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-60PU1E5A and KIT-71PU1E5A.
Down to
Down to
-15°C in
-20°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-50PE1E5
U-60PE1E5A
U-71PE1E5A
U-71PE1E8A
U-100PE1E5A U-100PE1E8A
U-125PE1E5A U-125PE1E8A
U-140PE1E5A U-140PE1E8A
37
The depth of only 250mm provides greater
installation flexibility and the unit can be used in
more applications. Ideal for sites with narrow ceiling
voids.
LOW STATIC PRESSURE
HIDE AWAY
PACi STANDARD AND ELITE
INVERTER+
Technical Focus
· Compact indoor units without loosing static pressure (Only
250 mm high)
· 50 Pa static pressure
· Easy maintenance and service via external electrical box
· 3 speed centrifugal fan through wired or wireless remote
control
· DC FAN for better efficiency and control
· Easy connection and control of external fan or ERV using
the connector PAW-FDC on the indoor unit PCB. The
external device can be control by the remote control of the
Panasonic indoor unit
STANDARD
KIT
Indoor
Outdoor
Timer remote controller
Cooling capacity
Nominal (Min - Max)
EER 1)
Nominal (Min - Max)
Nominal (Min - Max)
SEER 2)
Pdesign
Power input cooling
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Heating capacity
Nominal (Min - Max)
Heating capacity at -7°C 4)
Nominal
Heating capacity at -15°C 4) Nominal
1)
Nominal (Min - Max)
COP
Nominal (Min - Max)
SCOP 5)
Pdesign at -10°C
Power input heating
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Indoor unit
External static pressure 6)
Nominal (Min - Max)
Air volume
Cooling / Heating
Moisture removal volume
Sound pressure level 74
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Sound power level
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Dimensions 8)
HxWxD
Net weight
Outdoor unit
Power source
Recommended fuse
Connection
Current
Cooling
Heating
Air volume
Cooling / Heating
Sound pressure level
Cooling / Heating (Hi)
Sound power level
Cooling / Heating (Hi)
Dimensions
HxWxD
Net weight
Piping connections
Liquid pipe
Gas pipe
Refrigerant loading
R410A
Elevation difference (in/out) 9) Max
Piping length
Min / Max
Precharge length
Max
Additional charge
Operating range
Cooling Min / Max
Heating Min / Max
kW
W/W
W/W
kW
kW
kWh/a
kW
kW
kW
W/W
W/W
kW
kW
kWh/a
Single Phase
6,0 kW
KIT-60PNY1E5A
S-60PN1E5A
U-60PEY1E5
CZ-RTC4
6,0 (2,0 - 7,0)
3,02 (6,15 - 2,38) B
4,7 b
6,0
1,990 (0,325 - 2,940)
444
6,0 (1,8 - 7,0)
4,99
4,20
3,61 (6,55 - 2,89) A
3,8 a
4,8
1,660 (0,275 - 2,420)
1.757
7,1 kW
KIT-71PNY1E5A
S-71PN1E5A
U-71PEY1E5
CZ-RTC4
7,1 (2,0 - 7,7)
2,76 (6,15 - 2,38) D
5,0 b
7,1
2,570 (0,325 - 3,230)
496
7,1 (1,8 - 8,1)
5,08
4,37
3,41 (6,55 - 2,91) B
3,8 a
5,3
2,080 (0,275 - 2,780)
1.952
10,0 kW
KIT-100PNY1E5A
S-100PN1E5A
U-100PEY1E5
CZ-RTC4
10,0 (2,7 - 11,5)
2,81 (4,74 - 2,67) C
5,3 a
10,0
3,555 (0,570 - 4,300)
660
10,0 (2,1 - 13,8)
9,97
8,43
3,41 (4,67 - 3,37) B
3,8 a
7,6
2,935 (0,450 - 4,100)
2.800
12,5 kW
KIT-125PNY1E5A
S-125PN1E5A
U-125PEY1E5
CZ-RTC4
12,5 (3,8 - 13,5)
2,81 (4,00 - 2,60) C
—
—
4,445 (0,950 - 5,200)
—
12,5 (3,4 - 15,0)
10,97
9,03
3,41 (4,36 - 3,26) B
—
—
3,665 (0,780 - 4,600)
—
Three Phase
10,0 kW
KIT-100PNY1E8A
S-100PN1E5A
U-100PEY1E8
CZ-RTC4
10,0 (2,7 - 11,5)
2,81 (4,74 - 2,67) C
5,2 a
10,0
3,555 (0,570 - 4,300)
673
10,0 (2,1 - 13,8)
9,97
8,43
3,41 (4,67 - 3,37) B
3,8 a
7,6
2,935 (0,450 - 4,100)
2.800
12,5 kW
KIT-125PNY1E8A
S-125PN1E5A
U-125PEY1E8
CZ-RTC4
12,5 (3,8 - 13,5)
2,81 (4,00 - 2,60) C
—
—
4,445 (0,950 - 5,200)
—
12,5 (3,4 - 15,0)
10,97
9,03
3,41 (4,36 - 3,26) B
—
—
3,665 (0,780 - 4,600)
—
14,0 kW
KIT-140PNY1E8A
S-140PN1E5A
U-140PEY1E8
CZ-RTC4
14,0 (3,3 - 15,5)
2,98 (3,93 - 2,58) C
—
—
4,700 (0,840 - 6,000)
—
14,0 (4,1 - 16,0)
13,35
12,38
3,52 (4,56 - 3,08) B
—
—
3,880 (1,050 - 5,400)
—
Pa
m³/h
l/h
dB(A)
dB(A)
dB
dB
mm
kg
50 (10 - 80)
1.320 / 1.320
3,4
43 / 41 / 36
43 / 41 / 36
60 / 58 / 53
60 / 58 / 53
250 x 1.000(+100) x 650
32
50 (10 - 80)
1.320 / 1.320
4,2
43 / 41 / 36
43 / 41 / 36
60 / 58 / 53
60 / 58 / 53
250 x 1.000(+100) x 650
32
50 (10 - 80)
2.160 / 2.160
6,0
44 / 42 / 37
44 / 42 / 37
65 / 63 / 58
65 / 63 / 58
250 x 1.200(+100) x 650
41
50 (10 - 80)
2.280 / 2.280
7,9
45 / 43 / 38
45 / 43 / 38
66 / 64 / 59
66 / 64 / 59
250 x 1.200(+100) x 650
41
50 (10 - 80)
2.160 / 2.160
6,0
44 / 42 / 37
44 / 42 / 37
65 / 63 / 58
65 / 63 / 58
250 x 1.200(+100) x 650
41
50 (10 - 80)
2.280 / 2.280
7,9
45 / 43 / 38
45 / 43 / 38
66 / 64 / 59
66 / 64 / 59
250 x 1.200(+100) x 650
41
50 (10 - 80)
2.400 / 2.400
9,0
46 / 44 / 39
46 / 44 / 39
67 / 65 / 60
67 / 65 / 60
250 x 1.200(+100) x 650
41
V
A
mm²
A
A
m³/h
dB(A)
dB
mm
kg
Inch (mm)
Inch (mm)
kg
m
m
m
g/m
°C
°C
220 / 230 / 240
20
2,5
9,1 / 8,7 / 8,4
7,5 / 7,2 / 6,9
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
3/8 (9,52)
5/8 (15,88)
1,7
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
20
2,5
12,0 / 11,5 / 11,0
9,6 / 9,2 / 8,9
2.340
50 / 52
70 / 70
569 x 790 x 285
42
3/8 (9,52)
5/8 (15,88)
1,7
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
25
4
16,0 / 15,3 / 14,8
13,0 / 12,5 / 12,1
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340
73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
220 / 230 / 240
30
6
20,1 / 19,3 / 18,7
16,5 / 15,8 / 15,2
4.800 / 4.380
56 / 56
73 / 73
996 x 940 x 340
85
3/8 (9,52)
5/8 (15,88)
3,20
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
5,45 / 5,20 / 5,05
4,45 / 4,25 / 4,10
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340
73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
6,85 / 6,50 / 6,25
5,55 / 5,30 / 5,10
4.800 / 4.380
56 / 56
73 / 73
996 x 940 x 340
85
3/8 (9,52)
5/8 (15,88)
3,20
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
7,05 / 6,70 / 6,45
5,90 / 5,60 / 5,40
8.100 / 7.200
54 / 53
71 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 50
30
50
-10 / +43
-15 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50,
EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal
temperatures are taken at 27°C DB and 19°C WB. 3) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 4) Heating capacity is calculated including defrost factor correction. 5) SCOP is calculated in base Eurovent IPLV for SBEM with U1
STANDARD
Internet
Energy
5,30 A
SEER
SCOP
N
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-100PNY1E5A.
38
3,80 A
AL
saving
OP
TIO
Control
Ready
SEASONAL COEFFICIENT
OF PERFORMANCE
Down to
Down to
-10°C in
-15°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-60PEY1E5
U-71PEY1E5
U-100PEY1E5 U-100PEY1E8
U-125PEY1E5 U-125PEY1E8
U-140PEY1E8
NEW __ COMMERCIAL
HIGH
HEATING
CAPACIT Y
AT -7°C
Optional Controller
Wired remote controller
CZ-RTC5
Optional Controller
Timer remote controller
CZ-RTC4
Optional Controller
Wireless remote controller
CZ-RWSK2 + CZ-RWSC3
Optional Controller
Simplified remote controller
CZ-RE2C2
Compatible with all Panasonic connectivity solutions. For detailed information go to the Control Systems section.
ELITE
Single Phase
5,0 kW
KIT-50PN1E5A
S-50PN1E5A
U-50PE1E5
CZ-RTC4
5,0 (1,5 - 5,6)
3,21 (5,77 - 2,42) A
4,6 b
5,0
1,560 (0,260 - 2,310)
380
5,6 (1,5 - 6,3)
4,20
3,58
3,22 (6,82 - 2,50) C
3,8 a
3,8
1,740 (0,220 - 2,520)
1.400
6,0 kW
KIT-60PN1E5A
S-60PN1E5A
U-60PE1E5A
CZ-RTC4
6,0 (2,5 - 7,1)
3,24 (4,55 - 3,37) A
5,5 a
6,0
1,850 (0,550 - 2,105)
382
7,0 (2,0 - 8,0)
6,69
6,56
3,61 (4,00 - 3,09) A
3,8 a
5,6
1,940 (0,500 - 2,585)
2.061
7,1 kW
KIT-71PN1E5A
S-71PN1E5A
U-71PE1E5A
CZ-RTC4
7,1 (2,5 - 8,0)
3,30 (4,55 - 2,91) A
5,5 a
7,1
2,150 (0,550 - 2,750)
452
8,0 (2,0 - 9,0)
7,52
7,65
3,54 (4,00 - 3,08) B
3,7 a
6,5
2,260 (0,500 - 2,920)
2.458
10,0 kW
KIT-100PN1E5A
S-100PN1E5A
U-100PE1E5A
CZ-RTC4
10,0 (3,3 - 12,5)
3,75 (3,79 - 3,29) A
6,0 h
10,0
2,670 (0,870 - 3,800)
583
11,2 (4,1 - 14,0)
12,04
11,20
3,80 (4,18 - 3,11) A
3,9 a
10,0
2,950 (0,980 - 4,500)
3.590
12,5 kW
KIT-125PN1E5A
S-125PN1E5A
U-125PE1E5A
CZ-RTC4
12,5 (3,3 - 14,0)
3,21 (3,30 - 2,92) A
—
—
3,890 (1,000 - 4,800)
—
14,0 (4,1 - 16,0)
13,48
12,38
3,61 (3,90 - 2,96) A
—
—
3,880 (1,050 - 5,400)
—
14,0 kW
KIT-140PN1E5A
S-140PN1E5A
U-140PE1E5A
CZ-RTC4
14,0 (3,3 - 15,5)
3,01 (3,30 - 2,50) B
—
—
4,650 (1,000 - 6,200)
—
16,0 (4,1 - 18,0)
14,24
12,69
3,41 (3,90 - 2,95) B
—
—
4,690 (1,050 - 6,100)
—
Three Phase
7,1 kW
KIT-71PN1E8A
S-71PN1E5A
U-71PE1E8A
CZ-RTC4
7,1 (2,5 - 8,0)
3,30 (3,79 - 2,91) A
5,2 a
7,1
2,150 (0,660 - 2,750)
477
8,0 (2,0 - 9,0)
7,52
7,65
3,54 (3,33 - 3,00) B
3,7 a
6,5
2,260 (0,600 - 3,000)
2.458
10,0 kW
KIT-100PN1E8A
S-100PN1E5A
U-100PE1E8A
CZ-RTC4
10,0 (3,3 - 12,5)
3,75 (3,79 - 3,29) A
5,8 h
10,0
2,670 (0,870 - 3,800)
603
11,2 (4,1 - 14,0)
12,04
11,20
3,80 (4,18 - 3,11) A
3,8 a
10,0
2,950 (0,980 - 4,500)
3.684
12,5 kW
KIT-125PN1E8A
S-125PN1E5A
U-125PE1E8A
CZ-RTC4
12,5 (3,3 - 14,0)
3,21 (3,30 - 2,92) A
—
—
3,890 (1,000 - 4,800)
—
14,0 (4,1 - 16,0)
13,48
12,38
3,61 (3,90 - 2,96) A
—
—
3,880 (1,050 - 5,400)
—
14,0 kW
KIT-140PN1E8A
S-140PN1E5A
U-140PE1E8A
CZ-RTC4
14,0 (3,3 - 15,5)
3,01 (3,30 - 2,50) A
—
—
4,650 (1,000 - 6,200)
—
16,0 (4,1 - 18,0)
14,24
12,69
3,41 (3,90 - 2,95) B
—
—
4,690 (1,050 - 6,100)
—
50 (10 - 80)
960 / 960
2,8
41 / 39 / 35
41 / 39 / 35
58 / 56 / 52
58 / 56 / 52
250x780(+100)x650
29
50 (10 - 80)
1.320 / 1.320
3,4
43 / 41 / 36
43 / 41 / 36
60 / 58 / 53
60 / 58 / 53
250x1.000(+100)x650
32
50 (10 - 80)
1.320 / 1.320
4,2
43 / 41 / 36
43 / 41 / 36
60 / 58 / 53
60 / 58 / 53
250x1.000(+100)x650
32
50 (10 - 80)
2.160 / 2.160
6,0
44 / 42 / 37
44 / 42 / 37
65 / 63 / 58
65 / 63 / 58
250x1.200(+100)x650
41
50 (10 - 80)
2.280 / 2.280
7,9
45 / 43 / 38
45 / 43 / 38
66 / 64 / 59
66 / 64 / 59
250x1.200(+100)x650
41
50 (10 - 80)
2.400 / 2.400
9,0
46 / 44 / 39
46 / 44 / 39
67 / 65 / 60
67 / 65 / 60
250x1.200(+100)x650
41
50 (10 - 80)
1.320 / 1.320
4,2
43 / 41 / 36
43 / 41 / 36
60 / 58 / 53
60 / 58 / 53
250x1.000(+100)x650
32
50 (10 - 80)
2.160 / 2.160
6,0
44 / 42 / 37
44 / 42 / 37
65 / 63 / 58
65 / 63 / 58
250x1.200(+100)x650
41
50 (10 - 80)
2.280 / 2.280
7,9
45 / 43 / 38
45 / 43 / 38
66 / 64 / 59
66 / 64 / 59
250x1.200(+100)x650
41
50 (10 - 80)
2.400 / 2.400
9,0
46 / 44 / 39
46 / 44 / 39
67 / 65 / 60
67 / 65 / 60
250x1.200(+100)x650
41
220 / 230 / 240
16
2,5
7,10 / 6,80 / 6,60
8,00 / 7,70 / 7,40
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
1/4 (6,35)
1/2 (12,7)
1,65
30
5 - 40
30
20
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
8,20 / 8,00 / 7,80
8,60 / 8,40 / 8,20
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
68
3/8 (9,52)
5/8 (15,88)
2
30
5 - 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
9,70 / 9,40 / 9,20
10,2 / 9,90 / 9,70
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
69
3/8 (9,52)
5/8 (15,88)
2,35
30
5 - 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
25
4
11,6 / 11,2 / 10,9
12,8 / 12,5 / 12,2
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 - 75
30
50
-15 / +46
-20 / +24
220 / 230 / 240
30
6
17,4 / 16,9 / 16,4
17,3 / 16,8 / 16,3
7.800 / 6.600
53 / 53
70 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 - 75
30
50
-15 / +46
-20 / +24
220 / 230 / 240
16
2,5
20,5 / 20,1 / 19,5
20,6 / 20,2 / 19,6
8.100 / 7.200
54 / 55
71 / 71
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 - 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
3,25 / 3,10 / 3,00
3,35 / 3,20 / 3,10
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
71
3/8 (9,52)
5/8 (15,88)
2,35
30
5 - 50
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
3,95 / 3,75 / 3,60
4,35 / 4,15 / 4,00
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 - 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
5,80 / 5,50 / 5,30
5,80 / 5,50 / 5,30
7.800 / 6.600
53 / 53
70 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 - 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
6,95 / 6,60 / 6,35
7,00 / 6,65 / 6,45
8.100 / 7.200
54 / 55
71 / 71
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 - 75
30
50
-15 / +46
-20 / +24
indoor unit including defrost correction factor. 6) Medium External static pressure setting from factory. 7) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1,5 m from the ground. The sound pressure is
measured in accordance with Eurovent 6/C/006-97 specification. 8) Add 100 mm for piping port. 9) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A.
For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
ELITE
Internet
Energy
6,00 A+
SEER
3,90 A
SCOP
N
AL
saving
OP
TIO
Control
Ready
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-100PN1E5A.
SEASONAL COEFFICIENT
OF PERFORMANCE
Down to
Down to
-15°C in
-20°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-50PE1E5
U-60PE1E5A
U-71PE1E5A
U-71PE1E8A
U-100PE1E5A U-100PE1E8A
U-125PE1E5A U-125PE1E8A
U-140PE1E5A U-140PE1E8A
39
The ducted systems are the ideal solution for
flexible, concealed air conditioning and the optional
200mm spigots ensure simple, hassle-free
connection to spiral ductwork.
HIGH STATIC PRESSURE
HIDE AWAY
PACi STANDARD AND ELITE
INVERTER+
Technical Focus
· Extremely quiet operation from 26 dB(A)
· Auto restart after power failure
· Auto changeover
· Twin, triple and double-twin split options
· DC FAN for better efficiency and control
· Built in drain pump
· Easy connection and control of external fan or ERV using
the connector PAW-FDC on the indoor unit PCB. The
external device can be control by the remote control of the
Panasonic indoor unit
STANDARD
KIT
Indoor
Outdoor
Timer remote controller
Cooling capacity
Nominal (Min - Max)
EER 1)
Nominal (Min - Max)
Nominal (Min - Max)
SEER 2)
Pdesign
Power input cooling
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Heating capacity
Nominal (Min - Max)
Heating capacity at -7°C 4)
Nominal
Heating capacity at -15°C 4) Nominal
1)
Nominal (Min - Max)
COP
SCOP 5)
Nominal (Min - Max)
Pdesign at -10°C
Power input heating
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Indoor unit
External static pressure 6)
Nominal (Min - Max)
Air volume
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Moisture removal volume
Sound pressure level 7)
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Sound power level
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Dimensions
HxWxD
Net weight
Outdoor unit
Power source
Recommended fuse
Connection
Current
Cooling
Heating
Air volume
Cooling / Heating
Sound pressure level
Cooling / Heating (Hi)
Sound power level
Cooling / Heating (Hi)
Dimensions
HxWxD
Net weight
Piping connections
Liquid pipe
Gas pipe
Refrigerant loading
R410A
Elevation difference (in/out) 8) Max
Piping length
Min / Max
Precharge length
Max
Additional charge
Operating range
Cooling Min / Max
Heating Min / Max
kW
W/W
W/W
kW
kW
kWh/a
kW
kW
kW
W/W
W/W
kW
kW
kWh/a
Single Phase
6,0 kW
KIT-60PFY1E5A
S-60PF1E5A
U-60PEY1E5
CZ-RTC4
6,0 (2,0 - 7,0)
3,10 (6,15 - 2,46) B
5,4 a
6,0
1,930 (0,325 - 2,850)
389
6,0 (1,8 - 7,0)
4,99
4,20
4,25 (6,55 - 3,41) A
3,8 a
5,0
1,410 (0,275 - 2,055)
1.842
7,1 kW
KIT-71PFY1E5A
S-71PF1E5A
U-71PEY1E5
CZ-RTC4
7,1 (2,0 - 7,7)
2,76 (6,15 - 2,35) D
5,3 a
7,1
2,570 (0,325 - 3,270)
469
7,1 (1,8 - 8,1)
5,08
4,37
3,94 (6,55 - 3,40) A
3,8 a
5,5
1,800 (0,275 - 2,380)
2.026
10,0 kW
KIT-100PFY1E5A
S-100PF1E5A
U-100PEY1E5
CZ-RTC4
10,0 (2,7 - 11,5)
3,01 (5,09 - 2,74) B
5,4 a
10,0
3,320 (0,530 - 4,200)
648
10,0 (2,1 - 13,8)
9,97
8,43
3,80 (5,12 - 3,45) A
3,8 a
9,5
2,630 (0,410 - 4,000)
3.500
12,5 kW
KIT-125PFY1E5A
S-125PF1E5A
U-125PEY1E5
CZ-RTC4
12,5 (3,8 - 13,5)
3,05 (4,22 - 2,70) B
—
—
4,100 (0,900 - 5,000)
—
12,5 (3,4 - 15,0)
10,97
9,03
3,82 (4,66 - 3,41) A
—
—
3,270 (0,730 - 4,400)
—
Three Phase
10,0 kW
KIT-100PFY1E8A
S-100PF1E5A
U-100PEY1E8
CZ-RTC4
10,0 (2,7 - 11,5)
3,01 (5,09 - 2,74) B
5,2 a
10,0
3,320 (0,530 - 4,200)
673
10,0 (2,1 - 13,8)
9,97
8,43
3,80 (5,12 - 3,45) A
3,8 a
9,5
2,630 (0,410 - 4,000)
3.500
12,5 kW
KIT-125PFY1E8A
S-125PF1E5A
U-125PEY1E8
CZ-RTC4
12,5 (3,8 - 13,5)
3,05 (4,22 - 2,70) B
—
—
4,100 (0,900 - 5,000)
—
12,5 (3,4 - 15,0)
10,97
9,03
3,82 (4,66 - 3,41) A
—
—
3,270 (0,730 - 4,400)
—
14,0 kW
KIT-140PFY1E8A
S-140PF1E5A
U-140PEY1E8
CZ-RTC4
14,0 (3,3 - 15,5)
3,22 (3,93 - 2,58) A
—
—
4,350 (0,840 - 6,000)
—
14,0 (4,1 - 16,0)
13,35
12,38
3,91 (4,56 - 3,08) A
—
—
3,580 (0,900 - 5,200)
—
Pa
m³/h
m³/h
l/h
dB(A)
dB(A)
dB
dB
mm
kg
70 (10 - 150)
1.260 / 1.140 / 900
1.260 / 1.140 / 900
3,4
35 / 32 / 26
35 / 32 / 26
57 / 54 / 48
57 / 54 / 48
290 x 1.000 x 700
33
70 (10 - 150)
1.260 / 1.140 / 900
1.260 / 1.140 / 900
4,2
35 / 32 / 26
35 / 32 / 26
57 / 54 / 48
57 / 54 / 48
290 x 1.000 x 700
33
100 (10 - 150)
1.920 / 1.560 / 1.260
1.920 / 1.560 / 1.260
6,0
38 / 34 / 31
38 / 34 / 31
60 / 56 / 53
60 / 56 / 53
290 x 1.400 x 700
45
100 (10 - 150)
2.040 / 1.740 / 1.380
2.040 / 1.740 / 1.380
7,9
39 / 35 / 32
39 / 35 / 32
61 / 57 / 54
61 / 57 / 54
290 x 1.400 x 700
45
100 (10 - 150)
1.920 / 1.560 / 1.260
1.920 / 1.560 / 1.260
6,0
38 / 34 / 31
38 / 34 / 31
60 / 56 / 53
60 / 56 / 53
290 x 1.400 x 700
45
100 (10 - 150)
2.040 / 1.740 / 1.380
2.040 / 1.740 / 1.380
7,9
39 / 35 / 32
39 / 35 / 32
61 / 57 / 54
61 / 57 / 54
290 x 1.400 x 700
45
100 (10 - 150)
2.160 / 1.920 / 1.500
2.160 / 1.920 / 1.500
9,0
40 / 36 / 33
40 / 36 / 33
62 / 58 / 55
62 / 58 / 55
290 x 1.400 x 700
45
V
A
mm²
A
A
m³/h
dB(A)
dB
mm
kg
Inch (mm)
Inch (mm)
kg
m
m
m
g/m
°C
°C
220 / 230 / 240
20
2,5
9,00 / 8,65 / 8,30
6,40 / 6,10 / 5,90
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
3/8 (9,52)
5/8 (15,88)
1,7
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
20
2,5
12,2 / 11,7 / 11,2
8,30 / 7,90 / 7,60
2.340 / 2.340
50 / 52
70 / 70
569 x 790 x 285
42
3/8 (9,52)
5/8 (15,88)
1,7
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
25
4
15,1 / 14,5 / 13,9
11,8 / 11,2 / 10,7
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340
73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
220 / 230 / 240
30
6
18,8 / 18,0 / 17,2
14,6 / 14,0 / 13,4
4.800 / 4.380
56 / 56
73 / 73
996 x 940 x 340
85
3/8 (9,52)
5/8 (15,88)
3,20
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
5,10 / 4,85 / 4,70
4,05 / 3,80 / 3,65
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340
73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
6,20 / 5,90 / 5,70
4,90 / 4,65 / 4,50
4.800 / 4.380
56 / 56
73 / 73
996 x 940 x 340
85
3/8 (9,52)
5/8 (15,88)
3,20
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
6,75 / 6,45 / 6,25
5,60 / 5,40 / 5,20
8.100 / 7.200
54 / 53
71 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 50
30
50
-10 / +43
-15 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50,
EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal
temperatures are taken at 27°C DB and 19°C WB. 3) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 4) Heating capacity is calculated including defrost factor correction. 5) SCOP is calculated in base Eurovent IPLV for SBEM with U1
STANDARD
Internet
Energy
5,40 A
SEER
3,80 A
SCOP
N
AL
saving
OP
TIO
Control
Ready
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
SEASONAL COEFFICIENT
OF PERFORMANCE
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-60PFY1E5A and KIT-100PFY1E5A.
40
Down to
Down to
-10°C in
-15°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-60PEY1E5
U-71PEY1E5
U-100PEY1E5 U-100PEY1E8
U-125PEY1E5 U-125PEY1E8
U-140PEY1E8
NEW __ COMMERCIAL
HIGH
HEATING
CAPACIT Y
AT -7°C
S-100PF1E5A // S-125PF1E5A // S-140PF1E5A
Optional Controller
Wired remote controller
CZ-RTC5
Optional Controller
Timer remote controller
CZ-RTC4
Optional Controller
Wireless remote controller
CZ-RWSK2 + CZ-RWSC3
Optional Controller
Simplified remote controller
CZ-RE2C2
Air Outlet Plenum (without regulation adaptor)
Diameters Model
60 & 71
3 x Ø 200 CZ-90DAF2
100, 125 & 140
4 x Ø 200 CZ-160DAF2
Air Inlet Plenum
60 & 71
100, 125 & 140
Diameters Model
2 x Ø 250 CZ-DUMPA90MF2
4 x Ø 200 CZ-DUMPA160MF2
Compatible with all Panasonic connectivity solutions. For detailed information go to the Control Systems section.
ELITE
Single Phase
5,0 kW
KIT-50PF1E5A
S-50PF1E5A
U-50PE1E5
CZ-RTC4
5,0 (1,5 - 5,6)
3,77 (5,58 - 2,80) A
5,7 h
5,0
1,350 (0,260 - 2,000)
307
5,6 (1,5 - 6,5)
4,20
3,58
3,73 (6,82 - 2,71) A
3,8 a
4,0
1,500 (0,220 - 2,400)
1.474
6,0 kW
KIT-60PF1E5A
S-60PF1E5A
U-60PE1E5A
CZ-RTC4
6,0 (2,5 - 7,1)
3,90 (4,72 - 3,55) A
6,4 i
6,0
1,540 (0,530 - 2,000)
328
7,0 (2,0 - 8,0)
6,69
6,56
3,87 (4,17 - 3,23) A
3,9 a
6,0
1,810 (0,480 - 2,480)
2.154
7,1 kW
KIT-71PF1E5A
S-71PF1E5A
U-71PE1E5A
CZ-RTC4
7,1 (2,5 - 8,0)
3,84 (4,72 - 3,02) A
6,4 i
7,1
1,850 (0,530 - 2,650)
388
8,0 (2,0 - 9,0)
7,52
7,65
3,85 (4,17 - 3,10) A
4,0 h
7,1
2,080 (0,480 - 2,900)
2.485
10,0 kW
KIT-100PF1E5A
S-100PF1E5A
U-100PE1E5A
CZ-RTC4
10,0 (3,3 - 12,5)
4,10 (3,93 - 3,38) A
5,8 h
10,0
2,440 (0,840 - 3,700)
603
11,2 (4,1 - 14,0)
12,04
11,20
4,31 (4,56 - 3,18) A
3,8 a
10,0
2,600 (0,900 - 4,400)
3.684
12,5 kW
KIT-125PF1E5A
S-125PF1E5A
U-125PE1E5A
CZ-RTC4
12,5 (3,3 - 14,0)
3,50 (3,93 - 3,04) A
—
—
3,570 (0,840 - 4,600)
—
14,0 (4,1 - 16,0)
13,48
12,38
4,02 (4,56 - 3,08) A
—
—
3,480 (0,900 - 5,200)
—
14,0 kW
KIT-140PF1E5A
S-140PF1E5A
U-140PE1E5A
CZ-RTC4
14,0 (3,3 - 15,5)
3,25 (3,93 - 2,58) A
—
—
4,310 (0,840 - 6,000)
—
16,0 (4,1 - 18,0)
14,24
12,69
3,60 (4,56 - 3,05) A
—
—
4,440 (0,900 - 5,900)
—
Three Phase
7,1 kW
KIT-71PF1E8A
S-71PF1E5A
U-71PE1E8A
CZ-RTC4
7,1 (3,2 - 8,0)
3,84 (5,0 - 3,02) A
6,0 a
7,1
1,850 (0,640 - 2,650)
414
8,0 (2,8 - 9,0)
7,52
7,65
3,85 (4,83 - 3,10) A
3,9 a
7,1
2,080 (0,580 - 2,900)
2.548
10,0 kW
KIT-100PF1E8A
S-100PF1E5A
U-100PE1E8A
CZ-RTC4
10,0 (3,3 - 12,5)
4,10 (3,93 - 3,38) A
5,7 h
10,0
2,440 (0,840 - 3,700)
614
11,2 (4,1 - 14,0)
12,04
11,20
4,31 (4,56 - 3,18) A
3,8 a
10,0
2,600 (0,900 - 4,400)
3.684
12,5 kW
KIT-125PF1E8A
S-125PF1E5A
U-125PE1E8A
CZ-RTC4
12,5 (3,3 - 14,0)
3,50 (3,93 - 3,04) A
—
—
3,570 (0,840 - 4,600)
—
14,0 (4,1 - 16,0)
13,48
12,38
4,02 (4,56 - 3,08) A
—
—
3,480 (0,900 - 5,200)
—
14,0 kW
KIT-140PF1E8A
S-140PF1E5A
U-140PE1E8A
CZ-RTC4
14,0 (3,3 - 15,5)
3,25 (3,93 - 2,58) A
—
—
4,310 (0,840 - 6,000)
—
16,0 (4,1 - 18,0)
14,24
12,69
3,60 (4,56 - 3,05) A
—
—
4,440 (0,900 - 5,900)
—
70 (10 - 150)
960 / 900 / 720
960 / 900 / 720
2,8
34 / 30 / 26
34 / 30 / 26
56 / 52 / 48
56 / 52 / 48
290 x 800 x 700
28
70 (10 - 150)
1.260 / 1.140 / 900
1.260 / 1.140 / 900
3,4
35 / 32 / 26
35 / 32 / 26
57 / 54 / 48
57 / 54 / 48
290 x 1.000 x 700
33
70 (10 - 150)
1.260 / 1.140 / 900
1.260 / 1.140 / 900
4,2
35 / 32 / 26
35 / 32 / 26
57 / 54 / 48
57 / 54 / 48
290 x 1.000 x 700
33
100 (10 - 150)
1.920 / 1.560 / 1.260
1.920 / 1.560 / 1.260
6,0
38 / 34 / 31
38 / 34 / 31
60 / 56 / 53
60 / 56 / 53
290 x 1.400 x 700
45
100 (10 - 150)
2.040 / 1.740 / 1.380
2.040 / 1.740 / 1.380
7,9
39 / 35 / 32
39 / 35 / 32
61 / 57 / 54
61 / 57 / 54
290 x 1.400 x 700
45
100 (10 - 150)
2.160 / 1.920 / 1.500
2.160 / 1.920 / 1.500
9,0
40 / 36 / 33
40 / 36 / 33
62 / 58 / 55
62 / 58 / 55
290 x 1.400 x 700
45
70 (10 - 150)
1.260 / 1.140 / 900
1.260 / 1.140 / 900
4,2
35 / 32 / 26
35 / 32 / 26
57 / 54 / 48
57 / 54 / 48
290 x 1.000 x 700
33
100 (10 - 150)
1.920 / 1.560 / 1.260
1.920 / 1.560 / 1.260
6,0
38 / 34 / 31
38 / 34 / 31
60 / 56 / 53
60 / 56 / 53
290 x 1.400 x 700
45
100 (10 - 150)
2.040 / 1.740 / 1.380
2.040 / 1.740 / 1.380
7,9
39 / 35 / 32
39 / 35 / 32
61 / 57 / 54
61 / 57 / 54
290 x 1.400 x 700
45
100 (10 - 150)
2.160 / 1.920 / 1.500
2.160 / 1.920 / 1.500
9,0
40 / 36 / 33
40 / 36 / 33
62 / 58 / 55
62 / 58 / 55
290 x 1.400 x 700
45
220 / 230 / 240
16
2,5
6,10 / 5,85 / 5,60
6,85 / 6,55 / 6,25
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
1/4 (6,35)
1/2 (12,7)
1,65
30
5 / 40
30
20
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
7,70 / 7,40 / 7,10
8,70 / 8,40 / 8,10
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
68
3/8 (9,52)
5/8 (15,88)
2
30
5 / 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
8,90 / 8,60 / 8,30
9,90 / 9,50 / 9,20
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
69
3/8 (9,52)
5/8 (15,88)
2,35
30
5 / 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
25
4
11,0 / 10,6 / 10,3
11,6 / 11,2 / 10,7
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
220 / 230 / 240
30
6
16,6 / 15,9 / 15,3
16,3 / 15,8 / 15,1
7.800 / 6.600
53 / 53
70 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
220 / 230 / 240
16
2,5
20,1 / 19,3 / 18,6
19,9 / 19,1 / 18,4
8.100 / 7.200
54 / 55
71 / 71
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
2,75 / 2,65 / 2,60
3,10 / 3,00 / 2,90
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
71
3/8 (9,52)
5/8 (15,88)
2,35
30
5 / 50
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
3,68 / 3,53 / 3,43
3,86 / 3,70 / 3,58
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
5,52 / 5,29 / 5,12
5,44 / 5,26 / 5,05
7.800 / 6.600
53 / 53
70 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
6,69 / 6,42 / 6,18
6,64 / 6,35 / 6,15
8.100 / 7.200
54 / 55
71 / 71
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
30
50
-15 / +46
-20 / +24
indoor unit including defrost correction factor. 6) Medium External static pressure setting from factory. 7) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1,5 m from the ground. The sound pressure is
measured in accordance with Eurovent 6/C/006-97 specification. 8) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A.
For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
ELITE
Internet
Energy
6,40 A++
SEER
4,00 A+
SCOP*
N
AL
saving
OP
TIO
Control
Ready
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-71PF1E5A.
SEASONAL COEFFICIENT
OF PERFORMANCE
Down to
Down to
-15°C in
-20°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-50PE1E5
U-60PE1E5A
U-71PE1E5A
U-71PE1E8A
U-100PE1E5A U-100PE1E8A
U-125PE1E5A U-125PE1E8A
U-140PE1E5A U-140PE1E8A
41
This range of ceiling mounted units feature a DC fan
motor for increased efficiency and reduced operating
sound levels. All the units are the same height and
depth for a uniform appearance in mixed
installations. A knock out is provided to allow for
supplementary fresh air for improved air quality.
CEILING
PACi STANDARD AND ELITE
INVERTER+
Technical Focus
· Fresh air connection possible (Outside intake duct
connection port of 100mm diameter is available on the unit)
· All units just 235 mm high
· Twin rotary compressor dramatically reduces vibration and
noise during operation
· DC inverter control
· Large and wide air distribution
· Industry-leading low sound levels
· Twin, Triple and Double-twin split options
· Easy connection and control of external fan or ERV using
the connector PAW-FDC on the indoor unit PCB. The
external device can be control by the remote control of the
Panasonic indoor unit
STANDARD
KIT
Indoor
Outdoor
Timer remote controller
Cooling capacity
Nominal (Min - Max)
EER 1)
Nominal (Min - Max)
Nominal (Min - Max)
SEER 2)
Pdesign
Power input cooling
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Heating capacity
Nominal (Min - Max)
Heating capacity at -7°C 4)
Nominal
Heating capacity at -15°C 4) Nominal
1)
Nominal (Min - Max)
COP
Nominal (Min - Max)
SCOP 5)
Pdesign at -10°C
Power input heating
Nominal (Min - Max)
Annual energy consumption (ErP) 3)
Indoor unit
Air volume
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Moisture removal volume
Sound pressure level 6)
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Sound power level
Cooling (Hi / Med / Lo)
Heating (Hi / Med / Lo)
Dimensions
HxWxD
Net weight
Outdoor unit
Power source
Recommended fuse
Connection
Current
Cooling
Heating
Air volume
Cooling / Heating
Sound pressure level
Cooling / Heating (Hi)
Sound power level
Cooling / Heating (Hi)
Dimensions
HxWxD
Net weight
Piping connections
Liquid pipe
Gas pipe
Refrigerant loading
R410A
Elevation difference (in/out) 7) Max
Piping length
Min / Max
Precharge length
Max
Additional charge
Operating range
Cooling Min / Max
Heating Min / Max
Single Phase
6,0 kW
KIT-60PTY2E5A
S-60PT2E5A
U-60PEY1E5
CZ-RTC4
6,0 (2,0 - 7,0)
3,61 (6,15 - 2,80) A
6,7 i
6,0
1,660 (0,325 - 2,500)
314
6,0 (1,8 - 7,0)
4,99
4,20
4,20 A (6,55 - 3,25)
4,0 h
6,0
1,430 (0,275 - 2,155)
2.100
7,1 kW
KIT-71PTY2E5A
S-71PT2E5A
U-71PEY1E5
CZ-RTC4
7,1 (2,2 - 7,7)
3,21 (6,15 - 2,73) A
6,1 i
7,1
2,210 (0,325 - 2,820)
408
7,1 (1,8 - 8,1)
5,08
4,37
3,90 (6,55 - 3,23) A
4,0 h
6,0
1,820 (0,275 - 2,510)
2.100
10,0 kW
KIT-100PTY2E5A
S-100PT2E5A
U-100PEY1E5
CZ-RTC4
10,0 (2,7 - 11,5)
3,01(5,09 - 2,65) B
6,1 i
10,0
3,320 (0,530 - 4,340)
574
10,0 (2,1 - 13,8)
9,97
8,43
3,85 (5,12 - 3,45) A
3,9 a
10,0
2,600 (0,410 - 4,000)
3.590
12,5 kW
KIT-125PTY2E5A
S-125PT2E5A
U-125PEY1E5
CZ-RTC4
12,5 (3,8 - 13,5)
3,01 (4,22 - 2,62) B
—
—
4,150 (0,900 - 5,160)
—
12,5 (3,4 - 15,0)
10,97
9,03
3,85 (4,66 - 3,41) A
3,40 4)
—
3,250 (0,730 - 4,400)
Three Phase
10,0 kW
KIT-100PTY2E8A
S-100PT2E5A
U-100PEY1E8
CZ-RTC4
10,0 (2,7 - 11,5)
3,01 (5,09 - 2,65) B
6,0 h
10,0
3,320 (0,530 - 4,340)
584
10,0 (2,1 - 13,8)
9,97
8,43
3,85 (5,12 - 3,45) A
3,9 a
10,0
2,600 (0,410 - 4,000)
3.590
12,5 kW
KIT-125PTY2E8A
S-125PT2E5A
U-125PEY1E8
CZ-RTC4
12,5 (3,8 - 13,5)
3,01 (4,22 - 2,62) B
—
—
4,150 (0,900 - 5,160)
—
12,5 (3,4 - 15,0)
10,97
9,03
3,85 (4,66 - 3,41) A
3,40 4)
—
3,250 (0,730 - 4,400)
14,0 kW
KIP-140PTY2E8A
S-140PT2E5A
U-140PEY1E8
CZ-RTC4
14,0 (3,3 - 15,0)
2,98 (3,93 - 2,63) C
—
—
4,700 (0,840 - 5,700)
—
14,0 (4,1 - 16,0)
13,35
12,38
3,88 (4,56 - 3,07) A
3,52 4)
—
3,610 ( 0,900 - 5,210)
—
l/h
dB(A)
dB(A)
dB
dB
mm
kg
1.200 / 1.020 / 870
1.200 / 1.020 / 870
3,4
38 / 34 / 30
38 / 34 / 30
56 /52 / 48
56 /52 / 48
235 x 1.275 x 690
33
1.260 / 1.080 / 930
1.260 / 1.080 / 930
4,2
39 / 35 / 31
39 / 35 / 31
57 / 53 / 49
57 / 53 / 49
235 x 1.275 x 690
33
1.800 / 1.500 / 1.380
1.800 / 1.500 / 1.380
6,0
42 / 37 / 35
42 / 37 / 35
60 / 55 / 53
60 / 55 / 53
235 x 1.590 x 690
40
2.040 / 1.680 / 1.440
2.040 / 1.680 / 1.440
7,9
46 / 40 / 36
46 / 40 / 36
64 / 58 / 54
64 / 58 / 54
235 x 1.590 x 690
40
1.800 / 1.500 / 1.380
1.800 / 1.500 / 1.380
6,0
42 / 37 / 35
42 / 37 / 35
60 / 55 / 53
60 / 55 / 53
235 x 1.590 x 690
40
2.040 / 1.680 / 1.440
2.040 / 1.680 / 1.440
7,9
46 / 40 / 36
46 / 40 / 36
64 / 58 / 54
64 / 58 / 54
235 x 1.590 x 690
40
2.100 / 1.740 / 1.500
2.100 / 1.740 / 1.500
9,0
47 / 41 / 37
47 / 41 / 37
65 / 59 / 55
65 / 59 / 55
235 x 1.590 x 690
40
V
A
mm²
A
A
m³/h
dB(A)
dB
mm
kg
Inch (mm)
Inch (mm)
kg
m
m
m
g/m
°C
°C
220 / 230 / 240
20
2,5
8,05 / 7,70 / 7,40
6,90 / 6,60 / 6,30
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
3/8 (9,52)
5/8 (15,88)
1,70
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
20
2,5
10,8 / 10,3 / 9,85
8,75 / 8,35 / 8,00
2.340 / 2.340
50 / 52
70 / 70
569 x 790 x 285
42
3/8 (9,52)
5/8 (15,88)
1,70
30
5 / 50
20
40
-10 / +43
-15 / +24
220 / 230 / 240
25
4
15,6 / 15,0 / 14,4
11,9 / 11,5 / 11,1
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340
73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
220 / 230 / 240
30
6
19,7 / 18,9 / 18,1
15,2 / 14,6 / 13,9
4.800 / 4.380
56 / 56
73 / 73
996 x 940 x 340
85
3/8 (9,52)
5/8 (15,88)
3,20
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
5,30 / 5,05 / 4,85
4,10 / 3,90 / 3,75
4.560 / 4.020
54 / 54
70 / 70
996 x 940 x 340
73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
6,50 / 6,20 / 6,00
5,10 / 4,80 / 4,65
4.800 / 4.380
56 / 56
73 / 73
996 x 940 x 340
85
3/8 (9,52)
5/8 (15,88)
3,20
30
5 / 50
30
50
-10 / +43
-15 / +24
380 / 400 / 415
16
2,5
7,40 / 7,00 / 6,80
5,65 / 5,35 / 5,15
8.100 / 7.200
54 / 53
71 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,40
30
5 / 50
30
50
-10 / +43
-15 / +24
kW
W/W
W/W
kW
kW
kWh/a
kW
kW
kW
W/W
W/W
kW
kW
kWh/a
m³/h
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50,
EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal
temperatures are taken at 27°C DB and 19°C WB. 3) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 4) Heating capacity is calculated including defrost factor correction. 5) SCOP is calculated in base Eurovent IPLV for SBEM with U1
STANDARD
Internet
Energy
6,10 A++
SEER
SCOP
N
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-100PTY2E5A.
42
3,90 A
AL
saving
OP
TIO
Control
Ready
SEASONAL COEFFICIENT
OF PERFORMANCE
Down to
Down to
-10°C in
-15°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-60PEY1E5
U-71PEY1E5
U-100PEY1E5 U-100PEY1E8
U-125PEY1E5 U-125PEY1E8
U-140PEY1E8
NEW __ COMMERCIAL
HIGH
HEATING
CAPACIT Y
AT -7°C
Optional Controller
Wired remote controller
CZ-RTC5
Optional Controller
Timer remote controller
CZ-RTC4
Optional Controller
Wireless remote controller
CZ-RWST3
Optional Controller
Simplified remote controller
CZ-RE2C2
Compatible with all Panasonic connectivity solutions. For detailed information go to the Control Systems section.
ELITE
Single Phase
5,0 kW
KIT-50PT2E5A
S-50PT2E5A
U-50PE1E5
CZ-RTC4
5,0 (1,5 - 5,6)
3,62 (5,77 - 2,73) A
6,4 i
5,0
1,380 (0,260 - 2,050)
273
5,6 (1,5 - 6,5)
4,20
3,58
3,97 (6,82 - 2,83) A
4,0 a
4,0
1,410 (0,220 - 2,300)
1.400
6,0 kW
KIT-60PT2E5A
S-60PT2E5A
U-60PE1E5A
CZ-RTC4
6,0 (2,5 - 7,1)
4,03 (5,56 - 3,53) A
6,8 i
6,0
1,490 (0,450 - 2,010)
309
7,0 (2,0 - 8,0)
6,69
6,56
4,02 (5,00 - 3,23) A
4,1 h
6,0
1,740 (0,400 - 2,480)
2.049
7,1 kW
KIT-71PT2E5A
S-71PT2E5A
U-71PE1E5A
CZ-RTC4
7,1 (2,5 - 8,0)
3,68 (5,56 - 2,88) A
6,2 i
7,1
1,930 (0,450 - 2,780)
965
8,0 (2,0 - 9,0)
7,52
7,65
4,15 (5,00 - 3,10) A
4,0 h
7,1
1,930 (0,400 - 2,900)
2.485
10,0 kW
KIT-100PT2E5A
S-100PT2E5A
U-100PE1E5A
CZ-RTC4
10,0 (3,3 - 12,5)
3,95 (3,93 - 3,25) A
6,7 i
10,0
2,530 (0,840 - 3,850)
523
11,2 (4,1 - 14,0)
12,04
11,20
4,31 (4,56 - 3,18) A
4,3 h
10,0
2,600 (0,900 - 4,400)
3.256
12,5 kW
KIT-125PT2E5A
S-125PT2E5A
U-125PE1E5A
CZ-RTC4
12,5 (3,3 - 14,0)
3,35 (3,93 - 2,88) A
—
—
3,730 (0,840 - 4,860)
—
14,0 (4,1 - 16,0)
13,48
12,38
3,99 (4,56 - 3,07) A
3,63 4)
—
3,510 (0,900 - 5,210)
—
14,0 kW
KIT-140PT2E5A
S-140PT2E5A
U-140PE1E5A
CZ-RTC4
14,0 (3,3 - 15,0)
3,01 (3,93 - 2,65) B
—
—
4,650 (0,840 - 5,650)
—
16,0 (4,1 - 18,0)
14,24
12,69
3,67 (4,56 - 3,04) A
3,41 4)
—
4,360 (0,900 - 5,930)
—
Three Phase
7,1 kW
KIT-71PT2E8A
S-71PT2E5A
U-71PE1E8A
CZ-RTC4
7,1 (2,5 - 8,0)
3,68 (5,56 - 2,88) A
5,9 h
7,1
1,930 (0,450 - 2,780)
421
8,0 (2,0 - 9,0)
7,52
7,65
4,15 (5,00 - 3,10) A
4,0 h
7,1
1,930 ( 0,400 - 2,900)
2.485
10,0 kW
KIT-100PT2E8A
S-100PT2E5A
U-100PE1E8A
CZ-RTC4
10,0 (3,3 - 12,5)
3,95 (3,93 - 3,25) A
6,6 i
10,0
2,530 (0,840 - 3,850)
531
11,2 (4,1 - 14,0)
12,04
11,20
4,31 (4,56 - 3,18) A
4,3 h
10,0
2,600 (0,900 - 4,400)
3.256
12,5 kW
KIT-125PT2E8A
S-125PT2E5A
U-125PE1E8A
CZ-RTC4
12,5 (3,3 - 14,0)
3,35 (3,93 - 2,88) A
—
—
3,730 (0,840 - 4,860)
—
14,0 (4,1 - 16,0)
13,48
12,38
3,99 (4,56 - 3,07) A
3,63 4)
—
3,510 (0,900 - 5,210)
—
14,0 kW
KIT-140PT2E8A
S-140PT2E5A
U-140PE1E8A
CZ-RTC4
14,0 (3,3 - 15,0)
3,01 (3,93 - 2,65) B
—
—
4,650 (0,840 - 5,650)
—
16,0 (4,1 - 18,0)
14,24
12,69
3,67 (4,56 - 3,04) A
3,41 4)
—
4,360 (0,900 - 5,930)
—
900 / 750 / 630
900 / 750 / 630
2,8
37 / 33 / 29
37 / 33 / 29
55 / 51 / 47
55 / 51 / 47
235 x 960 x 690
27
1.200 / 1.020 / 870
1.200 / 1.020 / 870
3,4
38 / 34 / 30
38 / 34 / 30
56 /52 / 48
56 /52 / 48
235 x 1.275 x 690
33
1.260 / 1.080 / 930
1.260 / 1.080 / 930
4,2
39 / 35 / 31
39 / 35 / 31
57 / 53 / 49
57 / 53 / 49
235 x 1.275 x 690
33
1.800 / 1.500 / 1.380
1.800 / 1.500 / 1.380
6,0
42 / 37 / 35
42 / 37 / 35
60 / 55 / 53
60 / 55 / 53
235 x 1.590 x 690
40
2.040 / 1.680 / 1.440
2.040 / 1.680 / 1.440
7,9
46 / 40 / 36
46 / 40 / 36
64 / 58 / 54
64 / 58 / 54
235 x 1.590 x 690
40
2.100 / 1.740 / 1.500
2.100 / 1.740 / 1.500
9,0
47 / 41 / 37
47 / 41 / 37
65 / 59 / 55
65 / 59 / 55
235 x 1.590 x 690
40
1.260 / 1.080 / 930
1.260 / 1.080 / 930
4,2
39 / 35 / 31
39 / 35 / 31
57 / 53 / 49
57 / 53 / 49
235 x 1.275 x 690
33
1.800 / 1.500 / 1.380
1.800 / 1.500 / 1.380
6,0
42 / 37 / 35
42 / 37 / 35
60 / 55 / 53
60 / 55 / 53
235 x 1.590 x 690
40
2.040 / 1.680 / 1.440
2.040 / 1.680 / 1.440
7,9
46 / 40 / 36
46 / 40 / 36
64 / 58 / 54
64 / 58 / 54
235 x 1.590 x 690
40
2.100 / 1.740 / 1.500
2.100 / 1.740 / 1.500
9,0
47 / 41 / 37
47 / 41 / 37
65 / 59 / 55
65 / 59 / 55
235 x 1.590 x 690
40
220 / 230 / 240
16
2,5
6,55 / 6,25 / 6,00
6,70 / 6,40 / 6,15
1.800 / 2.100
46 / 50
65 / 69
569 x 790 x 285
42
1/4 (6,35)
1/2 (12,7)
1,65
30
5 / 40
30
20
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
7,15 / 6,90 / 6,70
8,10 / 7,80 / 7,60
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
68
3/8 (9,52)
5/8 (15,88)
2,00
30
5 / 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
20
2,5
9,00 / 8,70 / 8,40
8,90 / 8,60 / 8,30
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
69
3/8 (9,52)
5/8 (15,88)
2,35
30
5 / 50
30
50
-15 / +46
-20 / +24
220 / 230 / 240
25
4
11,5 / 11,1 / 10,6
11,8 / 11,4 / 11,0
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,40
30
5 / 75
30
50
-15 / +46
-20 / +24
220 / 230 / 240
30
6
17,0 / 16,4 / 15,8
16,0 / 15,4 / 14,9
7.800 / 6.600
53 / 53
70 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,40
30
5 / 75
30
50
-15 / +46
-20 / +24
220 / 230 / 240
16
2,5
21,2 / 20,5 / 19,8
19,8 / 19,2 / 18,5
8.100 / 7.200
54 / 55
71 / 71
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,40
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
3,00 / 2,90 / 2,80
3,00 / 2,90 / 2,80
3.600 / 3.600
48 / 50
65 / 67
996 x 940 x 340
71
3/8 (9,52)
5/8 (15,88)
2,35
30
5 / 50
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
3,95 / 3,75 / 3,65
4,05 / 3,85 / 3,75
6.600 / 5.700
52 / 52
69 / 69
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,40
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
5,85 / 5,55 / 5,35
5,50 / 5,20 / 5,05
7.800 / 6.600
53 / 53
70 / 70
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,40
30
5 / 75
30
50
-15 / +46
-20 / +24
380 / 400 / 415
16
2,5
7,30 / 6,95 / 6,70
6,85 / 6,50 / 6,25
8.100 / 7.200
54 / 55
71 / 71
1.416 x 940 x 340
98
3/8 (9,52)
5/8 (15,88)
3,40
30
5 / 75
30
50
-15 / +46
-20 / +24
indoor unit including defrost correction factor. 6) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1,5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97
specification. 7) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A.
For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
ELITE
Internet
Energy
6,80 A++
SEER
4,10 A+
SCOP
N
AL
saving
OP
TIO
Control
Ready
INTERNET CONTROL
SEASONAL ENERGY
EFFICIENCY RATIO
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-60PT2E5A.
SEASONAL COEFFICIENT
OF PERFORMANCE
Down to
Down to
-15°C in
-20°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
U-50PE1E5
U-60PE1E5A
U-71PE1E5A
U-71PE1E8A
U-100PE1E5A U-100PE1E8A
U-125PE1E5A U-125PE1E8A
U-140PE1E5A U-140PE1E8A
43
Panasonic breaks new ground in offering high performance and power in a small space. The 20-25 kW from
Panasonic is ideally suited for large retail applications and other large areas not needing the higher capacities
of VRF systems. The lightweight and compact design enables easier installation in any commercial space. The
twin fan system saves valuable footprint compared to traditional 20-25kW systems which are larger and
therefore require more space.
HIGH STATIC PRESSURE
HIDE AWAY 20-25kW
BIG PACi INVERTER+
Internet
Energy
TIO
N
AL
saving
OP
Control
Ready
INTERNET CONTROL
Down to
Down to
-15°C in
-20°C in
Easy
cooling mode
heating mode
control
by BMS
OUTDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
CONNECTIVITY
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
INTERNET CONTROL READY: Optional.
KIT
Indoor
Outdoor
Timer remote controller
Cooling capacity
Nominal (Min - Max)
Nominal
EER 1)
SEER 2)
Power input cooling
Nominal
Running amperes
Heating capacity
Nominal (Min - Max)
Nominal
Heating capacity at -7°C 3)
3)
Nominal
Heating capacity at -15°C
Nominal
COP 1)
4)
SCOP
Power input heating
Nominal
Running amperes
Indoor unit
Power source
External static pressure at shipment (with booster cable)
Air volume
Hi / Med / Lo
Moisture removal volume
Cooling
5)
Hi / Med / Lo
Sound pressure level
Sound power level
Hi / Med / Lo
Dimensions
HxWxD
Net weight
Outdoor unit
Power source
Recommended fuse
Air volume
Cooling / Heating
Cooling / Heating (Hi)
Sound pressure level 5)
Sound power level
Dimensions 6)
HxWxD
Net weight
Piping connections
Liquid pipe
Gas pipe
Refrigerant loading
7)
Max
Elevation difference (in/out)
Piping length
Min - Max
Precharge length
Max
Additional charge
Operating range
Cooling Min / Max
Heating Min / Max
kW
W/W
W/W
kW
A
kW
kW
kW
W/W
W/W
kW
A
Three Phase
20,0 kW
KIT-200PE2E5
S-200PE2E5
U-200PE1E8
CZ-RTC4
19,5 (6,0 - 22,4)
3,04 B
25,0 kW
KIT-250PE2E5
S-250PE2E5
U-250PE1E8
CZ-RTC4
25,0 (6,0 - 22,4)
3,04 B
6,42
—
22,4 (6,0 - 25,0)
17,34
16,00
3,54 B
6,42
—
28,0 (6,0 - 25,0)
21,85
20,16
3,54 B
6,32
—
6,32
—
V / ph / Hz
Pa
m³/h
l/h
dB(A)
dB
mm
kg
220 - 230 - 240 / 1 / 50
60
3.360 / 3.060 / 2.640
—
43 / 41 / 38
75 / 73 / 70
479 x 1.453 x 1.205
100
220 - 230 - 240 / 1 / 50
72
4.320 / 3.780 / 3.180
—
47 / 45 / 42
79 / 77 / 74
479 x 1.453 x 1.205
104
V / ph / Hz
A
m³/h
dB(A)
dB
mm
kg
mm (Inch)
mm (Inch)
kg
m
m
m
g/m
°C
°C
380 / 400 / 415 / 3+N / 50
15
7.740
57 / 57
72
1.526 x 940 x 340
118
9,52 (3/8)
25,4 (1)
5,3
30 / 30
5 - 100
30
40
-15 / +46
-20 / +24
380 / 400 / 415 / 3+N / 50
20
7.740
57 / 57
72
1.526 x 940 x 340
118
12,7 (1/2)
25,4 (1)
5,3
30 / 30
5 - 100
30
40
-15 / +46
-20 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
1) EER and COP, Energy Saving Classification, is at 220 / 240 V (380 / 415 V) only in accordance with EU directive 2002/31/EC. 2) SEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50,
EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0,2, b=0,36, c=0,32 and d=0,03. The internal
temperatures are taken at 27°C DB and 19°C WB. 3) Heating capacity is calculated including defrost factor correction. 4) SCOP is calculated in base Eurovent IPLV for SBEM with U1 indoor unit including defrost correction factor. 5) The sound pressure Level of the units
shows the value measured of a position 1 meter in front of the main body and 1,5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 6) Add 100 mm for indoor unit or 70 mm for outdoor unit for piping port. 7) When
installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu
44
NEW __ COMMERCIAL
HIGH
HEATING
CAPACIT Y
AT -7°C
Optional Controller
Wired remote controller
CZ-RTC5
NEW
Optional Controller
Timer remote controller
CZ-RTC4
Optional Controller
Wireless remote controller
CZ-RWSK2 + CZ-RWSC3
Optional Controller
Simplified remote controller
CZ-RE2C2
Compatible with all Panasonic connectivity solutions. For detailed information go to the Control Systems section.
Technical Focus
· High efficiency inverter system
· Cooling with low outdoor temperatures (down to -15°C)
· Maximum pipe length 100 m (more than 40% longer than other split systems)
· Multifunctional wireless remote control with built-in temperature control
· Fresh air supply for improved air quality
Features
ENERGY EFFICIENCY AND ECOLOGY
· Maximum efficiency Inverter system
· R410A environmentally friendly refrigerant gas
COMFORT
· Cooling with low outdoor temperatures (down to -15°C)
· Heating with low outdoor temperatures (down to -20°C)
· Selection of temperature sensor at indoor unit or wired remote control
EASY OF USE
· Weekly On/Off timer (6 settings per day and 42 per week)
· Selection of wired / Wireless and simplified wired remote controller
EASY INSTALLATION AND MAINTENANCE
· High static pressure units ideal for shops and offices
System example
An inspection port (450 x 450 mm or more) is required at the lower side of
the indoor unit body. Distributor (field supply).
Inspection port (450 x 450mm or more)
Plenums
Air Outlet Plenum (suitable for rigid + flexible duct)
N. of exits with diameters
S-250PE1E8
1 x 500 mm
S-200PE1E8A
1 x 450 mm
Model
CZ-TREMIESPW706
CZ-TREMIESPW705
U-200PE1E8
U-250PE1E8
45
PACi Twin, Triple and Double-Twin System
With this system, a single outdoor unit can split capacity for up to 4 indoor areas simultaneously. This makes the system
particularly apt for common areas. It reduces noise concentration and enables the same temperature to be reached around
the room. A mix of indoor units can be installed (wall, cassette, duct, ceiling) in one system.
PACi Standard Single and Twin System from 10,0 to 12,5 kW
Up to 2 indoor units connectable on the same outdoor. Panasonic’s PACi units can be installed as single and twin systems.
The indoor units can be combined following the selection table. The operation will always be simultaneous. All the indoor
units will work with the same settings.
PACi Elite Twin, Triple and Double-Twin System from 7,1 to 14,0 kW
Up to 4 indoor units can be connected to the same outdoor unit. Panasonic’s PACi units 71, 100, 125 and 140 can be installed
as twin, triple and double-twin systems. The indoor units can be combined as per the selection table. The operation will
always be simultaneous. All the indoor units will work with the same settings.
Big PACi Elite Twin, Triple and Double-Twin System from 20,0 to 25,0 kW
Up to 4 indoor units can be connected to the same outdoor unit. Panasonic’s PACi units 200 and 250 can be installed as twin,
triple and double-twin systems. The indoor units can be combined as per the selection table. The operation will always be
simultaneous. All the indoor units will work with the same settings.
46
NEW __ COMMERCIAL
Indoor unit capacities
Capacity Wall
4 Way 60x60 Cassette
4 Way 90x90 Cassette
Low Static Pressure Hide Away
High Static Pressure Hide Away
Celling
S-36PN1E5A
S-45PN1E5A
S-50PN1E5A
S-60PN1E5A
S-71PN1E5A
S-100PN1E5A
S-125PN1E5A
S-36PF1E5A
S-45PF1E5A
S-50PF1E5A
S-60PF1E5A
S-71PF1E5A
S-100PF1E5A
S-125PF1E5A
S-36PT2E5A
S-45PT2E5A
S-50PT2E5A
S-60PT2E5A
S-71PT2E5A
S-100PT2E5A
S-125PT2E5A
360º
air flow
3,6 kW
4,5 kW
5,0 kW
6,0 kW
7,1 kW
10,0 kW
12,5 kW
S-36PK1E5A
S-45PK1E5A
S-50PK1E5A
S-60PK1E5A
S-71PK1E5A
S-100PK1E5A
S-36PY2E5A
S-45PY2E5A
S-50PY2E5A
Outdoor unit capacities
Capacity
PACi Standard Single and Twin System
7,1 kW
10,0 kW
12,5 kW
14,0 kW
20,0 kW
25,0 kW
S-36PU1E5A
S-45PU1E5A
S-50PU1E5A
S-60PU1E5A
S-71PU1E5A
S-100PU1E5A
S-125PU1E5A
PACi Elite Twin, Triple and Double-Twin System from 7,1 to 14,0 kW
U-71PEY1E5
U-100PEY1E5 // U-100PEY1E8
U-125PEY1E5 // U-125PEY1E8
U-140PEY1E8
PACi Elite Twin, Triple and Double-Twin System from
20,0 to 25,0 kW
U-71PE1E5A // U-71PE1E8A
U-100PE1E5A // U-100PE1E8A
U-125PE1E5A // U-125PE1E8A
U-140PE1E5A // U-140PE1E8A
U-200PE1E8
U-250PE1E8
U-__1E5 Single Phase // U-__1E8 Three Phase
PACi Standard Single/Simultaneous operation system combinations
PACi Elite from 7,1 to 14,0 kW Single/Simultaneous operation system combinations
kW
Indoor
3,6
kW
Outdoor
Indoor 7,1
3,6
Twin
Outdoor
7,1
Twin U-71
10,0
12,5
14,0
10,0
Triple
12,5
Double-Twin
U-71
S-36
U-100
14,0
U-125
S-36
5,0
Twin
S-36
U-100
S-36
S-36
S-36
S-36
4,5
S-50
S-36
S-36
S-50
6,0
U-125
S-45
Single¹
S-60
5,0
Twin
U-71
S-71
Single¹
S-45
Triple
U-100
S-71
S-50
U-140
S-50
6,0
U-100
S-45
Twin
U-140
S-71
10,0
S-36
U-125
Twin
S-60
7,1
S-36
Triple
S-50
S-50
S-50
Twin
U-125
S-100
12,5
Single¹
S-60
U-125
7,1
S-125
S-60
Single¹
Twin
U-71
14,0
Single¹
U-140
U-140
S-71
S-140
10,0
S-71
S-71
Single¹
U-100
PACi Elite from 20,0 to 25,0 kW Single/Simultaneous operation system combinations
kW
Indoor
5,0
S-100
12,5
Outdoor
20,0
Double-Twin
25,0
Single¹
U-125
U-200
S-125
S-50
S-50
S-50
S-50
6,0
14,0
Double-Twin
S-60
7,1
Triple
10,0
Twin
U-250
S-60
S-71
S-71
S-100
S-60
S-140
1. PACi 1x1 Kit solution.
S-71
S-100
Twin
U-250
S-125
Single¹
U-140
U-200
12,5
20,0
S-60
U-200
Single¹
S-125
U-200
S-200
25,0
Single¹
U-250
S-250
1. PACi 1x1 Kit solution.
47
Single
Twin
Triple
CZ-280PAH1
CZ-280PAH1
CZ-280PAH1
L
L
L
A
H1
B
L1
L2
L1
H1
L3
H1
L2
H2
H4
H2
H3
PACi Standard Twin System
Joint distribution (sold separately)
A= CZ-P224BK2BM
Double-twin
CZ-280PAH1
L
A
L1
PACi Elite Twin, Triple and Double-Twin System
from 7,1 to 14,0 kW
Joint distribution (sold separately)
A= CZ-P224BK2BM
B= CZ-P3HPC2BM
C= CZ-P224BK2BM
L2
C
L3
L4
H1
H4
C
H7
L5
L6
H6
PACi Elite Twin, Triple and Double-Twin System
from 20,0 to 25,0 kW
Joint distribution (sold separately)
A = CZ-P680BK2BM
B = CZ-P3HPC2BM
C = CZ-P224BK2BM
H2
H3
H5
Twin System
PACi Standard Single and Twin System
PACi Elite Twin, Triple and Double-Twin System from 7,1 to 25 kW
Indoor unit
Equivalent lengths and Indoor unit combinations (see examples above)
combinations (see
height differences (m)
examples above)
for outdoor unit sizes...
Single
L
Twin
Triple
L + L1 + L2 L + L1 + L2 + L3
Maximum pipe length from outdoor –
unit to most distant indoor unit
Maximum branch pipe length
–
–
–
–
L1 L2
≤ 15
–
L + L1 or
L + L2
L1 or L2
Maximum branch pipe length
differences
–
L1 > L2
L1 - L2
≤ 10
–
L1 > L2:
L1 - L2
Maximum pipe length differences
after first branch (Double-Twin)
Maximum pipe length differences
after second branch (Double-Twin)
Height difference
(outdoor unit located higher)
Height difference
(outdoor unit located lower)
Height difference between indoor
units
–
–
–
–
–
–
L2 > L1: L2 - L1
≤ 10 m
≤ 10 m
–
–
–
–
–
–
≤ 10 m
≤ 10 m
H1
H1
≤ 30
H1
H1
H1
L4 > L3: L4 - L3
L6 > L5: L6 - L5
H1
≤ 30 m
≤ 30 m
H1
H1
≤ 15
H1
H1
H1
H1
≤ 15 m
≤ 15 m
–
H2
≤ 0.5
–
H2
H2 or H3 or H4
H2 or H3 or H4 or H5 or H6
≤ 0.5 m
≤ 0.5 m
Twin System
PACi Standard Single and Twin System
PACi Elite Twin, Triple and Double-Twin System from 7,1 to 14,0 kW
Outdoor unit main pipe Indoor unit connection Outdoor Indoor unit connection pipe diameter (L1, L2, L3, L4) (mm)
diameter (L)
tube (L1, L2)
unit main
pipe
diameter
(L)
PACi Elite Twin, Triple and Double-Twin System from 20,0 to 25,0 kW
Outdoor unit main pipe DoubleIndoor unit connection
diameter (L) (mm)
Twin
pipe diameter
distribution
pipe (L1,
L2)¹
Unit type capacity
Liquid pipe (mm)
Gas pipe (mm)
Additional charge (g/m)
100
Ø 9,52
Ø 15,88
50
200
Ø 9,52
Ø 25,4
40
125
Ø 12,7
Ø 15,88
50
50
Ø 6,35
Ø 12,7
20
60
Ø 9,52
Ø 15,88
50
71 - 140
Ø 9,52
Ø 15,88
50
36
Ø 6,35
Ø 12,70
20
Double-Twin
L + L1 + L2 + L3 + L4 + L5 + L6 U-60/U-71: ≤ 50 m
U-100/125/140: ≤ 75 m
L + L1 or L + L2 or L + L3 L + L1 + L3 or L + L1 + L4 or L –
+ L2 + L5 or L + L2 + L6
L1 or L2 or L3
L1 + L3 or L1 + L4 or L2 + L5 or ≤ 15 m
L2 + L6
L1 > L2 > L3: L1 - L2
L2 + L6 (Max.)
≤ 10 m
L2 - L3
L1 + L3 (Min.):
L1 - L3
(L2 + L6) - (L1 + L3)
Equivalent lengths and
height differences (m) for
outdoor unit sizes from
20,0 to 25,0 kW
Twin
L + L1 + L2 ≤ 50 m
Total pipe length
Single
L
Equivalent lengths and
height differences (m) for
outdoor unit sizes from 7,1
to 14,0 kW
45
Ø 6,35
Ø 12,70
20
50
Ø 6,35
Ø 12,70
20
60
Ø 9,52
Ø 15,88
50
71
Ø 9,52
Ø 15,88
50
250
Ø 12,7
Ø 25,4
80
100 - 125
Ø 9,52
Ø 15,88
40
≤ 100 m
≤ 100 m
≤ 20 m
≤ 10 m
50
Ø 6,35
Ø 12,7
20
60 - 125
Ø 9,52
Ø 15,88
40
1. Total capacity of indoor unit connected after the branch
Refrigerant charging: For the twin connection, the amount of refrigerant required for pipe length 30 m has been included in this unit at the factory while that required for pipe length 20 m has been included for the Triple / Double-Twin connections.
No additional charge is required for the first 30 m pipe length in the case of the twin connection and for the first 20 m in the case of the Triple / Double-Twin connections. The amount of included refrigerant for each model is listed on NAMA PLATE.
Make additional charges by adding up pipe length in an order of main (L branch pipe), (L1, L2, L3 wide diameter) and then selecting the amount of refrigerant corresponding to the remaining (after 30 m for the Twin connection and after 20 m for the Triple / Double-Twin
connections) liquid side pipe diameter and pipe length from the below table.
48
NEW __ COMMERCIAL
Optional Controller
Wired remote controller
CZ-RTC5
Optional Controller
Timer remote controller
CZ-RTC4
Optional Controller
Wireless remote controller
Various type.
Optional Controller
Simplified remote controller
CZ-RE2C2
Compatible with all Panasonic connectivity solutions. For detailed information go to the Control Systems section.
Compatible Indoor Units
Capacity for all indoor
Cooling
units
Heating
kW
kW
3,6 kW
3,6
4,2
4,5 kW
4,5
5,2
5,0 kW
5,0
5,6
6,0 kW
6,0
7,0
7,1 kW
7,1
8,0
10,0 kW
10,0
11,2
mm
dB(A)
dB(A)
m³ / h
m³ / h
S-36PK1E5A
300 x 1.065 x 230
35 / 31 / 27
35 / 31 / 27
660 / 570 / 450
660 / 570 / 450
S-45PK1E5A
300 x 1.065 x 230
38 / 34 / 30
38 / 34 / 30
720 / 630 / 510
720 / 630 / 510
S-50PK1E5A
300 x 1.065 x 230
40 / 36 / 32
40 / 36 / 32
840 / 720 / 630
840 / 720 / 630
S-60PK1E5A
300 x 1.065 x 230
47 / 44 / 40
47 / 44 / 40
1.080 / 870 / 690
1.080 / 870 / 690
S-71PK1E5A
300 x 1.065 x 230
47 / 44 / 40
47 / 44 / 40
1.080 / 870 / 690
1.080 / 870 / 690
S-100PK1E5A
300 x 1.065 x 230
47 / 44 / 40
47 / 44 / 40
1.140 / 990 / 780
1.140 / 990 / 780
mm
mm
mm
dB(A)
dB(A)
m³ / h
S-36PY2E5A
CZ-KPY3A / CZ-KPY3B
288 x 583 x 583
31 x 700 x 700
31 x 625 x 625
36 / 32 / 26
36 / 32 / 26
582 / 594
S-45PY2E5A
CZ-KPY3A / CZ-KPY3B
288 x 583 x 583
31 x 700 x 700
31 x 625 x 625
38 / 34 / 28
38 / 34 / 28
600 / 618
S-50PY2E5A
CZ-KPY3A / CZ-KPY3B
288 x 583 x 583
31 x 700 x 700
31 x 625 x 625
40 / 37 / 33
40 / 37 / 33
666 / 666
Indoor H x W x D
Panel H x W x D
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
mm
mm
dB(A)
dB(A)
m³ / h
m³ / h
S-36PU1E5A
CZ-KPU21
256 x 840 x 840
33,5 x 950 x 950
30 / 28 / 27
30 / 28 / 27
840 / 780 / 720
840 / 780 / 720
S-45PU1E5A
CZ-KPU21
256 x 840 x 840
33,5 x 950 x 950
31 / 28 / 27
31 / 28 / 27
900 / 780 / 720
900 / 780 / 720
S-50PU1E5A
CZ-KPU21
256 x 840 x 840
33,5 x 950 x 950
32 / 29 / 27
32 / 29 / 27
960 / 810 / 720
960 / 810 / 720
S-60PU1E5A
CZ-KPU21
256 x 840 x 840
33,5 x 950 x 950
36 / 31 / 28
36 / 31 / 28
1.260 / 1.020 / 840
1.260 / 1.020 / 840
S-71PU1E5A
CZ-KPU21
256 x 840 x 840
33,5 x 950 x 950
37 / 31 / 28
37 / 31 / 28
1.320 / 1.020 / 840
1.320 / 1.020 / 840
S-100PU1E5A
CZ-KPU21
319 x 840 x 840
33,5 x 950 x 950
44 / 38 / 32
44 / 38 / 32
1.980 / 1.620 / 1.260
1.980 / 1.620 / 1.260
S-125PU1E5A
CZ-KPU21
319 x 840 x 840
33,5 x 950 x 950
45 / 39 / 33
45 / 39 / 33
2.100 / 1.680 / 1.320
2.100 / 1.680 / 1.320
Low Static Pressure Hide Away
Dimensions
HxWxD
Sound pressure level
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
External static pressure High / Medium / Low
Air volume
Cooling / Heating
mm
dB(A)
dB(A)
Pa
m³ / h
S-36PN1E5A
250 x 780(+100) x 650
40 / 38 / 35
40 / 38 / 35
80 / 50 / 10
840 / 840
S-45PN1E5A
250 x 780(+100) x 650
41 / 39 / 35
41 / 39 / 35
80 / 50 / 10
960 / 960
S-50PN1E5A
250 x 780(+100) x 650
41 / 39 / 35
41 / 39 / 35
80 / 50 / 10
960 / 960
S-60PN1E5A
250 x 1.000(+100) x 650
43 / 41 / 36
43 / 41 / 36
80 / 50 / 10
1.320 / 1.320
S-71PN1E5A
250 x 1.000(+100) x 650
43 / 41 / 36
43 / 41 / 36
80 / 50 / 10
1.320 / 1.320
S-100PN1E5A
250 x 1.200(+100) x 650
44 / 42 / 37
44 / 42 / 37
80 / 50 / 10
2.160 / 2.160
S-125PN1E5A
250 x 1.200(+100) x 650
46 / 44 / 39
46 / 44 / 39
80 / 50 / 10
2.280 / 2.280
Hide Away High Static Pressure
Dimensions
HxWxD
Sound pressure level
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
External static pressure High / Medium / Low
Air volume
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
mm
dB(A)
dB(A)
Pa
m³ / h
m³ / h
S-36PF1E5A
290 x 800 x 700
33 / 29 / 25
33 / 29 / 25
150 / 70 / 10
840 / 780 / 600
840 / 780 / 600
S-45PF1E5A
290 x 800 x 700
34 / 30 / 26
34 / 30 / 26
150 / 70 / 10
840 / 780 / 600
840 / 780 / 600
S-50PF1E5A
290 x 800 x 700
34 / 30 / 26
34 / 30 / 26
150 / 70 / 10
960 / 900 / 720
960 / 900 / 720
S-60PF1E5A
290 x 1.000 x 700
35 / 32 / 26
35 / 32 / 26
150 / 70 / 10
1.260 / 1.140 / 900
1.260 / 1.140 / 900
S-71PF1E5A
290 x 1.000 x 700
35 / 32 / 26
35 / 32 / 26
150 / 70 / 10
1.260 / 1.140 / 900
1.260 / 1.140 / 900
S-100PF1E5A
290 x 1.400 x 700
38 / 34 / 31
38 / 34 / 31
150 / 100 / 10
1.920 / 1.560 / 1.260
1.920 / 1.560 / 1.260
S-125PF1E5A
290 x 1.400 x 700
39 / 35 / 32
39 / 35 / 32
150 / 100 / 10
2.040 / 1.740 / 1.380
2.040 / 1.740 / 1.380
mm
dB(A)
dB(A)
m³ / h
m³ / h
S-36PT2E5A
235 x 960 x 690
35 / 32 / 30
36 / 32 / 30
840 / 720 / 630
840 / 720 / 630
S-45PT2E5A
235 x 960 x 690
38 / 33 / 30
39 / 34 / 30
900 / 750 / 630
900 / 750 / 630
S-50PT2E5A
235 x 960 x 690
38 / 33 / 30
39 / 34 / 30
900 / 750 / 630
900 / 750 / 630
S-60PT2E5A
235 x 1.275 x 690
39 / 36 / 33
40 / 36 / 33
1.200 / 1.020 / 870
1.200 / 1.020 / 870
S-71PT2E5A
235 x 1.275 x 690
39 / 36 / 33
40 / 36 / 33
1.260 / 1.080 / 930
1.260 / 1.080 / 930
S-100PT2E5A
235 x 1.590 x 690
42 / 38 / 35
42 / 38 / 35
1.800 / 1.500 / 1.380
1.800 / 1.500 / 1.380
S-125PT2E5A
235 x 1.590 x 690
45 / 40 / 37
46 / 41 / 38
2.040 / 1.680 / 1.440
2.040 / 1.680 / 1.440
Wall
Dimensions
Sound pressure level
Air volume
4 Way 60x60 Cassette
Panel
Dimensions (H x W x D)
Sound pressure level
Air volume
4 Way 90x90 Cassette
Panel
Dimensions
Sound pressure level
Air volume
Ceiling
Dimensions
Sound pressure level
Air volume
HxWxD
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
Indoor
Panel CZ-KPY3A
Panel CZ-KPY3B
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
Cooling / Heating
HxWxD
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
Cooling (Hi / Me / Lo)
Heating (Hi / Me / Lo)
Compatible Outdoor Units
Outdoor Single Phase
Outdoor Three Phase
Cooling capacity
Nominal (Min - Max)
Heating capacity
Nominal (Min - Max)
Power source
Single Phase
Three Phase
Connection
Air volume
Cooling / Heating
Sound pressure level
Cooling / Heating (Hi)
Sound power level
Cooling / Heating (Hi)
Dimensions
HxWxD
Net weight
Piping connections
Liquid pipe
Gas pipe
Refrigerant Loading
R410A
Elevation difference (in/out) Max
Piping length
Min / Max
Operating range
Cooling Min / Max
Heating Min / Max
7,1 kW
U-71PEY1E5
—
kW
7,1 (2,0 - 7,7)
kW
7,1 (1,8 - 8,1)
V
220 / 230 / 240
V
—
mm²
2,50
m³/h
2.340
dB(A)
50 / 52
dB
70 / 70
mm
569x790x285
kg
42
Inch (mm) 3/8 (9,52)
Inch (mm) 5/8 (15,88)
kg
1,7
m
30
m
5 / 50
°C
-10 / +43
°C
-15 / +24
10,0 kW
U-100PEY1E5
U-100PEY1E8
10,0 (2,7 - 11,5)
10,0 (2,1 - 13,8)
220 / 230 / 240
380 / 400 / 415
4,00
4.560 / 4.020
54 / 54
70 / 70
996x940x340
73
3/8 (9,52)
5/8 (15,88)
2,60
30
5 / 50
-10 / +43
-15 / +24
12,5 kW
U-125PEY1E5
U-125PEY1E8
12,5 (3,8 - 13,5)
12,5 (3,4 - 15,0)
220 / 230 / 240
380 / 400 / 415
6,00
4.800 / 4.380
56 / 56
73 / 73
996x940x340
85
3/8 (9,52)
5/8 (15,88)
3,20
30
5 / 50
-10 / +43
-15 / +24
14,0 kW
—
U-140PEY1E8
14,0 (3,3 - 15,5)
14,0 (4,1 - 16,0)
—
380 / 415
2,50
8.100 / 7.200
54 / 53
71 / 70
1.416x940x340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 50
-10 / +43
-15 / +24
7,1 kW
U-71PE1E5A
U-71PE1E8A
7,1 (2,5 - 8,0)
8,0 (2,0 - 9,0)
220 / 240
380 / 415
2 x 1,5 or 2,5
3.600 / 3.600
48 / 50
65 / 67
996x940x340
69
3/8 (9,52)
5/8 (15,88)
2,35
30
5 / 50
-15 / +46
-20 / +24
10,0 kW
U-100PE1E5A
U-100PE1E8A
10,0 (3,3 - 12,5)
11,2 (4,1 - 14,0)
220 / 240
380 / 415
2 x 1,5 or 2,5
6.600 / 5.700
52 / 52
69 / 69
1.416x940x340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
-15 / +46
-20 / +24
12,5 kW
U-125PE1E5A
U-125PE1E8A
12,5 (3,3 - 14,0)
14,0 (4,1 - 16,0)
220 / 240
380 / 415
2 x 1,5 or 2,5
7.800 / 6.600
53 / 53
70 / 70
1.416x940x340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
-15 / +46
-20 / +24
14,0 kW
U-140PE1E5A
U-140PE1E8A
14,0 (3,3 - 15,5)
16,0 (4,1 - 18,0)
220 / 240
380 / 415
2 x 1,5 or 2,5
8.100 / 7.200
54 / 55
71 / 71
1.416x940x340
98
3/8 (9,52)
5/8 (15,88)
3,4
30
5 / 75
-15 / +46
-20 / +24
12,5 kW
12,5
14,0
20,0 kW
25,0 kW
U-200PE1E8 U-250PE1E8
20,0 (6,0 - 22,4) 25,0 (6,0 - 28,0)
21,8 (6,0 - 22,4) 28,0 (6,0 - 31,5)
380 / 415
—
7740
57 / 57
72
1526x940x340
118
9,52 (3/8)
25,4 (1)
5,3
30
5 / 100
-15 / +43
-20 / +15
380 / 415
—
7080
57 / 58
73
1526x940x340
128
12,7 (1/2)
25,4 (1)
6,5
30
5 / 100
-15 / +43
-20 / +15
49
Air curtains can help reduce whole building heating or cooling costs by helping to stop heat escaping the
building or keeping cooled air in. Panasonic offers two sizes - 900mm and 1200mm electric air curtains. Ideal
for separating areas and energy saving.
ELECTRIC AIR CURTAIN
Width
Watts
Current
Air speed
Air volume
Noise lever
Hi
Lo
Hi
Lo
Hi
Lo
Hi
Lo
Hi
Lo
W
W
A
A
m/s
m/s
m³/h
m³/h
dB(A)
dB(A)
kg
Weight
FY-10ESPNAH
900
71,5
61,5
0,40
0,29
13,0
11,1
750
630
46
42
11
FY-10ELPNAH
1.200
96
74
0,54
0,35
13,1
11,0
1.000
830
46
41
14
Indoor unit dimensions FY-10ESPNAH
FRONT VIEW
BACK VIEW
Absorption inlet
50
400
400
205
50
120
226
63
900
5 fixing points
8mm holes
Air outlet
Indoor unit dimensions FY-10ELPNAH
FRONT VIEW
Absorption inlet
200
400
400
205
200
120
226
63
1.200
BACK VIEW
5 fixing points
8mm holes
50
Air outlet
NEW __ COMMERCIAL
Technical Focus
· 2 sizes: 900 mm and 1.200 mm
· Powerful air flow (10 m/s)
· Very low noise, only 42 dB
Features
COMFORT
· Easy redirection of airflow by means of the manual deflector
EASE OF USE
· Speed selector (high and low) on the unit itself
EASY INSTALLATION AND MAINTENANCE
· Simple installation
· Compact dimensions improve installation and positioning in any space
3m
1m
5.5 - 6.0 m/s
2m
3.5 - 4.5 m/s
3m
3.0 - 3.5 m/s
4m
2.0 - 3.0 m/s
Effectiveness of air
51
Air Curtain with DX Coil
Connected to the PACi or VRF Systems
The Panasonic range of air curtains is designed for smooth operation
and efficient performance. Air curtains produce a continuous stream of
air blown from the top to the bottom of an open doorway and create a
barrier that people and products can flow across, but air can’t. Designed
to improve energy efficiency, minimise heat loss from a building, and to
allow retailers to keep doors open to encourage customers, our Air
Curtains are suitable for connection to both PACi and VRF Systems.
Heating capacity comparison:
Electrical Air curtain / Panasonic Air Curtain
100
80
80%*
60
more efficient
40
Electric air
curtain
20
PANASONIC
AIR CURTAIN
0
* With the U-100PE1E5 on the PAW-20PAIRC-MS.
Calculation method: Taking as consideration SCOP of the Panasonic combination of 6,0. If 100 is
the energy needed for a air curtain, Panasonic Air curtain will need 1/(1-6)*100=20.
52
· Super-efficient with new EC fan motor (40% lower running costs compared to a
standard AC fan motor)
· Easy Cleaning and Servicing
· Can be connected to either Panasonic PACi or VRF systems
· Built-in drain for cooling operation
· Standard and Jet Flow air curtains can be controlled via Panasonic’s range of remote
internet controls
The new standard and jet-flow models are ideal for connection to a PACi or ECOi system.
With simple ‘plug and play’ installation, both are fitted with an EC fan motor for a
smooth operation and efficient performance. This new fan guarantees 40% lower running
cost than with a standard AC fan motor. With air curtains often running for 12 hours a
day as a minimum, this can lead to considerable savings.
Highly efficient heating effect
The combined air stream, which has a desirable low air current induction factor (mixing
factor), can carry the selected initial temperature effect over long distances, and will
reach the floor area while still at room temperature. This is necessary to avoid cooling
down the interior spaces.
Available in different lengths to suit requirements between 1 and 2,5m, both air curtains
have outlet grilles that can be adjusted to five different positions. The jet flow model
can be installed up to a height of 3,5m with the standard model up to 3,0m. The outlet
grilles can be easily adjusted into five positions to suit different installations
requirements and the air filter can be accessed without the need for specialist tools.
NEW __ COMMERCIAL
Intelligent Operation
Our air curtains combine air flow and heating /
cooling technology to ensure optimum comfort and
energy efficiency whilst also creating an effective
barrier between indoor and outdoor environments.
Design and installation is key to achieving the
correct height / temperature settings to achieve
optimum performance. Our air curtains are designed
to answer the demands of the retail, commercial and
industrial markets.
Height / Temperature
100 mm
Supply air exit
0,0 m / 34°C
Air curtain
Open air
Inside air
Internet Control
An app added to your tablet or smartphone or via the Internet allows you to control and manage the system
remotely. There is also the option to integrate into existing BMS systems by using other Panasonic interfaces.
Optimised air flow velocity
1. Energy losses, no air curtain installed
2. Too low velocity air curtain – Air Curtain not efficient
3. Optimum results with the Tekadoor Air Curtain connected to Panasonic PACi
4. Too high velocity air curtain – considerable turbulence, energy lost to the outside, Air Curtain not efficient
0,5 m / 30°C
4
5.0 m/s
1,0 m / 26°C
1,5 m / 23°C
Induction
open air
Induction
inside air
2.0 m/s
Ideal air flow:
1.5-2 m/s at 15cm from the floor
3
2,0 m / 21°C
For a optimum efficiency, Air flow
velocity at 15cm from the floor
should be 1,5 to 2.0 m/s
2,5 m / 20°C
2
0.5 m/s
Floor
How does it work?
Stale air from the room is taken in and ejected near
the door. This creates a ‘roll of air’ that shields the
door area, mixing with the colder incoming air. It then
turns away from the door, back into the room and
toward the intake screen, where it is partly drawn in
again. This flow of air helps to create a barrier for
heat loss yet at the same time refreshes room air.
1
0 m/s
53
AIR CURTAIN WITH DX COIL
High efficiency Air curtain connected to your PACi installation on 1x1 connection!
Plug & Play Installation
EC Fan motor for a smooth operation and efficient performance.
2 types of Air flow available: Jet-Flow and Standard.
2015 Fan Standard available today.
Easy Cleaning and Servicing.
Max installation high
Jet-Flow: 3,5 m
Standard flow: 3,0 m
Easy
control
by BMS
CONNECTIVITY
HP
Air Curtain
Air flow type
Air Flow Length (A)
Air volume
High
Medium
Low
Cooling capacity nominal¹
Heating capacity with air in 20°C, air out 40°C
Heating capacity with air in 20°C, air out 35°C
Heating capacity with air in 20°C, air out 30°C
Max installation height Good condition
Normal condition
Bad condition
Refrigerant
Liquid pipe
Gas pipe
Fan
Fan type
Currency
High
Med
Low
Electrical Consumption High
Med
Low
Protecting Fuse
Noise
Dimensions
WxHxD
Weight
Outdoor combination with PACi Elite unit 40°C
Outdoor combination with PACi Standard unit 40°C
Outdoor combination with PACi Elite unit 35°C
Outdoor combination with PACi Standard unit 35°C
Outdoor combination with PACi Elite unit 30°C
Outdoor combination with PACi Standard unit 30°C
m
m²/h
m²/h
m²/h
kW
kW
kW
kW
m
m
m
Inch (mm)
Inch (mm)
A
A
A
kW
kW
kW
A
dB(A)
mm
kg
4 HP
PAW-10PAIRC-MJ
Jet-flow
1,0
1.800
1.500
1.200
9,2
11,9
8,9
5,9
3,5
3,1
2,7
R410A
3/8 (9,52)
5/8 (15,88)
230V / 50Hz / 1 / N / PE
EC
2,1
0,8
0,3
0,44
0,17
0,06
M16A
40-55
1.210 x 260 x 590
70
6 HP
PAW-15PAIRC-MJ
8 HP
PAW-20PAIRC-MJ
2,0
3.600
3.000
2.500
23,1
23,9
17,9
11,9
3,5
3,1
2,7
R410A
3/8 (9,52)
7/8 (22,22)
230V / 50Hz / 1 / N / PE
EC
4,2
1,6
0,6
0,89
0,34
0,12
M16A
40-57
2.210 x 260 x 590
138
4 HP
PAW-10PAIRC-MS
Standard
1,0
1.800
1.500
1.200
9,2
11,9
8,9
5,9
3,0
2,7
2,4
R410A
3/8 (9,52)
5/8 (15,88)
230V / 50Hz / 1 / N / PE
EC
2,1
0,8
0,3
0,44
0,17
0,06
M16A
40-55
1.210 x 260 x 490
60
1,5
2.700
2.300
1.900
17,5
17,9
13,4
8,9
3,5
3,1
2,7
R410A
3/8 (9,52)
3/4 (19,05)
230V / 50Hz / 1 / N / PE
EC
2,8
1,1
0,4
0,59
0,23
0,08
M16A
40-56
1.710 x 260 x 590
100
U-100PE1E5/8
U-100PEY1E5/8
U-71PE1E5/8
U-100PEY1E5/8
U-50PE1E5
U-60PEY1E5
U-140PE1E5/8
—
U-100PE1E5/8
U-100PEY1E5/8
U-100PE1E5/8
U-100PEY1E5/8
2,0
2.700
2.300
1.900
17,5
17,9
13,4
8,9
3,0
2,7
2,4
R410A
3/8 (9,52)
7/8 (22,22)
230V / 50Hz / 1 / N / PE
EC
4,2
1,6
0,6
0,89
0,34
0,12
M16A
40-57
2.210 x 260 x 490
128
U-200PE1E8
—
U-140PE1E5/8
—
U-100PE1E5/8
U-100PEY1E5/8
U-100PE1E5/8
U-100PEY1E5/8
U-71PE1E5/8
U-100PEY1E5/8
U-50PE1E5
U-60PEY1E5
U-140PE1E5/8
—
U-100PE1E5/8
U-100PEY1E5/8
U-100PE1E5/8
U-100PEY1E5/8
All combinations under rated conditions: Heating Outdoor +7°C DB/+6°C WB Indoor +20°C DB. In case of lower outdoor temperatures a higher capacity outdoor unit model may be necessary
1) Rated Conditions Cooling Outdoor +35°C DB Indoor +27°C DB/+19°C WB, Discharge temperature ³ 16°C.
54
.
8 HP
PAW-20PAIRC-MS
NEW __ COMMERCIAL
Technical focus
Features
· Save up to 40% Energy Costs by use of the integrated EC Fan Technology (Higher
efficiency than conventional AC fan, softstart and longer motor duration)
· 3 Lengths of Air Curtains Jet-Flow, from 1 to 2 m and 2 lengths of Air Curtains
Standard, 1 and 2 m
· Installation Height up to 3,5 m (Jet-Flow) and 3,0 m (Standard)
· Outlet Grilles can be adjusted in five positions, to suite different Indoor and
installation requirements (Jet-Flow)
· Control with Panasonic Remote Control systems (optional)
· Direct integration to BMS by optional Panasonic Interfaces
· Drain included for cooling operation
· Drain pump and float switch available for forced drainage
Jet-flow dimensions
COMFORT
· Easy redirection of Air-Flow by means of manual deflector (Jet-Flow)
EASE OF USE
· Speed selectable on remote controller with 3 speeds
EASY INSTALLATION AND MAINTENANCE
· Easy installation
· Compact dimensions improve installation and positinioning (Jet-Flow)
· Easy cleaning of grid without opening of the unit
· Continuos operation even in case of 1 fan motor failure without stopping air curtain
function or stopping the complete system
· Warning indication on remote controller display
Standard dimensions
TOP VIEW
TOP VIEW
A
A
45
SIDE VIEW
Rivetting nut M8
85
295 560
Pressure line
Intake line
75 45
75 45
45
SIDE VIEW
Rivetting nut M8
35 295
460
Pressure line
Intake line
60
100
60
100
FRONT VIEW
FRONT VIEW
A+210
A+210
105
105
SECTION
105
105
100 30
SECTION
260
30
BOTTOM VIEW
100 30
260
30
BOTTOM VIEW
70
120
25
A
PAW-10PAIRC-MJ PAW-15PAIRC-MJ PAW-20PAIRC-MJ PAW-25EAIRC-MJ
1,000
1,500
2,000
2,500
A
PAW-10PAIRC-MS PAW-20PAIRC-MS
1,000
2,000
55
Air Handling Unit Kit 10-25 kW for PACi
New AHU Kit connects PACi outdoor units to Air Handling Units system
The Panasonic AHU Kits offer a wealth of connectivity possibilities so can be easily integrated into many systems.
Application: Hotels, offices, server rooms or all large buildings where air quality control such as humidity control
and fresh air and is needed.
2 types of AHU Kit: Advanced and Standard
Model Code
CZ-280PAH1
PAW-280PAH2
PAW-280PAH2L
1
5
IP 65
0-10V demand control
Outdoor temperature shift compensation. Cold draft prevention
Yes
Yes
Yes
No
Yes
No
1. Remote control CZ-RTC4
2. New plastic IP 65 Box
3. PAW-T10 PCB for dry contact
4. 0-10V demand control PCB
5. Intelligent thermostat for:
· Cold draft prevention
· Outdoor temperature shift compensation
6. Terminal base for sensors and power supply
AHU Connection Kit
PCB, Power trans,
Terminal block
Thermistor x2
(Refrigerant: E1, E3)
Thermistor
(Air: TA; 1 sensor)
2
6
3
Remote controller
4
Standard wired remote controller.
Can be installed inside the box.
56
NEW __ COMMERCIAL
Panasonic AHU Kit, 10-25 kW connected to PACi outdoor unit
0-10V control
The new Air Handling Unit Kit has been developed to better meet customer demand:
· IP 65 Box in order to be installed outside
· 0-10V demand control*
· Easy control by BMS
With the 0-10 v demand control the capacity
of the outdoor unit can be controlled by 20
steps
Analog input (V)
0 (not connect)
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
6,5
7,0
7,5
8,0
8,5
9,0
9,5
10,0
* Only available with Elite PACi, up to from 6kW to 14kW.
Controller wiring
CZ-RTC4
Air Handling Unit Kit
PAW-280PAH2
I/D-O/D
wiring
Wiring for Thermostat
& Solenoid Valve
Piping
PACi
Demand (%)
Free
Stop
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
Free
0 (TH. OFF)
Air Handling Unit
Optional parts: Following functions are available by using different control accessories
PAW-T10, PCB to connect to T10 connector
· A Dry contact PCB has been developed to easily control the unit
· Input signal operation ON/OFF
· Remote control prohibition
· Output signal operation ON status maximum 230 V 5 A (NO/NC)
· Output signal alarm status maximum 230 V 5 A (NO/NC)
· Additional available contacts:
- External humidifier control (ON/OFF) 230 VAC 3 A
- External fan control (ON/OFF) 12V DC
- External filter status signal potential free
- External float switch signal potential free
- External leakage detection sensor or TH. OFF contact potential free
(possible usage for external blow out temperature control)
CZ-RTC4 Timer remote controller
· Operation-ON/OFF
· Mode select
· Temperature setting
* Fan operation signal can be taken from the PCB.
CZ-T10 terminal
· Input signal= Operation ON/OFF
· Remote controller prohibition
· Output signal= Operating-ON status
· Alarm output (by DC12 V)
PAW-OCT, DC12 V outlet. OPTION terminal
· Output signal= Cooling / Heating/Fan status
· Defrost
· Thermostat-ON
Combination table for PACi single outdoor unit
Combination shown in below table is available for PACi single system
Power
Size
Single Phase
5,0 kW
6,0 kW
7,1 kW
10,0 kW
12,5 kW
14,0 kW
Three Phase
10,0 kW
12,5 kW
14,0 kW
20,0 kW
25,0 kW
PACi Standard
U-50PEY1E5
U-60PEY1E5
U-71PEY1E5
PACi Elite
U-100PE1E5A
U-125PE1E5A
U-140PE1E5A
U-100PE1E8A
U-125PE1E8A
U-140PE1E8A
U-200PE1E8
U-250PE1E8
AHU kit
CZ-280PAH1 // PAW-280PAH2 // PAW-280PAH2L
(Common use for all outdoor units. Only 1 by 1
connection is allowed.)
* Additional notice/instruction for system design, installation work will be defined for PACi connection.
57
Possible
to use on
R22 pipings
R22 RENEWAL
R22 Renewal
Why renewal?
Unique R22 Renewal from Panasonic: Fast, easy to install and
Cost effective
· Panasonic refrigerant oil doesn’t react to the most common oil types
used in air-conditioning systems. This ensures the mix of oil does not
damage the units. Therefore installations are easier.
· All Panasonic PACi units can be installed in R22 pipings, no specific
models are available.
· Up to 33 Bar! When there is any doubt about the strength of the
piping, the maximum working pressure can be reduced to 33 Bar with
a setting in the software of the outdoor unit.
An important drive to further reduce the potential damage to our ozone
It is often said that legislation is ruling our lives but sometimes it is there to
help save lives. R22 phase out can be described as one of these and from Jan
1st 2010 the use of Virgin (new) R22 refrigerant was banned within the
European Community.
Panasonic are doing our part
We at Panasonic are also doing our part – recognising that all finances are
under pressure at the moment. Panasonic has developed a clean and cost
effective solution to enable this latest legislation to be introduced with as
minimum an effect on businesses and cash reserves as possible.
The Panasonic renewal system allows good quality existing R22 pipe work to
be re-used whilst installing new high efficiency R410A systems.
By bringing a simple solution to the problem Panasonic can renew all Split
Systems and PACi systems; and depending upon certain restrictions we don’t
even limit the manufacturer’s equipment we are replacing.
By installing a new high efficiency Panasonic R410A system you can benefit
from around 30% running cost saving compared to the R22 system.
Yes...
1. Check the capacity of the system you wish to replace
2. Select from the Panasonic range the best system to replace it with
3. Follow the procedure detailed in the brochure and technical data
Simple...
R22 - The reduction of Chlorine critical for a cleaner future
58
Reuse of existing piping (Renewal Design & Installation)
Notes on reuse of existing refrigerant piping
It is possible for each series of PE1 type and PEY1 type outdoor unit to
reuse the existing refrigerant piping without cleaning when obtained under
certain conditions.. Make sure that the requirements under the section
“Notes on reuse of existing refrigerant piping”, “Measurement procedure
for renewal” and “Refrigerant piping size and allowable piping length” will
be satisfied in order to carry out .
Also, check the items with regard to section “Safety” and “Cleaning”.
1. Prerequisite
· If the refrigerant used for the existing unit is other than R22, R407C and R410A, the
existing refrigerant piping cannot be used.
· If the existing unit has another use than air conditioning, then existing refrigerant piping
cannot be used.
2. Safety
· If there is a hollow, crack or corrosion on the piping, make sure to install new piping.
· If the existing piping is other than capable of reuse of piping as shown in the flowchart,
make sure to install new piping.
· In case of multiple operation type, use our genuine branch piping for refrigerant R410A.
A local supplier shall assume responsibility for the defects and hollows on the reuse of existing piping surface and recognition of
reliability of the piping strength. There is no guarantee that we take responsibility for such damages.
The operational pressure of the refrigerant R410A becomes higher compared to R22. In the worst case, a lack of compressive
strength may lead to piping explosion.
3. Cleaning
· When the refrigerant oil used for the existing unit is other than the listed below, make
sure to install new piping or wash it thoroughly before reusing it.
[Mineral Oil] SUNISO, FIORE S, MS
[Synthesized oil] alkyl benzene oil (HAB, parallel freeze), ester oil, ether oil (PVE only)
If the existing unit is GHP type, it is necessary to wash the piping thoroughly.
· If the existing pipes in the outdoor and indoor units remain disconnected, make sure to
install a new piping or wash it thoroughly before reusing it.
· If the discoloured oil or residue remains in the existing piping, make sure to install a new
piping or wash it thoroughly before reusing it. See “Deterioration Criteria for Refrigerant
Oil” in table 3.
· If the compressor of the existing air conditioner has a failure history, make sure to install
a new piping or wash it through thoroughly before reusing it.
When reusing the existing piping as it is without removing dirt and dust, inadequate piping could result a renewal appliance in
failure.
NEW __ COMMERCIAL
· Only the main pipe L can be used among different diameter’s existing
piping.
· Installation work as a standard size is capable for L1, L2, l1 - l4 piping.
· Be sure to use our genuine branch piping for refrigerant R410A.
Notes on renewal for simultaneous operation of multiple units
Only main pipe is applicable for using the different diameter size.
In case of different diameter size for the branch pipes, a new installation
work for a standard size is necessary.
Be sure to use our genuine branch piping for refrigerant R410A.
Main pipe
1
L
Branch pipe
L1
1. In case of single unit
It is not necessary to charge with additional refrigerant until the chargeless
pipe length in the table 2.
If the pipe length is exceeding the charge less pipe length, charge with
additional refrigerant amount per 1 m according to the equivalent length.
L2
2
3
Notes on Renewal for Simultaneous Operation of Multiple Units
Capacity class
Standard liquid pipe size
Type 50
Ø 6,35
Type from 60 to 140
Ø 9,52
Type 200
Ø 9,52
Type 250
Ø 12,7
2. In case of simultaneous operation of multiple units
Calculate the refrigerant charging amount according to the calculating
method of the standard piping diameter.
As to the additional refrigerant charging amount per 1 m, refer to the
additional amount in the table 2.
4
Standard gas pipe size
Ø 12,7
Ø 15,88
Ø 25,4
Measurement Procedure for Renewal
Observe the following procedure when reusing the existing piping or carrying out renewal installation work.
Flowchart of Existing Piping Measures Criteria for PE1 Type and PEY1 Type Outdoor Unit
START
See Table 1 – 2
Do existing piping size and piping length satisfy the standard under the conditions?
No
Yes
Existing refrigerant piping cannot be used as is.
Make sure to install a new piping.
Can existing air conditioner run in the cooling mode?
Yes
Perform the test operation in cooling mode for over 30 minutes and collect the remaining
refrigerant without stopping operation.
No
Remove existing indoor and outdoor units
See Table 3
Level “3 Over” according to colour scale level
Check inside the piping from the pipe end.
Is the oil remained inside the piping transparent?
Collect the refrigerant by the refrigerant recovery
equipment.
Remove existing indoor and outdoor units
No
No
Yes
Is the residue inside the piping removed?
No
Yes
Has the compressor in existing air conditioner been operated without any trouble?
· Use our genuine branch piping for refrigerant R410A.
· Re-process the flare of existing piping for R410A and use
the flare nut attached to the service valve of the outdoor
unit (for R410A).
Yes
Carry out the installation work according to Installation Instructions.
Wash it thoroughly or make sure to install a new piping.
Existing refrigerant piping cannot be used as is.
Opposite side dimension of flare nut (mm)
Piping size
Ø 6,35 Ø 9.52 Ø 12.7 Ø 15.88 Ø 19.05
For R410A
26
29
22
36
For R22/R407C 17
24
27
59
R22 Renewal
Refrigerant piping size and allowable piping length
Check if reuse of existing refrigerant piping is possible based on the following chart.
The standards other than this one (difference of elevation, etc.) are identical to the requirements of ordinary refrigerant piping.
Table 1 Reusable existing piping (mm)
Material
O
External diameter
Ø 6,35
Thickness
0,80
Ø 9,52
0,80
Ø 15,88
1,00
1/2 H, H*
Ø 19,05
1,00
Ø 22,22
1,00
Ø 25,4
1,00
Ø 28,58
1,00
Ø 15,88
Ø 9,52
Ø 12,7
Ø 15,88
Ø 19,05
Ø 12,7
Ø 15,88
Ø 19,05
40 m
(30 m)
20 m
(15 m)
20 m
(15 m)
10 m
(10 m)
30 m
(20 m)
Standard
50 m
(20 m)
Ø 12,7
0,80
* It is impossible to reuse the size of Ø 19.05, Ø 22.22, Ø 25.4 and Ø 28.58 for material O. Change to material 1/2H or material H.
Table 2 - 1 Refrigerant piping size: 3,6 - 14,0 kW type (mm)
Liquid pipe
Ø 6,35
Gas pipe
Ø 9,52
Ø 12,7
Standard
PE
Type 50
40 m
(30 m)
PEY
Type 60
Type 71
10 m
(10 m)
Additional refrigerant charging
amount per 1 m
PE
Type 60
Type 71
PEY
20 g/m
25 m
(10 m)
40 g/m
10 m
(10 m)
80 g/m
Standard
50 m
(30 m)
30 m
(30 m)
10 m
(10 m)
25 m
(15 m)
Type 100
Type 125
Type 140
Standard
75 m
(30 m)
75 m
(30 m)
35 m
(15 m)
35 m
(15 m)
Type 100
Type 125
Type 140
Standard
50 m
(30 m)
50 m
(30 m)
25 m
(15 m)
25 m
(15 m)
Additional refrigerant charging
amount per 1 m
20 g/m
50 g/m
80 g/m
How to see table definition (example):
In case of type 71, standard size is liquid pipe Ø 9,52 / gas pipe Ø 15,88,
There is a limitation to liquid pipe Ø 9,52 / gas pipe Ø 12,7and to liquid pipe Ø 12,7 / gas pipe Ø 15,88,
However, they are applicable for different diameter’s pipes.
Table 2 - 2 Refrigerant piping size: 20,0 - 25,0 kW type (mm)
Liquid pipe
Ø 9,52
Gas pipe
Ø 22,22
Ø 25,4
Standard
PE
Type 200
80 m
100 m
(30 m)
(30 m)
Ø 28,58
Ø 12,7
Ø 22,22
Ø 25,4
Ø 28,58
100 m
(30 m)
50 m
(15 m)
50 m
(15 m)
50 m
(15 m)
80 m
(30 m)
Standard
100 m
(30 m)
100 m
(30 m)
Type 250
Additional refrigerant charging
amount per 1 m
40 g/m
80 g/m
Ø 15,88
Ø 22,22
Ø 25,4
Ø 28,58
65 m
(20 m)
65 m
(20 m)
65 m
(20 m)
120 g/m
Allowable
Cooling capacity down
Limited piping length
Unallowable
50 m Maximum piping length
(50 m) Charge less piping length in a single connection
Table 3 Deterioration Criteria for Refrigerant Oil
0
60
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
NEW __ COMMERCIAL
Control equipment external dimensions
Control Systems
Timer remote controller
Wireless remote controller
Separate receiver for wireless
remote controller
(CZ-RTC4)
Simplified remote controller
(CZ-RE2C2)
Remote sensor
(CZ-CSRC2)
120
4.4 x 9.4 slot
4.4 x 9.4 slot
120
24,75
System controller
Intelligent controller
Communication adapter
(CZ-64ESMC2)
(CZ-256ESMC2)
(CZ-CFUNC2)
290
270
38
18
256
38
80
8
79
R 2.5
R5
22.2
ON/OFF controller
Seri-Para I/O unit for each indoor unit
(CZ-ANC2)
(CZ-CAPBC2)
LonWorks interface
Seri-Para I /O unit for outdoor unit
(CZ-CLNC2)
(CZ-CAPDC2)
4 - Ø 5 hole
Potbellied hole (4 locations)
3 - Ø 30 hole
Detail of the
potbellied hole
Magnified view
61
PKEA dimensions
Wall Mounted PKEA
CS-E9PKEA // CS-E12PKEA
CS-E15PKEA // CS-E18PKEA
TOP view
TOP view
870
SIDE view
1070
255
FRONT view
Air intake direction
255
FRONT view
870
255
1070
295
60
Right piping
hole
Air outlet
direction
BOTTOM view
870
1070
255
106
119
60
106
119
60
REAR view
REAR view
(41-61)
590
410
CU-E9PKEA // CU-E12PKEA
CU-E15PKEA // CU-E18PKEA
TOP view
824
540
124
TOP view
68
32
160
97
875
613
131
167
131
70
38
85
151
361
330
SIDE view
FRONT view
SIDE view
SIDE view
320
299
37
37
622
FRONT view
SIDE view
30
30
320
299
622
2-way valve al liquid side
(High Pressure
42
255
60
60
(41-61)
Left piping
hole
BOTTOM view
695
695
61
75
69
23
70
25
3-way valve al gas side (Low
Pressure
2-way valve al liquid side
(High Pressure
3-way valve al gas side (Low
Pressure
Dimensions: mm
62
NEW __ COMMERCIAL
PACi Standard and Elite dimensions
Wall
Type
1 Refrigerant tubing (liquid tube)
2 Refrigerant tubing (gas tube)
3 Drain hose VP13
4 Rear panel
5 Tubing and wiring holes
36 - 50
60 - 100
Ø 6,35 (flared) Ø 9,52 (flared)
Ø 12,7 (flared) Ø 15,88 (flared)
Outer diameter Ø 18
PL BACK
Ø 80
115.9
70
8
60
230
115.9
300
1065
197.4
(2.5)
148.7
2
3
1
60
67
67
95
86
300
37.3
17.9
11
230.7
200
450
95
68
3 8 4 .3
140
48
7.5cm
0)
(Ø8
5cm
5cm
415
448.2
568.2
415
439.8
496.8
(Ø8
48
132
158
0)
5
4
Dimensions: mm
4-Way 60x60 Cassette
A
650 (ceiling opening dimension)
700
336
530 (suspension bolt pitch)
320
316
301
336
700
212
Panel center
650 (ceiling opening dimension)
7
1
530 (suspension bolt pitch)
2
148
8
A view
2
(583)
(583)
575
200
575
170
146
5
71
45
(288)
179
260
71
Dimension of Fresh air
intake duct (field
supply) connection port
31
(23)
123
31
112
ø 80
6
ole
ing h
Barr
4-ø3
4 3
283
25
44
1
2
3
4
5
6
7
8
Air intake
Discharge outlet
Refrigerant tubing (liquid tube)
Ø 6,35 (flared)
Refrigerant tubing (gas tube)
Ø 12,7 (flared)
Drain tube connection port VP25
Outer dia. Ø 32
Power supply port
Suspension bolt hole
4-11 x 26 hole
Fresh air intake duct connection port Ø 80
Adjust the suspension bolt length so that the gap from the lower ceiling surface
becomes 45mm or more, as shown in the figure at right.
If the suspension bolts is too long, it will contact the ceiling panel and the unit
cannot be installed.
Dimensions: mm
63
PACi Standard and Elite dimensions
4 Way 90x90 Cassette
X
421
1 Air inlet kit is necessary.
Filter size: 520 x 520 x 16
745
(suspension bolt pitch)
8
Ø 150
4-12x30 slot
Ø 100¹
100 - 140
319
187
B
786
(suspension bolt pitch)
Ø 6,35 (flared) Ø 9,52 (flared)
Ø 12,7 (flared) Ø 15,88 (flared)
Outer diameter 32mm
36 - 71
256
124
167
130
95
Type
A
B
860~910
(ceiling opening dimension)
130
100 - 140
860~910
(ceiling opening dimension)
36 - 71
(411)
Type
1 Air intake grill
2 Air discharge outlet
3 Refrigerant piping (liquid pipes)
4 Refrigerant piping (gas pipes)
5 Drain outlet VP50
6 Power supply port
7 Discharge duct
8 Suspension bolt hole
9 Fresh air intake duct connection port
480
7
X view
345
3
5
4
840
840
480
271
50
82
950
514
160
A
42
121
6
7
300
Less than
4-Ø3
g hole
Burrin
9
7
2
2
18
115
118
7
95
Less than
35
33.5
160
167
Less than
35
160
50
145
B
180
2
2
30
Bur
80
1
3
Ø11
950
4-Ø3
ring hole
515
115
670
850
2
Ø16
Adjust the suspension bolt length so that the gap from the lower ceiling surface
becomes 30mm or more (18mm or more from the lower surface of the body) as
shown in the figure. When the suspension bolt length is long, it hits the ceiling
panel and installation is not possible.
80
2
Dimensions: mm
Low Static Pressure Hide Away
S-36PN1E5A // S-45PN1E5A // S-50PN1E5A
S-60PN1E5A // S-71PN1E5A
S-100PN1E5A // S-125PN1E5A // S-140PN1E5A
Air flow
Air flow
Air flow
740
650 (P65 x 10)
20
45
20
960
57.5
845 (P65 x 13)
1160
1040 (P65 x 16)
20
60
31
65
65
187
32
65
55
100
55
585 (P65 x 9)
55
670
840
100
Air flow
55
55
890
1060
100
65
55
975 (P65 x 15)
1088
1260
650
30
134
23
48 65 48
32
161
58
Air flow
1320
1200
80
80
250
1120
1000
250
80
Drainage pipe connection
523
780 (P65 x 12)
Air flow
900
780
250
65
64
523
64
64
523
30
65
Drainage pipe connection
Drainage pipe connection
Dimensions: mm
64
NEW __ COMMERCIAL
High Static Pressure Hide Away
S-36PF1E5A // S-45PF1E5A // S-50PF1E5A
Filter
6
35
32
28
172
26
4
700
Inspection acces
450 x 450
(Field supply)
636
758
700
280
9
3
7
65
300
1
12 - Ø3 holes
71
1 Refrigerant tubing joint (liquid tube) Ø 6,35 flare
2 Refrigerant tubing joint (gas tube) Ø 12,7 flare
3 Upper drain port VP25
Outer diameter 32mm
200 flexible hose
supplied
4 Bottom drain port VP 25
Outer diameter Ø 32mm
5 Suspension lug
4-12 x 30mm
6 Power supply outlet
7 Fresh air intake port
Ø 150mm
8 Flange for flexible air outlet duct
9 Electrical component box
150 x 3 = 450
800
867 (Suspension bolt pitch)
5
130
30
20
8
32
30
113
256
89
71
33
(150)
70
23
140
27
186
290
23
2
(75)
154
23
592 (Flange O.D.)
77
186
54
S-60PF1E5A // S-71PF1E5A
Filter
6
172
32
28
35
280
9
26
4
700
636
700
758
3
Inspection acces
450 x 450
(Field supply)
7
65
300
1
1 Refrigerant tubing joint (liquid tube) Ø 9.52 flare
2 Refrigerant tubing joint (gas tube) Ø 15.88 flare
3 Upper drain port VP25
Outer diameter Ø
32mm 200 flexible
hose supplied
4 Bottom drain port VP 25
Outer diameter 32mm
5 Suspension lug
4-12 x 30mm
6 Power supply outlet
7 Fresh air intake port
Ø 150mm
8 Flange for flexible air outlet duct
9 Electrical component box
150 x 5 = 750
1000
1067 (Suspension bolt pitch)
5
54
792 (Flange O.D.)
32
130
30
20
150
21
33
(150)
70
23
140
27
186
290
23
2
(75)
154
27
21
16 - Ø3 holes
186
8
77
30
113
256
89
Dimensions: mm
65
PACi Standard and Elite dimensions
High Static Pressure Hide Away (Cont.)
S-100PF1E5A // S-125PF1E5A // S-140PF1E5A
Filter
6
35
32
28
172
26
4
700
Inspection acces
450 x 450
(Field supply)
636
700
758
280
9
3
7
65
32
130
71
33
(150)
66
70
23
140
27
186
290
23
2
(75)
1192 (Flange O.D.)
154
77
1 Refrigerant tubing joint Ø 9.52 flare (liquid)
2 Refrigerant tubing joint Ø 15.88 flare (gas)
3 Upper drain port VP25 O.D. Ø 32mm) 200
flexible hose
54
supplied
4 Bottom drain port VP 25 Outer diameter 32mm
5 Suspension lug
4-12 x 30mm
6 Power supply outlet
7 Fresh air intake port
Ø 150mm
8 Flange for flexible air outlet duct
9 Electrical component box
150 x 7 = 1050
1400
1467 (Suspension bolt pitch)
150
30
20
71
20 - Ø3 holes
27
8
186
30
113
256
1
300
89
5
Dimensions: mm
NEW __ COMMERCIAL
Ceiling
S-60PT2E5A // S-71PT2E5A
123
Drain port VP20
Inside diameter Ø 26mm, drain hose supplied
Left drain position
Refrigerant liquid tubing
Ø 9.52mm, flare connection
Refrigerant gas tubing
Ø 15.88mm, flare connection
Left side drain hose outlet port (cutout)
Tubing hole on wall surface Ø 100mm
Upper side tubing port
Right side drain hose outlet port (cutout)
Wireless remote controller receiver installation location
1 14
265
190
(suspension
bolt pitch)
1
2
3
4
5
6
7
8
9
61
73
7
1226 (suspension bolt pitch)
690
1
216
8
Minimum 50cm
131
193
235
Approx. 2°
4
15
1269
5
Air intake
Over
250
Air discharge
Over
250
1275
Service space
80
186
Service space
176
Tubing hole position on wall surface
(Figure shows view from front)
216
9
2
90
3
(Closed with rubber stopper
at time of shipment.) (Left
drain position)
96
6
86 (Gas tubing)
70 (Liquid tubing)
90 (Right drain position)
4
S-100PT2E5A // S-125PT2E5A // S-140PT2E5A
123
61
1 14
265
190
(suspension
bolt pitch)
73
7
1.541 (suspension bolt pitch)
690
216
1
8
Over
250
Over
250
1.590
Service space
80
186
Service space
Tubing hole position on wall surface
(Figure shows view from front)
176
Air intake
Air discharge
9
216
5
Minimum 50cm
131
193
235
Approx. 2°
4
15
1.584
2
90
(Closed with rubber stopper
at time of shipment.) (Left
drain position)
3
4
6
96
86 (Gas tubing)
70 (Liquid tubing)
90 (Right drain position)
Dimensions: mm
67
PACi Standard and Elite dimensions
High Static Pressure Hide Away 20,0-25,0 kW
178
41
4
106
5
1310
1070
10 x 100P = 1000
28-Ø3.5 (holes all around)
44
1
2
3
4
5
6
51
23
479
300
100 100 50
1
209
2
1100
1230
1170 (suspension bolt pitch)
344
2
200
250
Refrigerant liquid line
Ø 9.52
Refrigerant gas line
Ø 19.05 Ø 22.22
Power supply outlet
Drain port
Outer diameter 32 mm
Duct connection for suction
Duct connection for discharge
6
71
100 100 60
320
26-Ø3.5 (holes all around)
9 x 100P = 900
964
1200 (suspension bolt pitch)
43
67
4 - 37 x 12 (hole for suspension bolt)
67
1310
113
3
42
364
(236) 364
1334
1428
Dimensions: mm
Outdoor Unit PACi Standard 6,0 and 7,1 kW and PACi Elite 5,0 kW
608
1
Air intake
50
320
3
50 Elite
60 - 71 Standard
Ø 18
Ø 19
4-o12
Ø 12,7 (flare)
Ø 15,88 (flare)
Ø 6,35 (flare)
Ø 9,52 (flare)
336
310
285
100
46
249
(23.5)
50
46
Type
1 Drain port
2 Drain port
3 Anchor bolt hole (Anchor bolt M8)
4 Refrigerant tubing joint (gas tube)
5 Refrigerant tubing joint (liquid tube)
85
(13)
(97)
Air intake
12
50
2
27.5
2
50
Air discharge
70
109
15
51
569
790
13
12
149
(161)
4
153
5
68
25
110
(157)
Dimensions: mm
NEW __ COMMERCIAL
Outdoor unit PACi Standard 10,0 and 12,5 kW and PACi Elite 6,0 and 7,1 kW
170
620
150
500
or more
70
200
or more
Air intake side
300
410
Air outlet side
19.5
18
19.5
340
380.5
21
10
13
Air intake
Space for piping,
wiring and
maintenance
100
or more
13
Air discharge
1
38
340
76
940
31.5
61
42
2
6
7
16
3
Air intake
Air discharge
69
53
996
5
6
35
4
5
6
60
120
60
48
81
10
120
39
462
430
48
120
Z
90
60
7
26
7
16.5
24
81
39
4
60
35
86
Z VIEW
60
Dimensions: mm
1
2
3
4
5
6
7
Mounting hole (4-R6.5), anchor bolt
Refrigerant piping (liquid pipe)
Refrigerant piping (gas pipe)
Electrical wiring port
Electrical wiring port
Electrical wiring port
Electrical wiring port
M10
Ø 9,52 (flared)
Ø 15,88 (flared)
Ø 13
Ø 22
Ø 27
Ø 35
69
PACi Standard and Elite dimensions
Outdoor unit PACi Standard 14,0 kW and PACi Elite from 10,0 to 14,0 kW
170
620
150
500
or more
200
or more
70
Air intake side
21
10
13
Air intake
Space for piping,
wiring and
maintenance
100
or more
300
13
Air discharge
410
19.5
18
19.5
340
380.5
Air outlet side
1
38
340
76
940
31.5
61
42
69
16
3
5
53
1416
6
7
2
120
6
35
4
5
6
81
16.5
90
48
Z
10
120
120
48
39
522
7
60
24
81
39
490
4
Z VIEW
60
7
26
60
60
35
86
60
Dimensions: mm
1
2
3
4
5
6
7
70
Mounting hole (4-R6.5), anchor bolt
Refrigerant piping (liquid pipe)
Refrigerant piping (gas pipe)
Electrical wiring port
Electrical wiring port
Electrical wiring port
Electrical wiring port
M10
Ø 9,52 (flared)
Ø 15,88 (flared)
Ø 13
Ø 22
Ø 27
Ø 35
NEW __ COMMERCIAL
Outdoor unit Big PACi Elite 20,0 and 25,0 kW
2 x Ø 32 holes (holes for drain)
Of the 4 Ø 32 holes , use 1 of the 2 holes specified for
drain use to install the port. Use rubber plugs to seal the
remaining 3 holes.
170
660
110
26
10
Air intake
105
Type
1 Mounting hole (4-R6.5), anchor bolt
2 Refrigerant tubing (liquid tube)
3 Refrigerant tubing (gas tube)
4 Refrigerant tubing port
5 Electrical wiring port
6 Electrical wiring port
7 Electrical wiring port
8 Electrical wiring port
60
219
75
13
75
340
380
18
290
Air intake
13
Air discharge
25
M10
Ø 9,52 (flared) Ø 12,7 (flared)
Ø 19.05 (flared)
Ø 16
Ø 19
Ø 29
Ø 38
Figure
Q’ty
Reducing Joint Tube
(Ø 19.05 ➡ Ø 25.4)
1
Joint Tube (Ø 19.05)
1
Remark: There are two types of supplied tubings. The one tubing port Ø 19.05
(flare process) is connected to the flared connection of the gas port side’s
service valve. The other “L” shaped tubing port is brazed in connection after
cutting the tube at the proper length. Then make a brazing connection to the
main tubing (Ø 25.4).
40
20
1
940
340
2
Air discharge
Air intake
39
1526
3
5
6
22
22
30
30
586
7
8
42
42
6
7
8
77
60
8
Anchor bolt
111
111
77
5
25
49
49
8
4
60
57
Anchor bolt
4
85
64
A
Anchor bolt
49 61
33
43
65
62
49
VIEW A
VIEW B
Bottom removable connection port
Refrigerant tubing connection port
52
121
5.5
46
67
Anchor bolt
0
R3
3
5
80
58
7.5
7
63
410
Name
B
20
4
60
8
7
59
6
Anchor bolt
Dimensions: mm
71
72
NEW __ CONTROL AND CONNECTIVITY
CONTROL AND CONNECTIVITY
Panasonic has developed the largest range of control systems to offer the best option to each need.
From the individual remote control for the residential single units up to the newest technology to control each your buildings
around the world from an easy to use software in the cloud by your portable device.
73
Panasonic Smart Cloud
Take control of all your shops around the world from a single
device.
Centralize control of your business premises, from
wherever you are, 24/7
It doesn’t matter how many sites you have, or where they are!
The new Cloud system from Panasonic allows you to have
complete control of all your installations, from your
smartphone or from your computer. In a simple click, all your
units from several locations, receive status updates in realtime of all your installations, preventing breakdowns and
optimizing costs.
antages
Main Adv
ma
ations fro
ll
a
t
s
in
ll
,
fa
· Control o internet connection
le
g
sin
d
in the clou utomatically
a
ACi
arameters
· All the p om the GHP/ECOi/P
updated fr in real time
vice
enance ad
t
in
a
m
e
t
· Remo · Alarms
With Panasonic Smart Cloud, have your business under control, and start saving!
· Monitor temperature in your shops, optimize temperatures, reduce energy costs!
· Monitor running time, anticipate maintenance and optimise costs consumption
· Monitor breakdowns in order to take quick action to maintain the comfort in the shops
· Monitor energy consumption and running time of the units
· Compare the performance of your shops easily and develop best practices plan
· Alarms
· 2 connections possible:
- by internet, using the shop internet connection
- by 3G module. In this case, the system does not need internet connection,
but a SIM Card and the 3G contract should be supply on the field.
dule
By 3G mo
74
NEW __ CONTROL AND CONNECTIVITY
Security
Panasonic has developed both physical and software
protection with a high level of encryption to secure your
data on our servers which are located in Germany.
NEW PANASONIC Smart Cloud
Internet
Scalable solution according to the needs
Panasonic Smart Cloud is fully scalable to the needs of
your shops, franchises, facility companies.
1
Secure HTTPS
Connection
Climate
Cloud
adapter
Panasonic Smart Cloud is giving value not only for
your business but also for your partners
3
Unique
key
Climate
Cloud
adapter
3
RS485
Encrypted Channels
Based unique key of
each adapter
CLOUD PORTAL
2
RS485
Unique
key
Climate
Cloud
adapter
3
Unique
key
RS485
SHOP 1
SHOP 2
SHOP 3
CZ-CFUNC2
CZ-CFUNC2
CZ-CFUNC2
3 steps to setup the Smart Cloud
Panasonic Smart Cloud is very easy to install on
existing and new installations.
The communication adaptor (CZ-CFUNC2 + PAW-CCA-1)
is connected to the Panasonic bus and the Ethernet.
Then in only 3 steps, the cloud system is running.
1
2
POWER
Ethernet
Climate
Cloud
adapter
RS485
1) Secure connection between portal and adapters (encryption). 2) Portal: Single point of access for shops owners, employers, franchisers and
facility companies. 3) Easy integration in existing systems via RS485 protocol.
2
Climate
Cloud
adapter
Serial Number:
Adapter 1
Unit 1
Unit 2
Unit 3
Indoor unit
SHOP
Internet
CZ-CFUNC2
ADD ADAPTER
Outdoor unit
Connect Wires / Internet connection
Availability of the solution
Phase
Feature
1
On/Off of units/groups/sites
1
Set mode per units/groups/sites
1
Set temperature per units/groups/sites
1
Running time per units
1
Schedule per units/groups/sites
1
Shops status display on Map
1
Initial configuration wizard
1
Alert notifications
1
Users management
2
Advanced statistics (working hours, performance etc.)
2
Energy consumption calculation
2
Systems ranking mode based on define parameters
2
Error logs
2
Status on map
2
Email notifications
2
3-G module
3
Maintenance module
3
Energy Management module
Register adapter in Cloud
May 2014
✔
✔
✔
✔
✔
✔
✔
✔
✔
Configure units structure
September 2014
December 2014
2015
✔
✔
✔
✔
✔
✔
✔
✔
✔
1) This service is available on a 2 year base contract, with automatic renewal every year. The parties can cancel the contract at the end of the year with 3 month notice. 2) This cost only covers the activation of the system on the cloud. The 3G card and the 3G monthly
fee from the telecommunication company is not included and must be supply locally.
75
Remote controller with Econavi
Easy to use, attractive, clear design, with new demand control functions and energy consumption
display! This useful feature makes this remote control unique!
Design
The new CZ-RTC5 wired remote control is ideal for integration into the most demanding interior
architectures.
The touch panel features a very sleek and easy to use display, which with its compact display is only
120mm x 120mm x 16mm.
Display of information
The information is mainly based on pictograms to ensure easy understanding.
The minimal amount of text is available in 4 languages (English / German / French / Spanish / Italian).
The screen is back lit to enable reading even during the night.
Easy Access to the menus
With the new pictograms, the navigation, the selection and the settings are simple and easy to follow.
Key Functions
· Easy setup of the timer and settings of the indoor unit
· Energy consumption display (only available with PACi units with the reference ending with A)
· Limitation of the energy consumption (Demand control) by timer.
76
NEW __ CONTROL AND CONNECTIVITY
Basic function (Operation display & indication)
All functions are easily available on the remote controll.
· OFF/ON timer · Weekly timer · Quiet operation · Remote control sensor ·
Operation prohibit · Filter sign · Energy saving · Centralized control indication ·
Mode change prohibit · Automatic temperature return · Temperature range
limitation · OFF remind · Schedule demand control · Ventilation · Out Function
Name of the room (Max.16 characters)
Example of easy access to the functions: Energy consumption
monitoring display per day, week, month and year (only available
with PACi units)
Time & Day of the week
Mode: Hot /
Cool / Dry / Fan
Auto
Menu selection: 3 types (Day/Week/Year)of display are
available.
Daily Energy consumption: Data is shown with
Yesterday’s record.(Graph starts from 0 o’clock to 24
o’clock only.)
Weekly Energy consumption: Power consumption of
each day of the week can be checked.
Annual Energy consumption: Power consumption of
each month can be checked.
Fan speed:
H / M / L / Auto
Status: Heating
stand-by / Defrost
operation / Stand-by
(GHP system)
Set temperature
Flap setting
Easy operation and quick access to all menus
1. Set temperature will be selected, when any arrow button is touched.
2. Select the item (Mode or Fan speed) by left/right key.
3. Change the setting by up/down key.
Functions available on the CZ-RTC5
Control item
Controllability
Basic Operation
Operation, Mode, Temperature setting, Airflow
volume, Airflow direction
Time display
Easy ON/OFF timer
Weekly Program timer
Outing function
Temperature auto return
Temperature setting range limitation
OFF remind
Energy saving mode
Schedule demand control
Energy monitoring
System failure information
Service contact registration
Filter sign (rest time display) & Reset
Auto-address, Test run
Sensor value monitor
Simple/Detail setting mode
Key lock
Ventilation fan control
Display contrast adjustment
Remote controller sensor
Quiet operation mode
Prohibit setting control from Central controller
Timer function
Energy saving
Maintenance
Example of easy access to the functions: Air direction setting
1. Select “Air direction” and press “determine” key.
2. Select the unit No. by up/down key.
3. Select the flap position by up/down key.
4. Press “Return” key to go back the Menu display.
1
2
Others
3
Indoor Units
All PACi
Only PACi All VRF
ending on A
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
—
—
—
✔
✔
✔
✔
✔
✔
✔
✔
✔
—
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
—
—
—
—
—
—
—
—
✔
✔
✔
✔
✔
✔
✔
✔
✔
—
✔
All specifications subject to change without notice.
Example of easy access to the functions : Weekly timer setting
8 actions available per day. Total 56 actions per week can be set.
1. Weekly timer menu display
2. Setting for each day of the week
3. Timer program setting of the day
1
2
3
77
Up to 28%
energy savings
(cooling)
Wired remote controller CZ-RTC5
with Econavi Sensor Control
Econavi Sensor
INCREASE
EFFICIENCY
BY 28%
INCREASE
COMFORT
Econavi Sensor reference: CZ-CENSC1
The all new Econavi Sensor detects presence in the room, and quietly adapts the PACi or VRF air
conditioning system in order to improve comfort and maximise energy savings.
· Detects human activity and adjusts temperature by 2 degrees (up or down) to optimize comfort
and efficiency
· If there is no activity detected for a set time, the Econavi will stop the unit or move to a new
temperature previously set
· The Econavi device is installed independently of the indoor unit, and is located in the area best
suited for detection
Applications
Saving Energy for Offices: if the air conditioning is left on after the last employee leaves the
office, Econavi will automatically react, reducing or stopping the system.
Increased comfort in hotel rooms: when presence is detected in the room, the temperature is
automatically adjusted to achieve best comfort.
Econavi function
· Analyses room activity: Human activities and human heat
· Modifies the capacity to adapt in real-time to the needs of the room
Key points
· Compatible with Cassette, Wall Mounted, Hide Away and Ceiling · Sensor · Improves efficiency ·
Better Comfort · Can be installed in the best place of the room for detection purposes.
78
NEW __ CONTROL AND CONNECTIVITY
Human activity and presence detection
Presence detection
Activity detection
HIGHER ACTIVITY
LOWER ACTIVITY
After 20 mins absence
After 3 hours absence
Cooling Set Temp. +/-0°C
Cooling Set Temp. +1°C
Cooling Set Temp. +2°C
Cooling Thermo OFF
Heating Set Temp. -1°C
Heating Set Temp. +/-0 °C
Heating Set Temp. -2°C
Heating Thermo OFF
Each 2 min
After 3 hours set up can be change to
stop or temp shift
Sensor location image
7m
2,5 m
Detection area 6m
5m
3m
1m
1m
3m
5m
-60°
Approx 1m
60°
-40°
40°
-20°
b (m)
20°
0°
1,8m Dead Zone
Human detection area (2,5m height angle 30°)
28%
Model evaluation only for PACi (Laboratory Testing/Cooling Operation)
Test Method
To establish conditions for our field tests, because human movements and
door open/close are random, we did not test on set conditions. To replicate
typical conditions, we have fixed variable numbers (see below) and tested
how Econavi’s temperature control function contributes to energy efficiency
level.
For each temperature setting, we have tested and compared power
consumption at three-hourly intervals.
Integral Power Consumption Cooling Operation
9.000
Energy Saving
for 28%
Energy Saving
for 28%
Energy Saving
for 28%
Integral power consumption (kWh)
8.000
7.000
6.000
5.000
4.000
3.000
2.000
1.000
00
1
2
3
25°C
26°C
27°C
Remote controller setting temperature
Increasing setting
temperature +2°C
during cooling
operation, maximum
28% Energy Saving
can achieved.
ENERGY
SAVING
Test Condition
· Testing location: New 6,0HP testing room / 29m²
· Test sample remote controller setting: Setting temperature:
Cooling 24 ~28°C / Fan Speed: Hi
· Measured integral power consumption every 30 minutes and compare
(including thermo OFF period)
· Room temperatures / 19°C, outdoor temperature 35/24°C (cooling
nominal capacity) cool down the room for 1 hour and keep the room
temperature stable. After the room temperature become stable, turn OFF
indoor unit refrigerator and heater and only operate circulator and
continue cooling down the room by the unit (operating circulator to avoid
temperature variation)
Test Sample Testing Location: Building 1.460 NEW 6,0HP TESTING ROOM
Circulate air by Circulator
Installation Board
4-way Single Cassette 4,0HP
S-100PT1E5
Refrigerator
piping
PACi Elite Single 4,0HP
U-100FE1E5
Indoor setting temperature 27/19°C. Turn OFF indoor unit refrigerator and heater and continue cooling operation (circulator operation ON).
Operating time (hours)
24°C
7m
28°C
79
Operation System
Individual Control Systems
Requirements
Control for hotel application
(for VRF)
Wired remote controller
Intelligent Controller
Normal operation
NEW
External appearance
Type, model name
PAW-RE2C3-WH
PAW-RE2C3-GR
PAW-RE2C3-MOD-WH
PAW-RE2C3-MOD-GR
PAW-RE2C3-LON-WH
PAW-RE2C3-LON-GR
Stand-Alone White
Stand-Alone Grey
Modbus White
Modbus Grey
LonWorks White
LonWorks Grey
Normal operation with
Econavi
CZ-RTC2 (Will be replaced CZ-RTC4
in June by CZ-RTC4)
Design wired remote
controller
Quick and easy
operation
Wireless remote
controller
Simplified remote controller
CZ-RTC3 (Will be replaced CZ-RWSU2 // CZ-RWSY2 // CZ-RE2C2
in October by CZ-RTC5)
CZ-RWSL2 // CZ-RWSC3 //
CZ-RWST2 // CZ-RWST3 //
CZ-RWSK2
✔
✔
✔²
✔
1 indoor unit
1 group, 8 units
1 group, 8 units
—
· Up to 2 controllers can · Up to 2 controllers can · Up to 2 controllers can · Up to 2 controllers can · CZ-RE2C2: up to 2
be connected per group be connected per group be connected per group be connected per group controllers can be
connected per group
· CZ-RELC2: can not
operate other (SUB)
remo-con
✔
✔
✔
✔
✔
✔
—
✔
Econavi Control
Power consumption monitor
Built-in Thermostat
I_O which can be controlled
Use limitations
—
—
✔
Function ON/OFF
Mode setting
Fan speed setting
Temperature setting
Air flow direction
Permit/Prohibit switching
Weekly program
AUTO
✔
✔
—
✔
—
—
✔
✔
✔
✔
✔
—
✔
✔
✔²
✔
—
—
✔
—
—
✔
1 group, 8 units
1 group, 8 units
1 group, 8 units
✔
✔
✔
✔
✔
—
✔
1. Setting is not possible when a remote control unit is present (use the remote control for setting). 2) Only for PACi Elite except 50 type. * All specifications subject to change without notice.
80
Wireless remote
controller
✔
✔
✔
✔
✔¹
—
—
✔
✔
✔
✔
✔¹
—
—
NEW __ CONTROL AND CONNECTIVITY
Control systems for PACi, ECOi and ECO G
A wide variety of control options to meet the requirements of different applications.
Timer Operation
Centralized Control Systems
Daily and weekly
program
Operation with various function
from center station
NEW
Only ON/OFF operation Simplified load distribution
from center station ratio (LDR) for each tenant
BMS System. PC Base
Connection with 3rd Party
Controller
P-AIMS. Basic Software
Seri-Para I/O unit for outdoor unit
CZ-CAPDC2
CZ-CSWKC2
Schedule timer
CZ-ESWC2
System controller
CZ-64ESMC2
New System Controller
with Schedule timer
ON/OFF Controller
CZ-64ESMC3 (Available in
December 2015. Tentative
data)
CZ-ANC2
Intelligent Controller
(Touch screen panel)
Optional software
Local adaptor for ON/OFF control
CZ-CAPC2
CZ-256ESMC2 (CZ-CFUNC2)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
64 groups, max. 64 units
64 groups, max. 64 units
64 groups, max. 64 units
16 groups, max. 64 units
64 units x 4 systems, max. 256 units
CZ-CSWAC2 for Load distribution.
CZ-CSWWC2 for Web application.
CZ-CSWGC2 for Object layout
display.
CZ-CSWBC2 for BAC net software
interface.
MINI Seri-Para I/O Unit
CZ-CAPBC2
*PC required (field supply)
Web Interface Systems
CZ-CWEBC2
*PC required (field
supply)
Communication Adaptor
CZ-CFUNC2
· Required power supply
· Up to 10 controllers, can · Up to 10 controllers, can · Up to 8 controllers (4
· A communication adaptor
from the system
be connected to one
be connected to one
main units + 4 sub units) (CZ-CFUNC2) must be installed for
controller
system
system
can be connected to one
three or more systems
· When there is no system · Main unit/sub unit (1
· Main unit/sub unit (1
system
controller, connection is
main unit + 1 sub unit)
main unit + 1 sub unit)
· Use without remote
possible to the T10
connection is possible
connection is possible
controller is impossible
terminal of an indoor unit · Use without remote
· Use without remote
controller is possible
controller is possible
—
—
—
—
—
—
✔
✔
✔
✔
✔
✔¹
✔
—
✔
✔
✔
✔
✔¹
✔
✔
✔
—
—
—
—
✔
—
✔
✔
✔
✔
✔¹
✔
✔
81
Control for hotel application
Nice, easy and cost effective!
Nº1
FOR HOTEL APPLICATIONS
ALL IN ONE!
More easier to install, cheaper
to integrate one only control to
integrate all devices
Panasonic has developed an innovative line up of remote controls
specially designed for applications:
· Easy to install
· Cost effective installation as all electrical cable are centralized on this remote
· Architect inspired attractive design
· Direct connection to the Indoor unit with most of the functions of the indoor unit
· 3 options available: Stand-Alone, Modbus or LonWorks communication
· 2 frame colours: White and aluminium
From this remote control: The lighting, card contact, motion detector, window contact and
the air conditioning are controlled.
Energy saving functions included on the device: · Turns Off air conditioning and lighting
when room is unoccupied · Disables air conditioning when window is open · Maximum/
minimum setpoint temperature configurable
Easy remote control: The hotel customer will have access to limited functions to control the
air conditioning:
ON/OFF, Temperature (under a certain limit fixed during the start up) and Fan speed
Easy set up: Stand-Alone model with easy configuration menu to access all parameters. The
installation is simplified as all the cables should arrive to the remote control. A pre-define
scenario can be uploaded on the remote control connected to a computer to make installation
on site plug and play (only on the Modbus and LonWorks models).
82
NEW __ CONTROL AND CONNECTIVITY
Control to integrate all room
hotel needs in one device:
Card switch. Heating and cooling control.
Light control. Window control. Possible
to connect to Modbus
2
4
3
1. Indoor unit. Variable static
pressure hide away
2. Room card switch*
1
3. Lighting control
5
4. Human sensor
5. Window contact*
* Field supply
Four preconfigured systems (option 1 to 4)
The remote control have a 4 preconfigured systems in order to easily integrate it.
4 options available I/O configurations: Inputs
Configurations Digital
Digital
1-2
3-4
Option 1
Card
Window
Option 2
Card
Window
Option 3
Motion Sensor Window
Option 4
Lighting
Window
I/O Definitions: Inputs
Digital
5-6
Lighting
Blinds Up
Door Contact
Blinds Up
Analog
7-8
Temperature
Blinds Down
Temperature
Blinds Down
Available I/O Configurations: Outputs
Configurations Relay
15-16
Option 1
Courtesy
Option 2
Courtesy
Option 3
Courtesy
Option 4
Not used
Relay
13-14
Lighting
Lighting
Lighting
Lighting
Relay
11-12
Not Used
Blinds Up
Not Used
Blinds Up
Relay
9-10
Valve actuator
Blinds Down
Valve actuator
Blinds Down
Description
Card
Window
Lighting
Temperature
Blinds Up
Blinds Down
Motion Sensor
Door Contact
Functionality
Occupancy room status. Enable HVAC Control and automatically switches ON Courtesy and Lighting outputs
Temporary disables HVAC System
Pushbutton to turn ON/OFF Lighting Output when room occup.
Analog input for Valve Actuator output control on 2nd zone
Pushbutton for Blind Up motor output control
Pushbutton for Blind Down motor output control
In combination with Door Contact, enables HVAC Control and automatically switches ON Courtesy and Lighting outputs
In combination with Motion Sensor, enables HVAC Control and automatically switches ON Courtesy and Lighting outputs
I/O Definitions: Outputs
Description
Courtesy
Lighting
Valve Actuator
Blinds Up
Blinds Down
Functionality
Automatically turns ON when room changes to occupied or unoccupied mode. It turns to OFF after a configurable time-out
Automatically turns ON/OFF when room changes to occupied/unoccupied. Manual override with Lighting input
HVAC Control for a 2nd zone
Output for Blind Up motor control
Output for Blind Down motor control
Example I/O: Wiring configuration for Option 2
N
L
R1
R2
Indoor unit
MODBUS
A
B
16
15
14
13
Courtesy
Room
1
3
2
4
12
11
10
9
5
6
7
8
Panasonic Reference
Example I/O: Option 2
Terminals
A, B
R1, R2
1, 2
3, 4
5, 6
7, 8
9, 10
11, 12
13, 14
15, 16
Description
Modbus RS-485
Indoor Unit
Card contact
Window Contact
Blinds Up
Blinds Down
Blinds Down
Blinds Up
Lighting Room
Lighting Courtesy
Type
Bi-directional
Bi-directional
Digital Input
Digital Input
Digital Input
Analog Input
Relay Output
Relay Output
Relay Output
Relay Output
PAW-RE2C3-WH
PAW-RE2C3-GR
PAW-RE2C3-MOD-WH
PAW-RE2C3-MOD-GR
PAW-RE2C3-LON-WH
PAW-RE2C3-LON-GR
Stand-Alone with I/O White frame
Stand-Alone with I/O Grey Frame
Modbus RS-485 with I/O White frame
Modbus RS-485 with I/O Grey frame
LonWorks TP/FT-10 with I/O White frame
LonWorks TP/FT-10 with I/O Grey frame
Modbus RS-485
Twisted Pair
83
Individual Control Systems
Wired remote controller. Normal operation with Econavi (CZ-RTC4) (Available in June 2015)
NEW
· Time Function 24 hours real time clock (week day indicator)
· Weekly programme function (a maximum of 6 actions can
be programmed for each day)
· Sleeping function (this function controls the room
temperature for comfortable sleeping)
· Maximum 8 indoor units can be controlled from one
remote controller
· Remote control by main remote controller and sub
controller is possible (maximum 2 remote controllers
(main remote controller and sub controller) can be
installed for one indoor unit)
· Possible to connect to the outdoor unit using PAW-MRC
cable for servicing purposes
· Outing function (this function can prevent the room
temperature from dropping or rising when the occupants
are out for a long time)
· Dimensions (H x W x D:) 120 x 120 x 20 mm
· Weight: 160 g
Basic remote controller ON/OFF
· Econavi compatible
· Operation mode changeover (Cooling, Heating, Dry, Auto, Fan)
· Temperature setting (Cooling / Dry: 18-30 °C Heating:
16-30 °C)
· Fan speed setting High / Medium / Low and Auto
· Air flow direction adjustment
High-spec wired remote controller (CZ-RTC5) (Available in October 2015)
· Power consumption monitor (only for PACi)
· Flat face design & Touch sensor switch for stylish design
and operating usability
· New functions such as for Energy saving & monitoring
and for Service use are available on the Full dot LCD (3,5”
display)
· Improved illumination
· White LED backlit
· Blink when alarm occurs
Basic Operation
Energy saving
Others
· Operation
· Mode
· Temperature setting
· Airflow volume
· Airflow direction
· Outing function
· Temperature setting
range limitation
· Temperature auto
return
· OFF remind
· Schedule demand
control
· Energy saving mode
· Energy monitoring
· Key lock
· Ventilation fan control
· Display contrast
adjustment
· Remote controller
sensor
· Quiet operation mode
· Prohibit setting control
from Central controller
Timer function
· Outing function
· Weekly Program timer
· Easy ON/OFF timer
· Time display
* Several functions can not use on some outdoor unit. Ex. Power consumption monitor is not available
for PACi Standard, Big PACi and PACi Elite 50 type.
Timer remote controller (CZ-RTC2)
· Time Function 24 hours real time clock (week day indicator)
· Weekly programme function (a maximum of 6 actions can
be programmed for each day)
· Sleeping function (this function controls the room
temperature for comfortable sleeping)
· Maximum 8 indoor units can be controlled from one
remote controller
· Remote control by main remote controller and sub
controller is possible (maximum 2 remote controllers
(main remote controller and sub controller) can be
installed for one indoor unit)
· Possible to connect to the outdoor unit using PAW-MRC
cable for servicing purposes
Control contents
Standard Control · Control of the various operations of the indoor unit by wired or wireless remote controller.
· Cooling or heating mode of the outdoor unit is decided by the first priority of the remote controller.
· Switching between remote controller sensor and body sensor is possible.
(1) Group control · Batch remote control on all indoor units.
· Operation of all indoor cells in the same mode.
· Up to 8 units can be connected.
(2) Main/sub
· Max 2 remote controllers per indoor unit.
remote control · The button pressed last has priority.
· Timer setting is possible even with the sub remote controller.
84
· Outing function (this function can prevent the room
temperature from dropping or rising when the occupants
are out for a long time)
Basic remote controller ON/OFF
· Operation mode changeover (Cooling, Heating, Dry, Auto,
Fan)
· Temperature setting (Cooling / Dry: 18-30 °C Heating:
16-30 °C)
· Fan speed setting High / Medium / Low and Auto
· Air flow direction adjustment
Dimensions (H x W x D): 120 x 120 x 16mm
Part name, model No.
Timer remote controller: CZ-RTC4
Wired remote controller: CZ-RE2C2 // CZ-RELC2
Wireless remote controller: CZ-RWSU2 // CZ-RWSL2 // CZ-RWSG2 // CZ-RWSK2 // CZ-RE2C2
Timer remote controller: CZ-RTC4
Wired remote controller: CZ-RE2C2
Wireless remote controller: CZ-RWSU2 // CZ-RWSL2 // CZ-RWSG2 // CZ-RWSK2 // CZ-RE2C2
Main or sub. Timer remote controller: CZ-RTC4
Wireless remote controller: CZ-RWSU2 // CZ-RWSL2 // CZ-RWSG2 //
CZ-RWSK2 // CZ-RE2C2
Quantity
1 unit each
1 unit
As required
NEW __ CONTROL AND CONNECTIVITY
Wireless remote controller
CZ-RWSU2
CZ-RWSL2
CZ-RWSK2
For 4 Way 90x90 Cassette.
For 2 Way Cassette.
For Wall Mounted and 4 Way 60x60
Cassette (with panel CZ-KPY3A).
CZ-RWST2
CZ-RWST3
CZ-RWSK2 + CZ-RWSC3
For 1 Way Cassette.
For Ceiling.
Combination for all indoor units.
· Easy installation for the 4 Way cassette type simply by
replacing the corner part
· 24 hour timer function
· Remote control by main remote controller and sub
controller is possible (Max. 2 remote controllers (main
remote controller and sub controller) can be installed for
one indoor unit)
· When CZ-RWSC3 is used, wireless control becomes
possible for all indoor units (1: when a separate receiver
is set up in a different room, control from that room also
becomes possible. 2: automatic operation by means of
the emergency operation button is possible even when
the remote controller has been lost or the batteries have
been exhausted)
· Operation of separate energy recovery ventilators (When
commercial ventilation fans or heat-exchange ventilation
fans have been installed, they can be operated with this
remote control (interlocked operation with the indoor unit
or independent ventilation ON/OFF)
Simplified remote controller (CZ-RE2C2)
A remote controller with simple functions and basic
operation
· Suitable for open rooms or hotels where detailed functions
are not required
· ON/OFF, operation mode switching, temperature setting, air
speed switching, air flow direction setting, alarm display, and
remote controller self-diagnosis can be performed
· Batch group control for up to 8 indoor units
Remote sensor (CZ-CSRC2)
· This remote sensor can be connected to any
indoor unit. Please use it to detect the room
temperature when no remote controller sensor or
body sensor is used (connection to a system
without a remote controller is possible)
· For joint use with a remote control switch, use
the remote control switch as main remote
controller
· Batch group control for up to 8 indoor units
· Remote control by main remote controller and sub controller
is possible with a simplified remote controller or a wired
remote controller (up to two units)
Dimensions (H x W x D): 120 x 70 x 16mm
Remote sensor (CZ-CSRC3) (Available in July 2015)
· New appearance design based on simplified
remote controller chassis
85
Centralised Control Systems
Schedule timer (CZ-ESWC2)
The power supply for the schedule timer is taken from one
of the following.
1. Control circuit board (T10) of a nearby indoor unit (power
supply wiring length: within 200 m from the indoor unit).
2. System controller (power supply wiring length: within
100 m from the indoor unit).
When the power supply for the schedule timer is taken
from the control circuit board of the indoor unit, that indoor
unit cannot be used with other control devices using the
CZ-T10 terminal. As operation mode and temperature
settings are not possible with the schedule timer, it must
be used together with a remote controller, a system
controller, an intelligent controller, etc. Also, as it does not
have an address setting function, the control function of a
system controller etc. must be used for address setting.
· Up to 64 groups (maximum 64 indoor units) can be
controlled divided into 8 timer groups
· Six program operations (Operation/Stop/Local permission/
Local prohibition) per day can be set in a program for one
week
- Only operation or stop, remote controller local permission
or remote controller local prohibition, and their respective
combinations are possible. (Operation + local permission,
stop + local prohibition, only local permission, etc.)
- Local prohibition and the combination of the three items of
temperature setting, mode change, and operation/stop can
be set at the time of installation.
· A function for pausing the timer in case of national
holidays has been added, and timer operation also can be
stopped for a long time
- By setting holidays or operation stop within one week,
the timer can be paused just for that week.
- All timer settings can be stopped with the timer “ON/
OFF effective” button. (Return to timer operation is
made by pressing the button again.)
Dimensions (H x W x D): 120 x 120 x 16mm.
Connection example 1 (power supply from the indoor unit)
Connection example 2 (power supply from the central controller)
Indoor/outdoor
operation wire
Remote
controller
Schedule
timer
System
controller
Schedule
timer
Zone 1
Centralised
addresses
1 to 16
1
2
8
Timer group 1: Centralised
addresses 1 to 8
9
10
16
Timer group 2: Centralised
addresses 9 to 16
Zone 2
Centralised
addresses
17 to 32
17
18
24
Timer group 3: Centralised
addresses 17 to 24
25
26
32
Timer group 4: Centralised
addresses 25 to 32
Zone 3
Centralised
addresses
33 to 48
33
34
40
Timer group 5: Centralised
addresses 33 to 40
41
42
48
Timer group 6: Centralised
addresses 41 to 48
Zone 4
Centralised
addresses
49 to 64
49
50
56
Timer group 7: Centralised
addresses 49 to 56
57
58
64
Timer group 8: Centralised
addresses 57 to 64
ON/OFF controller (CZ-ANC2)
· 16 groups of indoor units can be controlled.
· Collective control and individual group (unit) control can
also be performed.
· Up to 8 ON/OFF controller (4 main, 4 sub) can be installed
in one link system.
· The operation status can be determined immediately.
Note: As operation mode and temperature settings are not possible with the ON/OFF controller, it must
be used together with a remote controller, a system controller etc.
86
Dimensions (H x W x D): 121 x 122 x 14 + 52mm
(embedding dimension).
Power supply: AC 220 to 240 V.
I/O part: Remote input (effective voltage: within DC 24 V):
All ON/OFF.
Remote output (allowable voltage: within DC 30
V): All ON, All alarm.
NEW __ CONTROL AND CONNECTIVITY
New System Controller with scheduled timer (CZ-64ESMC3 ) (available in December 2015)
NEW
System controller (CZ-64ESMC2)
Dimensions (H x W x D): 120 x 120 x 21 + 69 mm
(embedding dimension).
Power supply: AC 220 to 240 V.
I/O part: Remote input (effective voltage: DC 24
V): All ON/All OFF
Remote output (voltage-free contact): All
ON/All OFF (external Power supply within
DC 30 V, maximum 1 A).
Total wiring length: 1 km.
Individual control is possible for max. 64 groups, 64 indoor units.
Control of 64 indoor units divided into 4 zones. (One zone can have up to 16 groups,
and one group can have up to 8 units.)
Control is possible for ON/OFF, operation mode, fan speed, air flow direction (only
when used without a remote controller), operation monitoring, alarm monitoring,
ventilation, remote controller local operation prohibition, etc.
Individual All operations are possible from the remote controller. However, the
contents will be changed to the last settings used on the controller.
Central 1 The remote controller cannot be used for ON/OFF. (All other operations
are possible from the remote controller.)
Central 3 The remote controller cannot be used for mode change or temperature
setting change. (All other operations are possible from the remote
controller.)
Central 4 The remote controller cannot be used for operation mode change. (All
other operations are possible from the remote controller.)
Joint use with a remote controller, an intelligent controller, a schedule
timer, etc. is possible
(The maximum number of connectable system controllers is 10, including other
central controllers on the same circuit.)
(In case of joint use with a wireless remote controller, there are limitations for the
control mode. Please use only with “Individual” and “Central 1”.)
Control of systems without a remote controller and of main/sub systems
(a total of up to 2 units) is possible
CND2
L1
L2
B3 B2 B1 A3 A2 A1
C1
C2
C3
C4
External Contacts On Central Controllers
Terminals for remote monitoring:
A1) Input for turning ON air conditioners concurrently
A2) Input for turning OFF air conditioners concurrently
A3) Common input for turning air conditioners ON or OFF
B1) On operation state indicator output
B2) Alarm indicator output
B3) Common indicator output
A control mode corresponding to the use condition can be selected from 10
patterns
A. Operation mode: Central control mode or remote control mode can be selected
Central control mode: The system controller is used as centralised control
device. (Setting from a remote controller can be prohibited by prohibiting local
operation from the system controller.)
Remote control mode: The system controller is used as a remote controller.
(Setting from the system controller can be prohibited by prohibiting local
operation from another central control unit.)
B. Controlled unit number mode: All mode or zone 1, 2, 3, 4 mode can be selected
All mode: All, zone, or group unit can be selected.
Zone 1, 2, 3, 4 mode: Setting is possible only for the indoor units of zone 1, 2,
3, or 4.
Connection example
All mode
B
Zone 1 mode
Controlled Zone 2 mode
unit number
Zone 3 mode
mode
Zone 4 mode
A Operation mode
Central control mode
Remote control mode
All central control. Example 1
All remote control
Zone 1 central control. Example 2
Zone 1 remote control
Zone 2 central control
Zone 2 remote control. Example 3
Zone 3 central control. Example 4
Zone 3 remote control
Zone 4 central control
Zone 4 remote control. Example 5
System controller
Control mode example 2: Central control for zone 1
System controller
Individual
remote controller
Group control
Control mode example 3: Remote control for zone 2
System controller
Control mode example 4: Central control for zone 3
System controller
System without a remote controller
Control mode example 5: Remote control for zone 4
Individual remote controller
Control of a group
without remote controller
System controller
Control mode example 1: All central control
87
Centralised Control Systems
Intelligent controller (CZ-256ESMC2)
TOUCH
PANEL
Limitation contents for prohibited operation
Prohibition means limiting the operations possible from the remote
controller. It is also possible to change the prohibition items.
Limitation contents (Limitations can be user defined)
Individual No limits are set for the remote controller operation. However,
the contents will be changed to the controller’s last settings.
(Last-pressed priority.)
Prohibition 1 The remote controller cannot be used for ON/OFF. (All other
operations are possible from the remote controller.)
Prohibition 2 The remote controller cannot be used for ON/OFF, operation
mode change and temperature setting. (All other operations
are possible from the remote controller.)
Prohibition 3 The remote controller cannot be used for operation mode
change and temperature setting. (All other operations are
possible from the remote controller.)
Prohibition 4 The remote controller cannot be used for operation mode change.
(All other operations are possible from the remote controller.)
Web application
Note: Avoid joint use of the AMY system and the intelligent controller on the same indoor/ outdoor operation line.
System Configuration Example
CZ-256ESMC2
Inter-unit control
wire (non-polar)
Pulse
meter System
x3
signal
x4
Communication
adaptor control
wire (RS-485,
polar)
Linked system
No. 1
Linked system
No. 2
Inter-unit
control wire
(non-polar)
CZ-CFUNC2
Linked system No. 3
· Max. 256 indoor units (4 systems x 64 units) can be controlled. In case of
three or more systems, a communication adaptor CZ-CFUNC2 must be
installed on the outside
· Operation is possible as batch, in zone units, in tenant and in group units
· ON/OFF, operation mode setting, temperature setting, fan speed setting,
air flow direction setting (when used without a remote controller), and
remote controller local operation prohibition (prohibition 1, 2, 3, 4)
· A system without a remote controller is possible. Joint use with a remote
controller or a system controller is also possible
· Use of a schedule timer and holiday setting also can be done
· Proportional distribution of the air conditioning energy is possible.
Including CSV-file export via CF-card (supplementary accessory)
· Pulse signal input from electric/gas consumption meter
In case of joint use with a wireless remote control system, there are limitations for the control mode. Please use only with
“Permission” and “Prohibition 1”.
Pulse meter x 3
System
signal x 4 Linked system
No. 4
CZ-CFUNC2
G
W
Pulse meter
System
signal x 4
G: Gas flow meter
W: Electricity meter
Maximum number of connections
88
Independent installation without link
system connection also possible
Dimensions (H x W x D): 240 x 280 x 138mm.
Power supply: AC 100 to 240 V (50 Hz), 30 W (separate power supply).
I/O part: Remote in put (voltage-free contact): All ON/OFF.
Remote output (voltage-free contact): All ON, All alarm (external power
supply within DC 30 V, 0.5 A).
Total wiring length: 1 km for each system.
Only for embedding in the panel.
CZ-CBPCC2: Additional back up memory for CZ-256ESMC2.
Indoor units: 256 (64/link x 4)
Outdoor units: 120 (30/link x 4)
Communication adaptors: 7
Link systems (Inter-unit control wires): 4
NEW __ CONTROL AND CONNECTIVITY
Web Interface (CZ-CWEBC2)
Functions
· Access and operation by Web browser.
· Icon display.
· Language codes available in English, French,
German, Italian, Portguese, Spanish.
· Individual control possible (max. 64 indoor units)
ON/OFF operation mode, set temperature, fan
speed, Flap set, timer ON/OFF alarm code
monitoring, prohibit Remote Control.
· Zone control*.
(HxWxD): 248x185x80mm
AC 100 to 240 V (50/60Hz), 17 W
· All Units control.
(separate power supply)
· Alarm Log.
· Mail Sent Log.
· Program Timer set 50 daily timers with 50 actions each day, 50 weekly
timers 50 weekly timers, 1 holiday timer, 5 special day timers, for each
tenant
· Prohibit Remote Control settings.
· IP ADDRESS could be changed via Internet.
Web Interface Device
E mail Send
(alarm data)
LAN
Note: It is recommended to install a remote controller or a system controller on site to enable local control if it
network experience a problem.
Easy to set to every room by recognizable icon and user-friendly
remote control window
· If any of the indoor units is selected, the remote control window shown
will be displayed for detailed setting modifications.
Easy to manage and monitor each tenant use*
· Each floor or tenant, otherwise each zone can be displayed and controlled.
· All unit statuses can also be displayed on one screen.
Program Timer set
· 50 daily timers with 50 actions each day, 50 weekly timers, holiday timer,
5 special day timers, for each tenant.
* Web interface system not applicable for load distribution.
Web Interface
(CZ-CWEBC2)
Inter-unit control
wire (non-polar)
Link system
LAN (10/100BASE-T)
Functions
· Access and operation by Web browser.
· Icon display.
· Language codes available in English, French, German, Italian, Portuguese,
Spanish.
· Individual control possible (max. 64 indoor units) ON/OFF operation mode,
set temperature, fan speed, Flap set, timer ON/OFF alarm code
monitoring, prohibit Remote Control.
· Each Tenant (Zone) control.
· All Units control.
· Alarm Log.
· Mail Sent Log.
· Program Timer set 50 daily timers with 50 actions each day, 50 weekly
timers 50 weekly timers, 1 holiday timer, 5 special day timers, for each
tenant.
· Prohibit Remote Control settings.
· IP Address could be changed via Internet.
Note: it is recommended to install a remote controller or a system controller on site to enable local control if IT network experiance a
problem.
Intranet
Maximum number of connections:
Indoor units: 64
Outdoor units: 30
Link system (Indoor/outdoor control wire): 1
PC (field supply)
89
Centralised Control Systems
Seri-Para I /O unit for outdoor unit (CZ-CAPDC2 for ECOi / CZ-CAPDC3 for Mini ECOi and PACi)
Dimensions (H x W x D): 80 x 290 x 260mm.
Power supply: Single Phase 100/200V (50/60Hz), 18W.
Input: Batch operation/Batch stop (non-voltage
contact/DC 24 V, pulse signal). Cooling/Heating (nonvoltage contact/static signal). Demand 1/2 (nonvoltage contact/static signal) (Local stop by
switching)
Output:Operation output (non-voltage contact).
Alarm output (non-voltage contact)
Wiring length:Indoor/Outdoor operation lines: Total
length 1 km. Digital signal: 100 m or shorter
Seri-Para I/O Unit
for outdoor unit 1
Central Control Device
· This unit can control up to 4 outdoor units.
· From the central control device, mode changing
and batch operation/batch stop are possible.
· Required for demand control.
Seri-Para I/O Unit
for outdoor unit 2
Seri-Para I/O Unit
for outdoor unit 8
Local adaptor for ON/OFF control (CZ-CAPC2)
· Control and status monitoring is possible for individual indoor unit (or any external electrical device up to
250 V AC, 10 A) by contact signal.
CZ-CAPC2
ON/OFF controller
For example: fan coil unit etc.
Total heat exchanger unit.
Demand Control 0 -10 V (CZ-CAPBC2)
· Control and status monitoring is possible for individual indoor unit (1 group).
· In addition to operation and stop, there is a digital input function for air speed and operation mode.
· Temperature setting and measuring of the indoor suction temperature can be performed from central
monitoring.
· The analog imput for demand of the outdoor capacity by 20 steps (from 40% to 120%) by 0-10V.
· The analog input for temperature setting is 0 to 10 V, or 0 to 140 Ohm.
· Power is supplied from the CZ-T10 terminal of the indoor units.
· Separate power supply also is possible (in case of suction temperature measuring).
* Ask to your distributor.
Remote
station
CZ-CAPBC2
Central control panel
90
NEW __ CONTROL AND CONNECTIVITY
P-AIMS. Panasonic Total Air Conditioning Management System
P-AIMS Basic software / CZ-CSWKC2
Up to 1024 indoor units can be controlled by one PC.
Functions of basic software
· Standard remote control for all indoor units.
· Many timer schedule programs can be set on the calender.
· Detailed information display for alarms.
· CSV file output with alarm history, operating status.
· Automatic data backup to HDD.
With 4 upgrade packages the basic
software can be upgraded to suit
individual requirements
P-AIMS is suitable for large shopping centers and universities with many areas/ buildings. 1 “P-AIMS” PC can have 4 independent systems at once.
Each system can have max. 8 C/A units, and control max. 512 units. In total, 1024 indoor units can be controlled by 1 “P-AIMS” PC.
User PC
USB line
Converter
(Field supply)
Building A
RS485 (Polarized)
CZ-CFUNC2
CZ-CFUNC2
Building B
CZ-CFUNC2
PC Environment:
XP Professional
CPU: Pentium 2.8 GHz or over
Memory: 2 GB or over
HDD: 100 GB or over
CZ-CFUNC2
· Wiring length (PC~C/A) Max. 1 km
· Max. 8 C/A for 1 system
· Wiring length for each link from C/A Max. 1 km
CZ-CFUNC2
Building D
P-AIMS optional software CZ-CSWAC2 for Load distribution
Load distribution calculation for each tenant
· Air-conditioner load distribution ratio is calculated for each unit (tenant)
with used energy consumption data (m³, kWh).
· Calculated data is stored as a CSV type file.
· Data from the last 365 days is stored.
P-AIMS optional software CZ-CSWGC2 for Object layout display
Whole system can be controlled visually
· Operating status monitor is available on the layout display.
· Object’s layout and indoor unit’s location can be checked at once.
· Each unit can be controlled by virtual remote controller on the display.
· Max. 4 layout screens are shown at once.
P-AIMS optional software CZ-CSWWC2 for Web application
Web access & control from remote station
· Accessing P-AIMS software from remote PC.
· You can monitor/operate ECOi 6N system by using Web browser (Internet
Explorer).
P-AIMS optional software CZ-CSWBC2 for BACnet software interface
Connectable to BMS system
· Can communicate with other equipment by BACnet protocol.
· ECOi 6N system can be controlled by both BMS and P-AIMS.
· Max. 255 indoor units can be connected to 1 PC (that has P-AIMS basic
& BACnet software).
91
Centralised Control Systems
Centralised Control Systems
A custom web application to manage the centralized operation of
A2W and GHP systems.
Operation and monitoring of devices connected to the new Management
System can be realized both remotely/locally from any device with
connection to the internet (Laptop, Tablet, Mobile)
The new system will make the interaction with air conditioning systems
easier, improving the operation set as well as the global control of
installations.
The application will act with various units, regardless of whether they are
available in the same intranet or in different locations, transparently to
users at any time. In this way, our solution allows to overcome main
restrictions like onsite maintenance or the lack of centralization.
In addition, the application offers significant improvements in terms of
control:
· Aircon units can be grouped in a totally custom way
· Possibility to realize group commands and batch commands (in
succession)
· Alarms and events can be controlled more efficiently and a lot more…
Features of current system
Operation Functions
· Start & Stop
· Temperature settings
· Operation mode selection
· Fan speed, Fan direction settings
· Prohibition of use of remote
controller
Operation Monitoring
· Monitoring of operation status and
alarms
· Monitoring of filter cleaning signs
· Display of alarm logs
Current installation
Internet
Program Timers
· Up to 50 types of weekly timer
· Holiday and Special Days
Main restrictions: Decentralization: need to connect to every CZ-WEB one by one to manage installation.
On-site maintenance: Access limited to local network.
Offer reliable solution to improve existing functionalities
· Running timer
· Remote control through Web Cloud Application or local. Accessible
anytime, anywhere, via a device with internet connection
· Centralized Control: Manage several installations in one single interface.
Ideal for multi-site organizations
· Easy monitoring and maintenance thanks to group commands, and batch
commands. Easy supervision of complex installations
· Secure Remote Access. Powerful identity protection and convenient
access control
92
Benefits
The new solution for the centralized control of air conditioning systems
offers significant benefits for the different actors involved in its
management:
For the building Ownership:
· Maximum equipment performance
· Energy saving
· Increased lifetime of equipment
· Savings in maintenance costs
For Maintenance companies:
· Instant knowledge of any incident
· Possibility of preventive alarms
· Reduction of systematic visits (warning and remote control)
· More effective maintenance support
NEW __ CONTROL AND CONNECTIVITY
PACi and VRF Control
Aware of the importance of both control and connectivity in offering the
best comfort at the lowest price, Panasonic offers its customers cuttingedge technology, specially designed to ensure our air conditioning systems
deliver maximum performance. You can properly manage the air
conditioning and perform comprehensive monitoring and control, with all of
the features the remote control provides, from anywhere in the world
thanks to the internet applications Panasonic has created for you.
Internet Control
Ready
CONTROL YOUR
AIR CONDITIONING FROM
EVERYWHERE
ON
AL
Control your air conditioning system with
your smart device -smartphone & internet
for PACi and VRF Systems
Internet
Control
OP
TI
What’s Internet Control?
INTERNET CONTROL
Internet Control is a next generation system providing
user-friendly remote control of air conditioning or heat
pump units, using a simple Android or iOS smartphone, tablet or PC via
internet.
Simple Installation
Just connect the Internet Control device to the air conditioner or heat pump
with the supplied wire and then link it to your WIFI Access point.
Internet Control. Easy to install. Maximum benefit
Internet Control is underlined with the slogan “Your home in the cloud”,
meaning a simple and easy to handle solution has been considered for
every user to manage the device, not requiring any communication or
computer skills.
No servers. No adaptors. No wires. Just a small box is needed to be
connected and placed close to the air conditioning indoor unit… and your
smartphone, tablet or PC.
Your existing WiFi connection does the rest when you are at home. Start
the App from your smartphone device, your tablet or your computer, and
enjoy a new experience in comfort. And if you are out of home, just launch
the App, and manage the air conditioning of your home from the cloud. An
intuitive and user-friendly application on the screen of your smartphone or
PC that lets you manage the air conditioning unit in the same way you do
with the remote controller at home.
Internet Control can be downloaded in Apple’s AppStore and Android’s
PlayStore.
Case Study. Paul, Business Man
“My business is growing but I still want to feel like I’m in control. So I carry
out all the arrangements, transactions and operations I can from my mobile.
From bank transactions, processing orders, to controlling the temperature at
the company’s different plants; I do everything from my smartphone thanks to
IntesisHome and Panasonic.”
Case Study. Alice, Shop Owner
“I want maximum comfort and the best savings for my shop. And I manage to
get these in the easiest and most natural way possible. From my smartphone,
something I always carry with me, I can control the temperature of my shop
and in this way, as well as maintaining an ideal temperature I also save a
small fortune in electricity at the end of the year.”
Control your air conditioning with the smart internet control device
via smartphones, tablet, PC and smart desktop phone via internet
Offering the same functions as if you were at home or office: start/stop,
Mode Operation, Set Temperature, Room Temperature etc as well as the
new, advanced functionality provided by Internet Control to achieve the
best comfort and efficiency with the lowest energy consumption.
KX-UT670 Smart Desktop Phone from Panasonic.
93
PACi and VRF Connectivity
Panasonic Partners have designed solutions specifically for Panasonic air
conditioners, and provide complete monitoring, control and full
functionality of the entire Commercial line-up from KNX / Modbus /
LonWorks / BACnet installations.
PACi Connectivity
Easy connection to KNX, Modbus, LonWorks and BACnet
Interface
CZ-CFUNC2
Great flexibility for integration into your KNX / Modbus / LonWorks / BACnet
projects allows fully bi-directional monitoring and control of all the
functioning parameters.
For more information, contact Panasonic.
Communication adaptor for VRF Connectivity (CZ-CFUNC2)
This communication interface is required to connect a ECOi and GHP systems to a BMS. An additional interface is needed to convert the information into
KNX/Modbus/Bacnet language. CZ-CFUNC2 is very easy to operate and to connect to the Panasonic P-link, which is the ECOi bus. From the CZ-CFUNC2, all
the indoor and outdoor units of the installation can be easily control. Two linked wiring systems can be connected to one CZ-CFUNC2.
Dimensions: H 260 x W 200 x D 68mm
* As this is not a splash-proof design, it must be installed indoors or in the control panel, etc.
Airzone. Control of the PACi Hide Aways
Airzone has developed interfaces to easily connect to Panasonic PACi Hide Away units. Ensuring optimum performance,
comfort and energy savings, the new system is efficient and easy to install.
Airzone full range of accessories for any duct project
ON
24 °C
OFF
Different type of outlets
Also plenum
automatic doors
AIRZONE
Interface
ON
22 °C
OFF
I_U
PCB
94
Full range of RC
(wired/wireless, ...)
Room
control
Air
Outlet
NEW __ CONTROL AND CONNECTIVITY
Easy
control
by BMS
CONNECTIVITY
ECOi and GHP Connectivity
New Plug and play interface connected directly to the
P-Link
The interface has been designed specifically for Panasonic and provides
complete monitoring, control and full functionality of the Etherea, 4-Way
60x60 cassette and Low static pressure hide away line-up from
IntesisHome, KNX, EnOcean, Modbus and BacNet installations.
This connectivity solution is made by a third party company, please contact
Panasonic for more information.
ECOi /
PACi
Indoor
Units
ECOi
P-Link
Panasonic model
name
PAW-RC2-KNX-1i
PAW-RC2-MBS-1
PAW-RC2-ENO-1i
PA-RC2-WIFI-1
PAW-AC-KNX-64
PAW-AC-KNX-128
PAW-TM-MBS-RTU-64
PAW-TM-MBS-TCP-128
PAW-AC-BAC-64
PAW-AC-BAC-128
CZ-CLNC2
Interface
Connected on P-link
or in the indoor unit
KNX
Indoor unit
Modbus RTU* Indoor unit
EnOcean
Indoor unit
IntesisHome
Indoor unit
KNX**
P-link
KNX**
P-link
Modbus RTU** P-link
Modbus TCP** P-link
Bacnet**
P-link
Bacnet**
P-link
Lonworks
P-link
Maximum number of indoor
units connected
1 (1 Group of Indoor units)
1 (1 Group of Indoor units)
1 (1 Group of Indoor units)
1 (1 Group of Indoor units)
64
128
64
128
64
128
16 groupes of max. 8 indoor units,
in total max. 64 indoor units
* Interface Modbus RTU/TCP is needed in case if Modbus TCP connection. PAW-MBS-TCP2RTU (ModBus RTU Slave devices).
** Interface CZ-CFUNC2 needed.
Example of BMS connection for air conditioner central control system
Max. 64 total indoor units connected to one link on CZ-CFUNC2
BMS
system
BMS
interface
Communication
adaptor
CZ-CFUNC2
Outdoor unit
Group control
Remote controller
BMS
interface
CZ-CFUNC2
Outdoor unit
Remote controller
Group control
Max. 64 indoor units
Outdoor unit
Unit ON/OFF
A/C unit settings Mode-change
Room temperature setting
Fan speed setting
Flap setting
Central control setting
Filter-sign clear
Alarm reset
Unit ON/OFF
A/C unit status
Remote controller
Group control
Max. 64 indoor units
Operation mode
Setting temperature
Fan speed status
Flap status
Central control setting
Filter-sign situation
Correct/incorrect status
Alarm code
Outdoor unit
Remote controller
95
ECOi, ECO G and PACi Connectivity indoor units
PCB’s and cables for ECOi, ECO G and PACi indoor units
Name of the cables
Function
CZ-T10
All T10 functions
PAW-FDC
Operate external fan
PAW-OCT
All option monitoring signals
CZ-CAPE2
Option monitoring signals wo. fan
PAW-EXCT
Forced Thermo OFF/Leakage D.
Name of the PBC
Function
PAW-T10
All T10 functions
PAW-T10V
All T10 functions + powermonitoring
PAW-T10H
ON/OFF; Prohibit 5VDC & 230VAC
PAW-T10HW
ON/OFF; Prohibit 5VDC
PAW-PACR3
Redundancy of 2 or 3 systems; for ECOi and PACi
PAW-SERVER-PKEA
Redundancy of 2 units PKEA
Comment
Requires field supplied accessory
Requires field supplied accessory
Requires field supplied accessory
Requires aditional wires from spare part supply
Requires field supplied accessory
Comment
Allows easy connection “Plug & Play”
Same like PAW-T10 + monitoring the power supply of indoor unit
Specials for single hotel card or window contact
For hotel card + window contact at same time
Redundancy of 2 or 3 ECOi or PACi systems including temperature monitoring, error indication, backup, alternative run
Redundancy of 2 units PKEA including temperature monitoring, error indication, backup, alternative run
T10 connector (CN015)
CZ-T10: Panasonic has developed an optional accessory (consisting of plug +
wires) called CZ-T10 to enable an easy connection to this T10 connector.
Connecting an ECOi indoor unit to an
external device is easy. The T10 terminal
featured in the electronic circuit board of
all indoor units enables digital
connection to external devices.
T10 terminal Specification (T10: CN015 at indoor unit PCB)
· Control items: 1. Start/stop input
2. Remote controller prohibit input
3. Start signal output
4. Alarm signal output
300 ms or more
1-2 (pulse input)
+12
4-5 (output)
Example of applications
· Condition
1. 1-2 (Pulse input): Unit ON/OFF condition switching with a pulse signal.
(1 pulse signal: shortage status more than 300 msec. or more)
2. 2-3 (Static input): Open / Operation with Remote is permitted.(Normal
condition) Close / Remote controller is prohibited.
3. 4-5 (Static output): 12 V output during the unit ON. / No output at OFF.
4. 5-6 (Static output): 12 V output when some errors occur / No output at
normal.
1
· Example of wiring
COM
2
3
ON
Unit condition
OFF
4
ON
COM
NOTE: The wire length from indoor unit to the Relay must be within 2.0 m. Pulse signal
changeable to static with JP cutting. (Refer to JP001)
Usage Example
Forced OFF control
Term 1 & 2: Free contact for ON/OFF signal (cut *JP1* for static signal) when
the hotel card is it connected the contact must be close (the unit
can be used).
Term 2 & 3: Free contact to prohibit all function in the remote controller install
in the room when the hotel card is it removed the contact must be
closed (the unit can not work).
Terminal = T10
ON / OFF
COMMON
PROIBIT
OPERATION OUTPUT +12 V DC
COMMON
OUTPUT ALARM +12 V DC
96
1
2
3
4
5
6
5
+12 V
6
T10 (yellow)
Operation ON/OFF signal output
· Condition:
4-5 (Static output): 12 V output during the unit ON / No output at OFF
· Example of wiring
T10 (yellow)
1
1
2
2
3
3
4
4
5
5
6
6
Indoor unit control PCB
Relay (Field supply)
Central control
2m
RELAY 12 V DC
NOTE: The wire length from indoor unit to the Relay must be within 2.0 m. Pulse signal changeable to static with JP
cutting. (Refer to JP001)
NEW __ CONTROL AND CONNECTIVITY
Fan Drive Connector (CN032)
Option Connector (CN060) Output external signals
PAW-FDC: Panasonic has developed an optional accessory (consisting of
plug + wires) called PAW-FDC to enable an easy connection to this Fan
Drive Connector (CN032).
Operating the ventilation fan from the
remote controller
· Start / stop of external ventilation and total
heat exchanger fans
· Works even if indoor unit is stopped
· In case of group control ➔ all fans will
operate; no individual control
PAW-OCT: Panasonic has developed an
optional accessory (consisting of plug +
wires) called PAW-OCT to enable an easy
connection to this Option Connector
(CN060).
With the combination of the T10 and the option CN060 an external
control of the I_U is possible!
6P (white): Outputs external signals as shown in the figure below.
Relay (DC 12V, field supply) (Note)
OPTION
(white)
External fan On / Off
6
5
4
3
2
1
Fan signal
6
5
4
3
2
1
Heat start signal
DC 12V
Ventilation button
Cool start signal
Indoor unit control PCB (CR1)
Thermostat signal
DC 12V
FAN DRIVE
(2 plug (white))
1
1
2
2
Relay (field supply)
To external-control input
terminal on ventilation fan
Defrost signal
Indoor unit control PCB
Note: The relay must be installed at a
distance of 2 m or less from the PCB.
EXCT Connector (CN009)
PAW-EXCT: Panasonic has developed an optional accessory (consisting of plug + wires) called PAW-EXCT to enable an easy connection to this EXCT
Connector (CN009).
A) With static input
➔ STATIC INPUT ➔ THERMO OFF ➔ ENERGY SAVING
2P plug (red): Can be used for demand control. When input is present,
forces the unit to operate with the thermostat OFF.
· Examples of wiring:
Relay (field supply)
EXCT
(2P plug (red))
2
2
1
1
Relay coil signal
Note: The length of the wiring from the indoor unit control PCB to the relay must be 2m or less.
* Lead wire with 2P plug (special—order part: WIRE K/854 05280 75300)
Indoor unit control PCB
B) Example: In connection with a refrigerant sensor
· Signal from leakage detector: non voltage, static.
· Indoor unit setting: Code 0b ➔ 1
· Connector for leak detector: EXCT
· Outdoor unit setting:
Code C1 ➔ 1 power output if alarm from O2 connector 230 V
Code C1 ➔ 2 power output if alarm from O2 connector 0 V
· Displayed alarm message P14
Valves close!
Signal
Signal
CN009
Leakage!
Signal
Room 1
Room 2
Ref. detector
S
97
Notes
Notes
www.aircon.panasonic.eu
www.eggeassociats.net
Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer without
prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic Marketing Europe GmbH.
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the
damage and deterioration in safety due to usage of the other refrigerant.
The outdoor units in this catalogue contains fluorinated greenhouse gases with a GWP higher than 150.
To find out how Panasonic cares for you,
log on to: www.aircon.panasonic.eu
Panasonic Marketing Europe GmbH
Panasonic Air Conditioning
Hagenauer Strasse 43, 65203 Wiesbaden, Germany
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement