Create TruSeq DNA, RNA, or ChIP Sample Plates and Sample Sheets with IEM FOR RESEARCH USE ONLY This quick reference card describes how to use the Illumina® Experiment Manager (IEM) to create a TruSeq® DNA, RNA, or ChIP sample plate, and create and edit sample sheets compatible with your Illumina sequencing system and analysis software. For more detailed general information on how to use the IEM application and definitions of the sample sheet applications, see the Illumina Experiment Manager User Guide (part # 15031335). New or less experienced users are advised to read the guide before using this quick reference card. 7 For each well that contains a sample, do the following: a Enter a unique sample ID. b Specify what index adapter you intend to use for each Index Read. c If you want to capture more detailed information about the plate, enter a sample name, project, and description. 8 [Optional] Click the Plate Graphic tab to view the sample ID and index adapter in each well. a If you want to copy an image of your sample plate for use in a presentation or paper, select Copy to Clipboard on the Plate Graphics tab. You can paste the image into any graphics-enabled program, such as Paint, Microsoft PowerPoint, Microsoft Word, and Adobe Photoshop. b If you want to print an image of your sample plate, select Print... on the Plate Graphics tab. 9 Click Finish and save the sample plate file. NOTE • For TruSeq Targeted RNA Expression, see Create TruSeq Targeted RNA Expression Sample Plates and Sample Sheets with IEM (part # 15041979)). • For TruSeq Synthetic Long-Read DNA sample plates and sample sheets, see Create TruSeq Synthetic Long-Read DNA Sample Plates and Sample Sheets with IEM (part # 15069713). Create a Sample Plate WARNING The sample plate file must contain the following file extensions: *.tru0.plt for LT plates with no indexes *.tru16.plt for LT plates with a single index *.truht0.plt for HT plates with no indexes *.truht18.plt for HT plates with a single index *.truht28.plt for HT plates with dual indexes NOTE A sample plate is not required to generate a sample sheet, but can be useful for organizing samples. 1 Open the IEM software. 2 On the IEM main screen, select Create Sample Plate. 3 On the Sample Prep Kit Selection screen, select from the following, depending on which kit type you are using: • TruSeq LT for TruSeq v2, LT, NeoPrep, or ChIP samples • TruSeq HT for TruSeq HT samples 4 Click Next. 5 On the Assay Parameters screen, do the following: a In the Unique Plate Name field, type a name for the sample plate. b In the Index Reads field, select the number of indexes to run for the samples on this plate: 0, 1, or 2 (2 indexes option for TruSeq HT only). c Click Next. 6 On the Plate Samples screen, select the Table or Plate tab. You can enter information for the wells in your plate using either view. Part # 15037152 Rev. E Create a Sample Sheet This section provides instructions for creating a sample sheet for the analysis of MiSeq®, HiSeq®, HiScanSQ™, Genome Analyzer™, or NextSeq™ sequencing data. Create a MiSeq-Compatible Sample Sheet 1 On the IEM main screen, select Create Sample Sheet. 2 On the Instrument Selection screen, select MiSeq, and then select Next. 3 On the MiSeq Application Selection screen, select the desired category and application for your kit, and then select Next. 1 of 3 Create TruSeq DNA, RNA, or ChIP Sample Plates and Sample Sheets with IEM For TruSeq DNA, RNA, and ChIP products, the following categories and applications are supported: Category Application Targeted Resequencing Clone Checking Small Genome Sequencing Click Add Selected Samples. 8 [Optional] Click Add Blank Row to add rows and manually enter the sample information. 9 Type a sample name, sample project, and description for each sample. Metagenomics 16s rRNA 10 Click Finish and save the sample sheet file. Resequencing 11 When prompted, select Yes if you want to review the sample sheet in Microsoft Excel or No to exit the sample sheet wizard without reviewing the sample sheet. Assembly Plasmids RNA Sequencing RNA-Seq Create a HiSeq-, HiScanSQ-, or Genome AnalyzerCompatible Sample Sheet Other Library QC 1 On the IEM main screen, select Create Sample Sheet. ChIP-Seq (TruSeq LT only) 2 On the Instrument Selection screen, select HiSeq, HiScanSQ, GA, and then select Next. 3 On second the Instrument Selection screen, select HiSeq 3000, 4000HiSeq 1500, 2500HiSeq 1000, 2000HiScanSQ, or Genome Analyzer, and then select Next. 4 On the HiSeq Application Selection screen, select the desired application, and then select Next. For TruSeq DNA, RNA, and ChIP products, the following applications and workflows are supported. FASTQ Only 4 7 On the Workflow Parameters screen, do the following: a In the Reagent Cartridge Barcode field, enter the barcode number of the MiSeq reagent cartridge. b On the Sample Prep Kit Selection screen, select from the following, depending on which kit type you are using: — TruSeq LT for TruSeq v2, LT, NeoPrep, or ChIP kits — TruSeq HT for TruSeq HT kits c In the Index Reads field, select the number of indexes you will run for the samples: 0, 1, or 2 (2 indexes with TruSeq HT only). d Type an experiment name, investigator name, and description. e Select the date. f Select a Paired End or Single Read sequencing run. g Select the number of cycles for each read in your sequencing run, plus 1. If you are performing a paired-end sequencing run, Illumina recommends performing the same number of cycles in both reads. h Check or uncheck the Workflow-Specific Settings checkboxes, as desired. i Click Next. 5 On the Sample Selection screen, select Select Plate and navigate to a sample plate you created previously. If you have not yet created a sample plate, you can do so now by selecting New Plate. 6 Click Select All to include all wells in this sequencing run or highlight the wells you want to include in this sequencing run. 2 of 3 Sample Prep Kit Option Application in Analysis Workflow IEM in Sample Sheet TruSeq LT TruSeq HT 5 Human Genome Resequencing Resequencing HiSeq FASTQ Only GenerateFASTQ On the Workflow Parameters screen, do the following: a In the Reagent Kit Barcode field, enter the reagent kit ID from the label of box 1 or box 2 of the SBS kit. b From the Sample Prep Kit drop-down menu, select from the following, depending on which kit type you are using: — TruSeq LT for TruSeq v2, LT, NeoPrep, or ChIP kits — TruSeq HT for TruSeq HT kits c In the Index Reads field, select the number of indexes you will run for the samples: 0, 1, or 2 (2 indexes option with TruSeq HT only). d Type an experiment name, investigator name, and description. e Select the date from the calendar. f Select a Paired End or Single Read sequencing run. Part # 15037152 Rev. E Create TruSeq DNA, RNA, or ChIP Sample Plates and Sample Sheets with IEM g h i Select the number of cycles for each read in your sequencing run, plus 1. If you are performing a paired-end sequencing run, Illumina recommends performing the same number of cycles in both reads. Select or clear the Workflow-Specific Settings checkboxes, as desired. Click Next. 6 On the Sample Selection screen, select Select Plate and navigate to the sample plate you created previously. If you have not yet created a sample plate, you can do so now by selecting New Plate. 7 For each lane you are using in the flow cell, do the following: a Click the lane number: 1 through 8 on the sample sheet area of the screen. b Click Select All to include all wells in this sequencing run or highlight the wells you want to include in this sequencing run. c Click Add Selected Samples. d [Optional] Click Add Blank Row to add rows and manually enter the sample information. 8 Type a sample name, sample reference, sample project, and description for each sample in each lane. 9 When the wells and samples for every lane in the flow cell have been defined, select Finish and save the sample sheet file in the desired folder. 10 When prompted, select Yes if you want to review the sample sheet in Microsoft Excel or No to exit the sample sheet wizard without reviewing the sample sheet. Create a NextSeq-Compatible Sample Sheet 1 On the IEM main screen, select Create Sample Sheet. 2 On the Instrument Selection screen, select NextSeq, and then select Next. 3 On the NextSeq Application Selection screen, select the NextSeq FASTQ Only application for the GenerateFASTQ workflow, and then select Next. 4 On the Workflow Parameters screen, do the following: a In the Reagent Kit Barcode field, enter the reagent kit ID from the label of either box 1 or box 2 of the SBS kit. b From the Sample Prep Kit drop-down menu, select from the following, depending on which kit type you are using: — TruSeq LT for TruSeq v2, LT, NeoPrep, or ChIP kits — TruSeq HT for TruSeq HT kits c d e f g h i In the Index Reads field, select the number of indexes you will run for the samples: 0, 1, or 2 (2 indexes option with TruSeq HT only). Type an experiment name, investigator name, and description. Select the date from the calendar. Select a Paired End or Single Read sequencing run. Select the number of cycles for each read in your sequencing run, plus 1. If you are performing a paired-end sequencing run, Illumina recommends performing the same number of cycles in both reads. Check or uncheck the Workflow-Specific Settings checkboxes, as desired. Click Next. 5 On the Sample Selection screen, select Select Plate and navigate to the sample plate you created previously. If you have not yet created a sample plate, you can do so now by selecting New Plate. a Click Select All to include all wells in this sequencing run or highlight the wells you want to include in this sequencing run. b Click Add Selected Samples. c [Optional] Click Add Blank Row to add rows and manually enter the sample information. 6 Type a sample name, sample reference, sample project, and description for each sample. 7 When the wells and samples have been defined, select Finish and save the sample sheet file in the desired folder. 8 When prompted, select Yes if you want to review the sample sheet in Microsoft Excel or No to exit the sample sheet wizard without reviewing the sample sheet. Technical Assistance For questions, see Illumina Experiment Manager on www.illumina.com. If you do not find the information you need there, contact Illumina Technical Support by email or phone. Copyright and Trademarks © 2015 Illumina, Inc. All rights reserved. Illumina, 24sure, BaseSpace, BeadArray, BlueFish, BlueFuse, BlueGnome, cBot, CSPro, CytoChip, DesignStudio, Epicentre, GAIIx, Genetic Energy, Genome Analyzer, GenomeStudio, GoldenGate, HiScan, HiSeq, HiSeq X, Infinium, iScan, iSelect, MiSeq, NeoPrep, Nextera, NextBio, NextSeq, Powered by Illumina, SeqMonitor, SureMDA, TruGenome, TruSeq, TruSight, Understand Your Genome, UYG, VeraCode, verifi, VeriSeq, the pumpkin orange color, and the streaming bases design are trademarks of Illumina, Inc. and/or its affiliate(s) in the U.S. and/or other countries. All other names, logos, and other trademarks are the property of their respective owners. 3 of 3
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement