Daewoo DWC-121CS Service manual


Add to my manuals
24 Pages

advertisement

Daewoo DWC-121CS Service manual | Manualzz

Manual de servicio

Acondicionador de Aire Tipo Ventana

Modelo:

DWC-121C/121CS

DWC-124C/124CS

DWA-121C/121CS

DWA-122C/122CS

DWA-124C/124CS

DWB-121C/121CS

DWB-122C/122CS

DWB-124C/124CS

DWB-123C/123CS

DWA-150C/150CS

DWA-151C/151CS

DWA-152C/152CS

TABLE OF CONTENTS

1. PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2. GENERAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3. NAMES OF MAJOR COMPONENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4~5

4. FUNCTION OF MAIN COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

5. GENERAL INFORMATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

6. CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

7. TROUBLE SHOOTING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

8. HOW TO DISASSEMBLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

9. WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

10. REFRIGERANT CYCLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

11. EXPLODED DIAGRAM AND PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

1

1. PRECAUTION

Please observe the following instructions.

1. Turn off unit.

Make sure the unit is OFF and the AC cord is unplugged before repairing or servicing.

2. In case of checking the circuit unavoidably while the unit is connected with power source, be careful not to connect with the part of electric charge.

You may cause electric shock.

3. Use of proper part if you need to replace the part, be sure to use genuine part of servicing model.

Do not repair or replace the electric contact part.

Consumer must not repair the unit, because it is dangerous.

4. Use of proper tool.

You must use the proper tool to repair the unit, and use the measuring appliance adjusted accurately.

5. Damage of electric wire and power cord when servicing.

Check electric wire and a surely replace a damage electric wire and a damage power cord.

6. Never use connecting the middle of wire, after cutting the middle of wire.

It may cause a fire and trouble.

7. Checking the insulation resistance.

After you complete the assembly of unit, surely check the insulation resistance.

Confirm that the insulation resistance of the power line and the ground terminal is over 30M

Ω by measuring insulation resistance.

8. Checking the ground.

After checking the ground, servicing it completely.

9. Checking the installation.

After checking the installation, servicing it completely.

10. Care children.

When servicing, do not make the children approach the air-conditioner.

2

2. GENERAL SPECIFICATIONS

ITEM

Function

Power source

MODEL

Cooling

Capacity

Energy

Efficiency

Ratio

Btu/h

Kcal/h

Btu/wh

Kcal/wh

Dehumidification

Electrical

Data

Pts/h g/h

Power Input (W)

Running Current (A)

DWC-121C/CS

(DWC-124C/CS)

AC 115V, 60Hz

12,100

3,050

10.1

2.55

3.40

1,545

1,200

11.5

DWA-121C/CS

12,000

3,024

10.2

2.57

3.61

1,640

1,175

5.5

DWA-122C/CS

(DWA-124C/CS)

DWB-121C/CS

AC 208~230V, 60Hz

12,000

3,024

10.1

2.55

3.14

1,427

1,184

5.5

Cooling only

AC 220~240V, 50Hz AC 220~230V, 50Hz AC 240V, 50Hz

11,700

2,950

9.9

2.49

3.30

1,500

1,180

5.2

DWB-122C/CS

(DWB-124C/CS)

DWB-123C/CS DWA-150C/CS

DWA-151C/CS

(DWA-152C/CS)

12,000

3,024

10.0

2.52

2.66

1,209

1,150

5.4

11,500

2,898

10.0

2.52

2.71

1,232

1,150

5.4

AC 208~230V, 60Hz

14,018

3,533

9.4

2.38

4.04

1,836

1,487

6.7

14,000

3,528

9.8

2.47

3.93

1,786

1,420

6.5

Compressor

Motor

Type Rotary

Model

Capacitor

Model

Capacitor

QK164CN12 QK164KN12 RBA115A001 QK196PN13A RBB110A011 RBF110A011 QJ196KC23 RCA135A001

40µF/370VAC

AM12DWD10/

OBM-2501K1

12µF/370VAC

25µF/370VAC

AM12DWD12/OBM-2502U1

5µF/370VAC

35µF/400VAC 30µF/400VAC 35µF/400VAC

A2925CA070/OBM-2501P2

5µF/400VAC

25µF/370VAC

AM12 DWD11/OBM-2503U1

4µF/370VAC

Indoor-Fan Blower-Fan

Outdoor-Fan Propeller-Fan

Refrigerant

(R-22)

Control Capillary

Dimensions

Weight

Charge Q’ty (g) 24.0 oz (680g) 26.1 oz (740g) 27.9 oz (790g) 25.7 oz (730g) 24.3 oz (690g) 26.8 oz (760g) 27.9 oz (790g) 27.5 oz (780g)

Unit (WxHxD) 23.6(W) x 14.9(H) x 21.0(D) Inch (600(W) x 380(H) x 535(D) mm)

Packing (WxHxD) 26.1(W) x 18.1(H) x 22.6(D) inch (663(W) x 460(H) x 573(D) mm)

Net Weight 88 lbs (38.8Kg) 88 lbs (38.8Kg) 90.2 lbs (39.8Kg) 92 lbs (42Kg)

Gross Weight 89 lbs (40.3 Kg) 89 lbs (40.3 Kg) 97.5 lbs (43 Kg) 96 lbs (43.5Kg)

• DWA-124C/CS, DWB-124C/CS, DWC-124C/CS, DWA-152C/CS;

Except detachable Double Grille Front, the general spec of this model is same to one of the old models.

3

3

1

2

3.NAMES OF MAJOR COMPONENTS

• DW ✻ -121C / DW ✻ -122C / DWB-123C / DWA-150C / DWA-151C

9

3

10

7

11

4

8

1

2

5 6 5 6

• DW ✻ -121CS / DW ✻ -122CS / DWB-123CS / DWA-150CS / DWA-151CS

9

3

1

2

NO PART NAME

1 AIR FILTER

2 GRILL FRONT

3 CABINET

4 BLADE VERTICAL

5 KNOB THERMOSTAT

6 KNOB SELECTOR

NOTE: ✻ → A or B or C

5

12

6

3

10

7

11

4

8

1

2

5

12

6

NO PART NAME

7 BLADE HORIZENTAL

8 AIR VENT

9 PLATE WINDOW TOP

10 FRAME WINDOW KIT

11 SHUTTER WINDOW

12 AUTO LOUVER S/W (DW ✻ -121CS/DW ✻ -122CS/DWB-123CS/DWA-150CS/DWA-151CS)

7

4

8

4

7

4

8

• DW ✽ -124C / DWA-152C

0

3

2

1

5 6 9

• DW ✽ -124CS / DWA-152CS

0

3

2

1

5 6 e

9

NO PART NAME

3

4

1

2

AIR FILTER

GRILLE

CABINET

BLADE VERTICAL

5

6

KNOB THERMOSTAT

KNOB SELECTOR

7 BLADE HORIZENTAL

NOTE: ✽→ A or B or C q

7

4 w

8

2

3

1

5 6 9 q

7

4 w

8

2

3

1

5 6 e

9

NO PART NAME

8

9

AIR VENT

FRAME GRILLE

10 FRAME GUIDE TOP

11 FRAME WINDOW KIT

12 SHUTTER WINDOW

13 AUTO LOUVER S/W (DW ✽ -124CS/DWA-152CS)

7

4

8

5

7

4

8

4. FUNCTION OF MAIN COMPONENTS

1. ROTARY SWITCH (SELECTOR)

Please refer to the part of selector in the chapter 9 (Wiring Diagram).

The rotary switch (selector) controls the fan motor’s rotation speed, and has six positions.

The function of the six position is as follow.

OFF: This position stops all operations of the air conditioner.

HIGH COOL: This position provides the maximum air flow for rapid cooling, dehumidifying and dust removing operations.

(Use this position on sultry summer days.)

MED COOL: This position provide the medium air flow for cooling dehumidifying and dust removing operations

LOW COOL: This position provides the minimum air flow for quiet cooling, dehumidifying operations.

(Use this position on suitable for night-time.)

HIGH FAN: This position provides the maximum air fiow alone fan operation without cooling operation.

LOW FAN: This position provides the minimum air flow air flow alone fan operation without cooling operation.

2. THERMOSTAT (TEMPERATURE CONTROL)

The Thermostat automatically starts and stops operation in order to keep the room temperature at a proper level, and this results in efficient use of power and economical cooling.

Turn clockwise for a cooler room temperature.

Turn counter-clockwise for a warmer room temperature.

3. MOTOR

The motor is used to rotate the indoor and outdoor fan so that the room air can be recirculated.

4. FAN

BLOEWR FAN: The Blower draws hot air from the room through the Evaporator and then discharges it back into the cool air. It circulates the room air.

PROPELLER FAN: The propeller draws outdoor air through louvering and cools Condenser, and then blows the hot air out.

5. CAPACITOR

The Capacitor enlarges the difference of phase between main coil and sub coil so that the Compressor and Fan Motor starts well.

6. ACCUMULATOR

The Accumulator blocks the unflow of liquid refrigerant and impurities into the Compressor.

6

5. GENERAL INFORMATIONS

1. CHANGING AIR FLOW DIRECTION

Air flow deflectors divert air from center flow to left or right and up or down.

Adjust deflectors for desired air flow pattern.

2. AIR FLOW AROUND UNIT

Check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow. If air flow is obstructed or deflected back into unit, the compressor may cycle on and off rapidly, causing early compressor failure.

3. Electrical Grounding Instructions.

This appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a twoprong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the twoprong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National

Electrical Code.

4. USE OF EXTENSION CORDS

Because of potential safety hazards under certain conditions we strongly recommend against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL listed 3-wire grounding type appliance extension cord rated has a 3-blade grounding plug and a 3-slot receptacle that will plug into appliance.

5. DRAIN HOLE AND WATER DRIPPING OUTSIDE

Locate drain hole at the rear of unit. Water in base pan is picked up by the fan blade and thrown onto the warm outdoor coil where it evaporates. The air conditioner must be installed level or tited or slightly to the outside for proper water disposal. On exceptionally hot and humid days the air conditioner may permit excess water to pass thru rear drain hole or overflow. This should be considered normal.

7

6. CARE AND MAINTENANCE

1. AIR FILTER

Clean the air filter, which removes dust inside the room.

It should be washed at least once every week during operation.

• All models except DW*-124C/CS, DWA-152C/CS ( ✽→ A or B or C)

1. Remove the Air Filter from the front grill by pulling to right.

2. Clean Air Filter with a vacuum cleaner or lukewarm, soapy water.

3. Shake it when clean to remove moisture completely. Reinstall.

• Only DW*-124C/CS, DWA-152C/CS ( ✽→ A or B or C)

1. Open the inlet grille upward by pulling out the bottom of the inlet grille, lift it.

2. Using the tab, pull up slightly on the filter to release it and pull it down.

3. Clean Air Filter with a vacuum cleaner or lukewarm, soapy water.

4. Shake it when clean to remove moisture completely. Reinstall.

2. CLEANING THE AIR CONDITIONER

1. At least once a year, remove cabinet and thoroughly clean air conditioner. Have the unit inspected by an authorized servicer to ensure unit is functioning properly.

2. Wash air conditioner with lukewarm, soapy water as needed. Rinse and dry thoroughly.

3. If using concentrated liquid detergent, dilute in warm water first.

4. Front grill may be wiped off with a cloth dampened in a mild detergent solution.

5. Cabinet may be washed with mild soap or detergent and lukewarm water, then polished with liquid wax for appliances.

6. Condenser and Evaporator coils should be cleaned at the beginning of each cooling season. Use a soft brush or vacuum cleaner to clean them, making sure that the Condenser and Evaporator coils are not damaged.

7. Do not use abrasive cleaners. These items scratch, crack and discolor surfaces.

8

7. TROUBLE SHOOTING GUIDE

TROUBLE

Fan motor and compressor do not run

Switch is in “cool” position but the compressor does not run

SITUATION

1. Power failure

ANALYSIS

1) Power plug

CAUSE

1) Power failure

REMEDY

Consult your electric company

2) Circuit breaker 2) Circuit breaker is tripped

3) Power plug is not contacting

2. Power is supplied, but the equipment does not run

1) receptacle

2) Operation switch

Disconnection

Mechanical failure of switch

1. Not operating at all

3) Cord or lead wire to the switch

1) Disconnection

2) Malfunction of contact

1) Compressor Disconnection or burned-out

2) Thermostat 1) Failure

2) Malfunction

3) Knob is not set to the proper setting

2. Compressor

3. Frequent start and stop

In case of a breaker, turn it on and off a few times

Replace the power plug

Repair or replace the receptacle

Replace the cord or lead wire

Replace the compressor or connection wire

Replace

Repair or replace

Turn knob for cooler setting

3) Selector switch

4) O.L.P

5) Capacitor

Failure of malfunction of proper setting

Repair or replace the swtting

Repair

1) Disconnection

Repair or replace

2) Malfunction of contact

Replace

Lack of capacity

Disconnection Repair

1) Electricity 1) The voltage exceeded allowed range

Consult your electric company

Check the capacity of wire

2) Capacity of wire is not sufficient Ventilate well and remove the heat source

Extremely high 2) Room temperature and outside temperature Burned-out Replace

3) Compressor

4) O.L.P

5) Capacitor

1) Thermostat

Malfunction

Lack of capacity

Replace

Replace

2) Capacitor

3) O.L.P

Malfunction

Lack of capacity

Malfunction

Replace

Replace

Replace

9

TROUBLE

The compressor runs but the motor doesn’t run

Vibration & Noise

Water leakage into room

Electric shock

(Leakage of current)

SITUATION

Both fan motor and compressor are running but cooling is bad

Not cooling at all

Insufficient cooling

ANALYSIS

1) Fan

2) Fan motor

3) Capacitor

4) Fan motor circuit

Refrigerant system

1) Refrigerant system

2) Filter

3) Heat exchanger of condenser

CAUSE

Blocked by others

REMEDY

Repair

Replace the fan motor Disconnection or burned-out electric cord

Failure malfunction of contact Replace

Disconnection of malfunction of contact

Check the circuit

1) Refrigerant system is choked

2) Compressor failure

3) Leakage of refrigerant gas

1) Refrigerant system is choked

2) Compressor failure

3) Leakage of refrigerant gas

4) Refrigerant charge is too high

Repair

Repair

Recharge refrigerant gas

Check and repair refrigerant system

Replace

Check a part of Leakage and repair

Repair and recharge

Clogged up with dust

1) Fin is cogged up with dust

2) The ventilation is not good

3) The unit is exposed to the sunlight

4) Other heat source is added in the room

Clean the air fiter

Clean the unit

Shade the unit from the sunlight

Remove the added heat source

1) Installation place

2) Fan

3) Fixing screws

4) Electric components

Installation of the unit is imperfectly done

1) Fan is contacted with obstacles

2) Fixing bolt

Have a screw loose

Electrical noise

Install the unit perfectly

Remove obstacles

Tighten the bolt

Tighten the screw

Exchange the components

Installation condition The front is lower than rear side Make rear side of the unit lower than the front

Insulation of components

1)Insulation defect of wiring and lead wire

2) Leakgae of current due to the dew or rust

Check the unit’s Leakage of current.

Replace the defective parts or components

10

8. HOW TO DISASSEMBLE

Please refer to the chapter 11 (Exploded diagram and parts list).

(NOTE: ✽→ A or B or C)

1 Before service of any part.

1. Stop the unit, remove the power cord from the receptacles.

2. Move the unit to the safe location for the suitable work.

2

3

Ass’y Fan Motor

- Fan Motor

- Propeller Fan

- Blower Fan

• Only DW*-124C/CS, DWA-152C/CS

1. Remove Front Grille

- Open the grille upward by pulling out the bottom of the grille, lift it.

- Remove screw which fasten Frame Grille with driver.

- Pull knobs out of the control.

(when the knobs are too tight to release, leave them.)

- Disassemble Frame Grille from chassis.

• All models except DW*-124C/CS, DWA-152C/CS

1. Remove Front Grille.

- Remove Filter Pre.

- Remove screw(2 point) in Front Grille with driver.

- Disassemble Front Grille from chassis.

2. Remove the unit from Cabinet.

- Remove screws (2 point) from the unit’s sides.

- Pull the unit from cabinet.

3. Remove Holder Scroll.

4. Remove Scroll upper

5. Remove Ass’y Control Box

- Remove screws (4 point).

- Remove wires in the each components.

6. Remove wires in the Panel Housing.

7. Remove screws (4 point) from Ass’y Fan Motor’s sides.

- Ass’y Fan Motor is assembly of Fan Motor, Propeller and Blower Fan,

Orifice and Panel Housing.

8. Lift the Ass’y Fan Motor from the unit.

9. Remove Clip Fan (2 point) from the shaft of Fan Motor.

10. Remove Propeller Fan from the shaft of Fan Motor.

11. Remove Blower Fan from the shaft of Fan Motor.

12. Remove Fan Motor from Panel Housing.

- Remove screws (4 point).

1. Same as the procedure 1 to 5 in the Item 2.

4

Ass’y Control Box

- Rotary Switch (selector)

- Thermostat

- Capacitor

- Power Cord

O.L.P

1. Same as the procedure 1 to 2 in the Item 2.

2. Remove Terminal Cover from Compressor.

- Remove hex-nut (1 point).

11

• HOW TO REMOVE THE FRONT GRILLE FOR ALL MODELS EXCEPT DW ✽ -124C/CS,

DWA-152C/CS

1. Pull the Air-filter out of the Front Grille.

2. Loosen screw which fasten Front Grille with driver.

3. Pull knobs out of the control.

(when the knobs are too tight to release, leave them.)

4. Disassemble Front Grille from Chassis.

– Front Grille and chassis are fixed with snap-fit.

1) Release right-lower snap-fit.

– Push the right lower side of chassis to the left, with pushing left side of Front

Grille to the right until the snap-fit is released.

Push

2) Release left-lower snap-fit.

– Push the left-lower side of chassis to the right, with pushing right side of Front

Grille to the right until the snap-fit is released.

Push

3) Pull lower side of the Front Grille until it is separated from the chassis. (when knobe remain, pull Front Grille until knobs are released from control)

Push

Push

4) Push base side of the Front Grille to upper side until it is separated from the chassis.

5) After front grille is removed, remove two screws located in both side of chassis.

6) Grip the handle of base pan and pull out the unit from chassis.

12

• HOW TO REMOVE THE FRONT GRILLE FOR ONLY DW ✽ -124C/CS, DWA-152C/CS

1. Open the grille upward by pulling out the bottom of the grille, lift it.

2. Remove screw which fasten Frame Grille with driver.

3. Pull knobs out of the control.

(when the knobs are too tight to release, leave them.)

4. Disassemble Frame Grille from Chassis.

– Frame Grille and chassis are fixed with snap-fit.

1) Release right-lower snap-fit.

– Push the right lower side of chassis to the left, with pushing left side of Frame Grille to the right until the snap-fit is released.

Push

2) Release left-lower snap-fit.

– Push the left-lower side of chassis to the right, with pushing right side of Frame

Grille to the right until the snap-fit is released.

Push

3) Pull lower side of the Frame Grille until it is separated from the chassis. (when knobe remain, pull Frame Grille until knobs are released from control)

Push

Push

4) Push base side of the Frame Grille to upper side until it is separated from the chassis.

5) After frame grille is removed, remove two screws located in both side of chassis.

6) Grip the handle of base pan and pull out the unit from chassis.

13

9. WIRING DIAGRAM

• DW ✻ -121C / 122C / 123C / 124C / 150C / 151C / 152C WIRING DIAGRAM

(3103523900)

WHT(BLU) 1 6

SELECTOR SWITCH

OFF

HIGH

COOL

MED

COOL

LOW

COOL

LOW

FAN

MED

FAN

4

YEL

RED

8

GRY

7 2 BLU

O.L.P

BLK

R

COMP

C

RED

H

C

F

ORG

BLK(BRN)

CAPACITOR

S

FAN

MOTOR

YEL

GRN(GRN/YEL)

WHT

THERMOSTAT

SWITCH

BLU

L C

• DW ✻ -121CS / 122CS / 123CS / 124CS / 150CS / 151CS / 152CS WIRING DIAGRAM

(3103523910)

WHT(BLU) 1 6

SELECTOR SWITCH

OFF

HIGH

COOL

MED

COOL

LOW

COOL

LOW

FAN

MED

FAN

4

BLK

SWING

MOTOR

AUTO

LOUVER

BRN

SWITCH

WHT

8

7 2

O.L.P

BLK

R

COMP

C

RED

H

C

F

ORG

BLK(BRN)

CAPACITOR

S

FAN

MOTOR

YEL

GRN(GRN/YEL)

WHT

THERMOSTAT

SWITCH

BLU

L C

YEL

RED

GRY

BLU

NOTE:

✻ → A or B or C

14

10. REFRIGERANT CYCLE

Evaporator

Blower fan

Accumulator

Compressor

M MOTOR

Propeller fan

Capillary tube

Condenser

15

11. EXPLODED DIAGRAM AND PARTS LIST.

■ DWA-121C/CS,DWA-122C/CS(124C/CS),DWB-121C/CS,DWB-122C/CS(124C/CS),DWB-123C/CS,

DWC-121C/CS(124C/CS), DWA-150C/CS,DWA-151C/CS(152C/CS) PARTS LIST

Caution:

In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr)

NO CODE COMPONENTS Q'TY

3102402400 GRILLE FRONT 1 HIPS

1

3112200400 FRAME GRILLE 1 HIPS

1-1 3112401600 GRILLE 1 HIPS

2 3103400700 KNOB 2 HIPS

SPECIFICATION

3

4

3101600600 DECORATE FRONT

3101601200 DECORATE FRONT

3101902100 FILTER PRE

3111901400 FILTER PRE

3106501800 BLADE VERTICAL 5

6

7

3106501700 BLADE HORIZENTAL

3108503600 SEAL GRILLE

3108100900 PAN BASE

8

3108100910 PAN BASE

3107400800 ASS'Y EVAPORATOR 9

10 3104421100 PIPE EVA IN

1 PC FILM

1 PC FILM

1 HIPS

1 HIPS

1 HIPS

2

1

1

1

1

1

PP(H-540)

F-US

SGCC T1.0

SGCC T1.0

2R2C, ø9.52

C1220T-O OD9.52

11 3100063600 PIPE EVA OUT AS

12 3104421700 PIPE EVA OUT 1

3104423100 PIPE SUCTION

13 3100023120 PIPE SUCTION

3104423110 PIPE SUCTION

3100061600 PIPE CAPILLARY AS

1

1

1

C1220T-O OD9.52

C1220T-O OD9.52

C1220T-O OD12.7

1 C1220T-O OD12.7

1 C1220T-O OD12.7

1 C1220T-O ID1.6L800

14 3100061620 PIPE CAPILLARY AS

3100061610 PIPE CAPILLARY AS

3100064700 COMP AS

15

3100069400 COMP AS

3107103300 COMP AS

3100069600 COMP AS

3107103400 COMP AS

3100071100 COMP AS

3107103200 COMP AS

3107103210 COMP AS

16 3104425800 PIPE DISCHARGE

1 C1220T-O ID1.6L600

1 C1220T-O ID1.6L900

1

1

1

1

1

LG-QK164CN12

1 LG-QK164KN12

1 DW-RBA115A001

1 LG-QJ196KC23

1 DW-RCA135A001

LG-QK196PN13A

DW-RBB110A011

DW-RBF110A011

C1220T-O OD7.94

NOTE: ✽→ A or B or C

16

REMARK

ALL MODELS EXCEPT DW*-124C/CS,DWA-152C/CS

DW*-124C/CS,DWA-152C/CS(ONLY)

DW*-124C/CS,DWA-152C/CS(ONLY)

DW*-121C,122C,123C,124C,150C,151C,152C(ONLY)

DW*-121CS,122CS,123CS,124CS,150CS,151CS,152CS(ONLY)

ALL MODELS EXCEPT DW*-124C/CS,DWA-152C/CS

DW*-124C/CS,DWA-152C/CS(ONLY)

DW*-121C/CS,122C/CS,123C/CS,124C/CS(ONLY)

DWA-150C/CS,151C/CS,152C/CS(ONLY)

DW*-121C/CS,124C/CS(ONLY)

DWA,B-122C/CS,123C/CS,124C/CS(ONLY)

DWA-150C/CS,151C/CS,152C/CS(ONLY)

DWA,C-121C/CS,124C/CS(ONLY)

DWA-150C/CS,151C/CS,152C/CS(ONLY)

DWB-121C/CS,DWA,B-122C/CS,123C/CS,124C/CS(ONLY)

DWC-121C/CS,124C/CS(ONLY)

DWA-121C/CS(ONLY)

DWA-122C/CS,124C/CS(ONLY)

DWA-150C/CS(ONLY)

DWA-151C/CS,152C/CS(ONLY)

DWB-121C/CS(ONLY)

DWB-122C/CS,124C/CS(ONLY)

DWB-123C/CS(ONLY)

DW*-121C/CS,DWC-124C/CS(ONLY)

NO CODE COMPONENTS

3104425820 PIPE DISCHARGE

16 3104425810 PIPE DISCHARGE

3104425830 PIPE DISCHARGE

17

3100063500 PIPE COND OUT AS

3100063510 PIPE COND OUT AS

3100063400 PIPE COND IN AS

18 3100063410 PIPE COND IN AS

3100063420 PIPE COND IN AS

19 3106800300 ASS'Y CONDENSOR

19-1 3108504300 SEAL COND TOP

20 3101202800 CLIP FAN

21 3101802600 PAN BLOWER

22 3101404100 COVER MOTOR

23 3104202000 PANEL HOUSING

24 3102000500 FIXTURE RUBBER

24-1 3100000010 BUSHING GUIDE

3108004920 MOTOR FAN

3108005020 MOTOR FAN

3108006000 MOTOR FAN

25 3108005110 MOTOR FAN

3108006100 MOTOR FAN

3108005220 MOTOR FAN

3108006200 MOTOR FAN

26 7007501211 SCREW HEX

27 3101802700 FAN PROPELLER

28 3102201100 WINDOW KIT FRAME(L)

29 3102201000 WINDOW KIT FRAME(R)

30 3100604200 PLATE WINDOW TOP

31 3100801400 CABINET ASSY

32 3100604300 BRACKET WINDOW LOWER

33 3100604500 BRACKET SILL

34 3106600600 SCROLL LOWER

35 3103700100 LEVER VENT

36 3103700100 WASHER VENT

37 3104600100 RING VENT

NOTE: ✽→ A or B or C

Q'TY SPECIFICATION

1 C1220T-O OD7.94

1 C1220T-O OD7.94

1 C1220T-O OD7.94

1 C1220T-O OD7

1 C1220T-O OD7

1 C1220T-O OD7

1 C1220T-O OD7

1 C1220T-O OD7

1 3R2C, ø7

1 F-US

2 SK-5

1 ABS

1 EPS

1 SGCC T1.0

REMARK

DWA,B-122C/CS,123C/CS,124C/CS(ONLY)

DWA-150C/CS(ONLY)

DWA-151C/CS,152C/CS(ONLY)

DW*-121C/CS,122C/CS,123C/CS,124C/CS(ONLY)

DWA-150C/CS,151C/CS,152C/CS(ONLY)

DW*-121C/CS,122C/CS,123C/CS,124C/CS(ONLY)

DWA-150C/CS(ONLY)

DWA-151C/CS,152C/CS(ONLY)

1 NBR

1 NBR

1 DAEWOO MOTOR (AM 12DWD10) DWC-121C/CS,124C/CS(ONLY)

1 DAEWOO MOTOR (AM 12DWD12) DWA-121C/CS,DWA-122C/CS,124C/CS(ONLY)

1 OBM2502U1 DWA-121C/CS,DWA-122C/CS,124C/CS(ONLY)

1 DAEWOO MOTOR (A9525CA070) DWB-121C/CS,DWB-122C/CS,123C/CS,124C/CS(ONLY)

1 OBM2501P2 DWB-121C/CS,DWB-122C/CS,123C/CS,124C/CS(ONLY)

1 DAEWOO MOTOR (AM 12DWD11) DWA-150C/CS,151C/CS,152C/CS(ONLY)

1 OBM2503U1 DWA-150C/CS,151C/CS,152C/CS(ONLY)

4 5x12 MFZN

1 ABS+GF20%

1 HIPS

1 HIPS

1 SGCC T1.2

1 SGCC T0.8

2 SGCC T0.8

2 SGCC T1.6

1 EPS

1 PP

1 PP

1 NBR

17

NO CODE COMPONENTS

38 3106700400 CAM

39 5S10405620 S/W ROCKER

40 3107000100 CLIP THERMO

41 5S0101800 THERMOSTAT AS

42 5S10405100 SWITCH ROTARY

3101300300 POWER CORD

43 3103001600 POWER CORD

3101300600 POWER CORD

3109503100 CAPACITOR

3109503110 CAPACITOR

3109503200 CAPACITOR

3109503210 CAPACITOR

3109505100 CAPACITOR

44 3109505110 CAPACITOR

3109507700 CAPACITOR

3109507710 CAPACITOR

3109507000 CAPACITOR

3109507010 CAPACITOR

3109503410 CAPACITOR

45 3101201600 CLAMP CAPACITOR

3108004800 MOTOR SWING

46 3108009700 MOTOR SWING

47 3100508500 BOX CONTROL

48 3106600500 SCROLL UPPER

49 3103002800 HOLDER SCROLL

50 3104409300 PIPE RUBBER BUTYL

3102707500 HANESS COMP AS

51 3102708801 HANESS COMP AS

52 3103200500 CAP DRAIN

53 3101404200 COVER ORIFICE

NOTE:

→ A or B or C

Q'TY SPECIFICATION

1 POM

1 R19A-2(250VAC6A)

1 ABS

1 PFA-602GF-02(PCC)

1 SR6B-416-10D

1

1

1

KKP-30B,13A 125V

WS-001I 250V 13A

KKP-4819R 250V 10A

REMARK

DW*-121CS,122CS,123CS,124CS,150CS,151CS,152CS(ONLY)

DW*-121CS,122CS,123CS,124CS,150CS,151CS,152CS(ONLY)

DWC-121C/CS,124C/CS(ONLY)

DWA-121C/CS,122C/CS,124C/CS,150C/CS,151C/CS,152C/CS(ONLY)

DWB-121C/CS,DWB-122C/CS,123C/CS,124C/CS(ONLY)

1 12/40µF,370VAC DWC-121C/CS,124C/CS(ONLY)

1 12/40µF,370VAC DWC-121C/CS,124C/CS(ONLY)

1 5/25µF,370VAC DWA-121C/CS,122C/CS,124C/CS(ONLY)

1 5/25µF,370VAC

1 5/35µF,400VAC

1 5/35µF,400VAC

1 5/35µF,400VAC

1 5/35µF,400VAC

1 5/30µF,400VAC

1

1

5/30µF,400VAC

4/25µF,370VAC

1 SGCC T0.8

1 120VAC 60HZ

1 200/220V 50/60HZ

DWA-121C/CS,122C/CS,124C/CS(ONLY)

DWB-121C/CS,123C/CS(ONLY)

DWB-121C/CS,123C/CS(ONLY)

DWB-121C/CS,123C/CS(ONLY)

DWB-121C/CS,123C/CS(ONLY)

DWB-122C/CS,124C/CS(ONLY)

DWB-122C/CS,124C/CS(ONLY)

DWA-150C/CS,151C/CS,152C/CS(ONLY)

DWC-121CS,124CS(ONLY)

DWA-121CS,122CS,124CS,150CS,151CS,152CS

DWB-121CS,122CS,123CS,124CS(ONLY)

1 SGCC T0.8

1 EPS

2 SGCC

1

1 UL1015-14,BLK,RED,WHT

1 UL1015-16,BLK,RED,WHT

DWC-121C/CS,124C/CS(ONLY)

DWA-121C/CS,122C/CS,124C/CS,150C/CS,151C/CS,152C/CS

DWB-121C/CS,122C/CS,123C/CS,124C/CS(ONLY)

1 ABS

1 PP(H-540)

18

■ DWA-121C/CS, DWA-122C/CS, DWB-121C/CS, DWB-122C/CS, DWB-123C/CS, DWC

C/CS, DWA-151C/CS EXPLODED DIAGRAM

■ DW ✻ -124C/CS, DWA-152C/CS EXPLODED DIAGRAM (NOTE: ✻ → A or B or C)

S/M NO.: DWC121C040

DAEWOO ELECTRONICS CO., LTD.

686, AHYEON-DONG MAPO-GU SEOUL, KOREA

C.P.O. BOX 8003 SEOUL, KOREA

TELEX: DWELEC K28177-8

CABLE: “DAEWOOELEC”

FAX: 02) 590-6291

TEL: 02) 360-7114/590-6151~5 http://www.dwe. daewoo.co.kr

PRINTED DATE: APR. 2002

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project