M0070-71C-511 Model: M98 70

Model: 70 Watts M98 M0070-71C-511 60 Hz Pulse Start Metal Halide Input Volts 120 208 240 277 HX-HPF Wiring Diagram HX-HPF Circuit Type 0.91 Power Factor Regulation Line Volts ±5% Lamp Watts -9% +8% Line Current (Amps) Operating 0.75 0.44 0.38 0.33 Open Circuit 1.60 0.95 0.80 0.70 Starting 1.20 0.60 0.50 0.35 4 3 3 2 Recommended Fuse UL Temperature Ratings Insulation Class H (180°C) Coil Temperature Code A A A A Benchtop Coil Rise Primary 68 58 56 56 Benchtop Coil Rise Secondary 61 - - 56 85 85 86 85 80 135 165 180 min 1.25 0.70 0.60 0.50 max 2.00 1.20 1.00 0.90 min 0.60 0.35 0.30 0.25 max 1.00 0.60 0.50 0.45 Input Watts 250 1.55 NOM Open Circuit Volts Current Crest Factor Input Voltage at Lamp Dropout Min Ambient Starting Temp. -20°F -30°C High Potential Test (Volts) 1 Minute 1650 1 Second 2000 Open Circuit Voltage Test (Volts) 230 - 280 Open Circuit Voltage Input Current Short Circuit Current Test (Amps) Secondary Current 0.95 - 1.25 Input Current Core and Coil Specifications Dimension A" 1.44 Dimension B" 2.75 Weight (lbs.) 4.6 Lead Lengths (in) 12 Capacitor Specifications Microfarads 8 Volts (min.) 280 Case Size (in.) Height ( in.) Temp Rating °C Oval OIL Filled 1.25 DRY Film 1.5 3.13 3.23 90 100 Starter Specifications Model Number ST1001 BTL 20 Temp Rating °C 105 Rev. Date: 1/30/2009 Starter Case Drawing Test Ref.: - 1090-912001-001 Specifications subject to change without notice. Howard Industries, Inc. Ballast Products Division P.O. Box 1590 Laurel, MS 39441 Phone: 1-800-956-3456 Fax: (601) 422-1652 www.howard-ballast.com