Bard PA13362-A Specifications
PA13-SERIES PACKAGED AIR CONDITIONERS
Cooling Capacities:
SEER: 13.0
23,000 to 56,500
GREEN REFRIGERANT R-410A
FRONT (INDOOR AIRFLOW) END OF UNIT
BACK (OUTDOOR AIRFLOW) END OF UNIT
Standard Engineered Features
Air Conditioner Compressor:
Reciprocating compressors with
crankcase heaters are standard on 2,
2½ and 3-ton models. Scroll
compressors are used on all other
models and no crankcase heaters
are required.
R-410A Refrigerant:
Designed with R-410A (HFC) nonozone depleting refrigerant in
compliance with the Montreal protocol
and 2010 EPA requirements.
ECM Indoor Blower Motor:
Features an electronically commutated
motor providing super-high efficiency,
low sound levels and soft-start
capabilities. The motor is selfadjusting to provide the proper airflow
rate for a broad range of static
pressure in ducted installations without
user adjustment or wiring changes.
Aluminum Finned Copper Coils:
Grooved tubing and enhanced
louvered fin for maximum heat
transfer and energy efficiency.
Outdoor coil is constructed with
special corrosion resistant
hydrophilic fin stock with 2-layer
coating. (1st layer - blue acrylic
primer; 2nd layer - clear topcoat.)
Thermal Expansion Valves:
Models with reciprocating
compressors have bleed TXV,
models with scroll compressor have
non-bleed TXV.
Discharge Muffler:
Standard on 2½ and 3-ton models.
Field Installed Accessories
Compressor Control Module:
Built-in off-delay timer adjustable from
30 seconds to 5 minutes. 2-minute
on-delay if power interrupt. 120second bypass for low pressure
control, and both soft and manual
lockouts for high and low pressure
controls. Alarm output for alarm relay.
Optional Field Installed Electric Heat
Strips:
With automatic limit and thermal cutoff.
• Field installed heater package for all
models.
• Features slide-in field assembly with
various BTUH outputs.
• Permits stocking of only one unit.
Phase Rotation Monitor:
Standard on all 3-phase models.
Protects against reverse rotation if
power supply is not properly
connected.
Optional Field Installed Low Ambient
Control:
Cycles outdoor fan motor below 55°F
outdoor temperature to maintain acceptable
condensing pressure.
High & Low Pressure Switches are
Auto-Reset
Built-in lockout circuit resets from the
room thermostat. Provides commercial
quality protection to the compressor.
Pre-Painted 20 Gauge Zinc Coated
Steel Cabinet:
Cleaned, rinsed, sealed and dried
before the polyurethane primer is
applied. The cabinet is handsomely
finished with a baked on textured
enamel, which allows it to withstand
1000 hours of salt spray tests per
ASTM B117-03.
Pre-Painted 16 Gauge Zinc Coated
Unit Base:
The unit base is treated with the
same paint coatings as the cabinet
above, insuring years of service.
Top Discharge Outdoor Fan:
Efficiently moves air quietly for
effective heat exchange.
Electrical Components & Controls:
Readily accessible for easier service.
Liquid Line Filter Drier:
Protects system against moisture.
Form No.
Supersedes
Page
S3383-509
S3383-908
1 of 8
Cooling Capacities and Efficiency Ratings
P h ase
B TU H
PA13242-A
MODELS
1
23,000
SEER
13.00
PA13302-A
1
29,000
13.00
PA13362-A, -B
1 and 3
34,000
13.00
PA13422-A, -B, -C
1 and 3
43,000
13.50
PA13482-A, -B, -C
1 and 3
46,500
13.00
PA13602-A, -B, -C
1 and 3
56,500
13.00
Tested and Certified in accordance with ARI Standard 210/240-2003.
General Specifications
Model
Electric Rating –
60 Hz – Circuit A
PA13242-A PA13302-A PA13362-A PA13362-B PA13422-A PA13422-B PA13422-C PA13482-A PA13482-B PA13482-C PA13602-A PA13602-B PA13602-C
230/208-60-1 230/208-60-1 230/208-60-1 230/208-60-3 230/208-60-1 230/208-60-3
460-60-3
230/208-60-1 230/208-60-3
460-60-3
230/208-60-1 230/208-60-3
460-60-3
197 - 253
197 - 253
197 - 253
187 - 253
197 - 253
187 - 253
414 -506
197 - 253
187 - 253
414 -506
197 - 253
187 - 253
414 -506
Minimum Circuit Ampacity 4
15
18
24
16
33
23
12
33
29
14
39
26
17
BC SC
9
11
15
10
21
15
8
22
14
8
26
16
9
Field Wire Size 3
12
10
8
12
10
10
14
8
10
12
8
10
10
Operating Voltage Range
Ground Wire Size
12
10
8
12
10
10
14
8
10
14
8
10
12
Delay Fuse – Max. 2
20
25
35
20
50
35
15
50
40
20
60
40
25
10.8/11.8
13.3/14.8
16.4/18.4
17.0/13.3
16.2/18.1
14.1/15.4
10.4
23.0/24.7
16.9/18.0
10.7
25.3/28.9
17.7/19.9
11.9
Total unit Amps – 230/208
Compressor – Circuit A
Compressor Type
Recip.
Recip.
Recip.
Recip.
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Volts
230/208
230/208
230/208
230/208
230/208
230/208
460
230/208
230/208
460
230/208
230/208
460
Rated Load Amps
7.5/8.5
9.5/11
12/14
7.6/8.9
11.8/13.7
8.3/9.6
7.7
17/18.7
10.9/12
7.7
19.3/22.9
11.7/13.9
8.6
Lock Rotor Amps
48/48
57/57
74/74
75/75
115/115
115/115
50
117/117
83.1/83.1
50
134/134
110/110
52
Fan Motor – HP
1/6 - 825
1/6 - 825
1/6 - 825
1/6 - 825
1/4 - 825
1/4 - 825
1/4 - 825
1/4 - 825
1/4 - 825
1/4 - 825
1/4 - 825
1/4 - 825
1/4 - 825
Fan Motor Amps
1.1
1.1
1.1
1.1
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
Fan – Dia./CFM
24"/2700
24"/2600
24"/2600
24"/2600
24"/3400
24"/3400
24"/3400
24"/3400
24"/3400
24"/3400
24"/3400
24"/3400
24"/3400
3/4 - ECM
Fan Motor and
C o n d en ser
Motor and Evaporator
Blower Motor – HP 1
1/3 - ECM
1/2 - ECM
1/2 - ECM
1/2 - ECM
1/2 - ECM
1/2 - ECM
1/2 - ECM
3/4 - ECM
3/4 - ECM
3/4 - ECM
3/4 - ECM
3/4 - ECM
Blower Motor – Amps
2.2
2.7
3.3
3.3
3.9
3.9
3.9
4.5
4.5
4.5
5.0
5.0
5.0
Charge (R-410 oz.)
75
85
120
120
160
160
160
160
160
160
160
160
160
Shipping Weight (pounds)
360
410
410
410
440
440
490
440
440
490
450
450
500
1
2
3
4
ECM = Electronically Commutated Motor
Maximum time delay fuse or HACR type circuit breaker for protection of field wiring devices.
Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to National Electric Code (latest revision), Article 310 for power
conductor sizing.
Indoor Blower Performance 1
MODEL
1
2
3
4
Rated
ESP
MAX
ESP
2
Continuous
Airflow
3
Rated
Cooling
C FM
4
Rated
Electric Heat
C FM
PA1324
0.10
0.50
600
800
1000
PA1330
0.15
0.50
750
1000
1000
PA1336
0.15
0.50
825
1100
1100
PA1342
0.20
0.50
925
1400
1400
PA1348
0.20
0.50
1025
1550
1750
PA1360
0.20
0.50
1150
1750
1750
Motor will deliver consistent CFM through voltage supply range with no deterioration (197-253V for all 230/208V models).
Continuous CFM is the total air being circulated during continuous (manual fan) mode.
Will occur automatically with a call for “Y” for cooling mode operation.
Will occur automatically with a call for “W1” for heating mode operation.
Form No.
S3383-509
Supersedes S3383-908
Page
2 of 8
Optional Field Installed Electric Heater Packages
Optional field-installed electric heater packages are available for 5 through 15Kw
capacities. The heater packages are UL listed to be field-installed into the basic unit.
They feature prewired control circuit wiring with plug-in connector. Simply slide the
heater into the unit, plug in the pretested control circuit and connect the separate high
voltage circuit wiring.
IMPORTANT: While this electrical data is presented as a guide, it is important to
electrically connect properly sized fuses and conductor wires in accordance with the
National Electrical Code and all existing local codes.
Optional Field Installed Heater Packages Are Only To Be Used With The Models
As Indicated Below
Heater
P ackag e
Model
Volts &
P h ase
PA13242-A PA13302-A PA13362-A PA13362-B PA13422-A PA13422-B PA13422-C PA13482-A PA13482-B PA13482-C PA13602-A PA13602-B PA13602-C
EHP323-A05 240/208-1
X
X
X
EHP323-A10 240/208-1
X
X
X
X
X
EHP323-A15 240/208-1
EHP323-B09 240/208-3
X
EHP323-B15 240/208-3
X
EHP513-A05 240/208-1
X
X
X
EHP513-A10 240/208-1
X
X
X
EHP513-A15 240/208-1
X
X
X
EHP513-B09 240/208-3
X
X
X
EHP513-B15 240/208-3
X
X
X
EHP513-C09
460-3
X
X
X
EHP513-C15
460-3
X
X
X
Optional Field Installed Electric Heater Table — 2 through 5 Ton
Heater
P ackag e
Model No.
Unit
Volts
P h ases
Htr. KW & Capacity Htr. KW & Capacity
@ 240 Volts (480)
@ 208 Volts
240/208V
Htr.
Amps
KW
B TU H
KW
B TU H
(480)
EHP323-A05 240/208-1
5
17,100
3.75
12,800
20.8/18.1
EHP323-A10 240/208-1
10
34,100
7.50
26,000
41.6/36.2
EHP323-A15 240/208-1
15
51,200
11.25
38,400
62.5/54.1
EHP513-A05 240/208-1
5
17,100
3.75
12,800
20.8/18.1
EHP513-A10 240/208-1
10
34,100
7.50
26,000
41.6/36.2
EHP513-A15 240/208-1
15
51,200
11.25
38,400
62.5/54.1
EHP323-B09 240/208-3
9
30,700
6.75
23,000
21.7/18.7
EHP323-B15 240/208-3
15
51,200
11.25
38,400
36.2/31.2
EHP513-B09 240/208-3
9
30,700
6.75
23,000
21.7/18.7
EHP513-B15 240/208-3
15
51,200
11.25
38,400
36.2/31.2
EHP513-C09
480-3
9
30,700
10.8
EHP513-C15
480-3
15
51,200
18
Heater
Internal
Circuit
Breaker
30/60
30/60
None
None
None
Circuit B
N o.
Field
Circuits
2
2
3
1
Min.
Max. Over Field Ground
Current Pow er
Wire
Circuit
Siz e
Ampacity Protection Wiring
1
26/23
30/25
10/10
10
1
53/46
60/50
6/8
10
1
79/68
80/70
4/4
8
1
26/23
30/25
10/10
10
1
53/46
60/50
6/8
10
1
79/68
80/70
4/4
8
1
28/24
30/25
10/10
10
1
46/39
50/40
8/8
10
1
28/24
30/25
10/10
10
1
46/39
50/40
8/8
10
1
14
15
14
14
1
28
30
10
12
1 Maximum size of the time delay fuse or HACR circuit breaker for protection of field wiring devices.
2 Based on wire suitable for 75°C. Other wiring materials must be rated for marked “Minimum Circuit Ampacity” or greater. Based on 75°C copper wire. All wiring
must conform to the National Electric Code and all local codes.
3 These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), Article 310 for
power conductor sizing.
IMPORTANT:
While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor
wires in accordance with the National Electrical Code and all existing local codes.
Form No.
Supersedes
Page
S3383-509
S3383-908
3 of 8
Form No.
S3383-509
Supersedes S3383-908
Page
4 of 8
29,000
20,100
30,750
20,250
34,350
20,450
36,700
26,450
38,950
26,650
43,550
26,850
41,700
45,450
44,250
45,650
49,400
46,100
52,450
38,700
55,650
39,000
62,150
39,350
55,700
41,300
59,050
41,600
66,000
41,950
64,550
46,250
68,450
46,600
76,450
47,000
30,100
Total C ooli ng
Sensi ble C ooli ng 20,600
Total C ooli ng
31,900
Sensi ble C ooli ng 20,750
Total C ooli ng
35,600
Sensi ble C ooli ng 20,900
Total C ooli ng
38,150
Sensi ble C ooli ng 27,050
Total C ooli ng
40,400
Sensi ble C ooli ng 27,300
Total C ooli ng
45,050
Sensi ble C ooli ng 27,500
Total C ooli ng
43,200
Sensi ble C ooli ng 48,150
Total C ooli ng
45,750
Sensi ble C ooli ng 48,400
Total C ooli ng
51,050
Sensi ble C ooli ng 48,850
Total C ooli ng
54,250
Sensi ble C ooli ng 39,500
Total C ooli ng
57,400
Sensi ble C ooli ng 39,900
Total C ooli ng
64,050
Sensi ble C ooli ng 40,200
Total C ooli ng
57,550
Sensi ble C ooli ng 42,200
Total C ooli ng
60,850
Sensi ble C ooli ng 42,600
Total C ooli ng
67,900
Sensi ble C ooli ng 42,950
Total C ooli ng
66,400
Sensi ble C ooli ng 46,950
Total C ooli ng
70,250
Sensi ble C ooli ng 47,450
Total C ooli ng
78,350
Sensi ble C ooli ng 47,800
80/67
85/72
75/62
80/67
85/72
75/62
80/67
85/72
75/62
80/67
85/72
75/62
80/67
85/72
75/62
80/67
85/72
75/62
60°F
C ooling
C apacity
55°F
D .B ./W.B .2
74,500
46,200
66,650
45,800
62,700
45,550
64,050
40,950
57,250
40,550
53,900
40,400
60,250
38,450
53,850
38,100
50,650
37,950
47,800
43,350
42,700
42,900
40,200
42,800
42,000
26,200
37,550
25,950
35,300
25,850
33,150
19,950
29,650
19,800
27,900
19,700
65°F
1 Below 55°F, unit requires a field installed low ambient control model CMA-28.
2 Return air temperature °F.
PA1360
PA1348
PA1342
PA1336
PA1330
PA1324
Model
72,600
45,450
64,850
44,950
60,900
44,850
62,100
39,950
55,450
39,550
52,050
39,500
58,300
37,600
52,100
37,250
48,900
37,150
46,150
40,550
41,200
40,150
38,700
40,100
40,450
25,550
36,100
25,300
33,900
25,250
31,950
19,500
28,500
19,300
26,750
19,250
70°F
Cooling Application Data — Outdoor Temperature 1
70,700
44,650
63,050
44,150
59,050
44,200
60,150
38,950
53,650
38,550
50,250
38,600
56,400
36,750
50,300
36,350
47,100
36,400
44,500
37,800
39,700
37,400
37,150
37,450
38,900
24,850
34,700
24,600
32,500
24,600
30,750
19,000
27,400
18,800
25,650
18,800
75°F
69,050
44,100
67,450
43,600
59,800
43,050
55,700
43,550
57,350
43,850
61,400
43,600
56,500
36,900
58,350
37,950
50,100
36,450
46,650
36,850
48,452
37,700
51,850
37,500
52,650
35,050
46,650
34,600
43,450
34,950
41,550
31,350
36,850
30,950
54,500
35,900
48,500
35,450
45,300
35,650
43,050
34,600
38,300
34,200
34,350
31,250
35,750
34,350
31,850
23,200
33,300
23,900
35,950
23,500
29,700
23,450
31,100
24,050
37,400
24,200
28,450
18,000
29,600
18,500
25,200
17,750
23,500
17,950
24,550
18,400
26,300
18,300
85°F
65,800
43,100
58,150
42,500
54,000
43,250
54,650
35,850
48,300
35,350
44,850
35,950
50,750
34,150
44,850
33,700
41,650
34,250
40,100
28,100
35,450
27,750
32,900
28,150
34,450
22,800
30,450
22,500
28,300
22,900
27,300
17,500
24,100
17,250
22,400
17,500
90°F
64,200
42,600
56,500
41,950
52,350
42,900
52,800
34,850
46,500
34,300
43,100
35,100
48,850
33,300
43,000
32,800
39,850
33,550
38,600
24,900
34,000
24,500
31,500
25,050
32,950
22,150
29,000
21,800
26,850
22,300
26,150
16,950
23,000
16,700
21,300
17,100
95°F
Outdoor Temperature°F
80°F
61,200
40,650
54,100
40,050
49,800
40,750
50,450
34,026
44,600
33,500
41,100
34,050
46,850
32,450
41,400
31,950
38,150
32,500
36,350
24,000
32,150
23,600
29,600
24,050
31,200
21,550
27,600
21,200
25,450
21,600
24,650
16,600
21,800
16,350
20,100
16,650
100°F
58,150
38,700
51,650
38,150
47,300
38,550
48,100
33,200
42,750
32,700
39,100
33,050
44,850
31,550
39,850
31,100
36,450
31,400
34,100
23,100
30,300
22,750
27,750
23,000
29,500
20,950
26,200
20,650
24,000
20,850
23,200
16,300
20,600
15,000
18,850
16,200
105°F
55,150
36,800
49,250
36,200
44,750
36,350
45,750
32,400
40,850
31,900
37,150
32,000
42,850
30,700
38,250
30,200
34,750
30,300
31,850
22,200
28,400
21,850
25,850
21,950
27,750
20,400
24,800
20,050
22,550
20,150
21,750
15,950
19,400
15,700
17,650
15,750
110°F
52,100
34,850
46,800
34,300
42,250
34,200
43,400
31,600
39,000
31,100
35,150
30,950
40,800
29,800
36,700
29,350
33,100
29,250
29,550
21,300
26,550
21,000
23,950
20,900
26,050
19,800
23,400
19,500
21,100
19,400
20,250
15,600
18,200
15,350
16,450
15,250
115°F
49,100
32,900
44,400
32,400
39,700
32,000
41,000
30,800
37,100
30,300
33,200
29,950
38,800
28,950
35,100
28,500
31,400
28,150
27,300
20,400
24,700
20,100
22,100
19,850
24,300
19,200
22,000
18,900
19,700
18,700
18,800
15,250
17,000
15,000
15,200
14,800
120°F
Form No.
Supersedes
Page
S3383-509
S3383-908
5 of 8
Building
Return Duct
Supply Duct
Supply and Return Ducts
Building
Blower Service
Access
Blower
and
Blower Motor
Heater Package
Heater Package
Access
Air Outlet
Air Inlet
Nearest Structure
24" min.
Control Panel
36" min.
Nearest Structure
Control Panel
Access
Airflow & Service Access Clearances
1 inch clearance
between duct and
any combustible
material if distance
between outside
wall and unit is less
than 3 feet (needed
on electric heat
units only).
The distance between
outside wall and unit
varies with installation
requirements.
Compressor
24" min.
Top
View
MIS-2143 A
Condenser fan
and motor access
from top.
Leave 60" min.
above fan.
Compressor
Access
Ground Level
1/4 inch per foot
slope away
from building
Mounting Slab
Package Unit
Side
View
Nearest Structure
Slab Mounting at Ground Level
Air Inlet
48" min.
48" min.
Metal frame
12" min. if in
32°F or lower climate
Poured concrete,
brick, or block
12" min. if in
32°F or lower climate
Elevated Mounting Platforms (Field Constructed)
Both legs must rest
on surface of platform
Both legs must rest
on surface of platform
Platform can be as
shown or solid
MIS-2144 A
Unit Dimensions
W
L
A
D
E
B
Compressor
access door
Control panel door
High voltage knockout
Low voltage knockout
Heater package knockout
Supply opening
C
Heater package access panel
Drain access
Return opening
F
Condenser fan
H
Condenser air
intake grille
Blower motor
access door
47 11/16"
G
Condenser air
intake grille
Unit Dimension Chart
Unit
PA/PH1324,1330,1336
PA/PH1342,1348,1360
Supply Size
A
C
5.875
32.875
9.875
37.875
Return Size
B
C
13.875
32.875
15.875
37.875
Unit Overall Dimensions
H (height) L (length) W (width)
26.25
53.25
38.125
33.25
55.25
42.375
D
23.25
30.25
Unit General Dimensions
E
F
G
1.125
1.375
35.625
1.5
2.375
38.125
MIS-2142 A
Optional Control Modules — Field Installed
Field Installed Part
Applicable To
Description
CMA-28
All Models
Low Ambient Control
CMC-15
All -A Models
Compressor Start Kit
Form No.
S3383-509
Supersedes S3383-908
Page
6 of 8
Optional Equipment — Roof Hood
• Shipped knocked down
• Polyester baked enamel galvanneal cabinet
• Heavy insulation - 1/2 inch
• Built-in filter
• Fresh air damper assembly provides up to 15% outside air.
• Requires prefabricated roof curb 9042-003 or 9042-004.
Order separately.
Model No.
Applicable To
RHP313-A
2, 2-1/2 and 3 ton models
Shipping Weight
110
RHP513-A
3-1/2, 4 and 5 ton models
120
† Equivalent units - Shipping
Performance and Application Data — RHP
RHP313-A Ventilation Air
Supply Air
Static
RHP513-A BFAD Ventilation Air
Supply Air
Static
Ventilation Air (CFM)
Ventilation Air (CFM)
0.00
N/A
N/A
133 183 226 260 283 290 304 320 370
0.00
N/A
N/A
80
165 215 250 280 310 340 370 400
0.20
N/A
N/A
133 183 226 260 283 290 304 N/A
N/A
0.20
N/A
N/A
80
165 215 250 280 310 340 370 400
0.40
N/A
N/A
133 183 2.26 260 283 290 N/A
N/A
0.40
N/A
N/A
80
165 215 250 280 310 340 370 400
N/A
Return Static 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50
Return Static 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50
D
38 1/4
X A WIDTH
AIR CONDITIONING UNIT
Unit Dimensions
ROOF HOOD
R oof H ood
Model
FILTER
C
RHP313-A
FRESH AIR
OPENING
RHP513-A
12 1/2"
Model
PA1324 / PH1324
PA1330 / PH1330
PA1336 / PH1336
PA1342 / PH1342
PA1348 / PH1348
PA1360 / PH1360
Nominal
A
Tonnage
2 Ton
2½ Ton
38-1/8
3 Ton
3½ Ton
4 Ton
42
5 Ton
C
D
26
53-1/4
33
55-1/4
1"
Filter
(1) 16 x 16
and
(1) 16 x 20
(2) 16 x 20
MIS-2254
Optional Equipment — Pre-Fabricated Roof Curb
• Heavy gauge galvanized with wood nailing strip.
• Prefabricated roof curb requires roof hood RHP313-A & RHP513-A.
Order separately.
RETURN AIR
SUPPLY AIR
1 1/2"
H
Model No.
Applicable To
9042-003
2, 2-1/2 and 3 ton models
E.U.†
.80
Shipping Weight
144
9042-004
3-1/2, 4 and 5 ton models
.80
160
† Equivalent units - Shipping
J
Heavy gauge galvanized with wood nailing strip, welded/leakproof one piece
construction - ready to install.
Used With
R oof H ood
Model
A
B
C1
D
E
F
J1
H1
Heat Pump and
Air Conditioning Units
9042-003
(P36 Curb)
RHP313-A
80-3/8
40-1/4
37-1/4
38-3/8
35-3/8
42
14-3/4
19-1/8
All 2, 2-1/2, & 3 Ton Models
9042-004
(P60 Curb)
RHP513-A
82-3/8
44-1/8
41-1/8
38-3/8
35-3/8
44
14-3/4
19-1/8
All 3-1/2, 4 & 5 Ton Models
Model
1 Duct Sizing Information:
Return air dimension “C” is length / Supply air dimension “C” is length.
Return air dimension “H” is width / Supply air dimension “J” is width.
Form No.
Supersedes
Page
S3383-509
S3383-908
7 of 8
Optional Equipment — Energy Recovery Ventilator
Model N o.
• Assures continuous supply of fresh air and reduction of all indoor air pollutants. IAQ ASHRAE 62.1
• Provides 250 to 400 CFM (adjustable) of outside air and exhaust. Efficiencies up to 77% heating and 65% cooling.
• Designed for easy installation on roof hoods RHP313-A and RHP513-A.
Shipping Weight
ERVR-A3D -X (230/208V)
125 lbs.
ERVR-C 3D -X (460)
125 lbs.
PERFORM ANCE AND APPLI CATI ON DATA - ERVR-A3C
Ambient
O.D.
DB/WB°F
105
HRS
HRL
75 19,080 12,960 6,120
VLT
V LS
V LL
12,020 8,164
HRT
3,855
70 12,960 12,960
0
8,164
8,164
65 12,960 12,960
0
8,164
8,164
80 28,080 10,800 17,280 17,690 6,804
75 19,080 10,800
100
8,280 12,020 6,804
85
HRS
HRL
VLT
V LS
V LL
HRT
HRS
HRL
9,921
6,739
3,182
11,925
8,100
3,825
7,751
5,265
2,486
0
10,530 10,530
0
6,739
6,739
0
8,100
8,100
0
5,265
5,265
0
0
10,530 10,530
0
6,739
6,739
0
8,100
8,100
0
5,265
5,265
10,886 22,815
V LL
8,775
8,985
17,550 6,750
10,800 11,407 4,387
0
7,019
6,727
9,921
5,616
4,305
11,925
6,750
5,175
7,751 4,387
113
8,921
8,775
146
5,709
5,616
93
6,862
6,750
112
4,460 4,387
73
65 10,800 10,800
0
6,804
6,804
0
8,775
8,775
0
5,616
5,616
0
6,750
6,750
0
4,387 4,387
0
0
6,804
6,804
0
8,775
8,775
0
5,616
5,616
0
6,750
6,750
0
4,387 4,387
12,247 22,815
7,020
8,640
19,440 17,690 5,443
75 19,080 8,640
10,440 12,020 5,443
70 10,980 8,640
5,216 15,502 8,775
14,040 14,601 5,616
6,804
15,795 14,601 4,492
10,108 17,550 5,400
12,150 11,407
3,363
0
3,510
7,897
6,577 15,502 7,020
8,482
9,921 4,492
5,428 11,925
5,400
6,525
7,751
3,510
4,241
2,340
6,917
5,443
1,474
8,921
7,020
1,901
5,709 4,492
1,216
6,862
5,400
1,462
4,460
3,510
950
0
65
8,640
8,640
0
5,443
5,443
0
7,020
7,020
0
4,492 4,492
0
5,400
5,400
0
3,510
3,510
60
8,640
8,640
0
5,443
5,443
0
7,020
7,020
0
4,492 4,492
0
5,400
5,400
0
3,510
3,510
0
80 28,080
6,480
21,600 17,690 4,082
13,608 22,815
5,265
13,500 11,407
2,632
8,774
75 19,080 6,480
12,600 12,020 4,082
70 10,980 6,480
17,550 14,601 3,369
11,232 17,550 4,050
7,938 15,502 5,265
10,237
9,921
3,369
6,552 11,925 4,050
7,875
7,751
2,632
5,118
4,500
6,917 4,082
2,835
8,921
5,265
3,656
5,709
3,369
2,340
6,862 4,050
2,812
4,460
2,632
1,828
0
65
6,480
6,480
0
4,082 4,082
0
5,265
5,265
0
3,369
3,369
0
4,050 4,050
0
2,632
2,632
60
6,480
6,480
0
4,082 4,082
0
5,265
5,265
0
3,369
3,369
0
4,050 4,050
0
2,632
2,632
0
3,510
14,850 11,407
1,755
9,652
80 28,080 4,320
23,760 17,690
2,721 14,968 22,815
75 19,080 4,320
14,760 12,020
70 10,980 4,320
19,305 14,601 2,246
12,355 17,550 2,700
2,721
9,298 15,502 3,510
11,992
9,921
2,246
7,675 11,925
2,700
9,225
7,751
1,755
5,996
6,660
6,917
2,721
4,195
8,921
3,510
5,411
5,709
2,246
3,463
6,862
2,700
4,162
4,460
1,755
2,705
65
4,320 4,320
0
2,721
2,721
0
3,510
3,510
0
2,246
2,246
0
2,700
2,700
0
1,755
1,755
0
60
4,320 4,320
0
2,721
2,721
0
3,510
3,510
0
2,246
2,246
0
2,700
2,700
0
1,755
1,755
0
1,755
13,747
9,921
1,123
8,798
11,925
1,350
10,575
7,751
877
6,873
70 10,980 2,160
8,820
6,917
1,360
5,556
8,921
1,755
7,166
5,709
1,123
4,586
6,862
1,350
5,512
4,460
877
3,583
65
3,780
2,160
1,620
2,381
1,360
1,020
3,071
1,755
1,316
1,965
1,123
842
2,362
1,350
1,012
1,535
877
658
60
2,160
2,160
0
1,360
1,360
0
1,755
1,755
0
1,123
1,123
0
1,350
1,350
0
877
877
0
0
10,980
6,917
0
6,917
8,921
0
8,921
5,709
0
5,709
6,862
0
6,862 4,460
0
4,460
70 10,980
75
V LS
6,917
75 19,080 2,160
80
HRT
15,502 10,530 4,972
180
60 10,800 10,800
90
VLT
VENTILATION RATE - 250 CFM
65% Efficiency
70 10,980 10,800
80 28,080
95
Summer Cooling Performance
(Indoor Design Conditions 75° DB/62° WB)
VENTILATION RATE - 325 CFM
64% Efficiency
VENTILATION RATE - 400 CFM
63% Efficiency
16,920 12,020
1,360
10,659 15,502
65
3,780
0
3,780
2,381
0
2,381
3,071
0
3,071
1,965
0
1,965
2,362
0
2,362
1,535
0
1,535
60
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Legend:
VLT = Ventilation Load - Total
VLS = Ventilation Load - Sensible
VLL = Ventilation Load - Latent
VENTILATION RATE
Ambient
O.D. 400 CFM 75% Efficiency 325 CFM 76% Efficiency 250 CFM 77% Efficiency HRT = Heat Recovery - Total
HRS = Heat Recovery - Sensible
HRL = Heat Recovery - Latent
WVL
WHR
WVL
WHR
WVL
WHR
DB°F
WVL = Winter Ventilation Load
65
2,160
1,620
1,755
1,333
1,350
1,039
WHR = Winter Heat Recovery
PACKAGE UNIT
Winter Heating Performance
(Indoor Design Conditions 70°F DB)
60
4,320
3,240
3,510
2,667
2,700
2,079
55
6,480
4,860
5,265
4,001
4,050
3,118
50
8,640
6,480
7,020
5,335
5,400
4,158
8,100
8,775
6,669
6,750
5,197
45
10,800
40
12,960
35
15,120
11,340
30
17,280
12,960
14,040
10,670
10,800
8,316
25
19,440
14,580
15,795
12,004
12,150
9,355
20
21,600
16,200
17,550
13,338
13,500
10,395
15
23,760
17,820
19,305
14,671
14,850
11,434
9,720
10,530
8,002
8,100
6,237
12,285
9,336
9,450
7,276
ROOF HOOD
ROOF CURB
ROOF
MIS-2253
RETURN DUCT
SUPPLY DUCT
UNI T DI M ENSI ONS
Model
Width
Depth
Height
Shipping Weight
ERVR
* 32-3/4
18-3/4
18-3/4
125 lbs.
* Does not include 1" mounting brackets on each side of ERVR.
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
www.bardhvac.com
Due to our continuous product improvement
policy, all specifications subject to change
without notice.
Before purchasing this appliance, read important energy
cost and efficiency information available from your retailer.
Form No.
S3383-509
Supersedes S3383-908
Page
8 of 8
Form No.
S3383
May, 2009
Supersedes: S3383-908