DeweCatalog 2012

DeweCatalog 2012
Dewetron USA
Product Selection Guide
State of the Art Data Acquisition
Instruments for applications in:
automotive - Aerospace - energy industrial - process monitoring
w w w . D E W A-MR&D
ERICA.COM
w w w. d e w e t r o n . c o m
Dewetron worldwide HQ in Graz, Austria
Dewetron American HQ in Wakefield, RI USA
Dewetron sales office in Laguna Hills, CA USA
Dewetron automotive center in Livonia, MI USA
DISCLAIMER
AccrediTations
The information contained in this document is subject to
change without notice. Accordingly, no guarantee is made as
to the accuracy of any information contained herein.
CAL LAB: NIST traceable, ANSI Z540 compliant
Details available at www.dewamerica.com/Support
NOTICES
MIL-STD-810F shock and vibration:
- Vibration: 514.5 procedure 1
- Shock: 514.5 procedure X
This document contains information which is protected by
copyright. All rights are reserved. Reproduction, adaptation,
or translation without prior written permission is prohibited,
except as allowed under the copyright laws. All contents ©
1998-2012 Dewetron, Inc.
Dewetron is a trademark of Dewetron Ges.m.b.H.
DEWETRON products are tested to conform to:
All portable products:
EN STANDARD shock and vibration:
- Vibration: EN 600068-2-6
- Vibration, random: EN60721-3-2 Class 2M2
- Shock: EN 60068-2-27
SideHAND is a trademark of Dewetron, Inc.
All trademarks and registered trademarks are acknowledged
to be the property of their owners.
10 9 8 7 6 5 4 3 2 1
Version 4.0.0
June 2012
Printed in USA
2
Dewetron PRODUCT SELECTION GUIDE
Certifications
ISO-9001 Dewetron Ges.m.b.H.
ISO-14001 Dewetron Ges.m.b.H.
CE Mark
Product Selection Guide
OVERVIEW
D300 / D3PC
What makes a DEWETRON...?
System architecture
DS-7 SOFTWARE
ECONOMICAL instrument...
choice of signal conditioners
WIDE RANGE DC POWER
made in USA
4
DEWE-3040-RM
RACK-MOUNTING with display...
19” rack compatible
huge 19” wide screen
made in USA
12
DEWE-214
ULTIMATE PORTABLE...
DC powered, FLEXIBLE
TOP NOTCH conditioners
battery option
50
40
interfaces
interfaces...
IRIG / GPS time code
CAN, Flexray, XCP, OBDII
ARINC, 1553, PCM
NTSC/PAL VIDEO
70
SENSORS
proven sensors
current sensors
accelerometers
speed sensors
thermocouples
cameras
DEWE-3210
PortablE instrument...
choice of signal conditioners
battery powered
made in USA
22
CONDITIONERS
ideal front-end...
isolated / differential
conditioners
every sensor, signal
56
ACCESSORIES
great add-ons...
mobile displays
shipping cases
chargers and batteries
Carrying bags
72
82
DEWE-3050
BENCHTOP instrument...
more channels than any other
all-in-one
battery/AC powered
made in USA
30
A/D CARDS
top A/D technology
16, 22, and 24-bit
simultanous sampling
digital inputs
counters
66
DATALOGGERS
small LOGGER...
voltage and temperature
inputs
low and high sample rates
86
Dewetron PRODUCT SELECTION GUIDE
3
What Makes a Dewetron...
...a Dewetron?
There are several things, but far and away the
most important thing is the ability of our data
acquisition systems to display, acquire, and replay
ASYNCHRONOUS MULTI-DOMAIN DATA. That’s a
mouthful - but what does it really mean?
Multi-domain Measurements...
Consider testing a car or truck. You will want to hook up some
sensors of your own, such as accelerometers, thermocouples,
RPM, etc. In addition, it is very handy to be able to tap into the
vehicle CAN BUS and grab one or a hundred parameters, like
wheel speeds, steering wheel position, pedal positions, coolant
temperature, etc.
So immediately we have ANALOG sensor data + CAN BUS digital
data + GPS serial data + VIDEO frames... all of these data types
exist in different domains, and they come into our system at their
own rates, i.e., asynchronously. Dewetron systems can easily
handle asynchronous multi-domain data input from these sources
AND MORE!
In the aerospace world there are additional interfaces, such as
ARINC 429, 1553, and PCM data, as well as GPS and IRIG time
code. We offer all of these interfaces, and more, for most of our
systems. More interfaces are being added all the time.
Rugged, field-worthy design
Another important Dewetron distinction is our MIL-STD and EN
STD MECHANICAL DESIGNS, which provide excellent shock
and vibration specifications. Rugged designs allow your Dewetron
system to go just about anywhere, and get the job done. We offer
solid state hard drives for our systems, which provide enhanced
reliability in harsh shock and vibration environments.
SCALABLE..
A third Dewetron hallmark is SCALABILITY - the ability to scale
up from a few channels to many, and to distribute these channels
in several locations. This is critical in both portable and fixed
installation applications alike.Consider a large scale testing
facility, instrumenting a large aircraft with hundreds of dynamic
sensors (such as accelerometers) and perhaps thousands of static
measurements.
POWERFUL Software...
Award-winning DS-7 data acquisition SOFTWARE provides the
interface to all your Dewetron hardware, the interfaces, signal
conditioners, A/D cards ... and allows you an unprecedented level
of control over how the screens are set up, and how they look.
EASY TO USE...
Engineers and technicians appreciate the ease of use and short
learning curve that DS-7 provides, and have come to rely on it for
demanding data acquisition applications, all over the world.
4
Dewetron PRODUCT SELECTION GUIDE
P u t i t a l l t o g e t h e r, a n d
you have a Dewetron
data acquisition system
– available from just
a handful of channels,
to dozens, hundreds,
or even thousands.
Dewetron: multi-domain,
tough, scalable, yet easy
to use!
DEWETRON Applications:
Only from Dewetron...
◙◙
Record every kind of analog sensor that is in use
today: strain, pressure, vibration, temperature, force,
voltages, currents, displacement, distances, and
more
◙◙
Also record GPS parameters such as
latitude, longitude, speed, distance, etc in
mobile applications
◙◙
Sync your measurements to absolute time
via IRIG or GPS
◙◙
Add more interfaces to your Dewetron
system, such as VIDEO, PCM data from
spacecraft and missiles, MIL-STD-1553
and ARINC 429 from aircraft, CAN BUS
from vehicles and engines, and many
more
In this product selection guide you will find nice overview of our
most important products, starting with portable systems.
Dewetron portable instruments are available in several popular
models, all battery powered and fully capable despite their small
size.
Next come our benchtop instruments, which are typically larger
than the portable models, and yet more expandable as a result.
Then we present our front-end instruments, which do not have
a computer or display of their own - you connect them to your own
computer using USB or ethernet, depending on the model.
Then come rack-mounting instruments: we offer 19” rack
compatible instruments both with and without a built-in display.
This leads us to our large-scale instruments - which are meant
to start small but scale “up” into the hundreds or even thousands
of dynamic and static channels.
Aerospace
Automotive
Transportation
Manufacturing
Research & Development
Energy & Power
Anywhere that data
acquisition is found!
Then we present our application specific instruments. These
are Dewetron “all in one” instruments which have been geared to
address specific applications, such as ENERGY TEST. Several
more models apply Dewetron technology and innovation to other
applications, such as the classic SCOPE, and more.
Next come signal conditioners, a complete range of single and
multi-channel signal conditioning modules for both fast and slow
signals.
Our top-notch A/D cards follow. These are mission critical!
Then our interfaces, such as ARINC, IRIG, GPS, 1553, PCM...
Then sensors, including our own video cameras, and more.
Finally we present our accessories, such as MOBILE displays,
and accessories related to the power system of your Dewetron
system, especially battery-powered models, which require
batteries and related accessories.
Battery power
provides
unprecedented
flexibility in terms
of how and where
you can work!
Dewetron PRODUCT SELECTION GUIDE
5
Software Ties it All Together...
Within every Dewetron system is our
award-winning data acquisition software
package, DS-7 Steadily improved since
2000, DS-7 provides complete control
over all of the hardware interfaces within
the system.
Fast Channel Setup & Scaling
Fast, easy and accurate configuration is the goal, so
we’ve included advanced features like an XML sensor
database that you can populate with all your sensors
– then just pick them from the list on a given channel’s
setup screen. Also COPY and PASTE channel
configurations, and grouping for functions such as
ZERO and high/low calibration. Even auto-ranging
and display scaling are built-in.
DS-7 key features:
◙◙
Software basis of every DEWETRON system
◙◙
Records analog + digital + VIDEO + CAN + ARINC + 1553 +
PCM...and other kinds of data
◙◙
SYNCHRONOUS MULTI-DOMAIN measurements!
◙◙
No license required to review/replay/export data - install on any PC
◙◙
Easy setup and configuration - save unlimited numbers of setups
◙◙
“Open” data format (version 7.0 and higher)
◙◙
Extensible via COM/DCOM software plugins - write your own, or
hire Dewetron to create what you need
Below, the setup dialog from one of our DAQP-STG
signal conditioners. Starting from the top-right, you set
the actual hardware settings of the module, including
measurement mode (bridge, voltage, resistance, etc.),
sensitivity, filtering, bridge completion, excitation, etc.
Then moving to the left, you can enter in the channel
name, description, and engineering units. In this
section you may also set a sample rate divider for this
channel, so that although it is sampled at the selected
dynamic rate, it does not have to be written at that
rate.
In the bottom left section you can perform linear
scaling in one of several convenient ways. You can
even perform end-to-end scaling incorporating the
output of your sensor. That’s what the “from average”
and “from RMS’ buttons are for: DS-7 will calculate
the slope based on the actual output of your static or
dynamic sensors.
The bottom-right section is a handy reference, a bar
graph scaled on the left side with the actual voltage
coming in, and on the right side, with the scaled value.
The buttons for Average, AC RMS, and Min/Max
control which calculated values of the channel are
displayed in the bar graph.
6
Dewetron PRODUCT SELECTION GUIDE
Main setup screens
In the picture above, you can see the main analog setup screen, where you
can turn on/off channels, select any particular channel for setup as shown in
the previous section, copy and paste channel settings, and more.
Just press the Used/Unused buttons on the left side to turn on/off channels,
in whatever combination you like. The top of the column has a button for turn
ing all channels on/off at once.
Notice the other buttons, which reveal setup screens for other input types
and functions:
Standard input types include analog, digital, counter, video, GPS, and Math.
But you can add other input types, such as CAN BUS, PCM, ARINC 429,
1553, PCM data, and many more. All channels are recorded synchronously,
time stamped against the high resolution clock within the ORION A/D card
(which can be synched to IRIG or GPS absolute time if required).
Virtual channels - before and/or after recording
Create whatever channels you need from the real channels, using algebra, trig, math, logic, and programmable filtering (IIR, FIR,
FFT), integration (INT), DINT, DER, DDER, and much more. Starting with v7.0 you can add virtual channels AFTER recording as well.
Nothing can touch the flexibility and sheer power – while still being easy to learn – of DS-7.
There are built-in MATH functions such as BASIC STATISTICS which calculate popular functions automatically, such as RMS, average,
MIN, MAX, STD DEC, and many more. Just checkmark the channels you want to process, and which outputs you would like from each
channel. You can also set the rate at which these statistics are calculated and stored.
Above: main MATH channel screen Right: BASIC STATS setup dialog
Digital Filtering
You can create one or many filters, and process channels
through any or all of them. There are FIR, IIR, and FFT type
filters. The IIR setup also includes programmable integration,
double integration, derivation, double derivation, and polynomic
processing with multi-sectional coefficients.
The FIR filter type has the advantage of NO PHASE SHIFT! This
is possible only in the digital domain, of course, because every
real analog filter imposes a delay, or phase shift.
The FFT filter math function provides the power of our spectral
analyzer, and a great selection of windowing types, like
Hamming, Hanning, Blackman, and more.
And as mentioned, if what you want to do is too intensive for
the CPU in real time, you can set up and execute all of these
functions AFTER recording, where the CPU can handle anything
that you can dream up for it to do.
IIR FILTER setup dialog
Advanced options
The DSA version of DS-7 includes advanced features for
dynamic signal analysis, including order tracking, rotational and
torsional vibration, SRS, Sine Processing, Frequency Response
Function, Human Vibration Analysis, and more. It also adds some
additional display outputs, such as Orbit, Waterfall, and 1/3rd
Octave Analysis.
You can also order these options individually, if you just need
something like Blade Balancing, or Order Tracking with waterfall
displays, for example.
Dewetron PRODUCT SELECTION GUIDE
7
Flexible and Easy Display Setup
Not just easy, but amazingly powerful and
flexible. Put any graphical display object - strip
charts, scopes, meters, 3D graphs, tabular lists,
alarm lights, FFT’s and XY plots - anywhere
on the screen, and assign any channel(s) into
them.
Then save everything to a convenient setup file
which contains both the channel setup/scaling
AND the displays.
Already recorded your data? No problem; you
can change the display design of any existing
data file, and then save it into the data file.
Or apply a common screen design layout to a
large number of files all at once!
Screen Name Setup Mode
Click the SCREEN NAME icon and you can
rename, reorder, add or delete screens and
their icons as they are shown across the main
toolbar!
Screen name setup
DESIGN MODE
Show channel from selected widget
Property setup mode
Show channels as a list
Hide/show this panel
Show channels in groups
Hide/show panel
Screen Design Mode
Click the DESIGN button and you are immediately shown a strip of icons which contain the display “widgets”
that you can put onto any screen:
Design the screens of your dreams, simply by dragging the widgets around, sizing them, and assigning any active channels into them
The screen design of DS-7 has won awards all around the world due to its brilliance. Once you try it, you will never want to work any
other way. Just click any widget and its properties will be shown on the left design panel. Click and change whatever you want. You can
drag channels right off the channel list on the right side of the display, or click a widget first and then click one or more channels from
the list to assign them into it.
8
Dewetron PRODUCT SELECTION GUIDE
Choice of Recording modes
The default mode is ALWAYS FAST, meaning that you simply
press STORE and the system records your data at the selected
sample rate.
Or select FAST ON TRIGGER mode, and then set up one or
more trigger conditions, with pre and post-trigger time. DS-7
offers a wide range of trigger logic selections, including triggering
from the actual signal, the RMS or AVE value of the signal...
triggering from a live FFT of the signal, from absolute or relative
time, and more.
REDUCED storage still samples at the selected dynamic rate, but
writes to disk at a lower rate that you can control. So you still get
the amplitude resolution without the big file.
But perhaps the most interesting is a combined mode called
FAST ON TRIGGER, SLOW OTHERWISE, where data
BETWEEN the triggers is stored at the reduced rate! This is a
kind of “dual speed mode” that provides you full speed data when
you want it, and reduced data when you don’t.
Annotating Recordings
During acquisition you can press the space bar and add simple
events to the datafile. Or press the N key and type a message.
A third way is to connect a simple PC microphone and record a
voice annotation. All events are time-stamped and added to the
datafile.
All of these markers are shown during replay, and you can search
for them by double-clicking them inside the log. It couldn’t be
easier. You can even add more markers after recording, to further
annotate the data file.
You can also define a DATA HEADER screen that will pop up
when you record data, where your operators can enter some
whatever information you want them to.
All of data header responses are captured into the data file, and
can br printed and displayed after recording, so you can create a
perfect record which is highly self-documented.
Click and Zoom
In the replay mode, you can click and drag the cursors into
position around an area of interest, then simply click between
them to zoom the area of interest to the width of the graph. It is
really that simple.
To zoom back out, just right-click
on the graph... or use the blue [-]
button at the bottom right corner
of the graph.
If your system has a touchscreen you zoom in with one finger!
Below, when you open a file, the whole thing is showed. With one finger (or the
mouse), drag the cursors across the area of interest, as shown here:
Above: Now just touch (or click) once between the cursors, and that area will be
zoomed to the entire width of the recorder window!
Right: Notice how the selected area is shown at the top in the reference bar. This
small highlighted window can also be dragged with your finger or mouse.
Dewetron PRODUCT SELECTION GUIDE
9
Easy EXPORT to a wide range of
formats
Once you get your data into DS-7, you need
to get it out, and we’ve provided numerous
standard export formats that you can translate
your data to. You can even have DS-7
automatically convert data files as soon as you
press STOP if you like.
Print-outs on multiple pages
Make the screen look just the way you want,
and then press the PRINT button. Choose from
portrait or landscape modes, and type some
additional text into the title bar if you like. Link
your company logo and it will appear on the
print-outs automatically.
Want to emulate those obsolete paper
recorders without the expensive thermal paper?
Click the box called MULTIPLE PAGE printout
and then choose how much time you want to
print on each page. Uses any WIndows printer,
even in full color.
Above: get your data to look the way that you like it (including zooming,
adding meters, scopes, etc - and then click the PRINT screen...
Above: You get a print preview. From here you can turn on or off a header with your
logo and other info to print, additional comments, or select the MULTI-PAGE option.
Math analysis after recording
As mentioned, with DS-7 comes the ability to run all of the math
functions during or after recording, so you can create filters
and dozens of other advanced functions and cross-channel
calculations after recording and DS-7 will calculate and generate
them upon demand.
The original “raw” channels are never affected in any way - new
virtual channels are simply created.
10
Dewetron PRODUCT SELECTION GUIDE
In addition to a powerful FORMULA editor, where you can create
just about any function, there are dedicated MATH function
groups for FILTERING, SPECTRAL ANALYSIS, REFERENCE
COMPARISONS, ARRAY PROCESSING, STATISTICS, and more.
In DS-7 you can also re-scale data after recording, in case an
error was made during set-up. Great data in; great data out. Easy
seup. Incredible recordings.That’s the power of DS-7.
System Architecture Overview
At the center of most Dewetron systems is one of our A/D
cards. Not only does this card provide high resolution digitizing
of the analog signals, but it serves the vital role of providing
a high speed master CLOCK for synchronizing the incoming
data from PCM, ARINC, 1553, video cameras, CAN bus data,
and more. So whether you are testing cars, airplanes, factory
machines, spacecraft, trains, all of the data are recorded synchronously all the time, every time.
Databus interfaces
PCM, ARINC 429, 1553
Various sensors connected via ETHERNET inteface(s)
EPAD modules - connected via SERIAL inteface(s)
VIDEO input
NTSC or camera
DEWE-A/D
Digital
input
Digital
output
PC
DEWE Modules
All analog sensors:
STRAIN GAGES
ACCELEROMETERS
MICROPHONES
VOLTAGE
CURRENT
RTDs and T/C’s
LOAD CELLS
and more
Signal
conditioning
Sensor
supply
Rugged PC
Analog
input
DS-7
CAN BUS
interfaces
OPTIONS
OPT-PCM, etc.
Counter
input
Tach pulse
[
]
SYNC from another
Dewetron system
GPS UTC time/speed Source
or IRIG time code interface
upper: DEWE-IRIG-CLOCK
lower: DEWE-GPS-CLOCK
ext.
clock
int.
clock
Note - either can be installed inside the
Dewetron chassis, or remain external boxes
as shown here
Dewetron PRODUCT SELECTION GUIDE
11
D300-16 with MDAQ conditioners
D300 series
www.dewamerica.com/Products/D300
OVERVIEW
The D300 is our most affordable and flexible data
acquisition and computing platform. It can be
configured in several basic ways:
◙◙ As an 8-channel noise and vibration analyzer
(ORION-0824-200 A/D card inside): D3PC-8
◙◙ As a 4-channel noise and vibration analyzer
(ORION-0424-200 inside): D3PC-4
◙◙
With up to 16 ISOLATED SC4 series basic signal conditioners,
in blocks of four channels (any four can be installed), and any
A/D card inside
◙◙
With up to 16 MDAQ DIFFERENTIAL signal conditioning
channels, any two MDAQ-SUB blocks of 8 channels, and any
A/D card inside
◙◙
With any ZTEC series SCOPE card, as 2-channel PC-based
scope
◙◙
With any ARINC or 1553 interface card, as a highly portable
aircraft BUS recorder/analyzer
There are many additional instruments that can be
built on the D300 platform - it’s just that flexible. And
we have done everything to make it as affordable as
possible without sacrificing quality or reliability.
12
Dewetron PRODUCT SELECTION GUIDE
◙◙ Highly configurable and economical system
◙◙ Choose from direct inputs, SC4 isolated
conditioners, or any two MDAQ-SUB series
signal conditioners
◙◙ Full power DEWE computer inside
◙◙ One half-length PCI slot inside
◙◙ Compatible with ORION and AD series A/D
cards
◙◙ 500 GB removable HDD
◙◙ Keyboard and mouse are included
◙◙ VGA output connector (supports XGA
resolution displays)
◙◙ Wide range DC power input, plus a
convenient AC/DC adapter is included
◙◙ Metal door protects the computer interfaces
(ethernet, USB, VGA, A/V, etc.)
◙◙ Ruggedized construction, MIL-STD, CE
MARK, and more
◙◙ Small footprint D3PC available also as a
pure computer or PCI bridge host platform
◙◙ Made in USA
◙◙ Full year warranty
MDAQ differential conditioners
The D300 model is compatible with our MDAQ
differential conditioners. You may choose any two of
the MDAQ-SUB 8-channel conditioners to be installed
on the front panel, with BNC or DSUB connectors.
The most popular MDAQ-SUB is the STG-D, which
is a strain/bridge universal type signal conditioner,
because in addition to handling any kind of strain
gage and low voltage by itself, it also accepts our MSI
multiple sensor adapters, which convert each input
to something different, such as IEPE accelerometers,
charge accelerometers, ±200V signals, RTDs, and
even high bandwidth thermocouples.
But there are other MDAQ-SUBs, including 8 channel
IEPE accelerometers, 8 channels of voltage from ±125
mV to ±200V, and more.
SC4 ISOLATED signal conditionERS
When configured for SC4 conditioners, you can pick
any four of our ISOLATED 4-channel conditioners,
for a total of 16 inputs.
There are SC4 conditioners for different voltage
levels, different strain gage conditioners in full or half
bridge, with various thermocouples, and more.
EPAD2 series conditioners can be added to either
version, allowing you to expand your D300 to more
channels, adding slow channels for temperature, as
well as DC voltages and currents, in blocks of eight
channels.
D300 with SC4 signal conditioner panels: 4 thermocouples, four full or half bridge
strain gage, and four voltage inputs. All are isolated to 1500Vrms.
D3PC-4 and D3PC-8 models
The smallest DEWETRON systems ever made are
these two:
The D3PC-4 features four IEPE/low-voltage inputs
and an advanced counter input.
The D3PC-8 features eight IEPE/low-voltage inputs,
two advanced counter inputs, 8 DIO lines ... and
you can expand this model to have two CAN BUS
interfaces and more digital inputs/counters. You can
also sync multiple systems together to make a larger
channel count system!
Dewetron PRODUCT SELECTION GUIDE
13
D3PC-4 and D3PC-8 models
There are several basic configurations of the D300, starting with direct inputs from the A/D card, or ISOLATED
SC4 modules, or DIFFERENTAL MDAQ conditioners...
DIRECT INPUTS FROM ORION CARDS, 4-channel instrument
D3PC-4
◙◙
4 x BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support
◙◙
24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, anti-aliasing filters
◙◙
4 different input ranges: ±0.1, ±0.5, ±2, ±10 V
◙◙
Single-ended or differential configuration, AC (0.15 or 3.4 Hz) or DC coupled
◙◙
SUB-D-9 connector with 1 synchronous advanced counter / encoder with
programmable threshold levels (0 ~ 40 V), input voltage range -35 ~ 60 V, AC/DC
coupling, plus an external trigger input (TTL with pull-up)
◙◙
Includes DS-7-SE acquisition and analysis software
◙◙
Nothing needs to be added to complete this system (except a display)
D3PC-4 upgrades
RAM-2048-3072
HARD DISK upgrades
Software upgrades
CAL-ORION-04-NIST-4
USB-ARINC or -1553
Upgrade the PC RAM from 1
GB to 2 GB or 3 GB
Change the HDD from a 500
GB spinning disk to a solid
state drive: 32, 64, or 128 GB.
Also, get a spare HDD
Upgrade the basic version of
DS-7 from -SE to -PROF, or
-DSA.
NIST traceable calibration data
for the ORION-0424-200 card
within the D300-4
Add a USB interface for ARINC
429 or MIL-STD-1553 interfaces to your system. Requires
software option PLUGINARINC/1553
D3PC-4 options & accessories
MOB-DISP-17
0424-CBL-DIG
Software options
ACCELS
GPS sensor
VIDEO camera
Ruggedized mobile display with
capacitive touchscreen, 17”
diag, XGA resolution
Mating cable for the digital
input connector of the ORION0424-200 card, 2 meters, with
stripped and tinned leads.
Add software options like order
tracking, sound level meter,
modal analysis, balancing,
and more.
Dewetron offers DYTRAN IEPE
accelerometers, which are perfectly suited to the D3PC-4
You can add a simple USB
GPS sensor with 1 Hz update
rate, or one of our 20/100 Hz
GPS sensors for incredible
precision.
A common webcam can be connected to the USB port, allowing you to record video in sync
with your data
D3PC-4 and -D3PC8 typical applications
BRAKE NOISE testing
HUMAN VIBRATION testing
MODAL testing
GENERAL PURPOSE testing
The four inputs can be used with IEPE microphones to measure SOUND very accurately.
Add a GPS sensor to correlate the data with
vehicle speed, position, heading, and other
parameters.
Add seat and other accelerometers with the
HUMAN VIBE software option, to study the
effects of vibration on human subjects. Ideal
for machinery, vehicles, and other applications.
With the synchronous counter input and four
IEPE inputs, the D3PC-4 makes the perfect
small channel count modal analysis instrument. Just add DS-OPT-FRF software option
and some IEPE accelerometers.
Any basic data acquisition application where
you need a small footprint self contained data
acquisition instrument with great dynamic
specifications (24-bit, 200 kS/s/ch, anti-aliasing)... at a great price point!
14
Dewetron PRODUCT SELECTION GUIDE
DIRECT INPUTS FROM ORION CARDS, 8-channel instrument
D3PC-8
D3PC-8 upgrades
◙◙
8 analog voltage or ICP (4 / 8 mA) inputs with sensor cable break detection and
TEDS support
◙◙
24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, anti-aliasing filters
◙◙
4 different input ranges: ±0.1, ±0.5, ±2, ±10 V
◙◙
Single-ended or differential configuration, AC or DC coupled
◙◙
8 synchronous TTL digital I/Os (upgradable to 25V protection via UP-ORION-CTR8)
◙◙
2 synchronous advanced counter / encoder or 8 digital inputs with programmable
threshold levels (0 ~ 40 V), input voltage range -35 to 60 V, AC/DC coupling
◙◙
Includes DS-7-SE acquisition and analysis software
◙◙
Nothing needs to be added to complete this system (except a display)
RAM-2048-3072
HARD DISK upgrades
UP-ORION-CAN2
UP-ORION-CTR8
UP-ORION-200-1000-8
USB-ARINC or -1553
Upgrade the PC RAM from 1
GB to 2 GB or 3 GB
Change the HDD from a 500
GB spinning disk to a solid
state drive: 32, 64, or 128 GB.
Also, get a spare HDD
Adds two synchronous highspeed CAN BUS interfaces,
including DS-OPT-CAN software option, 2 x DB9’s
Upgrade from 8 TTL I/O lines
to 25V protected lines, and
from 2 advanced counters, to 8
advanced counters
Upgrade the A/D card from 200
kS/s max to 1000 kS/s max (@
16-bit instead of 24-bit)
Add a USB interface for ARINC
429 or MIL-STD-1553 interfaces to your system. Requires
software option PLUGINARINC/1553
D3PC-8 options & accessories
MOB-DISP-17
CTR-CBL-05
Software options
ACCELS
GPS sensor
VIDEO camera
Ruggedized mobile display with
capacitive touchscreen, 17”
diag, XGA resolution
Connection cable from counter
input (FGG.1B.307) to open
end, length 5 m.
Add software options like order
tracking, sound level meter,
modal analysis, balancing,
and more.
Dewetron offers DYTRAN IEPE
accelerometers, which are perfectly suited to the D3PC-4
You can add a simple USB
GPS sensor with 1 Hz update
rate, or one of our 20/100 Hz
GPS sensors for incredible
precision.
A common webcam can be connected to the USB port, allowing you to record video in sync
with your data
SOUND analysis testing
MODAL testing
Eight high-dynamic microphone inputs with
anti-aliasing filtering makes the D300-8 ideal
for all kinds of sound analyses. Great for
working in an anechoic chamber or in the
field.Add the DS-OPT-SNDLVL software option
and IEPE microphones.
With the synchronous counter input and eight
IEPE inputs, the D300-8 makes the perfect
medium channel count modal analysis instrument. Just add DS-OPT-FRF software option
and some IEPE accelerometers.
Dewetron PRODUCT SELECTION GUIDE
15
D300-8 with SC4/MDAQ conditioners
The D300-8 is compatible with 8 channels of ISOLATED SC4 modules, or 16 channels of DIFFERENTIAL
MDAQ conditioners...
WITH MDAQ DIFFERENTIAL or SC4 ISOLATED SIGNAL CONDITIONERS
D300-8
◙◙
8 channel ORION-0824-200 PCI A/D card built-in
◙◙
24-bit resolution, simultaneous sampling, 200 kS/s per channel 8 synchronous TTL
digital I/Os
◙◙
2 synchronous TTL counter / encoder or 8 TTL digital inputs
◙◙
Includes DS-7-SE acquisition and analysis software
◙◙
Please add any 2.0U-PANEL-MDAQ (or 1.5U-PANEL-MDAQ) plus 2 x MDAQ-SUBs
OR please add 16 channels of SC4 series signal conditioners
(MDAQ and SC4 series conditioners cannot be mixed)
D300-8 upgrades
RAM-2048-3072
HARD DISK upgrades
Software upgrades
USB-ARINC or -1553
Upgrade the PC RAM from 1
GB to 2 GB or 3 GB
Change the HDD from a 500
GB spinning disk to a solid
state drive: 32, 64, or 128 GB.
Also, get a spare HDD
Upgrade the basic version of
DS-7 from -SE to -PROF, or
-DSA.
Add a USB interface for ARINC
429 or MIL-STD-1553 interfaces to your system. Requires
software option PLUGINARINC/1553
A/D card upgrades
UP-ORION-200-1000-8
UP-ORION-CAN2
UP-ORION-CTR8
Upgrade the A/D card from 200
kS/s max to 1000 kS/s max (@
16-bit instead of 24-bit)
Adds two synchronous highspeed CAN BUS interfaces,
including DS-OPT-CAN software option, 2 x DB9’s
Upgrade from 8 TTL I/O lines
to 25V protected lines, and
from 2 advanced counters, to 8
advanced counters
D300-8 options & accessories
MOB-DISP-17
CTR-CBL-05
Software options
ACCELS
GPS sensor
VIDEO camera
Ruggedized mobile display with
capacitive touchscreen, 17”
diag, XGA resolution
Connection cable from counter
input (FGG.1B.307) to open
end, length 5 m.
Add software options like order
tracking, sound level meter,
modal analysis, balancing,
and more.
Dewetron offers DYTRAN IEPE
accelerometers, which are perfectly suited to the D3PC-4
You can add a simple USB
GPS sensor with 1 Hz update
rate, or one of our 20/100 Hz
GPS sensors for incredible
precision.
A common webcam can be connected to the USB port, allowing you to record video in sync
with your data
16
Dewetron PRODUCT SELECTION GUIDE
FACTORY INSTALLED MDAQ DIFFERENTIAL signal conditioners:
To configure the D300-8 with MDAQ differential
signal conditioning, simply order the appropriate
PANEL - either the 2.0U high one which can hold
MDAQs with DSUB connectors (or half DSUB and
half BNC), or the 1.5U one which can hold up to 16
BNC connectors.The 1.5U high one, there is a 0.5U
high space still available for other PANELS that you
might want to have us install.
1.5U-PANEL-MDAQ-BNC
2.0U-PANEL-MDAQ
D300
2.0U-PANEL-MDAQ
Accepts any of our 8 channel MDAQ-SUB modules, regardless of connector type.
When this PANEL is installed, all 8 channels from the standard A/D card are connected to
these 8 signal conditioning inputs.
See below for MDAQ-SUB 8-channel conditioners.
OR...
1.5U-PANEL-MDAQ-BNC
Accepts any of our 8 channel MDAQ-SUB modules with BNC connectors only.
When this PANEL is installed, all 8 channels from the standard A/D card are connected to
these 8 signal conditioning inputs.
See below for MDAQ-SUB 8-channel conditioners.
MDAQ-SUB 8-channel conditioners (choose any ONE of these for the D300-8)
MDAQ-SUB-V200-BNC
MDAQ-SUB-V200-D
MDAQ-SUB-ACC-BNC
MDAQ-SUB-ACC-A-BNC
MDAQ-SUB-STG-D
MDAQ-SUB-BRIDGE-D
8 channel voltage module
16 selectable ranges from
±0.125V to ±200V.
Differential inputs.
CMV ±250 V.
Accuracy ±0.05%.
Bandwidth 300 kHz.
BNC connectors (8)
8 channel voltage
16 selectable ranges from
±0.125V to ±200V.
Differential inputs.
CMV ±250V.
Accuracy ±0.05%.
Bandwidth 300 kHz
±15 VDC fixed sensor supply
and programmable 0~12 VDC
sensor supply
TEDS support
9-pin DSUB connectors (8)
8 channel IEPE / low-voltage
input, selectable ranges of ±10,
5, 2.5, 1.25, 1, 0.5, 0.25 and
0.125 V; sensor power 4 / 8 mA
selectable. CMV ±12 V.
AC or DC coupling.
Differential / single-ended (voltage mode only).
Accuracy ±0.05%.
Bandwidth DC to 300 kHz.
Selectable 3.4 Hz high-pass
filter. TEDS support.
BNC connectors (8)
8 channel IEPE / low-voltage
input, selectable ranges of ±10,
5, 2.5, 1.25, 1, 0.5, 0.25 and
0.125 V; sensor power 4 / 8 mA
selectable. CMV ±12 V.
AC or DC coupling.
Differential (IEPE mode); single-ended (voltage mode).
Accuracy ±0.05%.
Bandwidth DC to 300 kHz.
Selectable 2 programmable
high pass filters: 0.16 Hz,
3.4 Hz.
TEDS support.
BNC connectors (8)
8 channel strain / low-voltage
input. Modes: full bridge, 1⁄2
bridge, 1⁄4 bridge 120 Ω, 1⁄4
bridge 350 Ω or voltage.
Full bridge sensors 120 Ω to
10 kΩ.
Internal completion for 1⁄2
bridge and 1⁄4 bridge sensors
internal 50 kΩ and 100 kΩ
shunt resistors
14 selectable ranges from
±0.5 to ±1000 mV/V (@ 5 V
excitation)
Voltage mode ranges from ±5
mV to ±10 V
Bandwidth DC to 30 kHz
Excitation voltage from 0~12
VDC. TEDS support
9-pin DSUB connectors (8)
8 channel bridge / low-voltage
input. Modes: full bridge, 1⁄2
bridge
Full bridge sensors 120 Ω to
10 kΩ.
Internal completion for 1⁄2
bridge sensors
AC/DC coupling
14 selectable ranges from
±0.5 to ±1000 mV/V (@ 5 V
excitation)
Voltage mode ranges from ±5
mV to ±10 V
Bandwidth DC to 30 kHz
Excitation voltage from 0~12
VDC. TEDS support
9-pin DSUB connectors (8)
Alternate version:
MDAQ-SUB-ACC-BNC-S1
Same as MDAQ-SUB-ACCBNC, except that the high-pass
filter is 1.6 Hz (typical for
structural analysis, modal, and
human body vibration)
Dewetron PRODUCT SELECTION GUIDE
17
D300-16 with SC4/MDAQ conditioners
The D300-16 is compatible with 16 channels of ISOLATED SC4 modules, or 16 channels of DIFFERENTIAL
MDAQ conditioners...
WITH MDAQ DIFFERENTIAL or SC4 ISOLATED SIGNAL CONDITIONERS
D300-16
◙◙
16 channel ORION-1616-100 PCI A/D card built-in
◙◙
16-bit resolution, simultaneous sampling, 100 kS/s per channel 8 synchronous TTL
digital I/Os
◙◙
2 synchronous TTL counter / encoder or 8 TTL digital inputs
◙◙
Includes DS-7-SE acquisition and analysis software
◙◙
Please add any 2.0U-PANEL-MDAQ (or 1.5U-PANEL-MDAQ) plus 2 x MDAQ-SUBs
OR please add 16 channels of SC4 series signal conditioners
(MDAQ and SC4 series conditioners cannot be mixed)
D300-16 upgrades
RAM-2048-3072
HARD DISK upgrades
UP-ORION-CAN2
UP-ORION-CTR8
Software upgrades
USB-ARINC or -1553
Upgrade the PC RAM from 1
GB to 2 GB or 3 GB
Change the HDD from a 500
GB spinning disk to a solid
state drive: 32, 64, or 128 GB.
Also, get a spare HDD
Adds two synchronous highspeed CAN BUS interfaces,
including DS-OPT-CAN software option, 2 x DB9’s
Upgrade from 8 TTL I/O lines
to 25V protected lines, and
from 2 advanced counters, to 8
advanced counters
Upgrade the basic version of
DS-7 from -SE to -PROF, or
-DSA.
Add a USB interface for ARINC
429 or MIL-STD-1553 interfaces to your system. Requires
software option PLUGINARINC/1553
A/D card upgrades
UP-ORION-16-22
UP-ORION-16-24
UP-ORION-100-500
UP-ORION-100-1000
DN-ORION-AD16-1000-16
Upgrade the A/D card from
16-bit to 22-bit with anti-aliasing filters (ORION-1622-100).
Max SR is still 100 kS/s/ch
Upgrade the A/D card from
16-bit to 24-bit with antialiasing filters (ORION-1624200). Max SR increases to 200
kS/s/ch
Upgrade the A/D card from max
SR of 100 kS/s/ch to 500 kS/s/
ch (ORION-1616-500). Bit resolution remains at 16-bits.
Upgrade the A/D card from max
SR of 100 kS/s/ch to 1000 kS/s/
ch (ORION-1616-1000). Bit
resolution remains at 16-bits.
Downgrade the standard A/D
card to a multiplexed type, 16
channels, 1000 kS/s (aggregate) max. SR.
D300-16 options & accessories
MOB-DISP-17
CTR-CBL-05
Software options
ACCELS
GPS sensor
VIDEO camera
Ruggedized mobile display with
capacitive touchscreen, 17”
diag, XGA resolution
Connection cable from counter
input (FGG.1B.307) to open
end, length 5 m.
Add software options like order
tracking, sound level meter,
modal analysis, balancing,
and more.
Dewetron offers DYTRAN IEPE
accelerometers, which are perfectly suited to the D3PC-4
You can add a simple USB
GPS sensor with 1 Hz update
rate, or one of our 20/100 Hz
GPS sensors for incredible
precision.
A common webcam can be connected to the USB port, allowing you to record video in sync
with your data
18
Dewetron PRODUCT SELECTION GUIDE
FACTORY INSTALLED MDAQ DIFFERENTIAL signal conditioners:
To configure the D300-16 with MDAQ differential
signal conditioning, simply order the appropriate
PANEL - either the 2.0U high one which can hold
MDAQs with DSUB connectors (or half DSUB and
half BNC), or the 1.5U one which can hold up to 16
BNC connectors.The 1.5U high one, there is a 0.5U
high space still available for other PANELS that you
might want to have us install.
1.5U-PANEL-MDAQ-BNC
2.0U-PANEL-MDAQ
D300
2.0U-PANEL-MDAQ
Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type.
When this PANEL is installed, all 16 channels from the standard A/D card are connected
to these 16 signal conditioning inputs.
See below for MDAQ-SUB 8-channel conditioners.
OR...
1.5U-PANEL-MDAQ-BNC
Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only.
When this PANEL is installed, all 16 channels from the standard A/D card are connected
to these 16 signal conditioning inputs.
See below for MDAQ-SUB 8-channel conditioners.
MDAQ-SUB 8-channel conditioners (choose 2, or 2 of the same one)
MDAQ-SUB-V200-BNC
MDAQ-SUB-V200-D
MDAQ-SUB-ACC-BNC
MDAQ-SUB-ACC-A-BNC
MDAQ-SUB-STG-D
MDAQ-SUB-BRIDGE-D
8 channel voltage module
16 selectable ranges from
±0.125V to ±200V.
Differential inputs.
CMV ±250 V.
Accuracy ±0.05%.
Bandwidth 300 kHz.
BNC connectors (8)
8 channel voltage
16 selectable ranges from
±0.125V to ±200V.
Differential inputs.
CMV ±250V.
Accuracy ±0.05%.
Bandwidth 300 kHz
±15 VDC fixed sensor supply
and programmable 0~12 VDC
sensor supply
TEDS support
9-pin DSUB connectors (8)
8 channel IEPE / low-voltage
input, selectable ranges of ±10,
5, 2.5, 1.25, 1, 0.5, 0.25 and
0.125 V; sensor power 4 / 8 mA
selectable. CMV ±12 V.
AC or DC coupling.
Differential / single-ended (voltage mode only).
Accuracy ±0.05%.
Bandwidth DC to 300 kHz.
Selectable 3.4 Hz high-pass
filter. TEDS support.
BNC connectors (8)
8 channel IEPE / low-voltage
input, selectable ranges of ±10,
5, 2.5, 1.25, 1, 0.5, 0.25 and
0.125 V; sensor power 4 / 8 mA
selectable. CMV ±12 V.
AC or DC coupling.
Differential (IEPE mode); single-ended (voltage mode).
Accuracy ±0.05%.
Bandwidth DC to 300 kHz.
Selectable 2 programmable
high pass filters: 0.16 Hz,
3.4 Hz.
TEDS support.
BNC connectors (8)
8 channel strain / low-voltage
input. Modes: full bridge, 1⁄2
bridge, 1⁄4 bridge 120 Ω, 1⁄4
bridge 350 Ω or voltage.
Full bridge sensors 120 Ω to
10 kΩ.
Internal completion for 1⁄2
bridge and 1⁄4 bridge sensors
internal 50 kΩ and 100 kΩ
shunt resistors
14 selectable ranges from
±0.5 to ±1000 mV/V (@ 5 V
excitation)
Voltage mode ranges from ±5
mV to ±10 V
Bandwidth DC to 30 kHz
Excitation voltage from 0~12
VDC. TEDS support
9-pin DSUB connectors (8)
8 channel bridge / low-voltage
input. Modes: full bridge, 1⁄2
bridge
Full bridge sensors 120 Ω to
10 kΩ.
Internal completion for 1⁄2
bridge sensors
AC/DC coupling
14 selectable ranges from
±0.5 to ±1000 mV/V (@ 5 V
excitation)
Voltage mode ranges from ±5
mV to ±10 V
Bandwidth DC to 30 kHz
Excitation voltage from 0~12
VDC. TEDS support
9-pin DSUB connectors (8)
Alternate version:
MDAQ-SUB-ACC-BNC-S1
Same as MDAQ-SUB-ACCBNC, except that the high-pass
filter is 1.6 Hz (typical for
structural analysis, modal, and
human body vibration)
Dewetron PRODUCT SELECTION GUIDE
19
D300-8 / -16 with SC4 conditioners
RACKS for FACTORY INSTALLED SC4 ISOLATED signal conditioners:
If you want to configure the D300-16 with SC4
isolated signal conditioning, simply select any four
of the SC4 conditioners, which include the 0.5U high
panel that the connectors are mounted on, as well as
the conditioners that are installed inside the system.
You can choose any combination of SC4 modules,
including all four the same, or all different, etc. Most
SC4 conditioners are isolated to 1500V RMS.
0.5U PANEL SLOT 1
0.5U PANEL SLOT 2
0.5U PANEL SLOT 3
0.5U PANEL SLOT 4
D300
SC4 series ISOLATED 4-channel conditioners - choose any combination of four
LOW VOLTAGE
SC4-10mV-BNC
SC4-100mV-BNC
SC4-1V-BNC
SC4-10V-BNC
SC4-20V-BNC
SC4-40V-BNC
Analog input channels
4
4
4
4
4
4
Full scale input range
±10 mV
±100 mV
±1 V
±10 V
±20 V
±40 V
Bandwidth (-3 dB point)
10 kHz
10 kHz
10 kHz
10 kHz
10 kHz
10 kHz
CMV (isolation)
1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1)
100 dB
100 dB
100 dB
CMR (50 or 60 Hz)
100 dB
NMR
(–3 dB at 10 kHz) 120 dB per decade above 10kHz
100 dB
100 dB
Accuracy
±0.03% span
±0.03% span
±0.03% span
±0.03% span
±0.03% span
±0.03% span
Linearity
±0.01% span
±0.01% span
±0.01% span
±0.01% span
±0.01% span
±0.01% span
Input protection
240 Vrms max.
240 Vrms max.
240 Vrms max.
240 Vrms max.
240 Vrms max.
240 Vrms max.
Output protection
Continuous short to
ground
Continuous short to
ground
Continuous short to
ground
Continuous short to
ground
Continuous short to
ground
Continuous short to
ground
Input resistance
Normal 200 MΩ, Power
off: 40 kΩ, Overload:
40 kΩ
Normal 200 MΩ, Power
off: 40 kΩ, Overload:
40 kΩ
Normal 200 MΩ, Power
off: 40 kΩ, Overload:
40 kΩ
Normal/Power off/
Overload: 650 kΩ minimum
Normal/Power off/
Overload: 650 kΩ minimum
Normal/Power off/
Overload: 650 kΩ minimum
Connectors:
Four insulated BNC input connectors on a 0.5U panel
HIGH VOLTAGE
SC4-100V-B
SC4-200V-B
SC4-400V-B
SC4-1000V-B
Analog input channels
4
4
4
4
Full scale input range
±100 V
±200 V
±400 V
±1000 V
Bandwidth (-3 dB point)
10 kHz
10 kHz
10 kHz
10 kHz
CMV (isolation)
1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1)
CMR (50 or 60 Hz)
100 dB
NMR
(–3 dB at 10 kHz) 120 dB per decade above 10kHz
100 dB
100 dB
100 dB
±0.03% span
Accuracy
±0.03% span
±0.03% span
±0.03% span
Linearity
±0.01% span
±0.01% span
±0.01% span
±0.01% span
Input protection
240 Vrms max.
240 Vrms max.
240 Vrms max.
240 Vrms max.
Output protection
Continuous short to
ground
Continuous short to
ground
Continuous short to
ground
Continuous short to
ground
Input resistance
Normal 200 MΩ, Power
off: 40 kΩ, Overload:
40 kΩ
Normal 200 MΩ, Power
off: 40 kΩ, Overload:
40 kΩ
Normal 200 MΩ, Power
off: 40 kΩ, Overload:
40 kΩ
Normal/Power off/
Overload: 650 kΩ minimum
Connectors:
Four insulated banana jack input connectors on a 0.5U panel
Note - when SC4 high voltage modules are used, the D300-16 is limited to 8 dynamic input channels.
20
Dewetron PRODUCT SELECTION GUIDE
RTD
SC4-RTD-P1002W3W
SC4-RTD-P1004W
CURRENT
SC4-LA-4-20mA
Analog input channels
4
Analog input channels
4
4
Full scale range:
4 - 20 mA
Linearization
Fully linearized
Fully linearized
Bandwidth (-3 dB point)
4 Hz
Full scale range:
-100°C to +200°C
-100°C to +200°C
CMV (isolation)
Sensor compatibility
100 Ω Platinum RTD
100 Ω Platinum RTD
Wiring modes
2 and 3-wire configurations only
4-wire configuration only
1500 Vrms maximum
continuous (transient
according to ANSI/IEEE
C37.90.1)
Bandwidth (-3 dB point)
4 Hz
4 Hz
NMR
95dB at 60Hz, 90dB at
50Hz
CMV (isolation)
1500 Vrms maximum continuous (transient according to
ANSI/IEEE C37.90.1)
Accuracy
±0.03% Span
Input protection
240 Vrms max.
Connectors:
Four insulated DB9 input
connectors on a 0.5U
panel
NMR
95 dB at 60 Hz, 90 dB at 50 Hz
Accuracy
±0.18°C
±0.18°C
Input protection
240 Vrms max.
240 Vrms max.
Connectors:
Four insulated DB9 input connectors on a 0.5U panel
THERMOCOUPLES
SC4-TH-J
SC4-TH-K
SC4-TH-T
Analog input channels
4
4
4
Bandwidth (-3 dB point)
4 Hz
4 Hz
4 Hz
CMV (isolation)
1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1)
Linearization
Fully linearized with automatic CJC
NMR
95 dB at 60 Hz, 90 dB at 50 Hz
Accuracy
±0.08% (±0.61°C)
±0.08% (±0.61°C)
±0.08% (±0.61°C)
Input protection
240 Vrms max.
240 Vrms max.
240 Vrms max.
Connectors:
Four insulated miniature thermocouple input connectors on a 0.5U panel
BRIDGE/STRAIN
SC4-BRF-3V3mV
SC4-BRF-10V2mV
SC4-BRH-3V3mV
Analog input channels
4
4
4
Bridge mode
FULL bridge
FULL bridge
HALF bridge
Full scale range:
100 Ω to 10 kΩ
300 Ω to 10 kΩ
100 Ω to 10 kΩ
300 Ω to 10 kΩ
Excitation Voltage
3 V
10 V
3 V
10 V
SC4-BRH-10V2mV
HALF bridge
Sensitivity
3 mV/V
2 mV/V
3 mV/V
3 mV/V
Bandwidth (-3 dB point)
10 kHz
10 kHz
10 kHz
10 kHz
CMV (isolation)
1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1)
Linearity
±0.01% Span
NMR
120 dB per decade above 10kHz
±0.01% Span
±0.01% Span
±0.01% Span
Accuracy
±0.03% Span
±0.03% Span
±0.03% Span
±0.03% Span
Input protection
240 Vrms max.
240 Vrms max.
240 Vrms max.
240 Vrms max.
Output protection
Continuous short to
ground
Continuous short to
ground
Continuous short to
ground
Continuous short to
ground
Connectors:
Four insulated DB9 input connectors on a 0.5U panel
D300-16 typical applications
VEHICLE / CAN / GPS testing
BURN-IN and LIFE-CYCLE testing
SHOCK RESPONSE SPECTRUM testing
GENERAL PURPOSE testing
The 16 inputs can be configured with every
kind of sensor: strain, accel, voltage, current,
temperature, and more. Add two CAN BUS
interfaces to add vehicle data, and a GPS
sensor to record vehicle speed, position,
heading, and other parameters.
The D300-16 is versatile enough to handle
just about any data acquisition application,
including factory burn-inm HALT and HASS
testing, of satellite components, vehicle parts,
motors and turbines, manufacturing equipment, and more.
With its 16 dynamic IEPE inputs, the D30016 makes a great SRS instrument. Configure
your inputs for charge, IEPE, or strain gages,
voltages, and more. Get the UP-ORION-16-24
upgrade, the DS-OPT-SRS software option,
and your sensors.
Any basic data acquisition application where
you need a small footprint self contained data
acquisition instrument with great dynamic
specifications (24-bit, 200 kS/s/ch, anti-aliasing)... at a great price point!
Dewetron PRODUCT SELECTION GUIDE
21
D300 expansion guide
32-channel ORION card
in D300-16 mainframe
Expansion via analog cable
A very popular way of expanding the analog
inputs is to upgrade the ORION card from 16
to 32 dynamic channels, then connect external
signal conditioning amplifiers via an analog cable.
Simply upgrade the D300-16 to have 32 A/D
channels inside via either the UP-ORION-16-22-32
(22-bit @ 100 kS/s/ch) or the UP-ORION-1616-32
option (16-bit @ 100 kS/s/ch), then add an
external 16 channel conditioning chassis and
cable. Choose from MDAQ or DAQ / HSI series
plug-in conditioners.
AN
A LO
PO
G SIGNALS
WE
PP
R SU
LY
AC (optional DC)
power supply
DEWE-31-16 or
DEWE-30-16 expansion
chassis
Expansion chassis
DEWE-30-16
DEWE-31-16
Amplifier slots
16
-8 or 16
MDAQ channels
--
A/D converter
(Connects to the A/D card in the main system - there is no A/D
converter inside any DEWE-30 or DEWE-31 chassis)
Power supply (standard)
120/230 VAC 50/60 Hz
DC from the mainframe or via
AC/DC adapter
Dimensions (WxDxH)
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in
Weight
4 kg (9 lbs)
1.6 kg (3.5 lbs)
Expansion via PCI bridge
The PCI expansion is an alternative especially if high channel count
is needed. The best mainframe to use is the D3PC computer chassis,
which has no inputs of its own, but it will contain the PCI bridge card
and run the whole system. The DEWE-50, DEWE-51 and DEWE-52 ADC
racks can be connected by a 1m PCI cables. ORION series cards are
installed inside the DEWE-5x unit and you simply have to select the
suitable signal amplifiers for your needs.
AC (optional DC)
power supply
D3PC with PCI
PCI H
OST
bridge card
inside
In this way, the D3PC can serve as the host of a system with dozens,
hundreds, or even more than 1000 dynamic input channels!
SY N C
Important notice: Each DEWE-50/51/52 chassis must be equipped with
ORION-SYNC option.
DEWE-52-PCI-3216
Expansion chassis
DEWE-50-PCI-32
DEWE-50-PCI-64
DEWE-51-PCI-32
DEWE-51-PCI-128
DEWE-52-PCI-3216
Amplifier slots
32
64
--
--
16
MDAQ channels
--
--
Up to 64
Up to 128
Up to 32
ORION card slots
3
7
7
13
7
Power supply (standard)
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
Dimensions (WxDxH)
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in.
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
408 x 287 x 267 mm
16.1 x 11.3 x 10.5 in
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
Weight
10 kg (22 lbs)
15 kg (33 lbs)
6 kg (13 lbs)
9 kg (20 lbs)
9 kg (20 lbs)
22
Dewetron PRODUCT SELECTION GUIDE
Expansion via Ethernet
The NET expansion is a fantastic way to
combine two or more DEWE instruments to
one multichannel system. Each instrument
must have installed hardware option ORIONSYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First is
a simple cable connection for distances up to
200 m, second one is GPS- or DEWE-CLOCK
which is useful for long distances when a
cable connection is not possible. DS-OPTNET software offers full remote setup, online
data transfer up to the limit of the network
connection and offline data transfer between
the instruments.
User tip: The NET expansion also distributes
the data processing load among multiple
computers, each of which can store data at full
speed.
Specifications
Specification
D300 series
Direct Voltage / IEPE inputs:
D3PC-4: 4 channels
D3PC-8: 8 channels
MDAQ-SUB positions
D300-16: 2 positions (16 channels)
SC4 positions
D300-16: 4 positions (16 channels)
Main system
Total PCI slots
1 x half-length PCI slots
Hard disk
500 GB standard removable drive (optional solid state drive)
Data throughput to disk
50 MB/s typical; faster rates available with the additional of an internal
RAID controller and/or additional drives
Power supply
9~29 VDC. Includes external AC/DC power adapter for operating the system from 120/240 VAC 50/60 Hz.
Processor
Intel Core2Duo 2.0 GHz CPU, on a standard industrial grade MiniITX
mainboard
RAM
2 GB (expandable to 4 GB)
Computer interfaces:
2 x Gb ethernet; 4 x USB 2.0; 1 x RS232 serial (DB9 connector)
Operating system
Microsoft Windows7 32-bit included (64-bit available Q4 2012)
Dimensions (W x D x H)
(without bumpers)
D3PC: 8.5 x 4.75 x 10.78 (216 x 121 x 274 mm)
D300: 14.5 x 4.75 x 10.78 (368 x 121 x 274 mm)
Weight
D3PC models: 4 kg typical (~9 lbs)
D300-16 models: 5.5 kg typical (~12 lbs)
Environmental specifications
Operating temperature
-20 to 50°C (0 to 45°C with batteries installed) (storage temp -20 to 60C)
Humdity
10 to 80% non-condensing, 5 to 95% relative humidity
Vibration
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock
MIL-STD-810F, EN 60068-2-27
Data acquisition specifications
D3PC-4 model:
Includes ORION-0424-200 A/D card (IEPE signal conditioning included)
4 different input ranges: ±0.1V, ±0.5V, ±2V, ±10V
4 BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support
24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, antialiasing filters
Single-ended or differential inputs, software selectable
AC (0.15 or 3.4 Hz) or DC coupled
One synchronous advanced counter/encoder with programmable threshold
levels (0 ~ 40 V), input voltage range -35 ~ 60 V, DB9 connector
External trigger input
D3PC-8 model:
Includes ORION-0824-200 A/D card (IEPE signal conditioning included)
4 different input ranges: ±0.1V, ±0.5V, ±2V, ±10V
8 BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support
24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, antialiasing filters
Single-ended or differential inputs, software selectable
AC (0.15 or 3.4 Hz) or DC coupled
Two synchronous advanced counters/encoders with programmable threshold levels (0 ~ 40 V), input voltage range -35 ~ 60 V, LEMO connectors
8 synchronous TTL digital I/Os and one external trigger input, DB37
D300-16 model:
Includes ORION-1616-100 A/D card (requires signal conditioning)
100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100)
Please order your choice of either 4 x SC4 conditioners, or MDAQ PANEL
and SUB modules to complete this system.
Upgrades to faster cards, and higher resolution cards available
D300-16 A/D card upgrades:
UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing
UP-ORION-16-22-32: upgrade to 22-bit with 102.4 kS/s/ch and from 16 to
32 channels
UP-ORION-16-24: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing
UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch
UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch
UP-ORION-1616-3216: upgrade from 16 channels to 32 channels (100
kS/s/ch maximum sample rate @ 16-bit resolution)
Data acquisition software:
DS-7-SE is included as standard
Software upgrades available:
To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS
D300-16 EPAD interface:
Standard LEMO 4-pin connector. EPAD2 modules are daisy-chainable
D3PC-8
D300-16
SYNC
ETHERNE
T
0.000 ms
D300-16
GPS-CLOCK
SYNC
External channel expansion
Low-speed channel expansion:
Up to 16 EPAD2 modules can be connected to the EPAD connector, adding
up to 128 channels of low-speed thermocouple, voltage, RTD, and current
inputs, in blocks of eight channels
Expansion via analog cable:
D300-16 only - first upgrade the internal A/D card to have 32 channels:
UP-ORION-1616-3216 upgrades the std card from 16 to 32 channels
UP-ORION-16-22-32 upgrades the std card from 16 to 32 channels, and
from 16-bit to 22-bit resolution with anti-aliasing filtering
D300-16 only - then add an external 16 channel chassis of conditioning
(see optional expansion chassis on this page)
Expansion via PCI bridge:
Up to 256 total dynamic analog input channels (with PCI bridge card
installed inside the D3PC, and external DEWE-50/51 chassis connected.
Expansion via ethernet:
Up to 2000 total dynamic analog input channels (with SYNC option for
local connections, or IRIG/GPS sync for remote connections, and multiple
remote DEWE systems synchronized via DS-OPT-NET software option.
GPS-CLOCK
D3PC-8
SYNC
ETHER
NET
Dewetron PRODUCT SELECTION GUIDE
23
DEWE-3210 with 16 MDAQ
channels
DEWE-3210 with
8 DAQ modules
DEWE-3210 series
www.dewamerica.com/Products/DEWE-3210
OVERVIEW
The DEWE-3210 is our most popular PORTABLE
data acquisition instrument. It has a 16-channel A/D
card installed already, with 100 kS/s/ch simultaneous
sampling and 16-bit resolution. Our DS-7 software is
also included!
Simply choose between our plugin modules or
factory installed MDAQ signal conditioners in order to
complete your system.
If you configure it with 8 of our plugin modules, the
other 8 channels are available on a connector so that
you can use one of our external expansion boxes.
The factory installed MDAQ conditioners provide all 16
channels with conditioners right on the side panel.
Digital inputs are counters are standard. You can
add many options, including interfaces for CAN BUS,
ARINC, 1553, VIDEO, IRIG, GPS, cameras, and more.
24
Dewetron PRODUCT SELECTION GUIDE
◙◙ 16 channel, 100 kS/s/ch simultaneous
sampling A/D card card inside
◙◙ DS-7-SE software included
◙◙ Choose from DAQ or MDAQ series signal
conditioners
◙◙ 500 GB removable HDD
◙◙ Built-in TOUCHSCREEN display
◙◙ 17” display, 1280x1024 resolution
◙◙ Keyboard built-in below the screen
◙◙ Battery power - runs 2-3 hours without any
external power connected
◙◙ Batteries are hot-swappable - even during
measurement
◙◙ Ruggedized construction, MIL-STD, ENSTD, and more
◙◙ Made in USA
◙◙ Full year warranty
Applications
◙◙
General purpose data acquisition
◙◙
Field service and field test applications
◙◙
Energy test
◙◙ Vehicle test
◙◙ Aircraft tests
◙◙
Railcar test
◙◙
Noise & vibration
◙◙ All kinds of trouble-shooting
◙◙
Every kind of mechanical and structural test
BUILT TO LAST
We build the DEWE-3210 in the same USA factory
where Dewetron’s BATTERY POWER technology
was invented back in 2004. After delivering
hundreds of instruments, and then doing the
maintenance and repairs on them, we know what
breaks, and what doesn’t. This experience feeds
directly back into the next revision, ensuring that
each one gets better and more reliable than the
one before. That’s the continuous improvement that
ensures your investment in a DEWE-3210 is a good
one, and for years to come.
The computer connections are
protected behind a metal door
REAL PORTABILTY
The DEWE-3210 features our BATTERY POWER
technology as a standard feature. You get about
an hour from each hot-swappable battery (two are
included, a third is optional). Even if you don’t need
battery operation per se, what a great UPS this
makes! If power is lost for whatever reason, the
system keeps running without interruption, instantly
switching from AC to battery power, and back again,
as needed.
Dewetron PRODUCT SELECTION GUIDE
25
DEWE-3210 configuration guide
To complete your DEWE-3210, you just need to choose the signal conditioners that you want. There are two
basic choices: plug-in DAQ/HSI modules, or factory installed MDAQ conditioners. Choose plug-in modules
when you need single channel modularity and ISOLATION. Choose MDAQ conditioners when differential
inputs are OK, and you want as many channels as possible on the mainframe.
The DEWE-3210 has one 2.0U PANEL space on its left side: phoose ONE of these PANELS to be factory
installed, then choose the conditioners that you want in it!
RACKS for PLUG-IN Isolated signal conditioners:
2.0U-PANEL-RACK8
Accepts up to 8 of our plugin DAQ and PAD series signal conditioning modules.
(Compatible also with all HSI modules, except that it limits their bandwidth to 300 kHz)
When this RACK is installed, the other 8 A/D channels will be brought to a nearby
connector so that you can easily attach one of our expansion RACKS and utilize the other
8 dynamic input channels.
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
OR...
2.0U-PANEL-RACK8-HSI
Accepts up to 8 of our plugin HSI series signal conditioning modules. Also compatible
with most DAQ and PAD series modules (not compatible with DAQP-CHARGE-A and
DAQP-FREQ-A and other very old DAQ modules).
When this RACK is installed, the other 8 A/D channels will be brought to a nearby
connector so that you can easily attach one of our expansion RACKS and utilize the other
8 dynamic input channels.
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
OR...
RACKS for FACTORY INSTALLED differential signal conditioners:
2.0U-PANEL-MDAQ
Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type.
When this RACK is installed, all 16 channels from the standard A/D card are connected to
these 16 signal conditioning inputs.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
OR...
1.5U-PANEL-MDAQ-BNC
Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only.
When this RACK is installed, all 16 channels from the standard A/D card are connected to
these 16 signal conditioning inputs.
Note: an additional 0.5U space is available for small connector panels to be installed
here!
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
26
Dewetron PRODUCT SELECTION GUIDE
2.0U-PANEL-RACK8 2.0U-PANEL-MDAQ
1.5U-PANEL-MDAQ-BNC
FACTORY INSTALLED upgrades available at the time of ordering:
UP-ORION-CAN2
Adds two high speed CAN BUS interfaces, the DB9 connectors, and the software option inside DS-7.
UP-ORION-CTR8
Upgrades the digital inputs to 8 TTL digital inputs protected
up to 25 VDC, and 8 counter/encoder inputs with programmable threshold (0-40VDC) and -35 to 60V range, AC/DC
coupling. Includes DB37 connector and mate.
UP-ORION-16-22
Upgrade the A/D card to 22-bit resolution with anti-aliasing
filtering, with 100 kS/s/ch max sample rate.
UP-ORION-16-24
Upgrade the A/D card to 24-bit resolution with anti-aliasing
filtering, with 200 kS/s/ch max sample rate.
UP-ORION-100-500
Upgrade the A/D card to 500 kS/s/ch max sample rate.
UP-ORION-100-1000
Upgrade the A/D card to 1000 kS/s/ch max sample rate.
DN-ORION-AD16-1000-16
Downgrade the A/D card to multiplexed 16-bit card with
1MS/s/ aggregate sample rate, 2 simple counters, and 8
TTL digital I/O lines.
ORION-SYNC
Installs a SYNC interface and in/out RJ45 connectors for
multi-system synchronization
3210-DC-POWER
Upgrades the power system to run from a wider DC range:6
to 30 VDC max. (instead of 18-24 VDC max).
RAM-2048-3072
Upgrades the computer RAM from 2 GB to 3 GB
RAM-2048-4096
Upgrades the computer RAM from 2 GB to 4 GB
HDD-SDD-32
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 32 GB size
HDD-SDD-64
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 64 GB size
HDD-SDD-128
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 128 GB size
HDD-SDD-256
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 256 GB size
There are other options and upgrades available - please consult your DEWETRON
representative for the latest information, and for pricing.
Dewetron PRODUCT SELECTION GUIDE
27
DEWE-3210 expansion guide
Expansion via analog cable
A very popular way of expanding the analog
inputs is to install more ORION cards into
the instrument and connect external signal
conditioning amplifiers via analog cables. Each
DEWE-3210 instrument has two spare PCI-slots
which can be used to install additional ORION
cards. Select a suitable external DEWE-30 or
DEWE-31 series signal conditioning rack, the
required amplifiers and directly connect the
analog outputs to the ORION cards by analog
signal cables.
DEWE-ORION card
in main system
AN
A LO
PO
WE
ALS
G SIGN
PP
R SU
LY
AC (optional DC)
power supply
DEWE-31-12
Expansion chassis
DEWE-30-8
DEWE-30-16
DEWE-30-32
DEWE-31-16
DEWE-31-32
Amplifier slots
8
16
32
--
--
--
--
8 or 16
8, 16, 24 or 32
MDAQ channels
--
A/D converter
(Connects to the A/D card in the main system - there is no A/D converter inside any DEWE-30 or DEWE-31 chassis)
Power supply (standard)
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
DC from the mainframe or via
AC/DC adapter
120/230 VAC 50/60 Hz
Dimensions (WxDxH)
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
435 x 223 x 245 mm
16.1 x 13/4 x 7.9 in
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
Weight
4 kg (9 lbs)
7 kg (15 lbs)
1.6 kg (3.5 lbs)
4 kg (9 lbs)
Expansion via PCI bridge
The PCI expansion is an alternative especially if high channel count is
needed. When using an expansion only one PCI slot is occupied in the
DEWE-3210 instrument by a PCI-HOST-CARD. The DEWE-50, DEWE-51
and DEWE-52 ADC racks can be connected by a 1m PCI cable. The
ORION cards are installed inside the DEWE-5x unit and you simply
have to select the suitable signal amplifiers for your needs.
AC (optional DC)
power supply
Important notice: The DEWE-3210 and the DEWE-5x must be equipped
with ORION-SYNC option.
DEWE-3210
PCI H
OST
SY N C
User tip: with an additional ECARD-34 or 54 the DEWE-5x also can
be used as an independent system in combination with a laptop
computer.
DEWE-52-PCI-3216
Expansion chassis
DEWE-50-PCI-32
DEWE-50-PCI-64
DEWE-51-PCI-32
DEWE-51-PCI-128
DEWE-52-PCI-3216
Amplifier slots
32
64
--
--
16
MDAQ channels
--
--
Up to 64
Up to 128
Up to 32
ORION card slots
3
7
7
13
7
Power supply (standard)
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
Dimensions (WxDxH)
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in.
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
408 x 287 x 267 mm
16.1 x 11.3 x 10.5 in
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
Weight
10 kg (22 lbs)
15 kg (33 lbs)
6 kg (13 lbs)
9 kg (20 lbs)
9 kg (20 lbs)
28
Dewetron PRODUCT SELECTION GUIDE
Specifications
Expansion via Ethernet
The NET expansion is a fantastic way to
combine two or more DEWE instruments to
one multichannel system. Each instrument
must have installed hardware option ORIONSYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First
is a simple cable connection for distances up
to 200 m, second one is GPS- or IRIG-CLOCK
which is useful for long distances when a
cable connection is not possible. DS-OPTNET software offers full remote setup, online
data transfer up to the limit of the network
connection and offline data transfer between
the instruments.
User tip: The NET expansion also distributes
the data processing load among multiple
computers, each of which can store data at full
speed.
Specification
DEWE-3210
Slots for DAQ/PAD/HSI modules
8 with 2.0U-PANEL-DAQ or -HSI
MDAQ-SUB positions
2 with 2.0U-PANEL-MDAQ or 1.5U-PANEL-MDAQ-BNC
Main system
Total PCI slots
3 x half-length PCI slots
Hard disk
500 GB standard removable drive (optional solid state drive)
Data throughput to disk
50 MB/s typical; faster rates available with the additional of an internal
RAID controller and/or additional drives
Power supply
Hot-swappable batteries, operates from 18~24 VDC. Includes DPS-2410
external AC/DC power adapter for recharging the batteries and operating
the system from AC mains.
Display
17” SXGA display, 1280 x 1024 px, with standard resistive touchscreen
Processor
Intel Core2Duo 2.0 GHz CPU, on a standard industrial grade MiniITX
mainboard
RAM
2 GB (expandable to 4 GB)
Ethernet
2 x Gb ethernet interfaces
USB
Four x USB 2.0 interfaces
RS232 serial interface
One serial interface (DB9 connector)
Optical drive
DVD+-CD-RW drive built-in. CD burning capability included
Operating system
Microsoft Windows7 32-bit included
Dimensions (W x D x H)
425 x 340 x 191 mm (16.7 x 13.4 x 7.5 in.)
Weight
10 kg typical (22 lbs)
Environmental specifications
Operating temperature
-20 to 50C (0 to 45C with batteries installed) (storage temp -20 to 60C)
Humdity
10 to 80% non-condensing, 5 to 95% relative humidity
Vibration
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock
MIL-STD-810F, EN 60068-2-27
Data acquisition specifications
DEWE-3210
DEWE-3210
SYNC
ETHERNE
T
Standard A/D card specifications:
100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100)
Upgrades to faster cards, and higher resolution cards available
Available A/D card upgrades:
UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing
UP-ORION-16-22: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing
UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch
UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch
Data acquisition software:
DS-7-SE is included as standard
Software upgrades available:
To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS
Analog inputs:
16, according to the installed DAQ, PAD, HSI, or MDAQ signal conditioners
Signal conditioning available:
Isolated/differential conditioners for low voltage, high voltage, strain,
bridge, pressure, thermocouples, RTDs, IEPE, charge
EPAD interface:
Standard LEMO 4-pin connector, right side panel
Computer upgrades
RAM upgrades:
Increase from 2 to 3 GB or 4 GB
Hard disk drive upgrade:
Add an internal drive, or increase the size of the removable drive, or convert the removable drive to a solid state drive
Filtering upgrades:
DAQ/HSI modules have filters built-in
MDAQ-FILT options available for MDAQ systems
Popular interfaces
0.000 ms
CAN BUS interfaces:
UP-ORION-CAN2 adds 2 high-speed synchronous CAN BUS interfaces on
DB9 connectors, and DS-OPT-CAN software option
Time code interface:
Adds an internal IRIG or GPS time code interface (does not require a PCI
slot)
VIDEO-FG-4
Adds a four channel VIDEO INPUT PCI card to the system. Four BNCs
for analog NTSC video input on the right side panel, allowing four video
streams to be recorded in sync with the data
ARINC-429
Several different interface cards are available with various numbers of
ARINC 429 transmit and receive channels
MIL-STD-1553
Several different interface cards are available with various numbers of MILSTD-1553 transmit and receive channels
GPS-CLOCK
External channel expansion
DEWE-3050
SYNC
Low-speed channel expansion:
Up to 16 EPAD2 modules can be connected to the EPAD connector, adding
up to 128 channels of low-speed thermocouple, voltage, RTD, and current
inputs, in blocks of eight channels
Expansion via analog cable:
Up to 96 total dynamic analog input channels (with three 32-channel A/D
cards installed inside the DEWE-3210, and external DEWE-30/31 chassis
connected.
Expansion via PCI bridge:
Up to 256 total dynamic analog input channels (with PCI bridge card
installed inside the DEWE-3210, and external DEWE-50/51 chassis connected.
Expansion via ethernet:
Up to 2000 total dynamic analog input channels (with SYNC option for local
connections, or IRIG/GPS sync for remote connections, and multiple remote DEWE systems synchronized via DS-OPT-NET software option.
GPS-CLOCK
DEWE-3210
SYNC
ETH
T
ERNE
Dewetron PRODUCT SELECTION GUIDE
29
DEWE-3210 ordering guide
Please use the table below to configure your DEWE-3210 system. From this ordering guide, your DEWETRON representative
can create a detailed price quote for you.
First, please choose your basic model:
DEWE-3210
Portable battery-powered data acquisition system
16-bit resolution, simultaneous sampling, 100 kS/s per channel
8 synchronous TTL digital I/Os
2 synchronous TTL counter / encoder or 8 TTL digital inputs
2.0U panel space available for signal conditioners
Choose from plugin DAQ / PAD / HSI series conditioning modules or
MDAQ differential signal conditioning inputs (16 channels) or a combination
2 free PCI slots (3 half length PCI slots inside when any PANEL is installed, 1 is used by the standard A/D card)
EPAD2 connector for optional EPAD2 modules. DS-7-SE software is included
NEXT, please choose the SIGNAL CONDITIONING PANEL(S) that you need (factory installed, See previous pages for possibilities):
2.0U-PANEL-RACK8
2.0U Card cage for up to 8 DAQ / HSI / PAD module slots, 300 kHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
2.0U-PANEL-RACK8-HSI
2.0U Card cage for up to 8 HSI / DAQ / PAD module slots, 2 MHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
Not compatible with the DAQP-CHARGE-A, DAQP-FREQ-A, and certain older DAQ modules
2.0U-PANEL-MDAQ-DSUB
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where either or both of have 9-pin DSUB connectors.
Please order your choice of MDAQ-SUB-XX-D conditioners separately (2 required).
1.5U-PANEL-MDAQ-BNC
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where both have BNC connectors. Please order your
choice of MDAQ-SUB-XX-BNC conditioners separately (2 required).
ADDITIONAL AVAILABLE connector panels
0.5U-ORION-CNT2-LEMO
0.5 U panel with 2 LEMO connectors EGG.1B.307 connected to the 2 counters of an ORION base card, incl. mating connectors
0.5U-AMPFLEX-POWER-8
0.5 U panel with 8 Binder 712 connectors, 9 V Power supply for PNA-A100 current transducers
0.5U-CLAMP-DC-POWER-4
0.5 U panel with 4 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
0.5U-CLAMP-DC-POWER-8
0.5 U panel with 8 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
0.5U-DA2-BNC
0.5 U panel with 2 BNC connectors connected to the 2 analog outputs of an AD16-1000-16-OUT2 card
0.5U-DA4-BNC
0.5 U panel with 4 BNC connectors connected to the 4 analog outputs of a DA4-1000-16 card
0.5U-DA8-BNC
0.5 U panel with 4 BNC connectors connected to the 8 analog outputs of a DA8-1000-16 card
please choose any A/D card upgrades that you require (factory installed only):
UP-ORION-16-22
Upgrade the standard 16-channel A/D card from 16-bit resolution to 22-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1622-100). The max. sample rate remains at 100 kS/s/ch.
UP-ORION-16-24
Upgrade the standard 16-channel A/D card from 16-bit resolution to 24-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1624-200). The max. sample rate increases to 204.8 kS/s/ch.
UP-ORION-100-500
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 500 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-500).
UP-ORION-100-1000
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 1000 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-1000).
UP-ORION-1616-3216
Upgrade the standard 16-channel A/D card from 16 to 32 simultaneously sampled channels (converts from ORION-1616-100 to
ORION-3216-100). The max. sample rate remains at 100 kS/s/ch.
DN-ORION-AD16-1000-16
Replaces the standard A/D card from ORION-1616-100 to AD16-1000-16, which provides:
Single ADC multiplexed 16-bit A/D card, 1000 kS/s aggregate max. sample rate (62.5 kS/s/ch max sample rate when all 16 analog
channels are recording), 8 TTL digital I/O lines (compatible with DS-7 ALARMS), 2 basic counter inputs.
Note: this card is not compatible with any UP-ORION series options.
Note: if CAN BUS interfaces are desired with this A/D card, please order the PCI-CAN2 card and DS- OPT-CAN software option.
Additional 0.5 panels that can be installed with the 1.5U-panel-MDAQ-BNC only:
0.5U-DA2-BNC
0.5U-AMFLEX-POWER-4
0.5U-DA4-BNC
0.5U-AMFLEX-POWER-8
0.5U-DA8-BNC
0.5U-CLAMP-DC-POWER-4
0.5U-CLAMP-DC-POWER-8
30
Dewetron PRODUCT SELECTION GUIDE
NEXT, please list the signal conditioners that you would like to have:
There are too many possibilities to list them all here. Please see the separate signal conditioner pages, and select the models that you desire, and their quantities:
DAQ modules
300 kHz bandwidth modules: DAQP-HV high voltage, DAQP-LV low voltage, DAQP-STG strain/universal
50 kHz bandwidth modules: DAQP-ACC-A accels (IEPE), DAQP-CHARGE-A accels (charge)
3 kHz bandwidth modules: DAQP-MULTI (bridge/universal, DAQP-THERM universal thermocouple
HSI modules
2 MHz bandwidth modules: HSI-HV high voltage, HSI-LV low voltage
1 MHz bandwidth modules: HSI-STG strain/universal
PAD modules
PAD-TH8-P 8-ch thermocouple module, PAD-V8-P 8-ch voltage module
MDAQ-SUB amps
300 kHz bandwidth modules: MDAQ-SUB-V200-BNC 8 channel voltage, MDAQ-SUB-ACC(-A) 8 channel accel (IEPE)
30 kHz bandwidth modules: MDAQ-SUB-STG 8 channel strain/universal, MDAQ-SUB-BRIDGE 8 channel bridge/universal
MSI adapters
For -STG-D/BRIDGE-D amps: MSI-BR-V-200 voltage, MSI-BR-ACC accel (IEPE), MSI-BR-CHA accel (charge), MSI-BR-RTD temperature (RTD), MSI-BR-TH-J(-K, -T, -C) temperature (thermocouple)
NEXT, please choose any HARDWARE upgrades that you would like (factory installed, DIFFICULT or IMPOSSIBLE TO ADD LATER):
ORION-SYNC
Synchronization option for instruments with ORION cards, allows synchronization of PC based instruments or ADC Racks for PCI, all
systems must have ORION-xx16 cards. Includes 2 m CAT-5E sync-cable, max. length of the sync-cable can be 50 m, this option is
required for each unit which needs synchronization
HDD-SATA-1TB
Adds a 1 TB (1000 GB) standard S-ATA HDD inside the chassis
SYSTEM-SSD-64
Additional internal 64 GB flash disk for Windows and DS7, the removable hard disk remains
HDD-600-SSD-32
Upgrade to 32 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
HDD-600-SSD-64
Upgrade to 64 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
HDD-600-SSD-128
Upgrade to 128 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
RAM-2048-3072
Upgrade the standard 2 GB RAM to 3 GB RAM>
NEXT, please choose any SOFTWARE upgrades that you would like (factory installed, BUT CAN BE ADDED LATER):
DS-UP-SE-PROF
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 16 channels of A/D are installed)
DS-UP-SE-DSA
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 64 channels of A/D are installed)
NEXT, please choose any ACCESSORIES that you would like:
MOB-DISP-17
Mobile high brightness 17” display with capacitive touchscreen, 1280x1024 pixels, USB touchscreen interface + DVI + VGA interfaces
Wide range DC power input (12V/24V, up to 5A), INCLUDES: #1/4-20 cup mounting points on top and sides; standard VESA100
mounting positions on the rear panel; two USB 2.0 interfaces on the side; 1 m VGA cable with DVI adapter; 2.5 m USB cable, 1 m
power cable, FGG.1B.302.CLA LEMO to banana plugs; AC/DC adapter for lab usage.
DISP-17-OPT
Accessory set for MOB-DISP-17 for use inside vehicles, includes: two high-grade suction cups; 3 m VGA cable; 3 m USB cable; 1
meter power cable (LEMO to cigarette lighter plug)
HDD-REM-BACKUP
Spare hard disk, installed inside removable drive carrier. If ordered with the system, we will clone the removable HDD onto this HDD,
so that it can be used to restore the system in the event of HDD failure.
CTR-CBL-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m
NEXT, please choose any interfaces that you would like to have installed:
ARINC or 1553
Please select from the separate lists
PCM interface
Please select from the separate lists
FG-VIDEO-4
4 input NTSC video frame grabber. Requires one PCI or PCIe slot within the system.
Time code
Please select from the separate lists
OTHER options and services available:
CAL-DAQ/MDAQ-NIST
Calibration of any single DAQ / PAD/HSI conditioner, or any MDAQ-SUB series 8-channel signal conditioning module. Includes a
NIST traceable CAL report generated by our Fluke MET/CAL system. This calibration includes the MDAQ-BASE card which holds two
MDAQ-SUB cards. The A/D card and MDAQ modules are calibrated together under our procedure. Dewetron’s USA cal lab is ANSI/
NCSL Z540-1 compliant. This calibration is valid for one year.
WARRANTY-EXT-12-24
Warranty extension, 6 % of total system price for the second year, hardware only. Must be ordered with the initial purchase order
WARRANTY-EXT-12-36
Warranty extension, 14 % of total system price for a total of 3 years, hardware only. Must be ordered with the initial purchase order
Dewetron PRODUCT SELECTION GUIDE
31
DEWE-3050 configured with up to 32 plug-in signal
conditioners (DAQ / PAD / HSI series)
DEWE-3050 with removable CAPACITIVE 17” touchscreen
DEWE-3050 series
www.dewamerica.com/Products/DEWE-3050
OVERVIEW
The DEWE-3050 is a unique model, absolutely full of
“firsts” in a DEWETRON “all in one” portable/benchtop
data acquisition instrument:
It is the only one that can hold 32 DAQ/PAD/HSI
modules. It is the only one which can hold 96 MDAQ
channels and battery power. It’s the only one with
battery power and the AC/DC adapter built inside. It’s
the only one with a capacitive touchscreen ... and it’s
the only DEWE which has a removable display!
The 5 PCI slots inside makes it possible to have a
lot of analog inputs PLUS data bus interfaces, like
ARINC, CAN, 1553, and more. It comes with a 16
channel ORION card with 100 kS/s/ch max sample
rate and DS-7-SE acquisition and analysis software.
Just choose your signal conditioning and any
upgrades / add-ons that you would like to complete
the system.
32
Dewetron PRODUCT SELECTION GUIDE
◙◙ 16 channel, 100 kS/s/ch simultaneous
sampling A/D card card inside
◙◙ Expandable to 96 FAST internal channels!
◙◙ DS-7-SE software included
◙◙ Choose from DAQ, PAD, HSI, MDAQ
and MPAD series signal conditioners in
countless combinations
◙◙ Two removable HDDs - one for data and
one for the OS and applications
◙◙ Removable TOUCHSCREEN display
◙◙ CAPACITIVE touchscreen supports multitouch applications
◙◙ 17” display, high resolution
◙◙ Keyboard stores behind the display when
not in use
◙◙ Battery power - runs 2-3 hours without any
external power connected
◙◙ Ruggedized construction, MIL-STD, ENSTD, and more
◙◙ Made in USA
◙◙ Full year warranty
Applications
◙◙
General purpose data acquisition
◙◙
Field service and field test applications
◙◙
Energy test
◙◙ Vehicle test
◙◙ Aircraft tests
◙◙
Railcar test
◙◙
Noise & vibration
◙◙ All kinds of trouble-shooting
◙◙
Every kind of mechanical and structural test
Unprecented channel counts
The DEWE-3050 is the only “all in one” Dewetron
model that can be configured with 32 slots for any
of our plug-in modules in the DAQ, PAD, and HSI
series.
If you prefer MDAQ conditioning, we can configure
the rear panel with up to 96 channels (12 x 8
channel MDAQ-SUB conditioners).
A combination of 16 plug-in and up to 64 MDAQ is
also easy to do!
No other Dewetron “all in one” system can be
configured in so many ways.
DEWE-3050 configured with 16 plug-in signal conditioners (DAQ / PAD / HSI
series) plus 32 MDAQ series channels. There is still room for 32 more MDAQ
channels - or other function PANELS
battery and AC power standard
The DEWE-3050 is the only Dewetron instrument that
has direct AC power input AND our hot-swappable
battery power technology. No external AC/DC adapter
is needed with the DEWE-3050.
If power is lost for whatever reason, the system keeps
running without interruption, instantly switching from
AC to battery power, and back again, as needed.
Even if you don’t need battery power, what a great
UPS our battery system makes.
Dewetron PRODUCT SELECTION GUIDE
33
DEWE-3050 configuration guide
To complete your DEWE-3050, you just need to choose the signal conditioners that you want. There are two
basic choices: plug-in DAQ/HSI modules, or factory installed MDAQ conditioners. Choose plug-in modules
when you need single channel modularity and ISOLATION. Choose MDAQ conditioners when differential
inputs are OK, and you want as many channels as possible on the mainframe.
The DEWE-3050 can accept a huge number and variety of signal conditioners on its rear panel - choose the
ones that you want and we’ll do the rest.
Please refer to the graphic here to see what can be installed on the rear panel.
Additional function panels are shown on the next page.
2.5U-PANEL-RACK16
Accepts up to 16 of our plugin DAQ and PAD series signal conditioning modules.
(Compatible also with all HSI modules, except that it limits their bandwidth to 300 kHz)
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
1
3
2.5U-PANEL-RACK16-HSI
Accepts up to 16 of our plugin HSI series signal conditioning modules. Also compatible
with most DAQ and PAD series modules (not compatible with DAQP-CHARGE-A and
DAQP-FREQ-A and other very old DAQ modules).
1
2
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
5
We can install zero, one, or two of the above PANELS for DAQ/PAD/HSI modules onto
the rear panel of the DEWE-3050. See the yellow outlines of where they will be located.
When one 2.0U-PANEL-RACK-16 / HSI is installed, there are still four positions for
MDAQ conditioners (up to 64 channels). See blue outlines.
When two 2.0U-PANEL-RACK16 / HSI are installed, there are no spaces available left
for MDAQ conditioners.
34
Dewetron PRODUCT SELECTION GUIDE
2.0U-PANEL-MDAQ
Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type, for
16 total differential input channels.
If no RACK16’s are installed up to 6 of these MDAQ PANELS can be installed, for a
total of 96 channels. If one RACK16 is installed, up to 4 of these MDAQ PANELS can be
installed, for up to 64 channels.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
1.5U-PANEL-MDAQ-BNC
Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only, for 16
total differential input channels.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
2
4
Note: BNC only panels are oly 1.5U high, leaving a 0.5U space underneath for additioanl
function panels. See the next pages for the complete list.
6
Several additional 1U and 2U PANELS are also available for other functions. See the next
pages for a complete list.
Unfilled space on the rear panel will be filled with modular blank panels, leaving your
DEWE-3050 ready for future upgrades.
Dewetron PRODUCT SELECTION GUIDE
35
DEWE-3050 more function panels
Here are the additional FUNCTION PANELS that are available for your DEWE-3050:
0.5U function panels
0.5U-DA2-BNC
0.5U panel with BNC connectors, supporting two analog
outputs.
0.5U-DA4-BNC
0.5U panel with BNC connectors, supporting four analog
outputs.
0.5U-DA8-BNC
0.5U panel with BNC connectors, supporting eight analog
outputs.
0.5U-AMFLEX-POWER-4
0.5U panel with BINDER 712 connectors, 9VDC power supply for up to eight PNA-100 current sensors.
0.5U-AMFLEX-POWER-8
0.5U panel with BINDER 712 connectors, 9VDC power supply for up to eight PNA-100 current sensors.
0.5U-CLAMP-DC-POWER-4
0.5U panel with LEMO connectors, 15VDC power supply
and digital status lines for up to four PNA-CLAMP-150-DC
current sensors.
0.5U-CLAMP-DC-POWER-8
0.5U panel with LEMO connectors, 15VDC power supply
and digital status lines for up to eight PNA-CLAMP-150-DC
current sensors.
1U-DA8-BNC
1U panel with BNC connectors, supporting eight analog
outputs.
1U-DA16-BNC
1U panel with BNC connectors, supporting sixteen analog
outputs.
1.5U-ORION-DIO-PANEL-1
1.5 U panel with 8 LEMO connectors EGG.1B.307 for up to
8 counters and one DSUB-37 connector for up to 16 digital
inputs, incl. mating connectors (compatible with counter
expansion options).
1.5U-TC-PANEL-32
1.5U panel prepared for up to 32 thermocouple inputs.
Please add up to four MPAD-TH8-K and/or MPAD-TH8-T
options. Each MPAD provides 8 input channels.
1.0U and 1.5U function panels
36
Dewetron PRODUCT SELECTION GUIDE
Factory installed upgrades available at the time of ordering:
UP-ORION-CAN2
Adds two high speed CAN BUS interfaces, the DB9 connectors, and the software option inside DS-7.
UP-ORION-CTR8
Upgrades the digital inputs to 8 TTL digital inputs protected
up to 25 VDC, and 8 counter/encoder inputs with programmable threshold (0-40VDC) and -35 to 60V range, AC/DC
coupling. Includes DB37 connector and mate.
UP-ORION-16-22
Upgrade the A/D card to 22-bit resolution with anti-aliasing
filtering, with 100 kS/s/ch max sample rate.
UP-ORION-16-24
Upgrade the A/D card to 24-bit resolution with anti-aliasing
filtering, with 200 kS/s/ch max sample rate.
UP-ORION-100-500
Upgrade the A/D card to 500 kS/s/ch max sample rate.
UP-ORION-100-1000
Upgrade the A/D card to 1000 kS/s/ch max sample rate.
DN-ORION-AD16-1000-16
Downgrade the A/D card to multiplexed 16-bit card with
1MS/s/ aggregate sample rate, 2 simple counters, and 8
TTL digital I/O lines.
ORION-SYNC
Installs a SYNC interface and in/out RJ45 connectors for
multi-system synchronization
3210-DC-POWER
Upgrades the power system to run from a wider DC range:6
to 30 VDC max. (instead of 18-24 VDC max).
RAM-2048-3072
Upgrades the computer RAM from 2 GB to 3 GB
RAM-2048-4096
Upgrades the computer RAM from 2 GB to 4 GB
HDD-SDD-32
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 32 GB size
HDD-SDD-64
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 64 GB size
HDD-SDD-128
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 128 GB size
HDD-SDD-256
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 256 GB size
There are other options and upgrades available - please consult your DEWETRON
representative for the latest information, and for pricing.
The right side panel door provides access to the batteries, which
can be hot-swapped during operation. Compatible with SIdeHAND2
batteries (four are included).
Dewetron PRODUCT SELECTION GUIDE
37
DEWE-3050 expansion guide
Expansion via analog cable
A very popular way of expanding the analog
inputs is to install more ORION cards into
the instrument and connect external signal
conditioning amplifiers via analog cables. Each
DEWE-3050 instrument has two spare PCI slots
which can be used to install additional ORION
cards. Select a suitable external DEWE-30 or
DEWE-31 series signal conditioning rack, the
required amplifiers and directly connect the
analog outputs to the ORION cards by analog
signal cables.
DEWE-ORION card
in main system
AN
A LO
PO
WE
ALS
G SIGN
PP
R SU
LY
AC (optional DC)
power supply
DEWE-31-12
Expansion chassis
DEWE-30-8
DEWE-30-16
DEWE-30-32
DEWE-31-16
DEWE-31-32
Amplifier slots
8
16
32
--
--
--
--
8 or 16
8, 16, 24 or 32
MDAQ channels
--
A/D converter
(Connects to the A/D card in the main system - there is no A/D converter inside any DEWE-30 or DEWE-31 chassis)
Power supply (standard)
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
DC from the mainframe or via
AC/DC adapter
120/230 VAC 50/60 Hz
Dimensions (WxDxH)
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
435 x 223 x 245 mm
16.1 x 13/4 x 7.9 in
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
Weight
4 kg (9 lbs)
7 kg (15 lbs)
1.6 kg (3.5 lbs)
4 kg (9 lbs)
Expansion via PCI bridge
The PCI expansion is an alternative especially if high channel count is
needed. When using an expansion only one PCI slot is occupied in the
DEWE-3050 instrument by a PCI-HOST-CARD. The DEWE-50, DEWE-51
and DEWE-52 ADC racks can be connected by a 1m PCI cable. The
ORION cards are installed inside the DEWE-5x unit and you simply
have to select the suitable signal amplifiers for your needs.
AC (optional DC)
power supply
Important notice: The DEWE-3050 and the DEWE-5x must be equipped
with ORION-SYNC option.
DEWE-3200
PCI H
OST
SY N C
User tip: with an additional ECARD-34 or 54 the DEWE-5x also can
be used as an independent system in combination with a laptop
computer.
DEWE-52-PCI-3216
Expansion chassis
DEWE-50-PCI-32
DEWE-50-PCI-64
DEWE-51-PCI-32
DEWE-51-PCI-128
DEWE-52-PCI-3216
Amplifier slots
32
64
--
--
16
MDAQ channels
--
--
Up to 64
Up to 128
Up to 32
ORION card slots
3
7
7
13
7
Power supply (standard)
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
Dimensions (WxDxH)
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in.
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
408 x 287 x 267 mm
16.1 x 11.3 x 10.5 in
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
Weight
10 kg (22 lbs)
15 kg (33 lbs)
6 kg (13 lbs)
9 kg (20 lbs)
9 kg (20 lbs)
38
Dewetron PRODUCT SELECTION GUIDE
Specifications
Expansion via Ethernet
The NET expansion is a fantastic way to
combine two or more DEWE instruments to
one multichannel system. Each instrument
must have installed hardware option ORIONSYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First
is a simple cable connection for distances up
to 200 m, second one is GPS- or IRIG-CLOCK
which is useful for long distances when a
cable connection is not possible. DS-OPTNET software offers full remote setup, online
data transfer up to the limit of the network
connection and offline data transfer between
the instruments.
User tip: The NET expansion also distributes
the data processing load among multiple
computers, each of which can store data at full
speed.
Specification
DEWE-3050
Slots for DAQ/PAD/HSI modules
32 with two 2.0U-PANEL-RACK-16‘s or -HSI‘s
MDAQ-SUB positions
12, via six 2.0U-PANEL-MDAQ‘s (or 1.5U-PANEL-MDAQ-BNC‘s (96 total
analog channels)
Main system
Total PCI slots
5 x full length PCI slots
Hard disk
2 x removable HDDs (500 GB for data, 100 GB for the OS)
Data throughput to disk
50 MB/s typical; faster rates available with the additional of an internal
RAID controller and/or additional drives
Power supply
Hot-swappable batteries, operates from 18~24 VDC. Includes DPS-2410
external AC/DC power adapter for recharging the batteries and operating
the system from AC mains.
Display
17” SXGA display, 1280 x 1024 px, with CAPACITIVE touchscreen
Processor
Intel i7 CPU, on a standard industrial grade ATX mainboard
RAM
4 GB
Ethernet
2 x Gb ethernet interfaces
USB
Four x USB 2.0 interfaces
RS232 serial interface
One serial interface (DB9 connector)
Optical drive
External only due to shock & vibe compliance (option OPT-CDR)
Operating system
Microsoft Windows7 32-bit included
Dimensions (W x D x H)
425 x 340 x 191 mm (16.7 x 13.4 x 7.5 in.)
Weight
10 kg typical (22 lbs) without batteries
Environmental specifications
Operating temperature
0 to 50°C (-20°C when pre-warmed )
Humdity
10 to 80% non-condensing, 5 to 95% relative humidity
Vibration
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock
MIL-STD-810F, EN 60068-2-27
Data acquisition specifications
DEWE-3050
SYNC
DEWE-3050
ETHERNE
T
Standard A/D card specifications:
100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100)
Upgrades to faster cards, and higher resolution cards available
Available A/D card upgrades:
UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing
UP-ORION-16-22: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing
UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch
UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch
Data acquisition software:
DS-7-SE is included as standard
Software upgrades available:
To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS
Analog inputs:
16, according to the installed DAQ, PAD, HSI, or MDAQ signal conditioners
Signal conditioning available:
Isolated/differential conditioners for low voltage, high voltage, strain,
bridge, pressure, thermocouples, RTDs, IEPE, charge
EPAD interface:
Standard LEMO 4-pin connector, right side panel
Computer upgrades
N/A
Hard disk drive upgrade:
Add an internal drive, or increase the size of the removable drive, or convert one or both removable drives to solid state drives
Filtering upgrades:
DAQ/HSI modules have filters built-in
MDAQ-FILT options available for MDAQ systems
Popular interfaces
0.000 ms
GPS-CLOCK
DEWE-3050
RAM upgrades:
SYNC
CAN BUS interfaces:
UP-ORION-CAN2 adds 2 high-speed synchronous CAN BUS interfaces on
DB9 connectors, and DS-OPT-CAN software option
Time code interface:
Adds an internal IRIG or GPS time code interface (does not require a PCI
slot)
VIDEO-FG-4
Adds a four channel VIDEO INPUT PCI card to the system. Four BNCs
for analog NTSC video input on the right side panel, allowing four video
streams to be recorded in sync with the data
ARINC-429
Several different interface cards are available with various numbers of
ARINC 429 transmit and receive channels
MIL-STD-1553
Several different interface cards are available with various numbers of MILSTD-1553 transmit and receive channels
Rear panel conditioner positions:
Plug-in module positions:
Up to 32 modules via 2.0U-PANEL-RACK16 or -HSI options
Differential conditioner positions:
Up to 12 MDAQ-SUB conditioners (96 channels) via 2.0U-PANEL-MDAQ or
1.5U-PANEL-MDAQ-BNC options
PANEL spaces
Differential conditioner positions:
External channel expansion
Low-speed channel expansion:
Up to 16 EPAD2 modules can be connected to the EPAD connector, adding
up to 128 channels of low-speed thermocouple, voltage, RTD, and current
inputs, in blocks of eight channels
Expansion via analog cable:
Up to 96 total dynamic analog input channels (with three 32-channel A/D
cards installed inside the DEWE-3210, and external DEWE-30/31 chassis
connected.
Expansion via PCI bridge:
Up to 256 total dynamic analog input channels (with PCI bridge card
installed inside the DEWE-3210, and external DEWE-50/51 chassis connected.
Expansion via ethernet:
Up to 2000 total dynamic analog input channels (with SYNC option for local
connections, or IRIG/GPS sync for remote connections, and multiple remote DEWE systems synchronized via DS-OPT-NET software option.
GPS-CLOCK
DEWE-3050
SYNC
ETHER
NET
Dewetron PRODUCT SELECTION GUIDE
39
DEWE-3050 ordering guide
Please use the table below to configure your DEWE-3050 system. From this ordering guide, your DEWETRON representative
can create a detailed price quote for you.
First, please choose your basic model:
DEWE-3050
Benchtop / portable battery-powered data acquisition system
16-bit resolution, simultaneous sampling, 100 kS/s per channel
8 synchronous TTL digital I/Os
2 synchronous TTL counter / encoder or 8 TTL digital inputs
6.0U panel space available for signal conditioners
Choose from plugin DAQ / PAD / HSI series conditioning modules or
MDAQ differential signal conditioning inputs (16 channels) or a combination
2 free PCI slots (3 full length slots are inside, one is used by the A/D card) EPAD2 connector for optional EPAD2 modules. DS-7-SE
software is included
NEXT, please choose the SIGNAL CONDITIONING PANEL(S) that you need (factory installed, See previous pages for possibilities):
2.5U-PANEL-RACK16
2.5U Card cage for up to 16 DAQ / HSI / PAD module slots, 300 kHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
2.5U-PANEL-RACK16-HSI
2.5U Card cage for up to 16 HSI / DAQ / PAD module slots, 2 MHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
Not compatible with the DAQP-CHARGE-A, DAQP-FREQ-A, and certain older DAQ modules
2.0U-PANEL-MDAQ-DSUB
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where either or both of have 9-pin DSUB connectors.
Please order your choice of MDAQ-SUB-XX-D conditioners separately (2 required).
1.5U-PANEL-MDAQ-BNC
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where both have BNC connectors. Please order your
choice of MDAQ-SUB-XX-BNC conditioners separately (2 required).
ADDITIONAL AVAILABLE connector panels
0.5U-ORION-CNT2-LEMO
0.5 U panel with 2 LEMO connectors EGG.1B.307 connected to the 2 counters of an ORION base card, incl. mating connectors
1.5U-ORION-DIO-PANEL-1
1.5 U panel with 8 LEMO connectors EGG.1B.307 for up to 8 counters and 1 DSUB-37 connector for up to 16 digital inputs, incl. mating connectors, requires UP-ORION-CNT
0.5U-AMPFLEX-POWER-8
0.5 U panel with 8 Binder 712 connectors, 9 V Power supply for PNA-A100 current transducers
0.5U-CLAMP-DC-POWER-4
0.5 U panel with 4 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
0.5U-CLAMP-DC-POWER-8
0.5 U panel with 8 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
1.5U-TC-PANEL-32
1.5U panel prepared for up to 32 thermocouple inputs; please add one to four MPAD-TH8-x options
MPAD-TH8-K
Adds 8 internal thermocouple inputs type K to the 1.5U-TC-PANEL-32, sampling rate 12 Hz
MPAD-TH8-T
Adds 8 internal thermocouple inputs type T to the 1.5U-TC-PANEL-32, sampling rate 12 Hz
0.5U-DA2-BNC
0.5 U panel with 2 BNC connectors connected to the 2 analog outputs of an AD16-1000-16-OUT2 card
0.5U-DA4-BNC
0.5 U panel with 4 BNC connectors connected to the 4 analog outputs of a DA4-1000-16 card
0.5U-DA8-BNC
0.5 U panel with 4 BNC connectors connected to the 8 analog outputs of a DA8-1000-16 card
please choose any A/D card upgrades that you require (factory installed only):
UP-ORION-16-22
Upgrade the standard 16-channel A/D card from 16-bit resolution to 22-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1622-100). The max. sample rate remains at 100 kS/s/ch.
UP-ORION-16-24
Upgrade the standard 16-channel A/D card from 16-bit resolution to 24-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1624-200). The max. sample rate increases to 204.8 kS/s/ch.
UP-ORION-100-500
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 500 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-500).
UP-ORION-100-1000
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 1000 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-1000).
UP-ORION-1616-3216
Upgrade the standard 16-channel A/D card from 16 to 32 simultaneously sampled channels (converts from ORION-1616-100 to
ORION-3216-100). The max. sample rate remains at 100 kS/s/ch.
DN-ORION-AD16-1000-16
Replaces the standard A/D card from ORION-1616-100 to AD16-1000-16, which provides:
Single ADC multiplexed 16-bit A/D card, 1000 kS/s aggregate max. sample rate (62.5 kS/s/ch max sample rate when all 16 analog
channels are recording), 8 TTL digital I/O lines (compatible with DS-7 ALARMS), 2 basic counter inputs.
Note: this card is not compatible with any UP-ORION series options.
Note: if CAN BUS interfaces are desired with this A/D card, please order the PCI-CAN2 card and DS- OPT-CAN software option.
More A/D cards:
Because this system can support up to three A/D cards, please see the separate price list section if you wish to add more than the
one A/D card which is included in the mainframe price. ORION and AD series A/D cards must be the same bit resolution and speed to
be used at the same time.
40
Dewetron PRODUCT SELECTION GUIDE
NEXT, please list the signal conditioners that you would like to have:
There are too many possibilities to list them all here. Please see the separate signal conditioner pages, and select the models that you desire, and their quantities:
DAQ modules
300 kHz bandwidth modules: DAQP-HV high voltage, DAQP-LV low voltage, DAQP-STG strain/universal
50 kHz bandwidth modules: DAQP-ACC-A accels (IEPE), DAQP-CHARGE-A accels (charge)
3 kHz bandwidth modules: DAQP-MULTI (bridge/universal, DAQP-THERM universal thermocouple
HSI modules
2 MHz bandwidth modules: HSI-HV high voltage, HSI-LV low voltage
1 MHz bandwidth modules: HSI-STG strain/universal
PAD modules
PAD-TH8-P 8-ch thermocouple module, PAD-V8-P 8-ch voltage module
MDAQ-SUB amps
300 kHz bandwidth modules: MDAQ-SUB-V200-BNC 8 channel voltage, MDAQ-SUB-ACC(-A) 8 channel accel (IEPE)
30 kHz bandwidth modules: MDAQ-SUB-STG 8 channel strain/universal, MDAQ-SUB-BRIDGE 8 channel bridge/universal
MSI adapters
For -STG-D/BRIDGE-D amps: MSI-BR-V-200 voltage, MSI-BR-ACC accel (IEPE), MSI-BR-CHA accel (charge), MSI-BR-RTD temperature (RTD), MSI-BR-TH-J(-K, -T, -C) temperature (thermocouple)
NEXT, please choose any HARDWARE upgrades that you would like (factory installed, DIFFICULT or IMPOSSIBLE TO ADD LATER):
ORION-SYNC
Synchronization option for instruments with ORION cards, allows synchronization of PC based instruments or ADC Racks for PCI, all
systems must have ORION-xx16 cards. Includes 2 m CAT-5E sync-cable, max. length of the sync-cable can be 50 m, this option is
required for each unit which needs synchronization
HDD-SATA-1TB
Adds a 1 TB (1000 GB) standard S-ATA HDD inside the chassis
SYSTEM-SSD-64
Additional internal 64 GB flash disk for Windows and DS7, the removable hard disk remains
HDD-600-SSD-32
Upgrade to 32 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
HDD-600-SSD-64
Upgrade to 64 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
HDD-600-SSD-128
Upgrade to 128 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
RAM-2048-3072
Upgrade the standard 2 GB RAM to 3 GB RAM>
NEXT, please choose any SOFTWARE upgrades that you would like (factory installed, BUT CAN BE ADDED LATER):
DS-UP-SE-PROF
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 16 channels of A/D are installed)
DS-UP-SE-DSA
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 64 channels of A/D are installed)
NEXT, please choose any ACCESSORIES that you would like:
MOB-DISP-17
Mobile high brightness 17” display with capacitive touchscreen, 1280x1024 pixels, USB touchscreen interface + DVI + VGA interfaces
Wide range DC power input (12V/24V, up to 5A), INCLUDES: #1/4-20 cup mounting points on top and sides; standard VESA100
mounting positions on the rear panel; two USB 2.0 interfaces on the side; 1 m VGA cable with DVI adapter; 2.5 m USB cable, 1 m
power cable, FGG.1B.302.CLA LEMO to banana plugs; AC/DC adapter for lab usage.
DISP-17-OPT
Accessory set for MOB-DISP-17 for use inside vehicles, includes: two high-grade suction cups; 3 m VGA cable; 3 m USB cable; 1
meter power cable (LEMO to cigarette lighter plug)
HDD-REM-BACKUP
Spare hard disk, installed inside removable drive carrier. If ordered with the system, we will clone the removable HDD onto this HDD,
so that it can be used to restore the system in the event of HDD failure.
CTR-CBL-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m
NEXT, please choose any interfaces that you would like to have installed:
ARINC or 1553
Please select from the separate lists
PCM interface
Please select from the separate lists
FG-VIDEO-4
4 input NTSC video frame grabber. Requires one PCI or PCIe slot within the system.
Time code
Please select from the separate lists
OTHER options and services available:
CAL-DAQ/MDAQ-NIST
Calibration of any single DAQ / PAD/HSI conditioner, or any MDAQ-SUB series 8-channel signal conditioning module. Includes a
NIST traceable CAL report generated by our Fluke MET/CAL system. This calibration includes the MDAQ-BASE card which holds two
MDAQ-SUB cards. The A/D card and MDAQ modules are calibrated together under our procedure. Dewetron’s USA cal lab is ANSI/
NCSL Z540-1 compliant. This calibration is valid for one year.
WARRANTY-EXT-12-24
Warranty extension, 6 % of total system price for the second year, hardware only. Must be ordered with the initial purchase order
WARRANTY-EXT-12-36
Warranty extension, 14 % of total system price for a total of 3 years, hardware only. Must be ordered with the initial purchase order
Dewetron PRODUCT SELECTION GUIDE
41
DEWE-3040-RM rear/side view, with modular
rear panel
DEWE-3040 -RM with 19” wide display
DEWE-3040-RM series
www.dewamerica.com/Products/DEWE-3050-RM
OVERVIEW
The DEWE-3040-RM is our flagship RACKMOUNTING data acquisition instrument. It has a
16-channel A/D card installed already, with 100 kS/s/
ch simultaneous sampling and 16-bit resolution. Our
DS-7 software is also included.
Simply choose your plugin modules or factory installed
MDAQ signal conditioners (or a combination) in order
to complete your system. You can also add more A/D
cards and expand the system up to 96 channels.
The rear panel supports up to 16 DAQ/PAD/HSI plugin signal conditioners, or up to 96 channels of MDAQ
conditioners ... or a combination 16 DAQ/PAD/HSI
plus 64 MDAQ conditioners.
There are always eight digital I/O lines, plus two
counter inputs compatible with tachometers and
encoders are standard, of course. You can also add
interfaces to record bus data from ARINC, 1553, PCM,
CAN...as well as VIDEO, and more.
42
Dewetron PRODUCT SELECTION GUIDE
◙◙ 16 channel, 100 kS/s/ch simultaneous
sampling A/D card card inside
◙◙ Expandable to 96 FAST internal channels!
◙◙ DS-7-SE software included
◙◙ Choose from DAQ, PAD, HSI, MDAQ
and MPAD series signal conditioners in
countless combinations
◙◙ 500 GB removable HDD on front-panel
◙◙ Built-in 19” W-I-D-E display
◙◙ 19” display, 1280x1024 resolution
◙◙ Keyboard and touchpad built-in
◙◙ Keyboard slides out when needed
◙◙ Ruggedized construction, MIL-STD, ENSTD, and more
◙◙ Made in USA
◙◙ Full year warranty
Applications
◙◙
Flight test ground station recording
◙◙ Test cell data acquisition
◙◙
Energy test (with DAQ/HSI modules)
◙◙ Vehicle test cells
◙◙ Aircraft test cells
◙◙
Wind tunnel test cells
◙◙
Production test cells
◙◙ Voltage/current/power monitoring
◙◙
Every kind of mechanical and structural test
Flexible Rear Panel
The DEWE-3040-RM can be configured with 16
slots for any of our plug-in modules in the DAQ,
PAD, and HSI series, plus up to 64 channels of
MDAQ conditioners.
Or, if you only need MDAQs, we can configure the
rear panel with up to 96 channels (12 x 8 channel
MDAQ-SUB conditioners). There are six 2.0U
PANEL positions, so you can also add MPAD blocks
of 32 thermocouples, and a wide variety of other
interfaces and connectors to the rear panel.
Made for the 19” rack cabinet
There is no “rack kit” needed, because the DEWE3040-RM has rack mounting ears already built in
as an integral part of the chassis. Slides are also
included, and the tapped mounting holes are already
prepared for you.
There are no commonly accessed connections on
either side panel - everything is located on the front or
the back for maximum rack-mounting convenience.
Dewetron PRODUCT SELECTION GUIDE
43
DEWE-3040-RM configuration guide
To complete your DEWE-3040-RM, you just need to choose the signal conditioners that you want. There are
two basic choices: plug-in DAQ/PAD/HSI modules, or factory installed MDAQ conditioners. Choose plug-in
modules when you want the ultimate in modularity and/or SIGNAL ISOLATION. Choose MDAQ conditioners
when differential inputs are sufficient, and/or you want as many channels as possible on the mainframe.
The DEWE-3040-RM can accept a huge number and variety of signal conditioners on its rear panel - choose
the ones that you want and we’ll do the rest.
Please refer to the graphic here to see what can be installed on the rear panel.
Additional function panels are shown on the next page.
2.5U-PANEL-RACK16
Accepts up to 16 of our plugin DAQ and PAD series signal conditioning modules.
(Compatible also with all HSI modules, except that it limits their bandwidth to 300 kHz)
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
1
1
1
3
2.5U-PANEL-RACK16-HSI
Accepts up to 16 of our plugin HSI series signal conditioning modules. Also compatible
with most DAQ and PAD series modules (not compatible with DAQP-CHARGE-A and
DAQP-FREQ-A and other very old DAQ modules).
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
We can install either one (or neither) of the above PANELS for DAQ/PAD/HSI modules
onto the rear panel of the DEWE-3040-RM. See the yellow outline of where it will be
located.
When one 2.0U-PANEL-RACK-16 / HSI is installed, there are still four positions for
MDAQ conditioners (up to 64 channels). See blue outlines.
When a 2.0U-PANEL-RACK16 / HSI is NOT installed, there are SIX 2.0U spaces
available left for MDAQ and other PANELS!
44
Dewetron PRODUCT SELECTION GUIDE
5
2.0U-PANEL-MDAQ
Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type, for
16 total differential input channels.
If no RACK16’s are installed up to 6 of these MDAQ PANELS can be installed, for a
total of 96 channels. If one RACK16 is installed, up to 4 of these MDAQ PANELS can be
installed, for up to 64 channels.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
1.5U-PANEL-MDAQ-BNC
2
Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only, for 16
total differential input channels.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
4
Note: BNC only panels are oly 1.5U high, leaving a 0.5U space underneath for additioanl
function panels. See the next pages for the complete list.
6
Several additional 1U and 2U PANELS are also available for other functions. See the next
pages for a complete list.
Unfilled space on the rear panel will be filled with modular blank panels, leaving your
DEWE-3040-RM ready for future upgrades.
Dewetron PRODUCT SELECTION GUIDE
45
DEWE-3040-RM function panels
Here are the additional FUNCTION PANELS that are available for your DEWE-3040-RM:
0.5U function panels
0.5U-DA2-BNC
0.5U panel with BNC connectors, supporting two analog
outputs.
0.5U-DA4-BNC
0.5U panel with BNC connectors, supporting four analog
outputs.
0.5U-DA8-BNC
0.5U panel with BNC connectors, supporting eight analog
outputs.
0.5U-AMFLEX-POWER-4
0.5U panel with BINDER 712 connectors, 9VDC power supply for up to eight PNA-100 current sensors.
0.5U-AMFLEX-POWER-8
0.5U panel with BINDER 712 connectors, 9VDC power supply for up to eight PNA-100 current sensors.
0.5U-CLAMP-DC-POWER-4
0.5U panel with LEMO connectors, 15VDC power supply
and digital status lines for up to four PNA-CLAMP-150-DC
current sensors.
0.5U-CLAMP-DC-POWER-8
0.5U panel with LEMO connectors, 15VDC power supply
and digital status lines for up to eight PNA-CLAMP-150-DC
current sensors.
1U-DA8-BNC
1U panel with BNC connectors, supporting eight analog
outputs.
1U-DA16-BNC
1U panel with BNC connectors, supporting sixteen analog
outputs.
1.5U-ORION-DIO-PANEL-1
1.5 U panel with 8 LEMO connectors EGG.1B.307 for up to
8 counters and one DSUB-37 connector for up to 16 digital
inputs, incl. mating connectors (compatible with counter
expansion options).
1.5U-TC-PANEL-32
1.5U panel prepared for up to 32 thermocouple inputs.
Please add up to four MPAD-TH8-K and/or MPAD-TH8-T
options. Each MPAD provides 8 input channels.
1.0U and 1.5U function panels
46
Dewetron PRODUCT SELECTION GUIDE
FACTORY INSTALLED upgrades available at the time of ordering:
UP-ORION-CAN2
Adds two high speed CAN BUS interfaces, the DB9 connectors, and the software option inside DS-7.
UP-ORION-CTR8
Upgrades the digital inputs to 8 TTL digital inputs protected
up to 25 VDC, and 8 counter/encoder inputs with programmable threshold (0-40VDC) and -35 to 60V range, AC/DC
coupling. Includes DB37 connector and mate.
UP-ORION-16-22
Upgrade the A/D card to 22-bit resolution with anti-aliasing
filtering, with 100 kS/s/ch max sample rate.
UP-ORION-16-24
Upgrade the A/D card to 24-bit resolution with anti-aliasing
filtering, with 200 kS/s/ch max sample rate.
UP-ORION-100-500
Upgrade the A/D card to 500 kS/s/ch max sample rate.
UP-ORION-100-1000
Upgrade the A/D card to 1000 kS/s/ch max sample rate.
DN-ORION-AD16-1000-16
Downgrade the A/D card to multiplexed 16-bit card with
1MS/s/ aggregate sample rate, 2 simple counters, and 8
TTL digital I/O lines.
ORION-SYNC
Installs a SYNC interface and in/out RJ45 connectors for
multi-system synchronization
3210-DC-POWER
Upgrades the power system to run from a wider DC range:6
to 30 VDC max. (instead of 18-24 VDC max).
RAM-2048-3072
Upgrades the computer RAM from 2 GB to 3 GB
RAM-2048-4096
Upgrades the computer RAM from 2 GB to 4 GB
HDD-SDD-32
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 32 GB size
HDD-SDD-64
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 64 GB size
HDD-SDD-128
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 128 GB size
HDD-SDD-256
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 256 GB size
There are other options and upgrades available - please consult your DEWETRON
representative for the latest information, and for pricing.
Dewetron PRODUCT SELECTION GUIDE
47
DEWE-3040-RM expansion guide
Expansion via analog cable
A very popular way of expanding the analog
inputs is to install more ORION cards into
the instrument and connect external signal
conditioning amplifiers via analog cables. Each
DEWE-3040-RM instrument has two spare PCI
slots which can be used to install additional
ORION cards. Select a suitable external DEWE30 or DEWE-31 series signal conditioning rack,
the required amplifiers and directly connect the
analog outputs to the ORION cards by analog
signal cables.
DEWE-ORION card
in main system
AN
A LO
PO
WE
ALS
G SIGN
PP
R SU
LY
AC (optional DC)
power supply
DEWE-31-12
Expansion chassis
DEWE-30-8
DEWE-30-16
DEWE-30-32
DEWE-31-16
DEWE-31-32
Amplifier slots
8
16
32
--
--
--
--
8 or 16
8, 16, 24 or 32
MDAQ channels
--
A/D converter
(Connects to the A/D card in the main system - there is no A/D converter inside any DEWE-30 or DEWE-31 chassis)
Power supply (standard)
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
DC from the mainframe or via
AC/DC adapter
120/230 VAC 50/60 Hz
Dimensions (WxDxH)
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
435 x 223 x 245 mm
16.1 x 13/4 x 7.9 in
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
Weight
4 kg (9 lbs)
7 kg (15 lbs)
1.6 kg (3.5 lbs)
4 kg (9 lbs)
Expansion via PCI bridge
The PCI expansion is an alternative especially if high channel count
is needed. When using an expansion only one PCI slot is occupied in
the DEWE-3040-RM instrument by a PCI-HOST-CARD. The DEWE-50,
DEWE-51 and DEWE-52 ADC racks can be connected by a 1m PCI
cable. The ORION cards are installed inside the DEWE-5x unit and you
simply have to select the suitable signal amplifiers for your needs.
AC (optional DC)
power supply
Important notice: The DEWE-3040-RM and the DEWE-5x must be
equipped with ORION-SYNC option.
DEWE-3200
PCI H
OST
SY N C
User tip: with an additional ECARD-34 or 54 the DEWE-5x also can
be used as an independent system in combination with a laptop
computer.
DEWE-52-PCI-3216
Expansion chassis
DEWE-50-PCI-32
DEWE-50-PCI-64
DEWE-51-PCI-32
DEWE-51-PCI-128
DEWE-52-PCI-3216
Amplifier slots
32
64
--
--
16
MDAQ channels
--
--
Up to 64
Up to 128
Up to 32
ORION card slots
3
7
7
13
7
Power supply (standard)
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
120/230 VAC 50/60 Hz
Dimensions (WxDxH)
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in.
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
408 x 287 x 267 mm
16.1 x 11.3 x 10.5 in
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
Weight
10 kg (22 lbs)
15 kg (33 lbs)
6 kg (13 lbs)
9 kg (20 lbs)
9 kg (20 lbs)
48
Dewetron PRODUCT SELECTION GUIDE
Specifications
Expansion via Ethernet
The NET expansion is a fantastic way to
combine two or more DEWE instruments to
one multichannel system. Each instrument
must have installed hardware option ORIONSYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First
is a simple cable connection for distances up
to 200 m, second one is GPS- or IRIG-CLOCK
which is useful for long distances when a
cable connection is not possible. DS-OPTNET software offers full remote setup, online
data transfer up to the limit of the network
connection and offline data transfer between
the instruments.
User tip: The NET expansion also distributes
the data processing load among multiple
computers, each of which can store data at full
speed.
Specification
DEWE-3040-RM
Slots for DAQ/PAD/HSI modules
16 with 2.0U-PANEL-RACK-16‘s or -HSI‘s
MDAQ-SUB positions
12, via six 2.0U-PANEL-MDAQ‘s (or 1.5U-PANEL-MDAQ-BNC‘s), for 96
total analog input channels
Main system
Total PCI slots
Two full length PCI and two full length PCIe slots
Hard disk
500 GB standard removable drive (optional solid state drive)
Data throughput to disk
50 MB/s typical; faster rates available with the additional of an internal
RAID controller and/or additional drives
Power supply
120/240 VAC 50/60 Hz AC mains, including IEC power cable.
Display
19” WXGA display, 1400x900 px, with optional touchscreen
Processor
Intel Core2Duo 2.0 GHz CPU, on a ATX mainboard
RAM
2 GB (expandable to 4 GB)
Ethernet
2 x Gb ethernet interfaces
USB
Four x USB 2.0 interfaces
RS232 serial interface
One serial interface (DB9 connector)
Optical drive
DVD+-CD-RW drive built-in. CD burning capability included
Operating system
Microsoft Windows7 32-bit included
Dimensions (W x D x H)
425 x 340 x 191 mm (16.7 x 13.4 x 7.5 in.)
Weight
10 kg typical (22 lbs)
Environmental specifications
Operating temperature
0 to 50°C (-20°C when pre-warmed)
Humdity
10 to 80% non-condensing, 5 to 95% relative humidity
Vibration
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock
MIL-STD-810F, EN 60068-2-27
Data acquisition specifications
DEWE-3040-RM
DEWE-3040-RM
SYNC
ETHERNE
T
Standard A/D card specifications:
100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100)
Upgrades to faster cards, and higher resolution cards available
Available A/D card upgrades:
UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing
UP-ORION-16-22: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing
UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch
UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch
Data acquisition software:
DS-7-SE is included as standard
Software upgrades available:
To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS
Analog inputs:
16, according to the installed DAQ, PAD, HSI, or MDAQ signal conditioners
Signal conditioning available:
Isolated/differential conditioners for low voltage, high voltage, strain,
bridge, pressure, thermocouples, RTDs, IEPE, charge
EPAD interface:
Standard LEMO 4-pin connector, right side panel
Computer upgrades
RAM upgrades:
Increase from 2 to 3 GB or 4 GB
Hard disk drive upgrade:
Add an internal drive, or increase the size of the removable drive, or convert the removable drive to a solid state drive
Filtering upgrades:
DAQ/HSI modules have filters built-in
MDAQ-FILT options available for MDAQ systems
Popular interfaces
0.000 ms
CAN BUS interfaces:
UP-ORION-CAN2 adds 2 high-speed synchronous CAN BUS interfaces on
DB9 connectors, and DS-OPT-CAN software option
Time code interface:
Adds an internal IRIG or GPS time code interface (does not require a PCI
slot)
VIDEO-FG-4
Adds a four channel VIDEO INPUT PCI card to the system. Four BNCs
for analog NTSC video input on the right side panel, allowing four video
streams to be recorded in sync with the data
ARINC-429
Several different interface cards are available with various numbers of
ARINC 429 transmit and receive channels
MIL-STD-1553
Several different interface cards are available with various numbers of MILSTD-1553 transmit and receive channels
Rear panel conditioner positions:
GPS-CLOCK
DEWE-3040-RM
Plug-in module positions:
Up to 16 modules via 2.0U-PANEL-RACK16 or -HSI options
Differential conditioner positions:
Up to 12 MDAQ-SUB conditioners (96 channels) via 2.0U-PANEL-MDAQ or
1.5U-PANEL-MDAQ-BNC options
PANEL spaces
Differential conditioner positions:
SYNC
External channel expansion
GPS-CLOCK
DEWE-3040-RM
SYNC
ETHER
NET
Low-speed channel expansion:
Up to 16 EPAD2 modules can be connected to the EPAD connector, adding
up to 128 channels of low-speed thermocouple, voltage, RTD, and current
inputs, in blocks of eight channels
Expansion via analog cable:
Up to 96 total dynamic analog input channels (with three 32-channel A/D
cards installed inside the DEWE-3210, and external DEWE-30/31 chassis
connected.
Expansion via PCI bridge:
Up to 256 total dynamic analog input channels (with PCI bridge card
installed inside the DEWE-3050-RM, and external DEWE-50/51 chassis
connected.
Expansion via ethernet:
Up to 2000 total dynamic analog input channels (with SYNC option for local
connections, or IRIG/GPS sync for remote connections, and multiple remote DEWE systems synchronized via DS-OPT-NET software option.
Dewetron PRODUCT SELECTION GUIDE
49
DEWE-3040-RM ordering guide
Please use the table below to configure your DEWE-3040-RM system. From this ordering guide, your DEWETRON
representative can create a detailed price quote for you.
First, please choose your basic model:
DEWE-3040-RM
Rack-mounting AC-powered data acquisition system
16-bit resolution, simultaneous sampling, 100 kS/s per channel
8 synchronous TTL digital I/Os
2 synchronous TTL counter / encoder or 8 TTL digital inputs
6.0U panel space available for signal conditioners
Choose from plugin DAQ / PAD / HSI series conditioning modules or
MDAQ differential signal conditioning inputs (16 channels) or a combination
1 free PCI slot, 2 free PCIe slots (4 full length slots are inside, one is used by the A/D card) EPAD2 connector for optional EPAD2
modules. DS-7-SE software is included
NEXT, please choose the SIGNAL CONDITIONING PANEL(S) that you need (factory installed, See previous pages for possibilities):
2.5U-PANEL-RACK16
2.5U Card cage for up to 16 DAQ / HSI / PAD module slots, 300 kHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
2.5U-PANEL-RACK16-HSI
2.5U Card cage for up to 16 HSI / DAQ / PAD module slots, 2 MHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
Not compatible with the DAQP-CHARGE-A, DAQP-FREQ-A, and certain older DAQ modules
2.0U-PANEL-MDAQ-DSUB
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where either or both of have 9-pin DSUB connectors.
Please order your choice of MDAQ-SUB-XX-D conditioners separately (2 required).
1.5U-PANEL-MDAQ-BNC
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where both have BNC connectors. Please order your
choice of MDAQ-SUB-XX-BNC conditioners separately (2 required).
ADDITIONAL AVAILABLE connector panels
0.5U-ORION-CNT2-LEMO
0.5 U panel with 2 LEMO connectors EGG.1B.307 connected to the 2 counters of an ORION base card, incl. mating connectors
1.5U-ORION-DIO-PANEL-1
1.5 U panel with 8 LEMO connectors EGG.1B.307 for up to 8 counters and 1 DSUB-37 connector for up to 16 digital inputs, incl. mating connectors, requires UP-ORION-CNT
0.5U-AMPFLEX-POWER-8
0.5 U panel with 8 Binder 712 connectors, 9 V Power supply for PNA-A100 current transducers
0.5U-CLAMP-DC-POWER-4
0.5 U panel with 4 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
0.5U-CLAMP-DC-POWER-8
0.5 U panel with 8 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
1.5U-TC-PANEL-32
1.5U panel prepared for up to 32 thermocouple inputs; please add one to four MPAD-TH8-x options
MPAD-TH8-K
Adds 8 internal thermocouple inputs type K to the 1.5U-TC-PANEL-32, sampling rate 12 Hz
MPAD-TH8-T
Adds 8 internal thermocouple inputs type T to the 1.5U-TC-PANEL-32, sampling rate 12 Hz
0.5U-DA2-BNC
0.5 U panel with 2 BNC connectors connected to the 2 analog outputs of an AD16-1000-16-OUT2 card
0.5U-DA4-BNC
0.5 U panel with 4 BNC connectors connected to the 4 analog outputs of a DA4-1000-16 card
0.5U-DA8-BNC
0.5 U panel with 4 BNC connectors connected to the 8 analog outputs of a DA8-1000-16 card
please choose any A/D card upgrades that you require (factory installed only):
UP-ORION-16-22
Upgrade the standard 16-channel A/D card from 16-bit resolution to 22-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1622-100). The max. sample rate remains at 100 kS/s/ch.
UP-ORION-16-24
Upgrade the standard 16-channel A/D card from 16-bit resolution to 24-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1624-200). The max. sample rate increases to 204.8 kS/s/ch.
UP-ORION-100-500
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 500 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-500).
UP-ORION-100-1000
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 1000 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-1000).
UP-ORION-1616-3216
Upgrade the standard 16-channel A/D card from 16 to 32 simultaneously sampled channels (converts from ORION-1616-100 to
ORION-3216-100). The max. sample rate remains at 100 kS/s/ch.
DN-ORION-AD16-1000-16
Replaces the standard A/D card from ORION-1616-100 to AD16-1000-16, which provides:
Single ADC multiplexed 16-bit A/D card, 1000 kS/s aggregate max. sample rate (62.5 kS/s/ch max sample rate when all 16 analog
channels are recording), 8 TTL digital I/O lines (compatible with DS-7 ALARMS), 2 basic counter inputs.
Note: this card is not compatible with any UP-ORION series options.
Note: if CAN BUS interfaces are desired with this A/D card, please order the PCI-CAN2 card and DS- OPT-CAN software option.
More A/D cards:
Because this system can support up to three A/D cards, please see the separate price list section if you wish to add more than the
one A/D card which is included in the mainframe price. ORION and AD series A/D cards must be the same bit resolution and speed to
be used at the same time.
50
Dewetron PRODUCT SELECTION GUIDE
NEXT, please list the signal conditioners that you would like to have:
There are too many possibilities to list them all here. Please see the separate signal conditioner pages, and select the models that you desire, and their quantities:
DAQ modules
300 kHz bandwidth modules: DAQP-HV high voltage, DAQP-LV low voltage, DAQP-STG strain/universal
50 kHz bandwidth modules: DAQP-ACC-A accels (IEPE), DAQP-CHARGE-A accels (charge)
3 kHz bandwidth modules: DAQP-MULTI (bridge/universal, DAQP-THERM universal thermocouple
HSI modules
2 MHz bandwidth modules: HSI-HV high voltage, HSI-LV low voltage
1 MHz bandwidth modules: HSI-STG strain/universal
PAD modules
PAD-TH8-P 8-ch thermocouple module, PAD-V8-P 8-ch voltage module
MDAQ-SUB amps
300 kHz bandwidth modules: MDAQ-SUB-V200-BNC 8 channel voltage, MDAQ-SUB-ACC(-A) 8 channel accel (IEPE)
30 kHz bandwidth modules: MDAQ-SUB-STG 8 channel strain/universal, MDAQ-SUB-BRIDGE 8 channel bridge/universal
MSI adapters
For -STG-D/BRIDGE-D amps: MSI-BR-V-200 voltage, MSI-BR-ACC accel (IEPE), MSI-BR-CHA accel (charge), MSI-BR-RTD temperature (RTD), MSI-BR-TH-J(-K, -T, -C) temperature (thermocouple)
NEXT, please choose any HARDWARE upgrades that you would like (factory installed, DIFFICULT or IMPOSSIBLE TO ADD LATER):
ORION-SYNC
Synchronization option for instruments with ORION cards, allows synchronization of PC based instruments or ADC Racks for PCI, all
systems must have ORION-xx16 cards. Includes 2 m CAT-5E sync-cable, max. length of the sync-cable can be 50 m, this option is
required for each unit which needs synchronization
HDD-SATA-1TB
Adds a 1 TB (1000 GB) standard S-ATA HDD inside the chassis
SYSTEM-SSD-64
Additional internal 64 GB flash disk for Windows and DS7, the removable hard disk remains
HDD-600-SSD-32
Upgrade to 32 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
HDD-600-SSD-64
Upgrade to 64 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
HDD-600-SSD-128
Upgrade to 128 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data
throughput 20 MB/s
RAM-2048-3072
Upgrade the standard 2 GB RAM to 3 GB RAM>
NEXT, please choose any SOFTWARE upgrades that you would like (factory installed, BUT CAN BE ADDED LATER):
DS-UP-SE-PROF
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 16 channels of A/D are installed)
DS-UP-SE-DSA
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 64 channels of A/D are installed)
NEXT, please choose any ACCESSORIES that you would like:
MOB-DISP-17
Mobile high brightness 17” display with capacitive touchscreen, 1280x1024 pixels, USB touchscreen interface + DVI + VGA interfaces
Wide range DC power input (12V/24V, up to 5A), INCLUDES: #1/4-20 cup mounting points on top and sides; standard VESA100
mounting positions on the rear panel; two USB 2.0 interfaces on the side; 1 m VGA cable with DVI adapter; 2.5 m USB cable, 1 m
power cable, FGG.1B.302.CLA LEMO to banana plugs; AC/DC adapter for lab usage.
DISP-17-OPT
Accessory set for MOB-DISP-17 for use inside vehicles, includes: two high-grade suction cups; 3 m VGA cable; 3 m USB cable; 1
meter power cable (LEMO to cigarette lighter plug)
HDD-REM-BACKUP
Spare hard disk, installed inside removable drive carrier. If ordered with the system, we will clone the removable HDD onto this HDD,
so that it can be used to restore the system in the event of HDD failure.
CTR-CBL-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m
NEXT, please choose any interfaces that you would like to have installed:
ARINC or 1553
Please select from the separate lists
PCM interface
Please select from the separate lists
FG-VIDEO-4
4 input NTSC video frame grabber. Requires one PCI or PCIe slot within the system.
Time code
Please select from the separate lists
OTHER options and services available:
CAL-DAQ/MDAQ-NIST
Calibration of any single DAQ / PAD/HSI conditioner, or any MDAQ-SUB series 8-channel signal conditioning module. Includes a
NIST traceable CAL report generated by our Fluke MET/CAL system. This calibration includes the MDAQ-BASE card which holds two
MDAQ-SUB cards. The A/D card and MDAQ modules are calibrated together under our procedure. Dewetron’s USA cal lab is ANSI/
NCSL Z540-1 compliant. This calibration is valid for one year.
WARRANTY-EXT-12-24
Warranty extension, 6 % of total system price for the second year, hardware only. Must be ordered with the initial purchase order
WARRANTY-EXT-12-36
Warranty extension, 14 % of total system price for a total of 3 years, hardware only. Must be ordered with the initial purchase order
Dewetron PRODUCT SELECTION GUIDE
51
With the battery option, you can
hot-swap the batteries when needed,
keeping the system running indefinitely.
STG models are compatible with all
MSI-BR adapters, for maximum sensor
compatibility
DEWE-214 with optional battery pack
(battery pack fastens to the bottom of
the chassis)
DEWE-214 series
www.dewamerica.com/Products/DEWE-214
OVERVIEW
The DEWE-214 is our top of the line IN VEHICLE
testing instrument. It’s small size and power system
were specifically designed for mobile/vehicle
applications. It’s quite at home in your car, truck,
motorcycle, tank, military vehicle, train, boat, NASCAR
vehicle...
The analog inputs are extremely flexible, and the A/D
system behind them is top-notch: 24-bit resolution
for the highest dynamic range, 200 kS/s/ch sampling
(max), simultaneous sampling, brick wall anti-aliasing
filtering, and more.
The DEWE-214 also features two high speed CAN
bus interfaces supporting CAN and J1939 protocols
(OBD II optional). There are also digital I/O lines and
two counter inputs compatible with tachometers and
encoders.
Choose which conditioner you want, then what speed
of GPS sensor you would like: 1, 20, or 100 Hz.
52
Dewetron PRODUCT SELECTION GUIDE
◙◙ 8 high performance analog channels, 200
kS/s/ch simultaneous sampling
◙◙ Anti-aliasing filtering standard
◙◙ 24-bit resolution for highest dynamic range
◙◙ DS-7-SE software included
◙◙ Available in two basic versions with three
choice of GPS speeds
◙◙ 32 GB SLC solid state HDD (upgradable to
64, 128, 256 GB)
◙◙ Optional MOBILE display
◙◙ Keyboard and mouse included
◙◙ Wide range DC power input 8~30 VDC
◙◙ Battery power option - runs 2-3 hours
without any external power connected
◙◙ Batteries are hot-swappable - even during
measurement
◙◙ Ruggedized construction, MIL-STD, ENSTD, and more
◙◙ Full year warranty
Applications
◙◙
In-vehicle data acquisition
◙◙
Cars, trucks, motorcycles, trains
◙◙
Race cards - NASCAR, Formula 1, Indy...
◙◙ Aircraft, boats and ships
◙◙
Military vehicle test
◙◙
Field service and field test applications
◙◙
Noise & vibration
◙◙ All kinds of trouble-shooting
◙◙
Every kind of mechanical and structural test
◙◙
Every kind of MOBILE and VEHICLE test
MADE FOR THE ROAD
The DEWE-214 was designed specifically for invehicle testing. It starts with the wide-range DC
power input (8~30VDC), and its amazingly small
size and convenient form factor. Anchor points on
the sides make it easy to strap down in a moving
vehicle.
And the performance cuts no corners: 24-bit
resolution for incredible dynamic range. The built-in
GPS, including 20 and 100 Hz receivers is ideal for
dynamic testing, like brake and accel testing, ride
and handling, driveability, and more.
Small but essential features like these
tie-down “anchor” points, are standard
in the DEWE-214.
MOBILE display option
The MOB-DISP-17 (option) is a great add-on for
any portable DEWE system, especially for invehicle applications. This is a ruggedized display
with a capacitive touchscreen (supports multi-touch
software!) that’s brighter than ever.
And we built three USB 2.0 interfaces into it, so you
can put the 214 in the trunk, and mount the MOB
display up front. Use the USBs to connect memory
sticks, or your keyboard, etc. Get the optional kit for
the suction cups and longer cables for in-vehicle
usage.
Dewetron PRODUCT SELECTION GUIDE
53
DEWE-214 configuration
DEWE-214-STG model with 1, 20, or 100 Hz GPS
The DEWE-214-STG model features our most FLEXIBLE analog inputs, based on the MDAQ-STG conditioner. It can
natively handle any kind of bridge or strain gage, with completion for half and quarter bridge sensors and various wiring
methods, amp and sensor balance, and so much more. You can input ±10V directly. Using our MSI-BR series adapters
you can also input IEPE accels and mics, charge sensors, thermocouples (J, K, T, C), RTD sensors (Pt100, 200, 500,
1000), voltages up to ±200V. We also offer ADAP series adapters for 4-20 mA sensors and simple BNC adapters.
Choose the GPS version you want, with 1, 20 or 100 Hz sensor.
The STG series is the more flexible of the two basic DEWE-214 models, and you can upgrade it to 16 channels!
DEWE-214-STG with optional channel expansion from 8 to 16 channels
(the standard model has the left-most 8 channels installed)
DEWE-214-ACC model with 1, 20, or 100 Hz GPS
Choose the DEWE-214-ACC model if you will be doing mostly IEPE inputs for noise, shock and vibration testing. There
are eight 80 kHz bandwidth inputs with TEDS support, which provide the constant current excitation needed by IEPE
accelerometers and microphones. You can input ±10V, ±2V, ±0.5 or ±0.1V directly. All of the analog inputs are on
convenient BNC connectors. Maximum analog sample rate is 204.8 kS/s/ch. Anti-aliasing filtering is standard, of course.
Choose the GPS version you want, with 1, 20 or 100 Hz sensor.
Both DEWE-214 models include two synchronous SUPER counters, which are ideal for tachs, tape, and RPM sensors as
well as encoders – and offer adjustable trigger levels, and input ranges beyond TTL. In addition, there are 8 TTL digital
inputs (ideal for measuring simple switch closures and "discrete" signals) and 8 TTL digital outputs (great for alarm
outputs, a standard software feature). All digital lines are available on the standard DB37 connector on the front panel.
LEMO connectors for the counters are available as an option (ORION-CNT2-LEMO).
54
Dewetron PRODUCT SELECTION GUIDE
Expansion via Ethernet
The NET expansion is a fantastic way to
combine two or more DEWE instruments to
one multichannel system. Each instrument
must have installed hardware option ORIONSYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First
is a simple cable connection for distances up
to 200 m, second one is GPS- or IRIG-CLOCK
which is useful for long distances when a
cable connection is not possible. DS-OPTNET software offers full remote setup, online
data transfer up to the limit of the network
connection and offline data transfer between
the instruments.
DEWE-214
DEWE-214
SYNC
ETHERNE
T
DEWE-214
User tip: The NET expansion also distributes
the data processing load among multiple
computers, each of which can store data at full
speed.
GPS
(20Hz or 100Hz)
DEWE-214
Specifications
Specification
DEWE-214 STG
DEWE-214 ACC
Analog input channels
8 (upgrade to 16 channels optional)
8
Expandable to 16 channels
Yes (option 214-STG-08-16 adds 8 more STG channels, with the same specifications as the first 8 channels)
N/A
Digital I/O lines (TTL)
8 in / 8 out (inputs are TTL/CMOS level with pull-up with 100 kΩ). Low range: -0.7 to 0.8V; High range: 2 to 5V
Counter inputs
2 synchronous advanced counter / encoders
Counter specifications
32-bit resolution, 80 MHz clock (40 MHz max input frequency) 5 MHz bandwidth, 1 MΩ input impedance (5pF), trigger level adjustable 0-40V, ±100V over voltage input
protection, AC/DC input coupling (1 Hz HP filter with AC coupling), differential and symmetrical inputs, common voltage range: -35 to 50V
Trigger input
1 included, TTL Schmidt trigger, pull-up with 100 kΩ. Low range: -0.7 to 2V; High range: 3 to 5V
Signal conditioning
8 FLEXIBLE strain gage / voltage inputs, TEDS compatible
8 FLEXIBLE IEPE / voltage inputs, TEDS compatible
Measuring modes:
Full bridge, 1⁄2 bridge, 1⁄4 bridge 120 Ω, 1⁄4 bridge 350 Ω or ±10V voltage
Full bridge sensors 120 Ω to 10 kΩ
Internal completion for 1⁄2 bridge and 1⁄4 bridge sensors
Internal 50 kΩ and 100 kΩ shunt resistors
Voltage: ±0.125 V, 0.25 V, 0.5 V, 1 V, 1.25 V, 2.5 V, 5 V, 10 V
IEPE: 0.5, 1, 2, 4, 5, 10, 20, 40
Single ended or differential
DC or AC coupled (3 Hz standard, on request down to 0.1 Hz)
Analog connector
DB9
BNC
Max sample rate
204.8 kS/s/ch
204.8 kS/s/ch
Analog bandwidth (-3 dB)
30 kHz
80 kHz
Bit resolution
24-bit
24-bit
Anti-aliasing filtering
Automatic
Automatic
MSI compatible
Yes
No
MSI adapters available
MSI-BR-ACC supports IEPE accels and mics; MSI-BR-CHA-50 supports dynamic
charge sensors; MSI-BR-V200 supports voltages up to ±200V; MSI-BR-RTD supports Pt100/Pt200/Pt500/Pt1000 RTDs; MSI-BR-TH supports J, T, K, or C thermocouples
N/A
Slow channel expansion
Via one or more EPAD2 and CPAD2 series isolated 8-channel signal conditioners. See EPAD2/CPAD2 section for the full range available
CAN BUS interfaces
2 high-speed CAN BUS interfaces standard, on DB9 connectors. Supports CAN 2.0B and J1939 protocols (OBD-II support requires software option).
GPS sensor
1 Hz standard (20 Hz and 100 Hz dynamic GPS sensor optional)
1 Hz standard (20 Hz and 100 Hz dynamic GPS sensor optional)
GPS sensor
Speed, position, direction (20/100 Hz GPS options also output distance, acceleration, Z height and acceleration, UTC time reference)
Speed, position, direction (20/100 Hz GPS options also output distance, acceleration, Z height and acceleration, UTC time reference)
VIDEO input
One USB camera can be used to add VIDEO to your data recordings. Compatible with all DirectX standard webcams.
Software included
DS-7-SE with CAN option. DS-7-SE is a complete data acquisition and analysis software package including unlimited setup file creation, on-line and off-line math channels
(including filtering, integration, and more), with scope, recorder, FFT, GPS map, VIDEO, analog and digital meter displays, and much more.
Main system
Hard disk
32 GB SLC solid state HDD, upgradable to 64 GB, 128 GB, or 256 GB. Data throughput to disk: typ. 40 MB/s continuous
Power supply
8 ~ 30 VDC wide range DC power input, including external AC/DC adapter, and DC cable with cigarette lighter plug
Display
Optional MOB-DISP-17 (1280x1024 px, high brightness, capacitive touchscreen (USB interface)
Processor
Intel® Core2Duo 2 GHz
RAM
2 GB (expandable to 3 GB)
Interfaces built-in
2 x 1 Gb ethernet; WLAN (WIFI) including attachable antenna, 4 x USB 2.0, LEMO connector for Dewetron EPAD2 series modules
Operating system
Microsoft Windows7 32-bit
Dimensions (W x D x H)
317 x 252 x 92 mm (12.5 x 9.9 x 3.6 in.)
Weight
Typ. 5 kg (11 lb.)
Operating temperature
0 to 50°C (-20°C when unit is pre-warmed and not powered off at temperatures below 0°C)
Humidity
10 to 80% non-condensing; 5 to 95% relative humidity
Shock and Vibration
Shock: EN 60068-2-27 ; Vibration: EN 60068-2-6, EN 60721-3-2 class 2M2, better than MIL-STD-810F (for shock and vibration)
Dewetron PRODUCT SELECTION GUIDE
55
DEWE-214 interfaces
Two High-speed CAN BUS interfaces
Both DEWE-214 models feature two high-speed CAN
BUS interfaces compatible with the CAN 2.0B and
J1939 protocols. In the software you can import DBC
setup files, or create your CAN setup manually if you
like. There is a convenient "listen" function that scans
the bus and identifies any messages that are coming
across, and adds them to the list. It's easy to configure
the channels that are contained within each message by
bit range, name, scaling factor, and engineering units.
Everything gets saved into the setup file.
Configuring the channels within each message couldn’t be much easier.
CAN channels are just like any others in your Dewetron system. You can display
them, record them, use them in MATH, trigger from them... no restrictions.
OBD II interface capabilities
If you want to read the OBD II messages, there is a
software option for that. Simply configure either or both
CAN ports for OBD II, and the software will do the rest.
The software even includes an automatic listing of the
basic codes, already set up for you.
When OBD II has been configured for a CAN interface, these standard channels
are set up for you automatically. Just turn on the ones you want to record.
Use CAN for channel expansion, too
Dewetron CAN BUS interfaces can also be used
for connecting CAN based sensors, including our
own CPAD2 series 8 channel signal conditioners for
thermocouples, voltages, currents, and RTDs. See the
CONDITIONERS section for a full listing of the CPAD2
modules that are available today. We even put power on
two of the unused pins of the connector, so that we can
directly power our CPAD2 modules. This conveniently
eliminates the need to provide power to them separately.
But virtually any standard CAN output device can be
used with our CAN interfacess, including non-Dewetron
brand sensors and signal conditioners.
56
Dewetron PRODUCT SELECTION GUIDE
Typical Display:
Where other systems show you some
squiggly lines and maybe some
numbers, that’s where we start.
You can show and record VIDEO (see
below for details).
You can show and record CAN BUS
data (see previous page for details).
You can show and record GPS
data, both digitally as well as in a
graphical GPS track. Bring in one or
more satellite or map images and
position them behind the track (this
is easy to do).
You can show and record additional
data from our EPAD2 and CPAD2
conditioners, as well as third-party
CAN based sensors.
You can show and record SERIAL and
ETHERNET data from a wide variety
of third party devices (just add a
software plugin).
Then create as many screens as you
like in our software, and set them up
just the way that you like.
That’s data acquisition like no one
ever did it before.
That’s Dewetron.
WEB CAM / Gig-E CAM connection
Dewetron famously invented the use of common web
cameras with data acquisition systems nearly 10 years
ago. You can connect nearly every standard DirectX
video camera in the world (one maximum) to your
DEWE-214 and start recording video in sync with your
other data right away.
Or, for better performance, choose our DEWE-CAMGIGE-50 camera, and ethernet GIG-E camera!
VIDEO adds incredible context to your data acquisition.
AboveL DEWE-CAM-GIGE-50
Above: typical WEB cam
Inertial sensors for dynamic testing
We offer two inertial sensors for a wide variety of vehicle
test applications. There is a relativelyy inexpensive
XSENS MTi-G sensor that you can hold in your hand, for
basic applications.
But for high-end applications such as CAPS, driveability,
brake testing, etc. we offer the ADMA system from
GeneSys, completely integrated with your DEWE system.
See the SENSORS section for further details about both
inertial sensors.
Dewetron PRODUCT SELECTION GUIDE
57
MDAQ series modules
Multi-channel, non-isolated
Factory installed
DAQ and HSI series modules
Single channel, isolated
User exchangable
Signal Conditioners
http://www.dewamerica.com/Products/Conditioners
OVERVIEW
Dewetron offers a wide variety of signal conditioners
for analog sensors, signals, and transducers. We
have several series in order to better address the
requirements of many applications, from power to
electrical testing, and on to dynamic signal analysis.
Here is a brief overview of each type and how it is
best applied:
DAQ Modules - AC/DC signals, single channel, user exchangable
at any time, HIGH ISOLATION, high bandwidth (most models)
HSI Modules - identical form factor to DAQ series modules,
except providing MHz level bandwidth, for high speed applications
MDAQ Modules - AC/DC signals, multi-channel, non-isolated,
high bandwidth, DENSE/LOW COST/CHANNEL
PAD Modules - DC signals (DCV, temperature), multi-channel,
isolated, low bandwidth, LOW COST/CHANNEL
EPAD2 Modules - external version of PAD modules
CPAD2 Modules - like EPAD except CAN BUS output
58
Dewetron PRODUCT SELECTION GUIDE
◙◙ DAQ, PAD, EPAD2, and CPAD2 modules
are user-exchangeable, even with the power
on
◙◙ DAQ/MDAQ modules output conditioned +/5V to Dewetron A/D cards for digitization
◙◙ PAD/EPAD2/CPAD2 modules output
digitized signals via serial/USB/CAN bus into
the Dewetron computer
◙◙ All Dewetron platforms support multiple
module types in each chassis!
◙◙ Some platforms support ALL module types!
◙◙ Industrial grade constuction
◙◙ CE Mark, ISO9001
◙◙ Full year warranty
PAD series modules
Multi-channel, isolated, slow signals
Plug into Dewetron systems
HSI series modules
Single channel, isolated, FAST signals (1 MHz)
Plug into Dewetron systems
Identical form factor to DAQ series modules.
T h e R i g h t To o l . . .
...for the right job. DAQ, HSI and MDAQ modules
are made for AC/dynamic signals (of course they
handle DC as well). With high dynamic performance
and superb accuracy specifications, there are a
wide variety of modules for every sensor. New is our
DAQP-STG UNIVERSAL SIGNAL CONDITIONER,
which can do just about everything either directly
using our MSI multi-sensor interfaces: strain,
pressure, mV, 200 V, RTD, IEPE, charge sensors, and
more. There is a similar MDAQ version of this module,
too.
EPAD2 series modules
Multi-channel, isolated, slow signals
Serial output
HSI modules are a whole new series with 1~2 MHz
bandwidth, with the same form factor as DAQ and
PAD series modules. The first three HSI modules
are the STG (universal), the HV (high voltage) and
LV (low voltage). These are an amazing combination
of performance, size, price, isolation... only from
Dewetron.
PAD series plug into the same slots as DAQ modules,
but are made for slow signals, usually temperature.
There are also two external versions: EPAD2 (serial/
USB output) and CPAD2 (CAN bus output).
The best news is that most Dewetron systems are
compatible with all these kinds of signal conditioners,
so you can create a system with exactly what you
need today - and add more later, as required!
CPAD2 series modules
Multi-channel, isolated, slow signals
CAN output
Dewetron PRODUCT SELECTION GUIDE
59
Dewetron SIGNAL CONDITIONERS - DAQ Series...
Module
Input type
Ranges
TEDS
Bandwidth (BW)
Filters (LP / HP)
ISOLATION (ISO)
Over-voltage Protection (OP)
High Voltage Measurement
DAQP-HV
V
High voltage
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.8 kVrms (lineto-line)
High voltage
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
N/A
BW: 700 kHz
ISO: 1.8 kVrms (lineto-line)
High voltage
±10, ±40, ±100, ±200, ±400, ±1000 V
N/A
BW: 20/30 kHz
LP: 10, 100, Hz
1, 2, 20/30 kHz
ISO: 1.5 kVrms
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: up to 1 kVrms
(with banana jacks)
OP: 350 VDC
DAQP-HV-S3
V
DAQP-DMM
V
Low/Medium Voltage & Current Measurement
DAQP-LV
V
DAQP-V
V
Voltage, current with
external shunt or current
sensor
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10, ±25, ±50 V
IEPE via MSI-V-ACC
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10 V
PT100, Pt200, Pt500,
Pt1000, Pt2000 and resistance via MSI-V-RTD
-200 to 1000 C and 0 to 6.5 kΩ
Voltage, current with
external shunt or current
sensor
±10, ±100 mV
±1, ±5, ±10, ±50 V
N/A
BW: 50 kHz
LP: 10, 100 Hz
1, 10, 50 kHz
ISO: up to 1 kVrms
OP: ±500 VDC or 350
Vrms
Current
Note: 5Arms continuous
±0.1, ±0.3, ±1, ±3 A
±10 A peak, ±30 A peak
max 5Arms continuous current
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.4 kVrms
Current
Note: intended for 4-20
mA applications
±2, ±6, ±20 mA
±60 mA, ±200 mA, ±0.6A
max 0.6 A
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.4 kVrms
Strain gages, bridge sensors, voltages
Bridge:full, half, quarter bridge
Voltage: up to ±10 V
Pot./Ohmic sensors
Resistance/Ω: up to 10 kΩ
ISO: 350 VDC
OP: ±10 VDC
Thermocouple via MSRBR-TH series
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
J, K, T and C types
Strain gages, bridge
sensors
±1, ±2, ±5, ±10, ±20, ±50 mV/V
(@ 5 Vdc excitation)
Pot./Ohmic sensors
200 ohm to 10 kohm
N/A
ISO: 350 VDC
OP: ±50 VDC
Thermocouple via MSRBR-TH series
BW: 20 kHz
LP: 10, 100 Hz
1, 5, 20 kHz
Full range of thermocouple type
Strain gages, bridge
sensors
±0.1, ±0.2, ±0.5, ±1, ±2, ±5, ±10,
±20, ±50, ±100 mV/V
(@ 5 Vdc excitation)
Yes
BW: 200 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 200 kHz
ISO: N/A
OP: ±10 VDC
N/A
BW: dc to 2.3 kHz
LP: 10, 30, 100, 300 Hz
1 kHz
ISO: N/A
OP: ±10 VDC
DAQP-LA-SC
DAQP-LA-B
Bridge / Strain Gage Measurement
DAQP-STG
DAQP-BRIDGE-A
DAQP-BRIDGE-B
DAQP-CFB
60
Pot./Ohmic sensors
200 ohm to 10 kohm
Thermocouple via MSRBR-TH series
Full range of thermocouple type
AC bridge, strain gage,
carrier sensors
Bridge: 0.1 to 1000 mV/V
Inductive: 5 to 1000 mV/V
Inductive/ LVDT sensors
Voltage: 0.2 to 1000 mV/vrms
Dewetron PRODUCT SELECTION GUIDE
Module
Input type
Ranges
TEDS
Bandwidth (BW)
Filters (LP / HP)
ISOLATION (ISO)
Over-voltage Protection (OP)
Charge/IEPE Measurement
DAQP-ACC-A
DAQP-CHARGE-A
DAQP-CHARGE-B
IEPE sensors
±50, ±166, ±500 mV; ±1.66, ±5 V
(Gain: 1, 3, 10, 30, 100)
Yes
BW: 0.5 Hz to 300 kHz
LP: 1, 10, 100, 300 kHz
HP: 0.5 Hz, 5 Hz
N/A
IEPE and charge sensors
Note: selectable
integration and double
integration
Charge: 5, 50, 500, 5000, 50000 pC
IEPE: ±5, ±50, ±500 mV, ±5 V
(0, 20, 40, 60 dB)
N/A
BW: 0.1 Hz to 50 kHz
LP: 100 Hz; 1, 3, 10, 50
kHz
HP: 0.1 Hz, 1 Hz, 10 Hz
N/A
Charge sensors
Note: selectable time
constant for static charge
sensors
±100, ±500, ±2 000, ±10 000,
±40 000, ±200 000, ±1 000 000 pC
N/A
BW: 0.5 Hz to 100 kHz
LP: 10, 30, 100, 300 Hz;
1, 3, 10, 30, 100 kHz
HP: DC, 0.0001 Hz to
0.5 Hz
ISO: 350 VDC
Thermocouple (universal)
K, J, T, R, S, N, E, B, L, C, U type,
internal linearization, freely programmable range, internal CJC
RTD
Pt100, Pt200, Pt500, Pt1000 and
Pt2000 sensors, programmable range
(2-wire and 4-wire only)
Yes
BW: 3 kHz
LP: 3Hz, 10 Hz, 30 Hz, 100
Hz, 300 Hz, 1 kHz
Butterworth or Bessel;
2nd, 4th, 6th, or 8th order
programmable
ISO: 1000 Vrms
continuous (for input,
excitation and TEDS
interface)
ISO: ±1000 Vrms
continuous
Temperature and Universal Measurement
DAQP-MULTI
V
Voltage
10 ranges from ±5 mV to ± 5 V
Resistance
freely programmable range from 1
Ohm to 1 MOhm
Bridge (constant current)
4-wire full bridge sensors, 13 ranges
from ±0.5 to 5000 mV/mA
Thermocouple (universal)
K, J, T, R, S, N, E, B, L, C, U
freely programmable within the
maximum range of the selected thermocouple type, internal linearization,
internal CJC
N/A
BW: 3 kHz
LP: 3Hz, 10 Hz, 30 Hz, 100
Hz, 300 Hz, 1 kHz
Butterworth or Bessel;
2nd, 4th, 6th, or 8th order
(programmable)
Frequency to voltage
100, 1k, 5k, 20k, 100k and 200 kHz
ranges;
Trigger level range 0 to 130 V,
Additional TTL output (isolated pulse
output of input signal)
N/A
BW: 200 kHz
Selectable input and output
filters (range-dependent)
ISO: 350 Vrms
Analog output
1:1 output module, from 0 to ±10 V
Accuracy ±0.05 %
Connector choices: banana, BNC, or
9-pin DSUB connector
N/A
BW: 400 Hz
ISO: CMV output to
input, continuous: 1500
VRMS max
DAQP-THERM
Frequency to Voltage Measurement
DAQP-FREQ-A
Output Modules
DAQN-V-OUT
OUT
Dewetron PRODUCT SELECTION GUIDE
61
Dewetron SIGNAL CONDITIONERS - HSI Series...
HSI modules are a whole new series with 1~2 MHz bandwidth, with the same form factor
as DAQ and PAD series modules. The first three HSI modules are the STG (universal), the
HV (high voltage) and LV (low voltage). You can plug them into normal DAQ slots and they
will work although with a 300 kHz max bandwidth. Or order a new system with the faster
backplane.
Module
Input type
Ranges
TEDS
Bandwidth (BW)
Filters (LP / HP)
ISOLATION (ISO)
Over-voltage Protection (OP)
High Voltage Measurement
HSI-HV
V
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
High voltage
N/A
BW: 2 MHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
1, 2 MHz
ISO: 1.8 kVrms
(line-to-line)
N/A
BW: 2 MHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
1, 2 MHz
ISO: up to 1 kVrms
(with banana jacks)
OP: 350 VDC
BW: 2 MHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
1 MHz
ISO: 350 VDC
OP: ±10 VDC
Low/Medium Voltage & Current Measurement
HSI-LV
V
Voltage, current with
external shunt or current
sensor
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10, ±25, ±50 V
IEPE via MSI-V-ACC
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10 V
PT100, Pt200, Pt500,
Pt1000, Pt2000 and resistance via MSI-V-RTD
-200 to 1000 C and 0 to 6.5 kΩ
Strain gages, bridge sensors, voltages
Bridge: full, half, quarter
Voltage: Up to ±10V
Pot./Ohmic sensors
Resistance/Ω: up to 10 kΩ
Thermocouple via MSRBR-TH series
J, K, T and C types
Bridge / Strain Gage Measurement
HSI-STG
ADDitional adapters
ADAP series adapters for a variety of applications
ADAP-BRIDGE-1/4-120
ADAP-BRIDGE-1/4-350
ADAP-BRIDGE-1/2-120
ADAP-BRIDGE-1/2-350
120 Ω, 1/4 bridge
completion adapter, for
MDAQ-SUB-BRIDGE-D,
DEWE-43- DEWE-101
350 Ω, 1/4 bridge
completion adapter, for
MDAQ-SUB-BRIDGE-D,
DEWE-43- DEWE-101
120 Ω, 1/2 bridge
completion adapter, for
MDAQ-SUB-BRIDGE-D,
DEWE-43- DEWE-101
350 Ω, 1/2 bridge
completion adapter, for
MDAQ-SUB-BRIDGE-D,
DEWE-43- DEWE-101
ADAP-MDAQ-BNCF
ADAP-SHUNT-50-BNC
ADAP-CONN-DSUB-9
ADAP-XLR-BNC
Images are figurative and may not exactly match the actual appearance
62
Dewetron PRODUCT SELECTION GUIDE
BNC to DB9 adapter for
MDAQ with DB9 connectors, DEWE-43, DEWE-101,
DEWE-3143...
50 Ω shunt adapter for 4-20
mA measurements (0.1%,
1 W). BNC input connector
and DB9 output connector.
DB9 connector with convenient screw terminals inside
for easy hook up without
soldering. (Shown opened
here)
Adapter from mic XLR
connector to BNC output
connector, includes short
BNC cable
ADAP-DAQ-BNCF
ADAP-SHUNT-100-BNC
BNC to DB9 adapter for
DAQ and HSI modules with
DB9 connectors, such as
DAQP-LV-D, DAQP-V-D,
HSI-LV-D
100 Ω shunt adapter for 0-5
A measurements (0.1%, 1
W). BNC input connector
and DB9 output connector.
ADAP-BAN-BNC
Banana jack inputs to BNC
output connector
ADAP-1032-BNC
10-32 Microdot input to
BNC output, compatible with DAQP-ACC-A,
MSI-BR-ACC, MDAQ-SUBACC, DAQP-CHARGE...
MSI multi sensor interfaces...
MSI multisensor inputs for HSI, DAQ, and MDAQ modules
HSI-STG
DAQP-STG
MDAQ-SUBSTG-D
MDAQ-SUBBRIDGE-D
DAQPBRIDGE-A
DAQPBRIDGE-B
HSI-LV-D
DAQP-LV-D
MDAQ-SUBV-200-D
Constant current (IEPE) adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Excitation current 4 mA at 21V. high-pass filter 1.5 Hz, BNC input connector. Bandwidth, ranges, and isolation are determined by the module that it is plugged into.
Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
MSI-BR-ACC
MSI-V-ACC
Yes
Yes
--
--
--
--
--
--
--
--
--
--
--
--
Yes
Yes
Yes
±200 V adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Differential input configuration, BNC input connector. Bandwidth, ranges, and isolation are determined by the module that it is plugged into. Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
MSI-BR-V-200
Yes
Yes
Yes
Yes
--
--
--
--
--
RTD adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Compatible with Pt100, Pt200, Pt500, Pt1000, Pt2000 via 2, 3 and 4-wire connection methods.5-pin BINDER series 710 input connector (mate included). Bandwidth, ranges, and isolation are determined by the module that it is plugged into. Automatic MSI identification in DS-7 software (TEDS cannot then be used for
sensor identification when an MSI is used).
MSI-BR-RTD
MSI-V-RTD
Yes
Yes
Yes
Yes
--
--
--
--
--
--
--
--
--
--
--
Yes
Yes
Yes
CHARGE sensor adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Dynamic input configuration, BNC input connector. Bandwidth, ranges, and isolation are determined by the module that it is plugged into. Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
MSI-BR-CHA-50
Yes
Yes
Yes
Yes
--
--
--
--
--
Thermocouple sensor adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Available in types J, K, and T (color coded). Standard mini T/C input connector jack (female). Bandwidth, ranges, and isolation are determined by the module that
it is plugged into. Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
MSI-BR-TH-K
Yes
Yes
Yes
Yes
Yes*
--
--
--
--
MSI-BR-TH-J
Yes
Yes
Yes
Yes
Yes*
--
--
--
--
MSI-BR-TH-T
Yes
Yes
Yes
Yes
Yes*
--
--
--
--
* Automatic MSI identification is not supported by the DAQP-BRIDGE-A.
CAN BUS ISOLATORS and adapters
Adapters FOR CAN BUS
ADAP-CAN-HI-LOW
ADAP-CAN-HI-SW
Adapter from high speed
CAN (ISO 11898-2) to low
speed CAN (ISO 11898-3)
Adapter from high speed
CAN (ISO 11898-2) to
single wire CAN (SAE
J2411)
ADAP-CAN-ISO
Isolator for CAN bus interfaces (any type)
Images are figurative and may not exactly match the actual appearance
Dewetron PRODUCT SELECTION GUIDE
63
Dewetron SIGNAL CONDITIONERS - MDAQ Series...
Anatomy of an MDAQ module...
MDAQ modules are factory installed within your
Dewetron system. From the outside you see
only the input connectors. But inside, there is a
BASE card which can hold any two 8-channel
MDAQ-SUB modules on one side, and any
MDAQ-FILT filter card on the other side. The
result is a system which can be configured to
suit a wide variety of applications.
TOP: MDAQ-SUB modules (2)
MIDDLE: MDAQ-BASE module
BOTTOM: MDAQ-FILT (optional)
SUB Modules for MDAQ-BASE-x
Module
# CH Input type
MDAQ-SUB-STG-D
Connector: DB-9
8
V
MDAQ-SUB-BRIDGE-D
Connector: DB-9
8
V
MDAQ-SUB-V-200-D
Connector: DB-9
8
V
MDAQ-SUB-V-200-BNC
Connector: BNC
8
* Strain-gage (Full-, half and quarterbridge, incl. shunt calibration)
for strain gage application:
* Voltage up to ±10 V:
* ICP via MSI-BR-ACC:
* Voltage up to 200 V via MSI-BR-V-200:
* Thermocouple via MSI-BR-TH-x:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-BR-RTD:
* Strain-gage (Full-, and half bridge)
for strain gage sensors:
* Voltage up to ±10 V:
* ICP, via MSI-BR-ACC:
* Voltage up to 200 V via MSI-BR-V-200:
* Thermocouple via MSI-BR-TH-x:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-BR-RTD:
Input ranges
14 ranges from ±0.5 to 1000 mV/V
(@ 5 VDC excitation
TEDS
Bandwidth (BW),
Excitation
Highpass filters (HP)
■
BW: 30 kHz
0 to 12 VDC
■
BW: 30 kHz
HP: 0.16 Hz
+15 VDC and
0 to 12 VDC
■
BW: 300 kHz
±15 VDC and
0 to 12 VDC
-
BW: 300 kHz
-
■
BW: 300 kHz
HP: 3.4 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz, 3.4 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz, 3.4 Hz
4 / 8 mA
15 ranges from ±2.5 mV to ±10 V
7 ranges from ±0.25 mV to ±10 V
6 ranges from ±10 to ±200 V
full range of TC type
-200 °C to 1000 °C
and 0 to 6.5 kOhm
14 ranges from ±0.5 to 1000 mV/V
(@ 5 VDC excitation
15 ranges from ±2.5 mV to ±10 V
7 ranges from ±0.25 mV to ±10 V
6 ranges from ±10 to ±200 V
full range of TC type
-200 °C to 1000 °C
and 0 to 6.5 kOhm
* Voltage up to ±200 V:
* ICP, via MSI-V-ACC:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-V-RTD:
Note:
for safety reasons, max. 120 V DC or 50 V AC
13 ranges from ±0.125 to ±200 V
7 ranges from ±0.25 mV to ±10 V
-200 °C to 1000 °C
and 0 to 6.5 kOhm
* Voltage up to ±200 V:
13 ranges from ±0.125 to ±200 V
are allowed at this connector
Note:
for safety reasons, max. 120 V DC or 50 V AC are allowed at this connector
V
MDAQ-SUB-ACC-BNC
Connector: BNC
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended or differential input and one highpass filter
3.4 Hz highpass filter for noise and shock response measurement
MDAQ-SUB-ACC-BNC-S1
0,16 Hz for structural and modal analysis, human body vibration measurement
(rest same as MDAQ-SUB-ACC-BNC)
MDAQ-SUB-ACC-A-BNC
Connector: BNC
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended input and two HP filters
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
MDAQ-SUB-ACC-A-MD
Connector: Microdot
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended input, two HP filters and sensor failure detection
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
Option: test signal input for all channels
64
Dewetron PRODUCT SELECTION GUIDE
MDAQ-FILT OPTIONS
Filter modules for MDAQ
Module
MDAQ-AAF4-5-BU
# CH
16
Filter characteristics
Butterworth
Cut-off frequencies
100 Hz, 1, 10, 30, 100 kHz, Bypass
Order
th
4
Note:
not possible in all system configurations.
Please contact factory for details.
nd
MDAQ-FILT-5-BU
16
Butterworth
30, 100, 300 Hz, 1, 10 kHz, Bypass
2
MDAQ-FILT-5-BU-S1
16
Butterworth
100 Hz, 1, 10, 30, 100 kHz, Bypass
2
MDAQ-FILT-5-BE
16
Bessel
30, 100, 300 Hz, 1, 10 kHz, Bypass
2
MDAQ modules - available in most of the
DEWETRON multichannel systems.
The DEWE-501 can accept
up to 8 MDAQ-SUB conditioners, for 64 dynamic
input channels
Typical combination with
two SUB modules mounted
on a BASE module, and
FILTER board (optional)
nd
nd
All MDAQ boards are
equipped with highest quality components
Dewetron PRODUCT SELECTION GUIDE
65
Dewetron SIGNAL CONDITIONERS - PAD Series...
PAD
That stands for “programmable A/D” module. Although PAD modules share the form factor
of the DAQ series, they have their own ADCs on board, and output digitally via the serial bus
that is built into each slot in a Dewetron system (the same bus that is used to control the DAQ
and MDAQ modules). Our most popular PAD modules are the PAD-TH8-P, an outstanding 8
channel thermocouple module. Just plug in the breakout box of your choice - we have PADCB8 breakout boxes for types J, K, and T thermocouples, as well as RTD temperature sensors.
There are several more PAD modules, like the PAD-V8-P which provides 8 voltage inputs, and
others. If you don’t want to block an analog input in your system with a PAD module, go for
the EPAD2 or CPAD2 series EXTERNAL PAD modules, as shown on the opposite page.
PAD SERIES PLUG-IN MODULES (all have DIGITAL OUTPUTS)
Module
CHS
ADC
Sample
rate
ISOLATION
RANGES
Break-OUT BOX
ADD’L Features
ConnectoRS
8
24-bit
6 S/s/ch
350 V
±100 mV .. ±50V
PAD-CB8-BNC
PAD-CB8-B
20mA measurement with
external shunt resistor
DSUB25
PAD-CB8-J-P2
PAD-CB8-K-P2
PAD-CB8-K-M
PAD-CB8-T-P2
PAD-CB8-RTD
Automatic identification of
breakout box;
sensor lead wire break
detection
DSUB25
PAD-V8-P
V
PAD-TH8-P
V
PAD-AO1
8
24-bit
6 S/s/ch
350 V
According to the thermocouple
or RTD breakout box connected
1
16-bit
1 Hz
--
0 .. 10 V or
0 .. 20 mA (500 ohm load)
--
--
DSUB25
7
N/A
1 Hz
--
AC 120 V @ 0.5 A
DC 24 V @ 1 A
--
Drives up to 7 relays
DSUB25
OUT
PAD-DO7
RELAY
DSUB25 connector is on the front of the PAD module. Use either a mating connector or a breakout box to connect signals
BREAK-OUT BOXES for PAD-TH8-P, EPAD-TH8-P, CPAD-TH8-P only:
PAD Module Break-OUT BOXES
INPUT TYPE
Voltage
Thermocouples
RTD sensors
Model
Description
PAD-CB8-BNC
8 channel voltage break-out box, with BNC connectors
PAD-CB8-B
8 channel voltage break-out box, with BNC connectors
PAD-CB8-K-M
Mini thermocouple break-out, 8 chs, type K only
PAD-CB8-K-P2
Thermocouple break-out box, 8 type K inputs, type K
PAD-CB8-J-P2
Thermocouple break-out box, 8 type K inputs, type J
PAD-CB8-T-P2
Thermocouple break-out box, 8 type K inputs, type T
PAD-CB8-RTD
Pt100, Pt200, Pt500 (up to 250°C) and NI120 sensors
PAD-CB8-RTD-S3
Pt100, Pt200, Pt500, Pt1000 and Pt2000 sensors
PAD-CB8-K-M
66
Dewetron PRODUCT SELECTION GUIDE
PAD-CB8-BNC and -B
CABLE
Compatible with
2 meters (extensions
available)
PAD-V8-P
EPAD-V8-P
2 meters (extensions
available)
PAD-TH8-P
EPAD-TH8
2 meters (extensions
available)
PAD-TH8-P
EPAD-TH8
PAD-CB8-RTD
EPAD2 Series (RS485 interface)
EPAD SERIES external MODULES (all have DIGITAL OUTPUTS)
INPUT TYPE
CHS
ADC
Isolation /
Protection
S/R
RANGES
Break-OUT
BOX(es)
8
24-bit
ISO: 350 VDC
OV: 150 VDC
12 S/s/ch
±0.1, 0.15, 0.5, 1, 2.5, 5, 10, 50 V
N/A
8
24-bit
ISO: 350 VDC
12 S/s/ch
±30 mA
N/A
EPAD2-V8-LEMO
V
ADD’L Features
SIGNAL
ConnectoR(s)
LEMO EGG.1B.304
EPAD2-LA8-LEMO
DIN mounting option
EPAD2 boxes
connect together via
captive fasteners
Sensor disconnection or interruption
detection
-270°C to 1372°C
EPAD2-TH8-K, J, T
8
24-bit
12 S/s/ch
ISO: 350 VDC
-210°C to 1200°C
N/A
-270°C to 400°C
LEMO EGG.1B.304
Std mini T/C type,
color coded
EPAD2-RTD8-LEMO
8
24-bit
12 S/s/ch
ISO: 350 VDC
2- or 4-wire Pt100, Pt200, Pt500,
Pt1000 and NI120 sensors
N/A
LEMO EGG.1B.304
EPAD2-TH8-J/K/T modules have thermocouple connectors already and do not require a thermocouple break-out box
EPAD2-RTD8-LEMO (top) and EPAD2-TH8
(bottom)
DIN RAIL mount option
EPAD-BASE2 allows you to connect EPAD2
modules to any computer via USB or CAN BUS
EPAD2-TH8-K
... CPAD2 SERIES (CAN BUS interface)
CPAD2 SERIES external MODULES (all have DIGITAL CAN BUS OUTPUTS)
Module
CHS
ADC
ISOLATION
Sample Rate
CPAD2-TH8-K, J, T
V
RANGES
Break-OUT
BOX
ADD’L Features
SIGNAL
ConnectoR(s)
K: -270°C to 1372°C
8
24-bit
350 VDC
12 S/s/ch
J: -210°C to 1200°C
T: -270°C to 400°C
CPAD2-RTD8-LEMO
DIN mounting option
8
24-bit
350 VDC
12 S/s/ch
2- or 4-wire Pt100,
Pt200, Pt500, Pt1000
and NI120 sensors
(Not required)
8
24-bit
350 VDC
12 S/s/ch
4 to 20 mA current
sensors
(Not required)
CPAD2-LA8-LEMO
Std mini T/C type, color
coded
(Not required)
CPAD2 boxes connect together via captive fasteners
Sensor disconnection or
interruption detection
LEMO EGG.1B.304
RS-485 interface,
LEMO EGG.1B.304
RS-485 interface,
CPAD2-TH8-J/K/T modules have thermocouple connectors already and do not require a break-out box
Dewetron PRODUCT SELECTION GUIDE
67
ORION series A/D cards
ZT series SCOPE cards
SPECTRUM series TRANSIENT cards
Dewetron A/D cards
http://www.dewamerica.com/Products/ADcards/
OVERVIEW
All ORION series cards are SIMULTANEOUS SAMPLING - no
multiplexing! ORION Cards are available with 16, 22, and 24-bit
resolution.
The 22 and 24-bit cards have sigma-delta ADCs, which are ideal
for dynamic measurements such as noise and vibration, due to
their powerful anti-aliasing filters on board, dynamic range, and
tremendous vertical axis resolution.
Our 16-bit ORION cards employ successive approximation ADCs,
and are ideally suited for a wide range of applications in electrical
testing, power testing, and much more. All ORION cards feature at
least 2 synchronous counter/encoder inputs and 8 digital I/O lines,
and more are optionally available -- including higher voltage input
levels and programmable detection levels up to 40V.
In addition, two synchronous CAN BUS interfaces can be installed
on any ORION card.
Note: for our TRION modules, please see the DEWE2 section of
this catalog. These are plug-in modules that combine an ORION
card with top-quality signal conditioners.
68
Dewetron PRODUCT SELECTION GUIDE
◙◙
◙◙
◙◙
◙◙
◙◙
◙◙
◙◙
◙◙
◙◙
ORION CARDS:
Simultaneous sampling
Built-in counter/encoder inputs
Built-in digital I/O lines
Optional CAN BUS interfaces
Expandable and synchronizable
16, 22, and 24-bit
ISO9001, ISO14001
CE Mark
◙◙ OTHER AVAILABLE CARDS:
◙◙ SCOPE cards for PC-based
oscilloscope applications up to 4 GHz
◙◙ SPECTRUM series TRANSIENT
cards for 10-200 MHz performance
◙◙ DA series cards for analog outputs
ORION CARDS: 16-bit versions
ORION SERIES A/D cards with 16-bit resolution
Card
ORION-1616-100
CHS
ADC
Max sample
rate (B/W)
Input ranges
CNT/ENC
DI/O
16
16-bit
100 kS/s/ch
(B/W 50 kHz)
±1.25, ±2.5, ±5, ±10 V
2
16 (8/8)
Models and options
100
Standard version
101
Adds 2 CAN bus interface
102
+ 8 TTL DI lines with 25 VDC protection
+ 8 more TTL CNT/ENC or 32 TTL DI/O
103
Same as -102 plus 2 CAN bus interfaces
104
8 TTL DI lines 25 VDC protection
+ 8 adjustable CNT/ENC or +32 more TTL DIs (with
programmable threshold levels (0..40 V), input voltage range -35 to 60 V, AC/DC coupling)
105
Same as -104 plus 2 CAN bus interfaces
ORION-1616-500
16
16-bit
500 kS/s/ch
(B/W 250 kHz)
±1.25, ±2.5, ±5, ±10 V
2
16 (8/8)
Same options as ORION-1616-100 series
ORION-1616-1000
16
16-bit
1 MS/s/ch
(B/W 600 kHz)
±1.25, ±2.5, ±5, ±10 V
2
16 (8/8)
Same options as ORION-1616-100 series
ORION-3216-100
32
100 kS/s/ch
±1.25, ±2.5, ±5, ±10 V
2
16 (8/8)
100 = standard version, 101 adds 2 CAN bus interfaces
16-bit
ORION cards feature on-board RS485 for direct control of the Dewetron signal conditioning modules
A wide range of ORION cards are available,
from 100 kS to 1 MS/s/ch (simultaneous),
and with resolutions of 16, 22, and 24-bits.
Convenient break-out boxes are
available for many ORION cards
ORION CARDS: 24-bit versions
ORION SERIES A/D cards with 24-bit resolution
Card
ORION-1624-200
ORION-0824-200
ORION-0424-200
CHS
ADC
Max sample
rate (B/W)
Input ranges
CNT/ENC
DI/O
16
24-bit
204.8 kS/s/ch
(B/W 76 kHz)
±10 V
2
16 (8/8)
8
4
24-bit
24-bit
204.8 kS/s/ch
(B/W 76 kHz)
204.8 kS/s/ch
(B/W 76 kHz)
±0.1, ±0.5, ±2, ±10
V, voltage or IEPE
mode, TEDS support,
single-ended or differential
configuration, AC (0.15 or
3.4 Hz) or DC coupled
±0.1, ±0.5, ±2, ±10
V, voltage or IEPE
mode, TEDS support,
single-ended or differential
configuration, AC (0.15 or
3.4 Hz) or DC coupled
2
1
16 (8/8)
TRG input
only (no
DIO)
Models and options
200
Standard version
201
Adds 2 CAN bus interface
202
+ 8 more TTL DI lines 25 VDC protection
+ 8 more advanced TTL CNT/ENC or 32 TTL DI/O
203
Same as -102 plus 2 CAN bus interfaces
204
8 TTL DI lines 25 VDC protection
+ 8 adjustable CNT/ENC or +32 more TTL DIs (with
programmable threshold levels (0..40 V), input voltage range -35 to 60 V, AC/DC coupling)
205
Same as -104 plus 2 CAN bus interfaces
200
Standard version
201
(same as -201 above)
202
(same as -202 above)
203
(same as -203 above)
204
(same as -204 above)
205
(same as -205 above)
200
Standard version, 4 BNC connectors for analog
voltage or ICP (4 / 8 mA) inputs, TEDS support
SUB-D-9 connector with one advanced CTR/ENC
with programmable threshold levels (0..40 V), input
voltage range -35 to 60 V, AC/DC coupling, plus
one external trigger input
ORION cards feature on-board RS485 for direct control of the Dewetron signal conditioning modules
Dewetron PRODUCT SELECTION GUIDE
69
ORION CARDS: 22-bit versions
ORION SERIES A/D cards with 24-bit resolution
Card
ORION-1622-100
ORION-3222-100
CHS
ADC
Max sample
rate (B/W)
Input ranges
CNT/ENC
DI/O
16
22-bit
102.4 kS/s/ch
(50.1 kHz)
±10 V
2
16 (8/8)
32
22-bit
102.4 kS/s/ch
(50.1 kHz)
±10 V
2
16 (8/8)
Models and options
100
Standard version
101
Adds 2 CAN bus interface
102
+ 8 more TTL DI lines 25 VDC protection
+ 8 more advanced TTL CNT/ENC (or +32 more
TTL DI/Os)
103
Same as -102 plus 2 CAN bus interfaces
104
8 TTL DI lines 25 VDC protection
+ 8 adjustable CNT/ENC or +32 more TTL DIs (with
programmable threshold levels (0..40 V), input voltage range -35 to 60 V, AC/DC coupling)
105
Same as -104 plus 2 CAN bus interfaces
100 = standard version, 101 adds 2 CAN bus interfaces
ORION cards feature on-board RS485 for direct control of the Dewetron signal conditioning modules
Advanced Counter inputs
Dewetron ORION cards feature powerful counter inputs that
can handle a wide range of frequency inputs, from simple tach
outputs to full quadrature encoders with hundreds or even
thousands of steps per revolution. Our counters run at very high
speed in the background, regardless of the analog sample rate,
so you will get great performance all the time.
Advanced counter functions:
◙◙ Event Counting
DS-7 even features a counter/tach design screen so that you can
define and save your own counter/encoder “sensors,” and apply
them to any counter in any setup.
The -x04 and -x05 versions of ORION cards offer even wider
input ranges for your counter/tach signals, to handle more
demanding sensors.
DA series Cards for analog output
ANALOG OUTPUTS are sometimes needed in systems to
either replay data back out to another display or device in the
analog realm, or to generate one or more waveforms during
measurement, in order to drive a small shaker or to otherwise
create an excitation that the system will also record.
When you add any D/A option, you also need the software option
called DS-OPT-FG for 2 channel cards, or DS-OPT-FG-PROF for
cards with more than 2 channels. Up to 16 total DA channels are
supported. A connector PANEL or breakout box is also needed to
access the outputs.
DA-0216-750
16-channels, 16-bit, 750 kS/s/ch
DA4-1000-16
4-channels, 16-bit, 1000 kS/s/ch
DA8-1000-16
16-channels, 16-bit, 1000 kS/s/ch
DA8-CB-BNC
8 channel break-out box for DA4/8 cards above with BNC’s
70
Dewetron PRODUCT SELECTION GUIDE
◙◙
Gated Event Counting
◙◙
Up/Down Counter
◙◙
Frequency Measurement
◙◙
Period Time Measurement
◙◙
Pulse Width Measurement
◙◙
Two Pulse Edge Separation
◙◙
Quadrature Encoder (X1, X2, X4, A-Up/B-Down)
ZT cards for SCOPE SYSTEMS
ZT SERIES SCOPE A/D cards
Card
Chs
ZT4431
2
ZT4432
4
ZT4441
2
ZT4442
4
ZT4211
2
ZT4212
4
ZT4421
2
ZT4422
4
ZT4611
2
ZT4612
4
ARB waveform
generator
CHS
ZT5211
2
ZT5212
4
Max sample
rate
Bit
resolution
Bandwidth
500 MS/s/ch
13-bits
300 MHz
800 MS/s/ch
13-bits
300 MHz
Max. Input @ 50 Ω
Std
RAM
Trig
lines
INPUT Z
Coupling
Max input @ 1 MΩ
input Z
2
1 MΩ ||
12 pF or
50 Ω
AC or DC
±210 V [DC + peak
AC (<100 kHz)], CAT
I Peak AC, de-rated
20 dB/decade above
100 kHz
2
1 MΩ ||
12 pF or
50 Ω
AC or DC
2
1 MΩ ||
12 pF or
50 Ω
AC or DC
256 MS
512 MS
256 MS
512 MS
±5 V (DC + peak
AC), CAT II Input
load protection @
±6 VDC
256 MS
±300 V [DC + peak
AC (<100 kHz)], CAT
I Peak AC, de-rated
20 dB/decade above
100 kHz
1 GS/s/ch
8-bits
300 MHz
1 GS/s/ch
12-bits
300 MHz
4 GS/s/ch
8-bit
1 GHz
MAX Output
Rate
Bit Resolution
Bandwidth
(-3 dB)
Output Z
Ch/Ch
ISO.
Waveform Length
Output
Limit
Rise/Fall Time
(@ 50 Ω)
200 MS/s/ch
14-bits
50 MHz
50 Ω
≥60 dB
4 Samples to 32
MSamples/channel
≤ 7V into
50Ω
< 7 ns for 10V step
(50 MHz Filter)
512 MS
256 MS
512 MS
64 MS
2
128 MS
AC or DC
±210 V [DC + peak
AC (<100 kHz)], CAT
I Peak AC, de-rated
20 dB/decade above
100 kHz
Operation modes: Continuous, Burst, Binary modulation, Sweep. Trigger functions: External, internal, and software. Trigger modes: Edge & Pattern.
Spectrum cards for transient recorders
SPECTRUM SERIES TRANSIENT A/D cards
Card
CHS
Max sample
rate
M2i.4642
8
1 MS/s/ch
M2i.4651
4
3 MS/s/ch
M2i.4652
8
3 MS/s/ch
M2i.4022
4
20 MS/s/ch
M2i.4032
4
50 MS/s/ch
M2i.3121
4
10 MS/s/ch
M2i.3122
8
10 MS/s/ch
M2i.3131
4
25 MS/s/ch
M2i.3132
8
25 MS/s/ch
M2i.3024
2
100 MS/s/ch
M2i.3026
1
200 MS/s/ch
M2i.2031
2
200 MS/s/ch
Bit
resolution
Bandwidth
Input ranges
Std
RAM
Trig
lines
Options
16-bits
14-bits
±200 mV to 10 V
128
MS
12-bits
8-bits
±50 mV to ±10 V
256
MS
1
(Available for all of these cards)
M2I.XXXX-256MS 256 MSamples memory
M2I.XXXX-512MS 512 MSamples memory
M2I.XXXX-1GS 1 GSamples memory
M2I.XXXX-2GS 2 GSamples memory
M2I.XXXX-SH5 Synchronization of up to 5 cards
(M21-XXXX-256MS already included)
Multiple Spectrum cards in the same system requires the Sync option
Dewetron PRODUCT SELECTION GUIDE
71
Dewetron Interfaces
http://www.dewamerica.com/Products/Interfaces
TIME SYNC interfaces
Time sync interfaceS - INTERNAL & External
Model name
Inputs
outputs
IRIG A
IRIG B
Digital
clock to
A/D cards,
and data
via USB
2.0
Compatibility
INPUT Range
Form
factor
Rate(s)
IRIG-CLOCK-INT
Mounted inside Dewetron chassis, connects
internally via USB and clock lines to A/D card and
DEWE-CAM trigger input
DEWE-IRIG-CLOCK Card
Pin assignment
IRIG-CLOCK-EXT
Internal PCB
Modulated or
demodulated
signal types (auto
selection)
10 MHz
max.
0.5 Vp-p to 10 Vp-p
Aluminum
housing
External, high impact housing, connects to Dewetron systems via clock input connector(s)
Internal PCB
Mounted inside Dewetron chassis. Includes high
quality antenna and cable.
GPS-CLOCK-INT
DEWE-IRIG-CLOCK Card
Pin assignment
GPS-CLOCK-EXT
GPS
signals
Digital
clock to
A/D cards,
and data
via USB
2.0
NMEA standard or
differential signals
Requires line of sight
to GPS satellites
10 MHz
max.
Aluminum
housing
External, high impact housing, connects to Dewetron systems via clock input connector(s). Includes
high quality antenna and cable.
Internal PCB
Mounted inside Dewetron chassis. Includes high
quality antenna and cable, plus BNC IRIG input
DEWE-CLOCK-INT
DEWE-IRIG-CLOCK Card
Pin assignment
DEWE-CLOCK-EXT
IRIG and
GPS
Digital
clock to
A/D cards,
and data
via USB
2.0
Mod/Demod IRIG
(auto selection)
NMEA std or differential GPS
IRIG: 0.5 Vp-p to 10
Vp-p
GPS: requires line of
sight to GPS satellites
Comments, Features
10 MHz
max.
Aluminum
housing
External, high impact housing, connects to Dewetron systems via clock input connector(s). Includes
high quality antenna and cable.
VIDEO interfaceS
NTSC VIDEO INPUT interface
Model name
VIDEO-FG-4
Input
outputS
Streams
Storage type
Form
factor
Rate(s)
Comments, Features
4 x NTSC
video
DirectX into DS-7
Four independent color video
streams from
standard cameras
Direct to DS-7, video
streams are stored in
AVI or DVI format
PCI card,
half length
Std NTSC
30 fps DF
for each
input
Requires DS-7-PROF or higher
Requires Core2Duo processor or higher and
S-ATA hard disks and/or RAID system
Comments, Features
PCM interface
Bit sync / frame sync / decom interface
Model name
PCI-PCM-01
72
Input
outputs
Streams
Frame format Id
Form
factor
Rate(s)
PCM
Export PCM data to
Chapter 10 format
Async streams
supported
Supported
PCI card,
full length
Up to 33
Mbps
Dewetron PRODUCT SELECTION GUIDE
Requires DS-7-SE and OPT-PCM
(DS-7-PROF and IRIG-CLOCK-INT are required if analog data will also be acquired).
Requires Core2Duo or higher.
AVIONICS ARINC, MIL-STD-1553
BUS interfaceS - ARINC
PCI model
PCIe MODEL
Description (All include 3 ft mating cable. All require DS-7 and PLUGIN-ARINC/1553 software option)
PCI-A429-4-T
PCIE4L-A429-4-T
PCI Interface card with 4 Shared Tx/Rx Channels of ARINC-429 and 2 Rx/2 Tx ARINC-717 Selectable Channels
(Each 717 Rx/Tx Replaces Two 429 Channels).
PCI-A429-8-T
PCIE4L-A429-8-T
PCI Interface card with 4 Shared Tx/Rx Channels of ARINC-429 and 2 Rx/2 Tx ARINC-717 Selectable Channels
(Each 717 Rx/Tx Replaces Two 429 Channels).
PCI-A429-16-T
PCIE4L-A429-16-T
PCI Interface card with 8 Shared Tx/Rx Channels and 8 Rx Channels of ARINC-429 and 2 Rx/2 Tx ARINC-717 Selectable Channels
(Each 717 Rx/Tx Replaces Two 429 Channels).
PCI-A429-30-T
PCIE4L-A429-30-T
PCI Interface card with 16 Shared Tx/Rx Channels and 14 Rx Channels of ARINC-429 and 4 Rx/4 Tx ARINC-717 Selectable Channels
(Each 717 Rx/Tx Replaces Two 429 Channels).
BUS INTERFACES - MIL-STD-1553
PCI model
PCIe MODEL
Description (All include 3 ft mating cable. All require DS-7 and PLUGIN-ARINC/1553 software option)
PCI-1553-1D-T
PCIE4L-1553-1D-T
One Channel of Dual Redundant MIL-STD-1553 with Dual Function (BC/Mon or mRT/Mon) Capability
PCI-1553-2D-T
PCIE4L-1553-2D-T
Two Channels of Dual Redundant MIL-STD-1553 with Dual Function (BC/Mon or mRT/Mon) Capability
PCI-1553-3D-T
PCIE4L-1553-3D-T
Three Channels of Dual Redundant MIL-STD-1553 with Dual Function (BC/Mon or mRT/Mon) Capability
PCI-1553-4D-T
PCIE4L-1553-4D-T
Four Channels of Dual Redundant MIL-STD-1553 with Dual Function (BC/Mon or mRT/Mon) Capability
The standard cable included is 3 feet (~1 m) long. Longer cables optionally available.
BUS INTERFACES - ARINC & MIL-STD-1553 combo cards
PCI model
Description (Both require CBL-16036 cable, CBL-16037 cable, DS-7-PROF and option PLUGIN-ARINC/1553)
PCI-ARINC-16R/0T-1553-2
A429: 16R/0T 1553: 2 channels (redundant)
PCI-ARINC-8R/0T-1553-2
A429: 8R/0T 1553: 2 channels (redundant)
BUS INTERFACES - USB interfaces for ARINC 429, ARINC 708, and ARINC 717
USB 2.0 model
Description (Includes mating connector and USB cable (5 ft / 1.5 m), requires DS-7-PROF and option PLUGIN-ARINC/1553)
USB-ARINC-1410
ARINC 429 interface: 1R & 1T in a small USB module
USB-ARINC-1431
ARINC 429/717 interface: ARINC 429: 8R & 4T; ARINC 717: 2R & 2T in a small USB module
USB-ARINC-1440
ARINC 429 interface: 12R & 4T in a small USB module
USB-ARINC-1420
ARINC 429 interface: 4R & 2T in a small USB module
Note - there are additional models available for ARINC 708 and ARINC 717. Please ask your Dewetron rep.
BUS INTERFACES - USB interfaces for MIL-STD-1553
USB 2.0 model
Description (Includes mating connector and USB cable (5 ft / 1.5 m), requires DS-7-PROF and option PLUGIN-ARINC/1553)
USB-1553-1110
MIL-STD-1553 interface: 1 dual redundant monitor-only channel, in a small USB module
USB-1553-1111
MIL-STD-1553 interface: 2 dual redundant monitor-only channels, in a small USB module
USB-1553-1140
MIL-STD-1553 interface: 3 dual redundant monitor-only channels, in a small USB module
Note - there are additional models available for MIL-STD-1553. Please ask your Dewetron rep.
CAN BUS interfaceS
To add CAN BUS interfaces to your system, order the appropriate version of ORION card. ORION cards ending in odd numbers have
2 synchronous CAN BUS interfaces. No additional hardware needs to be installed! ORION CAN bus interfaces are therefore 100%
synchronous with the analog inputs.
FLEXRAY interface
Bit sync / frame sync / decom interface
Model Name
Description
PCI-FLEXRAY
PCI card with one FLEXRAY interface (Requires DS-7-PROF and PLUGIN-FLEXRAY). This interface is factory installed. A DSUB connector will be brought
out to one of the outside panels for easy connection of your Flexray signal.
Dewetron PRODUCT SELECTION GUIDE
73
Dewetron Sensors
http://www.dewamerica.com/Products/Sensors
OVERVIEW
◙◙ Tens of thousands of sensors are
compatible with every Dewetron
system, from thousands of
manufacturers
◙◙ Several key sensors are available
directly from Dewetron
Current sensors, from shunts to
◙
◙
There are some specialty sensors that we make ourselves, as
clamps and flexible coils
well as some standardized sensors like accelerometers and
Accelerometers, convenient IEPE
◙
◙
thermocouples, which we have chosen specificially to match our
(constant current) types, with and
signal conditioning.
without TEDS automatic sensor
identification
You can be confident that any sensor that you purchase from
Dewetron will be a perfect fit with your Dewetron system, according ◙◙ Thermocouples, in several standard
types and lengths
to the compatibility information here.
◙◙ Speed and distance sensors, GPS
Sensors are the first link the signal chain. Like every link, they are
based
vital to excellent data recordings. Every link in the chain is important, ◙◙ Inertial sensors, from entry level to
high-end
from the sensors to the signal conditioners, A/D converters, and the
◙◙ Video cameras, USB, firewire, and
software. A data acquisition system is only as strong as its weakest
ethernet
link.
There are literally tens of thousands of sensors which are
compatible with Dewetron’s world-class data acquisition systems.
We don’t sell all of them obviously, but there are a few key sensors
that we either manufacture ourselves, or offer here for your
convenience.
74
Dewetron PRODUCT SELECTION GUIDE
CURRENT SENSORS
Shunts
Model name
DAQ-SHUNT-1
DAQ-SHUNT-1-BNC
Form Factor
Input
OUTPUT
TYPE
Z
Acc.
Drift
Plugs directly into the banana jacks of
a DAQP-LV-B or similar module
Banana jacks
Banana plugs
AC/DC
0.1 Ω
0.1%
<±10ppm/K
Plugs directly into the 9-pin DSUB jack
of a DAQP-LV-D or similar module
BNC
9-pin DSUB
AC/DC
0.1 Ω
0.1%
<±10ppm/K
Small insulated box
30 cm cable and
banana plugs
30 cm cable and
banana plugs
AC/DC
0.1 Ω
0.1%
<±10ppm/K
Small insulated box
Banana jacks
30 cm cable and
banana plugs
AC/DC
0.1 Ω
0.1%
<±10ppm/K
Small insulated box
Banana jacks
Banana jacks
AC/DC
0.1 Ω
0.1%
<±10ppm/K
DAQ-SHUNT-3
DAQ-SHUNT-4
DAQ-SHUNT-5
AC/DC Clamps
Model name
DC Ranges
AC RANGES
OUTPUT
TYPE
Conn
PNA-CLAMP-150-DC
0.2 to 100 ADC and
0.5 to 1000A
0.4 to 150 AAC
0.5 to 1400 AAC
10 mV/A
1 mV/A
Ave or Peak value: 200.0
or 2000 A DC, (±1.3 % rdg.
±3 dgt.)
Ave or Peak value:
200.0 or 2000 A DC,
(±1.3 % rdg. ±3 dgt.)
Voltage: 1
V/f.s. or
Waveform
Accuracy/Comments
AC/DC
Banana
plugs
0.5 to 20A:1.5%
20 to 200A: 1.50%
100 to 800 A: 2.50%
800 to 1000 A: 4%
AC/DC
Banana
jacks &
cable
(dc or 45-65 Hz):
±1.3%rdg.±3dgt.
(10-45 & 65-1kHz):
±2.0%rdg.±7dgt
Built-in LCD meter
CLAMP-ACDC-2000
Power
9VDC battery
or external
power
9VDC battery
or external AC/
DC power
AC CLAMPS
Model name
AC RANGE(S)
Input
OUTPUT
TYPE
Z
Acc.
5A
Jaws
PNA connector,
voltage output
AC
<=1%
10 A
Jaws
PNA connector,
voltage output
AC
<=1%
20 / 200 A selectable
Jaws
PNA connector,
voltage output
AC
<=1%
20 / 200 A selectable
Jaws
Banana plugs and
cable, voltage
output
AC
<=1%
1000 A
Jaws
PNA connector,
current output
AC
<=1%
Drift
PNA-CLAMP-5
PNA-CLAMP-10
PNA-CLAMP-20
PNA-CLAMP-20-B
PNA-CLAMP-1000
Dewetron PRODUCT SELECTION GUIDE
75
CURRENT SENSORS
FLEXIBLE Current sensors
Model name
Input RANGES
COIL LENGTH
OUTPUT
TYPE
Z
Acc.
200 / 2000 A selectable
45 cm
Banana plugs and
box with 9VDC
battery
AC
<=1 %
200 / 2000 A selectable
80 cm
Banana plugs and
box with 9VDC
battery
AC
<=1 %
300 / 3000 A selectable
45 cm
Banana plugs and
box with 9VDC
battery or with
PNA connector
AC
<=1 %
300 / 3000 A selectable
80 cm
Banana plugs and
box with 9VDC
battery or with
PNA connector
AC
<=1 %
300 / 3000 A selectable
45 cm
PNA connector
AC
<=1 %
300 / 3000 A selectable
80 cm
PNA connector
AC
<=1 %
100 / 1000 A selectable
120 cm
Banana plugs and
box with 9VDC
battery or with
PNA connector
AC
<=1 %
Drift
PNA-A100-200-45
PNA-A100-200-80
PNA-A100-300-45
PNA-A100-300-80
PNA-FLEX-300-45
PNA-FLEX-300-80
PNA-A100-1000-120
Automotive Current Sensors (for DAQP-LV-BNC module)
Model name
image
SHUNT-MINI-1MR
SHUNT-MINI-500MR
SHUNT-ATO-1MR
SHUNT-ATO-500MR
SHUNT-MAXI-0.2MR
SHUNT-MAXI-500MR
SHUNT-STRIP-0.2MR
SHUNT-STRIP-500MR
76
Dewetron PRODUCT SELECTION GUIDE
VALUE
Fuse slot
1 mΩ shunt
MINI fuse
500 mΩ shunt
MINI fuse
1 mΩ shunt
ATO fuse
500 mΩ shunt
ATO fuse
0.2 mΩ shunt
MAXI fuse
500 mΩ shunt
MAXI fuse
100 / 100
STRIP fuse
500 mΩ shunt
STRIP fuse
OUTPUT
3 meter connection cable, BNC
Measuring range
Accelerometers
GENERAL PURPOSE, IEPE type (constant current)
Model name
SEN-ACC-3055B3T
SEN-ACC-3055B2T
SEN-ACC-3055B1T
SEN-ACC-3055B4
SEN-ACC-3056B3T
SEN-ACC-3056B2T
SEN-ACC-3056B1T
RANGE
OUTPUT
Connector
Mounting
TEDS
ISOLATED
WGT.
DIMS.
cable
±10 G
500 mV/g
10-32 side
connector
10-32 mounting
hole
Yes
Yes
8.6 g
0.50 x 0.62 in.
CBL-6011A10
±50 G
100 mV/g
10-32 side
connector
10-32 mounting
hole
Yes
Yes
8.6 g
0.50 x 0.62 in.
CBL-6011A10
±500 G
10 mV/g
10-32 side
connector
10-32 mounting
hole
Yes
Yes
8.6 g
0.50 x 0.62 in.
CBL-6011A10
±100 G
50 mV/g
10-32 side
connector
10-32 mounting
hole
No
No
10 g
0.50 x 0.62 in.
CBL-6011A10
±10 G
500 mV/g
10-32 top connector
10-32 mounting
hole
Yes
Yes
8.7 g
0.50 x 0.91 in.
CBL-6011A10
±50 G
100 mV/g
10-32 top connector
10-32 mounting
hole
Yes
Yes
8.7 g
0.50 x 0.91 in.
CBL-6011A10
±500 G
10 mV/g
10-32 top connector
10-32 mounting
hole
Yes
Yes
8.7 g
0.50 x 0.91 in.
CBL-6011A10
TRIAXIAL, IEPE type (constant current)
Model name
SEN-ACC-3023A
SEN-ACC-3023A3
SEN-ACC-3023A5
SEN-ACC-3023A1T
RANGE
OUTPUT
Connector
Mounting
TEDS
ISOLATED
WGT.
DIMS.
cable
±500 G
10 mV/g
1/4-28 4-pin
Adhesive
No
(Case)
3g
0.363 in.
CBL-6811xx
±1000 G
5 mV/g
1/4-28 4-pin
Adhesive
No
(Case)
3g
0.363 in.
CBL-6811xx
±5000 G
1 mV/g
1/4-28 4-pin
Adhesive
No
(Case)
3g
0.49 x 0.36 x
0.36 in.
CBL-6811xx
±500 G
10 mV/g
1/4-28 4-pin
5-40 mounting
hole
Yes
(Case)
6.2 g
0.45 x 0.45 x
0.48 in
CBL-6811xx
Many other accelerometers and types are available - please call with your requirements. The above are only the most common.
THERMOCOUPLES
Model name
THERMOCOUPLES
SEN-TH-K-1
Type K thermocouple with 1 meter long cable, mini TC, bare hot side ends. Also
available in longer lengths, and with probes on the hot side. Consult Dewetron.
SEN-TH-J-1
Type J thermocouple with 1 meter long cable, mini TC, bare hot side ends. Also
available in longer lengths, and with probes on the hot side. Consult Dewetron.
SEN-TH-T-1
Type T thermocouple with 1 meter long cable, mini TC, bare hot side ends. Also
available in longer lengths, and with probes on the hot side. Consult Dewetron.
Cable/Connector
Compatible module(s)
Standard mini T/C connector,
color coded
DAQP-MULTI
DAQP-THERM
DAQP-STG with MSI-BR-TH8J (or K or T)
EPAD2-TH8-J (or K or T)
DS-NET=TH8 ... and more!
Thermocouples area available in countless lengths and configurations - please call with your requirements.
Dewetron PRODUCT SELECTION GUIDE
77
DEWETRON SPECIALTY SENSORS
SPEED/DISTANCE GPS SENSORS
DEWE-VGPS-200C
The classic DEWE-VGPS-200C has a top notch 20 Hz GPS
inside, and 200 Hz derived speed and distance analog outputs
for fifth wheel applications in dynamic vehicle testing. In addition,
there are digital outputs for all signals, including speed, distance,
number of satellites, UTC time, latitude, longitude, acceleration,
and more. Connects to your DEWETRON system via RS232,
USB, or CAN BUS. The DEWE-VGPS-200C can also be used as
a timing/synchronization reference for Dewetron systems.
DS-7 compatible.
DEWE-VGPS-HS
Built purely for speed and no frills, the DEWE-VGPS-HS has
a powerful 100 Hz (non-interpolated) GPS inside. This is the
perfect replacement for fifth wheels in dynamic vehicle testing.
There are digital outputs for all signals: speed, distance, number
of satellites, UTC time, latitude, longitude, acceleration, and
more. Connects to your DEWETRON system via USB.
DS-7 compatible.
BOTH OF THE VGPS SENSORS ABOVE INCLUDE:
9-36 VDC input power, cigaratte lighter plug and 2m power cable,
magnetic antenna a 5 m cable, bright windshield display and 2 m
cable
GPS-USB-1
If you don’t need the update rate of the VGPS units above,
consider a simpler 1 Hz GPS sensor at a fraction of the cost.
Standard NMEA sensors with speed, latitude, longitude, and time
are available as USB outputs.
ENCODERS
We couldn’t find encoders that were reliable enough,
so we made our own:
CA-ENCODER-3600
Incremental hollow shaft encoder with fixturing and 10m cable,
3600 pulses per revolution = 0.1° resolution, max. 5000 rpm,
shaft Ø 12mm (end to end hollow shaft), IP65 protection
CA-ENCODER-900
Incremental hollow shaft encoder with fixturing and 10m cable,
900 pulses per revolution = 0.4° resolution, 0.1° resolution
in combination with DEWE-xxxx-CA2-PROF or DEWECRANKANGLE-CPU, max. 12000 rpm, shaft Ø 12mm (end to
end hollow shaft), IP65 protection
CA-RIE-360
Rugged Industrial encoder, 360 pulses per revolution plus one
zero-pulse, 0.1° resolution in combination with DEWE-xxxxCA2-PROF or DEWE-CRANKANGLE-CPU, max. 12.000 rpm,
standard disc with 40 mm hole for shaft-mounting (custom
versions available)
CA-RIE-720-SPEC
Rugged Industrial encoder, 720 pulses per revolution plus one
zero-pulse, 0.1° resolution in combination with DEWE-xxxx-CA2PROF or DEWE-CRANKANGLE-CPU, max. 6000 rpm, customer
defined shaft-mounting dimension for the disc
78
Dewetron PRODUCT SELECTION GUIDE
CA-RIE encoder by DEWETRON
CAMERA SENSORS
There are several cameras available for your Dewetron system,
starting with the tightly synchronized DEWE-CAM-01, which offers frame rates as high as 240 fps (depending on image size),
and connects via Firewire. If you need to record video far away,
use the DEWE-CAM-GIG-E-50, which connects to your Dewetron
system via low-cost ethernet cabling, 100 meters distant.
The least expensive type of camera is a DirectX webcam, available at any computer store and very inexpensive. These are ideal
for adding visual documentation to your tests at the lowest possible cost.
Analog NTSC and PAL cameras can be used easily by adding
the FG-VIDEO-4 PCI or PCIe card to your Dewetron system -please see the previous section for more info on that four channel
video interface card.
Infra-red cameras from FLIR can be interfaced with your Dewetron system very easily - see the next page for details.
Need to record HIGH SPEED video and then sync it to your Dewetron acquisition data? Our PHOTRON interface makes it easier
and more automated than ever! See info on the next pages.
DEWE-CAM-01
Our best continuous acquistition camera, connects via IEEE-488
to most Dewetron systems. Capable of high speed continuous
recording to disk in perfect sync with the data. Video adds a huge
amount of context to your recorded data, and is a hallmark of
Dewetron’s data acquisition systems. Imagine what synchronized
video could add to your important test data!
◙◙
VGA 640 x 480 progressive CCD
◙◙
Up to 70 fps @ full resolution
◙◙
High quality color correction algorithm
◙◙
Accepts C mount lenses
◙◙
Auto-exposure, and wide gain control
◙◙
Frames can be triggered from the Dewetron system, or free
running (best speed is achieved via triggered mode)
◙◙
Locking IEEE-488 (firewire) connector
◙◙
Standard camera mount tapped holes and movable plate
◙◙
Includes basic lens, cables, suction cup
◙◙
Requires DS-7-PROF software level
DEWE-CAM-GIG-E-50
Our latest continuous acquistition camera, connects via ethernet
(1 Gb) to most Dewetron systems. Capable of continuous
recording to disk in sync with the data. Key benefit: ethernet
cameras can be located far away from the acquisition system.
◙◙
Up to 55 fps at 780 x 580 px resolution
◙◙
Up to 175 fps at 640 x 120 px resolution
◙◙
Up to 100 m cable length (3 m standard)
◙◙
Mounting plate and suction cup
◙◙
6 mm lens included (accepts other lenses)
◙◙
Sony CCD sensor for outstanding image quality
◙◙
Requires DS-7-PROF software level
Dewetron PRODUCT SELECTION GUIDE
79
INFRA-RED CAMERAS
If you are using FLIR Thermovision cameras listed below, you
can connect them to your Dewetron system and record color or
grayscale IR data in sync with your data. The software option
called PLUGIN-FLIR adds support for data visualization, analysis
and storage with the cameras listed below.
◙◙
Supports FLIR models A300, A310, A315, A320, A325
◙◙
Supports FLIR model A615
◙◙
Supports FLIR models SC305, SC645, and SC655
◙◙
Requires DS-7-7-PROF or higher plus PLUGIN-FLIR
software option
Infra-red is a great way to see your data like never before. It is
ideal for machine health monitoring. You can see many electrical
problems from their heat signature long before they can be
measured any other way.
dynamically during braking tests, in a way that can never be
instrumented with wired sensors.
FLIR is the preeminent maker of infra-red cameras, which is
why we made this powerful software interface to some of their
most popular and useful cameras used within the test and
measurement realms.
In the automotive world, watch as brake pads heat up
A300
A310
A315
A615
320 x 240 pixel IR resolution
320 x 240 pixel IR resolution
320 x 240 pixel IR resolution
640 x 480 pixel IR resolution
MPEG-4 streamed video
Extensive analysis functions
16-bit image stream
16-bit image stream
C-VIDEO
Built-in alarm functions
GigE Vision™ standard compatibility
GigE Vision™ standard compatibility
Most affordable model
Ethernet/IP connectivity
GenICam™ protocol support
GenICam™ protocol support
Digital inputs/outputs
Digital inputs/outputs
Digital inputs/outputs
Windowing mode
SC305
SC325
SC645
SC655
320 x 240 pixel IR resolution
320 x 240 pixel IR resolution
640 x 480 pixel IR resolution
640 x 480 pixel IR resolution
9 Hz frame rate
60 Hz frame rate
25 Hz frame rate
up to 200 Hz frame rate
GigE Vision™ standard compatibility
GigE Vision™ standard compatibility
GigE Vision™ standard compatibility
GigE Vision™ standard compatibility
GenICam™ protocol support
GenICam™ protocol support
GenICam™ protocol support
GenICam™ protocol support
QuickPlot & ExaminIR software compatible
QuickPlot & ExaminIR software compatible
QuickPlot & ExaminIR software compatible
QuickPlot & ExaminIR software compatible
80
Dewetron PRODUCT SELECTION GUIDE
GigE and USB 2.0 HS
GigE and USB 2.0 HS
Compartment for optical filter
Compartment for optical filter
HIGH SPEED VIDEO CAMERAS
Photron high speed cameras listed below, Fastcam SA1 and
Fastcam 1024 PCI, allows video data acquisition of up to 100.000
fps, fully synchronized with analog data, triggering can be
software, at start of the measurement or external.
◙◙
Supports Photron Fastcam SA1 camera
◙◙
Supports Photron Fastcam 1024 PCI (card)
◙◙
Requires DS-7-7-PROF plus PLUGIN-PHOTRON-HS-CAM
software option
The FASTCAM SA1 improved provides blistering fast speed,
unmatched light sensitivity and true 12-bit performance. Capable
of over 5,000 full frames per second (fps) at mega pixel (1K x 1K)
resolution, the brand new CMOS sensor provides true twelve bit
pixel depth and is now capable of reduced resolution faster than
650,000 fps!.
The FASTCAM 1024 PCI is the world’s first PC based mega
pixel @ 1,000 fps camera is perfect for high speed PIV and DIC
applications. Utilizing the same super sensitive CMOS sensor
used in the Emmy award™ winning ultima APX and ultima APXRS cameras, the 1024 PCI offers true 10 bit images all the way
to a top speed in excess of 100,000 fps.
Building on the experience gained with the EMMY® award
winning ultima APX and ultima APX-RS cameras, the FASTCAM
SA1 is our most light sensitive camera yet, as well as providing
the greatest color fidelity of any high speed camera available,
thanks to true 12-bit performance. The FASTCAM SA1 provides
the perfect tool for those looking for mega pixel resolution at high
speeds, as well as those demanding sensitivity and performance
with an SDI digital output for TV/movie and commercial work.
The compact camera head is ideal for use in tricky to locate or
hazardous locations and is supplied with both C and F-mount
lens adapters. A single flexible cable sixteen feet (5 meters) long
connects the camera head to the PCI card which resides in either
a standard desktop PC or more portable PCI cradle connected to
a laptop.
Available with three memory options:
• Eight (8) Gigabytes for ~6 seconds record duration at full
resolution 1,000 fps
• Sixteen (16) Gigabytes for >12 seconds record duration at
full resolution @ 1,000 fps
• Thirty two (32) Gigabytes for >24 seconds record duration at
full resolution @ 1,000 fps
The FASTCAM SA1 is supplied with a RS422 LCD equipped
keypad, making computer-free setup and operation easier than
ever. Two rear panel BNC connectors provide users with both
composite video (NTSC or PAL) as well as SDI (720i) outputs.
Several different memory options are available; all fitting snugly
against the card to ensure never more than a single PCI slot is
required per camera system. Current options include:
• Standard 2 Gigabyte (GB) for 1.54 second record time at
1,000 fps
• Enhanced 6GB for 4.61 seconds at 1,000 fps
• Expanded 12GB for 9.22 seconds at 1,000 fps
• Maximum 24GB for 18.44 seconds at 1,000 fps
DIRECTX VIDEO CAMERAS
Just about DirectX camera, popularly known as “webcams,” can
be used with your Dewetron system. DS-7-SE supports ONE
camera, while DS-7-PROF supports multiple cameras.
◙◙
Low-speed (20 fps typical)
◙◙
Average latency can be offset in software
◙◙
Very inexpensive - and no software option required for one
camera support
Dewetron PRODUCT SELECTION GUIDE
81
ADMA SERIES GYRO / GPS sensors
The ADMA (Automotive Dynamic Motion Analyzer) gyro system
was developed especially for the dynamic testing of surface
vehicles. Using the ADMA, all dynamic movements of a vehicle
such as acceleration, speed, position, turning speed and angle
of the vehicle can be displayed and recorded right on your
DEWETRON system.
◙◙
Measurement of vehicle motion in three axes
◙◙
Dynamic attitude (pitch & roll) and heading determination
◙◙
Precise accel calculations via extended Kalman filter
◙◙
Highly accurate position data with GPS receiver
◙◙
Robust inertial strap-down system with no moving parts
◙◙
Directly interfaces with DEWETRON systems
A 32-bit processor unit continuously calculates the angular
orientation and position from internal sensor signals and external
information (e.g. GPS or velocity sensors).
The package is implemented in strap-down-technology without
moving parts and is therefore extremely robust and resistant to
shock and vibration.
The calculation algorithms are optimized for dynamic vehicle
tests such as slalom and circular movement. They take into
account the gravitational acceleration and rotation of the earth.
To improve the accuracy of positional data and heading angle
stability, an external speed signal (odometer or Correvit) or an
external GPS system can be connected. Alternatively, the ADMA
is also available with an internal GPS receiver (ADMA-G version).
The extended Kalman filter merges the internal with the external
sensor data to achieve high frequency output as well as amazing
accuracy. In this way, positional accuracy in the range of several
cm’s can be measured while the vehicle is in motion.
Data output is transmitted via a CAN bus which is connected
directly to your DEWETRON system, such as the DEWE-214,
DEWE-211, and DEWE-501. In addition to simple operation,
synchronization with other measuring signals is ensured.
With external GPS
Criteria
Accelerometers
Gyroscopes
GPS
Properties
Details
comment
Servo
1 mg accuracy
MEMS
5 mg accuracy
Closed loop FOG
0.1°/h in-run bias
open loop FOG
1°/h in-run bias
MEMS
5°/h in-run bias
ADMA-ECO+
ADMA-G
ADMA-G-ECO+
√
√
√
√
ADMA-G-ECO
ADMA-G-EL+
√
√
ADMA-G-EL
√
√
√
√
√
√
√
√
External
External
Yes
Yes
Yes
Yes
Yes
L1 TRK20
External
External
Yes
Yes
Yes
Yes
Yes
L!/L2 RTK2
External
External
Yes
Yes
Yes
Yes
Yes
GLONASS
External
External
Optional
Optional
Optional
Optional
Optional
omnistar
External
External
Optional
Optional
Optional
Optional
Optional
no
no
no
no
no
yes
yes
50 ~ 400
50 ~ 400
50 ~ 400
50 ~ 400
50 ~ 400
50 ~ 100
50 ~ 100
Vibration sensitivity
Data latency
82
ADMA
L1
Bandwidth
Accessories included
With INternal GPS
< 2 ms
< 2 ms
< 2 ms
< 2 ms
< 2 ms
< 2 ms
< 2 ms
Initialization time
< 2 min.
< 4 min.
< 2 min.
< 4 min.
< 4 min.
< 6 min.
< 6 min.
GPS sync
Available
Available
Available
Available
Available
Available
Available
Yes
For RTK2,
RTK20
For RTK2,
RTK20
ADMA-ATC Aluminum transport case
Yes
Yes
Yes
Yes
ADMA-PTC Plastic transport case
No
No
No
No
No
For L1
For L1
ADMA-CBL-CAN CAN cable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
ADMA-CBL-COM COM cable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
ADMA-CBL-POWER Power cable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
ADMA-CBL-PROG Programming cable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
For RTK2,
RTK20
ADMA-GPS-5
GPS antenna cable (5 m)
No
No
Yes
Yes
Yes
For RTK2,
RTK20
ADMA-GPS-ANT-L1L2-702-GG
GPS Antenna L1/L2 702-GG
No
No
Yes
Yes
Yes
For RTK2,
RTK20
For RTK2,
RTK20
ADMA-MAG-BASE
Magnetic base for GPS Antenna
No
No
Yes
Yes
Yes
For RTK2,
RTK20
For RTK2,
RTK20
ADMA-GPS-ANT-L1
GPS Antenna L1 AT575 with cable and
mag mount
No
No
No
No
No
For L1
For L1
Dewetron PRODUCT SELECTION GUIDE
ADMA / ADMA-G series applications
◙◙
Vehicle driving dynamics analysis
◙◙
Tire testing
◙◙
Adjustment of chassis systems
◙◙
Road surveys
◙◙
Road holding test
◙◙
Test track analysis
◙◙
Kinematic and elasto-kinematic analysis
◙◙
GIS data acquisition
◙◙
Verification of simulation models
◙◙
Verification of driver assistance systems
Deceleration/acceleration testing
◙◙
Steering robot navigation
◙◙
Increased
accuracy via BASE station
You can greatly enhance the accuracy of any GPS system
via the addition of a BASE station. ADMA series sensors are
compatible with the corrected / enhanced positional values
that these bases broadcast.
In addition, a BASE STATION is available from DEWETRON.
This outdoor base station is designed for the easy-to-use
generation of DGPS correction data for the mobile GPS
receiver in or connected to the ADMA inertial system. It was
developed especially for the dynamic testing of automobiles,
but it is also heavily used to test all kinds of surface vehicles,
including trucks, military tanks, and even trains.
The GPS outdoor base station is required to achieve highly
accurate RTK 2 position data in the range of 2 cm. This is
better than one inch accuracy.
MTI GYRO / GPS sensors
XSENS-MTI & MTI-G
The MTI series are lower cost inertial sensors for basic dynamic
applications. The MTI series are so small and lightweight that
they can even be worn. They are often used for human motion
capture and related applications, so you can believe their small
size and weight.
Both versions provide 3-D orientation, calibrated 3D acceleration,
the PLUGIN-XSENS for DS-7 software, and convenient USB 2.0
connection to your DEWETRON system.
XSENS-MTI-5
◙◙ Range ± 50 m/s2 ± 300 °/s
XSENS-MTI-5
◙◙ Adds GPS correction to the MTI-5
◙◙
Range ± 50 m/s2 ± 300 °/s
Dewetron PRODUCT SELECTION GUIDE
83
CC series shipping cases
MOB-DISP-17 mobile display
DPS-2410 AC/DC charger
Dewetron Accessories
http://www.dewamerica.com/Products/Accessories
OVERVIEW
We offer a variety of useful and important accessories specifically
for DEWETRON data acquisition systems. From mobile displays to
shipping cases, carrying bags, and more, we’ve got perfectly fitted
parts to help you get the most from your investment.
◙◙
MOBILE displays for field and vehicle testing applications
◙◙
BATTERY chargers and replacement batteries
◙◙
Isolated POWER supplies, AC/DC and DC/DC
◙◙
SHIPPING cases, rated for common carrier shipping
◙◙
CARRY BAGS for putting a system on your shoulder and moving it around
◙◙ VEHICLE testing specific items, like mounting poles
84
Dewetron PRODUCT SELECTION GUIDE
◙◙ Made specifically for and tested with
your DEWETRON system
◙◙ Guaranteed 100% compatibility
◙◙ Backed by the same full year
warranty of your data acquisition
system
◙◙ Top notch performance
Mobile displays
Model name
MOB-DISP-17
Description
Options
17” diagonal display - high resolution 1280x1024 px
CAPACITIVE USB touchscreen interface - supports multi-touch applications
Built-in USB 2.0 ports for easy connection of keyboards and USB sticks
Includes AC/DC adapter
Runs natively from DC power
Includes VGA, USB and power cables
Image
DISP-17-OPT (see next item)
DISP-17-OPT
Optional suction cups and 3 meter USB and VGA cable for automotive applications
Plus 1 m power cable with cigarette lighter plug on the input side
MOB-DISP-12A
12.1” diagonal display, 1024x768 resolution
Includes suction cups, AC/DC adapter
Runs natively from DC power
Includes VGA and power cables
Optional RESISTIVE touchscreen interface
DISP-15-TOUCH touchscreen interface
Batteries and chargers
Model name
BATT-95WH
Description
Options
Compatible with the DEWE-3200, DEWE-3210, DEWE-3050, DEWE-2600*,
DEWE-501, DEWE-571, DEWE-571-PNA, DEWE2-A4*, DEWE-5000*, DA-120,
DA-121, DA-124, DEWE-211*, DEWE-1201*
◙◙ Smart LITHIUM ION “Smart battery”
◙◙ Built-in LED display and push-button access to charge level
◙◙ Capable of hundreds of charge/discharge cycles - lasts for years
◙◙ 95WH, 14.4VDC 8A nominal output
Image
N/A
* battery power is optional in this model
Neutrino-4
RUGGEDIZED four battery charger, which can also be used as a VDC source:
◙◙ Charges up to four BATT-95WH smart batteries simultaneously
◙◙ Built-in LCD display of charge status
◙◙ Powered from 120/240 VAC
◙◙ Can also be used as a DC power SOURCE in certain DC powered or battery
powered DEWETRON systems
◙◙ Rugged MIL-STD-810 construction
◙◙ CE MARK, made in USA
BAT-CHARGER-1
Simple desktop charger for a single BATT-95WH
◙◙ Includes AC/DC adapter and power cord
◙◙ LEDs indicate charging status
◙◙ Plastic construction, suitable for office environment (not ruggedized)
BAT-BELTPACK
Canvas beltpack and one BATT-95WH, for mobile applications
◙◙ Includes coiled power cord with connector for various DEWE systems
(please specify which DEWE system you wish to power)
◙◙ Convenient belt-loops
◙◙ Makes the ideal portable power source (18-24VDC) for DEWE-CAMGIG-E-50 cameras, DEWE-43, and more.
DEWE-2600 with optional batteries
DEWE-3210 with standard batteries
N/A
DEWE-3050 with standard batteries
Dewetron PRODUCT SELECTION GUIDE
85
Power supplies
Description
Options
DPS-2410
Model name
Specifically made for the DEWE-3210 series, the DPS-2410 provides a powerful
24 VDC at up to 10 amps, continuous. This is designed to allow your DEWE-3210
to be charging the batteries AND running the system at the same time. Includes AC
power cable with standard US grounded instrument grade power cable (2m), and
DC-DC cable for connecting the DPS-2410 to the DEWE-3210 chassis, with keyed
LEMO connectors on each end.
If you have an older system
with round black power jack,
please request the proper
mating cable
DEWE-DCDC-24-300-ISO
Ideal for in-vehicle applications, solving two problems at once: if your DEWE
system does not have a wide enough DC power input range; and to ISOLATE the
power from the measuring instrument, to avoid ground loops and other measurement problems. The DEWE-DCDC-24-300-ISO is an external DC/DC converter
with high isolation, 9 ~ 36 VDC input range, LEMO EGJ.3B.302, includes. 2 m
cable to banana jacks, 24 VDC output, 300 W, LEMO EGG.2B.302 connector.
Image
N/A
Shipping cases
If you need to ship your DEWETRON system from point A to point B, you probably
want it to be working when it arrives. The rough handling and drops that happen
during common carrier shipment is well known, and no matter how rugged we try to
make our products, they cannot withstand an angry gorilla who wants to drop them
3 meters off a loading dock onto the cement. So protect your investment as best you
can with one of our CC series common carrier rated shipping cases.
Model name
CC-3210
CC-3040
CC-2600
CC-5000
Description
Compatible with the DEWE-3200, DEWE-3210, and older models DA-120, DA-121
◙◙ Common carrier rated shipping case
◙◙ Pull-out handle, and wheels
◙◙ Rated for international shipment
◙◙ Custom cut foam interior with holes made specifically for this model
Options
Image
N/A
Compatible with the DEWE-3050 and older DA-124 models
N/A
Compatible with the DEWE-2600
N/A
Compatible with the DEWE-2600
N/A
* Almost every Dewetron model has a CC series shipping case. Please ask your Dewetron sales representative for details.
CARRY BAGS
Most DEWETRON systems come with a carry bag. But after some years they
can get worn out, or lost. They are made so well, and with the features that our
customers like, that they get “repurposed” for other applications, and you need a
replacement. Here is one example - and there are many more available:
Model name
3200-BAG
Description
Options
Compatible with the DEWE-3200, DEWE-3210, and older models DA-120, DA-121
◙◙ Convenient shoulder bag for DEWE-3210/DA-120 series
◙◙ Carry straps and shoulder straps
◙◙ Heavy duty ballistic canvas construction
◙◙ Zippered end pouches for DPS-2410, cables, and accessories
N/A
Image
* Almost every Dewetron model has a carry bag available. Please ask your Dewetron sales representative for details.
86
Dewetron PRODUCT SELECTION GUIDE
Dewetron Calibration
http://www.dewamerica.com/Support
OVERVIEW
DEWETRON offers NIST traceable calibration of all our products,
right at our USA headquarters in Rhode Island. Our professional
CAL LAB is run by a seasoned professional with more than 10
years experience running major calibration services. We have
developed detailed calibration procedures under the Fluke MET/
CAL system, which also tracks every item that we calibrate in
a powerful database. The custom hardware and calibration
procedures that we use are also available for purchase by our
major customers who want to have the capability of performing
their own calibration. Our system consists of a Fluke 5500
calibrator and Agilent / HP 3458A multimeter, plus a Dewetron
CAL-RACK-16 base for calibrating plug-in modules (DAQ, PAD,
HSI). Then there are special connector fixtures for calibrating
MDAQ amplifiers and A/D cards, which are done in situ. The
whole thing is run under MET/CAL.
Please contact our support team today if you are interested in
having your Dewetron hardware calibrated, or if you would like a
quote on calibration equipment.
◙◙ NIST and Z540 traceable
CALIBRATION of your DEWETRON
systems
◙◙ Comprehensive AS-FOUND and/or
AS-LEFT Met/CAL calibration reports
always included
◙◙ Professional calibration service
◙◙ Capable of providing traceable
calibration of all Dewetron products
◙◙ Calibration equipment and MET/
cal procedures are available for
purchase, for those customers
who wish to perform automated
calibration themselves
◙◙ CAL-MANUAL also available for
customers to perform their own
manual calibration verification
Please call us today at: +1 401-284-3750 and ask for the CAL
LAB.
Dewetron PRODUCT SELECTION GUIDE
87
D900 FAST Datalogger
D900 Datalogger
http://www.dewamerica.com/Products/Dataloggers
OVERVIEW
If you close your eyes and think about a datalogger,
you probably see a cheap instrument that cannot
be calibrated, and which has a very low sample
rate. In other words, you think of bargain basement
data acquisition hardware with a lousy interface and
display, if any.
Well, open your eyes and take a look at the D900 data
logger. A remarkable NETWORKABLE instrument
with industry leading ISOLATED inputs and a human
interface no more complicated than your mobile
phone.
The D900 features 8 isolated input channels capable
of handling voltage, current and temperature. And
there are logic/pulse inputs and alarm outputs.
88
Dewetron PRODUCT SELECTION GUIDE
◙◙ High speed data logger with 8 channels
◙◙ 100 kS/s/ch sample rate when capturing to
internal RAM
◙◙ 1 kS/s/ch max sample rate when capturing
to USB stick
◙◙ Lowest sample rate: 1/minute
◙◙ Capture also to USB stick/flash media at
lower rates
◙◙ Includes PC software with remote control
capability
◙◙ PC software also allows conversion of data
files to Excel and text formats
◙◙ CE Mark, ISO9001
◙◙ Full year warranty
Multiple Input Types
VOLTAGE
TEMPERATURE
HUMIDITY
TRIGGER INPUT
COUNTING / RPM
LOGIC / PULSE
±20 mV to ±500V on BNC connectors
Thermocouples (J, K, T, E, R, S, B, N, W) (M3 screw terminal)
0 to 100% (requires optional B-530 sensor)
1 Trigger input
4 channels (counting, RPM, inst. mode)
4 channels of pulse or logic inputs (selectable as a bank)
8 fast input channels
The inputs are simultaneously sampled with 16-bit A/D converters. You
can set the sample rate anywhere from 1 S/minute/ch to 100 kS/s/ch
(10 µs interval) when capturing to the internal RAM. Or you can select
to capture to a USB stick that you plug in, at rates from 1 S/minute/ch
to 1 kS/s/ch (1 ms interval).
Most signals are input via the insulated BNC connectors, while the
thermocouples are connected via the M3 screw terminal connectors.
Thermocouple cables diameters up to 0.32 can be used.
great Gui / display
The D900 features a brilliant 5.7”
diagonal color display that serves
as the user interface. You can show
your data in these formats:
◙◙
Waveforms + digital values
◙◙
Enlarged waveforms
◙◙
Digital values + calculation results
◙◙
X-Y graph
Buttons to the right of the screen
complete the GUI, which is no more
complicated to operate than the
average mobile phone.
You can run the display at high
speeds if needed: up to 10 ms/
division. At the other extreme you
can run the display as slowly as 24
hours/division!
The free running display allows
you to monitor your data right
on the screen, even when you’re
not recording it. And because
waveforms are displayed on each
setup screen, you can even change
your settings while viewing the data.
D900 data logger
High voltage capabLE
The wide 500 V range allows 240 VAC power supply voltage waveform
measurements. Using voltage, current AND a logic input allows
simultaneous measurement of a test article’s power supply voltage,
current and sequential control of various points.
Dewetron PRODUCT SELECTION GUIDE
89
D900 specifications
Main system
Analog input channels
8
External I/O channels
Trigger input (1 channel),
Logic input (4 channels) or Pulse input (4 channels)
Alarm output (4 channels)
Sample rate (interval)
1 S/m to 100 kS/s (10 µs)
Time/division
10 ms/div to 24 hours/div
Timer functions
Date and time, daily cycle, hourly cycle
Withstand voltage:
Between
1 minute
Between
1 minute
input channel terminals and GND terminal:
at 1000 V peak-to-peak
input channel terminals:
at 1000 V peak-to-peak
Thermocouple accuracy* 8
Type:
R / S:
Meas range:
0°C ≤ TS ≤100°C
100°C < TS ≤300°C
R:300°C < TS ≤1600°C
S:300°C < TS ≤1760°C
Accuracy:
±7.0°C
±5.0°C
±(0.05% of rdg +3.0°C)
±(0.05% of rdg +3.0°C)
B:
400°C ≤ TS ≤600°C
600°C < TS ≤1820°C
±5.5°C
±(0.05% of rdg +3.0°C)
K:
-200°C ≤ TS ≤ -100°C
-100°C < TS ≤ 1370°C
±(0.05% of rdg +3.0°C)
±(0.05% of rdg +2.0°C)
E:
-200°C ≤ TS ≤ -100°C
-100°C < TS ≤ 800°C
±(0.05% of rdg +3.0°C)
±(0.05% of rdg +2.0°C)
T:
-200°C ≤ TS ≤-100°C
-100°C < TS ≤400°C
±(0.1% of rdg +2.5°C) ±(0.1%
of rdg +1.5°C)
J:
-200°C ≤ TS ≤-100°C
-100°C < TS ≤ 100°C
100°C < TS ≤ 1100°C
±3.7°C
±2.7°C
±(0.05% of rdg +2.0°C)
N:
0°C ≤ TS ≤ 1300°C
±(0.1% of rdg +2.0°C)
W:
0°C ≤ TS ≤ 2000°C
±(0.1% of rdg +2.5°C)
Trigger input
Trigger types
Start: Data capture starts on trigger
Stop: Data capture stops on trigger
External* 1
Trigger conditions
Start: Off, Input signal level (analog, logic/pulse),
Trigger combinations
Input signal level: Level OR, Level AND, Edge OR, Edge AND
Trigger modes
H (Rising), L (Falling), Window In* 2 , Window Out* 2
Alarm function
Alarm functions
Rising, Falling, Window In* 2 , Window Out* 2
Alarm output
Number of channels: 4, Open collector output (5V, 10 kΩ pull-up
resistance)
Pulse input
RPM mode
50 to 20 M RPM/F.S. (in steps of 1, 2, or 5)
Count mode
50 to 20 M C/F.S. (in steps of 1, 2, or 5)
Inst mode
50 to 20 M C/F.S. (in steps of 1, 2, or 5)
General
Accuracy conditions:
@ 23°C±5°C, after 30 minute warm-up time. Filter : Line
GND : connected
Calculation functions
Statistical calculations* 4 : Average, Peak, Maximum, Minimum, RMS
(2 calculations can be set simultaneously)
PC interface
Ethernet (10BASE-T/100BASE-TX), USB (High Speed supported)
provided as standard
Ethernet functions
Web server, FTP server, NTP client
OS compatibility
USB functions
USB drive mode (File transfer and deletion from internal RAM
memory)
Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions)
Software functions
D900 control, real-time data capture, data conversion to Excel & text
Internal memory
One million data points / Internal flash memory:Approx. 256 MB
Remote setup
Amplifier, data capture, trigger settings, alarm settings, and more
Display information
Analog waveforms, logic waveforms, pulse waveforms, digital values
Data capture
Real-time data:
Binary: Sampling speed: 10 μs to 60 s
CSV: Sampling speed: 10 ms to 60 s
Control software specifications
External memory
USB memory slot (High speed supported) USB memory slot (High
speed supported) USB memory slot (High speed supported)* 5
Display screens
Waveforms + digital values, enlarged waveforms, digital values +
calculation results, X-Y
Data conversion
Data between cursors, or all data
Display hardware
5.7” diagonal color LCD TFT display
2-screen mode
Simultaneous display of real-time data and recorded data (history)
Withstand voltage
Between each input channel and GND: 1000 V p-p for one minute,
between input terminals: 1000 Vp-p for one minute
Statistical display
Maximum, minimum, and average values
Options and accessories
Power supply
AC power input
100 to 240 VAC, 50 to 60 Hz, external AC/DC adapter is included
DC power input
8.5 to 24 VDC
Battery power
Two batteries can be installed (optional)
Power consumption
42 VA (when operating and charging batery with AC power)
Mechanical
Dimensions W x H x D
232 x 150 x 80 mm (approx)
Weight
1.1 kg (approx., excluding AC adapter and battery)
Operating environment
0 to 40°C, 5 to 85% R.H. (15 to 35°C when using batteries)
Vibration conditions
Equivalent to automobile parts Type 1 Category A classification
Input specifications
Input terminals
Voltage: insulated BNC (8)
Temperature: M3 screw terminals (8)
A/D subsystem
16-bit ADCs (14-bit effective)
Simultaneous sampling all analog channels
Isolation
500V
Input ranges, voltage
20, 50, 100, 200, 500 mV;
1, 2, 5, 10, 20, 50, 100, 200, 500 V F.S., 1-5 V F.S.
Thermocouple types
Thermocouples : K, J, E, T, R, S, B, N, W (WRe5-26)
Humdity input
0 to 100% (voltage 0 V to 1 V scaling conversion) with B-530 (option)
Input filter
Off, Line, 5 Hz, 50 Hz, 500 Hz (selectable on each channel)
Voltage accuracy* 8
±0.25% of F.S.
Maximum permissible
input voltage
Between input channel + and - terminals:
20 mV to 1 V: ±30 VDC; 2 V to 500 V : ±500 VDC
Between input channel terminals:
60 V peak-to-peak
Between input channel terminals and GND:
60 V peak-to-peak
90
Dewetron PRODUCT SELECTION GUIDE
Battery pack*6
B-517
Logic alarm cable
B-513, 2 meters
DC power input cable
B-514, 2 meters
Humidity sensor *9
B-530, 3 meters
Safety voltage probe
RIC-141, 1:1 input/output, 42 pF
BNC to BNC cable
RIC-112, 1.5 meters
BNC to banana plug cable
RIC-113, 1.5 meters
BNC - alligator clip cable
RIC-114, 1.5 meters
Rod-shaped K-type thermocouple
RIC-410, 1.1 meters
K-type thermocouple for
static surfaces
RIC-420, 1.1 meters
L-shaped K-type thermocouple for static surfaces
RIC-430, 1.1 meters
Notes:
*1 Logic alarm cable (B-513) is required.
*2 Cannot be set for logic input
*3 Maximum input frequency: 50 kHz, maximum number of counts: 15 M C
*4 In real time or when Between Cursors has been specified (during Replay)
*5 1 file = 2 Gbytes (depends on the USB memory stick used) *6 Please install two battery packs.
*7 Connections are made to both the BNC terminal and M3 screw terminal for the same channel.
*8 Thermocouple diameters T:0.32, others:0.65
*9 Operating temperature range: -25 to +80°C
Windows Software Included
Three measurement screens are provided for real
time data display, during acquisition:
• Y/T display • X-Y display • FFT display
Them after you’re done recording, the REPLAY
screen has a great ZOOM feature so you can
examine areas of interest in greater detail.
Easy setup
You can configure the most important parameters of
the D900 using the Windows software, too. Functions
like entering channels names are easier on the
computer, of course, where you have a full size
keyboard to work with.
More software functions
More analysis capabilities
Need even more analytical horsepower? Why not
use DS-7 software! If you buy an LT license, you
can import text format data files from the D900 and
perform a wide range of analytical functions:
◙◙
Formula math, including trigonometry, algebra, boolean, and
arithmetic
◙◙
Filtering - design your own IIR, FIR and FFT filters. Highpass, low-pass, band-pass, band-stop. Up to 10th order.
Bessell, Butterworth, Chebychev
◙◙
Integration, double integration, differentiation, double
integration, custom multi-sectional polynomials
◙◙
Array math processing and display in 2D and 3D modes
◙◙
Options available for power analysis, FRF, sine processing,
sound level metering, order tracking...
More FILE TRANSFER functions
The standard windows software provides these
additional capabilities:
The standard windows software provides these
additional capabilities:
◙◙
Direct to Excel - eliminates time-consuming file conversion
◙◙
◙◙
Search function - look for specific values within the data
◙◙
CSV batch file conversion - process multiple files at once
◙◙
Thumbnail display of captured files
Web server/FTP server - Waveform display and D900 setup
operations can be performed via a web browser. In addition,
data files captured to the D900’s internal memory or to a
USB memory stick can be transferred or deleted from PC.
◙◙
Ability to open text formatted data files in DS-7-LT or higher
software, for advanced analysis functions
◙◙
USB mode - When your D900 is connected to your PC
via the USB interface, you can perform fast and easy data
transfers from the internal memory to the PC.
◙◙
NTP client function - Connect the D900 to an NTP server via
an Ethernet connection to synchronize D900 time with NTP
server time at periodic intervals.
Dewetron PRODUCT SELECTION GUIDE
91
USA HEADQUARTERS
Dewetron, Inc.
10 High Street, Suite K
Wakefield, RI 02879
USA
Phone +1 401-284-3750
Fax: +1 401-284-3755
[email protected]
www.dewamerica.com
direct DEWE offices
NEW ENGLAND
Southern california
Detroit
SOUTHEAST USA
SALES PARTNERS
All over the USA
CANADA
MEXICO
COLOMBIA
BRAZIL
COSTA RICA
CHILE
DEWE-3050 with 17” REMOVABLE touchscreen, and up to 96 dynamic
channels with up to 1 MS/s/ch continuous acquisition to disk