Dewetron D300 -16, -8, D3PC-8, D3PC-4, DEWE-3050, DEWE-3210, DEWE-214, DEWE-3040-RM Data Acquisition System Product Selection Guide
Below you will find brief information for Data Acquisition System D300 D300-16, Data Acquisition System D300 D300-8, Data Acquisition System D300 D3PC-8, Data Acquisition System D300 D3PC-4, Data Acquisition System DEWE-3050, Data Acquisition System DEWE-3210, Data Acquisition System DEWE-214, Data Acquisition System DEWE-3040-RM. The D300 series is Dewetron's most affordable and flexible data acquisition platform. Each model in the D300 series comes standard with a computer, DS-7 software, wide-range DC power and a convenient AC/DC adapter. The D300 series accommodates a variety of signal conditioners and A/D cards allowing you to configure the system to meet your specific needs. The D3PC-8 and D3PC-4 models are small, 4-channel and 8-channel instruments that offer a high degree of flexibility for noise and vibration analysis, and are perfect for general purpose testing, modal analysis, and sound analysis. Other models such as DEWE-3050, DEWE-3210, DEWE-214 and DEWE-3040-RM offer additional capabilities and features.
Advertisement
Advertisement
Dewetron USA
Product Selection Guide
State of the Art Data Acquisition
Instruments for applications in: automotive - Aerospace - energy - industrial - process monitoring - R&D
w w w . d e w e t r o n . c o m
Dewetron worldwide HQ in Graz, Austria Dewetron American HQ in Wakefield, RI USA
Dewetron sales office in Laguna Hills, CA USA
DISCLAIMER
The information contained in this document is subject to change without notice. Accordingly, no guarantee is made as to the accuracy of any information contained herein.
NOTICES
This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All contents ©
1998-2012 Dewetron, Inc.
Dewetron is a trademark of Dewetron Ges.m.b.H.
SideHAND is a trademark of Dewetron, Inc.
All trademarks and registered trademarks are acknowledged to be the property of their owners.
Dewetron automotive center in Livonia, MI USA
ACCREDITATIONS
CAL LAB: NIST traceable, ANSI Z540 compliant
Details available at www.dewamerica.com/Support
DEWETRON products are tested to conform to:
MIL-STD-810F shock and vibration:
- Vibration: 514.5 procedure 1
- Shock: 514.5 procedure X
All portable products:
EN STANDARD shock and vibration:
- Vibration: EN 600068-2-6
- Vibration, random: EN60721-3-2 Class 2M2
- Shock: EN 60068-2-27
CERTIfICATIONS
ISO-9001 Dewetron Ges.m.b.H.
ISO-14001 Dewetron Ges.m.b.H.
CE Mark
10 9 8 7 6 5 4 3 2 1
Version 4.0.0
June 2012
Printed in USA
2
Dewetron ProDUCt SeLeCtIon GUIDe
Product Selection Guide
OVERVIEW D300 / D3PC
DEWE-3210
DEWE-3050
WhAt MAkEs A DEWEtrON...?
SySTEM ARCHITECTURE
DS-7 SOFTWARE
4
ECONOMICAL INstruMENt...
CHOICE OF SIGNAL CONDITIONERS
WIDE RANGE DC POWER
MADE IN USA
12
POrtAbLE INstruMENt...
CHOICE OF SIGNAL CONDITIONERS
BATTERy POWERED
MADE IN USA
bENChtOP INstruMENt...
MORE CHANNELS THAN ANy OTHER
ALL-IN-ONE
BATTERy/AC POWERED
MADE IN USA
22 30
DEWE-214 COnDITIOnERS A/D CARDS
DEWE-3040-RM
rACk-MOuNtING WIth DIsPLAy...
19” RACk COMPATIBLE
HUGE 19” WIDE SCREEN
MADE IN USA
40
uLtIMAtE POrtAbLE...
DC POWERED, FLEXIBLE
TOP NOTCH CONDITIONERS
BATTERy OPTION
50
IDEAL frONt-END...
ISOLATED / DIFFERENTIAL
CONDITIONERS
EVERy SENSOR, SIGNAL
56
tOP A/D tEChNOLOGy
16, 22, AND 24-BIT
SIMULTANOUS SAMPLING
DIGITAL INPUTS
COUNTERS
66
DATALOGGERS
InTERfACES
SEnSORS ACCESSORIES
INtErfACEs...
IRIG / GPS TIME CODE
CAN, FLEXRAy, XCP, OBDII
ARINC, 1553, PCM
NTSC/PAL VIDEO
PrOvEN sENsOrs
CURRENT SENSORS
ACCELEROMETERS
SPEED SENSORS
THERMOCOUPLES
CAMERAS
70 72
GrEAt ADD-ONs...
MOBILE DISPLAyS
SHIPPING CASES
CHARGERS AND BATTERIES
CARRyING BAGS
sMALL LOGGEr...
VOLTAGE AND TEMPERATURE
INPUTS
LOW AND HIGH SAMPLE RATES
82 86
3
Dewetron ProDUCt SeLeCtIon GUIDe
What Makes a Dewetron...
. . . a D e w e t r o n ?
there are several things, but far and away the most important thing is the ability of our data acquisition systems to display, acquire, and replay
AsyNChrONOus MuLtI-DOMAIN DAtA.
that’s a mouthful - but what does it really mean?
MuLTI-DOMAIN MEASuREMENTS...
Consider testing a car or truck. you will want to hook up some sensors of your own, such as accelerometers, thermocouples,
RPM, etc. In addition, it is very handy to be able to tap into the vehicle CAN BUS and grab one or a hundred parameters, like wheel speeds, steering wheel position, pedal positions, coolant temperature, etc.
So immediately we have ANALOG sensor data + CAN BUS digital data + GPS serial data + VIDEO frames... all of these data types exist in different domains, and they come into our system at their own rates, i.e., asynchronously. Dewetron systems can easily handle asynchronous multi-domain data input from these sources
AND MORE!
In the aerospace world there are additional interfaces, such as
ARINC 429, 1553, and PCM data, as well as GPS and IRIG time code. We offer all of these interfaces, and more, for most of our systems. More interfaces are being added all the time.
P u t i t a l l t o g e t h e r , a n d y o u h a v e a D e w e t r o n d a t a a c q u i s i t i o n s y s t e m
– a v a i l a b l e f r o m j u s t a h a n d f u l o f c h a n n e l s , t o d o z e n s , h u n d r e d s , o r e v e n t h o u s a n d s .
D e w e t r o n : m u l t i - d o m a i n , t o u g h , s c a l a b l e , y e t e a s y t o u s e !
RuggED, fIELD-wORThy DESIgN
Another important Dewetron distinction is our MIL-STD and EN
STD MECHANICAL DESIGNS , which provide excellent shock and vibration specifications. Rugged designs allow your Dewetron system to go just about anywhere, and get the job done. We offer solid state hard drives for our systems, which provide enhanced reliability in harsh shock and vibration environments.
SCALABLE..
A third Dewetron hallmark is SCALABILITy - the ability to scale up from a few channels to many, and to distribute these channels in several locations. This is critical in both portable and fixed installation applications alike.Consider a large scale testing facility, instrumenting a large aircraft with hundreds of dynamic sensors (such as accelerometers) and perhaps thousands of static measurements.
POwERfuL SOfTwARE...
Award-winning DS-7 data acquisition SOFTWARE provides the interface to all your Dewetron hardware, the interfaces, signal conditioners, A/D cards ... and allows you an unprecedented level of control over how the screens are set up, and how they look.
EASy TO uSE...
Engineers and technicians appreciate the ease of use and short learning curve that DS-7 provides, and have come to rely on it for demanding data acquisition applications, all over the world.
4
Dewetron ProDUCt SeLeCtIon GUIDe
O n l y f r o m D e w e t r o n . . .
◙
◙
◙
◙
Record every kind of analog sensor that is in use today: strain, pressure, vibration, temperature, force, voltages, currents, displacement, distances, and more
Also record GPS parameters such as latitude, longitude, speed, distance, etc in mobile applications
Sync your measurements to absolute time via IRIG or GPS
Add more interfaces to your Dewetron system, such as VIDEO, PCM data from spacecraft and missiles, MIL-STD-1553 and ARINC 429 from aircraft, CAN BUS from vehicles and engines, and many more
DEWEtrON Applications:
Aerospace
Automotive
Transportation
Manufacturing
Research & Development
Energy & Power
Anywhere that data acquisition is found!
In this product selection guide you will find nice overview of our most important products, starting with portable systems.
Dewetron portable instruments are available in several popular models, all battery powered and fully capable despite their small size.
Next come our benchtop instruments, which are typically larger than the portable models, and yet more expandable as a result.
Then we present our front-end instruments, which do not have a computer or display of their own - you connect them to your own computer using USB or ethernet, depending on the model.
Then come rack-mounting instruments: we offer 19” rack compatible instruments both with and without a built-in display.
This leads us to our large-scale instruments - which are meant to start small but scale “up” into the hundreds or even thousands of dynamic and static channels.
Then we present our
application specific instruments. These
are Dewetron “all in one” instruments which have been geared to address specific applications, such as ENERGY TEST. Several more models apply Dewetron technology and innovation to other applications, such as the classic SCOPE, and more.
Next come signal conditioners, a complete range of single and multi-channel signal conditioning modules for both fast and slow signals.
Our top-notch A/D cards follow. These are mission critical!
Then our interfaces, such as ARINC, IRIG, GPS, 1553, PCM...
Then sensors, including our own video cameras, and more.
Finally we present our accessories, such as MOBILE displays, and accessories related to the power system of your Dewetron system, especially battery-powered models, which require batteries and related accessories.
Battery power provides unprecedented flexibility in terms of how and where you can work!
Dewetron ProDUCt SeLeCtIon GUIDe
5
Software Ties it All Together...
Within every Dewetron system is our award-winning data acquisition software package, DS-7 Steadily improved since
2000, DS-7 provides complete control over all of the hardware interfaces within
the system.
Fast Channel Setup & Scaling
Fast, easy and accurate configuration is the goal, so we’ve included advanced features like an XML sensor database that you can populate with all your sensors
– then just pick them from the list on a given channel’s setup screen. Also COPy and PASTE channel configurations, and grouping for functions such as
ZERO and high/low calibration. Even auto-ranging and display scaling are built-in.
Below, the setup dialog from one of our DAQP-STG signal conditioners. Starting from the top-right, you set the actual hardware settings of the module, including measurement mode (bridge, voltage, resistance, etc.), sensitivity, filtering, bridge completion, excitation, etc.
◙
◙
◙
◙
◙
Ds-7 key features:
◙
◙
Software basis of every DEWETRON system
Records analog + digital + VIDEO + CAN + ARINC + 1553 +
PCM...and other kinds of data
SyNCHRONOUS MULTI-DOMAIN measurements!
No license required to review/replay/export data - install on any PC
Easy setup and configuration - save unlimited numbers of setups
“Open” data format (version 7.0 and higher)
Extensible via COM/DCOM software plugins - write your own, or hire Dewetron to create what you need
Then moving to the left, you can enter in the channel name, description, and engineering units. In this section you may also set a sample rate divider for this channel, so that although it is sampled at the selected dynamic rate, it does not have to be written at that rate.
In the bottom left section you can perform linear scaling in one of several convenient ways. you can even perform end-to-end scaling incorporating the output of your sensor. That’s what the “from average” and “from RMS’ buttons are for: DS-7 will calculate the slope based on the actual output of your static or dynamic sensors.
The bottom-right section is a handy reference, a bar graph scaled on the left side with the actual voltage coming in, and on the right side, with the scaled value.
The buttons for Average, AC RMS, and Min/Max control which calculated values of the channel are displayed in the bar graph.
Main setup screens
In the picture above, you can see the main analog setup screen, where you can turn on/off channels, select any particular channel for setup as shown in the previous section, copy and paste channel settings, and more.
Just press the Used/Unused buttons on the left side to turn on/off channels, in whatever combination you like. The top of the column has a button for turn ing all channels on/off at once.
Notice the other buttons, which reveal setup screens for other input types and functions:
Standard input types include analog, digital, counter, video, GPS, and Math.
But you can add other input types, such as CAN BUS, PCM, ARINC 429,
1553, PCM data, and many more. All channels are recorded synchronously, time stamped against the high resolution clock within the ORION A/D card
(which can be synched to IRIG or GPS absolute time if required).
6
Dewetron ProDUCt SeLeCtIon GUIDe
Virtual channels - before and/or after recording
Create whatever channels you need from the real channels, using algebra, trig, math, logic, and programmable filtering (IIR, FIR,
FFT), integration (INT), DINT, DER, DDER, and much more. Starting with v7.0 you can add virtual channels AFTER recording as well.
Nothing can touch the flexibility and sheer power – while still being easy to learn – of DS-7.
There are built-in MATH functions such as BASIC STATISTICS which calculate popular functions automatically, such as RMS, average,
MIN, MAX, STD DEC, and many more. Just checkmark the channels you want to process, and which outputs you would like from each channel. you can also set the rate at which these statistics are calculated and stored.
Above: main MAtH channel screen right: BASIC StAtS setup dialog
Digital Filtering
You can create one or many filters, and process channels through any or all of them. There are FIR, IIR, and FFT type filters. The IIR setup also includes programmable integration, double integration, derivation, double derivation, and polynomic processing with multi-sectional coefficients.
The FIR filter type has the advantage of NO PHASE SHIFT! This is possible only in the digital domain, of course, because every real analog filter imposes a delay, or phase shift.
The FFT filter math function provides the power of our spectral analyzer, and a great selection of windowing types, like
Hamming, Hanning, Blackman, and more.
And as mentioned, if what you want to do is too intensive for the CPU in real time, you can set up and execute all of these functions AFTER recording, where the CPU can handle anything that you can dream up for it to do.
IIr FILter setup dialog
Advanced options
The DSA version of DS-7 includes advanced features for dynamic signal analysis, including order tracking, rotational and torsional vibration, SRS, Sine Processing, Frequency Response
Function, Human Vibration Analysis, and more. It also adds some additional display outputs, such as Orbit, Waterfall, and 1/3rd
Octave Analysis.
you can also order these options individually, if you just need something like Blade Balancing, or Order Tracking with waterfall displays, for example.
Dewetron ProDUCt SeLeCtIon GUIDe
7
Flexible and Easy Display Setup
Not just easy, but amazingly powerful and flexible. Put any graphical display object - strip charts, scopes, meters, 3D graphs, tabular lists, alarm lights, FFT’s and Xy plots - anywhere on the screen, and assign any channel(s) into them.
Then save everything to a convenient setup file which contains both the channel setup/scaling
AND the displays.
Already recorded your data? No problem; you can change the display design of any existing data file, and then save it into the data file.
Or apply a common screen design layout to a large number of files all at once!
Screen Name Setup Mode
Click the SCREEN NAME icon and you can rename, reorder, add or delete screens and their icons as they are shown across the main toolbar!
Screen name setup
Property setup mode
Hide/show this panel
DeSIGn MoDe
Show channel from selected widget
Show channels as a list
Show channels in groups
Hide/show panel
Screen Design Mode
Click the DESIGN button and you are immediately shown a strip of icons which contain the display “widgets” that you can put onto any screen:
Design the screens of your dreams, simply by dragging the widgets around, sizing them, and assigning any active channels into them
The screen design of DS-7 has won awards all around the world due to its brilliance. Once you try it, you will never want to work any other way. Just click any widget and its properties will be shown on the left design panel. Click and change whatever you want. you can drag channels right off the channel list on the right side of the display, or click a widget first and then click one or more channels from the list to assign them into it.
8
Dewetron ProDUCt SeLeCtIon GUIDe
Choice of Recording modes
The default mode is ALWAyS FAST, meaning that you simply press STORE and the system records your data at the selected sample rate.
Or select FAST ON TRIGGER mode, and then set up one or more trigger conditions, with pre and post-trigger time. DS-7 offers a wide range of trigger logic selections, including triggering from the actual signal, the RMS or AVE value of the signal... triggering from a live FFT of the signal, from absolute or relative time, and more.
REDUCED storage still samples at the selected dynamic rate, but writes to disk at a lower rate that you can control. So you still get the amplitude resolution without the big file.
But perhaps the most interesting is a combined mode called
FAST ON TRIGGER, SLOW OTHERWISE, where data
BETWEEN the triggers is stored at the reduced rate! This is a kind of “dual speed mode” that provides you full speed data when you want it, and reduced data when you don’t.
Annotating Recordings
During acquisition you can press the space bar and add simple events to the datafile. Or press the N key and type a message.
A third way is to connect a simple PC microphone and record a voice annotation. All events are time-stamped and added to the datafile.
All of these markers are shown during replay, and you can search for them by double-clicking them inside the log. It couldn’t be easier. you can even add more markers after recording, to further annotate the data file.
You can also define a DATA HEADER screen that will pop up when you record data, where your operators can enter some whatever information you want them to.
All of data header responses are captured into the data file, and can br printed and displayed after recording, so you can create a perfect record which is highly self-documented.
Click and Zoom
In the replay mode, you can click and drag the cursors into position around an area of interest, then simply click between them to zoom the area of interest to the width of the graph. It is really that simple.
If your system has a touchscreen you zoom in with one finger!
To zoom back out, just right-click on the graph... or use the blue [-] button at the bottom right corner of the graph.
Below, when you open a file, the whole thing is showed. with one finger (or the mouse), drag the cursors across the area of interest, as shown here:
Above: now just touch (or click) once between the cursors, and that area will be zoomed to the entire width of the recorder window! right: notice how the selected area is shown at the top in the reference bar. this small highlighted window can also be dragged with your finger or mouse.
Dewetron ProDUCt SeLeCtIon GUIDe
9
Easy EXPORT to a wide range of formats
Once you get your data into DS-7, you need to get it out, and we’ve provided numerous standard export formats that you can translate your data to. you can even have DS-7 automatically convert data files as soon as you press STOP if you like.
Print-outs on multiple pages
Make the screen look just the way you want, and then press the PRINT button. Choose from portrait or landscape modes, and type some additional text into the title bar if you like. Link your company logo and it will appear on the print-outs automatically.
Want to emulate those obsolete paper recorders without the expensive thermal paper?
Click the box called MULTIPLE PAGE printout and then choose how much time you want to print on each page. Uses any WIndows printer, even in full color.
Above: get your data to look the way that you like it (including zooming, adding meters, scopes, etc - and then click the PrInt screen...
Above: You get a print preview. From here you can turn on or off a header with your logo and other info to print, additional comments, or select the MULtI-PAGe option.
Math analysis after recording
As mentioned, with DS-7 comes the ability to run all of the math functions during or after recording, so you can create filters and dozens of other advanced functions and cross-channel calculations after recording and DS-7 will calculate and generate them upon demand.
The original “raw” channels are never affected in any way - new virtual channels are simply created.
In addition to a powerful FORMULA editor, where you can create just about any function, there are dedicated MATH function groups for FILTERING, SPECTRAL ANALySIS, REFERENCE
COMPARISONS, ARRAy PROCESSING, STATISTICS, and more.
In DS-7 you can also re-scale data after recording, in case an error was made during set-up. Great data in; great data out. Easy seup. Incredible recordings.That’s the power of DS-7.
10
Dewetron ProDUCt SeLeCtIon GUIDe
System Architecture Overview
At the center of most Dewetron systems is one of our A/D cards. Not only does this card provide high resolution digitizing of the analog signals, but it serves the vital role of providing a high speed master CLOCK for synchronizing the incoming data from PCM, ARINC, 1553, video cameras, CAN bus data, and more. So whether you are testing cars, airplanes, factory machines, spacecraft, trains, all of the data are recorded synchronously all the time, every time.
Databus interfaces
PCM, ARINC 429, 1553
All analog sensors:
STRAIN GAGES
ACCELEROMETERS
MICROPHONES
VOLTAGE
CURRENT
RTDs and T/C’s
LOAD CELLS and more
Various sensors connected via ETHERNET inteface(s)
EPAD modules - connected via SERIAL inteface(s)
VIDEO input
NTSC or camera
DEWE-A/D
Digital input
Digital output
DEWE Modules
Signal conditioning
Sensor supply
Analog input
CAN BUS interfaces
Counter input
Tach pulse
[
SYNC from another
Dewetron system
]
GPS UTC time/speed Source or IRIG time code interface upper: DEWE-IRIG-CLOCK lower: DEWE-GPS-CLOCK
Note - either can be installed inside the
Dewetron chassis, or remain external boxes as shown here ext. clock int. clock
Rugged PC
PC
DS-7
OPTIONS
OPT-PCM, etc.
Dewetron ProDUCt SeLeCtIon GUIDe
11
D300-16 with MDAQ conditioners
D300 series
www.dewamerica.com/Products/D300
OVERVIEw
The D300 is our most affordable and flexible data acquisition and computing platform. It can be configured in several basic ways:
◙
◙
◙
◙
◙
◙
As an 8-channel noise and vibration analyzer
(ORION-0824-200 A/D card inside): D3PC-8
As a 4-channel noise and vibration analyzer
(ORION-0424-200 inside): D3PC-4
With up to 16 ISOLATED SC4 series basic signal conditioners, in blocks of four channels (any four can be installed), and any
A/D card inside
With up to 16 MDAQ DIFFERENTIAL signal conditioning channels, any two MDAQ-SUB blocks of 8 channels, and any
A/D card inside
With any ZTEC series SCOPE card, as 2-channel PC-based scope
With any ARINC or 1553 interface card, as a highly portable aircraft BUS recorder/analyzer
There are many additional instruments that can be built on the D300 platform - it’s just that flexible. And we have done everything to make it as affordable as possible without sacrificing quality or reliability.
12
Dewetron ProDUCt SeLeCtIon GUIDe
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
Highly configurable and economical system
Choose from direct inputs, SC4 isolated conditioners, or any two MDAQ-SUB series signal conditioners
Full power DEWE computer inside
One half-length PCI slot inside
Compatible with ORION and AD series A/D cards
500 GB removable HDD keyboard and mouse are included
VGA output connector (supports XGA resolution displays)
Wide range DC power input, plus a convenient AC/DC adapter is included
Metal door protects the computer interfaces
(ethernet, USB, VGA, A/V, etc.)
Ruggedized construction, MIL-STD, CE
MARk, and more
Small footprint D3PC available also as a pure computer or PCI bridge host platform
Made in USA
Full year warranty
mDaQ Differential ConDitioners
The D300 model is compatible with our MDAQ differential conditioners. You may choose any two of the MDAQ-SUB 8-channel conditioners to be installed on the front panel, with BNC or DSUB connectors.
The most popular MDAQ-SUB is the STG-D, which is a strain/bridge universal type signal conditioner, because in addition to handling any kind of strain gage and low voltage by itself, it also accepts our MSI multiple sensor adapters, which convert each input to something different, such as IEPE accelerometers, charge accelerometers, ±200V signals, RTDs, and even high bandwidth thermocouples.
But there are other MDAQ-SUBs, including 8 channel
IEPE accelerometers, 8 channels of voltage from ±125 mV to ±200V, and more.
sC4 isolateD signal ConDitioners
When configured for SC4 conditioners, you can pick any four of our ISOLATED 4-channel conditioners, for a total of 16 inputs.
There are SC4 conditioners for different voltage levels, different strain gage conditioners in full or half bridge, with various thermocouples, and more.
EPAD2 series conditioners can be added to either version, allowing you to expand your D300 to more channels, adding slow channels for temperature, as well as DC voltages and currents, in blocks of eight channels.
D300 with SC4 signal conditioner panels: 4 thermocouples, four full or half bridge strain gage, and four voltage inputs. All are isolated to 1500Vrms.
D3PC-4 anD D3PC-8 moDels
The smallest DEWETRON systems ever made are these two:
The D3PC-4 features four IEPE/low-voltage inputs and an advanced counter input.
The D3PC-8 features eight IEPE/low-voltage inputs, two advanced counter inputs, 8 DIO lines ... and you can expand this model to have two CAN BUS interfaces and more digital inputs/counters. You can also sync multiple systems together to make a larger channel count system!
Dewetron ProDUCt SeLeCtIon GUIDe
13
D3PC-4 and D3PC-8 models
There are several basic configurations of the D300, starting with direct inputs from the A/D card, or ISOLATED
SC4 modules, or DIFFERENTAL MDAQ conditioners...
DIRECT INPUTS FROM ORION CARDS, 4-channel instrument
D3PC-4
◙
◙
◙
◙
◙
◙
◙
4 x BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support
24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, anti-aliasing filters
4 different input ranges: ±0.1, ±0.5, ±2, ±10 V
Single-ended or differential configuration, AC (0.15 or 3.4 Hz) or DC coupled
SUB-D-9 connector with 1 synchronous advanced counter / encoder with programmable threshold levels (0 ~ 40 V), input voltage range -35 ~ 60 V, AC/DC coupling, plus an external trigger input (TTL with pull-up)
Includes DS-7-SE acquisition and analysis software
Nothing needs to be added to complete this system (except a display)
D3PC-4 upgrades
rAM-2048-3072
Upgrade the PC RAM from 1
GB to 2 GB or 3 GB
HArD DISK upgrades
Change the HDD from a 500
GB spinning disk to a solid state drive: 32, 64, or 128 GB.
Also, get a spare HDD
Software upgrades
Upgrade the basic version of
DS-7 from -SE to -PROF, or
-DSA.
CAL-orIon-04-nISt-4
NIST traceable calibration data for the ORION-0424-200 card within the D300-4
USB-ArInC or -1553
Add a USB interface for ARINC
429 or MIL-STD-1553 interfaces to your system. Requires software option PLUGIN-
ARINC/1553
D3PC-4 options & accessories
MoB-DISP-17
Ruggedized mobile display with capacitive touchscreen, 17” diag, XGA resolution
0424-CBL-DIG
Mating cable for the digital input connector of the ORION-
0424-200 card, 2 meters, with stripped and tinned leads.
Software options
Add software options like order tracking, sound level meter, modal analysis, balancing, and more.
ACCeLS
Dewetron offers DyTRAN IEPE accelerometers, which are perfectly suited to the D3PC-4
GPS sensor you can add a simple USB
GPS sensor with 1 Hz update rate, or one of our 20/100 Hz
GPS sensors for incredible precision.
VIDeo camera
A common webcam can be connected to the USB port, allowing you to record video in sync with your data
D3PC-4 and -D3PC8 typical applications
BrAKe noISe testing
The four inputs can be used with IEPE microphones to measure SOUND very accurately.
Add a GPS sensor to correlate the data with vehicle speed, position, heading, and other parameters.
14
HUMAn VIBrAtIon testing
Add seat and other accelerometers with the
HUMAN VIBE software option, to study the effects of vibration on human subjects. Ideal for machinery, vehicles, and other applications.
Dewetron ProDUCt SeLeCtIon GUIDe
MoDAL testing
With the synchronous counter input and four
IEPE inputs, the D3PC-4 makes the perfect small channel count modal analysis instrument. Just add DS-OPT-FRF software option and some IEPE accelerometers.
GenerAL PUrPoSe testing
Any basic data acquisition application where you need a small footprint self contained data acquisition instrument with great dynamic specifications (24-bit, 200 kS/s/ch, anti-aliasing)... at a great price point!
DIRECT INPUTS FROM ORION CARDS, 8-channel instrument
D3PC-8
◙
◙
◙
◙
◙
◙
◙
◙
8 analog voltage or ICP (4 / 8 mA) inputs with sensor cable break detection and
TEDS support
24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, anti-aliasing filters
4 different input ranges: ±0.1, ±0.5, ±2, ±10 V
Single-ended or differential configuration, AC or DC coupled
8 synchronous TTL digital I/Os (upgradable to 25V protection via UP-ORION-CTR8)
2 synchronous advanced counter / encoder or 8 digital inputs with programmable threshold levels (0 ~ 40 V), input voltage range -35 to 60 V, AC/DC coupling
Includes DS-7-SE acquisition and analysis software
Nothing needs to be added to complete this system (except a display)
D3PC-8 upgrades
rAM-2048-3072
Upgrade the PC RAM from 1
GB to 2 GB or 3 GB
HArD DISK upgrades
Change the HDD from a 500
GB spinning disk to a solid state drive: 32, 64, or 128 GB.
Also, get a spare HDD
UP-orIon-CAn2
Adds two synchronous highspeed CAN BUS interfaces, including DS-OPT-CAN software option, 2 x DB9’s
D3PC-8 options & accessories
UP-orIon-Ctr8
Upgrade from 8 TTL I/O lines to 25V protected lines, and from 2 advanced counters, to 8 advanced counters
UP-orIon-200-1000-8
Upgrade the A/D card from 200 kS/s max to 1000 kS/s max (@
16-bit instead of 24-bit)
USB-ArInC or -1553
Add a USB interface for ARINC
429 or MIL-STD-1553 interfaces to your system. Requires software option PLUGIN-
ARINC/1553
MoB-DISP-17
Ruggedized mobile display with capacitive touchscreen, 17” diag, XGA resolution
Ctr-CBL-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m.
Software options
Add software options like order tracking, sound level meter, modal analysis, balancing, and more.
ACCeLS
Dewetron offers DyTRAN IEPE accelerometers, which are perfectly suited to the D3PC-4
GPS sensor you can add a simple USB
GPS sensor with 1 Hz update rate, or one of our 20/100 Hz
GPS sensors for incredible precision.
VIDeo camera
A common webcam can be connected to the USB port, allowing you to record video in sync with your data
SoUnD analysis testing
Eight high-dynamic microphone inputs with anti-aliasing filtering makes the D300-8 ideal for all kinds of sound analyses. Great for working in an anechoic chamber or in the field.Add the DS-OPT-SNDLVL software option and IEPE microphones.
MoDAL testing
With the synchronous counter input and eight
IEPE inputs, the D300-8 makes the perfect medium channel count modal analysis instrument. Just add DS-OPT-FRF software option and some IEPE accelerometers.
Dewetron ProDUCt SeLeCtIon GUIDe
15
D300-8 with SC4/MDAQ conditioners
The D300-8 is compatible with 8 channels of ISOLATED SC4 modules, or 16 channels of DIFFERENTIAL
MDAQ conditioners...
WITH MDAQ DIFFERENTIAL or SC4 ISOLATED SIGNAL CONDITIONERS
D300-8
◙
◙
◙
◙
◙
8 channel ORION-0824-200 PCI A/D card built-in
24-bit resolution, simultaneous sampling, 200 kS/s per channel 8 synchronous TTL digital I/Os
2 synchronous TTL counter / encoder or 8 TTL digital inputs
Includes DS-7-SE acquisition and analysis software
Please add any 2.0U-PANEL-MDAQ (or 1.5U-PANEL-MDAQ) plus 2 x MDAQ-SUBs
OR please add 16 channels of SC4 series signal conditioners
(MDAQ and SC4 series conditioners cannot be mixed)
D300-8 upgrades
rAM-2048-3072
Upgrade the PC RAM from 1
GB to 2 GB or 3 GB
HArD DISK upgrades
Change the HDD from a 500
GB spinning disk to a solid state drive: 32, 64, or 128 GB.
Also, get a spare HDD
Software upgrades
Upgrade the basic version of
DS-7 from -SE to -PROF, or
-DSA.
A/D card upgrades
USB-ArInC or -1553
Add a USB interface for ARINC
429 or MIL-STD-1553 interfaces to your system. Requires software option PLUGIN-
ARINC/1553
UP-orIon-200-1000-8
Upgrade the A/D card from 200 kS/s max to 1000 kS/s max (@
16-bit instead of 24-bit)
UP-orIon-CAn2
Adds two synchronous highspeed CAN BUS interfaces, including DS-OPT-CAN software option, 2 x DB9’s
UP-orIon-Ctr8
Upgrade from 8 TTL I/O lines to 25V protected lines, and from 2 advanced counters, to 8 advanced counters
D300-8 options & accessories
MoB-DISP-17
Ruggedized mobile display with capacitive touchscreen, 17” diag, XGA resolution
Ctr-CBL-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m.
Software options
Add software options like order tracking, sound level meter, modal analysis, balancing, and more.
ACCeLS
Dewetron offers DyTRAN IEPE accelerometers, which are perfectly suited to the D3PC-4
GPS sensor you can add a simple USB
GPS sensor with 1 Hz update rate, or one of our 20/100 Hz
GPS sensors for incredible precision.
VIDeo camera
A common webcam can be connected to the USB port, allowing you to record video in sync with your data
16
Dewetron ProDUCt SeLeCtIon GUIDe
FACTORY INSTALLED MDAQ DIFFERENTIAL signal conditioners:
To configure the D300-8 with MDAQ differential signal conditioning, simply order the appropriate
PANEL - either the 2.0U high one which can hold
MDAQs with DSUB connectors (or half DSUB and half BNC), or the 1.5U one which can hold up to 16
BNC connectors.The 1.5U high one, there is a 0.5U high space still available for other PANELS that you might want to have us install.
1.5U-PAnEL-MDAQ-BnC
D300
2.0U-PAnEL-MDAQ
OR...
2.0U-PANEL-MDAQ
Accepts any of our 8 channel MDAQ-SUB modules, regardless of connector type.
When this PANEL is installed, all 8 channels from the standard A/D card are connected to these 8 signal conditioning inputs.
See below for MDAQ-SUB 8-channel conditioners.
1.5U-PANEL-MDAQ-BNC
Accepts any of our 8 channel MDAQ-SUB modules with BNC connectors only.
When this PANEL is installed, all 8 channels from the standard A/D card are connected to these 8 signal conditioning inputs.
See below for MDAQ-SUB 8-channel conditioners.
MDAQ-SUB 8-channel conditioners (choose any ONE of these for the D300-8)
MDAQ-SUB-V200-BnC
8 channel voltage module
16 selectable ranges from
±0.125V to ±200V.
Differential inputs.
CMV ±250 V.
Accuracy ±0.05%.
Bandwidth 300 kHz.
BNC connectors (8)
MDAQ-SUB-V200-D
8 channel voltage
16 selectable ranges from
±0.125V to ±200V.
Differential inputs.
CMV ±250V.
Accuracy ±0.05%.
Bandwidth 300 kHz
±15 VDC fixed sensor supply and programmable 0~12 VDC sensor supply
TEDS support
9-pin DSUB connectors (8)
MDAQ-SUB-ACC-BnC
8 channel IEPE / low-voltage input, selectable ranges of ±10,
5, 2.5, 1.25, 1, 0.5, 0.25 and
0.125 V; sensor power 4 / 8 mA selectable. CMV ±12 V.
AC or DC coupling.
Differential / single-ended (voltage mode only).
Accuracy ±0.05%.
Bandwidth DC to 300 kHz.
Selectable 3.4 Hz high-pass filter. TEDS support.
BNC connectors (8)
Alternate version:
MDAQ-SUB-ACC-BNC-S1
Same as MDAQ-SUB-ACC-
BNC, except that the high-pass filter is 1.6 Hz (typical for structural analysis, modal, and human body vibration)
MDAQ-SUB-ACC-A-BnC
8 channel IEPE / low-voltage input, selectable ranges of ±10,
5, 2.5, 1.25, 1, 0.5, 0.25 and
0.125 V; sensor power 4 / 8 mA selectable. CMV ±12 V.
AC or DC coupling.
Differential (IEPE mode); single-ended (voltage mode).
Accuracy ±0.05%.
Bandwidth DC to 300 kHz.
Selectable 2 programmable high pass filters: 0.16 Hz,
3.4 Hz.
TEDS support.
BNC connectors (8)
MDAQ-SUB-StG-D
8 channel strain / low-voltage input. Modes: full bridge, 1⁄2 bridge, 1⁄4 bridge 120 Ω, 1⁄4 bridge 350 Ω or voltage.
Full bridge sensors 120 Ω to
10 kΩ.
Internal completion for 1⁄2 bridge and 1⁄4 bridge sensors internal 50 kΩ and 100 kΩ shunt resistors
14 selectable ranges from
±0.5 to ±1000 mV/V (@ 5 V excitation)
Voltage mode ranges from ±5 mV to ±10 V
Bandwidth DC to 30 kHz
Excitation voltage from 0~12
VDC. TEDS support
9-pin DSUB connectors (8)
MDAQ-SUB-BrIDGe-D
8 channel bridge / low-voltage input. Modes: full bridge, 1⁄2 bridge
Full bridge sensors 120 Ω to
10 kΩ.
Internal completion for 1⁄2 bridge sensors
AC/DC coupling
14 selectable ranges from
±0.5 to ±1000 mV/V (@ 5 V excitation)
Voltage mode ranges from ±5 mV to ±10 V
Bandwidth DC to 30 kHz
Excitation voltage from 0~12
VDC. TEDS support
9-pin DSUB connectors (8)
Dewetron ProDUCt SeLeCtIon GUIDe
17
D300-16 with SC4/MDAQ conditioners
The D300-16 is compatible with 16 channels of ISOLATED SC4 modules, or 16 channels of DIFFERENTIAL
MDAQ conditioners...
WITH MDAQ DIFFERENTIAL or SC4 ISOLATED SIGNAL CONDITIONERS
D300-16
◙
◙
◙
◙
◙
16 channel ORION-1616-100 PCI A/D card built-in
16-bit resolution, simultaneous sampling, 100 kS/s per channel 8 synchronous TTL digital I/Os
2 synchronous TTL counter / encoder or 8 TTL digital inputs
Includes DS-7-SE acquisition and analysis software
Please add any 2.0U-PANEL-MDAQ (or 1.5U-PANEL-MDAQ) plus 2 x MDAQ-SUBs
OR please add 16 channels of SC4 series signal conditioners
(MDAQ and SC4 series conditioners cannot be mixed)
D300-16 upgrades
rAM-2048-3072
Upgrade the PC RAM from 1
GB to 2 GB or 3 GB
HArD DISK upgrades
Change the HDD from a 500
GB spinning disk to a solid state drive: 32, 64, or 128 GB.
Also, get a spare HDD
UP-orIon-CAn2
Adds two synchronous highspeed CAN BUS interfaces, including DS-OPT-CAN software option, 2 x DB9’s
A/D card upgrades
UP-orIon-Ctr8
Upgrade from 8 TTL I/O lines to 25V protected lines, and from 2 advanced counters, to 8 advanced counters
Software upgrades
Upgrade the basic version of
DS-7 from -SE to -PROF, or
-DSA.
USB-ArInC or -1553
Add a USB interface for ARINC
429 or MIL-STD-1553 interfaces to your system. Requires software option PLUGIN-
ARINC/1553
UP-orIon-16-22
Upgrade the A/D card from
16-bit to 22-bit with anti-aliasing filters (ORION-1622-100).
Max SR is still 100 kS/s/ch
UP-orIon-16-24
Upgrade the A/D card from
16-bit to 24-bit with antialiasing filters (ORION-1624-
200). Max SR increases to 200 kS/s/ch
UP-orIon-100-500
Upgrade the A/D card from max
SR of 100 kS/s/ch to 500 kS/s/ ch (ORION-1616-500). Bit resolution remains at 16-bits.
UP-orIon-100-1000
Upgrade the A/D card from max
SR of 100 kS/s/ch to 1000 kS/s/ ch (ORION-1616-1000). Bit resolution remains at 16-bits.
Dn-orIon-AD16-1000-16
Downgrade the standard A/D card to a multiplexed type, 16 channels, 1000 kS/s (aggregate) max. SR.
D300-16 options & accessories
MoB-DISP-17
Ruggedized mobile display with capacitive touchscreen, 17” diag, XGA resolution
Ctr-CBL-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m.
Software options
Add software options like order tracking, sound level meter, modal analysis, balancing, and more.
ACCeLS
Dewetron offers DyTRAN IEPE accelerometers, which are perfectly suited to the D3PC-4
GPS sensor you can add a simple USB
GPS sensor with 1 Hz update rate, or one of our 20/100 Hz
GPS sensors for incredible precision.
VIDeo camera
A common webcam can be connected to the USB port, allowing you to record video in sync with your data
18
Dewetron ProDUCt SeLeCtIon GUIDe
FACTORY INSTALLED MDAQ DIFFERENTIAL signal conditioners:
To configure the D300-16 with MDAQ differential signal conditioning, simply order the appropriate
PANEL - either the 2.0U high one which can hold
MDAQs with DSUB connectors (or half DSUB and half BNC), or the 1.5U one which can hold up to 16
BNC connectors.The 1.5U high one, there is a 0.5U high space still available for other PANELS that you might want to have us install.
1.5U-PAnEL-MDAQ-BnC
D300
2.0U-PAnEL-MDAQ
OR...
2.0U-PANEL-MDAQ
Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type.
When this PANEL is installed, all 16 channels from the standard A/D card are connected to these 16 signal conditioning inputs.
See below for MDAQ-SUB 8-channel conditioners.
1.5U-PANEL-MDAQ-BNC
Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only.
When this PANEL is installed, all 16 channels from the standard A/D card are connected to these 16 signal conditioning inputs.
See below for MDAQ-SUB 8-channel conditioners.
MDAQ-SUB 8-channel conditioners (choose 2, or 2 of the same one)
MDAQ-SUB-V200-BnC
8 channel voltage module
16 selectable ranges from
±0.125V to ±200V.
Differential inputs.
CMV ±250 V.
Accuracy ±0.05%.
Bandwidth 300 kHz.
BNC connectors (8)
MDAQ-SUB-V200-D
8 channel voltage
16 selectable ranges from
±0.125V to ±200V.
Differential inputs.
CMV ±250V.
Accuracy ±0.05%.
Bandwidth 300 kHz
±15 VDC fixed sensor supply and programmable 0~12 VDC sensor supply
TEDS support
9-pin DSUB connectors (8)
MDAQ-SUB-ACC-BnC
8 channel IEPE / low-voltage input, selectable ranges of ±10,
5, 2.5, 1.25, 1, 0.5, 0.25 and
0.125 V; sensor power 4 / 8 mA selectable. CMV ±12 V.
AC or DC coupling.
Differential / single-ended (voltage mode only).
Accuracy ±0.05%.
Bandwidth DC to 300 kHz.
Selectable 3.4 Hz high-pass filter. TEDS support.
BNC connectors (8)
Alternate version:
MDAQ-SUB-ACC-BNC-S1
Same as MDAQ-SUB-ACC-
BNC, except that the high-pass filter is 1.6 Hz (typical for structural analysis, modal, and human body vibration)
MDAQ-SUB-ACC-A-BnC
8 channel IEPE / low-voltage input, selectable ranges of ±10,
5, 2.5, 1.25, 1, 0.5, 0.25 and
0.125 V; sensor power 4 / 8 mA selectable. CMV ±12 V.
AC or DC coupling.
Differential (IEPE mode); single-ended (voltage mode).
Accuracy ±0.05%.
Bandwidth DC to 300 kHz.
Selectable 2 programmable high pass filters: 0.16 Hz,
3.4 Hz.
TEDS support.
BNC connectors (8)
MDAQ-SUB-StG-D
8 channel strain / low-voltage input. Modes: full bridge, 1⁄2 bridge, 1⁄4 bridge 120 Ω, 1⁄4 bridge 350 Ω or voltage.
Full bridge sensors 120 Ω to
10 kΩ.
Internal completion for 1⁄2 bridge and 1⁄4 bridge sensors internal 50 kΩ and 100 kΩ shunt resistors
14 selectable ranges from
±0.5 to ±1000 mV/V (@ 5 V excitation)
Voltage mode ranges from ±5 mV to ±10 V
Bandwidth DC to 30 kHz
Excitation voltage from 0~12
VDC. TEDS support
9-pin DSUB connectors (8)
MDAQ-SUB-BrIDGe-D
8 channel bridge / low-voltage input. Modes: full bridge, 1⁄2 bridge
Full bridge sensors 120 Ω to
10 kΩ.
Internal completion for 1⁄2 bridge sensors
AC/DC coupling
14 selectable ranges from
±0.5 to ±1000 mV/V (@ 5 V excitation)
Voltage mode ranges from ±5 mV to ±10 V
Bandwidth DC to 30 kHz
Excitation voltage from 0~12
VDC. TEDS support
9-pin DSUB connectors (8)
Dewetron ProDUCt SeLeCtIon GUIDe
19
D300-8 / -16 with SC4 conditioners
RACKS for FACTORY INSTALLED SC4 ISOLATED signal conditioners:
If you want to configure the D300-16 with SC4 isolated signal conditioning, simply select any four of the SC4 conditioners, which include the 0.5U high panel that the connectors are mounted on, as well as the conditioners that are installed inside the system.
You can choose any combination of SC4 modules, including all four the same, or all different, etc. Most
SC4 conditioners are isolated to 1500V RMS.
0.5U PAnEL SLOT 1
0.5U PAnEL SLOT 2
0.5U PAnEL SLOT 3
0.5U PAnEL SLOT 4
D300
SC4 series ISOLATED 4-channel conditioners - choose any combination of four
LOW VOLTAGE
Analog input channels
Full scale input range
Bandwidth (-3 dB point)
CMV (isolation)
CMR (50 or 60 Hz)
NMR
Accuracy
Linearity
Input protection
Output protection
Input resistance
Connectors:
SC4-10mV-BNC SC4-100mV-BNC SC4-1V-BNC
4
±10 mV
10 kHz
4
±100 mV
10 kHz
4
±1 V
10 kHz
1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1)
100 dB 100 dB 100 dB
(–3 dB at 10 kHz) 120 dB per decade above 10kHz
±0.03% span ±0.03% span
±0.01% span
240 Vrms max.
±0.01% span
240 Vrms max.
Continuous short to ground
Normal 200 MΩ, Power off: 40 kΩ, Overload:
40 kΩ
Continuous short to ground
Normal 200 MΩ, Power off: 40 kΩ, Overload:
40 kΩ
Four insulated BNC input connectors on a 0.5U panel
±0.03% span
±0.01% span
240 Vrms max.
Continuous short to ground
Normal 200 MΩ, Power off: 40 kΩ, Overload:
40 kΩ
SC4-10V-BNC
4
±10 V
10 kHz
100 dB
±0.03% span
±0.01% span
240 Vrms max.
Continuous short to ground
Normal/Power off/
Overload: 650 kΩ minimum
SC4-20V-BNC
4
±20 V
10 kHz
100 dB
±0.03% span
±0.01% span
240 Vrms max.
Continuous short to ground
Normal/Power off/
Overload: 650 kΩ minimum
SC4-40V-BNC
4
±40 V
10 kHz
100 dB
±0.03% span
±0.01% span
240 Vrms max.
Continuous short to ground
Normal/Power off/
Overload: 650 kΩ minimum
HIGH VOLTAGE
Analog input channels
Full scale input range
Bandwidth (-3 dB point)
CMV (isolation)
CMR (50 or 60 Hz)
NMR
Accuracy
Linearity
Input protection
Output protection
Input resistance
Connectors:
SC4-100V-B
4
±100 V
SC4-200V-B
4
±200 V
SC4-400V-B
4
±400 V
10 kHz 10 kHz 10 kHz
1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1)
100 dB 100 dB 100 dB
(–3 dB at 10 kHz) 120 dB per decade above 10kHz
±0.03% span
±0.01% span
240 Vrms max.
±0.03% span
±0.01% span
240 Vrms max.
±0.03% span
±0.01% span
240 Vrms max.
Continuous short to ground
Normal 200 MΩ, Power off: 40 kΩ, Overload:
40 kΩ
Continuous short to ground
Normal 200 MΩ, Power off: 40 kΩ, Overload:
40 kΩ
Continuous short to ground
Normal 200 MΩ, Power off: 40 kΩ, Overload:
40 kΩ
Four insulated banana jack input connectors on a 0.5U panel
SC4-1000V-B
4
±1000 V
10 kHz
100 dB
±0.03% span
±0.01% span
240 Vrms max.
Continuous short to ground
Normal/Power off/
Overload: 650 kΩ minimum
NOTE - WHEN SC4 HIGH VOLTAGE MODULES ARE USED, THE D300-16 IS LIMITED TO 8 DyNAMIC INPUT CHANNELS.
20
Dewetron ProDUCt SeLeCtIon GUIDe
RTD
Analog input channels
Linearization
Full scale range:
Sensor compatibility
Wiring modes
Bandwidth (-3 dB point)
CMV (isolation)
NMR
Accuracy
Input protection
Connectors:
SC4-RTD-P100-
2W3W
4
Fully linearized
SC4-RTD-P100-
4W
4
Fully linearized
-100°C to +200°C
100 Ω Platinum RTD
2 and 3-wire configurations only
4 Hz
-100°C to +200°C
100 Ω Platinum RTD
4-wire configuration only
4 Hz
1500 Vrms maximum continuous (transient according to
ANSI/IEEE C37.90.1)
95 dB at 60 Hz, 90 dB at 50 Hz
±0.18°C ±0.18°C
240 Vrms max.
240 Vrms max.
Four insulated DB9 input connectors on a 0.5U panel
THERMOCOUPLES
Analog input channels
Bandwidth (-3 dB point)
CMV (isolation)
Linearization
NMR
Accuracy
Input protection
Connectors:
SC4-TH-J SC4-TH-k SC4-TH-T
4
4 Hz
4
4 Hz
4
4 Hz
1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1)
Fully linearized with automatic CJC
95 dB at 60 Hz, 90 dB at 50 Hz
±0.08% (±0.61°C)
240 Vrms max.
±0.08% (±0.61°C)
240 Vrms max.
±0.08% (±0.61°C)
240 Vrms max.
Four insulated miniature thermocouple input connectors on a 0.5U panel
BRIDGE/STRAIN
Analog input channels
Bridge mode
Full scale range:
Excitation Voltage
Sensitivity
Bandwidth (-3 dB point)
CMV (isolation)
Linearity
NMR
Accuracy
Input protection
Output protection
Connectors:
SC4-BRF-3V-
3mV
4
FULL bridge
SC4-BRF-10V-
2mV
4
FULL bridge
SC4-BRH-3V-
3mV
4
HALF bridge
100 Ω to 10 kΩ
3 V
3 mV/V
10 kHz
300 Ω to 10 kΩ
10 V
2 mV/V
10 kHz
100 Ω to 10 kΩ
3 V
3 mV/V
10 kHz
1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1)
±0.01% Span ±0.01% Span ±0.01% Span
120 dB per decade above 10kHz
±0.03% Span ±0.03% Span
240 Vrms max.
240 Vrms max.
Continuous short to ground
Continuous short to ground
Four insulated DB9 input connectors on a 0.5U panel
±0.03% Span
240 Vrms max.
Continuous short to ground
SC4-BRH-10V-
2mV
HALF bridge
300 Ω to 10 kΩ
10 V
3 mV/V
10 kHz
±0.01% Span
±0.03% Span
240 Vrms max.
Continuous short to ground
D300-16 typical applications
CURRENT
Analog input channels
Full scale range:
Bandwidth (-3 dB point)
CMV (isolation)
NMR
Accuracy
Input protection
Connectors:
4
SC4-LA-4-20mA
4 - 20 mA
4 Hz
1500 Vrms maximum continuous (transient according to ANSI/IEEE
C37.90.1)
95dB at 60Hz, 90dB at
50Hz
±0.03% Span
240 Vrms max.
Four insulated DB9 input connectors on a 0.5U panel
VeHICLe / CAn / GPS testing
The 16 inputs can be configured with every kind of sensor: strain, accel, voltage, current, temperature, and more. Add two CAN BUS interfaces to add vehicle data, and a GPS sensor to record vehicle speed, position, heading, and other parameters.
BUrn-In and LIFe-CYCLe testing
The D300-16 is versatile enough to handle just about any data acquisition application, including factory burn-inm HALT and HASS testing, of satellite components, vehicle parts, motors and turbines, manufacturing equipment, and more.
SHoCK reSPonSe SPeCtrUM testing
With its 16 dynamic IEPE inputs, the D300-
16 makes a great SRS instrument. Configure your inputs for charge, IEPE, or strain gages, voltages, and more. Get the UP-ORION-16-24 upgrade, the DS-OPT-SRS software option, and your sensors.
GenerAL PUrPoSe testing
Any basic data acquisition application where you need a small footprint self contained data acquisition instrument with great dynamic specifications (24-bit, 200 kS/s/ch, anti-aliasing)... at a great price point!
Dewetron ProDUCt SeLeCtIon GUIDe
21
D300 expansion guide
Expansion via analog cable
A very popular way of expanding the analog inputs is to upgrade the ORION card from 16 to 32 dynamic channels, then connect external signal conditioning amplifiers via an analog cable.
Simply upgrade the D300-16 to have 32 A/D channels inside via either the UP-ORION-16-22-32
(22-bit @ 100 kS/s/ch) or the UP-ORION-1616-32 option (16-bit @ 100 kS/s/ch), then add an external 16 channel conditioning chassis and cable. Choose from MDAQ or DAQ / HSI series plug-in conditioners.
DEWE-31-16 or
DEWE-30-16 expansion chassis
32-channel ORION card in D300-16 mainframe
A
NAL
OG SIGNAL
S
P
OW
ER S
UPPLY
AC (optional DC) power supply
Expansion chassis
Amplifier slots
MDAQ channels
A/D converter
Power supply (standard)
Dimensions (WxDxH)
Weight
DEWE-30-16 DEWE-31-16
16
--
--
8 or 16
(Connects to the A/D card in the main system - there is no A/D converter inside any DEWE-30 or DEWE-31 chassis)
120/230 VAC 50/60 Hz DC from the mainframe or via
AC/DC adapter
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
4 kg (9 lbs)
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in
1.6 kg (3.5 lbs)
D3PC with PCI bridge card inside
PCI HOST
SyNC
AC (optional DC) power supply
Expansion via PCI bridge
The PCI expansion is an alternative especially if high channel count is needed. The best mainframe to use is the D3PC computer chassis, which has no inputs of its own, but it will contain the PCI bridge card and run the whole system. The DEWE-50, DEWE-51 and DEWE-52 ADC racks can be connected by a 1m PCI cables. ORION series cards are installed inside the DEWE-5x unit and you simply have to select the suitable signal amplifiers for your needs.
In this way, the D3PC can serve as the host of a system with dozens, hundreds, or even more than 1000 dynamic input channels!
Important notice: Each DEWE-50/51/52 chassis must be equipped with
ORION-SYNC option.
DEWE-52-PCI-3216
Expansion chassis
Amplifier slots
MDAQ channels
ORION card slots
Power supply (standard)
Dimensions (WxDxH)
Weight
22
DEWE-50-PCI-32
32
--
3
120/230 VAC 50/60 Hz
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
10 kg (22 lbs)
DEWE-50-PCI-64
64
--
7
120/230 VAC 50/60 Hz
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in.
15 kg (33 lbs)
Dewetron ProDUCt SeLeCtIon GUIDe
DEWE-51-PCI-32
--
Up to 64
7
120/230 VAC 50/60 Hz
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
6 kg (13 lbs)
DEWE-51-PCI-128
--
Up to 128
13
120/230 VAC 50/60 Hz
408 x 287 x 267 mm
16.1 x 11.3 x 10.5 in
9 kg (20 lbs)
DEWE-52-PCI-3216
16
Up to 32
7
120/230 VAC 50/60 Hz
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
9 kg (20 lbs)
Expansion via Ethernet
The NET expansion is a fantastic way to combine two or more DEWE instruments to one multichannel system. Each instrument must have installed hardware option ORION-
SYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First is a simple cable connection for distances up to
200 m, second one is GPS- or DEWE-CLOCK which is useful for long distances when a cable connection is not possible. DS-OPT-
NET software offers full remote setup, online data transfer up to the limit of the network connection and offline data transfer between the instruments.
User tip: The NET expansion also distributes the data processing load among multiple computers, each of which can store data at full speed.
D300-16
D3PC-8
SyNC
ETHERNET
D3PC-8
D300-16
GPS-CLOCk
SyNC
ETHERN
ET
0.000 ms
GPS-CLOCk
SyNC
Specifications
Specification
Direct Voltage / IEPE inputs:
MDAQ-SUB positions
SC4 positions
D300 series
D3PC-4: 4 channels
D3PC-8: 8 channels
D300-16: 2 positions (16 channels)
D300-16: 4 positions (16 channels)
Main system
Total PCI slots
Hard disk
Data throughput to disk
Power supply
Processor
RAM
Computer interfaces:
Operating system
Dimensions (W x D x H)
(without bumpers)
1 x half-length PCI slots
500 GB standard removable drive (optional solid state drive)
50 MB/s typical; faster rates available with the additional of an internal
RAID controller and/or additional drives
9~29 VDC. Includes external AC/DC power adapter for operating the system from 120/240 VAC 50/60 Hz.
Intel Core2Duo 2.0 GHz CPU, on a standard industrial grade MiniITX mainboard
2 GB (expandable to 4 GB)
2 x Gb ethernet; 4 x USB 2.0; 1 x RS232 serial (DB9 connector)
Microsoft Windows7 32-bit included (64-bit available Q4 2012)
D3PC: 8.5 x 4.75 x 10.78 (216 x 121 x 274 mm)
D300: 14.5 x 4.75 x 10.78 (368 x 121 x 274 mm)
Weight D3PC models: 4 kg typical (~9 lbs)
D300-16 models: 5.5 kg typical (~12 lbs)
Environmental specifications
Operating temperature
Humdity
Vibration
Shock
-20 to 50°C (0 to 45°C with batteries installed) (storage temp -20 to 60C)
10 to 80% non-condensing, 5 to 95% relative humidity
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
MIL-STD-810F, EN 60068-2-27
Data acquisition specifications
D3PC-4 model: Includes ORION-0424-200 A/D card (IEPE signal conditioning included)
4 different input ranges: ±0.1V, ±0.5V, ±2V, ±10V
4 BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support
24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, antialiasing filters
Single-ended or differential inputs, software selectable
AC (0.15 or 3.4 Hz) or DC coupled
One synchronous advanced counter/encoder with programmable threshold levels (0 ~ 40 V), input voltage range -35 ~ 60 V, DB9 connector
External trigger input
D3PC-8 model:
D300-16 model:
D300-16 A/D card upgrades:
Data acquisition software:
Software upgrades available:
D300-16 EPAD interface:
Includes ORION-0824-200 A/D card (IEPE signal conditioning included)
4 different input ranges: ±0.1V, ±0.5V, ±2V, ±10V
8 BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support
24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, antialiasing filters
Single-ended or differential inputs, software selectable
AC (0.15 or 3.4 Hz) or DC coupled
Two synchronous advanced counters/encoders with programmable threshold levels (0 ~ 40 V), input voltage range -35 ~ 60 V, LEMO connectors
8 synchronous TTL digital I/Os and one external trigger input, DB37
Includes ORION-1616-100 A/D card (requires signal conditioning)
100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100)
Please order your choice of either 4 x SC4 conditioners, or MDAQ PANEL and SUB modules to complete this system.
Upgrades to faster cards, and higher resolution cards available
UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing
UP-ORION-16-22-32: upgrade to 22-bit with 102.4 kS/s/ch and from 16 to
32 channels
UP-ORION-16-24: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing
UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch
UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch
UP-ORION-1616-3216: upgrade from 16 channels to 32 channels (100 kS/s/ch maximum sample rate @ 16-bit resolution)
DS-7-SE is included as standard
To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS
Standard LEMO 4-pin connector. EPAD2 modules are daisy-chainable
External channel expansion
Low-speed channel expansion: Up to 16 EPAD2 modules can be connected to the EPAD connector, adding up to 128 channels of low-speed thermocouple, voltage, RTD, and current inputs, in blocks of eight channels
Expansion via analog cable:
Expansion via PCI bridge:
Expansion via ethernet:
D300-16 only - first upgrade the internal A/D card to have 32 channels:
UP-ORION-1616-3216 upgrades the std card from 16 to 32 channels
UP-ORION-16-22-32 upgrades the std card from 16 to 32 channels, and from 16-bit to 22-bit resolution with anti-aliasing filtering
D300-16 only - then add an external 16 channel chassis of conditioning
(see optional expansion chassis on this page)
Up to 256 total dynamic analog input channels (with PCI bridge card installed inside the D3PC, and external DEWE-50/51 chassis connected.
Up to 2000 total dynamic analog input channels (with SyNC option for local connections, or IRIG/GPS sync for remote connections, and multiple remote DEWE systems synchronized via DS-OPT-NET software option.
Dewetron ProDUCt SeLeCtIon GUIDe
23
Dewe-3210 with 16 MDAQ channels
Dewe-3210 with
8 DAQ modules
DEWE-3210 series
www.dewamerica.com/Products/DEWE-3210
OVERVIEw
The DEWE-3210 is our most popular PORTABLE data acquisition instrument. It has a 16-channel A/D card installed already, with 100 kS/s/ch simultaneous sampling and 16-bit resolution. Our DS-7 software is also included!
Simply choose between our plugin modules or factory installed MDAQ signal conditioners in order to complete your system.
If you configure it with 8 of our plugin modules, the other 8 channels are available on a connector so that you can use one of our external expansion boxes.
The factory installed MDAQ conditioners provide all 16 channels with conditioners right on the side panel.
Digital inputs are counters are standard. You can add many options, including interfaces for CAN BUS,
ARINC, 1553, VIDEO, IRIG, GPS, cameras, and more.
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
16 channel, 100 kS/s/ch simultaneous sampling A/D card card inside
DS-7-SE software included
Choose from DAQ or MDAQ series signal conditioners
500 GB removable HDD
Built-in TOUCHSCREEN display
17” display, 1280x1024 resolution keyboard built-in below the screen
Battery power - runs 2-3 hours without any external power connected
Batteries are hot-swappable - even during measurement
Ruggedized construction, MIL-STD, EN-
STD, and more
Made in USA
Full year warranty
24
Dewetron ProDUCt SeLeCtIon GUIDe
◙
◙
◙
◙
◙
◙
◙
aPPliCations
◙ General purpose data acquisition
◙ Field service and field test applications
Energy test
Vehicle test
Aircraft tests
Railcar test
Noise & vibration
All kinds of trouble-shooting
Every kind of mechanical and structural test
BUilt to last
We build the DEWE-3210 in the same USA factory where Dewetron’s BATTERY POWER technology was invented back in 2004. After delivering hundreds of instruments, and then doing the maintenance and repairs on them, we know what breaks, and what doesn’t. This experience feeds directly back into the next revision, ensuring that each one gets better and more reliable than the one before. That’s the continuous improvement that ensures your investment in a DEWE-3210 is a good one, and for years to come.
the computer connections are protected behind a metal door
real PortaBiltY
The DEWE-3210 features our BATTERY POWER technology as a standard feature. You get about an hour from each hot-swappable battery (two are included, a third is optional). Even if you don’t need battery operation per se, what a great UPS this makes! If power is lost for whatever reason, the system keeps running without interruption, instantly switching from AC to battery power, and back again, as needed.
Dewetron ProDUCt SeLeCtIon GUIDe
25
DEWE-3210 configuration guide
To complete your DEWE-3210, you just need to choose the signal conditioners that you want. There are two basic choices: plug-in DAQ/HSI modules, or factory installed MDAQ conditioners. Choose plug-in modules when you need single channel modularity and ISOLATION. Choose MDAQ conditioners when differential inputs are OK, and you want as many channels as possible on the mainframe.
The DEWE-3210 has one 2.0U PANEL space on its left side: phoose ONE of these PANELS to be factory installed, then choose the conditioners that you want in it!
RACKS for PLUG-IN Isolated signal conditioners:
2.0U-PANEL-RACK8
Accepts up to 8 of our plugin DAQ and PAD series signal conditioning modules.
(Compatible also with all HSI modules, except that it limits their bandwidth to 300 kHz)
When this RACk is installed, the other 8 A/D channels will be brought to a nearby connector so that you can easily attach one of our expansion RACkS and utilize the other
8 dynamic input channels.
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
OR...
2.0U-PANEL-RACK8-HSI
Accepts up to 8 of our plugin HSI series signal conditioning modules. Also compatible with most DAQ and PAD series modules (not compatible with DAQP-CHARGE-A and
DAQP-FREQ-A and other very old DAQ modules).
When this RACk is installed, the other 8 A/D channels will be brought to a nearby connector so that you can easily attach one of our expansion RACkS and utilize the other
8 dynamic input channels.
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
OR...
RACKS for FACTORY INSTALLED differential signal conditioners:
2.0U-PANEL-MDAQ
Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type.
When this RACk is installed, all 16 channels from the standard A/D card are connected to these 16 signal conditioning inputs.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
OR...
1.5U-PANEL-MDAQ-BNC
Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only.
When this RACk is installed, all 16 channels from the standard A/D card are connected to these 16 signal conditioning inputs.
Note: an additional 0.5U space is available for small connector panels to be installed here!
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
26
Dewetron ProDUCt SeLeCtIon GUIDe
2.0U-PAnEL-RACK8
2.0U-PAnEL-MDAQ
1.5U-PAnEL-MDAQ-BnC
FACTORY INSTALLED upgrades available at the time of ordering:
UP-ORION-CAN2
Adds two high speed CAN BUS interfaces, the DB9 connectors, and the software option inside DS-7.
UP-ORION-CTR8
Upgrades the digital inputs to 8 TTL digital inputs protected up to 25 VDC, and 8 counter/encoder inputs with programmable threshold (0-40VDC) and -35 to 60V range, AC/DC coupling. Includes DB37 connector and mate.
UP-ORION-16-22
Upgrade the A/D card to 22-bit resolution with anti-aliasing filtering, with 100 kS/s/ch max sample rate.
UP-ORION-16-24
Upgrade the A/D card to 24-bit resolution with anti-aliasing filtering, with 200 kS/s/ch max sample rate.
UP-ORION-100-500
UP-ORION-100-1000
DN-ORION-AD16-1000-16
Upgrade the A/D card to 500 kS/s/ch max sample rate.
Upgrade the A/D card to 1000 kS/s/ch max sample rate.
Downgrade the A/D card to multiplexed 16-bit card with
1MS/s/ aggregate sample rate, 2 simple counters, and 8
TTL digital I/O lines.
ORION-SYNC
Installs a SyNC interface and in/out RJ45 connectors for multi-system synchronization
3210-DC-POWER
Upgrades the power system to run from a wider DC range:6 to 30 VDC max. (instead of 18-24 VDC max).
RAM-2048-3072
RAM-2048-4096
HDD-SDD-32
Upgrades the computer RAM from 2 GB to 3 GB
Upgrades the computer RAM from 2 GB to 4 GB
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 32 GB size
HDD-SDD-64
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 64 GB size
HDD-SDD-128
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 128 GB size
HDD-SDD-256
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 256 GB size
There are other options and upgrades available - please consult your DEWETRON representative for the latest information, and for pricing.
Dewetron ProDUCt SeLeCtIon GUIDe
27
DEWE-3210 expansion guide
Expansion via analog cable
A very popular way of expanding the analog inputs is to install more ORION cards into the instrument and connect external signal conditioning amplifiers via analog cables. Each
DEWE-3210 instrument has two spare PCI-slots which can be used to install additional ORION cards. Select a suitable external DEWE-30 or
DEWE-31 series signal conditioning rack, the required amplifiers and directly connect the analog outputs to the ORION cards by analog signal cables.
DEWE-31-12
DEWE-ORION card in main system
A
NA
LOG
SIGNALS
P
OW
ER S
UPPLY AC (optional DC) power supply
Expansion chassis
Amplifier slots
MDAQ channels
A/D converter
Power supply (standard)
Dimensions (WxDxH)
Weight
DEWE-30-8 DEWE-30-16 DEWE-30-32 DEWE-31-16
8
--
16
--
32
--
--
8 or 16
(Connects to the A/D card in the main system - there is no A/D converter inside any DEWE-30 or DEWE-31 chassis)
120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
4 kg (9 lbs)
435 x 223 x 245 mm
16.1 x 13/4 x 7.9 in
7 kg (15 lbs)
DC from the mainframe or via
AC/DC adapter
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in
1.6 kg (3.5 lbs)
DEWE-31-32
--
8, 16, 24 or 32
120/230 VAC 50/60 Hz
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
4 kg (9 lbs)
DEWE-3210
DEWE-52-PCI-3216
PCI HOST
SyNC
AC (optional DC) power supply
Expansion via PCI bridge
The PCI expansion is an alternative especially if high channel count is needed. When using an expansion only one PCI slot is occupied in the
DEWE-3210 instrument by a PCI-HOST-CARD. The DEWE-50, DEWE-51 and DEWE-52 ADC racks can be connected by a 1m PCI cable. The
ORION cards are installed inside the DEWE-5x unit and you simply have to select the suitable signal amplifiers for your needs.
Important notice: The DEWE-3210 and the DEWE-5x must be equipped with ORION-SYNC option.
User tip: with an additional ECARD-34 or 54 the DEWE-5x also can be used as an independent system in combination with a laptop computer.
Expansion chassis
Amplifier slots
MDAQ channels
ORION card slots
Power supply (standard)
Dimensions (WxDxH)
Weight
28
DEWE-50-PCI-32
32
--
3
120/230 VAC 50/60 Hz
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
10 kg (22 lbs)
DEWE-50-PCI-64
64
--
7
120/230 VAC 50/60 Hz
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in.
15 kg (33 lbs)
Dewetron ProDUCt SeLeCtIon GUIDe
DEWE-51-PCI-32
--
Up to 64
7
120/230 VAC 50/60 Hz
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
6 kg (13 lbs)
DEWE-51-PCI-128
--
Up to 128
13
120/230 VAC 50/60 Hz
408 x 287 x 267 mm
16.1 x 11.3 x 10.5 in
9 kg (20 lbs)
DEWE-52-PCI-3216
16
Up to 32
7
120/230 VAC 50/60 Hz
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
9 kg (20 lbs)
Expansion via Ethernet
The NET expansion is a fantastic way to combine two or more DEWE instruments to one multichannel system. Each instrument must have installed hardware option ORION-
SYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First is a simple cable connection for distances up to 200 m, second one is GPS- or IRIG-CLOCK which is useful for long distances when a cable connection is not possible. DS-OPT-
NET software offers full remote setup, online data transfer up to the limit of the network connection and offline data transfer between the instruments.
User tip: The NET expansion also distributes the data processing load among multiple computers, each of which can store data at full speed.
DEWE-3210
DEWE-3210
SyNC
ETHERNET
DEWE-3210
GPS-CLOCk
SyNC
ETHERN
ET
0.000 ms
DEWE-3050
GPS-CLOCk
SyNC
Specifications
Specification
Slots for DAQ/PAD/HSI modules
MDAQ-SUB positions
DEWE-3210
8 with 2.0U-PANEL-DAQ or -HSI
2 with 2.0U-PANEL-MDAQ or 1.5U-PANEL-MDAQ-BNC
Main system
Total PCI slots
Hard disk
Data throughput to disk
Power supply
Display
Processor
RAM
Ethernet
USB
RS232 serial interface
Optical drive
Operating system
Dimensions (W x D x H)
Weight
Environmental specifications
Operating temperature
Humdity
Vibration
3 x half-length PCI slots
500 GB standard removable drive (optional solid state drive)
50 MB/s typical; faster rates available with the additional of an internal
RAID controller and/or additional drives
Hot-swappable batteries, operates from 18~24 VDC. Includes DPS-2410 external AC/DC power adapter for recharging the batteries and operating the system from AC mains.
17” SXGA display, 1280 x 1024 px, with standard resistive touchscreen
Intel Core2Duo 2.0 GHz CPU, on a standard industrial grade MiniITX mainboard
2 GB (expandable to 4 GB)
2 x Gb ethernet interfaces
Four x USB 2.0 interfaces
One serial interface (DB9 connector)
DVD+-CD-RW drive built-in. CD burning capability included
Microsoft Windows7 32-bit included
425 x 340 x 191 mm (16.7 x 13.4 x 7.5 in.)
10 kg typical (22 lbs)
-20 to 50C (0 to 45C with batteries installed) (storage temp -20 to 60C)
10 to 80% non-condensing, 5 to 95% relative humidity
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock MIL-STD-810F, EN 60068-2-27
Data acquisition specifications
Standard A/D card specifications: 100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100)
Upgrades to faster cards, and higher resolution cards available
Available A/D card upgrades:
Data acquisition software:
Software upgrades available:
Analog inputs:
UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing
UP-ORION-16-22: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing
UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch
UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch
DS-7-SE is included as standard
To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS
16, according to the installed DAQ, PAD, HSI, or MDAQ signal conditioners
Signal conditioning available: Isolated/differential conditioners for low voltage, high voltage, strain, bridge, pressure, thermocouples, RTDs, IEPE, charge
Standard LEMO 4-pin connector, right side panel EPAD interface:
Computer upgrades
RAM upgrades:
Hard disk drive upgrade:
Filtering upgrades:
Increase from 2 to 3 GB or 4 GB
Add an internal drive, or increase the size of the removable drive, or convert the removable drive to a solid state drive
DAQ/HSI modules have filters built-in
MDAQ-FILT options available for MDAQ systems
Popular interfaces
CAN BUS interfaces:
Time code interface:
VIDEO-FG-4
ARINC-429
UP-ORION-CAN2 adds 2 high-speed synchronous CAN BUS interfaces on
DB9 connectors, and DS-OPT-CAN software option
Adds an internal IRIG or GPS time code interface (does not require a PCI slot)
Adds a four channel VIDEO INPUT PCI card to the system. Four BNCs for analog NTSC video input on the right side panel, allowing four video streams to be recorded in sync with the data
Several different interface cards are available with various numbers of
ARINC 429 transmit and receive channels
MIL-STD-1553 Several different interface cards are available with various numbers of MIL-
STD-1553 transmit and receive channels
External channel expansion
Low-speed channel expansion: Up to 16 EPAD2 modules can be connected to the EPAD connector, adding up to 128 channels of low-speed thermocouple, voltage, RTD, and current inputs, in blocks of eight channels
Expansion via analog cable:
Expansion via PCI bridge:
Expansion via ethernet:
Up to 96 total dynamic analog input channels (with three 32-channel A/D cards installed inside the DEWE-3210, and external DEWE-30/31 chassis connected.
Up to 256 total dynamic analog input channels (with PCI bridge card installed inside the DEWE-3210, and external DEWE-50/51 chassis connected.
Up to 2000 total dynamic analog input channels (with SyNC option for local connections, or IRIG/GPS sync for remote connections, and multiple remote DEWE systems synchronized via DS-OPT-NET software option.
Dewetron ProDUCt SeLeCtIon GUIDe
29
DEWE-3210 ordering guide
Please use the table below to configure your DEWE-3210 system. From this ordering guide, your DEWETRON representative can create a detailed price quote for you.
First, please choose your basic model: deWe-3210
Portable battery-powered data acquisition system
16-bit resolution, simultaneous sampling, 100 kS/s per channel
8 synchronous TTL digital I/Os
2 synchronous TTL counter / encoder or 8 TTL digital inputs
2.0U panel space available for signal conditioners
Choose from plugin DAQ / PAD / HSI series conditioning modules or
MDAQ differential signal conditioning inputs (16 channels) or a combination
2 free PCI slots (3 half length PCI slots inside when any PANEL is installed, 1 is used by the standard A/D card)
EPAD2 connector for optional EPAD2 modules. DS-7-SE software is included
NeXt, please choose the siGNal coNditioNiNG paNel(s) that you Need (Factory iNstalled, see previous paGes For possibilities):
2.0u-paNel-racK8
2.0U Card cage for up to 8 DAQ / HSI / PAD module slots, 300 kHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
2.0u-paNel-racK8-hsi
2.0u-paNel-mdaQ-dsub
2.0U Card cage for up to 8 HSI / DAQ / PAD module slots, 2 MHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
Not compatible with the DAQP-CHARGE-A, DAQP-FREQ-A, and certain older DAQ modules
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where either or both of have 9-pin DSUB connectors.
Please order your choice of MDAQ-SUB-XX-D conditioners separately (2 required).
1.5u-paNel-mdaQ-bNc
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where both have BNC connectors. Please order your choice of MDAQ-SUB-XX-BNC conditioners separately (2 required).
additioNal available coNNector paNels
0.5u-orioN-cNt2-lemo
0.5 U panel with 2 LEMO connectors EGG.1B.307 connected to the 2 counters of an ORION base card, incl. mating connectors
0.5u-ampFleX-poWer-8
0.5 U panel with 8 Binder 712 connectors, 9 V Power supply for PNA-A100 current transducers
0.5u-clamp-dc-poWer-4 0.5 U panel with 4 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
0.5u-clamp-dc-poWer-8 0.5 U panel with 8 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
0.5u-da2-bNc
0.5u-da4-bNc
0.5 U panel with 2 BNC connectors connected to the 2 analog outputs of an AD16-1000-16-OUT2 card
0.5 U panel with 4 BNC connectors connected to the 4 analog outputs of a DA4-1000-16 card
0.5u-da8-bNc
0.5 U panel with 4 BNC connectors connected to the 8 analog outputs of a DA8-1000-16 card
please choose aNy a/d card upGrades that you reQuire (Factory iNstalled oNly): up-orioN-16-22 up-orioN-16-24 up-orioN-100-500
Upgrade the standard 16-channel A/D card from 16-bit resolution to 22-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1622-100). The max. sample rate remains at 100 kS/s/ch.
Upgrade the standard 16-channel A/D card from 16-bit resolution to 24-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1624-200). The max. sample rate increases to 204.8 kS/s/ch.
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 500 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-500).
up-orioN-100-1000 up-orioN-1616-3216 dN-orioN-ad16-1000-16
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 1000 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-1000).
Upgrade the standard 16-channel A/D card from 16 to 32 simultaneously sampled channels (converts from ORION-1616-100 to
ORION-3216-100). The max. sample rate remains at 100 kS/s/ch.
Replaces the standard A/D card from ORION-1616-100 to AD16-1000-16, which provides:
Single ADC multiplexed 16-bit A/D card, 1000 kS/s aggregate max. sample rate (62.5 kS/s/ch max sample rate when all 16 analog channels are recording), 8 TTL digital I/O lines (compatible with DS-7 ALARMS), 2 basic counter inputs.
Note: this card is not compatible with any UP-ORION series options.
Note: if CAN BUS interfaces are desired with this A/D card, please order the PCI-CAN2 card and DS- OPT-CAN software option.
Additional 0.5 panels that can be installed with the 1.5U-panel-MDAQ-BNC only:
0.5U-DA2-BNC
0.5U-AMFLEX-POWER-4
0.5U-DA4-BNC
0.5U-AMFLEX-POWER-8
0.5U-DA8-BNC
0.5U-CLAMP-DC-POWER-4
0.5U-CLAMP-DC-POWER-8
30
Dewetron ProDUCt SeLeCtIon GUIDe
NeXt, please list the siGNal coNditioNers that you Would liKe to have:
There are too many possibilities to list them all here. Please see the separate signal conditioner pages, and select the models that you desire, and their quantities:
daQ modules
300 kHz bandwidth modules: DAQP-HV high voltage, DAQP-LV low voltage, DAQP-STG strain/universal
50 kHz bandwidth modules: DAQP-ACC-A accels (IEPE), DAQP-CHARGE-A accels (charge)
3 kHz bandwidth modules: DAQP-MULTI (bridge/universal, DAQP-THERM universal thermocouple
hsi modules
2 MHz bandwidth modules: HSI-HV high voltage, HSI-LV low voltage
1 MHz bandwidth modules: HSI-STG strain/universal
pad modules
PAD-TH8-P 8-ch thermocouple module, PAD-V8-P 8-ch voltage module
mdaQ-sub amps
300 kHz bandwidth modules: MDAQ-SUB-V200-BNC 8 channel voltage, MDAQ-SUB-ACC(-A) 8 channel accel (IEPE)
30 kHz bandwidth modules: MDAQ-SUB-STG 8 channel strain/universal, MDAQ-SUB-BRIDGE 8 channel bridge/universal
msi adapters
For -STG-D/BRIDGE-D amps: MSI-BR-V-200 voltage, MSI-BR-ACC accel (IEPE), MSI-BR-CHA accel (charge), MSI-BR-RTD temperature (RTD), MSI-BR-TH-J(-K, -T, -C) temperature (thermocouple)
NeXt, please choose aNy hardWare upGrades that you Would liKe (Factory iNstalled, diFFicult or impossible to add later): orioN-syNc hdd-sata-1tb system-ssd-64 hdd-600-ssd-32 hdd-600-ssd-64
Synchronization option for instruments with ORION cards, allows synchronization of PC based instruments or ADC Racks for PCI, all systems must have ORION-xx16 cards. Includes 2 m CAT-5E sync-cable, max. length of the sync-cable can be 50 m, this option is required for each unit which needs synchronization
Adds a 1 TB (1000 GB) standard S-ATA HDD inside the chassis
Additional internal 64 GB flash disk for Windows and DS7, the removable hard disk remains
Upgrade to 32 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
Upgrade to 64 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
hdd-600-ssd-128 ram-2048-3072 mob-disp-17
Upgrade to 128 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
Upgrade the standard 2 GB RAM to 3 GB RAM>
NeXt, please choose aNy soFtWare upGrades that you Would liKe (Factory iNstalled, but caN be added later): ds-up-se-proF
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 16 channels of A/D are installed)
ds-up-se-dsa
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 64 channels of A/D are installed)
NeXt, please choose aNy accessories that you Would liKe:
Mobile high brightness 17” display with capacitive touchscreen, 1280x1024 pixels, USB touchscreen interface + DVI + VGA interfaces
Wide range DC power input (12V/24V, up to 5A), INCLUDES: #1/4-20 cup mounting points on top and sides; standard VESA100 mounting positions on the rear panel; two USB 2.0 interfaces on the side; 1 m VGA cable with DVI adapter; 2.5 m USB cable, 1 m power cable, FGG.1B.302.CLA LEMO to banana plugs; AC/DC adapter for lab usage.
disp-17-opt hdd-rem-bacKup
Accessory set for MOB-DISP-17 for use inside vehicles, includes: two high-grade suction cups; 3 m VGA cable; 3 m USB cable; 1 meter power cable (LEMO to cigarette lighter plug)
Spare hard disk, installed inside removable drive carrier. If ordered with the system, we will clone the removable HDD onto this HDD, so that it can be used to restore the system in the event of HDD failure.
ctr-cbl-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m
NeXt, please choose aNy iNterFaces that you Would liKe to have iNstalled: ariNc or 1553 pcm interface
FG-video-4 time code
Please select from the separate lists
Please select from the separate lists
4 input NTSC video frame grabber. Requires one PCI or PCIe slot within the system.
Please select from the separate lists
other optioNs aNd services available: cal-daQ/mdaQ-Nist
Calibration of any single DAQ / PAD/HSI conditioner, or any MDAQ-SUB series 8-channel signal conditioning module. Includes a
NIST traceable CAL report generated by our Fluke MET/CAL system. This calibration includes the MDAQ-BASE card which holds two
MDAQ-SUB cards. The A/D card and MDAQ modules are calibrated together under our procedure. Dewetron’s USA cal lab is ANSI/
NCSL Z540-1 compliant. This calibration is valid for one year.
WarraNty-eXt-12-24
WarraNty-eXt-12-36
Warranty extension, 6 % of total system price for the second year, hardware only. Must be ordered with the initial purchase order
Warranty extension, 14 % of total system price for a total of 3 years, hardware only. Must be ordered with the initial purchase order
Dewetron ProDUCt SeLeCtIon GUIDe
31
Dewe-3050 configured with up to 32 plug-in signal conditioners (DAQ / PAD / HSI series)
Dewe-3050 with removable CAPACItIVe 17” touchscreen
DEWE-3050 series
www.dewamerica.com/Products/DEWE-3050
OVERVIEw
The DEWE-3050 is a unique model, absolutely full of
“firsts” in a DEWETRON “all in one” portable/benchtop data acquisition instrument:
It is the only one that can hold 32 DAQ/PAD/HSI modules. It is the only one which can hold 96 MDAQ channels and battery power. It’s the only one with battery power and the AC/DC adapter built inside. It’s the only one with a capacitive touchscreen ... and it’s the only DEWE which has a removable display!
The 5 PCI slots inside makes it possible to have a lot of analog inputs PLUS data bus interfaces, like
ARINC, CAN, 1553, and more. It comes with a 16 channel ORION card with 100 kS/s/ch max sample rate and DS-7-SE acquisition and analysis software.
Just choose your signal conditioning and any upgrades / add-ons that you would like to complete the system.
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
16 channel, 100 kS/s/ch simultaneous sampling A/D card card inside
Expandable to 96 FAST internal channels!
DS-7-SE software included
Choose from DAQ, PAD, HSI, MDAQ and MPAD series signal conditioners in countless combinations
Two removable HDDs - one for data and one for the OS and applications
Removable TOUCHSCREEN display
CAPACITIVE touchscreen supports multitouch applications
17” display, high resolution keyboard stores behind the display when not in use
Battery power - runs 2-3 hours without any external power connected
Ruggedized construction, MIL-STD, EN-
STD, and more
Made in USA
Full year warranty
32
Dewetron ProDUCt SeLeCtIon GUIDe
◙
◙
◙
◙
◙
◙
◙
aPPliCations
◙ General purpose data acquisition
◙ Field service and field test applications
Energy test
Vehicle test
Aircraft tests
Railcar test
Noise & vibration
All kinds of trouble-shooting
Every kind of mechanical and structural test
UnPreCenteD Channel CoUnts
The DEWE-3050 is the only “all in one” Dewetron model that can be configured with 32 slots for any of our plug-in modules in the DAQ, PAD, and HSI series.
If you prefer MDAQ conditioning, we can configure the rear panel with up to 96 channels (12 x 8 channel MDAQ-SUB conditioners).
A combination of 16 plug-in and up to 64 MDAQ is also easy to do!
No other Dewetron “all in one” system can be configured in so many ways.
Dewe-3050 configured with 16 plug-in signal conditioners (DAQ / PAD / HSI series) plus 32 MDAQ series channels. there is still room for 32 more MDAQ channels - or other function PAneLS
BatterY anD aC Power stanDarD
The DEWE-3050 is the only Dewetron instrument that has direct AC power input AND our hot-swappable battery power technology. No external AC/DC adapter is needed with the DEWE-3050.
If power is lost for whatever reason, the system keeps running without interruption, instantly switching from
AC to battery power, and back again, as needed.
Even if you don’t need battery power, what a great
UPS our battery system makes.
Dewetron ProDUCt SeLeCtIon GUIDe
33
DEWE-3050 configuration guide
To complete your DEWE-3050, you just need to choose the signal conditioners that you want. There are two basic choices: plug-in DAQ/HSI modules, or factory installed MDAQ conditioners. Choose plug-in modules when you need single channel modularity and ISOLATION. Choose MDAQ conditioners when differential inputs are OK, and you want as many channels as possible on the mainframe.
The DEWE-3050 can accept a huge number and variety of signal conditioners on its rear panel - choose the ones that you want and we’ll do the rest.
Please refer to the graphic here to see what can be installed on the rear panel.
Additional function panels are shown on the next page.
2.5U-PANEL-RACK16
Accepts up to 16 of our plugin DAQ and PAD series signal conditioning modules.
(Compatible also with all HSI modules, except that it limits their bandwidth to 300 kHz)
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
1
2.5U-PANEL-RACK16-HSI
Accepts up to 16 of our plugin HSI series signal conditioning modules. Also compatible with most DAQ and PAD series modules (not compatible with DAQP-CHARGE-A and
DAQP-FREQ-A and other very old DAQ modules).
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
2
1
3
5
We can install zero, one, or two of the above PANELS for DAQ/PAD/HSI modules onto the rear panel of the DEWE-3050. See the yellow outlines of where they will be located.
When one 2.0U-PANEL-RACk-16 / HSI is installed, there are still four positions for
MDAQ conditioners (up to 64 channels). See blue outlines.
When two 2.0U-PANEL-RACk16 / HSI are installed, there are no spaces available left for MDAQ conditioners.
34
Dewetron ProDUCt SeLeCtIon GUIDe
2.0U-PANEL-MDAQ
Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type, for
16 total differential input channels.
If no RACk16’s are installed up to 6 of these MDAQ PANELS can be installed, for a total of 96 channels. If one RACk16 is installed, up to 4 of these MDAQ PANELS can be installed, for up to 64 channels.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
1.5U-PANEL-MDAQ-BNC
Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only, for 16 total differential input channels.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
2
4
6
Note: BNC only panels are oly 1.5U high, leaving a 0.5U space underneath for additioanl function panels. See the next pages for the complete list.
Several additional 1U and 2U PANELS are also available for other functions. See the next pages for a complete list.
Unfilled space on the rear panel will be filled with modular blank panels, leaving your
DEWE-3050 ready for future upgrades.
Dewetron ProDUCt SeLeCtIon GUIDe
35
DEWE-3050 more function panels
Here are the additional FUNCTION PANELS that are available for your DEWE-3050:
0.5U function panels
0.5U-DA2-BNC
0.5U panel with BNC connectors, supporting two analog outputs.
0.5U-DA4-BNC
0.5U panel with BNC connectors, supporting four analog outputs.
0.5U-DA8-BNC
0.5U panel with BNC connectors, supporting eight analog outputs.
0.5U-AMFLEX-POWER-4
0.5U panel with BINDER 712 connectors, 9VDC power supply for up to eight PNA-100 current sensors.
0.5U-AMFLEX-POWER-8
0.5U panel with BINDER 712 connectors, 9VDC power supply for up to eight PNA-100 current sensors.
0.5U-CLAMP-DC-POWER-4
0.5U panel with LEMO connectors, 15VDC power supply and digital status lines for up to four PNA-CLAMP-150-DC current sensors.
0.5U-CLAMP-DC-POWER-8
0.5U panel with LEMO connectors, 15VDC power supply and digital status lines for up to eight PNA-CLAMP-150-DC current sensors.
1.0U and 1.5U function panels
1U-DA8-BNC
1U panel with BNC connectors, supporting eight analog outputs.
1U-DA16-BNC
1U panel with BNC connectors, supporting sixteen analog outputs.
1.5U-ORION-DIO-PANEL-1
1.5 U panel with 8 LEMO connectors EGG.1B.307 for up to
8 counters and one DSUB-37 connector for up to 16 digital inputs, incl. mating connectors (compatible with counter expansion options).
1.5U-TC-PANEL-32
1.5U panel prepared for up to 32 thermocouple inputs.
Please add up to four MPAD-TH8-k and/or MPAD-TH8-T options. Each MPAD provides 8 input channels.
36
Dewetron ProDUCt SeLeCtIon GUIDe
Factory installed upgrades available at the time of ordering:
UP-ORION-CAN2
Adds two high speed CAN BUS interfaces, the DB9 connectors, and the software option inside DS-7.
UP-ORION-CTR8
Upgrades the digital inputs to 8 TTL digital inputs protected up to 25 VDC, and 8 counter/encoder inputs with programmable threshold (0-40VDC) and -35 to 60V range, AC/DC coupling. Includes DB37 connector and mate.
UP-ORION-16-22
Upgrade the A/D card to 22-bit resolution with anti-aliasing filtering, with 100 kS/s/ch max sample rate.
UP-ORION-16-24
Upgrade the A/D card to 24-bit resolution with anti-aliasing filtering, with 200 kS/s/ch max sample rate.
UP-ORION-100-500
UP-ORION-100-1000
DN-ORION-AD16-1000-16
Upgrade the A/D card to 500 kS/s/ch max sample rate.
Upgrade the A/D card to 1000 kS/s/ch max sample rate.
Downgrade the A/D card to multiplexed 16-bit card with
1MS/s/ aggregate sample rate, 2 simple counters, and 8
TTL digital I/O lines.
ORION-SYNC
Installs a SyNC interface and in/out RJ45 connectors for multi-system synchronization
3210-DC-POWER
Upgrades the power system to run from a wider DC range:6 to 30 VDC max. (instead of 18-24 VDC max).
RAM-2048-3072
RAM-2048-4096
HDD-SDD-32
Upgrades the computer RAM from 2 GB to 3 GB
Upgrades the computer RAM from 2 GB to 4 GB
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 32 GB size
HDD-SDD-64
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 64 GB size
HDD-SDD-128
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 128 GB size
HDD-SDD-256
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 256 GB size
There are other options and upgrades available - please consult your DEWETRON representative for the latest information, and for pricing.
The right side panel door provides access to the batteries, which can be hot-swapped during operation. Compatible with SIdeHAND2 batteries (four are included).
Dewetron ProDUCt SeLeCtIon GUIDe
37
DEWE-3050 expansion guide
Expansion via analog cable
A very popular way of expanding the analog inputs is to install more ORION cards into the instrument and connect external signal conditioning amplifiers via analog cables. Each
DEWE-3050 instrument has two spare PCI slots which can be used to install additional ORION cards. Select a suitable external DEWE-30 or
DEWE-31 series signal conditioning rack, the required amplifiers and directly connect the analog outputs to the ORION cards by analog signal cables.
DEWE-31-12
DEWE-ORION card in main system
A
NA
LOG
SIGNALS
P
OW
ER S
UPPLY AC (optional DC) power supply
Expansion chassis
Amplifier slots
MDAQ channels
A/D converter
Power supply (standard)
Dimensions (WxDxH)
Weight
8
--
DEWE-30-8 DEWE-30-16
16
--
DEWE-30-32
32
--
DEWE-31-16
--
8 or 16
(Connects to the A/D card in the main system - there is no A/D converter inside any DEWE-30 or DEWE-31 chassis)
120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
4 kg (9 lbs)
120/230 VAC 50/60 Hz
435 x 223 x 245 mm
16.1 x 13/4 x 7.9 in
7 kg (15 lbs)
DC from the mainframe or via
AC/DC adapter
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in
1.6 kg (3.5 lbs)
DEWE-31-32
--
8, 16, 24 or 32
120/230 VAC 50/60 Hz
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
4 kg (9 lbs)
DEWE-3200
DEWE-52-PCI-3216
PCI HOST
SyNC
AC (optional DC) power supply
Expansion via PCI bridge
The PCI expansion is an alternative especially if high channel count is needed. When using an expansion only one PCI slot is occupied in the
DEWE-3050 instrument by a PCI-HOST-CARD. The DEWE-50, DEWE-51 and DEWE-52 ADC racks can be connected by a 1m PCI cable. The
ORION cards are installed inside the DEWE-5x unit and you simply have to select the suitable signal amplifiers for your needs.
Important notice: The DEWE-3050 and the DEWE-5x must be equipped with ORION-SYNC option.
User tip: with an additional ECARD-34 or 54 the DEWE-5x also can be used as an independent system in combination with a laptop computer.
Expansion chassis
Amplifier slots
MDAQ channels
ORION card slots
Power supply (standard)
Dimensions (WxDxH)
Weight
38
DEWE-50-PCI-32
32
--
3
120/230 VAC 50/60 Hz
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
10 kg (22 lbs)
DEWE-50-PCI-64
64
--
7
120/230 VAC 50/60 Hz
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in.
15 kg (33 lbs)
Dewetron ProDUCt SeLeCtIon GUIDe
DEWE-51-PCI-32
--
Up to 64
7
120/230 VAC 50/60 Hz
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
6 kg (13 lbs)
DEWE-51-PCI-128
--
Up to 128
13
120/230 VAC 50/60 Hz
408 x 287 x 267 mm
16.1 x 11.3 x 10.5 in
9 kg (20 lbs)
DEWE-52-PCI-3216
16
Up to 32
7
120/230 VAC 50/60 Hz
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
9 kg (20 lbs)
Expansion via Ethernet
The NET expansion is a fantastic way to combine two or more DEWE instruments to one multichannel system. Each instrument must have installed hardware option ORION-
SYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First is a simple cable connection for distances up to 200 m, second one is GPS- or IRIG-CLOCK which is useful for long distances when a cable connection is not possible. DS-OPT-
NET software offers full remote setup, online data transfer up to the limit of the network connection and offline data transfer between the instruments.
User tip: The NET expansion also distributes the data processing load among multiple computers, each of which can store data at full speed.
DEWE-3050
DEWE-3050
SyNC
ETHERNET
GPS-CLOCk
SyNC
ETHERN
ET
0.000 ms
DEWE-3050
DEWE-3050
GPS-CLOCk
SyNC
Specifications
Specification
Slots for DAQ/PAD/HSI modules
MDAQ-SUB positions
DEWE-3050
32 with two 2.0U-PANEL-RACk-16‘s or -HSI‘s
12, via six 2.0U-PANEL-MDAQ‘s (or 1.5U-PANEL-MDAQ-BNC‘s (96 total analog channels)
Main system
Total PCI slots
Hard disk
5 x full length PCI slots
2 x removable HDDs (500 GB for data, 100 GB for the OS)
Data throughput to disk
Power supply
Display
Processor
RAM
Ethernet
USB
RS232 serial interface
Optical drive
Operating system
Dimensions (W x D x H)
Weight
50 MB/s typical; faster rates available with the additional of an internal
RAID controller and/or additional drives
Hot-swappable batteries, operates from 18~24 VDC. Includes DPS-2410 external AC/DC power adapter for recharging the batteries and operating the system from AC mains.
17” SXGA display, 1280 x 1024 px, with CAPACITIVE touchscreen
Intel i7 CPU, on a standard industrial grade ATX mainboard
4 GB
2 x Gb ethernet interfaces
Four x USB 2.0 interfaces
One serial interface (DB9 connector)
External only due to shock & vibe compliance (option OPT-CDR)
Microsoft Windows7 32-bit included
425 x 340 x 191 mm (16.7 x 13.4 x 7.5 in.)
10 kg typical (22 lbs) without batteries
Environmental specifications
Operating temperature
Humdity
Vibration
0 to 50°C (-20°C when pre-warmed )
10 to 80% non-condensing, 5 to 95% relative humidity
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock MIL-STD-810F, EN 60068-2-27
Data acquisition specifications
Standard A/D card specifications: 100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100)
Upgrades to faster cards, and higher resolution cards available
Available A/D card upgrades:
Data acquisition software:
Software upgrades available:
Analog inputs:
Signal conditioning available:
EPAD interface:
Computer upgrades
RAM upgrades:
Hard disk drive upgrade:
Filtering upgrades:
UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing
UP-ORION-16-22: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing
UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch
UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch
DS-7-SE is included as standard
To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS
16, according to the installed DAQ, PAD, HSI, or MDAQ signal conditioners
Isolated/differential conditioners for low voltage, high voltage, strain, bridge, pressure, thermocouples, RTDs, IEPE, charge
Standard LEMO 4-pin connector, right side panel
N/A
Add an internal drive, or increase the size of the removable drive, or convert one or both removable drives to solid state drives
DAQ/HSI modules have filters built-in
MDAQ-FILT options available for MDAQ systems
Popular interfaces
CAN BUS interfaces: UP-ORION-CAN2 adds 2 high-speed synchronous CAN BUS interfaces on
DB9 connectors, and DS-OPT-CAN software option
Time code interface:
VIDEO-FG-4
ARINC-429
Adds an internal IRIG or GPS time code interface (does not require a PCI slot)
Adds a four channel VIDEO INPUT PCI card to the system. Four BNCs for analog NTSC video input on the right side panel, allowing four video streams to be recorded in sync with the data
Several different interface cards are available with various numbers of
ARINC 429 transmit and receive channels
MIL-STD-1553 Several different interface cards are available with various numbers of MIL-
STD-1553 transmit and receive channels
Rear panel conditioner positions:
Plug-in module positions: Up to 32 modules via 2.0U-PANEL-RACk16 or -HSI options
Differential conditioner positions: Up to 12 MDAQ-SUB conditioners (96 channels) via 2.0U-PANEL-MDAQ or
1.5U-PANEL-MDAQ-BNC options
PANEL spaces Differential conditioner positions:
External channel expansion
Low-speed channel expansion: Up to 16 EPAD2 modules can be connected to the EPAD connector, adding up to 128 channels of low-speed thermocouple, voltage, RTD, and current inputs, in blocks of eight channels
Expansion via analog cable:
Expansion via PCI bridge:
Expansion via ethernet:
Up to 96 total dynamic analog input channels (with three 32-channel A/D cards installed inside the DEWE-3210, and external DEWE-30/31 chassis connected.
Up to 256 total dynamic analog input channels (with PCI bridge card installed inside the DEWE-3210, and external DEWE-50/51 chassis connected.
Up to 2000 total dynamic analog input channels (with SyNC option for local connections, or IRIG/GPS sync for remote connections, and multiple remote DEWE systems synchronized via DS-OPT-NET software option.
Dewetron ProDUCt SeLeCtIon GUIDe
39
DEWE-3050 ordering guide
Please use the table below to configure your DEWE-3050 system. From this ordering guide, your DEWETRON representative can create a detailed price quote for you.
First, please choose your basic model: deWe-3050
Benchtop / portable battery-powered data acquisition system
16-bit resolution, simultaneous sampling, 100 kS/s per channel
8 synchronous TTL digital I/Os
2 synchronous TTL counter / encoder or 8 TTL digital inputs
6.0U panel space available for signal conditioners
Choose from plugin DAQ / PAD / HSI series conditioning modules or
MDAQ differential signal conditioning inputs (16 channels) or a combination
2 free PCI slots (3 full length slots are inside, one is used by the A/D card) EPAD2 connector for optional EPAD2 modules. DS-7-SE software is included
NeXt, please choose the siGNal coNditioNiNG paNel(s) that you Need (Factory iNstalled, see previous paGes For possibilities):
2.5u-paNel-racK16
2.5U Card cage for up to 16 DAQ / HSI / PAD module slots, 300 kHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
2.5u-paNel-racK16-hsi
2.0u-paNel-mdaQ-dsub
2.5U Card cage for up to 16 HSI / DAQ / PAD module slots, 2 MHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
Not compatible with the DAQP-CHARGE-A, DAQP-FREQ-A, and certain older DAQ modules
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where either or both of have 9-pin DSUB connectors.
Please order your choice of MDAQ-SUB-XX-D conditioners separately (2 required).
1.5u-paNel-mdaQ-bNc
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where both have BNC connectors. Please order your choice of MDAQ-SUB-XX-BNC conditioners separately (2 required).
additioNal available coNNector paNels
0.5u-orioN-cNt2-lemo
1.5u-orioN-dio-paNel-1
0.5 U panel with 2 LEMO connectors EGG.1B.307 connected to the 2 counters of an ORION base card, incl. mating connectors
1.5 U panel with 8 LEMO connectors EGG.1B.307 for up to 8 counters and 1 DSUB-37 connector for up to 16 digital inputs, incl. mating connectors, requires UP-ORION-CNT
0.5u-ampFleX-poWer-8
0.5 U panel with 8 Binder 712 connectors, 9 V Power supply for PNA-A100 current transducers
0.5u-clamp-dc-poWer-4 0.5 U panel with 4 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
0.5u-clamp-dc-poWer-8 0.5 U panel with 8 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
1.5u-tc-paNel-32
1.5U panel prepared for up to 32 thermocouple inputs; please add one to four MPAD-TH8-x options
mpad-th8-K mpad-th8-t
0.5u-da2-bNc
0.5u-da4-bNc
0.5u-da8-bNc
Adds 8 internal thermocouple inputs type K to the 1.5U-TC-PANEL-32, sampling rate 12 Hz
Adds 8 internal thermocouple inputs type T to the 1.5U-TC-PANEL-32, sampling rate 12 Hz
0.5 U panel with 2 BNC connectors connected to the 2 analog outputs of an AD16-1000-16-OUT2 card
0.5 U panel with 4 BNC connectors connected to the 4 analog outputs of a DA4-1000-16 card
0.5 U panel with 4 BNC connectors connected to the 8 analog outputs of a DA8-1000-16 card
please choose aNy a/d card upGrades that you reQuire (Factory iNstalled oNly): up-orioN-16-22
Upgrade the standard 16-channel A/D card from 16-bit resolution to 22-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1622-100). The max. sample rate remains at 100 kS/s/ch.
up-orioN-16-24 up-orioN-100-500 up-orioN-100-1000 up-orioN-1616-3216 dN-orioN-ad16-1000-16 more a/d cards:
Upgrade the standard 16-channel A/D card from 16-bit resolution to 24-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1624-200). The max. sample rate increases to 204.8 kS/s/ch.
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 500 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-500).
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 1000 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-1000).
Upgrade the standard 16-channel A/D card from 16 to 32 simultaneously sampled channels (converts from ORION-1616-100 to
ORION-3216-100). The max. sample rate remains at 100 kS/s/ch.
Replaces the standard A/D card from ORION-1616-100 to AD16-1000-16, which provides:
Single ADC multiplexed 16-bit A/D card, 1000 kS/s aggregate max. sample rate (62.5 kS/s/ch max sample rate when all 16 analog channels are recording), 8 TTL digital I/O lines (compatible with DS-7 ALARMS), 2 basic counter inputs.
Note: this card is not compatible with any UP-ORION series options.
Note: if CAN BUS interfaces are desired with this A/D card, please order the PCI-CAN2 card and DS- OPT-CAN software option.
Because this system can support up to three A/D cards, please see the separate price list section if you wish to add more than the one A/D card which is included in the mainframe price. ORION and AD series A/D cards must be the same bit resolution and speed to be used at the same time.
40
Dewetron ProDUCt SeLeCtIon GUIDe
NeXt, please list the siGNal coNditioNers that you Would liKe to have:
There are too many possibilities to list them all here. Please see the separate signal conditioner pages, and select the models that you desire, and their quantities:
daQ modules
300 kHz bandwidth modules: DAQP-HV high voltage, DAQP-LV low voltage, DAQP-STG strain/universal
50 kHz bandwidth modules: DAQP-ACC-A accels (IEPE), DAQP-CHARGE-A accels (charge)
3 kHz bandwidth modules: DAQP-MULTI (bridge/universal, DAQP-THERM universal thermocouple
hsi modules
2 MHz bandwidth modules: HSI-HV high voltage, HSI-LV low voltage
1 MHz bandwidth modules: HSI-STG strain/universal
pad modules
PAD-TH8-P 8-ch thermocouple module, PAD-V8-P 8-ch voltage module
mdaQ-sub amps
300 kHz bandwidth modules: MDAQ-SUB-V200-BNC 8 channel voltage, MDAQ-SUB-ACC(-A) 8 channel accel (IEPE)
30 kHz bandwidth modules: MDAQ-SUB-STG 8 channel strain/universal, MDAQ-SUB-BRIDGE 8 channel bridge/universal
msi adapters
For -STG-D/BRIDGE-D amps: MSI-BR-V-200 voltage, MSI-BR-ACC accel (IEPE), MSI-BR-CHA accel (charge), MSI-BR-RTD temperature (RTD), MSI-BR-TH-J(-K, -T, -C) temperature (thermocouple)
NeXt, please choose aNy hardWare upGrades that you Would liKe (Factory iNstalled, diFFicult or impossible to add later): orioN-syNc hdd-sata-1tb system-ssd-64 hdd-600-ssd-32 hdd-600-ssd-64
Synchronization option for instruments with ORION cards, allows synchronization of PC based instruments or ADC Racks for PCI, all systems must have ORION-xx16 cards. Includes 2 m CAT-5E sync-cable, max. length of the sync-cable can be 50 m, this option is required for each unit which needs synchronization
Adds a 1 TB (1000 GB) standard S-ATA HDD inside the chassis
Additional internal 64 GB flash disk for Windows and DS7, the removable hard disk remains
Upgrade to 32 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
Upgrade to 64 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
hdd-600-ssd-128 ram-2048-3072 mob-disp-17
Upgrade to 128 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
Upgrade the standard 2 GB RAM to 3 GB RAM>
NeXt, please choose aNy soFtWare upGrades that you Would liKe (Factory iNstalled, but caN be added later): ds-up-se-proF
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 16 channels of A/D are installed)
ds-up-se-dsa
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 64 channels of A/D are installed)
NeXt, please choose aNy accessories that you Would liKe:
Mobile high brightness 17” display with capacitive touchscreen, 1280x1024 pixels, USB touchscreen interface + DVI + VGA interfaces
Wide range DC power input (12V/24V, up to 5A), INCLUDES: #1/4-20 cup mounting points on top and sides; standard VESA100 mounting positions on the rear panel; two USB 2.0 interfaces on the side; 1 m VGA cable with DVI adapter; 2.5 m USB cable, 1 m power cable, FGG.1B.302.CLA LEMO to banana plugs; AC/DC adapter for lab usage.
disp-17-opt hdd-rem-bacKup
Accessory set for MOB-DISP-17 for use inside vehicles, includes: two high-grade suction cups; 3 m VGA cable; 3 m USB cable; 1 meter power cable (LEMO to cigarette lighter plug)
Spare hard disk, installed inside removable drive carrier. If ordered with the system, we will clone the removable HDD onto this HDD, so that it can be used to restore the system in the event of HDD failure.
ctr-cbl-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m
NeXt, please choose aNy iNterFaces that you Would liKe to have iNstalled: ariNc or 1553 pcm interface
FG-video-4 time code
Please select from the separate lists
Please select from the separate lists
4 input NTSC video frame grabber. Requires one PCI or PCIe slot within the system.
Please select from the separate lists
other optioNs aNd services available: cal-daQ/mdaQ-Nist
Calibration of any single DAQ / PAD/HSI conditioner, or any MDAQ-SUB series 8-channel signal conditioning module. Includes a
NIST traceable CAL report generated by our Fluke MET/CAL system. This calibration includes the MDAQ-BASE card which holds two
MDAQ-SUB cards. The A/D card and MDAQ modules are calibrated together under our procedure. Dewetron’s USA cal lab is ANSI/
NCSL Z540-1 compliant. This calibration is valid for one year.
WarraNty-eXt-12-24
WarraNty-eXt-12-36
Warranty extension, 6 % of total system price for the second year, hardware only. Must be ordered with the initial purchase order
Warranty extension, 14 % of total system price for a total of 3 years, hardware only. Must be ordered with the initial purchase order
Dewetron ProDUCt SeLeCtIon GUIDe
41
Dewe-3040-rM rear/side view, with modular rear panel
Dewe-3040 -rM with 19” wide display
DEWE-3040-RM series
www.dewamerica.com/Products/DEWE-3050-RM
OVERVIEw
The DEWE-3040-RM is our flagship RACK-
MOUNTING data acquisition instrument. It has a
16-channel A/D card installed already, with 100 kS/s/ ch simultaneous sampling and 16-bit resolution. Our
DS-7 software is also included.
Simply choose your plugin modules or factory installed
MDAQ signal conditioners (or a combination) in order to complete your system. You can also add more A/D cards and expand the system up to 96 channels.
The rear panel supports up to 16 DAQ/PAD/HSI plugin signal conditioners, or up to 96 channels of MDAQ conditioners ... or a combination 16 DAQ/PAD/HSI plus 64 MDAQ conditioners.
There are always eight digital I/O lines, plus two counter inputs compatible with tachometers and encoders are standard, of course. You can also add interfaces to record bus data from ARINC, 1553, PCM,
CAN...as well as VIDEO, and more.
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
16 channel, 100 kS/s/ch simultaneous sampling A/D card card inside
Expandable to 96 FAST internal channels!
DS-7-SE software included
Choose from DAQ, PAD, HSI, MDAQ and MPAD series signal conditioners in countless combinations
500 GB removable HDD on front-panel
Built-in 19” W-I-D-E display
19” display, 1280x1024 resolution keyboard and touchpad built-in keyboard slides out when needed
Ruggedized construction, MIL-STD, EN-
STD, and more
Made in USA
Full year warranty
42
Dewetron ProDUCt SeLeCtIon GUIDe
◙
◙
◙
◙
◙
◙
◙
aPPliCations
◙ Flight test ground station recording
◙ Test cell data acquisition
Energy test (with DAQ/HSI modules)
Vehicle test cells
Aircraft test cells
Wind tunnel test cells
Production test cells
Voltage/current/power monitoring
Every kind of mechanical and structural test
flexiBle rear Panel
The DEWE-3040-RM can be configured with 16 slots for any of our plug-in modules in the DAQ,
PAD, and HSI series, plus up to 64 channels of
MDAQ conditioners.
Or, if you only need MDAQs, we can configure the rear panel with up to 96 channels (12 x 8 channel
MDAQ-SUB conditioners). There are six 2.0U
PANEL positions, so you can also add MPAD blocks of 32 thermocouples, and a wide variety of other interfaces and connectors to the rear panel.
maDe for the 19” raCk CaBinet
There is no “rack kit” needed, because the DEWE-
3040-RM has rack mounting ears already built in as an integral part of the chassis. Slides are also included, and the tapped mounting holes are already prepared for you.
There are no commonly accessed connections on either side panel - everything is located on the front or the back for maximum rack-mounting convenience.
Dewetron ProDUCt SeLeCtIon GUIDe
43
DEWE-3040-RM configuration guide
To complete your DEWE-3040-RM, you just need to choose the signal conditioners that you want. There are two basic choices: plug-in DAQ/PAD/HSI modules, or factory installed MDAQ conditioners. Choose plug-in modules when you want the ultimate in modularity and/or SIGNAL ISOLATION. Choose MDAQ conditioners when differential inputs are sufficient, and/or you want as many channels as possible on the mainframe.
The DEWE-3040-RM can accept a huge number and variety of signal conditioners on its rear panel - choose the ones that you want and we’ll do the rest.
Please refer to the graphic here to see what can be installed on the rear panel.
Additional function panels are shown on the next page.
2.5U-PANEL-RACK16
Accepts up to 16 of our plugin DAQ and PAD series signal conditioning modules.
(Compatible also with all HSI modules, except that it limits their bandwidth to 300 kHz)
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
1
1
1
3
2.5U-PANEL-RACK16-HSI
Accepts up to 16 of our plugin HSI series signal conditioning modules. Also compatible with most DAQ and PAD series modules (not compatible with DAQP-CHARGE-A and
DAQP-FREQ-A and other very old DAQ modules).
See the CONDITIONERS section for a complete list of all DAQ/PAD modules.
5
We can install either one (or neither) of the above PANELS for DAQ/PAD/HSI modules onto the rear panel of the DEWE-3040-RM. See the yellow outline of where it will be located.
When one 2.0U-PANEL-RACk-16 / HSI is installed, there are still four positions for
MDAQ conditioners (up to 64 channels). See blue outlines.
When a 2.0U-PANEL-RACk16 / HSI is NOT installed, there are SIX 2.0U spaces available left for MDAQ and other PANELS!
44
Dewetron ProDUCt SeLeCtIon GUIDe
2.0U-PANEL-MDAQ
Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type, for
16 total differential input channels.
If no RACk16’s are installed up to 6 of these MDAQ PANELS can be installed, for a total of 96 channels. If one RACk16 is installed, up to 4 of these MDAQ PANELS can be installed, for up to 64 channels.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
2
4
6
1.5U-PANEL-MDAQ-BNC
Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only, for 16 total differential input channels.
See the CONDITIONERS section for a complete list of all MDAQ conditioners.
Note: BNC only panels are oly 1.5U high, leaving a 0.5U space underneath for additioanl function panels. See the next pages for the complete list.
Several additional 1U and 2U PANELS are also available for other functions. See the next pages for a complete list.
Unfilled space on the rear panel will be filled with modular blank panels, leaving your
DEWE-3040-RM ready for future upgrades.
Dewetron ProDUCt SeLeCtIon GUIDe
45
DEWE-3040-RM function panels
Here are the additional FUNCTION PANELS that are available for your DEWE-3040-RM:
0.5U function panels
0.5U-DA2-BNC
0.5U panel with BNC connectors, supporting two analog outputs.
0.5U-DA4-BNC
0.5U panel with BNC connectors, supporting four analog outputs.
0.5U-DA8-BNC
0.5U panel with BNC connectors, supporting eight analog outputs.
0.5U-AMFLEX-POWER-4
0.5U panel with BINDER 712 connectors, 9VDC power supply for up to eight PNA-100 current sensors.
0.5U-AMFLEX-POWER-8
0.5U panel with BINDER 712 connectors, 9VDC power supply for up to eight PNA-100 current sensors.
0.5U-CLAMP-DC-POWER-4
0.5U panel with LEMO connectors, 15VDC power supply and digital status lines for up to four PNA-CLAMP-150-DC current sensors.
0.5U-CLAMP-DC-POWER-8
0.5U panel with LEMO connectors, 15VDC power supply and digital status lines for up to eight PNA-CLAMP-150-DC current sensors.
1.0U and 1.5U function panels
1U-DA8-BNC
1U panel with BNC connectors, supporting eight analog outputs.
1U-DA16-BNC
1U panel with BNC connectors, supporting sixteen analog outputs.
1.5U-ORION-DIO-PANEL-1
1.5 U panel with 8 LEMO connectors EGG.1B.307 for up to
8 counters and one DSUB-37 connector for up to 16 digital inputs, incl. mating connectors (compatible with counter expansion options).
1.5U-TC-PANEL-32
1.5U panel prepared for up to 32 thermocouple inputs.
Please add up to four MPAD-TH8-k and/or MPAD-TH8-T options. Each MPAD provides 8 input channels.
46
Dewetron ProDUCt SeLeCtIon GUIDe
FACTORY INSTALLED upgrades available at the time of ordering:
UP-ORION-CAN2
Adds two high speed CAN BUS interfaces, the DB9 connectors, and the software option inside DS-7.
UP-ORION-CTR8
Upgrades the digital inputs to 8 TTL digital inputs protected up to 25 VDC, and 8 counter/encoder inputs with programmable threshold (0-40VDC) and -35 to 60V range, AC/DC coupling. Includes DB37 connector and mate.
UP-ORION-16-22
Upgrade the A/D card to 22-bit resolution with anti-aliasing filtering, with 100 kS/s/ch max sample rate.
UP-ORION-16-24
Upgrade the A/D card to 24-bit resolution with anti-aliasing filtering, with 200 kS/s/ch max sample rate.
UP-ORION-100-500
UP-ORION-100-1000
DN-ORION-AD16-1000-16
Upgrade the A/D card to 500 kS/s/ch max sample rate.
Upgrade the A/D card to 1000 kS/s/ch max sample rate.
Downgrade the A/D card to multiplexed 16-bit card with
1MS/s/ aggregate sample rate, 2 simple counters, and 8
TTL digital I/O lines.
ORION-SYNC
Installs a SyNC interface and in/out RJ45 connectors for multi-system synchronization
3210-DC-POWER
Upgrades the power system to run from a wider DC range:6 to 30 VDC max. (instead of 18-24 VDC max).
RAM-2048-3072
RAM-2048-4096
HDD-SDD-32
Upgrades the computer RAM from 2 GB to 3 GB
Upgrades the computer RAM from 2 GB to 4 GB
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 32 GB size
HDD-SDD-64
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 64 GB size
HDD-SDD-128
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 128 GB size
HDD-SDD-256
Replaces the standard removable HDD with a SOLID
STATE removable HDD, 256 GB size
There are other options and upgrades available - please consult your DEWETRON representative for the latest information, and for pricing.
Dewetron ProDUCt SeLeCtIon GUIDe
47
DEWE-3040-RM expansion guide
Expansion via analog cable
A very popular way of expanding the analog inputs is to install more ORION cards into the instrument and connect external signal conditioning amplifiers via analog cables. Each
DEWE-3040-RM instrument has two spare PCI slots which can be used to install additional
ORION cards. Select a suitable external DEWE-
30 or DEWE-31 series signal conditioning rack, the required amplifiers and directly connect the analog outputs to the ORION cards by analog signal cables.
DEWE-31-12
DEWE-ORION card in main system
A
NA
LOG
SIGNALS
P
OW
ER S
UPPLY AC (optional DC) power supply
Expansion chassis
Amplifier slots
MDAQ channels
A/D converter
Power supply (standard)
Dimensions (WxDxH)
Weight
8
--
DEWE-30-8 DEWE-30-16
16
--
DEWE-30-32
32
--
DEWE-31-16
--
8 or 16
(Connects to the A/D card in the main system - there is no A/D converter inside any DEWE-30 or DEWE-31 chassis)
120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz DC from the mainframe or via
AC/DC adapter
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
4 kg (9 lbs)
435 x 223 x 245 mm
16.1 x 13/4 x 7.9 in
7 kg (15 lbs)
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in
1.6 kg (3.5 lbs)
DEWE-31-32
--
8, 16, 24 or 32
120/230 VAC 50/60 Hz
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
4 kg (9 lbs)
DEWE-3200
DEWE-52-PCI-3216
PCI HOST
SyNC
AC (optional DC) power supply
Expansion via PCI bridge
The PCI expansion is an alternative especially if high channel count is needed. When using an expansion only one PCI slot is occupied in the DEWE-3040-RM instrument by a PCI-HOST-CARD. The DEWE-50,
DEWE-51 and DEWE-52 ADC racks can be connected by a 1m PCI cable. The ORION cards are installed inside the DEWE-5x unit and you simply have to select the suitable signal amplifiers for your needs.
Important notice: The DEWE-3040-RM and the DEWE-5x must be equipped with ORION-SYNC option.
User tip: with an additional ECARD-34 or 54 the DEWE-5x also can be used as an independent system in combination with a laptop computer.
Expansion chassis
Amplifier slots
MDAQ channels
ORION card slots
Power supply (standard)
Dimensions (WxDxH)
Weight
48
DEWE-50-PCI-32
32
--
3
120/230 VAC 50/60 Hz
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
10 kg (22 lbs)
DEWE-50-PCI-64
64
--
7
120/230 VAC 50/60 Hz
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in.
15 kg (33 lbs)
Dewetron ProDUCt SeLeCtIon GUIDe
--
DEWE-51-PCI-32
Up to 64
7
120/230 VAC 50/60 Hz
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
6 kg (13 lbs)
DEWE-51-PCI-128
--
Up to 128
13
120/230 VAC 50/60 Hz
408 x 287 x 267 mm
16.1 x 11.3 x 10.5 in
9 kg (20 lbs)
DEWE-52-PCI-3216
16
Up to 32
7
120/230 VAC 50/60 Hz
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
9 kg (20 lbs)
Expansion via Ethernet
The NET expansion is a fantastic way to combine two or more DEWE instruments to one multichannel system. Each instrument must have installed hardware option ORION-
SYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First is a simple cable connection for distances up to 200 m, second one is GPS- or IRIG-CLOCK which is useful for long distances when a cable connection is not possible. DS-OPT-
NET software offers full remote setup, online data transfer up to the limit of the network connection and offline data transfer between the instruments.
User tip: The NET expansion also distributes the data processing load among multiple computers, each of which can store data at full speed.
DEWE-3040-RM
DEWE-3040-RM
SyNC
ETHERNET
GPS-CLOCk
SyNC
ETHERN
ET
DEWE-3040-RM
0.000 ms
DEWE-3040-RM
GPS-CLOCk
SyNC
Specifications
Specification
Slots for DAQ/PAD/HSI modules
MDAQ-SUB positions
DEWE-3040-RM
16 with 2.0U-PANEL-RACk-16‘s or -HSI‘s
12, via six 2.0U-PANEL-MDAQ‘s (or 1.5U-PANEL-MDAQ-BNC‘s), for 96 total analog input channels
Main system
Total PCI slots
Hard disk
Two full length PCI and two full length PCIe slots
500 GB standard removable drive (optional solid state drive)
Data throughput to disk
Power supply
Display
Processor
RAM
Ethernet
USB
RS232 serial interface
Optical drive
Operating system
Dimensions (W x D x H)
Weight
50 MB/s typical; faster rates available with the additional of an internal
RAID controller and/or additional drives
120/240 VAC 50/60 Hz AC mains, including IEC power cable.
19” WXGA display, 1400x900 px, with optional touchscreen
Intel Core2Duo 2.0 GHz CPU, on a ATX mainboard
2 GB (expandable to 4 GB)
2 x Gb ethernet interfaces
Four x USB 2.0 interfaces
One serial interface (DB9 connector)
DVD+-CD-RW drive built-in. CD burning capability included
Microsoft Windows7 32-bit included
425 x 340 x 191 mm (16.7 x 13.4 x 7.5 in.)
10 kg typical (22 lbs)
Environmental specifications
Operating temperature
Humdity
Vibration
0 to 50°C (-20°C when pre-warmed)
10 to 80% non-condensing, 5 to 95% relative humidity
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock MIL-STD-810F, EN 60068-2-27
Data acquisition specifications
Standard A/D card specifications: 100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100)
Upgrades to faster cards, and higher resolution cards available
Available A/D card upgrades:
Data acquisition software:
Software upgrades available:
Analog inputs:
Signal conditioning available:
EPAD interface:
Computer upgrades
RAM upgrades:
Hard disk drive upgrade:
Filtering upgrades:
UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing
UP-ORION-16-22: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing
UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch
UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch
DS-7-SE is included as standard
To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS
16, according to the installed DAQ, PAD, HSI, or MDAQ signal conditioners
Isolated/differential conditioners for low voltage, high voltage, strain, bridge, pressure, thermocouples, RTDs, IEPE, charge
Standard LEMO 4-pin connector, right side panel
Increase from 2 to 3 GB or 4 GB
Add an internal drive, or increase the size of the removable drive, or convert the removable drive to a solid state drive
DAQ/HSI modules have filters built-in
MDAQ-FILT options available for MDAQ systems
Popular interfaces
CAN BUS interfaces: UP-ORION-CAN2 adds 2 high-speed synchronous CAN BUS interfaces on
DB9 connectors, and DS-OPT-CAN software option
Time code interface:
VIDEO-FG-4
ARINC-429
Adds an internal IRIG or GPS time code interface (does not require a PCI slot)
Adds a four channel VIDEO INPUT PCI card to the system. Four BNCs for analog NTSC video input on the right side panel, allowing four video streams to be recorded in sync with the data
Several different interface cards are available with various numbers of
ARINC 429 transmit and receive channels
MIL-STD-1553 Several different interface cards are available with various numbers of MIL-
STD-1553 transmit and receive channels
Rear panel conditioner positions:
Plug-in module positions: Up to 16 modules via 2.0U-PANEL-RACk16 or -HSI options
Differential conditioner positions: Up to 12 MDAQ-SUB conditioners (96 channels) via 2.0U-PANEL-MDAQ or
1.5U-PANEL-MDAQ-BNC options
PANEL spaces Differential conditioner positions:
External channel expansion
Low-speed channel expansion: Up to 16 EPAD2 modules can be connected to the EPAD connector, adding up to 128 channels of low-speed thermocouple, voltage, RTD, and current inputs, in blocks of eight channels
Expansion via analog cable:
Expansion via PCI bridge:
Expansion via ethernet:
Up to 96 total dynamic analog input channels (with three 32-channel A/D cards installed inside the DEWE-3210, and external DEWE-30/31 chassis connected.
Up to 256 total dynamic analog input channels (with PCI bridge card installed inside the DEWE-3050-RM, and external DEWE-50/51 chassis connected.
Up to 2000 total dynamic analog input channels (with SyNC option for local connections, or IRIG/GPS sync for remote connections, and multiple remote DEWE systems synchronized via DS-OPT-NET software option.
Dewetron ProDUCt SeLeCtIon GUIDe
49
DEWE-3040-RM ordering guide
Please use the table below to configure your DEWE-3040-RM system. From this ordering guide, your DEWETRON representative can create a detailed price quote for you.
First, please choose your basic model: deWe-3040-rm
Rack-mounting AC-powered data acquisition system
16-bit resolution, simultaneous sampling, 100 kS/s per channel
8 synchronous TTL digital I/Os
2 synchronous TTL counter / encoder or 8 TTL digital inputs
6.0U panel space available for signal conditioners
Choose from plugin DAQ / PAD / HSI series conditioning modules or
MDAQ differential signal conditioning inputs (16 channels) or a combination
1 free PCI slot, 2 free PCIe slots (4 full length slots are inside, one is used by the A/D card) EPAD2 connector for optional EPAD2 modules. DS-7-SE software is included
NeXt, please choose the siGNal coNditioNiNG paNel(s) that you Need (Factory iNstalled, see previous paGes For possibilities):
2.5u-paNel-racK16
2.5U Card cage for up to 16 DAQ / HSI / PAD module slots, 300 kHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
2.5u-paNel-racK16-hsi
2.0u-paNel-mdaQ-dsub
2.5U Card cage for up to 16 HSI / DAQ / PAD module slots, 2 MHz max bandwidth
Please add your choice of up to 16 DAQ / PAD / HSI modules
Not compatible with the DAQP-CHARGE-A, DAQP-FREQ-A, and certain older DAQ modules
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where either or both of have 9-pin DSUB connectors.
Please order your choice of MDAQ-SUB-XX-D conditioners separately (2 required).
1.5u-paNel-mdaQ-bNc
Panel and MDAQ-BASE-5 module, for any two MDAQ-SUB signal conditioners, where both have BNC connectors. Please order your choice of MDAQ-SUB-XX-BNC conditioners separately (2 required).
additioNal available coNNector paNels
0.5u-orioN-cNt2-lemo
1.5u-orioN-dio-paNel-1
0.5 U panel with 2 LEMO connectors EGG.1B.307 connected to the 2 counters of an ORION base card, incl. mating connectors
1.5 U panel with 8 LEMO connectors EGG.1B.307 for up to 8 counters and 1 DSUB-37 connector for up to 16 digital inputs, incl. mating connectors, requires UP-ORION-CNT
0.5u-ampFleX-poWer-8
0.5 U panel with 8 Binder 712 connectors, 9 V Power supply for PNA-A100 current transducers
0.5u-clamp-dc-poWer-4 0.5 U panel with 4 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
0.5u-clamp-dc-poWer-8 0.5 U panel with 8 LEMO connectors, ±15 V Power supply and digital status lines for PNA-CLAMP-150-DC
1.5u-tc-paNel-32
1.5U panel prepared for up to 32 thermocouple inputs; please add one to four MPAD-TH8-x options
mpad-th8-K mpad-th8-t
0.5u-da2-bNc
0.5u-da4-bNc
0.5u-da8-bNc
Adds 8 internal thermocouple inputs type K to the 1.5U-TC-PANEL-32, sampling rate 12 Hz
Adds 8 internal thermocouple inputs type T to the 1.5U-TC-PANEL-32, sampling rate 12 Hz
0.5 U panel with 2 BNC connectors connected to the 2 analog outputs of an AD16-1000-16-OUT2 card
0.5 U panel with 4 BNC connectors connected to the 4 analog outputs of a DA4-1000-16 card
0.5 U panel with 4 BNC connectors connected to the 8 analog outputs of a DA8-1000-16 card
please choose aNy a/d card upGrades that you reQuire (Factory iNstalled oNly): up-orioN-16-22
Upgrade the standard 16-channel A/D card from 16-bit resolution to 22-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1622-100). The max. sample rate remains at 100 kS/s/ch.
up-orioN-16-24 up-orioN-100-500 up-orioN-100-1000 up-orioN-1616-3216 dN-orioN-ad16-1000-16 more a/d cards:
Upgrade the standard 16-channel A/D card from 16-bit resolution to 24-bit resolution, and add anti-aliasing filters (converts from
ORION-1616-100 to ORION-1624-200). The max. sample rate increases to 204.8 kS/s/ch.
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 500 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-500).
Upgrade the standard 16-channel A/D card from 100 kS/s/ch max sample rate to 1000 kS/s/ch (converts from ORION-1616-100 to
ORION-1616-1000).
Upgrade the standard 16-channel A/D card from 16 to 32 simultaneously sampled channels (converts from ORION-1616-100 to
ORION-3216-100). The max. sample rate remains at 100 kS/s/ch.
Replaces the standard A/D card from ORION-1616-100 to AD16-1000-16, which provides:
Single ADC multiplexed 16-bit A/D card, 1000 kS/s aggregate max. sample rate (62.5 kS/s/ch max sample rate when all 16 analog channels are recording), 8 TTL digital I/O lines (compatible with DS-7 ALARMS), 2 basic counter inputs.
Note: this card is not compatible with any UP-ORION series options.
Note: if CAN BUS interfaces are desired with this A/D card, please order the PCI-CAN2 card and DS- OPT-CAN software option.
Because this system can support up to three A/D cards, please see the separate price list section if you wish to add more than the one A/D card which is included in the mainframe price. ORION and AD series A/D cards must be the same bit resolution and speed to be used at the same time.
50
Dewetron ProDUCt SeLeCtIon GUIDe
NeXt, please list the siGNal coNditioNers that you Would liKe to have:
There are too many possibilities to list them all here. Please see the separate signal conditioner pages, and select the models that you desire, and their quantities:
daQ modules
300 kHz bandwidth modules: DAQP-HV high voltage, DAQP-LV low voltage, DAQP-STG strain/universal
50 kHz bandwidth modules: DAQP-ACC-A accels (IEPE), DAQP-CHARGE-A accels (charge)
3 kHz bandwidth modules: DAQP-MULTI (bridge/universal, DAQP-THERM universal thermocouple
hsi modules
2 MHz bandwidth modules: HSI-HV high voltage, HSI-LV low voltage
1 MHz bandwidth modules: HSI-STG strain/universal
pad modules
PAD-TH8-P 8-ch thermocouple module, PAD-V8-P 8-ch voltage module
mdaQ-sub amps
300 kHz bandwidth modules: MDAQ-SUB-V200-BNC 8 channel voltage, MDAQ-SUB-ACC(-A) 8 channel accel (IEPE)
30 kHz bandwidth modules: MDAQ-SUB-STG 8 channel strain/universal, MDAQ-SUB-BRIDGE 8 channel bridge/universal
msi adapters
For -STG-D/BRIDGE-D amps: MSI-BR-V-200 voltage, MSI-BR-ACC accel (IEPE), MSI-BR-CHA accel (charge), MSI-BR-RTD temperature (RTD), MSI-BR-TH-J(-K, -T, -C) temperature (thermocouple)
NeXt, please choose aNy hardWare upGrades that you Would liKe (Factory iNstalled, diFFicult or impossible to add later): orioN-syNc hdd-sata-1tb system-ssd-64 hdd-600-ssd-32 hdd-600-ssd-64
Synchronization option for instruments with ORION cards, allows synchronization of PC based instruments or ADC Racks for PCI, all systems must have ORION-xx16 cards. Includes 2 m CAT-5E sync-cable, max. length of the sync-cable can be 50 m, this option is required for each unit which needs synchronization
Adds a 1 TB (1000 GB) standard S-ATA HDD inside the chassis
Additional internal 64 GB flash disk for Windows and DS7, the removable hard disk remains
Upgrade to 32 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
Upgrade to 64 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
hdd-600-ssd-128 ram-2048-3072 mob-disp-17
Upgrade to 128 GB flash disk (replaces the standard removable hard disk), no moving parts, extended temperature range, max. data throughput 20 MB/s
Upgrade the standard 2 GB RAM to 3 GB RAM>
NeXt, please choose aNy soFtWare upGrades that you Would liKe (Factory iNstalled, but caN be added later): ds-up-se-proF
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 16 channels of A/D are installed)
ds-up-se-dsa
Upgrade the standard DS-7-SE to DS-7-PROF (required when more than 64 channels of A/D are installed)
NeXt, please choose aNy accessories that you Would liKe:
Mobile high brightness 17” display with capacitive touchscreen, 1280x1024 pixels, USB touchscreen interface + DVI + VGA interfaces
Wide range DC power input (12V/24V, up to 5A), INCLUDES: #1/4-20 cup mounting points on top and sides; standard VESA100 mounting positions on the rear panel; two USB 2.0 interfaces on the side; 1 m VGA cable with DVI adapter; 2.5 m USB cable, 1 m power cable, FGG.1B.302.CLA LEMO to banana plugs; AC/DC adapter for lab usage.
disp-17-opt hdd-rem-bacKup
Accessory set for MOB-DISP-17 for use inside vehicles, includes: two high-grade suction cups; 3 m VGA cable; 3 m USB cable; 1 meter power cable (LEMO to cigarette lighter plug)
Spare hard disk, installed inside removable drive carrier. If ordered with the system, we will clone the removable HDD onto this HDD, so that it can be used to restore the system in the event of HDD failure.
ctr-cbl-05
Connection cable from counter input (FGG.1B.307) to open end, length 5 m
NeXt, please choose aNy iNterFaces that you Would liKe to have iNstalled: ariNc or 1553 pcm interface
FG-video-4 time code
Please select from the separate lists
Please select from the separate lists
4 input NTSC video frame grabber. Requires one PCI or PCIe slot within the system.
Please select from the separate lists
other optioNs aNd services available: cal-daQ/mdaQ-Nist
Calibration of any single DAQ / PAD/HSI conditioner, or any MDAQ-SUB series 8-channel signal conditioning module. Includes a
NIST traceable CAL report generated by our Fluke MET/CAL system. This calibration includes the MDAQ-BASE card which holds two
MDAQ-SUB cards. The A/D card and MDAQ modules are calibrated together under our procedure. Dewetron’s USA cal lab is ANSI/
NCSL Z540-1 compliant. This calibration is valid for one year.
WarraNty-eXt-12-24
WarraNty-eXt-12-36
Warranty extension, 6 % of total system price for the second year, hardware only. Must be ordered with the initial purchase order
Warranty extension, 14 % of total system price for a total of 3 years, hardware only. Must be ordered with the initial purchase order
Dewetron ProDUCt SeLeCtIon GUIDe
51
with the battery option, you can hot-swap the batteries when needed, keeping the system running indefinitely.
StG models are compatible with all
MSI-Br adapters, for maximum sensor compatibility
Dewe-214 with optional battery pack
(battery pack fastens to the bottom of the chassis)
DEWE-214 series
www.dewamerica.com/Products/DEWE-214
OVERVIEw
The DEWE-214 is our top of the line IN VEHICLE testing instrument. It’s small size and power system were specifically designed for mobile/vehicle applications. It’s quite at home in your car, truck, motorcycle, tank, military vehicle, train, boat, NASCAR vehicle...
The analog inputs are extremely flexible, and the A/D system behind them is top-notch: 24-bit resolution for the highest dynamic range, 200 kS/s/ch sampling
(max), simultaneous sampling, brick wall anti-aliasing filtering, and more.
The DEWE-214 also features two high speed CAN bus interfaces supporting CAN and J1939 protocols
(OBD II optional). There are also digital I/O lines and two counter inputs compatible with tachometers and encoders.
Choose which conditioner you want, then what speed of GPS sensor you would like: 1, 20, or 100 Hz.
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
8 high performance analog channels, 200 kS/s/ch simultaneous sampling
Anti-aliasing filtering standard
24-bit resolution for highest dynamic range
DS-7-SE software included
Available in two basic versions with three choice of GPS speeds
32 GB SLC solid state HDD (upgradable to
64, 128, 256 GB)
Optional MOBILE display keyboard and mouse included
Wide range DC power input 8~30 VDC
Battery power option - runs 2-3 hours without any external power connected
Batteries are hot-swappable - even during measurement
Ruggedized construction, MIL-STD, EN-
STD, and more
Full year warranty
52
Dewetron ProDUCt SeLeCtIon GUIDe
◙
◙
◙
◙
◙
◙
◙
◙
aPPliCations
◙ In-vehicle data acquisition
◙ Cars, trucks, motorcycles, trains
Race cards - NASCAR, Formula 1, Indy...
Aircraft, boats and ships
Military vehicle test
Field service and field test applications
Noise & vibration
All kinds of trouble-shooting
Every kind of mechanical and structural test
Every kind of MOBILE and VEHICLE test
maDe for the roaD
The DEWE-214 was designed specifically for invehicle testing. It starts with the wide-range DC power input (8~30VDC), and its amazingly small size and convenient form factor. Anchor points on the sides make it easy to strap down in a moving vehicle.
And the performance cuts no corners: 24-bit resolution for incredible dynamic range. The built-in
GPS, including 20 and 100 Hz receivers is ideal for dynamic testing, like brake and accel testing, ride and handling, driveability, and more.
Small but essential features like these tie-down “anchor” points, are standard in the Dewe-214.
moBile DisPlaY oPtion
The MOB-DISP-17 (option) is a great add-on for any portable DEWE system, especially for invehicle applications. This is a ruggedized display with a capacitive touchscreen (supports multi-touch software!) that’s brighter than ever.
And we built three USB 2.0 interfaces into it, so you can put the 214 in the trunk, and mount the MOB display up front. Use the USBs to connect memory sticks, or your keyboard, etc. Get the optional kit for the suction cups and longer cables for in-vehicle usage.
Dewetron ProDUCt SeLeCtIon GUIDe
53
DEWE-214 configuration
DEWE-214-STG model with 1, 20, or 100 Hz GPS
The DEWE-214-STG model features our most FLEXIBLE analog inputs, based on the MDAQ-STG conditioner. It can natively handle any kind of bridge or strain gage, with completion for half and quarter bridge sensors and various wiring methods, amp and sensor balance, and so much more. You can input ±10V directly. Using our MSI-BR series adapters you can also input IEPE accels and mics, charge sensors, thermocouples (J, K, T, C), RTD sensors (Pt100, 200, 500,
1000), voltages up to ±200V. We also offer ADAP series adapters for 4-20 mA sensors and simple BNC adapters.
Choose the GPS version you want, with 1, 20 or 100 Hz sensor.
The STG series is the more flexible of the two basic DEWE-214 models, and you can upgrade it to 16 channels!
Dewe-214-StG with optional channel expansion from 8 to 16 channels
(the standard model has the left-most 8 channels installed)
DEWE-214-ACC model with 1, 20, or 100 Hz GPS
Choose the DEWE-214-ACC model if you will be doing mostly IEPE inputs for noise, shock and vibration testing. There are eight 80 kHz bandwidth inputs with TEDS support, which provide the constant current excitation needed by IEPE accelerometers and microphones. You can input ±10V, ±2V, ±0.5 or ±0.1V directly. All of the analog inputs are on convenient BNC connectors. Maximum analog sample rate is 204.8 kS/s/ch. Anti-aliasing filtering is standard, of course.
Choose the GPS version you want, with 1, 20 or 100 Hz sensor.
54
Both DEWE-214 models include two synchronous SUPER counters, which are ideal for tachs, tape, and RPM sensors as well as encoders – and offer adjustable trigger levels, and input ranges beyond TTL. In addition, there are 8 TTL digital inputs (ideal for measuring simple switch closures and "discrete" signals) and 8 TTL digital outputs (great for alarm outputs, a standard software feature). All digital lines are available on the standard DB37 connector on the front panel.
LEMO connectors for the counters are available as an option (ORION-CNT2-LEMO).
Dewetron ProDUCt SeLeCtIon GUIDe
Expansion via Ethernet
The NET expansion is a fantastic way to combine two or more DEWE instruments to one multichannel system. Each instrument must have installed hardware option ORION-
SYNC and software option DS-OPT-NET.
Synchronization of all units is required too.
There are two ways of synchronization: First is a simple cable connection for distances up to 200 m, second one is GPS- or IRIG-CLOCK which is useful for long distances when a cable connection is not possible. DS-OPT-
NET software offers full remote setup, online data transfer up to the limit of the network connection and offline data transfer between the instruments.
User tip: The NET expansion also distributes the data processing load among multiple computers, each of which can store data at full speed.
DEWE-214
DEWE-214
SyNC
ETHERNET
GPS
(20Hz or 100Hz)
DEWE-214
DEWE-214
Specifications
Specification
Analog input channels
Expandable to 16 channels
Digital I/O lines (TTL)
Counter inputs
Counter specifications
Trigger input
Signal conditioning
Measuring modes:
Analog connector
Max sample rate
Analog bandwidth (-3 dB)
Bit resolution
Anti-aliasing filtering
MSI compatible
MSI adapters available
Slow channel expansion
CAN BUS interfaces
GPS sensor
GPS sensor
VIDEO input
Software included
DEWE-214 STG
8 (upgrade to 16 channels optional) yes (option 214-STG-08-16 adds 8 more STG channels, with the same specifications as the first 8 channels)
DEWE-214 ACC
8
N/A
8 in / 8 out (inputs are TTL/CMOS level with pull-up with 100 kΩ). Low range: -0.7 to 0.8V; High range: 2 to 5V
2 synchronous advanced counter / encoders
32-bit resolution, 80 MHz clock (40 MHz max input frequency) 5 MHz bandwidth, 1 MΩ input impedance (5pF), trigger level adjustable 0-40V, ±100V over voltage input protection, AC/DC input coupling (1 Hz HP filter with AC coupling), differential and symmetrical inputs, common voltage range: -35 to 50V
1 included, TTL Schmidt trigger, pull-up with 100 kΩ. Low range: -0.7 to 2V; High range: 3 to 5V
8 FLEXIBLE strain gage / voltage inputs, TEDS compatible 8 FLEXIBLE IEPE / voltage inputs, TEDS compatible
Full bridge, 1⁄2 bridge, 1⁄4 bridge 120 Ω, 1⁄4 bridge 350 Ω or ±10V voltage
Full bridge sensors 120 Ω to 10 kΩ
Internal completion for 1⁄2 bridge and 1⁄4 bridge sensors
Internal 50 kΩ and 100 kΩ shunt resistors
Voltage: ±0.125 V, 0.25 V, 0.5 V, 1 V, 1.25 V, 2.5 V, 5 V, 10 V
IEPE: 0.5, 1, 2, 4, 5, 10, 20, 40
Single ended or differential
DC or AC coupled (3 Hz standard, on request down to 0.1 Hz)
DB9
204.8 kS/s/ch
30 kHz
24-bit
Automatic
BNC
204.8 kS/s/ch
80 kHz
24-bit
Automatic yes
MSI-BR-ACC supports IEPE accels and mics; MSI-BR-CHA-50 supports dynamic charge sensors; MSI-BR-V200 supports voltages up to ±200V; MSI-BR-RTD supports Pt100/Pt200/Pt500/Pt1000 RTDs; MSI-BR-TH supports J, T, k, or C thermocouples
No
N/A
Via one or more EPAD2 and CPAD2 series isolated 8-channel signal conditioners. See EPAD2/CPAD2 section for the full range available
2 high-speed CAN BUS interfaces standard, on DB9 connectors. Supports CAN 2.0B and J1939 protocols (OBD-II support requires software option).
1 Hz standard (20 Hz and 100 Hz dynamic GPS sensor optional)
Speed, position, direction (20/100 Hz GPS options also output distance, acceleration, Z height and acceleration, UTC time reference)
1 Hz standard (20 Hz and 100 Hz dynamic GPS sensor optional)
Speed, position, direction (20/100 Hz GPS options also output distance, acceleration, Z height and acceleration, UTC time reference)
One USB camera can be used to add VIDEO to your data recordings. Compatible with all DirectX standard webcams.
DS-7-SE with CAN option. DS-7-SE is a complete data acquisition and analysis software package including unlimited setup file creation, on-line and off-line math channels
(including filtering, integration, and more), with scope, recorder, FFT, GPS map, VIDEO, analog and digital meter displays, and much more.
Main system
Hard disk
Power supply
Display
Processor
RAM
Interfaces built-in
Operating system
Dimensions (W x D x H)
Weight
Operating temperature
Humidity
Shock and Vibration
32 GB SLC solid state HDD, upgradable to 64 GB, 128 GB, or 256 GB. Data throughput to disk: typ. 40 MB/s continuous
8 ~ 30 VDC wide range DC power input, including external AC/DC adapter, and DC cable with cigarette lighter plug
Optional MOB-DISP-17 (1280x1024 px, high brightness, capacitive touchscreen (USB interface)
Intel® Core2Duo 2 GHz
2 GB (expandable to 3 GB)
2 x 1 Gb ethernet; WLAN (WIFI) including attachable antenna, 4 x USB 2.0, LEMO connector for Dewetron EPAD2 series modules
Microsoft Windows7 32-bit
317 x 252 x 92 mm (12.5 x 9.9 x 3.6 in.)
Typ. 5 kg (11 lb.)
0 to 50°C (-20°C when unit is pre-warmed and not powered off at temperatures below 0°C)
10 to 80% non-condensing; 5 to 95% relative humidity
Shock: EN 60068-2-27 ; Vibration: EN 60068-2-6, EN 60721-3-2 class 2M2, better than MIL-STD-810F (for shock and vibration)
Dewetron ProDUCt SeLeCtIon GUIDe
55
DEWE-214 interfaces
Two High-speed CAN BUS interfaces
Both DEWE-214 models feature two high-speed CAN
BUS interfaces compatible with the CAN 2.0B and
J1939 protocols. In the software you can import DBC setup files, or create your CAN setup manually if you like. There is a convenient "listen" function that scans the bus and identifies any messages that are coming across, and adds them to the list. It's easy to configure the channels that are contained within each message by bit range, name, scaling factor, and engineering units.
Everything gets saved into the setup file.
Configuring the channels within each message couldn’t be much easier.
when oBD II has been configured for a CAn interface, these standard channels are set up for you automatically. Just turn on the ones you want to record.
Use CAN for channel expansion, too
Dewetron CAN BUS interfaces can also be used for connecting CAN based sensors, including our own CPAD2 series 8 channel signal conditioners for thermocouples, voltages, currents, and RTDs. See the
CONDITIONERS section for a full listing of the CPAD2 modules that are available today. We even put power on two of the unused pins of the connector, so that we can directly power our CPAD2 modules. This conveniently eliminates the need to provide power to them separately.
But virtually any standard CAN output device can be used with our CAN interfacess, including non-Dewetron brand sensors and signal conditioners.
CAn channels are just like any others in your Dewetron system. You can display them, record them, use them in MAtH, trigger from them... no restrictions.
OBD II interface capabilities
If you want to read the OBD II messages, there is a software option for that. Simply configure either or both
CAN ports for OBD II, and the software will do the rest.
The software even includes an automatic listing of the basic codes, already set up for you.
56
Dewetron ProDUCt SeLeCtIon GUIDe
Typical Display:
where other systems show you some squiggly lines and maybe some numbers, that’s where we start.
You can show and record VIDeo (see below for details).
You can show and record CAn BUS data (see previous page for details).
You can show and record GPS data, both digitally as well as in a graphical GPS track. Bring in one or more satellite or map images and position them behind the track (this is easy to do).
You can show and record additional data from our ePAD2 and CPAD2 conditioners, as well as third-party
CAn based sensors.
You can show and record SerIAL and etHernet data from a wide variety of third party devices (just add a software plugin).
then create as many screens as you like in our software, and set them up just the way that you like.
that’s data acquisition like no one ever did it before.
that’s Dewetron.
WEB CAM / Gig-E CAM connection
Dewetron famously invented the use of common web cameras with data acquisition systems nearly 10 years ago. You can connect nearly every standard DirectX video camera in the world (one maximum) to your
DEWE-214 and start recording video in sync with your other data right away.
Or, for better performance, choose our DEWE-CAM-
GIGE-50 camera, and ethernet GIG-E camera!
VIDEO adds incredible context to your data acquisition.
AboveL Dewe-CAM-GIGe-50 Above: typical weB cam
Inertial sensors for dynamic testing
We offer two inertial sensors for a wide variety of vehicle test applications. There is a relativelyy inexpensive
XSENS MTi-G sensor that you can hold in your hand, for basic applications.
But for high-end applications such as CAPS, driveability, brake testing, etc. we offer the ADMA system from
GeneSys, completely integrated with your DEWE system.
See the SENSORS section for further details about both inertial sensors.
Dewetron ProDUCt SeLeCtIon GUIDe
57
DAQ and HSI series modules
Single channel, isolated
User exchangable
MDAQ series modules
Multi-channel, non-isolated
Factory installed
Signal Conditioners
http://www.dewamerica.com/Products/Conditioners
OVERVIEw
Dewetron offers a wide variety of signal conditioners for analog sensors, signals, and transducers. We have several series in order to better address the requirements of many applications, from power to electrical testing, and on to dynamic signal analysis.
Here is a brief overview of each type and how it is best applied:
DAQ Modules - AC/DC signals, single channel, user exchangable
at any time, HIGH ISOLATION, high bandwidth (most models)
HSI Modules - identical form factor to DAQ series modules,
except providing MHz level bandwidth, for high speed applications
MDAQ Modules - AC/DC signals, multi-channel, non-isolated,
high bandwidth, DENSE/LOW COST/CHANNEL
PAD Modules - DC signals (DCV, temperature), multi-channel,
isolated, low bandwidth, LOW COST/CHANNEL
EPAD2 Modules - external version of PAD modules
CPAD2 Modules - like EPAD except CAN BUS output
◙
◙
◙
◙
◙
◙
◙
◙
DAQ, PAD, EPAD2, and CPAD2 modules are user-exchangeable, even with the power on
DAQ/MDAQ modules output conditioned +/-
5V to Dewetron A/D cards for digitization
PAD/EPAD2/CPAD2 modules output digitized signals via serial/USB/CAN bus into the Dewetron computer
All Dewetron platforms support multiple module types in each chassis!
Some platforms support ALL module types!
Industrial grade constuction
CE Mark, ISO9001
Full year warranty
58
Dewetron ProDUCt SeLeCtIon GUIDe
PAD series modules
Multi-channel, isolated, slow signals
Plug into Dewetron systems
HSI series modules
Single channel, isolated, FASt signals (1 MHz)
Plug into Dewetron systems
Identical form factor to DAQ series modules.
T h e R i g h t To o l . . .
...for the right job. DAQ, HSI and MDAQ modules are made for AC/dynamic signals (of course they handle DC as well). With high dynamic performance and superb accuracy specifications, there are a wide variety of modules for every sensor. New is our
DAQP-STG UNIVERSAL SIGNAL CONDITIONER, which can do just about everything either directly using our MSI multi-sensor interfaces: strain, pressure, mV, 200 V, RTD, IEPE, charge sensors, and more. There is a similar MDAQ version of this module, too.
HSI modules are a whole new series with 1~2 MHz bandwidth, with the same form factor as DAQ and
PAD series modules. The first three HSI modules are the STG (universal), the HV (high voltage) and
LV (low voltage). These are an amazing combination of performance, size, price, isolation... only from
Dewetron.
PAD series plug into the same slots as DAQ modules, but are made for slow signals, usually temperature.
There are also two external versions: EPAD2 (serial/
USB output) and CPAD2 (CAN bus output).
The best news is that most Dewetron systems are compatible with all these kinds of signal conditioners, so you can create a system with exactly what you need today - and add more later, as required!
ePAD2 series modules
Multi-channel, isolated, slow signals
Serial output
CPAD2 series modules
Multi-channel, isolated, slow signals
CAn output
Dewetron ProDUCt SeLeCtIon GUIDe
59
DEwETRON SIgNAL CONDITIONERS - DAQ SERIES...
MODuLE INPuT TyPE RANgES TEDS
BANDwIDTh (Bw) fILTERS (LP / hP)
High Voltage Measurement
DAQP-HV
V
High voltage
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
N/A
DAQP-HV-S3
V
DAQP-DMM
V
High voltage
High voltage
Low/Medium Voltage & Current Measurement
DAQP-LV Voltage, current with external shunt or current sensor
V
IEPE via MSI-V-ACC
PT100, Pt200, Pt500,
Pt1000, Pt2000 and resistance via MSI-V-RTD
DAQP-V
V
Voltage, current with external shunt or current sensor
DAQP-LA-SC
Current
Note: 5Arms continuous
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
±10, ±40, ±100, ±200, ±400, ±1000 V N/A
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10, ±25, ±50 V
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10 V
N/A
-200 to 1000 C and 0 to 6.5 kΩ
±10, ±100 mV
±1, ±5, ±10, ±50 V
±0.1, ±0.3, ±1, ±3 A
±10 A peak, ±30 A peak max 5Arms continuous current
N/A
N/A
N/A
DAQP-LA-B
Current
Note: intended for 4-20 mA applications
±2, ±6, ±20 mA
±60 mA, ±200 mA, ±0.6A max 0.6 A
N/A
Bridge / Strain Gage Measurement
DAQP-STG
DAQP-BRIDGE-A
DAQP-BRIDGE-B
DAQP-CFB
60
Strain gages, bridge sensors, voltages
Pot./Ohmic sensors
Thermocouple via MSR-
BR-TH series
Strain gages, bridge sensors
Pot./Ohmic sensors
Thermocouple via MSR-
BR-TH series
Strain gages, bridge sensors
Pot./Ohmic sensors
Thermocouple via MSR-
BR-TH series
AC bridge, strain gage, carrier sensors
Bridge:full, half, quarter bridge
Voltage: up to ±10 V
Resistance/Ω: up to 10 kΩ
J, K, T and C types
±1, ±2, ±5, ±10, ±20, ±50 mV/V
(@ 5 Vdc excitation)
200 ohm to 10 kohm
Full range of thermocouple type
±0.1, ±0.2, ±0.5, ±1, ±2, ±5, ±10,
±20, ±50, ±100 mV/V
(@ 5 Vdc excitation)
200 ohm to 10 kohm
Full range of thermocouple type
Bridge: 0.1 to 1000 mV/V
Inductive: 5 to 1000 mV/V
Inductive/ LVDT sensors Voltage: 0.2 to 1000 mV/vrms
Dewetron ProDUCt SeLeCtIon GUIDe
N/A
Yes
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
BW: 700 kHz
BW: 20/30 kHz
LP: 10, 100, Hz
1, 2, 20/30 kHz
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
BW: 50 kHz
LP: 10, 100 Hz
1, 10, 50 kHz
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
BW: 20 kHz
LP: 10, 100 Hz
1, 5, 20 kHz
BW: 200 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 200 kHz
BW: dc to 2.3 kHz
LP: 10, 30, 100, 300 Hz
1 kHz
ISOLATION (ISO)
OVER-VOLTAgE PROTEC-
TION (OP)
ISO: 1.8 kVrms (lineto-line)
ISO: 1.8 kVrms (lineto-line)
ISO: 1.5 kVrms
ISO: up to 1 kVrms
(with banana jacks)
OP: 350 VDC
ISO: up to 1 kVrms
OP: ±500 VDC or 350
Vrms
ISO: 1.4 kVrms
ISO: 1.4 kVrms
ISO: 350 VDC
OP: ±10 VDC
ISO: 350 VDC
OP: ±50 VDC
ISO: N/A
OP: ±10 VDC
ISO: N/A
OP: ±10 VDC
MODuLE INPuT TyPE RANgES
Charge/IEPE Measurement
DAQP-ACC-A
IEPE sensors
±50, ±166, ±500 mV; ±1.66, ±5 V
(Gain: 1, 3, 10, 30, 100)
Yes
DAQP-CHARGE-A
IEPE and charge sensors
Note: selectable integration and double integration
DAQP-CHARGE-B
Charge sensors
Note: selectable time constant for static charge sensors
Temperature and Universal Measurement
DAQP-MULTI
Thermocouple (universal)
V
RTD
Voltage
Resistance
Bridge (constant current)
Charge: 5, 50, 500, 5000, 50000 pC
IEPE: ±5, ±50, ±500 mV, ±5 V
(0, 20, 40, 60 dB)
±100, ±500, ±2 000, ±10 000,
±40 000, ±200 000, ±1 000 000 pC
K, J, T, R, S, N, E, B, L, C, U type, internal linearization, freely programmable range, internal CJC
Pt100, Pt200, Pt500, Pt1000 and
Pt2000 sensors, programmable range
(2-wire and 4-wire only)
10 ranges from ±5 mV to ± 5 V freely programmable range from 1
Ohm to 1 MOhm
4-wire full bridge sensors, 13 ranges from ±0.5 to 5000 mV/mA
DAQP-THERM
Thermocouple (universal)
K, J, T, R, S, N, E, B, L, C, U freely programmable within the maximum range of the selected thermocouple type, internal linearization, internal CJC
Frequency to Voltage Measurement
DAQP-FREQ-A
Frequency to voltage
100, 1k, 5k, 20k, 100k and 200 kHz ranges;
Trigger level range 0 to 130 V,
Additional TTL output (isolated pulse output of input signal)
Output Modules
DAQN-V-OUT
OUT
Analog output
1:1 output module, from 0 to ±10 V
Accuracy ±0.05 %
Connector choices: banana, BNC, or
9-pin DSUB connector
N/A
N/A
Yes
N/A
N/A
N/A
TEDS
BANDwIDTh (Bw) fILTERS (LP / hP)
BW: 400 Hz
ISOLATION (ISO)
OVER-VOLTAgE PROTEC-
TION (OP)
BW: 0.5 Hz to 300 kHz
LP: 1, 10, 100, 300 kHz
HP: 0.5 Hz, 5 Hz
BW: 0.1 Hz to 50 kHz
LP: 100 Hz; 1, 3, 10, 50 kHz
HP: 0.1 Hz, 1 Hz, 10 Hz
BW: 0.5 Hz to 100 kHz
LP: 10, 30, 100, 300 Hz;
1, 3, 10, 30, 100 kHz
HP: DC, 0.0001 Hz to
0.5 Hz
N/A
N/A
ISO: 350 VDC
BW: 3 kHz
LP: 3Hz, 10 Hz, 30 Hz, 100
Hz, 300 Hz, 1 kHz
Butterworth or Bessel;
2nd, 4th, 6th, or 8th order programmable
ISO: 1000 Vrms continuous (for input, excitation and TEDS interface)
BW: 3 kHz
LP: 3Hz, 10 Hz, 30 Hz, 100
Hz, 300 Hz, 1 kHz
Butterworth or Bessel;
2nd, 4th, 6th, or 8th order
(programmable)
ISO: ±1000 Vrms continuous
BW: 200 kHz
Selectable input and output filters (range-dependent)
ISO: 350 VRMS
ISO: CMV output to input, continuous: 1500
VRMS max
Dewetron ProDUCt SeLeCtIon GUIDe
61
DEwETRON SIgNAL CONDITIONERS - hSI SERIES...
HSI modules are a whole new series with 1~2 MHz bandwidth, with the same form factor as DAQ and PAD series modules. The first three HSI modules are the STG (universal), the
HV (high voltage) and LV (low voltage). You can plug them into normal DAQ slots and they will work although with a 300 kHz max bandwidth. Or order a new system with the faster backplane.
MODuLE INPuT TyPE RANgES TEDS
BANDwIDTh (Bw) fILTERS (LP / hP)
ISOLATION (ISO)
OVER-VOLTAgE PROTEC-
TION (OP)
High Voltage Measurement
HSI-HV
V
High voltage
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
N/A
Low/Medium Voltage & Current Measurement
HSI-LV
V
Voltage, current with external shunt or current sensor
IEPE via MSI-V-ACC
PT100, Pt200, Pt500,
Pt1000, Pt2000 and resistance via MSI-V-RTD
Bridge / Strain Gage Measurement
HSI-STG
Strain gages, bridge sensors, voltages
Pot./Ohmic sensors
Thermocouple via MSR-
BR-TH series
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10, ±25, ±50 V
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10 V
N/A
-200 to 1000 C and 0 to 6.5 kΩ
Bridge: full, half, quarter
Voltage: Up to ±10V
Resistance/Ω: up to 10 kΩ
J, K, T and C types
BW: 2 MHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
1, 2 MHz
ISO: 1.8 kVrms
(line-to-line)
BW: 2 MHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
1, 2 MHz
ISO: up to 1 kVrms
(with banana jacks)
OP: 350 VDC
BW: 2 MHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
1 MHz
ISO: 350 VDC
OP: ±10 VDC
ADDITIONAL ADAPTERS
ADAP-BrIDGe-1/4-120
120 Ω, 1/4 bridge completion adapter, for
MDAQ-SUB-BRIDGE-D,
DEWE-43- DEWE-101
ADAP SERIES ADAPTERS fOR A VARIETy Of APPLICATIONS
ADAP-MDAQ-BnCF ADAP-DAQ-BnCF
BNC to DB9 adapter for
MDAQ with DB9 connectors, DEWE-43, DEWE-101,
DEWE-3143...
ADAP-BrIDGe-1/4-350
ADAP-SHUnt-50-BnC
350 Ω, 1/4 bridge completion adapter, for
MDAQ-SUB-BRIDGE-D,
DEWE-43- DEWE-101
50 Ω shunt adapter for 4-20 mA measurements (0.1%,
1 W). BNC input connector and DB9 output connector.
ADAP-SHUnt-100-BnC
ADAP-BrIDGe-1/2-120
ADAP-Conn-DSUB-9
ADAP-BrIDGe-1/2-350
120 Ω, 1/2 bridge completion adapter, for
MDAQ-SUB-BRIDGE-D,
DEWE-43- DEWE-101
350 Ω, 1/2 bridge completion adapter, for
MDAQ-SUB-BRIDGE-D,
DEWE-43- DEWE-101
ADAP-XLr-BnC
DB9 connector with convenient screw terminals inside for easy hook up without soldering. (Shown opened here)
ADAP-BAn-BnC
ADAP-1032-BnC
Adapter from mic XLR connector to BNC output connector, includes short
BNC cable
Images are figurative and may not exactly match the actual appearance
62
Dewetron ProDUCt SeLeCtIon GUIDe
BNC to DB9 adapter for
DAQ and HSI modules with
DB9 connectors, such as
DAQP-LV-D, DAQP-V-D,
HSI-LV-D
100 Ω shunt adapter for 0-5
A measurements (0.1%, 1
W). BNC input connector and DB9 output connector.
Banana jack inputs to BNC output connector
10-32 Microdot input to
BNC output, compatible with DAQP-ACC-A,
MSI-BR-ACC, MDAQ-SUB-
ACC, DAQP-CHARGE...
MSI MuLTI SENSOR INTERfACES...
MSI MuLTISENSOR INPuTS fOR hSI, DAQ, AND MDAQ MODuLES
HSI-STG DAQP-STG
MDAQ-SUB-
STG-D
MDAQ-SUB-
BRIDGE-D
DAQP-
BRIDGE-A
DAQP-
BRIDGE-B
HSI-LV-D DAQP-LV-D
MDAQ-SUB-
V-200-D
Constant current (IEPE) adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Excitation current 4 mA at 21V. high-pass filter 1.5 Hz, BNC input connector. Bandwidth, ranges, and isolation are determined by the module that it is plugged into.
Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
MSI-BR-ACC
MSI-V-ACC
MSI-BR-V-200
MSI-BR-RTD
MSI-V-RTD
MSI-BR-CHA-50
Yes
--
Yes
--
--
--
--
--
--
--
--
--
--
Yes
--
Yes Yes
±200 V adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Differential input configuration, BNC input connector. Bandwidth, ranges, and isolation are determined by the module that it is plugged into. Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
Yes Yes Yes Yes ------
RTD adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Compatible with Pt100, Pt200, Pt500, Pt1000, Pt2000 via 2, 3 and 4-wire connection methods.5-pin BINDER series 710 input connector (mate included). Bandwidth, ranges, and isolation are determined by the module that it is plugged into. Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
Yes
--
Yes
--
Yes
--
Yes
--
--
--
--
--
--
Yes
--
Yes
--
Yes
CHARGE sensor adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Dynamic input configuration, BNC input connector. Bandwidth, ranges, and isolation are determined by the module that it is plugged into. Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
Yes Yes Yes Yes ------
MSI-BR-TH-K
MSI-BR-TH-J
MSI-BR-TH-T
Thermocouple sensor adapter for certain Dewetron modules with DB9 input connector required (see compatibility matrix below).
Available in types J, K, and T (color coded). Standard mini T/C input connector jack (female). Bandwidth, ranges, and isolation are determined by the module that it is plugged into. Automatic MSI identification in DS-7 software (TEDS cannot then be used for sensor identification when an MSI is used).
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
* Automatic MSI identification is not supported by the DAQP-BRIDGE-A.
Yes
Yes
Yes
Yes*
Yes*
Yes*
--
--
--
--
--
--
--
--
--
--
--
--
CAN BuS ISOLATORS AND ADAPTERS
ADAP-CAn-HI-Low
Adapter from high speed
CAN (ISO 11898-2) to low speed CAN (ISO 11898-3)
ADAPTERS fOR CAN BuS
ADAP-CAn-HI-Sw
Adapter from high speed
CAN (ISO 11898-2) to single wire CAN (SAE
J2411)
ADAP-CAn-ISo
Images are figurative and may not exactly match the actual appearance
Isolator for CAN bus interfaces (any type)
Dewetron ProDUCt SeLeCtIon GUIDe
63
DEwETRON SIgNAL CONDITIONERS - MDAQ SERIES...
ANATOMy Of AN MDAQ MODuLE...
MDAQ modules are factory installed within your
Dewetron system. From the outside you see only the input connectors. But inside, there is a
BASE card which can hold any two 8-channel
MDAQ-SUB modules on one side, and any
MDAQ-FILT filter card on the other side. The result is a system which can be configured to suit a wide variety of applications.
toP: MDAQ-SUB MoDULeS (2)
MIDDLe: MDAQ-BASe MoDULe
BottoM: MDAQ-FILt (oPtIonAL)
SUB Modules for MDAQ-BASE-x
Module
MDAQ-SUB-STG-D
Connector: DB-9
V
MDAQ-SUB-BRIDGE-D
Connector: DB-9
V
MDAQ-SUB-V-200-D
Connector: DB-9
V
MDAQ-SUB-V-200-BNC
Connector: BNC
# CH Input type
8
* Strain-gage (Full-, half and quarter-
bridge, incl. shunt calibration)
for strain gage application:
* Voltage up to ±10 V:
* ICP via MSI-BR-ACC:
* Voltage up to 200 V via MSI-BR-V-200:
* Thermocouple via MSI-BR-TH-x:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-BR-RTD:
8
* Strain-gage (Full-, and half bridge)
for strain gage sensors:
* Voltage up to ±10 V:
* ICP, via MSI-BR-ACC:
* Voltage up to 200 V via MSI-BR-V-200:
* Thermocouple via MSI-BR-TH-x:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-BR-RTD:
Input ranges
14 ranges from ±0.5 to 1000 mV/V
(@ 5 V
DC
excitation
15 ranges from ±2.5 mV to ±10 V
7 ranges from ±0.25 mV to ±10 V
6 ranges from ±10 to ±200 V full range of TC type
-200 °C to 1000 °C and 0 to 6.5 kOhm
14 ranges from ±0.5 to 1000 mV/V
(@ 5 V
DC
excitation
15 ranges from ±2.5 mV to ±10 V
7 ranges from ±0.25 mV to ±10 V
6 ranges from ±10 to ±200 V full range of TC type
-200 °C to 1000 °C and 0 to 6.5 kOhm
8
* Voltage up to ±200 V:
* ICP, via MSI-V-ACC:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-V-RTD:
Note: for safety reasons, max. 120 V
DC
or 50 V
13 ranges from ±0.125 to ±200 V
7 ranges from ±0.25 mV to ±10 V
-200 °C to 1000 °C and 0 to 6.5 kOhm
AC
are allowed at this connector
8
* Voltage up to ±200 V:
13 ranges from ±0.125 to ±200 V
V
Note: for safety reasons, max. 120 V
DC
or 50 V
AC
are allowed at this connector
MDAQ-SUB-ACC-BNC
Connector: BNC
MDAQ-SUB-ACC-A-BNC
Connector: BNC
MDAQ-SUB-ACC-A-MD
Connector: Microdot
8
* ICP ® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended or differential input and one highpass filter
3.4 Hz highpass filter for noise and shock response measurement
MDAQ-SUB-ACC-BNC-S1
0,16 Hz for structural and modal analysis, human body vibration measurement
(rest same as MDAQ-SUB-ACC-BNC)
8
* ICP ® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended input and two HP filters
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
8
* ICP ® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended input, two HP filters and sensor failure detection
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
Option: test signal input for all channels
■ BW: 30 kHz
■ BW: 30 kHz
HP: 0.16 Hz
■ BW: 300 kHz
-
BW: 300 kHz
■ BW: 300 kHz
HP: 3.4 Hz
■ BW: 300 kHz
HP: 0.16 Hz
-
0 to 12 V
DC
+15 V
DC
and
0 to 12 V
DC
±15 V
DC
and
0 to 12 V
DC
4 / 8 mA
4 / 8 mA
■ BW: 300 kHz
HP: 0.16 Hz, 3.4 Hz
4 / 8 mA
■ BW: 300 kHz
HP: 0.16 Hz, 3.4 Hz
4 / 8 mA
64
Dewetron ProDUCt SeLeCtIon GUIDe
MDAQ-fILT OPTIONS
Filter modules for MDAQ
Module
MDAQ-AAF4-5-BU
MDAQ-FILT-5-BU
MDAQ-FILT-5-BU-S1
MDAQ-FILT-5-BE
16
16
# CH
16
16
Filter characteristics
Butterworth
Butterworth
Cut-off frequencies
100 Hz, 1, 10, 30, 100 kHz, Bypass
Note: not possible in all system configurations.
Please contact factory for details.
30, 100, 300 Hz, 1, 10 kHz, Bypass
Butterworth
Bessel
100 Hz, 1, 10, 30, 100 kHz, Bypass
30, 100, 300 Hz, 1, 10 kHz, Bypass
2 nd
2 nd
Order
4 th
2 nd
MDAQ modules - available in most of the
DEWETRON multichannel systems.
The DEWE-501 can accept up to 8 MDAQ-SUB conditioners, for 64 dynamic input channels
Typical combination with two SUB modules mounted on a BASE module, and
FILTER board (optional)
All MDAQ boards are equipped with highest quality components
Dewetron ProDUCt SeLeCtIon GUIDe
65
DEwETRON SIgNAL CONDITIONERS - PAD SERIES...
PAD
that stands for “programmable A/D” module. Although PAD modules share the form factor of the DAQ series, they have their own ADCs on board, and output digitally via the serial bus that is built into each slot in a Dewetron system (the same bus that is used to control the DAQ and MDAQ modules). our most popular PAD modules are the PAD-tH8-P, an outstanding 8 channel thermocouple module. Just plug in the breakout box of your choice - we have PAD-
CB8 breakout boxes for types J, K, and t thermocouples, as well as rtD temperature sensors. there are several more PAD modules, like the PAD-V8-P which provides 8 voltage inputs, and others. If you don’t want to block an analog input in your system with a PAD module, go for the ePAD2 or CPAD2 series eXternAL PAD modules, as shown on the opposite page.
MODULE
PAD-V8-P
V
PAD-TH8-P
CHS ADC
8
PAD SERIES PLug-IN MODuLES (ALL hAVE DIgITAL OuTPuTS)
SAMPLE
RATE
24-bit 6 S/s/ch
ISOLATION
350 V
RANGES
±100 mV .. ±50V
BREAK-OUT BOX
PAD-CB8-BNC
PAD-CB8-B
V
PAD-AO1
8 24-bit 6 S/s/ch 350 V
According to the thermocouple or RTD breakout box connected
PAD-CB8-J-P2
PAD-CB8-K-P2
PAD-CB8-K-M
PAD-CB8-T-P2
PAD-CB8-RTD
1 16-bit 1 Hz --
0 .. 10 V or
0 .. 20 mA (500 ohm load)
--
OUT
PAD-DO7
RELAY
7 N/A 1 Hz --
AC 120 V @ 0.5 A
DC 24 V @ 1 A
--
DSUB25 connector is on the front of the PAD module. Use either a mating connector or a breakout box to connect signals
ADD’L FEATURES
20mA measurement with external shunt resistor
Automatic identification of breakout box; sensor lead wire break detection
--
Drives up to 7 relays
Break-oUt Boxes for PaD-th8-P, ePaD-th8-P, CPaD-th8-P onlY:
PAD MODuLE BREAk-OuT BOXES
Voltage
INPUT TYPE MODEL
PAD-CB8-BNC
DESCRIPTION
8 channel voltage break-out box, with BNC connectors
CABLE
2 meters (extensions available)
PAD-CB8-B 8 channel voltage break-out box, with BNC connectors
Thermocouples PAD-CB8-K-M
PAD-CB8-K-P2
PAD-CB8-J-P2
PAD-CB8-T-P2
Mini thermocouple break-out, 8 chs, type K only
Thermocouple break-out box, 8 type K inputs, type K
Thermocouple break-out box, 8 type K inputs, type J
Thermocouple break-out box, 8 type K inputs, type T
2 meters (extensions available)
RTD sensors
PAD-CB8-RTD Pt100, Pt200, Pt500 (up to 250°C) and NI120 sensors
2 meters (extensions available)
PAD-CB8-RTD-S3 Pt100, Pt200, Pt500, Pt1000 and Pt2000 sensors
CONNECTORS
DSUB25
DSUB25
DSUB25
DSUB25
COMPATIBLE WITH
PAD-V8-P
EPAD-V8-P
PAD-TH8-P
EPAD-TH8
PAD-TH8-P
EPAD-TH8
PAD-CB8-K-M
66
Dewetron ProDUCt SeLeCtIon GUIDe
PAD-CB8-BnC AnD -B
PAD-CB8-rtD
EPAD2 SERIES (RS485 INTERfACE)
CHS ADC
EPAD SERIES EXTERNAL MODuLES (ALL hAVE DIgITAL OuTPuTS)
ISOLATION /
PROTECTION
S/R RANGES
BREAK-OUT
BOX(ES)
INPUT TYPE
EPAD2-V8-LEMO
V
EPAD2-LA8-LEMO
8 24-bit
ISO: 350 VDC
OV: 150 VDC
12 S/s/ch ±0.1, 0.15, 0.5, 1, 2.5, 5, 10, 50 V N/A
8 24-bit ISO: 350 VDC 12 S/s/ch ±30 mA N/A
EPAD2-TH8-K, J, T
8 24-bit
ISO: 350 VDC
12 S/s/ch
-270°C to 1372°C
-210°C to 1200°C
-270°C to 400°C
N/A
ADD’L FEATURES
SIGNAL
CONNECTOR(S)
LEMO EGG.1B.304
DIN mounting option
EPAD2 boxes connect together via captive fasteners
Sensor disconnection or interruption detection
LEMO EGG.1B.304
Std mini T/C type, color coded
EPAD2-RTD8-LEMO
8 24-bit
ISO: 350 VDC
12 S/s/ch
2- or 4-wire Pt100, Pt200, Pt500,
Pt1000 and NI120 sensors
N/A
LEMO EGG.1B.304
ePAD2-tH8-J/K/t modules have thermocouple connectors already and do not require a thermocouple break-out box ePAD2-rtD8-LeMo (top) and ePAD2-tH8
(bottom)
DIn rAIL mount option ePAD2-tH8-K ePAD-BASe2 allows you to connect ePAD2 modules to any computer via USB or CAn BUS
... CPAD2 SERIES (CAN BuS INTERfACE)
MODULE
CPAD2-TH8-K, J, T
V
CPAD2-RTD8-LEMO
CHS ADC
8
8
24-bit
24-bit
CPAD2 SERIES EXTERNAL MODuLES (ALL hAVE DIgITAL CAN BuS OuTPuTS)
ISOLATION SAMPLE RATE RANGES
BREAK-OUT
BOX
ADD’L FEATURES
K: -270°C to 1372°C
J: -210°C to 1200°C
350 VDC 12 S/s/ch (Not required)
T: -270°C to 400°C
350 VDC 12 S/s/ch
2- or 4-wire Pt100,
Pt200, Pt500, Pt1000 and NI120 sensors
(Not required)
DIN mounting option
CPAD2 boxes connect together via captive fasteners
Sensor disconnection or interruption detection
CPAD2-LA8-LEMO
8 24-bit 350 VDC 12 S/s/ch
4 to 20 mA current sensors
(Not required)
SIGNAL
CONNECTOR(S)
Std mini T/C type, color coded
LEMO EGG.1B.304
RS-485 interface,
LEMO EGG.1B.304
RS-485 interface,
CPAD2-tH8-J/K/t modules have thermocouple connectors already and do not require a break-out box
Dewetron ProDUCt SeLeCtIon GUIDe
67
orIon series A/D cards
Zt series SCoPe cards
SPeCtrUM series trAnSIent cards
Dewetron A/D cards
http://www.dewamerica.com/Products/ADcards/
OVERVIEw
All ORION series cards are SIMULTANEOUS SAMPLING - no multiplexing! ORION Cards are available with 16, 22, and 24-bit resolution.
The 22 and 24-bit cards have sigma-delta ADCs, which are ideal for dynamic measurements such as noise and vibration, due to their powerful anti-aliasing filters on board, dynamic range, and tremendous vertical axis resolution.
Our 16-bit ORION cards employ successive approximation ADCs, and are ideally suited for a wide range of applications in electrical testing, power testing, and much more. All ORION cards feature at least 2 synchronous counter/encoder inputs and 8 digital I/O lines, and more are optionally available -- including higher voltage input levels and programmable detection levels up to 40V.
In addition, two synchronous CAN BUS interfaces can be installed on any ORION card.
Note: for our TRION modules, please see the DEWE2 section of this catalog. These are plug-in modules that combine an ORION card with top-quality signal conditioners.
◙
◙
◙
◙
◙
◙
◙
◙
◙
ORION CARDS:
Simultaneous sampling
Built-in counter/encoder inputs
Built-in digital I/O lines
Optional CAN BUS interfaces
Expandable and synchronizable
16, 22, and 24-bit
ISO9001, ISO14001
CE Mark
◙
◙
◙
◙
OTHER AVAILABLE CARDS:
SCOPE cards for PC-based oscilloscope applications up to 4 GHz
SPECTRUM series TRANSIENT cards for 10-200 MHz performance
DA series cards for analog outputs
68
Dewetron ProDUCt SeLeCtIon GUIDe
ORION CARDS: 16-BIT VERSIONS
ORION SERIES A/D CARDS wITh 16-BIT RESOLuTION
CARD
ORION-1616-100
CHS
16
ADC
16-bit
MAX SAMPLE
RATE (B/W)
100 kS/s/ch
(B/W 50 kHz)
INPUT RANGES
±1.25, ±2.5, ±5, ±10 V
CNT/ENC
2
ORION-1616-500
ORION-1616-1000
ORION-3216-100
16
16
32
16-bit
16-bit
16-bit
500 kS/s/ch
(B/W 250 kHz)
1 MS/s/ch
(B/W 600 kHz)
100 kS/s/ch
±1.25, ±2.5, ±5, ±10 V
±1.25, ±2.5, ±5, ±10 V
±1.25, ±2.5, ±5, ±10 V
2
2
2
orIon cards feature on-board rS485 for direct control of the Dewetron signal conditioning modules
DI/O MODELS AND OPTIONS
16 (8/8) 100
101
102
Standard version
Adds 2 CAN bus interface
+ 8 TTL DI lines with 25 VDC protection
+ 8 more TTL CNT/ENC or 32 TTL DI/O
103
104
Same as -102 plus 2 CAN bus interfaces
8 TTL DI lines 25 VDC protection
+ 8 adjustable CNT/ENC or +32 more TTL DIs (with programmable threshold levels (0..40 V), input voltage range -35 to 60 V, AC/DC coupling)
105 Same as -104 plus 2 CAN bus interfaces
16 (8/8) Same options as ORION-1616-100 series
16 (8/8)
16 (8/8)
Same options as ORION-1616-100 series
100 = standard version, 101 adds 2 CAN bus interfaces
Convenient break-out boxes are available for many orIon cards
A wide range of orIon cards are available, from 100 kS to 1 MS/s/ch (simultaneous), and with resolutions of 16, 22, and 24-bits.
ORION CARDS: 24-BIT VERSIONS
ORION SERIES A/D CARDS wITh 24-BIT RESOLuTION
CARD CHS ADC
MAX SAMPLE
RATE (B/W)
ORION-1624-200 16 24-bit 204.8 kS/s/ch
(B/W 76 kHz)
INPUT RANGES
±10 V
CNT/ENC
2
DI/O
16 (8/8) 200
201
202
203
204
ORION-0824-200 8 24-bit 204.8 kS/s/ch
(B/W 76 kHz)
±0.1, ±0.5, ±2, ±10
V, voltage or IEPE mode, TEDS support, single-ended or differential configuration, AC (0.15 or
3.4 Hz) or DC coupled
2
ORION-0424-200 4 24-bit 204.8 kS/s/ch
(B/W 76 kHz)
±0.1, ±0.5, ±2, ±10
V, voltage or IEPE mode, TEDS support, single-ended or differential configuration, AC (0.15 or
3.4 Hz) or DC coupled
1
orIon cards feature on-board rS485 for direct control of the Dewetron signal conditioning modules
205
16 (8/8) 200
201
TRG input only (no
DIO)
202
203
204
205
200
MODELS AND OPTIONS
Standard version
Adds 2 CAN bus interface
+ 8 more TTL DI lines 25 VDC protection
+ 8 more advanced TTL CNT/ENC or 32 TTL DI/O
Same as -102 plus 2 CAN bus interfaces
8 TTL DI lines 25 VDC protection
+ 8 adjustable CNT/ENC or +32 more TTL DIs (with programmable threshold levels (0..40 V), input voltage range -35 to 60 V, AC/DC coupling)
Same as -104 plus 2 CAN bus interfaces
Standard version
(same as -201 above)
(same as -202 above)
(same as -203 above)
(same as -204 above)
(same as -205 above)
Standard version, 4 BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support
SUB-D-9 connector with one advanced CTR/ENC with programmable threshold levels (0..40 V), input voltage range -35 to 60 V, AC/DC coupling, plus one external trigger input
69
Dewetron ProDUCt SeLeCtIon GUIDe
ORION CARDS: 22-BIT VERSIONS
ORION SERIES A/D CARDS wITh 24-BIT RESOLuTION
CARD
ORION-1622-100
CHS
16
ADC
MAX SAMPLE
RATE (B/W)
22-bit 102.4 kS/s/ch
(50.1 kHz)
INPUT RANGES
±10 V
CNT/ENC
2
DI/O MODELS AND OPTIONS
16 (8/8) 100
101
Standard version
Adds 2 CAN bus interface
102 + 8 more TTL DI lines 25 VDC protection
+ 8 more advanced TTL CNT/ENC (or +32 more
TTL DI/Os)
Same as -102 plus 2 CAN bus interfaces 103
104 8 TTL DI lines 25 VDC protection
+ 8 adjustable CNT/ENC or +32 more TTL DIs (with programmable threshold levels (0..40 V), input voltage range -35 to 60 V, AC/DC coupling)
105 Same as -104 plus 2 CAN bus interfaces
16 (8/8) 100 = standard version, 101 adds 2 CAN bus interfaces ORION-3222-100 32 22-bit 102.4 kS/s/ch
(50.1 kHz)
±10 V 2
orIon cards feature on-board rS485 for direct control of the Dewetron signal conditioning modules
aDvanCeD CoUnter inPUts
Dewetron ORION cards feature powerful counter inputs that can handle a wide range of frequency inputs, from simple tach outputs to full quadrature encoders with hundreds or even thousands of steps per revolution. Our counters run at very high speed in the background, regardless of the analog sample rate, so you will get great performance all the time.
DS-7 even features a counter/tach design screen so that you can define and save your own counter/encoder “sensors,” and apply them to any counter in any setup.
The -x04 and -x05 versions of ORION cards offer even wider input ranges for your counter/tach signals, to handle more demanding sensors.
◙
◙
◙
◙
◙
Advanced counter functions:
◙ Event Counting
◙
◙
Gated Event Counting
Up/Down Counter
Frequency Measurement
Period Time Measurement
Pulse Width Measurement
Two Pulse Edge Separation
Quadrature Encoder (X1, X2, X4, A-Up/B-Down)
Da series CarDs for analog oUtPUt
ANALOG OUTPUTS are sometimes needed in systems to either replay data back out to another display or device in the analog realm, or to generate one or more waveforms during measurement, in order to drive a small shaker or to otherwise create an excitation that the system will also record.
When you add any D/A option, you also need the software option called DS-OPT-FG for 2 channel cards, or DS-OPT-FG-PROF for cards with more than 2 channels. Up to 16 total DA channels are supported. A connector PANEL or breakout box is also needed to access the outputs.
DA-0216-750
16-channels, 16-bit, 750 kS/s/ch
DA4-1000-16
4-channels, 16-bit, 1000 kS/s/ch
DA8-1000-16
16-channels, 16-bit, 1000 kS/s/ch
DA8-CB-BNC
8 channel break-out box for DA4/8 cards above with BNC’s
70
Dewetron ProDUCt SeLeCtIon GUIDe
ZT CARDS fOR SCOPE SySTEMS
ZT SERIES SCOPE A/D CARDS
Card Chs
Max sample rate
ZT4431 2
500 MS/s/ch
ZT4432 4
ZT4441
ZT4442
2
4
800 MS/s/ch
Bit resolution
13-bits
13-bits
Bandwidth Max. Input @ 50 Ω
300 MHz
300 MHz
ZT4211 2
ZT4212 4
1 GS/s/ch 8-bits 300 MHz
±5 V (DC + peak
AC), CAT II Input load protection @
±6 VDC
ZT4421 2
1 GS/s/ch 12-bits 300 MHz
ZT4422 4
Std
RAM
256 MS
512 MS
256 MS
512 MS
256 MS
512 MS
Trig lines
2
2
INPUT Z Coupling
1 MΩ ||
12 pF or
50 Ω
AC or DC
1 MΩ ||
12 pF or
50 Ω
AC or DC
256 MS
2
1 MΩ ||
12 pF or
50 Ω
AC or DC
512 MS
ZT4611
ZT4612
ARB waveform generator
2
4
CHS
4 GS/s/ch
MAX Output
Rate
8-bit
Bit Resolution
1 GHz
Bandwidth
(-3 dB)
Output Z
64 MS
128 MS
Ch/Ch
ISO.
2
Waveform Length
AC or DC
Output
Limit
ZT5211
ZT5212
2
4
200 MS/s/ch 14-bits 50 MHz 50 Ω ≥60 dB
4 Samples to 32
MSamples/channel
≤ 7V into
50Ω
Operation modes: Continuous, Burst, Binary modulation, Sweep. Trigger functions: External, internal, and software. Trigger modes: Edge & Pattern.
Max input @ 1 MΩ input Z
±210 V [DC + peak
AC (<100 kHz)], CAT
I Peak AC, de-rated
20 dB/decade above
100 kHz
±300 V [DC + peak
AC (<100 kHz)], CAT
I Peak AC, de-rated
20 dB/decade above
100 kHz
±210 V [DC + peak
AC (<100 kHz)], CAT
I Peak AC, de-rated
20 dB/decade above
100 kHz
Rise/Fall Time
(@ 50 Ω)
< 7 ns for 10V step
(50 MHz Filter)
SPECTRuM CARDS fOR TRANSIENT RECORDERS
SPECTRuM SERIES TRANSIENT A/D CARDS
Card CHS
Max sample rate
M2i.4642
M2i.4651
M2i.4652
M2i.4022
M2i.4032
M2i.3121
M2i.3122
M2i.3131
M2i.3132
M2i.3024
M2I.3026
M2i.2031
8
2
1
2
8
4
4
4
8
4
8
4
1 MS/s/ch
3 MS/s/ch
3 MS/s/ch
20 MS/s/ch
50 MS/s/ch
10 MS/s/ch
10 MS/s/ch
25 MS/s/ch
25 MS/s/ch
100 MS/s/ch
200 MS/s/ch
200 MS/s/ch
Bit resolution
16-bits
14-bits
12-bits
8-bits
Bandwidth Input ranges
±200 mV to 10 V
±50 mV to ±10 V
Std
RAM
128
MS
256
MS
Trig lines
1
Options
(Available for all of these cards)
M2I.XXXX-256MS 256 MSamples memory
M2I.XXXX-512MS 512 MSamples memory
M2I.XXXX-1GS 1 GSamples memory
M2I.XXXX-2GS 2 GSamples memory
M2I.XXXX-SH5 Synchronization of up to 5 cards
(M21-XXXX-256MS already included)
Multiple Spectrum cards in the same system requires the Sync option
Dewetron ProDUCt SeLeCtIon GUIDe
71
Dewetron Interfaces
http://www.dewamerica.com/Products/Interfaces
time sYnC interfaCes
TIME SyNC INTERfACES - INTERNAL & EXTERNAL
MODEL NAME INPUTS OUTPUTS COMPATIBILITY
IRIG-CLOCK-INT
DEWE-IRIG-CLOCK Card
Pin assignment
IRIG-CLOCK-EXT
IRIG A
IRIG B
Digital clock to
A/D cards, and data via USB
2.0
Modulated or demodulated signal types (auto selection)
INPUT RANGE
0.5 Vp-p to 10 Vp-p
FORM
FACTOR
Internal PCB
Aluminum housing
RATE(S)
10 MHz max.
COMMENTS, FEATURES
Mounted inside Dewetron chassis, connects internally via USB and clock lines to A/D card and
DEWE-CAM trigger input
External, high impact housing, connects to Dewetron systems via clock input connector(s)
GPS-CLOCK-INT
DEWE-IRIG-CLOCK Card
Pin assignment
GPS-CLOCK-EXT
GPS signals
Digital clock to
A/D cards, and data via USB
2.0
NMEA standard or differential signals
Requires line of sight to GPS satellites
Internal PCB
Aluminum housing
10 MHz max.
Mounted inside Dewetron chassis. Includes high quality antenna and cable.
External, high impact housing, connects to Dewetron systems via clock input connector(s). Includes high quality antenna and cable.
Pin assignment
DEWE-CLOCK-EXT
IRIG and
GPS
Digital clock to
A/D cards, and data via USB
2.0
Mod/Demod IRIG
(auto selection)
NMEA std or differential GPS
IRIG: 0.5 Vp-p to 10
Vp-p
GPS: requires line of sight to GPS satellites
Internal PCB
Aluminum housing
Mounted inside Dewetron chassis. Includes high quality antenna and cable, plus BNC IRIG input
10 MHz max.
External, high impact housing, connects to Dewetron systems via clock input connector(s). Includes high quality antenna and cable.
viDeo interfaCes
NTSC VIDEO INPuT INTERfACE
MODEL NAME
VIDEO-FG-4
INPUT
4 x NTSC video
OUTPUTS
DirectX into DS-7
STREAMS
Four independent color video streams from standard cameras
STORAGE TYPE
Direct to DS-7, video streams are stored in
AVI or DVI format
FORM
FACTOR
PCI card, half length
RATE(S)
Std NTSC
30 fps DF for each input
COMMENTS, FEATURES
Requires DS-7-PROF or higher
Requires Core2Duo processor or higher and
S-ATA hard disks and/or RAID system
PCm interfaCe
BIT SyNC / fRAME SyNC / DECOM INTERfACE
MODEL NAME INPUT OUTPUTS
PCI-PCM-01 PCM Export PCM data to
Chapter 10 format
STREAMS
Async streams supported
FRAME FORMAT ID
Supported
FORM
FACTOR
PCI card, full length
RATE(S)
Up to 33
Mbps
COMMENTS, FEATURES
Requires DS-7-SE and OPT-PCM
(DS-7-PROF and IRIG-CLOCK-INT are required if analog data will also be acquired).
Requires Core2Duo or higher.
72
Dewetron ProDUCt SeLeCtIon GUIDe
avioniCs arinC, mil-stD-1553
BuS INTERfACES - ARINC
PCI MODEL PCIe MODEL
PCI-A429-4-T
PCI-A429-8-T
PCI-A429-16-T
PCI-A429-30-T
PCIE4L-A429-4-T
PCIE4L-A429-8-T
PCIE4L-A429-16-T
PCIE4L-A429-30-T
Description (All include 3 ft mating cable. All require DS-7 and PLUGIN-ARINC/1553 software option)
PCI Interface card with 4 Shared Tx/Rx Channels of ARINC-429 and 2 Rx/2 Tx ARINC-717 Selectable Channels
(Each 717 Rx/Tx Replaces Two 429 Channels).
PCI Interface card with 4 Shared Tx/Rx Channels of ARINC-429 and 2 Rx/2 Tx ARINC-717 Selectable Channels
(Each 717 Rx/Tx Replaces Two 429 Channels).
PCI Interface card with 8 Shared Tx/Rx Channels and 8 Rx Channels of ARINC-429 and 2 Rx/2 Tx ARINC-717 Selectable Channels
(Each 717 Rx/Tx Replaces Two 429 Channels).
PCI Interface card with 16 Shared Tx/Rx Channels and 14 Rx Channels of ARINC-429 and 4 Rx/4 Tx ARINC-717 Selectable Channels
(Each 717 Rx/Tx Replaces Two 429 Channels).
BuS INTERfACES - MIL-STD-1553
PCI MODEL
PCI-1553-1D-T
PCIe MODEL Description (All include 3 ft mating cable. All require DS-7 and PLUGIN-ARINC/1553 software option)
PCIE4L-1553-1D-T One Channel of Dual Redundant MIL-STD-1553 with Dual Function (BC/Mon or mRT/Mon) Capability
PCI-1553-2D-T PCIE4L-1553-2D-T Two Channels of Dual Redundant MIL-STD-1553 with Dual Function (BC/Mon or mRT/Mon) Capability
PCI-1553-3D-T PCIE4L-1553-3D-T Three Channels of Dual Redundant MIL-STD-1553 with Dual Function (BC/Mon or mRT/Mon) Capability
PCI-1553-4D-T PCIE4L-1553-4D-T Four Channels of Dual Redundant MIL-STD-1553 with Dual Function (BC/Mon or mRT/Mon) Capability
The standard cable included is 3 feet (~1 m) long. Longer cables optionally available.
BuS INTERfACES - ARINC & MIL-STD-1553 COMBO CARDS
PCI MODEL
PCI-ARINC-16R/0T-1553-2
PCI-ARINC-8R/0T-1553-2
Description (Both require CBL-16036 cable, CBL-16037 cable, DS-7-PROF and option PLUGIN-ARINC/1553)
A429: 16R/0T 1553: 2 channels (redundant)
A429: 8R/0T 1553: 2 channels (redundant)
BuS INTERfACES - uSB INTERfACES fOR ARINC 429, ARINC 708, AND ARINC 717
USB 2.0 MODEL
USB-ARINC-1410
USB-ARINC-1431
USB-ARINC-1440
USB-ARINC-1420
Description (Includes mating connector and USB cable (5 ft / 1.5 m), requires DS-7-PROF and option PLUGIN-ARINC/1553)
ARINC 429 interface: 1R & 1T in a small USB module
ARINC 429/717 interface: ARINC 429: 8R & 4T; ARINC 717: 2R & 2T in a small USB module
ARINC 429 interface: 12R & 4T in a small USB module
ARINC 429 interface: 4R & 2T in a small USB module
Note - there are additional models available for ARINC 708 and ARINC 717. Please ask your Dewetron rep.
BuS INTERfACES - uSB INTERfACES fOR MIL-STD-1553
USB 2.0 MODEL
USB-1553-1110
USB-1553-1111
Description (Includes mating connector and USB cable (5 ft / 1.5 m), requires DS-7-PROF and option PLUGIN-ARINC/1553)
MIL-STD-1553 interface: 1 dual redundant monitor-only channel, in a small USB module
MIL-STD-1553 interface: 2 dual redundant monitor-only channels, in a small USB module
USB-1553-1140 MIL-STD-1553 interface: 3 dual redundant monitor-only channels, in a small USB module
Note - there are additional models available for MIL-STD-1553. Please ask your Dewetron rep.
Can BUs interfaCes
To add CAN BUS interfaces to your system, order the appropriate version of ORION card. ORION cards ending in odd numbers have
2 synchronous CAN BUS interfaces. No additional hardware needs to be installed! ORION CAN bus interfaces are therefore 100% synchronous with the analog inputs.
flexraY interfaCe
BIT SyNC / fRAME SyNC / DECOM INTERfACE
Model Name
PCI-FLEXRAY
Description
PCI card with one FLEXRAY interface (Requires DS-7-PROF and PLUGIN-FLEXRAY). This interface is factory installed. A DSUB connector will be brought out to one of the outside panels for easy connection of your Flexray signal.
Dewetron ProDUCt SeLeCtIon GUIDe
73
Dewetron Sensors
http://www.dewamerica.com/Products/Sensors
OVERVIEw
There are literally tens of thousands of sensors which are compatible with Dewetron’s world-class data acquisition systems.
We don’t sell all of them obviously, but there are a few key sensors that we either manufacture ourselves, or offer here for your convenience.
There are some specialty sensors that we make ourselves, as well as some standardized sensors like accelerometers and thermocouples, which we have chosen specificially to match our signal conditioning.
You can be confident that any sensor that you purchase from
Dewetron will be a perfect fit with your Dewetron system, according to the compatibility information here.
Sensors are the first link the signal chain. Like every link, they are vital to excellent data recordings. Every link in the chain is important, from the sensors to the signal conditioners, A/D converters, and the software. A data acquisition system is only as strong as its weakest link.
◙
◙
◙
◙
◙
◙
◙
◙
Tens of thousands of sensors are compatible with every Dewetron system, from thousands of manufacturers
Several key sensors are available directly from Dewetron
Current sensors, from shunts to clamps and flexible coils
Accelerometers, convenient IEPE
(constant current) types, with and without TEDS automatic sensor identification
Thermocouples, in several standard types and lengths
Speed and distance sensors, GPS based
Inertial sensors, from entry level to high-end
Video cameras, USB, firewire, and ethernet
74
Dewetron ProDUCt SeLeCtIon GUIDe
CUrrent sensors
Shunts
MODEL NAME
DAQ-SHUNT-1
fORM fACTOR
Plugs directly into the banana jacks of a DAQP-LV-B or similar module
DAQ-SHUNT-1-BNC
Plugs directly into the 9-pin DSUB jack of a DAQP-LV-D or similar module
DAQ-SHUNT-3
Small insulated box
INPuT
Banana jacks
BNC
30 cm cable and banana plugs
DAQ-SHUNT-4
Small insulated box Banana jacks
DAQ-SHUNT-5
Small insulated box Banana jacks
OuTPuT
Banana plugs
9-pin DSUB
30 cm cable and banana plugs
30 cm cable and banana plugs
Banana jacks
AC/DC Clamps
MODEL NAME
PNA-CLAMP-150-DC
DC RANgES AC RANgES OuTPuT TyPE
0.2 to 100 ADC and
0.5 to 1000A
0.4 to 150 AAC
0.5 to 1400 AAC
10 mV/A
1 mV/A
AC/DC
CLAMP-ACDC-2000
Ave or Peak value: 200.0 or 2000 A DC, (±1.3 % rdg.
±3 dgt.)
Ave or Peak value:
200.0 or 2000 A DC,
(±1.3 % rdg. ±3 dgt.)
Voltage: 1
V/f.s. or
Waveform
AC/DC
TyPE
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
Z
0.1 Ω
0.1 Ω
0.1 Ω
0.1 Ω
0.1 Ω
ACC.
0.1%
DRIfT
<±10ppm/K
0.1% <±10ppm/K
0.1% <±10ppm/K
0.1% <±10ppm/K
0.1% <±10ppm/K
CONN ACCuRACy/COM-
MENTS
Banana plugs
0.5 to 20A:1.5%
20 to 200A: 1.50%
100 to 800 A: 2.50%
800 to 1000 A: 4%
POwER
9VDC battery or external power
Banana jacks & cable
(dc or 45-65 Hz):
±1.3%rdg.±3dgt.
(10-45 & 65-1kHz):
±2.0%rdg.±7dgt
Built-in LCD meter
9VDC battery or external AC/
DC power
AC CLAMPS
MODEL NAME
PNA-CLAMP-5
AC RANgE(S)
5 A
INPuT
Jaws
OuTPuT
PNA connector, voltage output
TyPE
AC
Z ACC.
<=1%
DRIfT
PNA-CLAMP-10
10 A Jaws
PNA connector, voltage output
AC <=1%
PNA-CLAMP-20
20 / 200 A selectable Jaws
PNA connector, voltage output
AC <=1%
PNA-CLAMP-20-B
20 / 200 A selectable Jaws
Banana plugs and cable, voltage output
AC <=1%
PNA-CLAMP-1000
1000 A Jaws
PNA connector, current output
AC <=1%
Dewetron ProDUCt SeLeCtIon GUIDe
75
CUrrent sensors
FLEXIBLE Current sensors
MODEL NAME
PNA-A100-200-45
INPuT RANgES
200 / 2000 A selectable
PNA-A100-200-80
200 / 2000 A selectable
PNA-A100-300-45
300 / 3000 A selectable
PNA-A100-300-80
300 / 3000 A selectable
PNA-FLEX-300-45
300 / 3000 A selectable
PNA-FLEX-300-80
300 / 3000 A selectable
PNA-A100-1000-120
100 / 1000 A selectable
COIL LENgTh
45 cm
OuTPuT
Banana plugs and box with 9VDC battery
TyPE
AC
80 cm
45 cm
80 cm
Banana plugs and box with 9VDC battery
AC
Banana plugs and box with 9VDC battery or with
PNA connector
Banana plugs and box with 9VDC battery or with
PNA connector
AC
AC
45 cm
80 cm
PNA connector AC
PNA connector AC
Z ACC.
DRIfT
<=1 %
<=1 %
<=1 %
<=1 %
<=1 %
<=1 %
120 cm
Banana plugs and box with 9VDC battery or with
PNA connector
AC <=1 %
Automotive Current Sensors (for DAQP-LV-BNC module)
MODEL NAME
SHUNT-MINI-1MR
IMAgE VALuE
1 mΩ shunt
SHUNT-MINI-500MR
500 mΩ shunt
SHUNT-ATO-1MR
1 mΩ shunt
SHUNT-ATO-500MR
500 mΩ shunt
SHUNT-MAXI-0.2MR
0.2 mΩ shunt
SHUNT-MAXI-500MR
500 mΩ shunt
SHUNT-STRIP-0.2MR
100 / 100
SHUNT-STRIP-500MR
500 mΩ shunt
fuSE SLOT
MINI fuse
MINI fuse
ATO fuse
ATO fuse
MAXI fuse
MAXI fuse
STRIP fuse
STRIP fuse
OuTPuT
3 meter connection cable, BNC
MEASuRINg RANgE
76
Dewetron ProDUCt SeLeCtIon GUIDe
aCCelerometers
GENERAL PURPOSE, IEPE type (constant current)
MODEL NAME
SEN-ACC-3055B3T
RANgE OuTPuT CONNECTOR MOuNTINg TEDS ISOLATED wgT.
±10 G 500 mV/g
10-32 side connector
10-32 mounting hole
Yes Yes 8.6 g
SEN-ACC-3055B2T
±50 G 100 mV/g
10-32 side connector
10-32 mounting hole
Yes Yes 8.6 g
SEN-ACC-3055B1T
±500 G 10 mV/g
10-32 side connector
10-32 mounting hole
Yes Yes 8.6 g
SEN-ACC-3055B4
±100 G 50 mV/g
10-32 side connector
10-32 mounting hole
No No 10 g
SEN-ACC-3056B3T
±10 G 500 mV/g
10-32 top connector
10-32 mounting hole
Yes Yes 8.7 g
SEN-ACC-3056B2T
±50 G 100 mV/g
10-32 top connector
10-32 mounting hole
Yes Yes 8.7 g
SEN-ACC-3056B1T
±500 G 10 mV/g
10-32 top connector
10-32 mounting hole
Yes Yes 8.7 g
TRIAXIAL, IEPE type (constant current)
MODEL NAME
SEN-ACC-3023A
RANgE OuTPuT CONNECTOR MOuNTINg TEDS ISOLATED wgT.
±500 G 10 mV/g 1/4-28 4-pin Adhesive No (Case) 3 g
SEN-ACC-3023A3
±1000 G 5 mV/g 1/4-28 4-pin Adhesive No (Case) 3 g
SEN-ACC-3023A5
±5000 G 1 mV/g 1/4-28 4-pin Adhesive No (Case) 3 g
SEN-ACC-3023A1T
±500 G 10 mV/g 1/4-28 4-pin
5-40 mounting hole
Yes (Case)
Many other accelerometers and types are available - please call with your requirements. the above are only the most common.
6.2 g
DIMS.
0.50 x 0.62 in.
CABLE
CBL-6011A10
0.50 x 0.62 in.
CBL-6011A10
0.50 x 0.62 in.
CBL-6011A10
0.50 x 0.62 in.
CBL-6011A10
0.50 x 0.91 in.
CBL-6011A10
0.50 x 0.91 in.
CBL-6011A10
0.50 x 0.91 in.
CBL-6011A10
DIMS.
0.36
3
in.
0.36
3
in.
0.49 x 0.36 x
0.36 in.
0.45 x 0.45 x
0.48 in
CABLE
CBL-6811xx
CBL-6811xx
CBL-6811xx
CBL-6811xx
thermoCoUPles
MODEL NAME
SEN-TH-K-1
ThERMOCOuPLES
Type K thermocouple with 1 meter long cable, mini TC, bare hot side ends. Also available in longer lengths, and with probes on the hot side. Consult Dewetron.
SEN-TH-J-1
Type J thermocouple with 1 meter long cable, mini TC, bare hot side ends. Also available in longer lengths, and with probes on the hot side. Consult Dewetron.
SEN-TH-T-1
Type T thermocouple with 1 meter long cable, mini TC, bare hot side ends. Also available in longer lengths, and with probes on the hot side. Consult Dewetron.
thermocouples area available in countless lengths and configurations - please call with your requirements.
CABLE/CONNECTOR COMPATIBLE MODuLE(S)
Standard mini T/C connector, color coded
DAQP-MULTI
DAQP-THERM
DAQP-STG with MSI-BR-TH8-
J (or K or T)
EPAD2-TH8-J (or K or T)
DS-NET=TH8 ... and more!
Dewetron ProDUCt SeLeCtIon GUIDe
77
DEwETRON SPECIALTy SENSORS
sPeeD/DistanCe gPs sensors
DEWE-VGPS-200C
The classic DEWE-VGPS-200C has a top notch 20 Hz GPS inside, and 200 Hz derived speed and distance analog outputs for fifth wheel applications in dynamic vehicle testing. In addition, there are digital outputs for all signals, including speed, distance, number of satellites, UTC time, latitude, longitude, acceleration, and more. Connects to your DEWETRON system via RS232,
USB, or CAN BUS. The DEWE-VGPS-200C can also be used as a timing/synchronization reference for Dewetron systems.
DS-7 compatible.
DEWE-VGPS-HS
Built purely for speed and no frills, the DEWE-VGPS-HS has a powerful 100 Hz (non-interpolated) GPS inside. This is the perfect replacement for fifth wheels in dynamic vehicle testing.
There are digital outputs for all signals: speed, distance, number of satellites, UTC time, latitude, longitude, acceleration, and more. Connects to your DEWETRON system via USB.
DS-7 compatible.
BOTH OF THE VGPS SENSORS ABOVE INCLUDE:
9-36 VDC input power, cigaratte lighter plug and 2m power cable, magnetic antenna a 5 m cable, bright windshield display and 2 m cable
GPS-USB-1
If you don’t need the update rate of the VGPS units above, consider a simpler 1 Hz GPS sensor at a fraction of the cost.
Standard NMEA sensors with speed, latitude, longitude, and time are available as USB outputs.
enCoDers
We couldn’t find encoders that were reliable enough, so we made our own:
CA-ENCODER-3600
Incremental hollow shaft encoder with fixturing and 10m cable,
3600 pulses per revolution = 0.1° resolution, max. 5000 rpm, shaft Ø 12mm (end to end hollow shaft), IP65 protection
CA-ENCODER-900
Incremental hollow shaft encoder with fixturing and 10m cable,
900 pulses per revolution = 0.4° resolution, 0.1° resolution in combination with DEWE-xxxx-CA2-PROF or DEWE-
CRANkANGLE-CPU, max. 12000 rpm, shaft Ø 12mm (end to end hollow shaft), IP65 protection
CA-RIE-360
Rugged Industrial encoder, 360 pulses per revolution plus one zero-pulse, 0.1° resolution in combination with DEWE-xxxx-
CA2-PROF or DEWE-CRANkANGLE-CPU, max. 12.000 rpm, standard disc with 40 mm hole for shaft-mounting (custom versions available)
CA-RIE-720-SPEC
Rugged Industrial encoder, 720 pulses per revolution plus one zero-pulse, 0.1° resolution in combination with DEWE-xxxx-CA2-
PROF or DEWE-CRANkANGLE-CPU, max. 6000 rpm, customer defined shaft-mounting dimension for the disc
78
Dewetron ProDUCt SeLeCtIon GUIDe
CA-rIe encoder by Dewetron
CAMERA SENSORS
There are several cameras available for your Dewetron system, starting with the tightly synchronized DEWE-CAM-01, which offers frame rates as high as 240 fps (depending on image size), and connects via Firewire. If you need to record video far away, use the DEWE-CAM-GIG-E-50, which connects to your Dewetron system via low-cost ethernet cabling, 100 meters distant.
The least expensive type of camera is a DirectX webcam, available at any computer store and very inexpensive. These are ideal for adding visual documentation to your tests at the lowest possible cost.
Analog NTSC and PAL cameras can be used easily by adding the FG-VIDEO-4 PCI or PCIe card to your Dewetron system -- please see the previous section for more info on that four channel video interface card.
Infra-red cameras from FLIR can be interfaced with your Dewetron system very easily - see the next page for details.
Need to record HIGH SPEED video and then sync it to your Dewetron acquisition data? Our PHOTRON interface makes it easier and more automated than ever! See info on the next pages.
Dewe-Cam-01
Our best continuous acquistition camera, connects via IEEE-488 to most Dewetron systems. Capable of high speed continuous recording to disk in perfect sync with the data. Video adds a huge amount of context to your recorded data, and is a hallmark of
Dewetron’s data acquisition systems. Imagine what synchronized video could add to your important test data!
◙
◙
◙
◙
◙
◙
◙
◙
◙
◙
VGA 640 x 480 progressive CCD
Up to 70 fps @ full resolution
High quality color correction algorithm
Accepts C mount lenses
Auto-exposure, and wide gain control
Frames can be triggered from the Dewetron system, or free running (best speed is achieved via triggered mode)
Locking IEEE-488 (firewire) connector
Standard camera mount tapped holes and movable plate
Includes basic lens, cables, suction cup
Requires DS-7-PROF software level
Dewe-Cam-gig-e-50
Our latest continuous acquistition camera, connects via ethernet
(1 Gb) to most Dewetron systems. Capable of continuous recording to disk in sync with the data. Key benefit: ethernet cameras can be located far away from the acquisition system.
◙
◙
◙
◙
◙
◙
◙
Up to 55 fps at 780 x 580 px resolution
Up to 175 fps at 640 x 120 px resolution
Up to 100 m cable length (3 m standard)
Mounting plate and suction cup
6 mm lens included (accepts other lenses)
Sony CCD sensor for outstanding image quality
Requires DS-7-PROF software level
Dewetron ProDUCt SeLeCtIon GUIDe
79
infra-reD Cameras
If you are using FLIR Thermovision cameras listed below, you can connect them to your Dewetron system and record color or grayscale IR data in sync with your data. The software option called PLUGIN-FLIR adds support for data visualization, analysis and storage with the cameras listed below.
◙
◙
◙
◙
Supports FLIR models A300, A310, A315, A320, A325
Supports FLIR model A615
Supports FLIR models SC305, SC645, and SC655
Requires DS-7-7-PROF or higher plus PLUGIN-FLIR software option
Infra-red is a great way to see your data like never before. It is ideal for machine health monitoring. you can see many electrical problems from their heat signature long before they can be measured any other way.
In the automotive world, watch as brake pads heat up dynamically during braking tests, in a way that can never be instrumented with wired sensors.
FLIR is the preeminent maker of infra-red cameras, which is why we made this powerful software interface to some of their most popular and useful cameras used within the test and measurement realms.
A300 A310 A315 A615
320 x 240 pixel IR resolution
MPEG-4 streamed video
C-VIDEO
Most affordable model
SC305
320 x 240 pixel IR resolution
Extensive analysis functions
Built-in alarm functions
Ethernet/IP connectivity
Digital inputs/outputs
SC325
320 x 240 pixel IR resolution
16-bit image stream
GigE Vision™ standard compatibility
GenICam™ protocol support
Digital inputs/outputs
640 x 480 pixel IR resolution
16-bit image stream
GigE Vision™ standard compatibility
GenICam™ protocol support
Digital inputs/outputs
Windowing mode
SC645 SC655
320 x 240 pixel IR resolution
9 Hz frame rate
320 x 240 pixel IR resolution
60 Hz frame rate
640 x 480 pixel IR resolution
25 Hz frame rate
640 x 480 pixel IR resolution up to 200 Hz frame rate
GigE Vision™ standard compatibility
GenICam™ protocol support
GigE Vision™ standard compatibility
GenICam™ protocol support
GigE Vision™ standard compatibility
GenICam™ protocol support
GigE Vision™ standard compatibility
GenICam™ protocol support
QuickPlot & ExaminIR software compatible QuickPlot & ExaminIR software compatible QuickPlot & ExaminIR software compatible QuickPlot & ExaminIR software compatible
GigE and USB 2.0 HS GigE and USB 2.0 HS
Compartment for optical filter Compartment for optical filter
80
Dewetron ProDUCt SeLeCtIon GUIDe
high sPeeD viDeo Cameras
Photron high speed cameras listed below, Fastcam SA1 and
Fastcam 1024 PCI, allows video data acquisition of up to 100.000 fps, fully synchronized with analog data, triggering can be software, at start of the measurement or external.
◙
◙
◙
Supports Photron Fastcam SA1 camera
Supports Photron Fastcam 1024 PCI (card)
Requires DS-7-7-PROF plus PLUGIN-PHOTRON-HS-CAM software option
The FASTCAM SA1 improved provides blistering fast speed, unmatched light sensitivity and true 12-bit performance. Capable of over 5,000 full frames per second (fps) at mega pixel (1k x 1k) resolution, the brand new CMOS sensor provides true twelve bit pixel depth and is now capable of reduced resolution faster than
650,000 fps!.
Building on the experience gained with the EMMy® award winning ultima APX and ultima APX-RS cameras, the FASTCAM
SA1 is our most light sensitive camera yet, as well as providing the greatest color fidelity of any high speed camera available, thanks to true 12-bit performance. The FASTCAM SA1 provides the perfect tool for those looking for mega pixel resolution at high speeds, as well as those demanding sensitivity and performance with an SDI digital output for TV/movie and commercial work.
Available with three memory options:
• Eight (8) Gigabytes for ~6 seconds record duration at full
•
• resolution 1,000 fps
Sixteen (16) Gigabytes for >12 seconds record duration at full resolution @ 1,000 fps
Thirty two (32) Gigabytes for >24 seconds record duration at full resolution @ 1,000 fps
The FASTCAM SA1 is supplied with a RS422 LCD equipped keypad, making computer-free setup and operation easier than ever. Two rear panel BNC connectors provide users with both composite video (NTSC or PAL) as well as SDI (720i) outputs.
The FASTCAM 1024 PCI is the world’s first PC based mega pixel @ 1,000 fps camera is perfect for high speed PIV and DIC applications. Utilizing the same super sensitive CMOS sensor used in the Emmy award™ winning ultima APX and ultima APX-
RS cameras, the 1024 PCI offers true 10 bit images all the way to a top speed in excess of 100,000 fps.
The compact camera head is ideal for use in tricky to locate or hazardous locations and is supplied with both C and F-mount lens adapters. A single flexible cable sixteen feet (5 meters) long connects the camera head to the PCI card which resides in either a standard desktop PC or more portable PCI cradle connected to a laptop.
•
•
•
Several different memory options are available; all fitting snugly against the card to ensure never more than a single PCI slot is required per camera system. Current options include:
• Standard 2 Gigabyte (GB) for 1.54 second record time at
1,000 fps
Enhanced 6GB for 4.61 seconds at 1,000 fps
Expanded 12GB for 9.22 seconds at 1,000 fps
Maximum 24GB for 18.44 seconds at 1,000 fps
DireCtx viDeo Cameras
Just about DirectX camera, popularly known as “webcams,” can be used with your Dewetron system. DS-7-SE supports ONE camera, while DS-7-PROF supports multiple cameras.
◙
◙
◙
Low-speed (20 fps typical)
Average latency can be offset in software
Very inexpensive - and no software option required for one camera support
Dewetron ProDUCt SeLeCtIon GUIDe
81
aDma series gYro / gPs sensors
The ADMA (Automotive Dynamic Motion Analyzer) gyro system was developed especially for the dynamic testing of surface vehicles. Using the ADMA, all dynamic movements of a vehicle such as acceleration, speed, position, turning speed and angle of the vehicle can be displayed and recorded right on your
DEWETRON system.
◙
◙
◙
◙
◙
◙
Measurement of vehicle motion in three axes
Dynamic attitude (pitch & roll) and heading determination
Precise accel calculations via extended Kalman filter
Highly accurate position data with GPS receiver
Robust inertial strap-down system with no moving parts
Directly interfaces with DEWETRON systems
A 32-bit processor unit continuously calculates the angular orientation and position from internal sensor signals and external information (e.g. GPS or velocity sensors).
The package is implemented in strap-down-technology without moving parts and is therefore extremely robust and resistant to shock and vibration.
The calculation algorithms are optimized for dynamic vehicle tests such as slalom and circular movement. They take into account the gravitational acceleration and rotation of the earth.
To improve the accuracy of positional data and heading angle stability, an external speed signal (odometer or Correvit) or an external GPS system can be connected. Alternatively, the ADMA is also available with an internal GPS receiver (ADMA-G version).
CRITERIA
Accelerometers
Gyroscopes
GPS
Properties
Accessories included
DETAILS
Servo
MEMS
Closed loop FOG open loop FOG
MEMS
L1
L1 TRk20
L!/L2 RTk2
GLONASS omnistar
Vibration sensitivity
Bandwidth
Data latency
Initialization time
GPS sync
ADMA-ATC Aluminum transport case
ADMA-PTC Plastic transport case
ADMA-CBL-CAN CAN cable
ADMA-CBL-COM COM cable
ADMA-CBL-POWER Power cable
ADMA-CBL-PROG Programming cable
ADMA-GPS-5
GPS antenna cable (5 m)
ADMA-GPS-ANT-L1L2-702-GG
GPS Antenna L1/L2 702-GG
ADMA-MAG-BASE
Magnetic base for GPS Antenna
ADMA-GPS-ANT-L1
GPS Antenna L1 AT575 with cable and mag mount
COMMENT
1 mg accuracy
5 mg accuracy
0.1°/h in-run bias
1°/h in-run bias
5°/h in-run bias
The extended Kalman filter merges the internal with the external sensor data to achieve high frequency output as well as amazing accuracy. In this way, positional accuracy in the range of several cm’s can be measured while the vehicle is in motion.
Data output is transmitted via a CAN bus which is connected directly to your DEWETRON system, such as the DEWE-214,
DEWE-211, and DEWE-501. In addition to simple operation, synchronization with other measuring signals is ensured.
No yes yes yes yes
External
External
External
External
External no
50 ~ 400
< 2 ms
< 2 min.
Available
wITh EXTERNAL gPS
ADMA
√
√ yes
No
No
No
ADMA-ECO+
√
√
External
External
External
External
External no
50 ~ 400
< 2 ms
< 4 min.
Available yes
No yes yes yes yes
No
No
No
ADMA-g
√
√
No yes yes yes yes yes yes yes
Optional
Optional no
50 ~ 400
< 2 ms
< 2 min.
Available yes yes yes yes
wITh INTERNAL gPS
ADMA-g-ECO+ ADMA-g-ECO
√
√ yes
No yes yes yes yes yes yes yes
Optional
Optional no
50 ~ 400
< 2 ms
< 4 min.
Available yes yes yes
√
√
No yes yes yes yes yes yes yes
Optional
Optional no
50 ~ 400
< 2 ms
< 4 min.
Available yes yes yes yes
ADMA-g-EL+
√
ADMA-g-EL
< 6 min.
Available
For RTk2,
RTk20
For L1 yes yes yes yes
√ yes yes yes
Optional
Optional yes
50 ~ 100
< 2 ms
For RTk2,
RTk20
For RTk2,
RTk20
For RTk2,
RTk20
< 6 min.
Available
For RTk2,
RTk20
For L1 yes yes yes yes
√ yes yes yes
Optional
Optional yes
50 ~ 100
< 2 ms
For RTk2,
RTk20
For RTk2,
RTk20
For RTk2,
RTk20
√
No No No No No For L1 For L1
82
Dewetron ProDUCt SeLeCtIon GUIDe
◙
◙
◙
◙
aDma / aDma-g series aPPliCations
◙ Vehicle driving dynamics analysis
◙ Adjustment of chassis systems
Road holding test kinematic and elasto-kinematic analysis
Verification of simulation models
Deceleration/acceleration testing
Increased accuracy via BASE station
you can greatly enhance the accuracy of any GPS system via the addition of a BASE station. ADMA series sensors are compatible with the corrected / enhanced positional values that these bases broadcast.
In addition, a BASE STATION is available from DEWETRON.
This outdoor base station is designed for the easy-to-use generation of DGPS correction data for the mobile GPS receiver in or connected to the ADMA inertial system. It was developed especially for the dynamic testing of automobiles, but it is also heavily used to test all kinds of surface vehicles, including trucks, military tanks, and even trains.
The GPS outdoor base station is required to achieve highly accurate RTk 2 position data in the range of 2 cm. This is better than one inch accuracy.
◙
◙
◙
◙
◙
◙
Tire testing
Road surveys
Test track analysis
GIS data acquisition
Verification of driver assistance systems
Steering robot navigation
mti gYro / gPs sensors
XSENS-MTI & MTI-G
The MTI series are lower cost inertial sensors for basic dynamic applications. The MTI series are so small and lightweight that they can even be worn. They are often used for human motion capture and related applications, so you can believe their small size and weight.
Both versions provide 3-D orientation, calibrated 3D acceleration, the PLUGIN-XSENS for DS-7 software, and convenient USB 2.0 connection to your DEWETRON system.
XSENS-MTI-5
◙ Range ± 50 m/s
2
± 300 °/s
XSENS-MTI-5
◙
◙
Adds GPS correction to the MTI-5
Range ± 50 m/s
2
± 300 °/s
Dewetron ProDUCt SeLeCtIon GUIDe
83
CC series shipping cases
MoB-DISP-17 mobile display
DPS-2410 AC/DC charger
Dewetron Accessories
http://www.dewamerica.com/Products/Accessories
◙
◙
◙
◙
◙
◙
OVERVIEw
We offer a variety of useful and important accessories specifically for DEWETRON data acquisition systems. From mobile displays to shipping cases, carrying bags, and more, we’ve got perfectly fitted parts to help you get the most from your investment.
MOBILE displays for field and vehicle testing applications
BATTERy chargers and replacement batteries
Isolated POWER supplies, AC/DC and DC/DC
SHIPPING cases, rated for common carrier shipping
CARRy BAGS for putting a system on your shoulder and moving it around
VEHICLE testing specific items, like mounting poles
◙
◙
◙
◙
Made specifically for and tested with your DEWETRON system
Guaranteed 100% compatibility
Backed by the same full year warranty of your data acquisition system
Top notch performance
84
Dewetron ProDUCt SeLeCtIon GUIDe
moBile DisPlaYs
MODEL NAME
MOB-DISP-17
DESCRIPTION
17” diagonal display - high resolution 1280x1024 px
CAPACITIVE USB touchscreen interface - supports multi-touch applications
Built-in USB 2.0 ports for easy connection of keyboards and USB sticks
Includes AC/DC adapter
Runs natively from DC power
Includes VGA, USB and power cables
DISP-17-OPT
MOB-DISP-12A
OPTIONS
DISP-17-OPT (see next item)
Optional suction cups and 3 meter USB and VGA cable for automotive applications
Plus 1 m power cable with cigarette lighter plug on the input side
12.1” diagonal display, 1024x768 resolution
Includes suction cups, AC/DC adapter
Runs natively from DC power
Includes VGA and power cables
Optional RESISTIVE touchscreen interface
DISP-15-TOUCH touchscreen interface
Batteries anD Chargers
MODEL NAME
BATT-95WH
DESCRIPTION
◙
◙
◙
Compatible with the DEWE-3200, DEWE-3210, DEWE-3050, DEWE-2600*,
DEWE-501, DEWE-571, DEWE-571-PNA, DEWE2-A4*, DEWE-5000*, DA-120,
DA-121, DA-124, DEWE-211*, DEWE-1201*
◙ Smart LITHIUM ION “Smart battery”
Built-in LED display and push-button access to charge level
Capable of hundreds of charge/discharge cycles - lasts for years
95WH, 14.4VDC 8A nominal output
* battery power is optional in this model
NEUTRINO-4
BAT-CHARGER-1
BAT-BELTPACK
◙
◙
◙
◙
RUGGEDIZED four battery charger, which can also be used as a VDC source:
◙ Charges up to four BATT-95WH smart batteries simultaneously
Built-in LCD display of charge status
Powered from 120/240 VAC
◙ Can also be used as a DC power SOURCE in certain DC powered or battery powered DEWETRON systems
Rugged MIL-STD-810 construction
CE MARK, made in USA
◙
◙
Simple desktop charger for a single BATT-95WH
◙
Includes AC/DC adapter and power cord
LEDs indicate charging status
Plastic construction, suitable for office environment (not ruggedized)
◙
◙
Canvas beltpack and one BATT-95WH, for mobile applications
◙ Includes coiled power cord with connector for various DEWE systems
(please specify which DEWE system you wish to power)
Convenient belt-loops
Makes the ideal portable power source (18-24VDC) for DEWE-CAM-
GIG-E-50 cameras, DEWE-43, and more.
OPTIONS
N/A
N/A
IMAgE
IMAgE
Dewe-2600 with optional batteries Dewe-3210 with standard batteries Dewe-3050 with standard batteries
Dewetron ProDUCt SeLeCtIon GUIDe
85
Power sUPPlies
MODEL NAME
DPS-2410
DEWE-DCDC-24-300-ISO
DESCRIPTION
Specifically made for the DEWE-3210 series, the DPS-2410 provides a powerful
24 VDC at up to 10 amps, continuous. This is designed to allow your DEWE-3210 to be charging the batteries AND running the system at the same time. Includes AC power cable with standard US grounded instrument grade power cable (2m), and
DC-DC cable for connecting the DPS-2410 to the DEWE-3210 chassis, with keyed
LEMO connectors on each end.
Ideal for in-vehicle applications, solving two problems at once: if your DEWE system does not have a wide enough DC power input range; and to ISOLATE the power from the measuring instrument, to avoid ground loops and other measurement problems. The DEWE-DCDC-24-300-ISO is an external DC/DC converter with high isolation, 9 ~ 36 VDC input range, LEMO EGJ.3B.302, includes. 2 m cable to banana jacks, 24 VDC output, 300 W, LEMO EGG.2B.302 connector.
N/A
OPTIONS
If you have an older system with round black power jack, please request the proper mating cable
IMAgE
shiPPing Cases
If you need to ship your DEWETRON system from point A to point B, you probably want it to be working when it arrives. The rough handling and drops that happen during common carrier shipment is well known, and no matter how rugged we try to make our products, they cannot withstand an angry gorilla who wants to drop them
3 meters off a loading dock onto the cement. So protect your investment as best you can with one of our CC series common carrier rated shipping cases.
MODEL NAME
CC-3210
DESCRIPTION
◙
◙
Compatible with the DEWE-3200, DEWE-3210, and older models DA-120, DA-121
◙
Common carrier rated shipping case
Pull-out handle, and wheels
◙
Rated for international shipment
Custom cut foam interior with holes made specifically for this model
OPTIONS
N/A
IMAgE
CC-3040
Compatible with the DEWE-3050 and older DA-124 models N/A
CC-2600
Compatible with the DEWE-2600 N/A
CC-5000
Compatible with the DEWE-2600 N/A
* Almost every Dewetron model has a CC series shipping case. Please ask your Dewetron sales representative for details.
CarrY Bags
Most DEWETRON systems come with a carry bag. But after some years they can get worn out, or lost. They are made so well, and with the features that our customers like, that they get “repurposed” for other applications, and you need a replacement. Here is one example - and there are many more available:
MODEL NAME
3200-BAG
DESCRIPTION
◙
◙
Compatible with the DEWE-3200, DEWE-3210, and older models DA-120, DA-121
◙
Convenient shoulder bag for DEWE-3210/DA-120 series
Carry straps and shoulder straps
Heavy duty ballistic canvas construction
◙ Zippered end pouches for DPS-2410, cables, and accessories
OPTIONS
N/A
IMAgE
* Almost every Dewetron model has a carry bag available. Please ask your Dewetron sales representative for details.
86
Dewetron ProDUCt SeLeCtIon GUIDe
Dewetron Calibration
http://www.dewamerica.com/Support
OVERVIEw
DEWETRON offers NIST traceable calibration of all our products, right at our USA headquarters in Rhode Island. Our professional
CAL LAB is run by a seasoned professional with more than 10 years experience running major calibration services. We have developed detailed calibration procedures under the Fluke MET/
CAL system, which also tracks every item that we calibrate in a powerful database. The custom hardware and calibration procedures that we use are also available for purchase by our major customers who want to have the capability of performing their own calibration. Our system consists of a Fluke 5500 calibrator and Agilent / HP 3458A multimeter, plus a Dewetron
CAL-RACK-16 base for calibrating plug-in modules (DAQ, PAD,
HSI). Then there are special connector fixtures for calibrating
MDAQ amplifiers and A/D cards, which are done in situ. The whole thing is run under MET/CAL.
◙
◙
◙
◙
◙
◙
NIST and Z540 traceable
CALIBRATION of your DEWETRON systems
Comprehensive AS-FOUND and/or
AS-LEFT Met/CAL calibration reports always included
Professional calibration service
Capable of providing traceable calibration of all Dewetron products
Calibration equipment and MET/ cal procedures are available for purchase, for those customers who wish to perform automated calibration themselves
CAL-MANUAL also available for customers to perform their own manual calibration verification
Please contact our support team today if you are interested in having your Dewetron hardware calibrated, or if you would like a quote on calibration equipment.
Please call us today at: +1 401-284-3750 and ask for the CAL
LAB.
Dewetron ProDUCt SeLeCtIon GUIDe
87
D900 FASt Datalogger
D900 Datalogger
http://www.dewamerica.com/Products/Dataloggers
OVERVIEw
If you close your eyes and think about a datalogger, you probably see a cheap instrument that cannot be calibrated, and which has a very low sample rate. In other words, you think of bargain basement data acquisition hardware with a lousy interface and display, if any.
Well, open your eyes and take a look at the D900 data logger. A remarkable NETWORKABLE instrument with industry leading ISOLATED inputs and a human interface no more complicated than your mobile phone.
The D900 features 8 isolated input channels capable of handling voltage, current and temperature. And there are logic/pulse inputs and alarm outputs.
◙
◙
◙
◙
◙
◙
◙
◙
◙
High speed data logger with 8 channels
100 kS/s/ch sample rate when capturing to internal RAM
1 kS/s/ch max sample rate when capturing to USB stick
Lowest sample rate: 1/minute
Capture also to USB stick/flash media at lower rates
Includes PC software with remote control capability
PC software also allows conversion of data files to Excel and text formats
CE Mark, ISO9001
Full year warranty
88
Dewetron ProDUCt SeLeCtIon GUIDe
VOLTAGE
TEMPERATURE
HUMIDITY
TRIGGER InPUT
COUnTInG / RPM
LOGIC / PULSE
mUltiPle inPUt tYPes
±20 mV to ±500V on BNC connectors
Thermocouples (J, K, T, E, R, S, B, N, W) (M3 screw terminal)
0 to 100% (requires optional B-530 sensor)
1 Trigger input
4 channels (counting, RPM, inst. mode)
4 channels of pulse or logic inputs (selectable as a bank)
8 fast inPUt Channels
The inputs are simultaneously sampled with 16-bit A/D converters. You can set the sample rate anywhere from 1 S/minute/ch to 100 kS/s/ch
(10 µs interval) when capturing to the internal RAM. Or you can select to capture to a USB stick that you plug in, at rates from 1 S/minute/ch to 1 kS/s/ch (1 ms interval).
Most signals are input via the insulated BNC connectors, while the thermocouples are connected via the M3 screw terminal connectors.
Thermocouple cables diameters up to 0.32 can be used.
great gUi / DisPlaY
The D900 features a brilliant 5.7” diagonal color display that serves as the user interface. You can show your data in these formats:
◙
◙
◙
◙
Waveforms + digital values
Enlarged waveforms
Digital values + calculation results
X-y graph
Buttons to the right of the screen complete the GUI, which is no more complicated to operate than the average mobile phone.
You can run the display at high speeds if needed: up to 10 ms/ division. At the other extreme you can run the display as slowly as 24 hours/division!
The free running display allows you to monitor your data right on the screen, even when you’re not recording it. And because waveforms are displayed on each setup screen, you can even change your settings while viewing the data.
D900 data logger
high voltage CaPaBle
The wide 500 V range allows 240 VAC power supply voltage waveform measurements. Using voltage, current AND a logic input allows simultaneous measurement of a test article’s power supply voltage, current and sequential control of various points.
Dewetron ProDUCt SeLeCtIon GUIDe
89
D900 specifications
Main system
Analog input channels
External I/O channels
Sample rate (interval)
Time/division
Timer functions
trigger input
Trigger types
Trigger conditions
Trigger combinations
Trigger modes
Alarm function
Alarm functions
Alarm output
Pulse input
RPM mode
Count mode
Inst mode
General
Calculation functions
PC interface
Ethernet functions
USB functions
Internal memory
External memory
Display screens
Display hardware
Withstand voltage
Power supply
AC power input
DC power input
Battery power
Power consumption
Mechanical
Dimensions W x H x D
Weight
Operating environment
Vibration conditions
8
Trigger input (1 channel),
Logic input (4 channels) or Pulse input (4 channels)
Alarm output (4 channels)
1 S/m to 100 kS/s (10 µs)
10 ms/div to 24 hours/div
Date and time, daily cycle, hourly cycle
Start: Data capture starts on trigger
Stop: Data capture stops on trigger
Start: Off, Input signal level (analog, logic/pulse), External*
1
Input signal level: Level OR, Level AND, Edge OR, Edge AND
H (Rising), L (Falling), Window In*
2
, Window Out*
2
Rising, Falling, Window In*
2
, Window Out*
2
Number of channels: 4, Open collector output (5V, 10 kΩ pull-up resistance)
50 to 20 M RPM/F.S. (in steps of 1, 2, or 5)
50 to 20 M C/F.S. (in steps of 1, 2, or 5)
50 to 20 M C/F.S. (in steps of 1, 2, or 5)
Statistical calculations*
4
: Average, Peak, Maximum, Minimum, RMS
(2 calculations can be set simultaneously)
Ethernet (10BASE-T/100BASE-TX), USB (High Speed supported) provided as standard
Web server, FTP server, NTP client
USB drive mode (File transfer and deletion from internal RAM memory)
One million data points / Internal flash memory:Approx. 256 MB
USB memory slot (High speed supported) USB memory slot (High speed supported) USB memory slot (High speed supported)*
5
Waveforms + digital values, enlarged waveforms, digital values + calculation results, X-y
5.7” diagonal color LCD TFT display
Between each input channel and GND: 1000 V p-p for one minute, between input terminals: 1000 Vp-p for one minute
100 to 240 VAC, 50 to 60 Hz, external AC/DC adapter is included
8.5 to 24 VDC
Two batteries can be installed (optional)
42 VA (when operating and charging batery with AC power)
232 x 150 x 80 mm (approx)
1.1 kg (approx., excluding AC adapter and battery)
0 to 40°C, 5 to 85% R.H. (15 to 35°C when using batteries)
Equivalent to automobile parts Type 1 Category A classification
Input specifications
Input terminals Voltage: insulated BNC (8)
Temperature: M3 screw terminals (8)
A/D subsystem
Isolation
Input ranges, voltage
Thermocouple types
Humdity input
Input filter
Voltage accuracy*
8
16-bit ADCs (14-bit effective)
Simultaneous sampling all analog channels
500V
20, 50, 100, 200, 500 mV;
1, 2, 5, 10, 20, 50, 100, 200, 500 V F.S., 1-5 V F.S.
Thermocouples : k, J, E, T, R, S, B, N, W (WRe5-26)
0 to 100% (voltage 0 V to 1 V scaling conversion) with B-530 (option)
Off, Line, 5 Hz, 50 Hz, 500 Hz (selectable on each channel)
±0.25% of F.S.
Maximum permissible input voltage
Between input channel + and - terminals:
20 mV to 1 V: ±30 VDC; 2 V to 500 V : ±500 VDC
Between input channel terminals:
60 V peak-to-peak
Between input channel terminals and GND:
60 V peak-to-peak
90
Dewetron ProDUCt SeLeCtIon GUIDe
Withstand voltage:
Thermocouple accuracy*
8
Accuracy conditions:
Between input channel terminals and GND terminal:
1 minute at 1000 V peak-to-peak
Between input channel terminals:
1 minute at 1000 V peak-to-peak
Type:
R / S:
Meas range:
0°C ≤ TS ≤100°C
100°C < TS ≤300°C
R:300°C < TS ≤1600°C
S:300°C < TS ≤1760°C
Accuracy:
±7.0°C
±5.0°C
±(0.05% of rdg +3.0°C)
±(0.05% of rdg +3.0°C)
B: k:
400°C ≤ TS ≤600°C
600°C < TS ≤1820°C
-200°C ≤ TS ≤ -100°C
-100°C < TS ≤ 1370°C
±5.5°C
±(0.05% of rdg +3.0°C)
±(0.05% of rdg +3.0°C)
±(0.05% of rdg +2.0°C)
E:
T:
-200°C ≤ TS ≤ -100°C
-100°C < TS ≤ 800°C
-200°C ≤ TS ≤-100°C
-100°C < TS ≤400°C
±(0.05% of rdg +3.0°C)
±(0.05% of rdg +2.0°C)
±(0.1% of rdg +2.5°C) ±(0.1% of rdg +1.5°C)
J: -200°C ≤ TS ≤-100°C
-100°C < TS ≤ 100°C
100°C < TS ≤ 1100°C
0°C ≤ TS ≤ 1300°C
±3.7°C
±2.7°C
±(0.05% of rdg +2.0°C)
±(0.1% of rdg +2.0°C) N:
W: 0°C ≤ TS ≤ 2000°C ±(0.1% of rdg +2.5°C)
@ 23°C±5°C, after 30 minute warm-up time. Filter : Line
GND : connected
Control software specifications
OS compatibility Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions)
Software functions
Remote setup
Display information
Data capture
D900 control, real-time data capture, data conversion to Excel & text
Amplifier, data capture, trigger settings, alarm settings, and more
Analog waveforms, logic waveforms, pulse waveforms, digital values
Real-time data:
Binary: Sampling speed: 10 μs to 60 s
CSV: Sampling speed: 10 ms to 60 s
Data conversion
2-screen mode
Statistical display
Data between cursors, or all data
Simultaneous display of real-time data and recorded data (history)
Maximum, minimum, and average values
Options and accessories
Battery pack*6 B-517
Logic alarm cable
DC power input cable
Humidity sensor *9
Safety voltage probe
BNC to BNC cable k-type thermocouple for static surfaces
L-shaped k-type thermocouple for static surfaces
B-513, 2 meters
B-514, 2 meters
B-530, 3 meters
RIC-141, 1:1 input/output, 42 pF
RIC-112, 1.5 meters
BNC to banana plug cable RIC-113, 1.5 meters
BNC - alligator clip cable RIC-114, 1.5 meters
Rod-shaped k-type thermocouple
RIC-410, 1.1 meters
RIC-420, 1.1 meters
RIC-430, 1.1 meters
Notes:
*1 Logic alarm cable (B-513) is required.
*2 Cannot be set for logic input
*3 Maximum input frequency: 50 kHz, maximum number of counts: 15 M C
*4 In real time or when Between Cursors has been specified (during Replay)
*5 1 file = 2 Gbytes (depends on the USB memory stick used) *6 Please install two battery packs.
*7 Connections are made to both the BNC terminal and M3 screw terminal for the same channel.
*8 Thermocouple diameters T:0.32, others:0.65
*9 Operating temperature range: -25 to +80°C
winDows software inClUDeD
Three measurement screens are provided for real time data display, during acquisition:
• Y/T display • X-Y display • FFT display
Them after you’re done recording, the REPLAY screen has a great ZOOM feature so you can examine areas of interest in greater detail.
Easy setup
You can configure the most important parameters of the D900 using the Windows software, too. Functions like entering channels names are easier on the computer, of course, where you have a full size keyboard to work with.
More analysis capabilities
Need even more analytical horsepower? Why not use DS-7 software! If you buy an LT license, you can import text format data files from the D900 and perform a wide range of analytical functions:
◙
◙
◙
◙
◙
Formula math, including trigonometry, algebra, boolean, and arithmetic
Filtering - design your own IIR, FIR and FFT filters. Highpass, low-pass, band-pass, band-stop. Up to 10th order.
Bessell, Butterworth, Chebychev
Integration, double integration, differentiation, double integration, custom multi-sectional polynomials
Array math processing and display in 2D and 3D modes
Options available for power analysis, FRF, sine processing, sound level metering, order tracking...
◙
◙
◙
◙
◙
more software fUnCtions
The standard windows software provides these additional capabilities:
Direct to Excel - eliminates time-consuming file conversion
Search function - look for specific values within the data
CSV batch file conversion - process multiple files at once
Thumbnail display of captured files
Ability to open text formatted data files in DS-7-LT or higher software, for advanced analysis functions
more file transfer fUnCtions
The standard windows software provides these additional capabilities:
◙
◙
◙
Web server/FTP server - Waveform display and D900 setup operations can be performed via a web browser. In addition, data files captured to the D900’s internal memory or to a
USB memory stick can be transferred or deleted from PC.
USB mode - When your D900 is connected to your PC via the USB interface, you can perform fast and easy data transfers from the internal memory to the PC.
NTP client function - Connect the D900 to an NTP server via an Ethernet connection to synchronize D900 time with NTP server time at periodic intervals.
Dewetron ProDUCt SeLeCtIon GUIDe
91
DIREcT DEwE offIcES nEw EnGlAnD
SoUTHERn cAlIfoRnIA
DETRoIT
SoUTHEAST USA
SAlES PARTnERS
All ovER THE USA cAnADA mExIco colomBIA
BRAZIl coSTA RIcA cHIlE
Dewe-3050 with 17” reMoVABLe touchscreen, and up to 96 dynamic channels with up to 1 MS/s/ch continuous acquisition to disk
USA HEADQUARTERS
DEwETRon, Inc.
10 HIGH STREET, SUITE K wAKEfIElD, RI 02879
USA
PHonE +1 401-284-3750 fAx: +1 401-284-3755
www.DEwAmERIcA.com
Advertisement
Key features
- Highly configurable and economical
- Choice of signal conditioners
- Full power DEWE computer inside
- Compatible with ORION and AD series A/D cards
- Wide range DC power input
- Ruggedized Construction
- Small footprint D3PC available
- Made in USA
- Full year warranty