advertisement
VIDEOMAN i s a r e gistere d tr a de ma r k of E O S A u stra l ia P t y L t d
Designe d , imp o rte d an d distrib u te d b y V ideoman S y stems Co.
200308.01
-7.1
W i de S c r e en I n t e r c o m K i t K i t M on i t o r on l y
- 7.1M
Fix a weather hood
Write a name on the tag
Description of Door Station FUTURO-7.1C features
8
DO1 DO2
Fig.8
9
7 www.videoman.com.au
1. CCD Camera
2. White LEDs for night vision
3. Speaker
4. Name Plate
5. CALL Button
6. Microphone
7. Cable terminals to monitor
A (Audio), G(Ground), B(DC10V),
V(Video) to Monitor
DO1 & DO2 : Voltage-free Normally Open
Door open contact
WARNING! The following variable registers should be adjusted by qualified technicians
ONLY.
8. Speaker volume on the Door Station
9. Microphone sensitivity on the Door Station
Descriptions of Power supply FUTURO-7PS
16VDC 1.0A Power supply
( + ) : White Broken Line : + DC 16V
( – ) : Black wire : Ground
Fig.9
Descriptions of Multi Door Switcher FUTURO-7.1SW -Optional Extra
D1
D2
Door #1
B
V
X
A
G
Monitor
+
--
Door #2
A
G
B
V
X
A
G
B
V
X
Fig.10
Refer to Fig.13 on Page 6 or Fig.14 on Page7
Monitor terminal group
A, G, B, V : Connect to Monitor(s)
X : Reserved for special applications
Door #1 terminal group
A, G, B, V : Connect to Door Station #1
X : Reserved for special applications
Door #2 terminal group
A, G, B, V : Connect to Door Station #2
X : Reserved for special applications
D1 : Connect to CA on monitor(s)
D2 : Reserved for special applications
+,-: Reserved power terminal for specical applications.
Pag4
IMPOR T AN T !! Please r e a d p a ge 9 & 1 0 for cable r e quiremen t s BEFOR E r u nning cable s
S y stem connection w i th one came r a and one m o nitor
FUTURO-7.1M
D01
D02
1
2
3
4
5
6
7 CA
8
9
10
To Door Station
B
FUTURO-7.1C
Set to 75 Ω on the last monitor
To 240V AC Main
Power Supply
FUTURO-7PS
16V 1.0A
Electric Door Strike
To 240V AC Main
Power Supply for
Door Strike
Fig. 1 1
S y stem connection w i th one came r a and t w o m o nitors
Monitor #1
FUTURO-7.1M
5
6
7
8
1
2
3
4
9
10
Monitor #2
FUTURO-7.1M
1
2
3
4
5
6
7
8
CA
9
10
To 240V AC Main
To 240V AC Main
Power Supply
FUTURO-7PS
16V 1.0A
Power Supply
FUTURO-7PS
16V 1.0A
FUTURO-7.1C
D01
D02
B
Electric Door Strike
To 240V AC Main
Power Supply for
Door Strike
Fig.12
Page5
IMPOR T AN T !! Please r e a d p a ge 9 & 1 0 for cable r e quiremen t s BEFOR E r u nning cables ww w .videoman.com.a u
S y stem connection w i th t w o Door S t a t ions and t w o Monitors
Monitor #1
FUTURO-7.1M
7
8
9
10
1
2
3
4
5
6
CA
FUTURO-7.1SW
D01
D02
Door #1
FUTURO-7.1C
B
Electric Door Strike #1
Monitor #2
FUTURO-7.1M
7
8
9
10
1
2
3
4
5
6
CA
To 240V AC Main
Power Supply
FUTURO-7PS
16V 1.0A
Power Supply
FUTURO-7PS
16V 1.0A
To 240V AC Main
Power Supply for
Door Strike
Door #2
FUTURO-7.1C
D01
D02
B
Electric Door Strike #2
Fig.13
Page6
IMPOR T AN T !! Please r e a d p a ge 9 & 1 0 for cable r e quiremen t s BEFOR E r u nning cable s
S y stem connection w i th t w o Door S t a t ions and o n e Monitor
Monitor #1
FUTURO-7.1M
FUTURO-7.1SW
1
2
3
4
5
6
7
8
CA
Door #1
FUTURO-7.1C
D01
D02
Electric Door Strike #1
D01
D02
Door #2
FUTURO-7.1C
To 240V AC Main
Power Supply
FUTURO-7PS
16V 1.0A
Power Supply for
Door Strike
Electric Door Strike #2
Fig.14
V i deo distri b utor G L -D4 L -PLUS f o r multiple monitors
W hen more t h an t w o mo n i to r s are ins t al l ed i n a s y stem, it i s hig hl y r e co m men d ed to us e a video a m plif i e r GL - D4L-P L U S for better ima g e.
SE-12VDC05Adpt (Optional Extra)
75 Ω When GL-D4L-PLUS is used, the termination DIP switches shall set to
75ohm on all monitors.
G(Ground) wires from Door Station & Monitors
MUST connect to this GND terminals.
(+) (-)
Video IN
From V on Door Station
GL-D4L-PLUS (Optional Extra)
In order to employ the output (Out) of the video distributor,remove the jumper terminal( JP1 ) on the PCB
D 1 D 2 I n Ou t D 3 D4 to V on Monitor #4 to V on Monitor #3 to V on Monitor #2 to V on Monitor #1
Fig.15
Page7
www.videoman.com.au
ON
DOOR OPEN
1/2
Intercom
Call
Fig.16
Basic Operation
When a caller presses the call button on the outdoor station, a Ding-Dong sounds on the monitor and the video screen lights up for 30 seconds. If you are satisfied with the identity of the caller, press the “On” button to speak.
The screen will automatically turn off after 60 seconds.
To turn the screen back on, press the “On” button once, then you can see the visitors again and continue to talk with caller.
Monitoring doors through Monitor / Switching to Door#2
(This function is only available from master monitor)
Press the “On” button on monitor, the Audio and Video function will activate.
When system is connected with 2 door stations (Door#1, Door#2) the Door#1 will display by default.
“1/2” button allows you to switch from Door#1 to Door#2 by pressing and hold it.
To turn it off, press again or wait for 60 seconds.
Monitor adjustment
If desired, the ring volume and brightness may be adjusted.
Adjust volume at the right hand side of the monitor.
Door Strike operation
When electric door striker and additional power supply for it is in the system, it can be operated from monitor. While monitoring or talking, press “Open Door” button to open the electric door striker. When more than one door stations are in a system, it opens a door striker which is being monitored.
Operation for Intercommunication / Baby Monitoring between Monitors
When system is connected with multiple monitors, internal intercommunication and Audio Baby Monitoring is available between monitors.
An Intercom calling can be started by any indoor monitor. Press the “Intercom” button, this will ring all other monitors in a system and activate Audio communications between monitors without any further action.
The audio channel will remain active until pressing “Intercom” button again to turn off the function. During
Internal Communication/Audio Baby Monitoring, Intercom LED on monitors will light in Purple.
Page8
Cable requirement - STAR Wiring method
Junction room
Power Supply for door latch
Power Supply
FUTURO-7PS
Fig.18
An additional power supply and
Fig8 Cable is required for door strike operation (Indicated as broken lines on the diagrams)
FUTURO-7.1C
CAMERA
Fig8
4core
Screened
Fig8
Fig8
4core
Screened
Junction room
FUTURO-7.1M
MONITOR
Power Supply for door latch
Power Supply
FUTURO-7PS
Fig.19
FUTURO-7.1C
CAMERA
Fig8
4core
Screened
Fig8
5core
Screened Fig8
5core
Screened
Fig8
FUTURO-7.1M
MONITOR
FUTURO-7.1 M
MONITOR
Power Supply for door latch
Junction room
Multi Camera Switcher
FUTURO-7.1SW
Power Supply
FUTURO-7PS
Fig.20
Cable requirement
Based on the distance from a camera to the furthest monitor,
< 20M : CAT5 cable
Orange
W/Orange
A (Audio)
G (GND)
Green
W/Green
V (Video)
G (GND)
Blue
W/Blue
Brown
W/Brown
B (12VDC)
B (12VDC)
double up
DO 1
DO 2
(door open)
CAT5 wire configuration
< 50M :
14/020 (0.44mm 2 ) shielded cable
(connect shield to G)
AND
RG-59/U for video signal
(connect core to V & shield to G)
FUTURO-7.1C
CAMERA
Fig8
Fig8
Fig8
Fig8
4core
Screened
Fail-Secure
Door Strike
Fig8
6core
Screened
FUTURO-7.1M
MONITOR
NOTE
2 )
Junction room : Electrical switch room, junction room
or ceiling where all wires are joined.
Fig8
6core
Screened
FUTURO-7.1M
MONITOR
< 100M :
24/020 (0.44mm 2 ) shielded cable
(connect shield to G)
AND
RG-59/U for video signal
(connect core to V & shield to G)
> 100M :Contact your supplier
Page9
Cable requirement - Daisy Chain (loop-in-loop-out) wiring method www.videoman.com.au
Junction room
Fig.21
Power Supply for door latch
Power Supply
FUTURO-7PS MEMO
Fig8
FUTURO-7.1C
CAMERA
4core
Fig8
Fail-Secure
Door Strike
Power Supply for door latch
Fig8 4core
FUTURO-7.1M
MONITOR
Junction room
Power Supply
FUTURO-7PS
Fig.22
Fig8
FUTURO-7.1C
CAMERA
Fig8
4core
Screened
Fig8 Fig8
5core
Screened
FUTURO-7.1M
MONITOR
FUTURO-7.1M
MONITOR
FUTURO-7.1C
CAMERA
Fig8
Fig8
4core
Screened
Fail-Secure
Door Strike
Fig8
Power Supply for door latch
Junction room
Multi Camera Switcher
FUTURO-7.1SW
Power Supply
FUTURO-7PS
5core
Screened
Fig8
6core
Fig8
Screened
Fig8
5core
Screened
FUTURO-7.1M
MONITOR
Fig.23
FUTURO-7.1M
MONITOR
Fail-Secure
Door Strike
NOTE :
2 )
Junction room : electrical switch room, junction room, ceiling
Page10
MAINTENANCE
1. All components should be protected from violent vibration, impacting, knocking and dropping.
2. If necessary, clean the lens and screen with dampen so ft cotton cloth do not use chemical cleaning agent.
3. Image distortion may occur if the monitor is installed near mi crowave ovens, TVs, computers, DC/AC adaptors or any other ele ctro magnetic field generating appliances.
4. Keep all monitors and cameras away from hi gh temperature, dust, caustic and oxidation gas.
5. Use only with the FUTURO-7PS power supply whic h is supplied by the authorised VIDEOMAN supplier.
6. Pay attention to the high voltage inside the products. Please ensure this unit is only serviced by qualified professionals.
TECHNICAL SPECIFICATIONS
1. Talk auto-off time: 60 seconds
2. Surveillance auto-o ff time: 30 seconds
3. Power supply for indoor monitor : 16V DC 1.0Amp
4. Power for Door Station: 10V DC (Supplied by indoor monitor)
5. Power consumption: Standby 2W, Max. 14W
6. Monitor screen: 7” Colour TFT LCD, 1024(H) x 234(V)
7. Camera Lens: 3.6mm, 51 degree horizontal 41 degree vertical visual angle
8. Image sensor : 1/4” CCD, 270k Pixels
9. Resolution: >380 TV lines
10. Video signal: 1Vp-p, 75 Ω , CCIR standard
11. Connection mode: 4 wire, polarity conscious
12. Door strike operation : Voltage-fr ee Relay output from the Door Station
13. Door strike operation time : controlled by Door open button on Monitor
14. S/N Ratio : Video 50dB, Audio 40dB
WARRANTY STATEMENT
This equipment is warranted to be free from defects in material and workmanship for a period of tw elve months from the date of purchase as indicated on the proof of purchase and/or by serial number on the product.
Defective units returned by the purchaser at his own expense du ring this period will be repaired (or replaced at the option of the distributor) with an equivalent piece of refurbished and tested equipment. The repaired or replaced equipment is then warrant ed for the balance of the initial warranty period or for thirty (30) days, whichever is longer.
The repair or replacement will be without charge provided that the equipment has not been subjected to electrical of physical m isuse or to unauthorised repair or modification.
The foregoing warranty is in lieu of all other warranties, expr ess or implied, including, but not limited to, merchantability o r fitness for a particular purpose.
The purchaser's exclusive remedy with res pect to any and all losses or damages result ing from any cause whatsoever, shall be re pair or replacement as specified above.
Distributor shall in no event be liable for any consequential or incidental damages, however occasioned, whether by negligence or otherwise. No suit or action shall be brought against manufacturer more than one year afte r the accrual of the cause of action therefore. No agent, e mployee or representative of the distributor nor any other person is authorised to modify this warranty in any respect. Th is warranty gives you specific legal rights and you may also have other rights which vary from state to state. www.videoman.com.au
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement