VIDEOMAN Futuro 7.1 M User manual


Add to my manuals
12 Pages

advertisement

VIDEOMAN Futuro 7.1 M User manual | Manualzz

VIDEOMAN i s a r e gistere d tr a de ma r k of E O S A u stra l ia P t y L t d

Designe d , imp o rte d an d distrib u te d b y V ideoman S y stems Co.

200308.01

-7.1

W i de S c r e en I n t e r c o m K i t K i t M on i t o r on l y

- 7.1M

Fix a weather hood

Write a name on the tag

Description of Door Station FUTURO-7.1C features

8

DO1 DO2

Fig.8

9

7 www.videoman.com.au

1. CCD Camera

2. White LEDs for night vision

3. Speaker

4. Name Plate

5. CALL Button

6. Microphone

7. Cable terminals to monitor

A (Audio), G(Ground), B(DC10V),

V(Video) to Monitor

DO1 & DO2 : Voltage-free Normally Open

Door open contact

WARNING! The following variable registers should be adjusted by qualified technicians

ONLY.

8. Speaker volume on the Door Station

9. Microphone sensitivity on the Door Station

Descriptions of Power supply FUTURO-7PS

16VDC 1.0A Power supply

( + ) : White Broken Line : + DC 16V

( – ) : Black wire : Ground

Fig.9

Descriptions of Multi Door Switcher FUTURO-7.1SW -Optional Extra

D1

D2

Door #1

B

V

X

A

G

Monitor

+

--

Door #2

A

G

B

V

X

A

G

B

V

X

Fig.10

Refer to Fig.13 on Page 6 or Fig.14 on Page7

Monitor terminal group

A, G, B, V : Connect to Monitor(s)

X : Reserved for special applications

Door #1 terminal group

A, G, B, V : Connect to Door Station #1

X : Reserved for special applications

Door #2 terminal group

A, G, B, V : Connect to Door Station #2

X : Reserved for special applications

D1 : Connect to CA on monitor(s)

D2 : Reserved for special applications

+,-: Reserved power terminal for specical applications.

Pag4

IMPOR T AN T !! Please r e a d p a ge 9 & 1 0 for cable r e quiremen t s BEFOR E r u nning cable s

S y stem connection w i th one came r a and one m o nitor

FUTURO-7.1M

D01

D02

1

2

3

4

5

6

7 CA

8

9

10

To Door Station

B

FUTURO-7.1C

Set to 75 Ω on the last monitor

To 240V AC Main

Power Supply

FUTURO-7PS

16V 1.0A

Electric Door Strike

To 240V AC Main

Power Supply for

Door Strike

Fig. 1 1

S y stem connection w i th one came r a and t w o m o nitors

Monitor #1

FUTURO-7.1M

5

6

7

8

1

2

3

4

9

10

Monitor #2

FUTURO-7.1M

1

2

3

4

5

6

7

8

CA

9

10

To 240V AC Main

To 240V AC Main

Power Supply

FUTURO-7PS

16V 1.0A

Power Supply

FUTURO-7PS

16V 1.0A

FUTURO-7.1C

D01

D02

B

Electric Door Strike

To 240V AC Main

Power Supply for

Door Strike

Fig.12

Page5

IMPOR T AN T !! Please r e a d p a ge 9 & 1 0 for cable r e quiremen t s BEFOR E r u nning cables ww w .videoman.com.a u

S y stem connection w i th t w o Door S t a t ions and t w o Monitors

Monitor #1

FUTURO-7.1M

7

8

9

10

1

2

3

4

5

6

CA

FUTURO-7.1SW

D01

D02

Door #1

FUTURO-7.1C

B

Electric Door Strike #1

Monitor #2

FUTURO-7.1M

7

8

9

10

1

2

3

4

5

6

CA

To 240V AC Main

Power Supply

FUTURO-7PS

16V 1.0A

Power Supply

FUTURO-7PS

16V 1.0A

To 240V AC Main

Power Supply for

Door Strike

Door #2

FUTURO-7.1C

D01

D02

B

Electric Door Strike #2

Fig.13

Page6

IMPOR T AN T !! Please r e a d p a ge 9 & 1 0 for cable r e quiremen t s BEFOR E r u nning cable s

S y stem connection w i th t w o Door S t a t ions and o n e Monitor

Monitor #1

FUTURO-7.1M

FUTURO-7.1SW

1

2

3

4

5

6

7

8

CA

Door #1

FUTURO-7.1C

D01

D02

Electric Door Strike #1

D01

D02

Door #2

FUTURO-7.1C

To 240V AC Main

Power Supply

FUTURO-7PS

16V 1.0A

Power Supply for

Door Strike

Electric Door Strike #2

Fig.14

V i deo distri b utor G L -D4 L -PLUS f o r multiple monitors

W hen more t h an t w o mo n i to r s are ins t al l ed i n a s y stem, it i s hig hl y r e co m men d ed to us e a video a m plif i e r GL - D4L-P L U S for better ima g e.

SE-12VDC05Adpt (Optional Extra)

75 Ω When GL-D4L-PLUS is used, the termination DIP switches shall set to

75ohm on all monitors.

G(Ground) wires from Door Station & Monitors

MUST connect to this GND terminals.

(+) (-)

Video IN

From V on Door Station

GL-D4L-PLUS (Optional Extra)

In order to employ the output (Out) of the video distributor,remove the jumper terminal( JP1 ) on the PCB

D 1 D 2 I n Ou t D 3 D4 to V on Monitor #4 to V on Monitor #3 to V on Monitor #2 to V on Monitor #1

Fig.15

Page7

www.videoman.com.au

ON

DOOR OPEN

1/2

Intercom

Call

Fig.16

Basic Operation

When a caller presses the call button on the outdoor station, a Ding-Dong sounds on the monitor and the video screen lights up for 30 seconds. If you are satisfied with the identity of the caller, press the “On” button to speak.

The screen will automatically turn off after 60 seconds.

To turn the screen back on, press the “On” button once, then you can see the visitors again and continue to talk with caller.

Monitoring doors through Monitor / Switching to Door#2

(This function is only available from master monitor)

Press the “On” button on monitor, the Audio and Video function will activate.

When system is connected with 2 door stations (Door#1, Door#2) the Door#1 will display by default.

“1/2” button allows you to switch from Door#1 to Door#2 by pressing and hold it.

To turn it off, press again or wait for 60 seconds.

Monitor adjustment

If desired, the ring volume and brightness may be adjusted.

Adjust volume at the right hand side of the monitor.

Door Strike operation

When electric door striker and additional power supply for it is in the system, it can be operated from monitor. While monitoring or talking, press “Open Door” button to open the electric door striker. When more than one door stations are in a system, it opens a door striker which is being monitored.

Operation for Intercommunication / Baby Monitoring between Monitors

When system is connected with multiple monitors, internal intercommunication and Audio Baby Monitoring is available between monitors.

An Intercom calling can be started by any indoor monitor. Press the “Intercom” button, this will ring all other monitors in a system and activate Audio communications between monitors without any further action.

The audio channel will remain active until pressing “Intercom” button again to turn off the function. During

Internal Communication/Audio Baby Monitoring, Intercom LED on monitors will light in Purple.

Page8

Cable requirement - STAR Wiring method

Junction room

Power Supply for door latch

Power Supply

FUTURO-7PS

Fig.18

An additional power supply and

Fig8 Cable is required for door strike operation (Indicated as broken lines on the diagrams)

FUTURO-7.1C

CAMERA

Fig8

4core

Screened

Fig8

Fig8

4core

Screened

Junction room

FUTURO-7.1M

MONITOR

Power Supply for door latch

Power Supply

FUTURO-7PS

Fig.19

FUTURO-7.1C

CAMERA

Fig8

4core

Screened

Fig8

5core

Screened Fig8

5core

Screened

Fig8

FUTURO-7.1M

MONITOR

FUTURO-7.1 M

MONITOR

Power Supply for door latch

Junction room

Multi Camera Switcher

FUTURO-7.1SW

Power Supply

FUTURO-7PS

Fig.20

Cable requirement

Based on the distance from a camera to the furthest monitor,

< 20M : CAT5 cable

Orange

W/Orange

A (Audio)

G (GND)

Green

W/Green

V (Video)

G (GND)

Blue

W/Blue

Brown

W/Brown

B (12VDC)

B (12VDC)

double up

DO 1

DO 2

(door open)

CAT5 wire configuration

< 50M :

14/020 (0.44mm 2 ) shielded cable

(connect shield to G)

AND

RG-59/U for video signal

(connect core to V & shield to G)

FUTURO-7.1C

CAMERA

Fig8

Fig8

Fig8

Fig8

4core

Screened

Fail-Secure

Door Strike

Fig8

6core

Screened

FUTURO-7.1M

MONITOR

NOTE

2 )

Junction room : Electrical switch room, junction room

or ceiling where all wires are joined.

Fig8

6core

Screened

FUTURO-7.1M

MONITOR

< 100M :

24/020 (0.44mm 2 ) shielded cable

(connect shield to G)

AND

RG-59/U for video signal

(connect core to V & shield to G)

> 100M :Contact your supplier

Page9

Cable requirement - Daisy Chain (loop-in-loop-out) wiring method www.videoman.com.au

Junction room

Fig.21

Power Supply for door latch

Power Supply

FUTURO-7PS MEMO

Fig8

FUTURO-7.1C

CAMERA

4core

Fig8

Fail-Secure

Door Strike

Power Supply for door latch

Fig8 4core

FUTURO-7.1M

MONITOR

Junction room

Power Supply

FUTURO-7PS

Fig.22

Fig8

FUTURO-7.1C

CAMERA

Fig8

4core

Screened

Fig8 Fig8

5core

Screened

FUTURO-7.1M

MONITOR

FUTURO-7.1M

MONITOR

FUTURO-7.1C

CAMERA

Fig8

Fig8

4core

Screened

Fail-Secure

Door Strike

Fig8

Power Supply for door latch

Junction room

Multi Camera Switcher

FUTURO-7.1SW

Power Supply

FUTURO-7PS

5core

Screened

Fig8

6core

Fig8

Screened

Fig8

5core

Screened

FUTURO-7.1M

MONITOR

Fig.23

FUTURO-7.1M

MONITOR

Fail-Secure

Door Strike

NOTE :

2 )

Junction room : electrical switch room, junction room, ceiling

Page10

MAINTENANCE

1. All components should be protected from violent vibration, impacting, knocking and dropping.

2. If necessary, clean the lens and screen with dampen so ft cotton cloth do not use chemical cleaning agent.

3. Image distortion may occur if the monitor is installed near mi crowave ovens, TVs, computers, DC/AC adaptors or any other ele ctro magnetic field generating appliances.

4. Keep all monitors and cameras away from hi gh temperature, dust, caustic and oxidation gas.

5. Use only with the FUTURO-7PS power supply whic h is supplied by the authorised VIDEOMAN supplier.

6. Pay attention to the high voltage inside the products. Please ensure this unit is only serviced by qualified professionals.

TECHNICAL SPECIFICATIONS

1. Talk auto-off time: 60 seconds

2. Surveillance auto-o ff time: 30 seconds

3. Power supply for indoor monitor : 16V DC 1.0Amp

4. Power for Door Station: 10V DC (Supplied by indoor monitor)

5. Power consumption: Standby 2W, Max. 14W

6. Monitor screen: 7” Colour TFT LCD, 1024(H) x 234(V)

7. Camera Lens: 3.6mm, 51 degree horizontal 41 degree vertical visual angle

8. Image sensor : 1/4” CCD, 270k Pixels

9. Resolution: >380 TV lines

10. Video signal: 1Vp-p, 75 Ω , CCIR standard

11. Connection mode: 4 wire, polarity conscious

12. Door strike operation : Voltage-fr ee Relay output from the Door Station

13. Door strike operation time : controlled by Door open button on Monitor

14. S/N Ratio : Video 50dB, Audio 40dB

WARRANTY STATEMENT

This equipment is warranted to be free from defects in material and workmanship for a period of tw elve months from the date of purchase as indicated on the proof of purchase and/or by serial number on the product.

Defective units returned by the purchaser at his own expense du ring this period will be repaired (or replaced at the option of the distributor) with an equivalent piece of refurbished and tested equipment. The repaired or replaced equipment is then warrant ed for the balance of the initial warranty period or for thirty (30) days, whichever is longer.

The repair or replacement will be without charge provided that the equipment has not been subjected to electrical of physical m isuse or to unauthorised repair or modification.

The foregoing warranty is in lieu of all other warranties, expr ess or implied, including, but not limited to, merchantability o r fitness for a particular purpose.

The purchaser's exclusive remedy with res pect to any and all losses or damages result ing from any cause whatsoever, shall be re pair or replacement as specified above.

Distributor shall in no event be liable for any consequential or incidental damages, however occasioned, whether by negligence or otherwise. No suit or action shall be brought against manufacturer more than one year afte r the accrual of the cause of action therefore. No agent, e mployee or representative of the distributor nor any other person is authorised to modify this warranty in any respect. Th is warranty gives you specific legal rights and you may also have other rights which vary from state to state. www.videoman.com.au

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement