NIR-100
SPECIFICATIONS
Light source
Operating range
Response time
Relay output configuration
Relay contact rating
Power indicator
Obstruction indicator
Supply Voltage
Operating current
Dimensions
Weight
Housing
Connection
Mechanical protection
NIR
Up to 33ft.
10mS
Form C (SPDT)
1A @ 24VDC…120VAC
Green LED
Flashing Green led
12…24 VDC/VAC
60mA
2.0”(51mm) x 2.4”(61mm) x
1.0”(25mm)
0.21 lbs. (95 g)
ABS (plastic)
40” (1m) cable
NEMA4X
THRU–BEAM
PHOTOEYE
CAUTIONS AND WARNINGS
OPERATING INSTRUCTIONS
CAUTION:
MATERIALS SUPPLIED




Operating Instructions
NIR-100-RX
NIR-100-TX
130-10221062 Mounting bracket kit
GENERAL DESCRIPTION
The NIR-100 is a thru-beam photo eye that can be used as a
presence sensor in a wide variety of applications such as a
reversing sensor for commercial gates, overhead doors and
parking barriers. Unlike retro-reflective types of photo eyes
that can provide false indication when encountering highly
reflective surfaces on a vehicle, the NIR-100 provides the
highly reliable operation associated with a thru-beam
configuration. The relay is operated in fail-safe mode (deactivates during beam obstruction or any error condition).
A green alignment indicator on the receiver provides status
information at a glance, making set-up and alignment easy.
The NIR-100 operates over a wide range of 12-24VDC/VAC
and provides a fail-safe set of relay contacts for external
connection. A 40” (1m) cable is provided for connection to
site wiring.
OPERATION
4564 Johnston Parkway
Cleveland, Ohio 44128
United States of America
WEB http://www.emxinc.com
Technical Support Telephone (216) 834-0761
E-mail [email protected]
Sales Telephone (216) 518-9888
Fax: (216) 518-9884
E-mail [email protected]
NIR-100 Operating Instructions
Document no. 10220204 REV1.4
3.19.14
Green status indicator:
NIR-100-TX
NIR-100-RX
ON
Flashing
NIR-100-RX
ON
Power
Blocked beam
or not aligned
Aligned
INSTALLATION
Disconnect power from the operator before connecting the
photo eyes. See wiring information below for connections.
Mount the transmitter on one set of brackets and the receiver
on the other set. Position at 6” off of the floor on opposite
ends of the door or gate.
Align at up to 33’ transmitter to receiver distance.
WIRING
BROWN
WHITE
GREEN
RELAY NORMALLY OPEN CONTACT
RELAY NORMALLY CLOSED CONTACT
RELAY COMMON CONTACT
Relay contacts shown in with power applied and the receiver
aligned with the transmitter, beam unblocked.
CLEANING
Isopropyl alcohol with a soft cloth may be used to clean the
optics area.