INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81791
PAGE: 1 OF 7
ISSUE DATE: 06/10/14
PREPARED FOR: RAB LIGHTING, INC.
CATALOG NUMBER: HSLED18 (SPOT)
LUMINAIRE: CAST METAL HOUSING, BROWN PAINTED FLAT METAL HEAT SINK MOUNTING PLATE,
CAST BROWN PAINTED FINNED METAL HEAT SINK, 1 CIRCUIT BOARD WITH 1 LED, MOLDED
PLASTIC REFLECTOR WITH SPECULAR FINISH, CLEAR FLAT GLASS LENS IN CAST BROWN
PAINTED METAL FRAME.
LAMP: ONE WHITE MULTI-CHIP LIGHT EMITTING DIODE (LED), AIMED AT THE HORIZON.
TOTAL INPUT WATTS = 19.8 AT 120.0 VOLTS
LED DRIVER: RAB LIGHTING RD12-36-A0500
NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC,
60Hz) TO THE DRIVER.
TEST PROCEDURE: IESNA LM-79-08
TEST DISTANCE = 20.0 FEET
FLOODLIGHT CHARACTERISTICS
IES TYPE
3H X 3V
MAXIMUM CANDLEPOWER
11011. AT
0.0 H,
HORIZONTAL BEAM ANGLE (50%)
23.2 deg
VERTICAL BEAM ANGLE (50%)
23.1 deg
HORIZONTAL FIELD ANGLE (10%)
43.6 deg
VERTICAL FIELD ANGLE (10%)
43.6 deg
BEAM LUMENS (% FIXTURE)
1103. ( 55.2
FIELD LUMENS (% FIXTURE)
1814. ( 90.8
TOTAL LUMENS (% FIXTURE)
1997. (100.0
EFFICACY = 100.9 lm/W
3 7/8
5 1/2
Checked
M KLOPF
Approved
R BEATTIE
Lighting Engineer
0.0 V
% )
% )
% )
AXIAL CANDLEPOWER
DEG
HORIZ.
DEG
VERT.
90.0
85.0
75.0
65.0
55.0
47.5
42.5
37.5
33.0
29.0
25.5
22.5
19.5
17.0
15.0
13.0
11.0
9.0
7.0
5.0
3.0
1.0
0.0
-1.0
-3.0
-5.0
-7.0
-9.0
-11.0
-13.0
-15.0
-17.0
-19.5
-22.5
-25.5
-29.0
-33.0
-37.5
-42.5
-47.5
-55.0
-65.0
-75.0
-85.0
-90.0
0.
0.
1.
1.
1.
2.
3.
4.
7.
73.
443.
970.
1517.
1963.
2743.
3980.
6151.
8145.
9450.
10176.
10718.
10985.
11011.
10985.
10718.
10176.
9450.
8145.
6151.
3980.
2743.
1963.
1517.
970.
443.
73.
7.
4.
3.
2.
1.
1.
1.
0.
0.
90.0
85.0
75.0
65.0
55.0
47.5
42.5
37.5
33.0
29.0
25.5
22.5
19.5
17.0
15.0
13.0
11.0
9.0
7.0
5.0
3.0
1.0
0.0
-1.0
-3.0
-5.0
-7.0
-9.0
-11.0
-13.0
-15.0
-17.0
-19.5
-22.5
-25.5
-29.0
-33.0
-37.5
-42.5
-47.5
-55.0
-65.0
-75.0
-85.0
-90.0
0.
0.
0.
1.
1.
2.
3.
4.
9.
79.
410.
892.
1444.
1885.
2533.
3690.
5736.
8019.
9420.
10357.
10848.
11006.
11011.
10989.
10872.
10481.
9647.
8453.
6537.
4107.
2848.
2077.
1568.
1055.
487.
107.
7.
4.
2.
2.
1.
1.
1.
0.
0.
ALL CANDELA AND LUMEN VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81791
ISSUE DATE: 06/10/14
PREPARED FOR: RAB LIGHTING, INC.
PAGE: 2 OF 7
CANDELA TABULATION
AVERAGE OF RIGHT AND LEFT SIDES
0.0
1.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.5
22.5
25.5
29.0
33.0
37.5
42.5
47.5
55.0
65.0
75.0
85.0
90.0
90.0
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
85.0
0.
0.
0.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
75.0
0.
0.
0.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
65.0
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
0.
0.
0.
0.
55.0
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
2.
2.
2.
2.
2.
1.
1.
1.
1.
1.
0.
0.
0.
47.5
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
1.
1.
1.
1.
1.
0.
0.
42.5
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
2.
2.
2.
1.
1.
1.
1.
0.
0.
37.5
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
3.
3.
2.
2.
1.
1.
1.
1.
0.
0.
33.0
9.
9.
8.
8.
7.
6.
5.
5.
5.
5.
5.
5.
4.
4.
3.
3.
2.
2.
1.
1.
1.
0.
0.
29.0
79.
76.
71.
61.
44.
27.
17.
12.
9.
7.
6.
5.
5.
4.
4.
3.
2.
2.
1.
1.
1.
0.
0.
25.5
410.
401.
382.
342.
288.
224.
149.
90.
50.
28.
14.
7.
5.
4.
4.
3.
2.
2.
1.
1.
1.
0.
0.
22.5
892.
877.
839.
771.
676.
584.
477.
360.
243.
144.
61.
16.
7.
5.
4.
3.
2.
2.
1.
1.
1.
0.
0.
19.5
1444. 1446. 1400. 1323. 1214. 1085.
921.
732.
549.
384.
201.
58.
12.
5.
4.
3.
2.
2.
1.
1.
1.
0.
0.
17.0
1885. 1866. 1824. 1731. 1613. 1483. 1305. 1105.
883.
647.
399.
156.
29.
7.
4.
3.
2.
2.
1.
1.
1.
0.
0.
15.0
2533. 2520. 2417. 2225. 1999. 1774. 1580. 1386. 1152.
892.
570.
265.
64.
9.
4.
3.
2.
2.
1.
1.
1.
0.
0.
13.0
3690. 3634. 3465. 3114. 2667. 2226. 1875. 1623. 1396. 1125.
765.
392.
120.
11.
4.
3.
3.
2.
1.
1.
1.
0.
0.
11.0
5736. 5667. 5222. 4439. 3722. 2989. 2350. 1895. 1599. 1331.
963.
520.
185.
17.
4.
3.
3.
2.
1.
1.
1.
0.
0.
9.0
8019. 8017. 7601. 6662. 5379. 3967. 3002. 2282. 1809. 1499. 1133.
641.
258.
27.
5.
3.
3.
2.
1.
1.
1.
0.
0.
7.0
9420. 9373. 9015. 8344. 7228. 5414. 3777. 2758. 2054. 1646. 1273.
752.
325.
39.
6.
3.
3.
2.
1.
1.
1.
0.
0.
5.0 10357.10311. 9915. 9277. 8376. 6824. 4688. 3199. 2308. 1782. 1375.
850.
379.
52.
6.
3.
3.
2.
1.
1.
1.
0.
0.
3.0 10848.10814.10489. 9853. 9054. 7685. 5526. 3626. 2548. 1889. 1448.
920.
418.
63.
6.
3.
3.
2.
1.
1.
1.
0.
0.
1.0 11006.10972.10686.10121. 9354. 8080. 6054. 3921. 2711. 1952. 1493.
964.
440.
72.
7.
3.
3.
2.
1.
1.
1.
0.
0.
0.0 11011.10985.10718.10176. 9450. 8145. 6151. 3980. 2743. 1963. 1517.
970.
443.
73.
7.
4.
3.
2.
1.
1.
1.
0.
0.
-1.0 10989.10975.10713.10180. 9463. 8129. 6134. 3978. 2739. 1958. 1515.
968.
443.
73.
7.
4.
3.
2.
1.
1.
1.
0.
0.
-3.0 10872.10846.10590. 9990. 9253. 7859. 5750. 3783. 2622. 1913. 1470.
940.
426.
68.
6.
4.
3.
2.
1.
1.
1.
0.
0.
-5.0 10481.10448.10136. 9496. 8622. 7149. 5022. 3400. 2400. 1822. 1403.
881.
394.
57.
6.
4.
3.
2.
1.
1.
1.
0.
0.
-7.0
9647. 9610. 9312. 8682. 7639. 5954. 4094. 2942. 2142. 1703. 1308.
793.
342.
45.
6.
4.
3.
2.
1.
1.
1.
0.
0.
-9.0
8453. 8463. 8056. 7304. 6021. 4427. 3261. 2431. 1900. 1564. 1183.
683.
277.
32.
5.
4.
3.
2.
1.
1.
1.
0.
0.
-11.0
6537. 6483. 6007. 5109. 4123. 3299. 2570. 2023. 1689. 1407. 1024.
559.
208.
21.
5.
4.
3.
2.
1.
1.
1.
0.
0.
-13.0
4107. 4078. 3841. 3475. 2975. 2462. 2019. 1734. 1482. 1209.
847.
422.
140.
13.
5.
3.
3.
2.
1.
1.
1.
0.
0.
-15.0
2848. 2859. 2683. 2438. 2192. 1914. 1688. 1487. 1247.
984.
646.
301.
83.
9.
4.
3.
3.
2.
1.
1.
1.
0.
0.
-17.0
2077. 2069. 1998. 1873. 1726. 1591. 1422. 1227.
992.
740.
454.
184.
40.
8.
4.
3.
3.
2.
1.
1.
1.
0.
0.
-19.5
1568. 1571. 1530. 1456. 1350. 1217. 1054.
858.
642.
449.
250.
77.
14.
5.
4.
3.
3.
2.
1.
1.
1.
0.
0.
-22.5
1055. 1059. 1013.
932.
827.
692.
570.
439.
301.
184.
81.
20.
8.
5.
4.
3.
2.
2.
1.
1.
1.
0.
0.
-25.5
487.
490.
463.
421.
368.
291.
206.
132.
71.
38.
17.
7.
5.
5.
4.
3.
2.
2.
1.
1.
1.
0.
0.
-29.0
107.
109.
99.
84.
63.
40.
22.
13.
9.
7.
6.
5.
5.
4.
4.
3.
2.
2.
1.
1.
1.
0.
0.
-33.0
7.
7.
7.
6.
6.
6.
5.
5.
5.
5.
5.
5.
4.
4.
3.
2.
2.
2.
1.
1.
1.
0.
0.
-37.5
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
3.
3.
2.
2.
1.
1.
1.
1.
0.
0.
-42.5
2.
2.
2.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
2.
2.
2.
1.
1.
1.
1.
0.
0.
-47.5
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
1.
1.
1.
1.
1.
0.
0.
-55.0
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
2.
2.
2.
2.
2.
1.
1.
1.
1.
1.
0.
0.
0.
-65.0
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
0.
0.
0.
-75.0
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
-85.0
0.
0.
0.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
-90.0
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
BEAM EDGE =
FIELD EDGE =
5506. CP = 50% OF MAX
1101. CP = 10% OF MAX
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81791
ISSUE DATE: 06/10/14
PREPARED FOR: RAB LIGHTING, INC.
PAGE: 3 OF 7
CANDELA TABULATION - FIELD ONLY
AVERAGE OF RIGHT AND LEFT SIDES
0.0
1.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.5
22.5
25.5
29.0
33.0
37.5
42.5
47.5
55.0
65.0
75.0
85.0
90.0
90.0
85.0
75.0
65.0
55.0
47.5
42.5
37.5
33.0
29.0
25.5
22.5
19.5
1444. 1446. 1400. 1323. 1214.
17.0
1885. 1866. 1824. 1731. 1613. 1483. 1305. 1105.
15.0
2533. 2520. 2417. 2225. 1999. 1774. 1580. 1386. 1152.
13.0
3690. 3634. 3465. 3114. 2667. 2226. 1875. 1623. 1396. 1125.
11.0
5736. 5667. 5222. 4439. 3722. 2989. 2350. 1895. 1599. 1331.
9.0
8019. 8017. 7601. 6662. 5379. 3967. 3002. 2282. 1809. 1499. 1133.
7.0
9420. 9373. 9015. 8344. 7228. 5414. 3777. 2758. 2054. 1646. 1273.
5.0 10357.10311. 9915. 9277. 8376. 6824. 4688. 3199. 2308. 1782. 1375.
3.0 10848.10814.10489. 9853. 9054. 7685. 5526. 3626. 2548. 1889. 1448.
1.0 11006.10972.10686.10121. 9354. 8080. 6054. 3921. 2711. 1952. 1493.
0.0 11011.10985.10718.10176. 9450. 8145. 6151. 3980. 2743. 1963. 1517.
-1.0 10989.10975.10713.10180. 9463. 8129. 6134. 3978. 2739. 1958. 1515.
-3.0 10872.10846.10590. 9990. 9253. 7859. 5750. 3783. 2622. 1913. 1470.
-5.0 10481.10448.10136. 9496. 8622. 7149. 5022. 3400. 2400. 1822. 1403.
-7.0
9647. 9610. 9312. 8682. 7639. 5954. 4094. 2942. 2142. 1703. 1308.
-9.0
8453. 8463. 8056. 7304. 6021. 4427. 3261. 2431. 1900. 1564. 1183.
-11.0
6537. 6483. 6007. 5109. 4123. 3299. 2570. 2023. 1689. 1407.
-13.0
4107. 4078. 3841. 3475. 2975. 2462. 2019. 1734. 1482. 1209.
-15.0
2848. 2859. 2683. 2438. 2192. 1914. 1688. 1487. 1247.
-17.0
2077. 2069. 1998. 1873. 1726. 1591. 1422. 1227.
-19.5
1568. 1571. 1530. 1456. 1350. 1217.
-22.5
-25.5
-29.0
-33.0
-37.5
-42.5
-47.5
-55.0
-65.0
-75.0
-85.0
-90.0
BEAM EDGE =
FIELD EDGE =
5506. CP = 50% OF MAX
1101. CP = 10% OF MAX
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81791
ISSUE DATE: 06/10/14
PREPARED FOR: RAB LIGHTING, INC.
PAGE: 4 OF 7
LUMEN TABULATION
AVERAGE OF RIGHT AND LEFT SIDES
0
2
4
6
8
10
12
14
16
18
21
24
27
31
35
40
45
50
60
70
80
90
TOTAL
90
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
4.
2.
2.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
9.
3.
3.
2.
2.
2.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
17.
2.
2.
2.
2.
2.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
16.
3.
3.
3.
2.
2.
2.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
21.
4.
4.
4.
3.
3.
2.
2.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
28.
7.
6.
5.
5.
4.
3.
2.
2.
2.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
38.
10.
9.
8.
7.
5.
4.
3.
2.
2.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
52.
11.
11.
10.
9.
7.
5.
3.
2.
2.
2.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
64.
13.
12.
11.
10.
8.
6.
4.
3.
2.
2.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
73.
13.
13.
12.
11.
9.
7.
4.
3.
2.
2.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
79.
13.
13.
12.
11.
10.
7.
5.
3.
2.
3.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
82.
13.
13.
12.
11.
10.
7.
5.
3.
2.
3.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
83.
13.
13.
12.
11.
9.
7.
4.
3.
2.
3.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
81.
13.
12.
12.
10.
9.
6.
4.
3.
2.
2.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
75.
12.
11.
11.
9.
7.
5.
3.
3.
2.
2.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
67.
10.
10.
9.
7.
5.
4.
3.
2.
2.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
56.
8.
7.
6.
5.
4.
3.
2.
2.
2.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
43.
5.
5.
4.
4.
3.
2.
2.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
31.
3.
3.
3.
3.
2.
2.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
23.
3.
2.
2.
2.
2.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
18.
3.
3.
3.
2.
2.
2.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
19.
2.
2.
2.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
11.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
5.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
168.
162.
149.
132.
108.
81.
58.
43.
33.
35.
20.
8.
2.
0.
0.
0.
0.
0.
0.
0.
0.
999.
80
70
60
50
45
40
35
31
27
24
21
18
16
14
12
10
8
6
4
2
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
-21
-24
-27
-31
-35
-40
-45
-50
-60
-70
-80
-90
LUMEN TOTAL THIS PAGE =
999.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81791
ISSUE DATE: 06/10/14
PREPARED FOR: RAB LIGHTING, INC.
PAGE: 5 OF 7
LUMEN TABULATION - FIELD ONLY
AVERAGE OF RIGHT AND LEFT SIDES
0
2
4
6
8
10
12
14
16
18
21
24
27
31
35
40
45
50
60
70
80
90
TOTAL
90
0.
80
0.
70
0.
60
0.
50
0.
45
0.
40
0.
35
0.
31
0.
27
0.
24
0.
21
3.
3.
2.
2.
10.
2.
2.
2.
2.
2.
2.
1.
3.
3.
3.
2.
2.
2.
2.
1.
4.
4.
4.
3.
3.
2.
2.
2.
1.
7.
6.
5.
5.
4.
3.
2.
2.
2.
10.
9.
8.
7.
5.
4.
3.
2.
2.
2.
51.
11.
11.
10.
9.
7.
5.
3.
2.
2.
2.
62.
13.
12.
11.
10.
8.
6.
4.
3.
2.
2.
71.
13.
13.
12.
11.
9.
7.
4.
3.
2.
2.
77.
13.
13.
12.
11.
10.
7.
5.
3.
2.
3.
80.
13.
13.
12.
11.
10.
7.
5.
3.
2.
3.
80.
13.
13.
12.
11.
9.
7.
4.
3.
2.
3.
78.
13.
12.
12.
10.
9.
6.
4.
3.
2.
2.
73.
12.
11.
11.
9.
7.
5.
3.
3.
2.
2.
65.
10.
10.
9.
7.
5.
4.
3.
2.
2.
2.
54.
8.
7.
6.
5.
4.
3.
2.
2.
2.
39.
5.
5.
4.
4.
3.
2.
2.
2.
1.
28.
3.
3.
3.
3.
2.
2.
2.
1.
3.
2.
2.
2.
2.
2.
1.
3.
3.
3.
2.
2.
18
13.
16
18.
14
25.
12
35.
10
8
6
4
2
0
-2
-4
-6
-8
-10
-12
-14
20.
-16
14.
-18
13.
-21
0.
-24
0.
-27
0.
-31
0.
-35
0.
-40
0.
-45
0.
-50
0.
-60
0.
-70
0.
-80
0.
-90
163.
156.
144.
127.
102.
74.
53.
37.
27.
23.
0.
LUMEN TOTAL THIS PAGE =
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
907.
907.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
•
REPORT NUMBER: ITL81791
ISSUE DATE: 06/10/14
PREPARED FOR: RAB LIGHTING, INC.
WEBSITE: www.itlboulder.com
PAGE: 6 OF 7
ISOCANDELA CURVES
AVERAGE OF RIGHT AND LEFT SIDES
30
0
3
6
9
12
15
18
21
24
27
30
27
24
21
10000
9000
18
15
7000
5505 (= 50% MAX)
12
9
4000
3000
2000
6
1101 (= 10% MAX)
3
0
-3
-6
-9
-12
-15
-18
-21
-24
-27
-30
0
3
6
9
12
15
18
21
24
27
30
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
REPORT NUMBER: ITL81791
ISSUE DATE: 06/10/14
PREPARED FOR: RAB LIGHTING, INC.
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
PAGE: 7 OF 7
ADDRESS: 170 LUDLOW AVE
NORTHVALE, NJ 07647
THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY
THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT
BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
•
FAX: (970)535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER:
DATE:
PREPARED FOR:
CATALOG NUMBER:
ITL81818
06/19/14
RAB LIGHTING, INC.
HSLED18 (SPOT)
Page 1 of 4
ADDRESS:
170 LUDLOW AVE
NORTHVALE, NJ 07647
LUMINAIRE:
CAST METAL HOUSING, BROWN PAINTED FLAT METAL HEAT SINK MOUNTING
PLATE, CAST BROWN PAINTED FINNED METAL HEAT SINK, 1 CIRCUIT BOARD
WITH 1 LED, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH, CLEAR
FLAT GLASS LENS IN CAST BROWN PAINTED METAL FRAME.
LAMP:
ONE WHITE MULTI-CHIP LIGHT EMITTING DIODE (LED), AIMED AT THE
HORIZON.
DRIVER:
RAB LIGHTING RD12-36-A0500
NOTE:
DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT
VOLTAGE (120.0 AND 277.0 VAC, 60Hz) TO THE DRIVER.
Calibration Due:
Associated Power Technologies APT5040 AC Power Source
N/A
Yokogawa WT210 Digital Power Meter #8
12/31/14
Ocean Optics QE65000 Spectroradiometer
04/13/14
ITL 2.0m Diameter Integrating Sphere S20-2, 4PI Geometry 04/13/14
INSTRUMENTS:
OBJECT OF TEST:
Measure the Total Radiant Flux*, Spectral Power Distribution (SPD),
Correlated Color Temperature (CCT), Color Rendering Indices (CRIa,1-14),
Chromaticity Coordinates (x,y; u’v’), ANSI C78.377 Duv, and electrical
data including ANSI C82.77-2002 Power Factor (PF) and Total Harmonic
Distortion (THD) to the test sample. Report Off-State Power. Measure
electrical data including Total Harmonic Distortion (THD) at maximum
rated voltage.
PROCEDURE:
The test sample was provided by the customer and had an unknown number
of operating hours. The test sample was mounted inside the integrating
sphere and allowed to stabilize. After stabilization occurred,
measurements were taken. In order to measure mean performance, multiple
data sets were recorded and averaged. Readings were taken with the test
sample operating at 120.0 VAC input. Electrical data was also recorded
at maximum nominal rated input voltage (277.0 VAC). All testing
performed in a 25 +/-1 degree Celsius free air ambient and in
accordance with IESNA LM-79-08. All data are traceable to the National
Institute of Standards and Technology. Off-State Power was reported
with no voltage applied to the sample.
*NOTE:
Proper calibration of integrating spheres for measuring total flux
output of non-directional samples will produce reliable, repeatable
results within the calibration tolerances of the equipment used.
However, measurement of test samples with significant self absorption
and/or directional output, even when these effects are compensated
for, are likely to have a greater variation in results compared to
the flux output calculated from a goniophotometric exploration since
these artifacts do not affect the goniophotometric results.
RESULTS:
(continued subsequent pages)
THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM
PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE
FEDERAL GOVERNMENT.
Checked
Approved
N THOMAS
P O’CONNOR
Sphere Lab Supervisor
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER:
DATE:
PREPARED FOR:
CATALOG NUMBER:
•
FAX: (970)535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
ITL81818
06/19/14
RAB LIGHTING, INC.
HSLED18 (SPOT)
•
WEBSITE: www.itlboulder.com
Page 4 of 4
CIE Chromaticity Diagram
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER:
DATE:
PREPARED FOR:
CATALOG NUMBER:
•
FAX: (970)535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
ITL81818
06/19/14
RAB LIGHTING, INC.
HSLED18 (SPOT)
•
WEBSITE: www.itlboulder.com
Page 2 of 4
RESULTS:
SPECTRORADIOMETRIC
Observer
Chromaticity Ordinate x
Chromaticity Ordinate y
Observer
Chromaticity Ordinate u’
Chromaticity Ordinate v’
Correlated Color Temp CCT (K)
ANSI C78.377-2008 Duv
Total Radiant Flux (milliWatts)
CIE 1931 2 degree
0.3446
0.3835
CIE 1976 2 degree
0.1994
0.4993
5107
0.015
5621 *
ELECTRICAL
Input Voltage (Volts AC)
Input Current (Amps AC)
Input Power (Watts)
Input Power Factor (%)
Input Current THD (%)
Input Voltage THD (%)
120.0
0.166
19.8
99.4
10.3
0.1
Off-State Power (Watts)
0.0
ELECTRICAL AT MAX NONIMAL INPUT
Input Voltage (Volts AC)
Input Current (Amps AC)
Input Power (Watts)
Input Power Factor (%)
Input Current THD (%)
Input Voltage THD (%)
*NOTE:
COLOR RENDERING INDICES
Ra (Average 1-8)
R1 Light greyish red
R2 Dark greyish yellow
R3 Strong yellowish green
R4 Moderate yellowish green
R5 Light bluish green
R6 Light blue
R7 Light violet
R8 Light reddish purple
R9 Strong red
R10 Strong yellow
R11 Strong green
R12 Strong blue
R13 Light yellowish pink (skin)
R14 Moderate olive green (leaf)
CRI
68
62
73
82
66
63
63
83
51
-52
37
60
30
64
90
277.0
0.080
20.3
91.6
20.5
0.1
Proper calibration of integrating spheres for measuring total flux
output of non-directional samples will produce reliable, repeatable
results within the calibration tolerances of the equipment used.
However, measurement of test samples with significant self absorption
and/or directional output, even when these effects are compensated
for, are likely to have a greater variation in results compared to
the flux output calculated from a goniophotometric exploration since
these artifacts do not affect the goniophotometric results.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER:
DATE:
PREPARED FOR:
CATALOG NUMBER:
•
FAX: (970)535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
ITL81818
06/19/14
RAB LIGHTING, INC.
HSLED18 (SPOT)
•
WEBSITE: www.itlboulder.com
Page 3 of 4
RESULTS:
Wavelength
380
385
390
395
400
405
410
415
420
425
430
435
440
445
450
455
460
465
470
475
480
485
490
495
500
505
510
mW per nm
0.148
0.155
0.164
0.188
0.246
0.365
0.627
1.152
2.166
3.965
7.033
11.744
18.395
28.894
41.247
43.016
31.400
20.497
14.465
10.186
7.397
6.337
6.475
7.681
10.191
13.854
18.163
Wavelength
515
520
525
530
535
540
545
550
555
560
565
570
575
580
585
590
595
600
605
610
615
620
625
630
635
640
645
mW per nm
22.405
26.157
29.195
31.425
32.905
33.831
34.325
34.506
34.463
34.212
33.811
33.231
32.466
31.578
30.476
29.217
27.846
26.347
24.800
23.204
21.521
19.874
18.261
16.665
15.165
13.746
12.375
Wavelength
650
655
660
665
670
675
680
685
690
695
700
705
710
715
720
725
730
735
740
745
750
755
760
765
770
775
780
mW per nm
11.120
9.972
8.895
7.917
7.030
6.230
5.502
4.858
4.281
3.776
3.308
2.905
2.549
2.236
1.961
1.717
1.500
1.310
1.150
1.011
0.888
0.778
0.684
0.600
0.528
0.462
0.406
Output vs. Wavelength
45.0
Output (mW/nm)
36.0
27.0
18.0
9.0
0.0
380.0
420.0
460.0
500.0
540.0 580.0 620.0
Wavelength (nm)
660.0
700.0
740.0
780.0
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.