fcr1 spec eng

fcr1 spec eng
FC Series Signal Conditioners
PLC
Overview
DL05/06
PLC
Panel or DIN rail mountable
Convert, isolate and transmit
your process signals
Removable terminal blocks
Not all electrical signals are created equal. That’s
why the FC series signal conditioners are the
perfect solution for converting process, temperature and other electrical signals into voltage or
current signals for transmission or input to a PLC.
The FC series signal conditioners offer 1500V
isolation between the input and output to help
eliminate electrical noise. Features include easily
accessible potentiometer adjustment of the output
span and offset, (with the exception of FC-33),
slim DIN-rail or side-mount cases and removable
terminal blocks.
Calibration button
allows “one-touch
automatic calibration”
based on incoming
signals
Easily accessible DIP
switches
The FC series signal conditioners are ideal for use
with PLCs, loop controllers, digital displays and
any other applications requiring an isolated or
analog signal.
DL105
PLC
DL205
PLC
DL305
PLC
DL405
PLC
Field I/O
Software
C-more
HMIs
Other HMI
AC Drives
Motors
Steppers/
Servos
Wiring diagrams and switch settings on the product,
no manual required
Motor
Controls
FC-33
<--->
DC Selectable Signal Conditioner with
3-way isolation
Field configurable input and output ranges of 0-5V, 0-10V, 0-20
mA and 4-20 mA with 1500 VDC isolation between input and
output, and 1500 VDC isolation from 24 volt power and
input/output. LED indicates normal operation and is used in
conjunction with the calibration pushbutton for the internal calibration process.
• 3-way 1500V isolation
• Push button calibration
FC-T1
<--->
Thermocouple/mV Isolated Signal
Conditioner
Field configurable input for several different types of thermocouple or mV inputs with 1500 VDC isolation between input
and output. Cold junction compensation and burnout detection.
Alarm/run LED.
• 1500V isolation
• Cold junction compensation (CJC)
• Internal diagnostics (burnout detection or calibration errors)
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pushbuttons/
Lights
Process
FC-11
<--->
4-20 mA Isolated Signal Conditioner
Loop powered 4-20 mA input/output signal with
1500 VDC isolation between input and output.
• 1500V isolation
• Loop powered
FC-R1
<--->
RTD Input Signal Conditioner
Loop powered, non-isolated, 3-wire unit converts an RTD input
to a linear 4-20 mA signal. User selectable CU10, PT100 or
PT1000 input.
Relays/
Timers
Comm.
TB’s &
Wiring
Power
Circuit
Protection
Enclosures
Appendix
Part Index
w w w. a u to m at i o n d i re c t . c o m / s i g n a l _ c o n d i t i o n e rs
Process Control
23–19
FC-R1 RTD Input Loop Powered Signal
Conditioner
Specifications
Input Ranges
Common Mode Range
Output Range
The FC-R1 is a DIN-rail or side-mount
Resistive Temperature Detector signal
conditioner. It is a non-isolated signal conditioner which converts a 3-wire RTD to a
linearized 4-20 mA current loop signal.
The FC-R1 has a user selectable CU10 (10
Ohm copper), PT100 (100 Ohm platinum) or
PT1000 (1000 Ohm platinum) RTD input,
and also offers OFFSET (zero) and SPAN (full
scale) adjustments of the output signal. The
OFFSET has an adjustment range of 0 to 25%
of full scale output and the SPAN has an
adjustment of 80% to 102%.
-328°F to 500°F
PT100
-200°C to 850°C
-328°F to 1562°F
PT1000
-200°C to 595°C
-328°F to 1103°F
0 - 3.5 VDC
4-20 mA (linearized)
0.35% FSO / CU10
0.2% FSO @ 25°C / PT100 & PT1000
0.26% FS0 @ 60°C / PT100 & PT1000
Maximum Inaccuracy
Overview
-200°C to 260°C
CU10, PT100 500 µA ±50 µA
PT1000 80 µA ±20 µA
RTD Excitation Current
<--->
CU10
Maximum Loop Supply
Load Impedance
Maximum Load/Power Supply
30 VDC
0 minimum
203 / 12 V, 745 / 24 V
0.35% FSO / CU10
0.2% FSO / PT10 & PT1000
Linearity Error
Output Slew Rate
Filter Characteristics
Stability
Operating Temperature
Storage Temperature
Relative Humidity
Environmental Air
Vibration
Shock
Noise Immunity
1% @ 20 mS
105 dB @ DC, 60 dB @ 10 Hz, 40 dB @ 60Hz
0.05% FSO maximum
0 to 60°C (32 to 140°F)
-20 to 70°C (-4 to 158°F)
5 to 90% (non-condensing)
No corrosive gases permitted
ML STD 810C 514.2
ML STD 810C 516.2
NEMA ICS3-304
See page 23–23 for signal conditioner dimensions.
Ty p i c a l U s e r W i r i n g
Application
The FC-R1 field configurable input signal conditioner is useful for
interfacing RTD sensors to PLC analog current input modules. It is
recommended that shielded RTD’s be used whenever possible to
minimize noise on the input signal.
20mA
Output Current
Red
(+)
Red (if applicable)
12mA
Black
Black
4mA
-200˚C
325˚C
Process Control
(-)
(COM)
-
+
Module
Supply
24VDC
850˚C
Input Temperature - PT100 type RTD
23–24
No Connection
(if sensor has 4 leads,
only connect one lead to +)
RTD Signal Conditioner to 4-20 mA DL05/06 analog module
Only use three wire and four wire RTDs.
1 - 80 0 - 633 - 0405
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement