Product Specifications L4NR L4NR--PS PS

Product Specifications L4NR L4NR--PS PS
Product Specifications
L4NR
L4NR--PS
Type N Male Right Angle Positive Stop™ for 1/2 in LDF4­50A cable General Specifications
Interface N Male Body Style Right angle Brand HELIAX® |
Mounting Angle Right angle Ordering Note CommScope® standard product (Global) Positive Stop™ Electrical Specifications
Connector Impedance 50 ohm Operating Frequency Band 0 – 8800 MHz Cable Impedance 50 ohm 3rd Order IMD, typical ­116 dBm @ 910 MHz 3rd Order IMD Test Method Two +43 dBm carriers RF Operating Voltage, maximum (vrms) 707.00 V dc Test Voltage 2000 V Outer Contact Resistance, maximum 0.30 mOhm Inner Contact Resistance, maximum 2.00 mOhm Insulation Resistance, minimum 5000 MOhm Average Power 0.6 kW @ 900 MHz Peak Power, maximum 10.00 kW Insertion Loss, typical 0.05 dB Shielding Effectiveness ­110 dB ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 3
May 2, 2016
Product Specifications
L4NR
L4NR--PS
Outline Drawing
Mechanical Specifications
Outer Contact Attachment Method Self­flare Inner Contact Attachment Method Captivated Outer Contact Plating Trimetal Inner Contact Plating Gold
Interface Durability 500 cycles Interface Durability Method IEC 61169­4:9.5 Connector Retention Tensile Force 890 N
Connector Retention Torque 5.42 N­m
Pressurizable No Coupling Nut Proof Torque 4.52 N­m
|
40.00 in lb Coupling Nut Retention Force 444.82 N
|
100.00 lbf |
Silver |
200 lbf |
48.00 in lb Coupling Nut Retention Force Method MIL­C­39012C­3.23, 4.6.22 Dimensions
Nominal Size 1/2 in Height 46.09 mm
|
1.81 in Length 75.31 mm
|
2.96 in Right Angle Length 22.60 mm
|
0.89 in Weight 133.10 g
Width 23.50 mm
|
0.29 lb |
0.93 in Environmental Specifications
Operating Temperature ­55 °C to +85 °C (­67 °F to +185 °F) Storage Temperature ­55 °C to +85 °C (­67 °F to +185 °F) Immersion Depth 1 m ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 3
May 2, 2016
Product Specifications
L4NR
L4NR--PS
Immersion Test Mating Unmated Immersion Test Method IEC 60529:2001, IP68 Water Jetting Test Mating Unmated Water Jetting Test Method IEC 60529:2001, IP66 Moisture Resistance Test Method MIL­STD­202F, Method 106F Mechanical Shock Test Method MIL­STD­202F, Method 213B, Test Condition C Thermal Shock Test Method MIL­STD­202F, Method 107G, Test Condition A­1, Low Temperature ­55 °C Vibration Test Method MIL­STD­202F, Method 204D, Test Condition B Corrosion Test Method MIL­STD­1344A, Method 1001.1, Test Condition A Standard Conditions
Attenuation, Ambient Temperature 20 °C
|
68 °F Average Power, Ambient Temperature 40 °C
|
104 °F Return Loss/VSWR
Frequency Band
50–1000 MHz
1000–1900 MHz
1900–2200 MHz
2200–2700 MHz
2700–3600 MHz
3600–6000 MHz
6000–8800 MHz
VSWR
1.02
1.04
1.05
1.08
1.10
1.12
1.29
Return Loss (dB)
­39.00
­34.00
­32.00
­28.00
­26.00
­25.00
­18.00
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
China RoHS SJ/T 11364­2006
ISO 9001:2008
Classification
Compliant by Exemption
Above Maximum Concentration Value (MCV)
Designed, manufactured and/or distributed under this quality management system
* Footnotes
Immersion Depth Immersion at specified depth for 24 hours Insertion Loss, typical 0.05v¯freq (GHz) (not applicable for elliptical waveguide) ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 3 of 3
May 2, 2016