Operating and Wiring Instructions
D I G I TA L
LIGHTING
SYSTEMS
MC120 INSTALLATION INSTRUCTIONS
120 VAC
TERMINAL STRIP
C
N
H
1
2
3
4
MCSERIES
RUN RATE
PATTERN
SELECTOR
DIGITAL LIGHTING SYSTEMS, INC.
Miami, Fl. U.S.A.
GENERAL SPECIFICATIONS
INPUT SPECIFICATIONS:
110-120 VAC ONLY.
LOAD #1
Neut. Hot
120 VAC
Input
MAXIMUM LOAD PER OUTPUT:
MC120: 2.5 Amps. (4 x 300W)
(MC120-1P 7.0 Amps.)
LOAD #2
LOAD #3
LOAD #4
INTERNAL F USE R ATING:
Maximum 10 Amps/ @ Min. 125 VAC.
ENCLOSURE SIZE:
4.5” x 4.5” x 2.5” Aluminum Enclosure
Covers a Standard 1900 Box.
120 VAC LOADS
Terminal Strip Legend
C
N
H
1-4
Common Out.
Neutral Input.
Hot Input.
Outputs 1 to 4.
CAUTION
1
2
3
This unit must be installed by qualified personnel in accordance
with NEC and all local Codes.
All connections must be made with suitable size copper conductor
wires with 90ºC wire insulation.
Terminal strip connections must be well tightened.
DIGITAL LIGHTING SYSTEMS, INC.
7588 NW 8th Street, Miami, Fl. 33126, Ph: (305) 264 -8391
MC120 Four-Channel Multi-Pattern Chaser
WIRING DIAGRAM FOR 120 VAC
Date: 11-25-02 Drawing#: MC120WRG Page: 1
www.digitallighting.com
Was this manual useful for you? yes no
Thank you for your participation!