Control Panel
Model A
INSTALLATION 81 OPERATING INSTRUCTIONS
iiFc?-l
This bulletin should be used by
experienced personnel as a guide to
the installation of Control Panel A.
Selection or installation of equipment should always be accompanied
by competent technical assistance.
You are encouraged to contact
Armstrong International, Inc. or its
local sales representative for addi-
Figure l-1
4.
5.
tional information.
6.
Installtition
1. An Armstrong Liquid Drainer
is recommended to drain
liquid from the air supply line
to the panel.
2. An Armstrong AF-10 filter
with a 5 micro filter should be
installed in the air line going
to the A-panel to reduce the
chance of dirt fouling the
instrumentation regulator.
3. A l/4” ball valve should be
installed before the AF-10 for
7.
ease of maintenance and
troubleshooting.
Install the Control Panel A in
a location that is accessible for
maintenance.
Install the Control Panel A
making sure the shop air is
connected to the automatic
drain on the back of the panel.
Connect the air line from the
bottom of the regulator (out)
on the back of the panel to the
top of the air loaded pressure
reducing valve or control
valve.
Connect the delivery pressure
gauge (A) on the top of the
panel to the downstream
sensing line “T” pipe fitting as
shown in Figure 1 - 1.
1.
2.
3,
4,
5.
6.
Control Panel Model A
Operation
Note: Be sure to follow the
manufacturers’ instructions
7.
for installation of the Pressure
Reducing Valve.
Open the valve on the drip leg
to allow the liquid drainer to
drain any liquid at the inlet of
Control Panel A.
Open the l/4” ball valve to the
filter and Control Panel A.
Using the Panel Regulator
Knob (R) on the front of the
panel, set the air loading
pressure to the PRV.
Open the valve slowly on the
outlet side of the PRV and
also on the sensing line.
Open the inlet valve to the
PRV slowly to avoid water
hammer and potential
diaphragm damage.
Adjust the air loading pressure
until the desired outlet
pressure is achieved on the
Delivery Pressure Gauge (A).
After the entire system
stabilizes, adjust again if
required.
Control Panel
Model Y
INSTALLATION & OPERATING INSTRUCTIONS
kch
This bulletin should be used by
experienced personnel as a guide to
the installation of Control Panel Y.
Selection OY installation of equipment should always be accompanied
by competent technical assistance.
You are encouraged to contact
Armstrong International, Inc. or its
local sales representative for additional information.
Control Panel Model Y
Installation
1. An Armstrong Liquid Drainer
is recommended to drain
liquid from the air supply line
to the panel.
2. An Armstrong AF-10 filter
with a 5 micro filter should be
installed in the air line going
to the Y-Panel to reduce the
chance of dirt fouling the
instrumentation regulator.
3. A 114” ball valve should be
installed before the AF- 10 for
Armstrong International, Inc.
Bulletin NO. AY-774-A 3195
l
ii
Figure 2-1
ease of maintenance and
troubleshooting.
4. Install the Control Panel Y in
a location that is accessible for
maintenance.
5. Install the Control Panel Y
making sure the shop air is
connected to the automatic
drain on the back of the panel.
6. Connect the air line from the
bottom of the regulator (out)
on the back of the panel to the
top of the air loaded pressure
reducing valve or control
valve.
Control Panel Model Y
Operation
Note: Be sure to follow the
manufacturers’ instructions
for installation of the Pressure
Reducing Valve.
1. Open the valve on the drip leg
to allow the liquid drainer to
drain any liquid at the inlet of
Control Panel Y.
2. Open the l/4” ball valve to the
filter and Control Panel Y.
3. Using the Panel Regulator
Knob (R) on the front of the
panel, set the air loading
pressure to the PRV.
4. Open the valve slowly on the
outlet side of the Pressure
Reducing Valve and also on
the sensing line.
5. Open the inlet valve to the
PRV slowly to avoid water
hammer and potential
diaphragm damage.
6. Adjust the air loading pressure
until the desired outlet
pressure is achieved on the
downstream pressure gauge.
7. After the system stabilizes,
adjust again if required.