Touch-sAfe heATers Accessories inDusTrY sTAnDArDs APPlicATion

Touch-sAfe heATers Accessories inDusTrY sTAnDArDs APPlicATion
Accessories Enclosure Heaters
Cooling
Accessories
Enclosure Heaters
Spec-00051
N63.422.2211
7
763.576.3200
Touch-Safe Heaters
INDUSTRY STANDARDS
cURus Component Recognized; File No. E150057
IP 20
CE
APPLICATION
Protect electronic, mechanical equipment from low temperatures,
condensation, and corrosion with this heater, which will maintain
stable enclosure temperatures by using natural convection
resulting in current circulation of warm air.
SPECIFICATIONS
•
•
•
•
eating element PTC resistor - temperature limiting
H
Double Insulated Protection
Mounting clip for 35mm DIN rail, EN 60 715
Vertical mount
FINISH
•
UL 94 V-0 Black Plastic Housing
Performance Data CATALOG NUMBERS
Electrical Data
Rated Voltage (AC/DC)
Power Consumption (Watts)
Start Nominal Current (Amps)
Unit Construction
H x W x D (in./mm)
Weight (oz)
1
Cooling
DAH101TS
DAH201TS
DAH501TS
110/120
10
2.5
110/120
20
4.5
110/120
50
8
3.9 X 1.5 X 3.0/98 x 38 x 75
5.0
3.9 X 1.5 X 3.0/98 x 38 x 75
6.1
4.3 X 2.4 X 3.5/110 x 60 x 90
10.4
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00051 N
Accessories Enclosure Heaters
Semiconductor Heaters
INDUSTRY STANDARDS
SPECIFICATIONS
•
•
cURus Component Recognized; File No. E150057
IEC IP54
CE
TC (Positive Temperature Coefficient) heating element
P
Mounting clip for 35-mm DIN rails EN 50022
FINISH
•
APPLICATION
Black anodized, extruded aluminum.
Protect electronic, pneumatic, hydraulic and mechanical equipment
from low temperatures, condensation and corrosion with this
heater, which maintains a stable enclosure temperature.
Performance Data Semiconductor Heater
CATALOG NUMBERS
ELECTRICAL DATA
Rated Voltage
Power Consumption (Watts)
Start Nominal Current (Amps)
HEATING PERFORMANCE
Watts
UNIT CONSTRUCTION
L (in./mm)
Weight (lb./kg)
EQUIPMENT PROTECTION
Spec-00051 N
DAH101
DAH301
DAH601
AC/DC 110/120
10
0.8
AC/DC 110/120
30
1.2
AC/DC 110/250
60
2.5
10
30
60
1.97/50
0.45/0.20
3.93/100
0.66/0.30
5.5/140
1.10/0.50
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
2
Accessories Enclosure Heaters
3
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00051 N
Accessories Enclosure Heaters
Electric Heaters
115/230 Volt
100/200 Watt
115/230 Volt
400/800 Watt
115/230 Volt
1300 Watt
INDUSTRY STANDARDS
UL 508A Component Recognized; File No. E61997
CSA Certified, CSA File No. LR42186
CE
APPLICATION
Protect mechanical, electrical and electronic equipment
from low temperatures, condensation and corrosion with this
thermostatically controlled, fan-driven heater that maintains a
stable enclosure temperature.
Fan draws cool air from the bottom of the enclosure and passes
this air across the thermostat and heating element before being
released into enclosure cavity. Heated air is discharged through the
top of the heater unit.
SPECIFICATIONS
•
•
•
•
•
Aluminum housing
T hermostat range adjustable from 0 F to 100 F (-18 C to 38 C)
Four 10-32 x self-tapping screws are included with each heater
Ball bearing fan
Terminal strip with clamp connector that accepts both solid and
stranded wire
CAUTION
These electric heaters are not designed for use in dusty,
dirty, corrosive, or hazardous locations. Portions of the
heater can get hot. Adequate protection must be taken
to protect people from potential burns, and to protect
other components from this heat. Pentair Technical
Products recommends this heater only be installed in a
totally-enclosed metal enclosure.
DO NOT INSTALL HEATERS ON WOOD PANELS.
Heat sensitive components should not be placed near the
heater discharge area since this air can be quite warm.
The clearance range defines the space that must be kept
free of these components for proper and safe operation
of the heater.
FINISH
•
Brushed aluminum
EQUIPMENT PROTECTION
Spec-00051 N
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
4
Accessories Enclosure Heaters
Performance Data 100 and 200 Watt Heaters
CATALOG NUMBERS
ELECTRICAL DATA
Rated Voltage
Frequency (Hz)
Power Consumption (Watts)
Nominal Current (Amps)
HEATING PERFORMANCE
Watts
UNIT CONSTRUCTION
Weight (lb./kg)
X (in./mm)
DAH1001A
DAH1002A
DAH2001A
DAH2002A
115
50/60
100
0.98
230
50/60
100
0.49
115
50/60
200
1.89
230
50/60
200
0.95
100
100
200
200
1.6/0.73
4.00/102
1.6/0.73
4.00/102
1.6/0.73
6.00/152
1.6/0.73
6.00/152
DAH4001B
DAH4002B
DAH8001B
DAH8002B
115
50/60
400
3.72
230
50/60
400
1.86
115
50/60
800
7.37
230
50/60
800
3.69
400
400
800
800
2.2/1.00
6.00/152
2.2/1.00
6.00/152
2.2/1.00
8.00/203
2.2/1.00
8.00/203
Performance Data 400 and 800 Watt Heaters
CATALOG NUMBERS
ELECTRICAL DATA
Rated Voltage
Frequency (Hz)
Power Consumption (Watts)
Nominal Current (Amps)
HEATING PERFORMANCE
Watts
UNIT CONSTRUCTION
Weight (lb./kg)
X (in./mm)
Performance Data 1300 Watt Heaters
CATALOG NUMBERS
ELECTRICAL DATA
Rated Voltage
Frequency (Hz)
Power Consumption (Watts)
Nominal Current (Amps)
HEATING PERFORMANCE
Watts
UNIT CONSTRUCTION
Weight (lb./kg)
X (in./mm)
5
Cooling
DAH13001C
DAH13002C
115
50/60
1300
11.5
230
50/60
1300
5.7
1300
1300
3.4/1.54
8.00/203
3.4/1.54
8.00/203
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00051 N
Accessories Enclosure Heaters
EQUIPMENT PROTECTION
Spec-00051 N
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
6
Accessories Enclosure Heaters
'LPHQVLRQVDQG&OHDUDQFH5DQJH'UDZLQJIRU'$+&DQG'$+&
;
;
7(50,1$/675,3:,7+
&/$03&211(&725
;
'5,//;
7$325
86(6(/)7$33,1*
6&5(:63529,'('
7
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00051 N
Accessories Enclosure Heaters
Hazardous Location Heater, ATEX
INDUSTRY STANDARDS
FEATURES
APPLICATION
•
•
•
•
•
•
•
CE
Conformity Certificate LCIE (Laboratoire Central des Industries
Electriques) LCIE 01 ATEX 6073
EEx d IIC T4/II 2 GD, IP6x T135°C
IEC 60529, IP65/I (grounded)
Designed for use in hazardous locations where electronic
components require protection from condensation and corrosion,
sudden temperature drops and low temperatures.
Maintenance-free
High-performance heating cartridge (element)
L arge convection surface
E xtruded aluminum heat sink
DIN clip for mounting
Connection cable: Si HF-JZ 3 x AWG 18 x 3.3 ft. (0.75 mm² x 1 m)
Operating voltage 110-120 VAC
FINISH
•
Black anodized
Performance Data Hazardous Location Heater
CATALOG NUMBERS
HLHEAT100
DESIGN DATA
Heating Power (Watts)
Surface Temperature T4 (°F/°C) *
UNIT CONSTRUCTION
Unit Dimensions - H x W x D (in. / mm)
100
275/135
7.10/180 x 4.65/118 x 2.70/69
* Surface temperature when mounted vertically.
EQUIPMENT PROTECTION
Spec-00051 N
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
8
Accessories Enclosure Heaters
Hazardous Location Heaters
INDUSTRY STANDARDS
CE
ATEX, IECEx
II2G Ex d IIC T3 / II2 D Ex Td A21 IP65 T200 C
NEC CSA us
Class I, Div 1 Groups A, B, C, D / Class II Div 1 Groups E, F, G
APPLICATION
Designed for use in hazardous locations where electronic
components require protection from cold freezing temperatures,
condensation and corrosion.
SPECIFICATIONS
•
•
•
•
•
•
0W, 80W, 200W, 300W, 400W and 600W models available
5
Provides freeze protection down to -76 F / -60 C
Conductive and Convection heating types available
5 0W and 80W models can be mounted directly to manifolds,
measuring or analyzing instruments, control valves, and similar
equipment
2 00W, 300W, 400W, 600W models are finned heaters that heat the
area by transferring the heat from the heater to surrounding air,
creating a convection current.
Two thermostat options available with a 50 F / 10 C or 68 F / 20 C
set point
FINISH
•
Black Anodized Aluminum
Performance Data 50W and 80W Hazardous Location Heaters
CATALOG NUMBERS
HEATING PERFORMANCE
Watts
Heating Type
Power Regulation
HAZARDOUS LOCATION CERTIFICATION
Temperature Classification (T Code)
Agency Approvals
ATEX / IECEx Certification
NEC CSA us Certification
ELECTRICAL DATA
Rated Voltage (VAC or VDC)
Operating Range
Maximum (F/C)
Minimum (F/C)
UNIT CONSTRUCTION
Material
ACCESSORIES
Thermostat*
UNIT DIMENSIONS
Height (in./mm)
Width (in./mm)
Depth (in./mm)
Weight (lb./kg)
DAHHL501AC
DAHHL801AC
50
Conductive
Self Limiting
80
Conductive
Self Limiting
T4
T3
ATEX, IECEx, CSA us
II2G Ex d IIC T3 / II2 D Ex Td A21 IP65 T200 C
Class I, Div 1 Groups A, B, C, D / Class II Div 1 Groups E, F, G
110 - 265
110 - 265
302/150
-76/-60
302/150
-76/-60
Black anodized sea water proof aluminium
HLTSTAT10C, HLTSTAT20C
3.5/190
1.6/40
1.2/30
1.1/.50
3.5/190
1.6/40
1.2/30
1.1/.50
Thermostats sold separately as an accessory.
9
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00051 N
Accessories Enclosure Heaters
Performance Data 200W, 300W, 400W, 600W Hazardous Location Heaters
CATALOG NUMBERS
DAHHL200AC
HEATING PERFORMANCE
Watts
200
Heating Type
Convection
Power Regulation
Self Limiting
HAZARDOUS LOCATION CERTIFICATION
Temperature Classification (T Code)
T3
Agency Approvals
ATEX / IECEx Certification
NEC CSA us Certification
ELECTRICAL DATA
Rated Voltage (VAC or VDC)
110 - 265
Operating Range
302/150
Maximum ( F/C)
-76/-60
Minimum (F/C)
UNIT CONSTRUCTION
Material
ACCESSORIES
Thermostat*
UNIT DIMENSIONS
Height (in./mm)
8.9/225
Width (in./mm)
9.0/229
Depth (in./mm)
2.4/60
Weight (lb./kg)
8.7/3.95
DAHHL300AC
DAHHL4001A
DAHHL4002A
DAHHL6001A
DAHHL6002A
300
Convection
Self Limiting
400
Convection
Constant Power
400
Convection
Constant Power
600
Convection
Constant Power
600
Convection
Constant Power
T3
T3
110 - 265
108 - 132
207 -253
108 - 132
207 -253
302/150
-76/-60
302/150
-76/-60
302/150
-76/-60
302/150
-76/-60
302/150
-76/-60
12.8/325
9.0/229
2.4/60
12.5/5.65
12.8/325
9.0/229
2.4/60
12.5/5.65
T3
T3
ATEX, IECEx, CSA us
II2G Ex d IIC T3 / II2 D Ex Td A21 IP65 T200 C
Class I, Div 1 Groups A, B, C, D / Class II Div 1 Groups E, F, G
T3
Black anodized sea water proof aluminium
HLTSTAT10C, HLTSTAT20C
12.8/325
9.0/229
2.4/60
12.5/5.65
8.9/225
9.0/229
2.4/60
8.7/3.95
8.9/225
9.0/229
2.4/60
8.7/3.95
* A thermostat is required for 400W and 600W models. It is sold separately as an accessory.