General Specifications
Cable Type Distribution Construction Type Non­armored Construction Materials
Fiber Type Solution LazrSPEED® 550, 50 µm multimode fiber (OM4) Total Fiber Count 12 Fiber Type LazrSPEED® 550, 50 µm multimode fiber (OM4) Fiber Type, quantity 12 Jacket Color Black Jacket UV Resistance UV stabilized Dimensions
Cable Weight 33.0 lb/kft
|
49.0 kg/km Diameter Over Jacket 7.20 mm | 0.28 in Physical Specifications
Minimum Bend Radius, loaded 10.8 cm | 4.3 in Minimum Bend Radius, unloaded 7.2 cm | 2.8 in Tensile Load, long term, maximum 120 lbf
|
Tensile Load, short term, maximum 400 lbf
|
Vertical Rise, maximum 500.0 m
534 N 1780 N |
1640.4 ft ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 3
May 2, 2016
Product Specifications
760006650 | Z
760006650 | Z--012
012--DS
DS--5K
5K--FSUBK
Flame Test Specifications
Flame Test Listing NEC OFNR­LS (ETL) and c(ETL) Flame Test Method IEC 60332­3
|
IEC 60754­2
|
IEC 61034­2
|
IEEE 383
|
UL 1666
|
UL 1685 Environmental Specifications
Environmental Space Low Smoke Zero Halogen (LSZH)
Installation Temperature ­30 °C to +60 °C (­22 °F to +140 °F) |
Riser Operating Temperature ­40 °C to +70 °C (­40 °F to +158 °F) Storage Temperature ­40 °C to +75 °C (­40 °F to +167 °F) Mechanical Test Specifications
Compression 126 lb/in | 22 N/mm Compression Test Method FOTP­41
Flex 100 cycles Flex Test Method FOTP­104
Impact 4.34 ft lb
|
5.88 N­m Impact Test Method FOTP­25
|
IEC 60794­1 E4 Strain See long and short term tensile loads Strain Test Method FOTP­33
Twist 10 cycles Twist Test Method FOTP­85
Water Penentration 24 h Water Penentration Test Method FOTP­82
|
IEC 60794­1 E3 |
IEC 60794­1 E6 |
IEC 60794­1 E1 |
IEC 60794­1 E7 |
IEC 60794­1 F5 Environmental Test Specifications
Cable Freeze Test Method IEC 60794­1 F15 Heat Age ­40 °C to +85 °C (­40 °F to +185 °F) Heat Age Test Method IEC 60794­1 F9 Low High Bend ­40 °C to +70 °C (­40 °F to +158 °F) Low High Bend Test Method FOTP­37
Temperature Cycle ­40 °C to +70 °C (­40 °F to +158 °F) Temperature Cycle Test Method FOTP­3
|
|
IEC 60794­1 E11 IEC 60794­1 F1 Qualification Specifications
Cable Qualification Standards ANSI/ICEA S­104­696 | EN 187105
penetration) | Telcordia GR­409 |
Telcordia GR­20 (water Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2008
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 3
May 2, 2016
Product Specifications
760006650 | Z
760006650 | Z--012
012--DS
DS--5K
5K--FSUBK
Included Products
CS­5K­TB (Product Component—not orderable) — LazrSPEED® 550 OM4 Bend­Insensitive Multimode Fiber ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 3 of 3
May 2, 2016
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement