large field displays for pulse sensors (Hz)
www.nokeval.com
[email protected]
Nokeval
Yrittäjäkatu 12
37100 Nokia
Tel. 358-3-342 4800
Fax. 358-3-342 2066
575F, 1000F, 1100F and 1800F-2051
Large field displays for pulse sensors (Hz)
• Input frequency range 0,0001 Hz .. 5 kHz
• Sensors: NPN, PNP, Namur, Closing contact
or Pickup
• 1 to 6 digits on the display
• Digit sizes 57, 100 and 180 mm
• Galvanically isolated output 0/4..20 mA, 0..5/10 V
• Two alarm relays
• Pulse output for a cumulative counter
• Serial output RS-232 or RS-485
• Sensor supply 24 VDC
• Power supply 85..240 VAC or 24 VDC
1000F
575F
57 mm
5 digits
1100F
1800F
100 mm
6 digits
180 mm
1-5 digits
100 mm
4 digits
The field display series 2051 is designed for pulse sensors,
whose frequency will be measured, for applications where a
readability of 20 to 100 metres is required. The inputs are
NPN- , PNP -, Namur -sensors, closing contact or a pickupsensor. Selection of the sensor type and display scaling is
easy with the configuration keys and a 6-digit minidisplay
inside the case.
and RS-232. Optional cards can easily be added on afterwards
as well.
The input frequency range 0,0001Hz ..5 kHz is exceptionally
wide starting with extremely low frequencies. The display is
scaleable on the whole display range, e.g. 0-1,23 Hz can
correspond to the range 0-5000 on the display. Output is freely
scaleable on the basis of the display, e.g. 4-20 mA. The
measuring method applied for low frequencies is to measure
the time interval between two incoming pulses and for higher
frequencies to measure the frequency. The display also
provides a power supply of 24 VDC for a sensor.
Separate passwords can be set for access to the
configuration menu and alarms. Case protection rating is
IP65. The displays can also be used outdoors if exposure
to direct sun light is prevented by using a sun cover.
The alarm relay card (or I/O -card) may also be used as an
output for a pulse divider. The pulse divider transmits a pulse
for instance to an external counter when the pulse rate set in
the divider is reached (e.g. 1 pulse/ 1000 litres).
Large field displays can easily be modified for other sensor
types by only changing the input card for frequency, pulse or
serial bus inputs.
Readability of displays:
The display has two optional card slots: one for output 0/4-20
mA, 0-5/10V, and the other for alarms or serial output RS-485
Digit height
57 mm
100 mm
180 mm
Distance
20..30 m
40..50 m
ca. 100 m
Modular large field display 2051
Pulse sensor
24V supply
to sensor
3600
Display
Power supply 85..240VAC
or 24 VDC
Configuration
Output signals as an option:
Pulse output to the counter
(a cumulative counter)
Adjustable
pulse divider
Sensors:
NPN-, PNP- transistors
Namur (1..3 mA)
Pick-up
Closing contact
DAC
Alarm relay, 230V, 2A
Output 0/4..20 mA,
or 0-5/10V
Serial output RS-232
or RS-485
A minidisplay and configuration keys inside the case
Technical specification:
Input frequency range:
Display scaling:
Decimal point:
Updating time of display:
Sensors:
Sensor supply:
Measuring method:
Accuracy:
0,0001..5 kHz
on the whole display range
selectable
1..2 incoming pulses
NPN, PNP, Namur, pick-up
or closing contact
input pulse 0 = <1V, 1 = 5..32 V
24 VDC ±5 %, max. 40 mA,
isolated from power supply
measuring the time interval
between incoming pulses
0,01 % of span
General:
Input filter
Configuration
Terminals
Operating temperature
Power supply
Front panel rating
Weight
Types:
575F5-2051
Digit size 57 mm, 5 digits, red LED
Dark grey plastic enclosure, IP65
Digit size 100 mm, 4 digits, red LED
Black steel enclosure, IP65
Digit size 100 mm, 6 digits, red LED
Black steel enclosure, IP65
Digit size 180 mm, 1-5 digits, red LED
Black steel enclosure, IP65
x = number of digits, please specify
in your order
1000F4-2051
Output signal (optional):
Output 0..20 mA, 4..20 mA, max. load 1000 ohm.,
Voltage output 0-10V (max. load 5 mA)
Galvanic isolation from input and power supply (test voltage
2500 V, 1min.) Scaling programmable.
DAC 12 bits, accuracy 0,05 % of span
1100F6-2051
Serial output (optional):
RS-232 or RS-485 only for reading measurement values
Baud rate: 300...19200 baud
How to order:
Alarms (optional):
Two alarm levels adjustable via keys inside the case. Choice of
direction for relay function.
Relay contacts max. 230 VAC, 2A (2000-REL2)
An alternative to the pulse output.
Pulse output (optional):
Divider range
1..64000
Output pulse width
1..100 ms
I/O card
max. 60 V, 0,5 A
An alternative to the alarm relay for frequencies > 1 Hz.
digital, freely adjustable
keys and a minidisplay inside the case
removable, wire 2,5 mm²
-35..+50 °C
85..240 VAC or 24 VDC ± 15 %
IP65
575F: 3 kg, 1000F: 5 kg, 1100F: 8 kg,
1800F: 18 kg
1800Fx-2051
1000F4-2051-OUT-REL2-230VAC
Model
Number of digits
Input card 2051
Output card
Alarm card
Power supply
85..230VAC or 24VDC
Optional cards (2 options possible at a time):
Output card
2000-OUT
Alarm card, 2 relays
2000-REL2
I/O card (4 I/O-lines)
2000-I/O
Serial output RS-232/485
2000-RS
(When ordering a field display, the "2000" of the cards is left out.)
Connections:
Input
NPN-sensor
Slot A
6
5
4
0V 3
NPN 2
1
NPN-sensor
Pulse
5..24V
Slot B
6
5
4
3
2
1
Relay 2
Relay 1
7 8 9
Slot C
+
Card slot A for input
Card slots B and C for optional cards.
+
PNP-sensor
Slot A
Alarm relays
6
0..10V
5
Com
4 + 0..20mA
3
2
1
Slot A
24 VDC (max 40 mA)
6
5
4
0V 3
PNP 2
1
Output
+
6
5
4
3
2
1
Connect the wire only if
the display provides
the sensor supply
Pickup-sensor
Closing contact
PNP-sensor
6
5
4
0 3
Input 2
1
Pulse
5..24V
+24 VDC (max 150 mA)
Slot A
Pulse
5..24V
Closing contact
Pick-up sensor
6
Pick-up 5
4
0V 3
2
1
mV -signal (sinusoidal)
>100mV from magnetic
pick-up sensor
Slot A
281, 500, 670 1045
Dimensions (mm):
96,120,
130, 210
281, 455, 625, 1025
118,147,
210, 330
13,188,250, 375
Dimensions shown in the order:
575F, 1000F, 1100F, 1800F
1000F-1800F metal enclosure
575F plastic enclosure
Power supply
85..240 VAC
or 24 VDC
Glands: 2 x PG 11
301, 482, 650, 1030
151002