- Industrial & lab equipment
- Electrical equipment & supplies
- Circuit protection
- Surge protectors
- User manual
advertisement
▼
Scroll to page 2
SECONDARY SURGE ARRESTER “LIGHTNING ARRESTER” AG2401 & AG2401C For 120/240 VAC Single phase applications Also called 120/240 VAC Split phase For installation in Category “C”, “B” and “A” locations Service Entrance, branch panel and individual equipment applications LISTED OWHX 94X1 Parallel installation Multi-Mode protection Line - to - Ground Line - to - Line NEMA 4 polycarbonate plastic enclosure CERTIFIED LR38268 ½” nipple wire entry UV resistant 18", 12-gauge color coded leads Mounting Bracket Option (AG1BRKT) UL Listed to Lightning Protective Device 2.50” OWHX - Listing Number 94X1 2.50” CSA Certified Mounting Bracket Listing Number LR38268 Two year product warranty 1.38” Features and Applications: 0.938” 2.105” 0.188” The AG2401(C) is a Metal Oxide Varistor (MOV) based hardwired Lightning Protective 1.273” 1.56” device that is UL listed as a Secondary Surge Arrester, Category OWHX. These 1.00” HEX devices, commonly called Lightning Arresters, have been tested according to the ANSI/IEEE Standards C62.11 and C62.34. 1/ 2 - 14 NPSM THRD .7718 - .7769 PD & Secondary Surge Arresters are designed to .0813 - .8230 OD protect electrical equipment from the damaging effects of transient surges caused by lightning, utility switching, electric motor cycling, insulation arcing and various other large or sudden changes in electric current flow. The AG2401 is a single phase, two-pole arrester designed to protect single or split phase 120 volt or 120/240 volt electrical systems. Installation of the arrester can be made indoors or outdoors. Secondary Surge Arresters may be installed at the meter can or on the service entrance. Installation is allowed on the line side or the load side of the main disconnect of the service. Arresters may also be installed at an individual piece of equipment. The AG2401 housing is molded from weather and UV resistant polycarbonate which complies with the UL Standard for strength and flame resistance. All electrical connections in the AG Series are imbedded in a UL recognized epoxy to seal and protect them from moisture and corrosion. A partial list of applications that the AG Series is recommended for includes building electric service entrances, garages, street lights, traffic control lights and controllers, parking lot lights, electric motors for irrigation and farm applications,water and sewage lift stations. Performance Characteristics: MODEL SERVICE VOLTAGE POLES LEADS & LENGTH AG2401 120 / 240 2 3 - 18” AG2401C (“C” indicates clamshell Package) 12 gauge WIRE CONFIGURATION ACTUAL CLAMPING VOLTAGE (line to ground) 1,500 A 5,000 A 10,000 A L1, L2, GND/N Specifications: 490 980 1410 Wiring Diagrams: TECHNOLOGY: Parallel Metal Oxide Varistors CONFIGURATION: Each line to ground/neutral MAXIMUM LINE VOLTAGE: 150 volts AC line to ground ENCLOSURE: Weatherproof and UV resistant NEMA 4 molded polycarbonate. ENCAPSULATION: UL component recognized epoxy potting compound. UL Flame class 94V-0; Relative Temperature Index: Electric - 90, Mechanical - 90. MOUNTING: 1/2” x 20 threaded nipple. MOUNTING BRACKET: Right angle aluminum racket (Optional). Order AG1BRKT. WIRING: 18” of 12 gauge stranded copper wire is preconnected for each phase, neutral and ground. Wires exit the enclosure through the ½” nipple. WIRE COLOR CODE: Black - phase leads, White - ground/neutral lead. WEIGHT: 0.5 pounds, 0.8 pounds in carton. AGENCY LISTINGS: UL: OWHX - Listing No. 94X1 CSA: File No. LR38068 AMBIENT OPERATING TEMPERATURE: - 40 to + 85 OC (- 40 to + 185 OF). Line BLACK 120 v BLACK Ground WHITE Line 120 v BLACK Neutral 120 v BLACK Ground WHITE 0v Line BLACK 240 v Line BLACK 120 v Ground WHITE Suggested Specifications: The Secondary Surge Arrester(commonly known as a lightning arrester) shall be listed by Underwriters Laboratories (OWHX), ANSI/IEEE C62.11 for Category ‘C’ locations. The arrester shall provide protection between each phase conductor and ground. The Maximum Continuous Operating Voltage (MCOV) shall be a minimum of 150 volts AC between phase and ground. The Secondary Surge Arrester shall employ parallel MOV’s and provide protection from Category ‘C’ level transient surges as defined in ANSI/IEEE C62.11, C62.34, C62.41.1 and C62.41.2 without degradation of components. The arrester housing shall be constructed of UV resistant polycarbonate or material of equal strength and UV resistance. All electrical connections shall be sealed in a UL component recognized epoxy to exclude moisture, dirt and corrosion. The encapsulation shall have a minimum UL Flame Class rating of 94V-0. A one-half inch threaded nipple and locknut shall be provided. Leads shall be a minimum of twelve gauge and eighteen inches in length. When subjected to a 8 x 20 µS test impulse, the Peak Clamping Voltage shall be no greater than 490 volts for 1500 Amps, 980 volts for 5,000 Amps or 1,410 volts for 10,000 Amps (@ 4 x 10 µS). The arrester shall carry a two year warranty and be manufactured by a company who has engaged in the manufacture of such products for a minimum of five years. WARRANTY AND LIMITATION OF LIABILITY If within two (2) years from the date of purchase, this Secondary Surge Arrester fails due to defect in material or workmanship, Intermatic Incorporated will repair or replace it free of charge. The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping; (b) units which have been subject to unauthorized repair, opened, taken apart; (c) units not used in accordance with directions. Some states do not allow a limitation of damages, so the foregoing limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary, from state to state. This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) obtaining a Returned Authorization from the Intermatic Service Center at 815-675-7000. Contact the company or refer to the warranty sheet enclosed with each product for complete warranty details. INTERMATIC INCORPORATED SPRING GROVE, ILLINOIS 60081 www.intermatic.com © 2004 300AG10107
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project