Dot Hill Assured SAN 4000 Series Data Sheet
AssuredSAN™
4000 Series
SMART, SIMPLE STORAGE
for 2K, 4K, HD, and 3D Workflows
Scalable Performance
SimulCache™ - Low latency cache mirroring
Data rates up to 8Gb/sec. FC or 6Gb/sec. SAS
Up to 7 expansion units per system
Support for SAS, Nearline SAS, SSDs
Max 192 drives - 4520, 4720, 96 - 4530, 4730
Built in Redundancy
Dual RAID controller
Redundant, hot swap components
RAID 0, 1, 3, 5, 6, 10, 50
Certifications and Virtualization
Citrix, Microsoft, VMware certified
VAAI connector supported
Green Features
EcoStor™ battery-free cache backup
Drive-spin-down
RoHS-6 and WEEE compliant
Rugged Chassis
NEBS Level 3 Compliant
MIL STD 810G Compliant ( Storage Requirements)
European Telco Compliant
Dot Hill’s AssuredSAN™ Solutions offer a smart, simple approach to
storage management. The AssuredSAN™ Solutions combine high performance and high capacity storage with the ease of the RAIDar management GUI which provides a complete set of features and tools to
ensure easy storage administration.
In common with all AssuredSAN storage arrays, the 4000 Series boasts
99.999% availability due to stringent design standards, testing, and diagnostics.
Applications
The AssuredSAN 4000 Series sets a new storage standard for postproduction workflows. Offering 5200 megabytes per second sequential
reads and 2800 megabytes per second sequential writes, this Series
is ideal for video editing, broadcast, and telecommunications capture.
The 4000 Series is a shared storage system that works with shared file
systems like StorNext and Xsan to easily support multiple simultaneous
streams of 2K, 4K, HD and 3D content, without dropping frames.
Similarly, the 4000 system has the high performance and low latency
characteristics to meet data capture requirements for modern telecommunications digital networks and broadcast applications.
Ideal applications for the 4000 Series include onset acquisition, video
editing, finishing, rendering, streaming, broadcast, and telecommunications capture.
The 4000 Series is capable of 99.999% availability. Certifications are
pending for VMware vSphere, Citrix XenServer, and Microsoft Hyper-V.
TM
AssuredSAN 4000
Environmentally Responsible
Utilizing Dot Hill’s patented EcoStor™ technology, these systems have
completely eliminated cache batteries, using instead super capacitors
and flash memory to provide infinite cache backup during a power loss,
while being environmentally friendly.
The AssuredSAN 4000 Series also features energy saving drive-spindown. With the addition of drive spin-down, mixed drive type support
and dual protocol interfaces, users can now combine both high performance primary volumes and secondary storage with different performance and energy usage profiles in the same physical unit.
Enhanced Performance
The storage systems leverage patented SimulCache™ technology that
instantly and simultaneously mirrors cache between RAID controllers,
leading to significant performance improvements over traditional implementations.
Storage Made Easy
AssuredSAN arrays are easy to configure and manage with RAIDar 2.0,
our intuitive web based interface which provides storage setup and
monitoring without the need for host based software. RAIDar 2.0 saves
time with configuration and installation wizards, and schedulers.
• Easy to set up
• Configuration, Installation Wizards simplify management
• EcoStorTM eliminates routine battery maintenance
• Modular field replaceable power supplies, fans, and controllers
support
Warranty
AssuredSANs come with a three year standard hardware warranty, a
90 day software warranty, and Bronze level support, which provides expert 24X7 technical telephone support, access to online support and
the Customer Resource Center containing articles, product documentation, and firmware upgrades.
Gold and Platinum Support Programs
Gold and Platinum levels of support offer maximum responsiveness
anywhere in the world. These programs include options for same day
advance shipment, parts depot access, next business day, and 4-hour
onsite service. Extended hardware warranties and extended software
support packages are also available.
ordering information
Channel models described in this datasheet ship with the array, disk
drives, a rail kit, cables, Installation Guide, and Bronze support. They
come with AC Power.
A DC power option is available the driveless chassis.
For assistance, call 800-872-2783, ext 3575.
OEM Models
OEM models are available for volume OEM customers. For specific
information on models, availability, power supplies, contact our OEM
sales team.
models
Models - SAS 4520, Fibre Channel 4720
Models - SAS 4530, Fibre Channel 4730
With twenty four 2.5” Drives
With twelve 3.5” Drives
Drives per array
Max capacity per chassis
up to 24
24TB
Drives per array
Max capacity per chassis
up to 12
36TB
PHYSICAL
Depth (excluding cables)
Height
Width
Chassis weight
w / drives
20.46 Inches / 51.9 cm
3.5 Inches / 8.9 cm
17.6 Inches / 44.7 cm
36.4 lb / 16.5 kg
51.8 lb / 23.5 kg
PHYSICAL
Depth (excluding cables)
Height
Width
Chassis weight
w / drives
20.57 Inches / 52.25 cm
3.43 Inches / 8.71 cm
8.99 Inches / 48.24 cm
58.2 lb / 26.9 kg
78.2 lb / 35.5 kg
TM
AssuredSAN 4000
Detailed Specifications
Features
HOSTS
External Ports
4 per controller/8 maximum
Fibre Channel
Host speed
Interface Type
8Gb Fibre Channel
FCP
SAS
Initiators
Interface Type
DRIVE SUPPORT
4520, 4720
4530, 4730
SAS, Nearline SAS, SSD
Nearline SAS
(1 RAID, 7 JBOD) 192 DRIVES
(1 RAID, 7 JBOD), 96 DRIVES
100-240VAC 50/60Hz
465W maximum continuous - 4530, 4730
400W maximum continuous - 4520, 4720
1488 BTUs/hour
Bronze Rated - high efficiency
82% @ 20% load
86% @ 80% load
85% @ 100% load
SAS 2.0 (Serial-attached SCSI)
SAS SFF8088
* For most current drive support information ,
visit http://www.dothill.com/storage-arrays/drive-options/
EXPANSION
4120
4130
POWER REQUIREMENTS - AC INPUT
Input Power Requirements
Max Input Power
Max Input Power
Heat Dissipation
POWER REQUIREMENTS - DC INPUT
Voltage
-39 to -72VDC, -48/-60V nominal
Max Input Power
500W maximum continuous
Heat Dissipation
1706 BTU/hour
TEMPERATURE AND HUMIDITY RANGES
Operating Temperature
41°F to 104°F (5°C to 40°C)
Shipping Temperature
-40°F to 158°F (-40°C to 70°C)
Note: Derate 2°C for every km, up to
3000 meters
Operating Humidity
10% to 90% RH @ 104°F (40°C), non-condensing
Non-Operating Humidity
Up to 93% RH @ 104°F (40°C), non-condensing
CERTIFICATIONS
Microsoft, VMware, Citrix
DECLARED ACOUSTIC NOISE LEVELS
Sound Power
LWAd=6,75 B
Sound Pressure
LpAm - 55dBA
HIGH-AVAILABILITY FEATURES
Redundant Hot-Swap Controllers
Redundant Hot-Swap Disk, Fans, Power
Dual Power Cords
Hot Standby Spare
Automatic Failover
Multi-Path Support
SHOCK AND VIBRATION
Shock, Operational
Shock, Non-Operational
Vibration, Operational
Vibration, Non-Operational
5G’s for 10 ms
15G 11ms, half sine
5Hz to 500Hz, 0.21Grms flat spectrum
3-365-3Hz, 1.22 Grms, z-axis, 0.85 Grms,
X&Y axis shaped spectrum
PROTOCOLS AND STANDARDS
IP (RFC, 894, 1092)
SCSI-2 and SCSI-3
SUPPORT
Software Warranty
Standard Hardware Warranty
Note: Dot Hill AssuredSAN disk arrays chassis, power supplies, and controllers support
NEBS, ETSI, and MIL-STD-810G shock and vibration standards. Hard disk drive selection
may alter ability to achieve full compliance with these specifications as HDD’s have
varying S&V performance characteristics.
90 days
3 years
REGULATORY
Safety
RAID
Levels Supported
0, 1, 3, 5, 6, 10 and 50
SYSTEM CONFIGURATION
Cache Memory
Virtual disks per System
Volumes per virtual disk
Volumes per System
Mirrored Cache
Super Capacitor Cache Backup
Cache Backup to Flash
4GB per controller
32
256
1024
Yes - SimulCache™
Yes
Yes - Non-volatile
MANAGEMENT
Interface Types
Protocols Supported
Management Consoles
Management Software
Remote Diagnostics
Non-disruptive Updates
Volume Expansion
10/100 Ethernet, Mini USB
SNMP, SSL, SSH, SMTP, SMI-S Provider,
HTTP(S)
WEB GUI, CLI
RAIDar 2.0
COMPLIANCE AND STANDARDS
NEBS Level 3, MIL SPEC 810G
IP (RFC, 894, 1092) SCSI-2 AND SCSI-3
UL 60950-1, 1st edition, 2007-10-31 (USA)
CAN/CSA-C22.2 No.60950-1-03,
1st Edition, 2006-7 (Canada)
EN 60950-1:2006 (European Union)
EC 60950-1:2001 (International)
EN 60950-1:2001 +A11:2004 (GS Mark,Germany)
CCC Mark (power supply only, China PRC)
Electromagnetic Compatibility
Emissions
CFR 47 Part 15 Subpart B Class A (U.S.A.)
ICES-003:2004 Class A (Canada)
EN 55022:2006 +A1:2007 Class A (EU)
EN 300 386 V1.4.1:2008 Class A (EU Telco)
AS/NZS CISPR 22:2009 Class A (Australia, New Zealand)
VCCI:2009-04 Class A (Japan)
GOST R 51318.22-99 Class A (Russia)
KN 22 Class A (S. Korea)
CNS 13438:2006 Class A (Taiwan)
Harmonics
Flicker
Immunity
RoHS and WEEE
Country Approvals
EN61000-3-2:2006 (EU)
EN 61000-3-3:1995 +A1:2001+A2:2005 (EU)
EN 55024:1998 +A1:2001+A2:2003 (EU)
EN 300 386 V1.4.1:2008 (EUTelco)
GOST R 51318.24-99 (Russia)
KN 24 (S. Korea)
RoHS-6/6 Compliance, China RoHS, WEEE
United States, Canada, European Union (EU),
Australia/New Zealand, Japan, China (PRC) ,
Russia, Mexico, South Africa, Germany, South Korea, Taiwan
© 2012 Copyright Dot Hill Systems Corporation. All rights reserved. Dot Hill
Systems Corp., Dot Hill, the Dot Hill logo, and AssuredSAN are trademarks
or registered trademarks of Dot Hill Systems. All other trademarks are the
property of their respective companies in the United States and/or other
countries. 8.15.12
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement