Ideal Logic Combi Boiler Spec Sheet

Ideal Logic Combi Boiler Spec Sheet
LOGIC+ COMBI.
24
30
35
HIGH EFFICIENCY COMBINATION BOILERS
The Logic+ range has become renowned for its reliability thanks to
industry leading development and proven components such as the
Grundfos pump and Kromschroder PCB which in turn helped the range
win the Queen’s Award for Excellence in Innovation 2013.
LOGIC+ COMBI
+ Preheat function
+ 75mm deep translucent condensate siphon
+ Plain text operation and diagnostics display
+ Fully modulating operation to low outputs
+ Automatic bypass
RELIABLE
+ Energy Saving Trust recommended
+ 7 year parts and labour warranty*
+ Boiler frost protection
+ Built-in filling loop
EASY TO INSTALL
+ Compact cupboard fit
+ Door to optional timers includes user instructions
+ Fast fix telescopic horizontal flue
+ Wide range of additional flueing options
+ Low lift weight (33kg)
+ Preformed copper tails
+ Pre-wired mains lead (2m) & spare fuses included
+ PRV wall outlet pipe included
+ Universal condensate connection
+ Stand-off kit including piping
+ Compatible with a range of additional controls inc.
weather compensation and OpenTherm controls
+ LPG conversion kit available for 30 kW boilers
Winner of Household Boiler of the Year category.
Survey of 11,941 people by TNS.
Ideal Boilers
PO Box 103, National Avenue
Kingston Upon Hull
East Yorkshire, HU5 4JN
T: 01482 492251
[email protected]
WWW.IDEALBOILERS.COM
* Terms and conditions apply, please visit www.idealboilers.com for full details.
LOGIC+ COMBI
CLEARANCES & DIMENSIONS.
2.5
from case
2.5
395
Logic+
combi
278
165
Flue
terminal
700
100*
400
Note: The minimum front clearance when built-in to a cupboard is 5mm from the cupboard door but 450mm overall clearance with the cupboard
door open is required for servicing. *Bottom clearance after installation can be reduced to 5mm. However, 100mm is required for servicing.
FLUE LENGTHS.
Logic
heat
Max horizontal*
2.5
from case
2.5
+COMBI 30
8m 278
278
9m
395
Max vertical*
Powered
+COMBI 24
7.5m
165**
22m
vertical†
Available Kits High Level Flue Outlet Kit
+COMBI 35
6m
Direct
rear
flue
terminal
Flue
* Each 90° elbow used is at the expense of 1000mm of straight flue run, and each 45° elbow is used at the
expense of 600mm of straight flue run.
† Typical combined primary and secondary length. See installation instructions for more details. Note: The Flue Deflector Kit is used at the expense
terminal
of 1000mm of straight flue run.
TECHNICAL SPECIFICATIONS.
700
+COMBI 24
+COMBI 30
Height
700
Width
395
Depth
+COMBI 35
278
100*
Weight
37.7
37.8
38
32.7
32.8
33
CH output (kW) min/max @ 70°C
4.8 - 24.2
6.1 - 24.2
7.1 - 24.2
CH output (kW) min/max @ 40°C
5.1 - 25.6
6.4 - 25.6
7.5 - 25.6
24.2
30.3
35.3
400
Max installation weight (Kg)
DHW output (kW) max
2.535°C rise
DHW flow rate l/min.
Logic+
system
SEDBUK rating (2005) %
SEDBUK rating (2009) %
2.5
from case
9.9
91
165
89.0
NOx classification
12.4
395
91.1
14.5
278
89.0
91
88.9
CLASS 5
Adjustable to LPG
No
700
Yes
Flue No
terminal