Datenblatt EOP-SH
Laser Safety (Interlock) Shutter / X-RAY Shutter
EOP-SH-10-xx
1
FEATURES AND ADVANTAGES
















Integrated return spring
Model SH-10: 0.5" (13mm) aperture
Model SH-20: 1" (25mm) aperture, larger optional
Small size
Low cost
Simple to operate
High reliability, long life
STANDARD, CUSTOM and OEM safety shutters
STANDARD or CUSTOM blades
Jumps to "OFF" position with a power failure
5V, 12V, 15V, or 24V dc operation
Simple drive circuit for TTL input commands
Special pricing for OEM applications.
RoHS compliant
Patented technology
15msec Response Time
The SH-10 laser safety shutter consists of a blade mounted on a rotary solenoid with a limited
rotation angle. When the shutter is powered, the blade moves to an "ON" position and clears the path
for a laser beam. When the power is turned off, the return spring of the shutter moves the blade to
an "OFF" position and blocks the laser beam.
The standard blade material is 0.01" thick anodized aluminum. To meet laser specifications and for
uses like plasma or X-ray other materials and thickness are used.
THE SHUTTER IS IN THE "CLOSE" POSITION WHEN THERE IS NO CURRENT.
SPECIFICATIONS for the standard SH-10 laser safety shutter:







APERTURE SIZE: 0.5 inch dia; 0.42 inch dia for the boxed version.
POWER REQUIREMENTS:
o For the 5V laser safety shutter: 5V dc, 700 mA.
o For the 12V laser safety shutter: 12V dc, 300 mA.
o For the 24V laser safety shutter: 24V dc, 160 mA.
RESPONSE TIME: 15 mSec
RETURN SPRING TORQUE: 0.0055 to 0.009 Nm
EXPECTED LIFE:
o SH-10: 2 million cycles minimum
o SH-10-L: 50 million cycles minimum
SHUTTER DIMENSIONS: See CAD DRAWINGS
MAX. OPERATING TEMPERATURE: 75 deg C
We offer the following models (custom and standard) for the SH-10 laser safety shutter:












SH-10 Shutter comes with two studs for mounting and allows horizontal and vertical
mounting, 2 million cycles minimum.
SH-10-L Shutter comes with two studs for mounting and allows horizontal and vertical
mounting, 50 million cycles min.
SH-10-M Shutter comes with a mounting plate and allows horizontal and vertical mounting, 2
million cycles minimum.
SH-10-M-L Shutter comes with a mounting plate and allows horizontal and vertical
mounting, 50 million cycles minimum.
SH-10-MP Shutter can be mounted directly to an optical table, 2 million cycles minimum.
SH-10-MP-L Shutter can be mounted directly to an optical table, 50 million cycles minimum.
SH-10-B Shutter is boxed with a 0.42" dia through hole for laser light, 2 million cycles
minimum.
SH-10-B-L Shutter is boxed with a 0.42" dia through hole for laser light, 50 million cycles
minimum.
SH-10-PI Shutter has a position indicator to indicate the position of the blade, 2 million
cycles minimum.
SH-10-PI-L Shutter with a position indicator, 50 million cycles minimum.
SH-10-PI-B Shutter with a position indicator, 2 million cycles minimum. The shutter is
boxed, with a cutout for laser light.
SH-10-PI-B-L Shutter with a position indicator, 50 million cycles minimum. The shutter is
boxed, with a cutout for laser light.
2
M= Mount
MP= Mounting plate (to optical table)
L= Long life (50 million cycles min.)
B= The shutter is boxed, with a cutout for laser light
PI= Position indicator to indicate the position of the blade
The SH-10-PI Laser safety shutter incorporates two magnetic switches (sensors) that are a position
indicator to identify the position of the blade.
When the blade is in the "CLOSE" position one of the magnetic switches is normally closed and the
other is normally open. When the blade moves to the "OPEN" position the normally closed switch
becomes normally open and the normally open becomes normally closed. A three pin MOLEX
connector (P/N 22-03-2031) is used for the output of the position indicator.
THE SH-10-PI WITH THE DSH-10 DRIVER
The SH-10-PI IN THE "CLOSE" POSITION
Damage threshold: The standard blade is 0.01 inch thick black anodized aluminum, which
withstands 100 mW/mm² with a limit of 2 W of total power. We also offer solutions that meet laser
specifications, different wavelengths and more powerful laser beams. We offer a variety of materials
and thicknesses suitable for laser light, X-Ray and plasma, from VIS to FIR applications.
Please call to discuss your specific application.
You can also indicate the most suitable material for your application and supply your own mirrors,
gratings or other attachments.
The standard blade material for the SH-10 is 0.01 inch thick black anodized aluminum.
The standard blade material for the SH-20 is 0.02 inch thick black anodized aluminum.
3
We also offer the following blade solutions:

Bare aluminum blades
- 1mm thick aluminum blades
- 3mm thick aluminum blades

Clear anodized blades

Reflective blades, polished Nickel plating. You need to collect the energy into an energy
dump.

Tantalum blades

Gold plated blades. You need to collect the energy into an energy dump.

Mirrors, enhanced aluminum coated, epoxied onto the blade. You need to collect the energy
into an energy dump.

Mirrors, gold coated, epoxied onto the blade. You need to collect the energy into an energy
dump.

Mirror, silver coated, epoxied onto the blade. You need to collect the energy into an energy
dump
DRIVERS AND WAYS TO ACTIVATE THE LASER SAFETY SHUTTERS:
You can activate the laser safety shutter by applying the appropriate voltage: 5V to the SH-10-5, 12V
or 15V to the SH-10-12 and 24V to the SH-10-24.
We can supply you with schematics to build your own driver. When ordering a shutter without a
driver, please indicate one of the operating voltages: 5V, 12V or 15V, or 24V.
The DSH-10 DRIVER operates the SH-10 Laser Safety Shutter. The DSH-10 driver includes a three
position control switch. In the "OPEN" position, the shutter is continuously open. In the middle
position, the shutter is continuously closed. In the "TTL" position, an external TTL signal controls the
shutter. A high or open circuit at the TTL input sets the shutter in the closed position. A low or short
to ground at the TTL signal sets the shutter in the open position.
The following driver models that enable the user to control the shutter with a TTL signal
are available:

DSH-10-110 or DSH-10-220, a cased driver 5.3" x 5.3" x 2" operating from a line voltage
of 110Vac or 220Vac (please specify DSH-10-110 or DSH-10-220).

DSH-10-110/220, a cased driver 5.3" x 5.3" x 2" with a selector switch for operating from a
line voltage of 110Vac or 220Vac.

DSH-10-110-BNC or DSH-10-220-BNC, a cased driver 5.3" x 5.3" x 2" operating from a
line voltage of 110Vac or 220Vac (please specify DSH-10-110 or DSH-10-220) with a BNC
connector for TTL input.

DSH-10-5-PC, this is a PC board level driver for the SH-10-5 shutter that needs 5Vdc and
12Vdc (200mA).

DSH-10-TIMER-S, this is a preset timer to open the laser safety shutter for a specific time
from the range of 0.1sec to 10 minutes. Used only with the SH-10-24.

DSH-10-TIMER-L, this is a preset timer to open the laser safety shutter for a specific time
from the range of 0.1min to 10 hours. Used only with the SH-10-24.
4

DSH-20 driver can drive two SH-10 shutters simultaneously, open and close both shutters at
the same time.
The following models of this driver are available:
o
DSH-20-110 or DSH-20-220. This is a cased driver 5.3" x 5.3" x 2" operating from
a line voltage of 110Vac or 220Vac (please specify DSH-20-110 or DSH-20-220).
o
DSH-20-110-BNC or DSH-20-220-BNC, a cased driver 5.3" x 5.3" x 2" operating
from a line voltage of 110Vac or 220Vac (please specify DSH-20-110 or DSH-20-220)
with a BNC connector for TTL input.
o
DSH-20-110/220, a cased driver 5.3" x 5.3" x 2" with a selector switch for
operating from a line voltage of 110Vac or 220Vac.
o
DSH-20-110/220-BNC, a cased driver 5.3" x 5.3" x 2" with a selector switch for
operating from a line voltage of 110Vac or 220Vac with a BNC connector for TTL input
ORDERING INFORMATION:
1) REGARDING THE SH-10 LASER SAFETY SHUTTER:
o
o
o
o
o
o
o
POWER REQUIREMENTS: [SH-10-5, SH-10-12 or SH-10-24].
When ordering without a driver, please indicate one of the operating voltages: 5V, 12V or
15V, or 24V.
MOUNT: [-M]
MOUNTED TO AN OPTICAL TABLE: [-MP, M4, M6, 8-32, 1/4-20] 6-32 tapped holes are
standard.
BOXED: [-B, M4, M6, 8-32, 1/4-20] 6-32 tapped holes are standard.
EXPECTED LIFE: [-L] L=50M cycles, standard=2M cycles
BLADES SOLUTIONS:
- Standard blades
- Bare aluminum blades
- 1mm thick aluminum blades
- 3mm (1/8 inch) thick aluminum blades
- Clear anodized blades
- Reflective blades, polished Nickel.
- Tantalum blades
- Gold plated blades
- Mirrors, protected, enhanced aluminum
- Mirrors, protected, gold coated
- Mirror, protected, silver coated
POSITION INDICATOR: [-PI].
2) REGARDING THE LASER (SOURCE) INFORMATION:
o
BEAM SIZE [mm] ; BEAM POWER(Watt) ; WAVELENGTH[nm]
5
3) REGARDING THE DSH-10 DRIVERS:
-DSH-10-110V
-DSH-10-220V
-DSH-10-110-BNC
-DSH-10-220-BNC
-DSH-10-110/220
-DSH-10-110/220-BNC
-DSH-10-5-PC
-DSH-20-110
-DSH-20-220
TIMER: [-S,-L] S=a specific time from the range of 0.1 sec to 10 minutes, L=a specific time
from the range of 0.1 min to 10 hours.
-DSH-10-TIMER-S. Used only with the SH-10-24.
-DSH-10-TIMER-L. Used only with the SH-10-24.
NOTE: When ordering without a driver, please select one of the operating voltages: 5V, 12V
or 15V, or 24V.
Shutters are stock items.
Shutters are RoHS compliant.
Special pricing for OEM applications.
Examples:
Example 1: PART NO. SH-10-MP-L-TANT with DSH-10-110-BNC. This part number specifies
the model SH-10 laser safety shutter, long life (50 million cycles minimum), with a tantalum
blade and with mounting holes that fit an optical table and with a cased driver 5.3" x 5.3" x 2"
operating from a line voltage of 110Vac with a BNC connector for TTL input.
Example 2: PART NO. SH-10-B-12. This part number specifies the model SH-10 laser safety
shutter, boxed with a cutout for laser light and 12V operating voltage.
Example 3: PART NO. SH-10-PI-B-L-24-REF. This part number specifies the model SH-10-PI
laser safety shutter with a position indicator, boxed with a cutout for laser light, 24V operating
voltage, with a reflective blade (polished Nickel plating) and long life operation (50 million
cycles minimum).
6
SH-10-PI OUTLINE DRAWING:
7
WAYS TO ACTIVATE THE SH-10:
8
9