- Home
- Home security & automation
- Security cameras
- Arecont Vision
- MegaBall AV3146DN-3310-D-LG
- Installation manual
Arecont Vision MegaBall AV3146DN-3310-D-LG Installation manual
Add to my manuals15 Pages
Arecont Vision MegaBall is a versatile indoor surveillance camera that delivers exceptional image quality, flexibility, and ease of installation. With its robust features like 3-axis adjustability, vari-focal lens, and PoE connectivity, it's perfect for monitoring large areas, capturing wide-angle views, and ensuring optimal image clarity. The camera's ability to provide detailed images and cover blind spots makes it suitable for various applications, including retail stores, offices, warehouses, and public spaces.
advertisement
Arecont Vision MegaBall™ Installation Manual
0 | P a g e
Arecont Vision MegaBall™ Installation Manual
MegaBall™ Wall Mount Version (-W) Installation Manual
Inside the box:
A. Arecont Vision MegaBall™ camera with wall mount (indoor use only)
B. CD with AV100 software and user manuals (license key required for recording)
C. Mounting template
D. Pack of three (3) wood screws and three
(3) dry wall anchors
E. One double-sided hex key (fixed focal lens version only)
F. Security L-Key
3. Plug the Ethernet cable into the MegaBall™
PoE female RJ45 connector. (Image 2)
NOTE: If the camera will be powered via PoE,
please skip to step 5.
Not included but needed:
•
#1 Phillips head screwdriver
A B C
PoE RJ45
Digital In
Digital Out or Audio Out
Image 2
Auxiliary Power
D E F
4. If the camera will be powered by an AC 24V or DC 12-48V power supply, connect external power with pigtail cable connector.
NOTE 1: Ensure that the polarity of the DC input on the camera matches the way that the wires are installed in the connector shown in
Image 2.
NOTE 2: AC power does not have polarity.
Image 1
Mounting the Camera:
1. Remove the camera and hardware from the box.
2. Using the mounting template, prepare the mounting surface for camera installation.
5. Align the holes on the camera wall mount with the prepared holes on the mounting surface.
Attach the camera to the mounting surface with the wood screws or any other hardware suitable for the mounting surface.
1 | P a g e
Arecont Vision MegaBall™ Installation Manual
Adjusting the Tilt, Pan, Z-Axis (yaw):
6. To adjust the camera tilt, pan or z-axis (yaw), loosen the ring on the wall mount bracket as shown in Image 3 then adjust as necessary and retighten the ring. installation practices are not covered under warranty!
Adjusting the Focus, Iris and Field of View:
7. For the vari-focal model, adjust the focus, iris and field of view using the provided Security
L-Key (Image 1F) as shown in Image 5.
Bracket Ring
Image 3
NOTE : The 3-axis bracket allows 360° camera body rotation, 90° tilt and 360° bracket rotation for easy installation in any location. (Image 4)
90 °
360 °
360 °
Image 4
CAUTION: Adjusting the camera without loosening the bracket ring may result in scratches on the bracket joint. Incorrect
Zoom
Focus
Iris
Image 5
8. For the fixed-focal model, adjust the focus by loosening the two set screws on the front shell as shown in Image 6 using supplied double sided hex key (Image 1E). Adjust the lens adapter to focus the camera as shown in
Image 7. Retighten the set screws once focusing is complete.
Set Screws
Image 6 Image 7
2 | P a g e
Arecont Vision MegaBall™ Installation Manual
MegaBall™ Dome Version (-D) (-DA) Installation Manual
Inside the box:
A. Arecont Vision MegaBall™ camera with inceiling mount (indoor use only)
B. Surface mount (preassembled on dome)
C. Audio Bezel (-DA module only)
D. O-ring (preassembled on bezel)
E. Dome cover (Bubble)
F. CD with AV100 software and user manuals (license key required for recording)
G. One double-sided hex key (fixed focal lens version only)
H. Security L-Key
I. Pack of three (3) wood screws and three
(3) dry wall anchors
J. Mounting template
Mounting the Camera:
1. Remove the camera and hardware from the box.
2. Using the mounting template, prepare the mounting surface for camera installation.
3. Plug Ethernet cable into the MegaBall™ PoE female RJ45 connector. (Image 2)
NOTE: If the camera will be powered via PoE,
please skip to step 5.
PoE RJ45
Digital In
Not included but needed:
A
•
#1 Phillips head screwdriver
B C D E
Digital Out or Audio Out
F G H I
Image 1
J
Auxiliary Power
Image 2
4. If the camera will be powered by an AC 24V or
DC 12-48V power supply, connect auxiliary power to terminal block on pigtail cable connector.
NOTE 1: Ensure that the polarity of the DC input on the camera matches the way that the wires are installed in the connector shown in
Image 2.
NOTE 2: AC power does not have polarity.
3 | P a g e
Arecont Vision MegaBall™ Installation Manual
In-ceiling Mount Installation (Optional) 5. Using the provided Security L-key (Image
1F), loosen the three (3) screws securing the dome cover (Image 3). Remove the vandal resistant dome cover. NOTE: Do not remove
the screws from the dome cover.
7. Using the mounting template, cut a hole in the surface for mounting.
8. Insert the in-ceiling mount camera into the hole.
9. Tighten the “lever screws” until the flush mount is snug, as shown in Image 5. The
“Support Arm” will ride down the screw to compress the mounting surface. NOTE: Do not over-torque the lever screws.
Image 3
6. Loosen the three (3) machine screws (Image
4) and remove the in-ceiling mount camera from the surface mount housing. (Image 4)
Screws
Image 4
Lever
Screw
Support
Arm
Image 5
Surface mount installation
10. Align the holes in the surface mount with the prepared holes on the mounting surface with the wood screws or any optional hardware suitable for the mounting surface.
11. Attach the in-ceiling camera to the surface mount, using the three machine screws as shown on Image 4.
4 | P a g e
Arecont Vision MegaBall™ Installation Manual
Adjusting the Tilt, Pan, Z-Axis (Yaw): Adjusting the Focus, Iris and Field of View:
12. To adjust the camera tilt, pan or z-axis (yaw), loosen the 3 set screws on the in-ceiling mount as shown in Image 6. Then adjust as necessary and retighten the 3 set screws.
13. For the vari-focal model, adjust focus, iris and field of view using the provided Security L-Key
(Image 1H on Page 3) as shown in Image 8.
Set Screw
Image 6
NOTE : The 3-axis in-ceiling camera allows
360° camera body rotation, 90° tilt, and 360° camera sleeve rotation for easy installation in any location as shown in Image 7.
Camera Sleeve
Rotate 360
°
Tilt 90
°
Focus Zoom
Iris
Image 8
NOTE 1: Fully open the lens iris and close iris as necessary to get better sharpness and depth of field.
NOTE 2: Fully opening the lens iris under strong light condition may result in less sharpness and artificial color in Megaball™ WDR camera series as shown in Image 9 and 10.
Image 7
Camera Body
Rotate 360
°
Image 9: Fully open lens iris
5 | P a g e
Arecont Vision MegaBall™ Installation Manual
17. Attach the provided dome cover (Image 1D
on Page 3) to the bezel as shown in Image
14.
Image 10: Close lens iris as necessary
14. For the fixed-focal model, adjust the focus by loosening the two set screws on the front shell as shown in Image 11 using the supplied double sided hex key (Image 1G).
Drift Pin
Image 13
Image 11 Image 12
15. Adjust the lens adapter to focus the camera as shown in Image 12. Retighten the set screws once focusing is complete.
Dome Cover (Bubble) Installation (Optional):
16. Remove the O-ring (Image 1D on Page 3) from the bezel by pushing on the 4 drift pins on the back of bezel shown in Image 13.
Image 14
18. Remove the protective film from the bubble.
NOTE: Take precaution not to scratch the bubble.
19. Secure the dome cover to the camera using the provided Security L-Key (Image 1H on
Page 3)
6 | P a g e
Arecont Vision MegaBall™ Installation Manual
Audio Bezel Installation ( -DA models only):
20. If adding dome cover (Image 1E) on the bezel is necessary, follow Step 21-23 to replace installed bezel with provided audio bezel
(Image 1C) and get best audio quality.
21. Remove O-ring (Image 1D), screws and rubber cable from default bezel as shown in
Image 15.
23. Secure the dome cover to the camera using the provided Security L-Key (Image 1H) as shown in Image 17.
Default Bezel
O-ring
Rubber
Cable
Image 15
22. Install screws and dome bubble on the audio bezel as shown in Image 16.
Image 17
Note: If the dome cover is not required, keep using default bezel and make sure the microphone hole is not covered by the liner as shown on Image 18.
Microphone hole
Image 18
Image 16
Audio
Bezel
7 | P a g e
Arecont Vision MegaBall™ Installation Manual
Optional: Connecting Digital I/O and Audio Out:
24. To use the digital I/O, connect the digital I/O to the pigtail cable connector as shown in
Image 2.
NOTE: Table 1 shows the electrical characteristics and Table 2 shows cable color for digital I/O.
Electrical
Characteristics:
Input voltage (V)
(measured between
+ and – terminals)
ON
OFF
Min Max Camera
2.9 6.3
0 1.3
IR & DN
Versions
Output current (mA)
(measured between
+ and – terminals)
Applied Voltage
Rage: 0 - 80V
ON
OFF
-
-
50
0.1
DN version
Only
Table 1
NOTE: Both the input and the output are electrically isolated from the rest of the camera’s electrical circuitry via general-purpose photo couplers. The input is additionally protected with a serial 250 Ohm resistor and a debouncing circuit. Duration of any input signal should be at least 5ms to comply with the requirements of the debouncing circuit.
Yellow Digital IN +
Red Digital IN –
Green Digital OUT + / Audio Out +
Black Digital OUT - / Audio Out -
NOTE: The Audio Out will be only available for
Megaball Audio models (-A)
Table 2
Camera Installation:
25. Install the AV100 application manager
Software. (Image 19, found on the CD).
26. Run the AV100 application manager by double clicking on the icon shown below.
(Image 20, found on your desktop).
NOTE: you can download latest version
AV100 on website http://www.arecontvision.com/softwares.php
Image 19 Image 20
27. Select “Run” next to “Setup Cameras” from the AV100 application manager as shown in
Image 21 and wait for “Arecont Vision
Camera Installer” window to appear as shown in Image 22.
Image 21
28. Click “Mode” tab to select desired install mode on the Arecont Vision Camera Installer as shown in Image 22.
8 | P a g e
Arecont Vision MegaBall™ Installation Manual
NOTE 1: Basic Mode: software will automatically discover and change / assign IP address to match
PC subnet if they are not locked.
NOTE : Double click the camera model on the
Camera Installer as shown in Image 22 to access the camera web interface. See “AV Camera Web
Page User Manual” (found on the CD) for details on the web interface.
NOTE 2: Advanced Mode: software will automatically discover but allow manual update of the IP address. See “AV100 Installation Manual”
(found on the CD) for details on Advanced Mode.
NOTE3: User can verify camera model number and
FW version of all cameras as shown in Image 23.
Image 22
29. For basic mode, select “Install Cameras” on the Arecont Vision Camera Installer as shown in Image 22.
30. Confirm that all the cameras connected to the network switch appear in the upper window.
31. Repeat Step 29 if all of the cameras do not appear in the upper window.
CAUTION: If the software does not find a camera, the software utility may be blocked by the anti-virus or Windows
®
firewall. Before turning them off, please consult your IT manager.
Image 23
32. When all cameras are discovered and display
“Installed, online”, select “Save/Exit.” The
AV100 application main menu will appear.
33. From the “AV100 Application Manager” menu, select “Run” next to “Live video” to view live images.
NOTE: See the “AV100 Installation Manual”
(found on CD) for details on camera configurations.
9 | P a g e
Arecont Vision MegaBall™ Installation Manual
MegaBall Accessories (Sold Separately)
Wall Mount (D4S-WMT-B or D4S-WMT) Installation Instructions
Inside the box:
A. Wall mount ( Fits ¾” NPT Standard)
B. Pack of three (3) machine screws, four (4) wood screws and four (4) dry wall anchors
C. Mounting template
NOTE: D4S-WMT-B color is black and D4S-
WMT color is light grey.
Not included but needed:
•
#2 Phillips screw driver
Image 25
5. Run Ethernet cable through the wall mount
6. Attach wall mount to the wall using drywall screws or any optional hardware suitable for the mounting surface.
7. Connect Ethernet cable with Megaball pigtail cable as shown on Image 25
A
B
C
Image 24
1. Remove wall mount and hardware from the box.
2. Using the mounting template, prepare the mounting provisions for camera installation.
3. Attach surface mount (Image 1B on Page 3) to wall mount as shown in Image 25 using three machine screws provided.
Image 26
8. For installation of the camera, please reference “Mounting the Camera”.
10 | P a g e
Arecont Vision MegaBall™ Installation Manual
MegaBall Accessories (Sold Separately)
Pendant Mount (D4S-CMT-B or D4S-CMT) Installation Instructions
Inside the box: 3. Attach surface mount (Image 1B on Page 3) to pendant mount as shown in Image 28 using three machine screws provided.
A. Pendant Mount (Fits with ¾” NPT)
B. Pack of three (3) machine screws, three
(3) wood screws and three (3) dry wall anchors
C. Mounting template
NOTE: D4S-CMT-B color is black and D4S-
CMT color is light grey.
Not included but needed:
D. #2 Phillips screw driver
Image 28
4. Run Ethernet Cable through the Pendant
5. Attach Pendant to the ceiling using the three wood screws provided or any optional hardware suitable for the mounting surface.
6. Connect Ethernet cable with Megaball pigtail cable as shown on Image 28
B
A
C
Image 27
1. Remove pendant mount and hardware from the box.
2. Using the mounting template, prepare the mounting provisions for camera installation.
Image 29
6. For installation of the camera, please reference “Mounting the Camera”.
11 | P a g e
Arecont Vision MegaBall™ Installation Manual
MegaBall Accessories (Sold Separately)
Junction Box Adapter (SV-JBA) Installation Instruction
Inside the box:
A. Junction Box Adapter
B. Pack of four (4) machine screws
C. One double-sided hex key
D. Pack of four (4) wood screws and four (4) dry wall anchors
E. Mounting template
Not included but needed:
•
#2 Phillips screwdriver
•
Wall Mount, MD-WMT
•
¾” NPT Conduit (if necessary)
Image 31
A B C D E
Image 30
1. Remove junction box adapter and hardware from the box
2. Remove the conduit plug by first removing the socket set screw using the provided hex key (C) as shown on Image 31.
3. Attach the junction box adapter to the wall using drywall screws or any optional hardware suitable for the mounting surface.
Conduit hole
Image 32
4. Attach the wall mount to junction box adapter then attach cap to the wall mount as shown in
Image 32.
5. Connect ¾” NPT Conduit to the junction box adapter.
6. Run Ethernet cable and outside power cable (if necessary) through the Junction Box Adapter and Wall Mount.
7. For installation of the camera, please reference
“Mounting the Camera.”
12 | P a g e
Arecont Vision MegaBall™ Installation Manual
MegaBall Accessories (Sold Separately)
Electrical Box Adapter (SV-EBA) Installation Instructions
Inside the box: (Accessory Sold Separately)
A. Electrical Box Adapter
B. Pack of four (4) machine screws
Image 34-1 Single gang box
A
D4S-WMT
Bracket holes
Image 34-2 Double gang box
Image 33
Not included but needed:
•
#2 Phillips head screwdriver
•
Common electrical box, such as single gang box, double gang box, or square electrical boxes shown in Image 34-1~4.
1. Remove the electrical box adapter and hardware from the box.
2. Attach the wall mount bracket to the electrical box adapter.
3. Attach adapter to electrical box.
Image 34-3 Square box
Image 34-4 Square box
13 | P a g e
Arecont Vision MegaBall™ Installation Manual
R
1 | P a g e
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project