Series AM1SS-Z  1 Watt | DC-DC Converter Models
Click on Series name for product info on aimtec.com
Series AM1SS-Z
1 Watt | DC-DC Converter
FEATURES:
•
•
•
•
Models
Single output
Model
AM1SS-0505SZ
AM1SS-0512SZ
AM1SS-0515SZ
AM1SS-1205SZ
AM1SS-1212SZ
AM1SS-1215SZ
AM1SS-2405SZ
AM1SS-2412SZ
AM1SS-2415SZ
Input
Voltage
(V)
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
RoHS Compliant
4 Pin Sip Package
Low Ripple And Noise
High Efficiency up to 81%
Output
Voltage
(V)
Output
Current Max
(mA)
5
12
15
5
12
15
5
12
15
200
83
67
200
83
67
200
83
67
•
•
•
•
Isolation
(VDC)
1000
1000
1000
1000
1000
1000
1000
1000
1000
Operating Temperature -40oC to +85oC
Input / Output Isolation 1000 and 3000VDC
Pin Compatible with Multiple Manufacturers
Continuous Short Circuit Protection
Input Current
Full Load | No
Load (mA)
267
267
173
110
107
111
54
56
51
55
52
50
20
23
23
15
15
12
Max
Capacitive
Load (µF)
Efficiency
(%)
100
100
100
100
100
100
100
100
100
75
75
73
76
78
75
77
75
81
AM1SS-0505SH30Z
4.5-5.5
5
200
3000
267
55
100
75
AM1SS-0512SH30Z
4.5-5.5
12
83
3000
267
52
100
75
AM1SS-0515SH30Z
4.5-5.5
15
67
3000
173
50
100
73
AM1SS-1205SH30Z
10.8-13.2
5
200
3000
110
20
100
76
AM1SS-1212SH30Z
10.8-13.2
12
83
3000
107
23
100
78
AM1SS-1215SH30Z
10.8-13.2
15
67
3000
111
23
100
75
AM1SS-2405SH30Z
21.6-26.4
5
200
3000
54
15
100
77
AM1SS-2412SH30Z
21.6-26.4
12
83
3000
56
15
100
75
AM1SS-2415SH30Z
21.6-26.4
15
67
3000
51
12
100
81
NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Turn on Transient process time
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Input reflected Ripple current
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
www.aimtec.com
F 051e R12.C
Nominal
Typical
5
12
24
4.5-5.5
10.8-13.2
21.6-26.4
Capacitor
with 12µH
200
0-7
0-15
0-28
100
20
Conditions
Typical
5 Vin
12 Vin
24 Vin
60sec
Tel: +1 514 620 2722
1 of 4
VDC
25
ms
ms
ms
mA p-p
Typical
±3
Units
VDC
> 1000
10
Conditions
Maximum
Continuous
Rated
Units
1000 and 3000
VDC
MOhm
pF
Maximum
Units
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1SS-Z
1 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Capacitive load
Rising time
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
Auto-Recovery
±1.2
±10
±0.02
100
For 1% change of Vin
Load 20 – 100%
At 20MHz Bandwidth
50
Conditions
Typical
100% load
Full Load without Derating
80
Maximum
Units
% of Vin
%
%/oC
mV p-p
μF
ms
220
Maximum
-40to +85
-40 to +125
Free air convection
Units
KHz
o
C
o
C
o
C
100
95
Non-conductive black plastic UL94-VO
1.5
0.46 x 0.24 x 0.40 inches 11.68 x 6.00 x 10.15 mm
>1 121 000 hrs(MIL-HDBK -217F, Ground Benign, t=+25oC)
%
g
Safety Specifications
Standards
Safety
IEC 60950-1 (Designed to meet)
Pin Out SpecificationsDimensions
Pin
1
2
3
4
Single
- V Input
+V Input
- V Output
+V Output
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1SS-Z
1 Watt | DC-DC Converter
Typical Efficiency Example Charts
Eff %
AM1SS-0512SZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
20%
40%
60%
80%
100%
Loading %
Eff %
AM1SS-1205SZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
20%
40%
60%
80%
100%
Loading %
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1SS-Z
1 Watt | DC-DC Converter
Eff %
AM1SS-2412SZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
20%
40%
60%
80%
100%
Loading %
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF