p3rsrx
Prices as of April 15, 2015. Check Web site for most current prices.
Remote Slave Modules
P3-RS
P3-RX
Rack with CPU Module
(P3-550 only)
$449.00
$299.00
The P3-RS/P3-RX are high-performance
Remote Slave modules (for use with
P3-550 CPU-based systems only). Both
modules have several communications
ports which support USB Expansion I/O,
Ethernet Remote I/O and serial devices.
The P3-RS also includes a 4 line x 10
charactor LCD display and an additional
USB IN (type B) port for remote CPU
programming and monitoring.
Racks with P3-RS/P3-RX
Modules
Node
Node
11
P3-550
Node
Node 11
Stride Ethernet Switch
Node 2
Up to 16 Remote Slaves can be
connected to a single CPU for a remote
I/O network.
P3-RX
REMOTE SLAVE
P3-RS REMOTE SLAVE
PWR
RUN
Configure
each node
with unique
address.
Up to
Node 16
RXD TXD
233
2
LNK
-
23
23
EXP I/O OUT
RXD TXD RTS
LNK
456
456
SLAVE ADDRESS
X1
X10
X10
X10
44 556 6
RS-232
G
23
X1
X
1
78
901
4 5 6 456
78
901
78
78
01
EXP I/O OUT
REMOTE I/O
23
7
9019
SLAVE ADDRESS
X1
X10
7 88
9 90011
See Important
Information on
page 3 before
installation.
ACT
REMOTE I/O
CPU
+
RS-485
Add up to 16 Remote Base Groups using P3-RS or P3-RX Remote Slave modules and up to 32 GS Drives
on the Remote I/O Ethernet Network (P3-550 only).
SE-SW5U
Local Base Group
Remote Base Group
Remote Base Group
Add up to
4 bases to
each group
using P3-EX
expansion
modules
with USB
connections.
GS-EDRV100
Book 1 (14.2)
eP3-42
Productivity3000 Controllers
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Remote Slave Modules
Company
Information
Control Systems
Overview
Remote Slave Specifications (for P3-550
only)
Controller slot
Mounting Location
Display (P3-RS only)
LCD, 4x10 characters, backlit, LCD characters are 5x7
with a dot pitch of 0.45mm; 2.25mm x 3.15mm
Communications -
USB IN: (2.0, Type B) Programming, Monitoring, Debug
(P3-RS Only)
REMOTE I/O: (10/100Mbps Ethernet) 1 P3-550
EXP I/O OUT: (2.0, Type A, Proprietary) 4 P3-EX
Local Expansion Bases
RS-232: (RJ12, 1200-115.2k Baud) ASCII, Modbus
RS-485: (Removable Terminal Included,
1200-115.2k Baud) ASCII, Modbus
ax. Number of Ethernet
M
Remote I/O Bases
Max. Number of
Expansion I/O Bases
Max. Number of I/O per
CPU System
P3-RS/P3-RX Product Comparison
Item
P3-RS
P3-RX
LCD Display
USB Prog/Mon Port
Do-More T1H
PLC
Remote Port (in)
DirectLOGIC
PLCs Overview
USB Local Expansion Port
DirectLOGIC
DL05/06
RS-232 RJ12 Port
RS-485 Port
DirectLOGIC
DL105
16
68 (4 per CPU, 4 per Remote Base)
DirectLOGIC
DL205
59,840 (CPU Base with 4 Expansion Bases plus 16
Remote Bases with 4 Expansion Bases per Remote,
with 11 64-point I/O modules per base)
DirectLOGIC
DL305
Operating Temperature
0° to 60°C (32° to 140°F)
Storage Temperature
-20° to 70°C (-4° to 158°F)
Humidity
5 to 95% (non-condensing)
Environmental Air
No corrosive gases permitted
Vibration
IEC60068-2-6 (Test Fc)
Shock
IEC60068-2-27 (Test Ea)
Heat Dissipation
4W
Enclosure Type
Agency Approvals
Open Equipment
UL508 file E157382, Canada & USA
UL1604 file E200031, Canada & USA
CE (EN61131-2*)
This equipment is suitable for use in Class 1,
Division 2, Groups A, B, C and D or non-hazardous
locations only.
Controller slot in a remote base in a Productivity3000
System
See the “EU Directive” topic in the Productivity3000
Help File. Information can also be obtained at:
www.productivitypac.com
260g (9 oz)
EU Directive
Weight
Do-More
PLCs Overview
Do-More H2
PLC
DirectLOGIC
DL405
General Specifications
Module Location
CLICK PLC
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
*Meets EMC and Safety requirements. See the Declaration of Conformity for details.
Appendix
Book 1
IMPORTANT!
Terms and
Conditions
Hot-Swapping Information
Note: This device cannot be Hot Swapped.
WARNING: Explosion hazard – Substitution of components may
impair suitability for Class I, Division 2.
NOTE: When using the P3-RX, you must use Productivity3000 software version 1.0.7.XX and firmware version 1.1.13.XX or later.
Book 1 (14.2)
www.automationdirect.com/productivity3000
Productivity3000 Controllers
eP3-43
Prices as of April 15, 2015. Check Web site for most current prices.
Remote Slave Modules
Front Panel
P3-RX
LCD
- Backlit screen
- 4 x 10 character
- User defined alarms/
messages
- PLC system alarms /
information
ACT
78
78
RS-232
RXD TXD
G
LNK
-
EXP I/O OUT
23
USB 2.0 (Type A) Port
Local expansion bases
(connect up to 4 expansion
bases per base group)
RXD TXD RTS
LNK
REMOTE I/O
Address Rotary Switch
Set the Remote I/O Slave
Address (1-99) using the
rotary switches.
456
456
456
CPU
456
RS-485 Serial Port
(TB Style)
- Modbus/ASCII
(master peripheral device
or multiple slave devices
using the same protocol)
Status Indicators
RUN
901
SLAVE ADDRESS
X1
X10
78
901
EXP I/O OUT
RS-232 Serial Port (RJ12)
- Modbus/ASCII
(master or slave)
peripheral device
PWR
10/100 MB Ethernet
connection to the
Remote I/O port on
the P3-550 CPU
901
901
Address Rotary Switch
Set the Remote I/O Slave
Address (1-99) using the
rotary switches.
78
23
10/100 Mbps Ethernet
connection to the
Remote I/O port on the
P3-550 CPU.
REMOTE I/O
Status Indicators
SLAVE ADDRESS
X1
X10
USB 2.0 (Type B) Port
- Programming
- Online monitoring
P3-RX
REMOTE SLAVE
23
P3-RS REMOTE SLAVE
23
P3-RS
+
RS-485
RS-232 Serial Port (RJ12)
- Modbus/ASCII
(master or slave)
peripheral device
RS-485 Serial Port
(TB Style)
- Modbus/ASCII
(master peripheral device
or multiple slave devices)
using the same protocol
USB 2.0 (Type A) Port
Local expansion bases
(connect up to 4 expansion
bases per base group)
LCD (P3-RS only)
Status Indicators
The P3-RS incorporates a 4 line x 10
character LCD for system errors and
information or for displaying userdefined messages.
RS Status Indicators
LCD characters are 5x7 with a dot
pitch of 0.45mm; 2.25mm x 3.15mm.
PWR
Green LED is backlit when
power is on
RUN
Green LED is backlit when CPU
is in RUN mode
CPU
Red LED is backlit during power
on reset, power down, or watchdog time-out.




P3-RS
For user-defined messages, the display is configured using
the Productivity Suite Programming Software. An LCD Page
instruction allows the user to program text into user-defined
tags and display the messages based on the ladder execution.
See the Productivity Suite Programming Software Help
Files for complete details.
Book 1 (14.2)
eP3-44
Productivity3000 Controllers
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Remote Slave Modules
Company
Information
Control Systems
Overview
CLICK PLC
Setting the Remote
Slave Address
Do-More
PLCs Overview
ACT
RS-232
RXD TXD
G
LNK
EXP I/O OUT
RXD TXD RTS
LNK
456
456
SLAVE ADDRESS
X1
X10
456
456
456
X10
X10
X1
X
1
456
456
456
23
SLAVE ADDRESS
X1
X10
REMOTE I/O
SLAVE ADDRES
SLAVE
AD
ADDRESS
DRESS
S
X1
X10
23
EXP I/O OUT
78
23
23
23
X10
X1
0
78
23
23
901
78
REMOTE I/O
901
78
See Important
Information on
page 3 before
installation.
78
901
78
CPU
23
78
DirectLOGIC
DL05/06
RUN
78
901
456
PWR
901
X1
X
1
DirectLOGIC
PLCs Overview
901
901
456
P3-RS REMOTE SLAVE
901
901
78
IMPORTANT NOTES:
• The factory setting of 00 is not a
valid address.
See Important
78
on
• Address selection mustInformation
be 3set
prior
to
page
before
installation.
power-up.
• Slave addresses are only read on
power-up.
• If there are duplicate slave addresses
on the same network, a critical error will
occur.
Do-More T1H
PLC
P3-RX
REMOTE SLAVE
901
For example, to set a remote slave
address to 21, turn the X10 arrow
until it points at number 2 and the X1
arrow until it points at number 1.
Do-More H2
PLC
23
Each Remote Slave must have a unique
address between 1 and 99. The address
is set using the two rotary switches located
on the face of the module, X10 for setting
the tens units and X1 for setting the ones
unit.
+
RS-485
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
23
Universal
Field I/O
It is also necessary to configure the
remote addresses using the Productivity
Suite Programming Software.
Software
1
C-More
HMI
C-More Micro
HMI
This can be done automatically by first
going online with a Productivity3000
system that has slave modules installed,
go to Hardware Configuration and
select the Read Configuration (1) button.
The CPU will automatically read the
addresses of the remote slaves and add
them to the configuration.
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
Book 1 (14.2)
www.automationdirect.com/productivity3000
Productivity3000 Controllers
eP3-45
Prices as of April 15, 2015. Check Web site for most current prices.
Remote Slave Modules
P3-RS REMOTE SLAVE
P3-RS REMOTE SLAVE
Port Specifications
REMOTE I/O
23
EXP I/O OUT
456
456
SLAVE ADDRESS
RESS
X1
X10
456
23
456
78
901
EXP I/O OUT
78
901
78
901
SLAVE ADDRESS
X1
X10
78
901
USB IN Port (P3-RS only)
P3-RX
23
REMOTE I/O
P3-RS
23
The P3-RS/P3-RX has several communications ports. The following pages have
specifications and pin-out diagrams for
these ports.
Standard USB 2.0 (Type B) Slave input
for remote CPU programming and online
monitoring, with built-in surge protection.
USB IN Specifications
Description
Transfer Rate
Port Status LED
Cables
Standard USB 2.0 (Type B) Slave input for remote CPU
programming and online monitoring, with built-in surge
protection. Not compatible with older full speed USB devices.
4
2
480 Mbps
Green LED is illuminated when LINK is established to
programming software.
USB Type A to USB Type B:
1
Pin #
3
Mating face of USB
type B female
Signal
1
+5
2
–Data
3
+Data
4
GND
3 ft. cable part # USB-CBL-AB3
6 ft. cable part # USB-CBL-AB6
10 ft. cable part # USB-CBL-AB10
15 ft. cable part # USB-CBL-AB15
Remote I/O Port
Remote I/O Port Specifications
Description
Transfer Rate
Proprietary transformer isolated Ethernet Port with built-in surge
protection for connection to CPU Remote I/O Master port.
10/100 Mbps
Port Status
LEDs
Green LED is illuminated when network LINK is established.
Yellow LED backlit when port is active (ACT).
Cables
Use a Patch (straight-through) cable when a switch or hub is
used.
Use a Crossover cable when a switch or hub is not used.
(Cables available at automationdirect.com)
Crossover Cable
TD+ 1
TD– 2
RD+ 3
4
5
RD– 6
7
8
RJ45
TD+ 1
TD– 2
RD+ 3
4
5
RD– 6
7
8
RJ45
OR/WHT
OR
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
GRN/WHT
GRN
OR/WHT
BLU
BLU/WHT
OR
BRN/WHT
BRN
Patch (Straight-through) Cable
OR/WHT
OR
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
OR/WHT
OR
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
1
2
3
4
5
6
7
8
TD+
TD–
RD+
8
RD–
1
REMOTE I/O
Isolated Ethernet Port with built-in surge
protection for connection to P3-550 CPU
Remote I/O Master port.
RJ45
1
2
3
4
5
6
7
8
TD+
TD–
RD+
RD–
RJ45
12345678
8-pin RJ45 Connector
(8P8C)
Book 1 (14.2)
eP3-46
Productivity3000 Controllers
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Remote Slave Modules
P3-RS REMOTE SLAVE
P3-RS REMOTE SLAVE
Company
Information
Control Systems
Overview
CLICK PLC
EXP I/O OUT Port
Do-More
PLCs Overview
2
1
Mating face of USB
type A female
EXP I/O OUT
456
DirectLOGIC
PLCs Overview
78
456
SLAVE ADDRESS
RESS
X10
X1
456
456
REMOTE I/O
REMOTE I/O
SLAVE ADDRESS
X1
X10
EXP I/O OUT
23
3
78
DirectLOGIC
DL05/06
23
4
23
Green LED is illuminated when LINK is established to connected device
USB Type A to USB Type B. The P3-EX Expansion Module
includes a 6 foot USB cable, part number P3-EX-CBL6.
Do-More H2
PLC
Do-More T1H
PLC
901
Port Status
LED
Cables
78
P3-RX
901
Transfer Rate
78
901
Proprietary USB 2.0 (Type A) Master output for connection
with up to four P3-EX local expansion bases, with built-in surge
protection.
480 Mbps
901
EXP I/O OUT Specifications
Description
P3-RS
23
USB 2.0 (Type A) Master output for
connection to up to four P3-EX local
expansion bases, with built-in surge
protection.
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
Pin #
Signal
1
Reset
2
– Data
3
+ Data
4
GND
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
RS-232 Serial Port
Software
Non-isolated RS-232 DTE port connects
the P3-RS/P3-RX as a Modbus or ASCII
master or slave to a peripheral device.
RS-232 Specifications
Description
Non-isolated RS-232 DTE port connects the P3-RS/P3-RX
as a Modbus or ASCII master or slave to a peripheral device.
Includes ESD and built-in surge protection.
Data Rates
Selectable,1200, 2400, 9600, 19200, 33600, 38400, 57600,
and 115200 bps.
+5V Cable Power 210mA maximum at 5V, +/- 5%. Limited by self-resetting
Source
current limiting device. Reverse polarity protected.
TXD
RS-232 Transmit output
RXD
RTS
RS-232 Receive input
Handshaking output for modem control.
GND
Maximum Output
Load (TXD/RTS)
Minimum Output
Voltage Swing
Output Short
Circuit Protection
Port Status LED
Cable Options
Logic ground
C-More
HMI
C-More Micro
HMI
Pin #
6
1
6-pin RJ12 Female
Modular Connector
Signal
1
GND
Logic Ground
2
+5V
210 mA Maximum
3
RXD
RS-232 Input
4
TXD
RS-232 Output
5
RTS
RS-232 Output
6
GND
Logic Ground
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
3KV, 1,000pf
+/-5V
+/-15mA
Green LED is illuminated when active for TXD, RXD and RTS
FA-ISOCON for converting RS-232 to isolated RS-485
Book 1 (14.2)
www.automationdirect.com/productivity3000
ViewMarq
Industrial
Marquees
Productivity3000 Controllers
eP3-47
Prices as of April 15, 2015. Check Web site for most current prices.
Remote Slave Modules
P3-RS REMOTE SLAVE
P3-RS REMOTE SLAVE
RS-485 Serial Port
Maximum Common
Mode Voltage
Port Status LED
REMOTE I/O
EXP I/O OUT
456
456
SLAVE ADDRESS
RESS
X1
X10
456
456
Pin #
+/- 250mA, thermal shut-down protection
+/-8KV per IEC1000-4-2
Signal
G
GND
–
TXD-/RXD-
+
TXD+/RXD+
Removable connector included.
Spare connectors available
(part no. P3-RS485CON).
+/-2KV per IEC1000-4-4.
1.5V with 60V load
Logic high input state if inputs are unconnected
-7.5V to 12.5V.
Green LED is illuminated when active for TXD and RXD
Terminal Block Specifications
Number of Positions
3
Pitch
Wire Range
L19827-1000
Screw Driver Width
5 MM
28-12AWG Solid Conductor
30-12AWG Stranded Conductor
1/8 inch (3.175mm) maximum
Belden 9841 equivalent
Screw Size
M2.5
Screw Torque
4.5 Lb-in
L19827-100
Cable Options
SLAVE ADDRESS
X1
X10
REMOTE I/O
50 transceivers, 19KV each, 60V termination
EXP I/O OUT
19KV
Maximum load
Output Short Circuit
Protection
Electrostatic Discharge
Protection
Electrical Fast
Transient Protection
Minimum Differential
Output Voltage
Fail safe inputs
23
Logic ground
Input Impedance
78
23
RS-485 transceiver low
GND
78
901
TXD-/RXD-
P3-RX
901
TXD+/RXD+
Selectable, 1200, 2400, 9600, 19200, 33600, 38400,
57600, and 115200 bps.
RS-485 transceiver high
Data Rates
78
901
Non-isolated RS-485 port connects the P3-RS/P3-RX
as a Modbus or ASCII master or slave to a peripheral
device. Includes ESD/EFT protection and automatic
echo cancellation when transmitter is active.
78
901
RS-485 Specifications
Description
P3-RS
23
Removable
connector
included.
Spare connectors available (part no.
P3-RS485CON).
23
Non-isolated RS-485 port connects the
P3-RS/P3-RX as a Modbus or ASCII master
or slave to a peripheral device.
L19827-500
Installation Procedure
Step One:
Locate the two sockets
next to the power supply;
the module will be inserted into this location.
Step Two:
Insert at a 45° angle
into the notch
located at the top of
the base and rotate
down until seated.
Step Three:
Snap retaining tab into the locked position.
WARNING: Explosion hazard – Do not connect
or disconnect connectors or operate switches
while circuit is live unless the area is known to
be non-hazardous. Do not hot swap.
Book 1 (14.2)
eP3-48
Productivity3000 Controllers
1-800-633-0405
Was this manual useful for you? yes no