60 High Static Pressure Fan 9HV type
60
High Static Pressure Fan
9HV type
■ Features
High Static Pressure
The maximum static pressure increased by approximately 92%
compared with our conventional DC fan, while maintaining equivalent
maximum airflow performance. *
It is an ideal cooling solution especially for densely-packed equipment.
Suitable for 1.5 to 2U Devices
Measuring 60 mm square, this new fan is ideal for 1.5 to 2U sized
equipment.
* : Our conventional DC fan is 60 x 60 x 38 mm “San Ace 60” 9GA type,
Model No. 9GA0612P1S03.
60×60×38 mm
■ Specifications
The following nos. have PWM controls, pulse sensors. For ribless, append "1" to the model no.
PWM
Expected
Operating
Rated voltage Operating
Rated current Rated input Rated speed Max. airflow Max. static pressure SPL
life
temperature
voltage range duty cycle
-1]
3 / min] [CFM]
[min
[V]
[A]
[W]
[m
[Pa]
[inchH
2O] [dB(A)]
(Note
1,2)
[V]
[ ℃]
[h]
[%]
Model no.
9HV0612P1J001
12
10.8 to 12.6
100
2.7
20
0.17
32.4
21,700
1.88
66.4
1,750
7.00
68
5,300
0.43
15.2
102
0.41
34
2.04
40,000 / 60℃
-20 to +70 (70,000 / 40℃)
Note1: PWM frequency: 25 kHz Note2: Fan does not rotate when PWM duty cycle is 0%.
Please inquire as the availability of these options depends on the model. ⇒
Available options: Without Sensor
Lock sensor
■ Common Specifications
□ Material ・・・・・・・・・・・・・・・・・・・・・・・・・・ Frame, Impeller: Plastics (Flammability: UL94V-0)
□ Expected life ・・・・・・・・・・・・・・・・・・・・・ Refer to specifications
(L10: Survival rate: 90% at 60℃, rated voltage, and continuously run in a free air state)
□ Motor protection system ・・・・・・・・・・ Current blocking function and reverse polarity protection
□ Dielectric strength ・・・・・・・・・・・・・・・・ 50 / 60 Hz, 500 VAC, 1 minute (between lead conductor and frame)
□ Sound pressure level (SPL) ・・・・・・・・ Expressed as the value at 1 m from air inlet side
□ Operating temperature ・・・・・・・・・・・・ Refer to specifications (Non-condensing)
□ Storage temperature ・・・・・・・・・・・・・・ -30℃ to +70℃ (Non-condensing)
+ Red ○
- Black Sensor: Yellow Control: Brown
□ Lead wire ・・・・・・・・・・・・・・・・・・・・・・・・ ○
□ Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 135 g
■ PWM Duty
- Speed Characteristics Example
■ Airflow - Static Pressure Characteristics
(inch H2O)
7
・ Operating voltage range
(Pa)
1,800
12 VDC
(inch H2O)
7
1,600
5
4
3
6
PWM duty cycle
100%
1,400
→ Static pressure
→ Static pressure
6
1,200
1,000
800
600
2
1
0
400
0
0.4
0
10
0.8
20
4
3
30
1.2
40
1.6
50
→ Airflow
60
2.0 (m3 / min)
70 (CFM)
PWM duty cycle 100%
1,600
12 V / 12.6 V
0
(min-1)
22,000
Voltage: 12 VDC
PWM frequency: 25 kHz
21,700 min-1
20,000
18,000
1,400
10.8 V
1,200
16,000
1,000
800
600
2
1
20%
200
5
(Pa)
1,800
Speed
・ PWM duty cycle
14,000
12,000
10,000
8,000
400
6,000
200
4,000
0
0.4
0
10
0.8
20
30
1.2
40
1.6
50
→ Airflow
60
2.0 (m3 / min)
70 (CFM)
0
PWM duty cycle
100 (%)
■ PWM Input Signal Example
Input signal waveform
■ Example of Connection Schematic
VIH=4.75 V to 5.25 V
DC fan input voltage
VIL=0 V to 0.4 V
VIH
+
○
Inside of DC fan
PWM duty cycle (%) = T1 ×100
T
PWM frequency 25 (kHz) = 1
T
10kΩ
Source current (Isource) : 1 mA max. at control voltage 0 V
VIL
Control
Sink current (Isink) : 1 mA max. at control voltage 5.25 V
PWM input signal
Control terminal voltage: 5.25 V max. (Open circuit)
T1
T
22Ω
20kΩ
Isource
Isink
When the control lead wire is open,
the fan speed is the same as the one
at a PWM duty cycle of 100%.
Either TTL input, open collector or open drain can be used
for PWM control input signal.
-
○
■ Specifications for Pulse Sensors
Output circuit: Open collector
Inside of DC fan
+
○
Output waveform (Need pull-up resistor)
In case of steady running
VCE=+13.8 V max.
Ic=5 mA max. [VOL=VCE (SAT) =0.6 V max.]
(One revolution)
T0
Sensor Pull-up resistor
Ic
T2
T1 to 4≒ (1/4) T0=60/4N (sec)
T3
T4
N=Fan speed (min-1)
VOH
VOL
Sensor output
(VCE)
-
○
T1
Pull-up voltage
T1 to 4≒ (1/4) T0
0V
■ Dimensions (unit: mm)
4-φ4.5±0.3
Mounting hole
50±0.3
60±0.5
+50
300 0
(10)
Lead wire
AWG24
UL1430
4±0.3
50±0.3
4±0.3
38±0.5
60±0.5
Rotating direction
Airflow direction
■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm)
4-φ4.5
29.7
50 ±0.3
59
62
.7
Inlet side, Outlet side
59
50±0.3
29.7
Notice
●Please read the "Safety Precautions" on our website before using the product.
●The products shown in this catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited.
●For protecting fan bearings against electrolytic corrosion near strong electromagnetic noise sources,
we provide effective countermeasures such as Electrolytic Corrosion Proof Fans and EMC guards. Contact us for details.
3-33-1 Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan TEL: +81 3 5927 1020
http://www.sanyodenki.com
The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies.
“San Ace” is a trademark of SANYO DENKI CO.,LTD.
Specifications are subject to change without notice.
CATALOG No. C1057B003 ‘16.3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement