D4-UAR100R FT 54614101

D4-UAR100R FT 54614101
ZODIAC DATA SYSTEMS GMBH
HS615-3510
Technical Specification
HEIM DATaRec 4 UAR100R Rugged
General
The HEIM DATaRec® 4 UAR100R Rugged module supports 8 dual
redundant MIL-STD-1553 input channels. The module is designed
to meet harsh environmental like in mobile and FTI applications.
The DATaRec® 4 Rugged modules can be linked together to a multi
channel data acquisition system via HeimLink interface
The HEIM DATaRec® 4 represents leading edge technology.
Weight
Communication
Display, button, LED
Functions
Supported dataformat
UAR100
8 Mil-STD-1553 input channels
Number of channels
Operation mode
Input signal
Signal level direct coupled
Transformer coupled
Operation mode
Total bus recording
Selected bus recording
Selected message recording
Bus load identification
Time stamping
Time resolution
Cooling
Power consumption
Power source
Power input range
Connector
Dimensions
(overall)
8 dual-redundant MIL-STD-1553B
busses
record, no E to E
MIL-STD-1553B
1.15 Vpp - 20 Vpp
0,86 Vpp - 14 Vpp
bus monitor only
yes
yes
no
bus load computed and displayed
each packet time stamped in
IRIG106 CH10 mode
100 ns
conduction cooled
7 watts typical
normal operation
max. 10 watts heating during cold
start phase
via HeimLink interface
17 - 28 V DC
50-pin D-Sub male
standard HEIM DATaRec 4 rugged
housing
70.8 x 189 x 100 mm (w x h x d)
each channel provides an IRIG
independent 106 chapter
10 data stream
Environmental specifications
Vibration
Acceleration
Shock
Operating Temp.
Storage Temp.
Humidity
ZODIAC Data Systems GmbH
1200 g typical
HeimLink interface
yes
Page 1 of 2
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice.
7.7 grms
MIL-STD-810F,
Procedure 514.5,
Category 24 (General use)
8.92 grms
RTCA/DO-160F, Section 8,
Category S, Test curve D
15 g
MIL-STD-810F, Method 513.5
Procedure II
(manned aerospace vehicles)
20 g / 11 ms
MIL-STD-810F, Method 516.5
Procedure I
40 g / 11 ms
MIL-STD-810F, Method 516.5
Procedure V
-31°C1) - +71°C
MIL-STD-810F,
Method 501.4 and 502.4,
Procedure II
-55°C - +90°C
MIL-STD-810F,
Method 501.4 and 502.4,
Procedure I
0-95% relative, non-condensing
Document No.: 54614101
Technical Specification HEIM DATaRec® 4 UAR100R Rugged Module
Altitude
RFI
MIL-STD-810F, Method 507.4
0-21.000 m
MIL-STD-810F, Method 500.4
Procedure I, II,..
designed to MIL-STD-461F
Notes
Performance varies depending on the installation environment. The
shown values were measured using an appropriately designed test
system including the HEIM DATaRec® 4 power supplies under
nominal conditions of temperature, voltage, etc..
Performance is significantly influenced by storage medium type,
host computer performance and load, used acquisition software,
signal module configuration, power supplies and cabling.
The DATaRec® 4 Rugged series supports the record functionality.
For replay purposes a wide range of DATaRec® 4 replay modules /
systems are available.
1)
2)
special start-up procedure required
for operation in industrial environment (according to DIN EN
61326) earthing of the module and / or shielded cable is
necessary to prevent influences by external electromagnetic
distortions.
ZODIAC Data Systems GmbH
Friedrich-Ebert-Strasse / TechnologiePark – D-51429 Bergisch Gladbach
Tel.: +49 2204 84 41 00 – Fax: +49 2204 84 41 99
[email protected] – http://www.zodiac-data-systems.com
ZODIAC Data Systems GmbH
Page 2 of 2
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice.
Document No.: 54614101