i100 Lock

i100 Lock
Pgs 302-335
8/10/04
6:11 PM
Page 316
i100 Lock
Safety interlocks
i100 Lock
The i100 series safety interlocks with
actuator, allow to it to distinguish a guard
guard lock are designed to prevent the
that has been released from one that
operator from opening the guard before
has been released and opened.
the machine hazard motion has stopped.
The i100 series has been designed with
Thanks
to
the
anodized
die-cast
a mechanical lock that can be released
aluminum alloy enclosure, the high
by applying voltage to the electrical coil
performance of this safety interlock is
(i100 M) or with an electrical lock that
suitable for the most demanding heavy-
can be released by removing voltage
duty industrial environments. Two coil
from the electrical coil (i100 E).
status LED indicators and the availability
of auxiliary release, allow the operator to
The high retention force (1000 N) and
the availability of safety and alert
contacts associated with the coil and the
316
SAFETY CATALOG 2004
program and monitor operating conditions.
Pgs 302-335
8/10/04
6:11 PM
Page 317
i100 Lock
Drawings
Actuating head oriented to the left and
electrical connection PG/M20
mechanism for
manual unlock
Actuating head oriented to the right
and electrical connection PG/M20
Locking Devices
Metal Housing
mechanism for
manual unlock
SAFETY CATALOG 2004
317
Pgs 302-335
8/10/04
6:11 PM
Page 318
i100 Lock
Actuating head oriented to the left and
electrical connection SR 11
mechanism for
manual unlock
Actuating head oriented to the right
and electrical connection SR 11
mechanism for
manual unlock
318
SAFETY CATALOG 2004
Pgs 302-335
8/10/04
6:11 PM
Page 319
i100 Lock
Technical specifications
Housing material
Housing color
Environmental protection to IEC 60 529
Mounting position
Mechanical service life
Ambient temperature
Approach speed (max.)
Actuating force
Retaining force in locked condition
Switching elements
Contact elements
Switching principle
Rated insulation voltage
Utilization category IEC 947-5-1
Switching voltage (min.)
Switching current (min.) at 24 V
Contact material
Connection type
Cable cross-section (max.)
Short-circuit protection
Weight
Solenoid
Solenoid operating voltage
On time
Connected load
i100 Lock
die-cast silver alloy
black
IP 67
optional
2 X 106 switching cycles
-25…80° C
20m/min
35 N
1000 N
2 X 11
1 NO + 1 NC
slow action
Vi = 250 V=˜
AC-15 Ue 230 le 6 A/ DC 13 Ve 24 Ule 6 A
12 v
10 mA
silver alloy, gold-plated
screw terminal
1.5 mm2
slow 10 A, fast 20 A
1.07 Kg
24/110/230 V=˜
100%
7W
Switching elements
11 gold-plated,
slow action, 1 NC
forced opening
positive + 1 NO
OPERATING VOLTAGE OF SOLENOID
110 V AC -15…+10%
230 V AC -15…+10%
Locking Devices
Metal Housing
24 V DC -15…+10%
SAFETY CATALOG 2004
319
Pgs 302-335
8/10/04
6:11 PM
Page 320
i100 Lock
System connection
24 V AC/DC
110 V AC/DC
230 V AC/DC
Voltage control
± 10%
± 10%
± 10%
GN
RD
Insertion direction
The head can be rotated
by unscrewing the four
D
clamping screws.
E (C)
A
B
LED function
The LED allows operating check of safety interlock:
Green: safety circuit closed
Red: key unblocked, safety circuit open
Installation note
The safety switch and actuator must be assembled for installation purposes. The
actuator must be permanently secured to the safety device such that it can no be
detached, e.g., with unscrewable screws, rivets or welding. The safety switch should not
be used as a mechanical stop plate.
Auxiliary locking device
In case of failure, the mechanical release can be used to unlock safety devices with a
mechanical lock.
The mechanical release mechanism may be sealed to prevent tampering.
320
SAFETY CATALOG 2004
Pgs 302-335
8/10/04
6:11 PM
Page 321
i100 Lock
Product selection table
Model
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
i 100
Block
Mechanical Electrical
E
E
M
E
M
E
M
E
M
E
M
E
M
E
M
M
E
M
E
E
M
E
M
E
M
E
Action
right
left
L
R
R
L
L
R
R
L
L
L
L
R
R
R
L
L
L
L
R
R
R
L
L
R
R
Solenoid voltage
Switching
24 V DC 110 V AC 230 V AC Element
024
024
230
230
230
230
024
024
024
024
110
110
110
110
0
11
0
11
0
11
2
11
2
11
0
11
2
11
2
11
1
11
1
11
1
11
1
11
Connections
PG 13.5 SR 11
M 20
1
1
1
1
1
1
2
2
2
2
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
3
Part
number
6 012 122
6 012 118
6 012 123
6 012 124
6 012 119
6 012 120
6 012 127
6 012 128
6 012 125
6 012 126
6 021 907
6 021 908
6 021 909
6 021 910
6 022 595
6 022 591
6 022 592
6 022 593
6 022 594
6 022 596
6 022 597
6 022 598
6 022 599
6 022 600
6 022 601
6 022 602
We recommend contacting Customer Service for product selection.
Accessories: connectors and cable glands
Connector technical specifications
Housing material
Number of PINs
Nominal voltage
Protection class
Connection type
plastic
12 (11+PE)
50 V ~/=
IP 65
crimp contacts 0.5…1.5 mm2
SSR 11, connector
ASR 11, connector
Connector
Cable gland M16
Cable gland M20
Cable gland PG 13.5
straight
angled
for safety switch
Number of PIN
Part number
11+PE
11+PE
11+PE
6 020 757
6 020 758
6 020 759
5 309 163
5 309 163
5 305 811
Locking Devices
Metal Housing
Selection table
Type
We recommend contacting Customer Service for product selection.
SAFETY CATALOG 2004
321
Pgs 302-335
8/10/04
6:11 PM
Page 322
i100 Lock
Actuator for hinged door to left iE100-R1 - part number 5 306 498
.
Actuator for hinged door to right iE100-R2 - Part number 5 306 499
Lockout bar - Part number 5 603 534
322
SAFETY CATALOG 2004
Pgs 302-335
8/10/04
6:11 PM
Page 323
i100 Lock
Actuator for hinged door on bottom iE100-R3 - Part number 5 306 500
.
Actuator for hinged door on top iE100-R4 - part number 5 306 526