документацию FR11G Universal Compressor R134a 220
FR11G
Universal Compressor
R134a
220-240V 50Hz
General
Code number
103G6980
Approvals
EN 60335-2-34, CCC
Compressors on pallet
80
Application
Application
LBP/HBP
Frequency
Hz
50
60
Evaporating temperature
°C
-30 to 5
–
V
187 - 254
–
Voltage range
Max. condensing temperature continuous (short)
°C
60 (70)
–
Max. winding temperature continuous (short)
°C
125 (135)
–
Hz
50
60
Cooling requirements
Frequency
Application
LBP MBP HBP LBP MBP HBP
32°C
F2
F2
F2
–
–
–
38°C
F2
F2
F2
–
–
–
43°C
F2
F2
F2
–
–
–
Remarks on application: HBP at 198 - 254V 50Hz only.
S =Staticcoolingnormallysuficient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysuficent
–
= not applicable in this area
Motor
Motor type
RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST
A
10.0
Cut in Current, HST | LST
A
10.0
10.3
15.0
Resistance, main | start winding (25°C)
Ω
7.3
12.0
Design
Displacement
cm3
11.15
Oil quantity (type)
cm3
450 (polyolester)
Maximum refrigerant charge
Free gas volume in compressor
g
900
3
1350
kg
10.6
cm
Weight without electrical equipment
Dimensions
Height
mm A
196
B
191
B1
–
B2
Suction connector
Process connector
Discharge connector
Oil cooler connector
8.2 | 30°
material | comment
Cu-plated steel | Al cap
location/I.D. mm | angle D
6.2 | 30°
material | comment
Cu-plated steel | Al cap
location/I.D. mm | angle E
6.2 | 25°
material | comment
Cu-plated steel | Al cap
location/I.D. mm | angle F
–
material | comment
Connector tolerance
–
location/I.D. mm | angle C
I.D. mm
–
±0.09
Remarks:
Dec 2011
Manufactured by Secop for Danfoss - DEHC.ED.400.E2.02 / 520N1222
1/2
220V, 50Hz, fan cooling F2
EN 12900 Household (CECOMAF)
Evap. temp. in °C
-45
-40
-35
Capacity in W
-30
-25
-23.3
-20
-15
-10
-6.7
-5
0
5
115
170
191
233
307
395
463
501
628
780
Power cons. in W
165
202
215
240
278
317
343
357
400
445
Current cons. in A
1.52
1.59
1.63
1.69
1.81
1.95
2.05
2.10
2.26
2.42
COP in W/W
0.70
0.84
0.89
0.97
1.11
1.25
1.35
1.40
1.57
1.75
10
15
20
7.2
10
15
20
220V, 50Hz, fan cooling F2
ASHRAE LBP
Evap. temp. in °C
7.2
-45
-40
Capacity in W
-35
-30
-25
-23.3
-20
-15
-10
-6.7
-5
0
5
141
209
235
287
378
487
572
619
777
966
Power cons. in W
165
202
215
240
278
317
343
357
400
445
Current cons. in A
1.52
1.59
1.63
1.69
1.81
1.95
2.05
2.10
2.26
2.42
COP in W/W
0.86
1.04
1.09
1.20
1.36
1.54
1.67
1.73
1.94
2.17
Accessories for
PTC starting device
FR11G
Figure
6.3 mm spade connectors
4.8 mm spade connectors
a1
Code number
Test conditions
EN 12900/
CECOMAF
ASHRAE
103N0011
Condensing temperature
55°C
55°C
103N0018
Ambient temperature
32°C
32°C
Starting relay
6.3 mm spade connectors
a2
117U6010
Suction gas temperature
32°C
32°C
Start. capacitor 80 µF
6.3 mm spade connectors
c
117U5015
Liquid temperature
55°C
32°C
Cover
b
103N2010
Cord relief
d
103N1010
Mounting accessories
Protection screen for PTC
g
103N0476
Bolt joint for one comp.
Ø: 16 mm
118-1917
Bolt joint in quantities
Ø: 16 mm
118-1918
Snap-on in quantities
Ø: 16 mm
118-1919
Code number
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspeciicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2
Manufactured by Secop for Danfoss - DEHC.ED.400.E2.02 / 520N1222
Dec 2011
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement