VT76xxW Technical Sheet
PIR Ready VT7600W Series
WSHP Controller
For Commercial HVAC Applications
(Issue Date January 10th, 2012 – 028-6035 R0)
PRODUCT OVERVIEW
The new Viconics VT7600W Water Source Heat Pump Controller with
dedicated dehumidification sequences provides exceptional control of water
source heat pumps for commercial buildings. Common indoor air quality
issues such as mold, mildew, condensation, poor occupant comfort and
overall building health can be effectively resolved in an energy-efficient
manner using our new controller. Simple to install and commission, this wallmounted device monitors water temperature, as well as other points, that offer
added value without the additional costs related to more complex systems.
Designed for new construction and retrofit projects, the Viconics Water
Source Heat Pump Controllers dramatically decrease project delivery costs by
reducing installation, configuration and commissioning time. No complex software or tools are required to
customize functionality in order to meet your required applications. The Viconics water source heat pump
controller provides all the advanced features and monitoring functions required by most modern building
automation systems in one simple “thermostat like” enclosure.
The Viconics Water Source Heat Pump Controllers also feature an intuitive menu-driven, backlit LCD display that
guides users through the configuration steps, making the configuration process extremely simple. This menu is
used to configure parameters such as temperature, time events, system mode, fan mode and more.
When compared to traditional building automation controllers, the Viconics wall-mounted VT7600W Water
Source Heat Pump Controller with RH control for dehumidification provide building owners with unmatched
return on investment while maximizing profits for system integrators.
The additional following documentation is available on www.viconics.com
-
PIR application information and examples are available on document: APP-VT76-PIR-Guide-Exx
PIR cover installation information is available on document: PIR Cover Installation-Exx
Information on the BACnet models (VT76xxX5x00B), is available on document ITG-VT76xx-PIR-BAC-Exx
Information on the Wireless models (VT76xx0X5x00W), is available on documents: ITG-VWG-50-BAC-Exx and LIT-VWG-50-SETUP-Exx
MODELS AVAILABLE
APPLICATION
2 HEAT, 2 COOL
Model (with scheduling)
VT7652W5X00(X)
Model (without scheduling)
VT7600W5X00(X)
Ordering Information Notes:
- (X) model number represents available communication options: X=none for Network Ready, X=B for BACnet MS-TP, and X=W for Wireless
- Controllers can be ordered with a factory installed PIR cover. Please use (5500) extension instead of the (5000) only extension. Ex. VT7606B5500B.
- Controllers ordered without a PIR cover can be retrofitted with a separate PIR accessory cover afterwards when required
FEATURES & BENEFITS
FEATURES
BENEFITS
Built-in dehumidification strategies
Resolve common building issues such as mold, mildew and
condensation
Extra monitoring points provided
Provide better remote view of system performance
Open protocol allows for easy integration into any network
system
Allows the end user to choose the best network system based
on building requirements
Controllers are Network Ready and can be field retrofit
with optional communication modules
Integration into a network system can be made at any time
without losing initial hardware investment
One simple wall-mounted device to install, wire and
commission
Lower overall installation costs and quicker return on
investment
Factory-installed PIR sensor or PIR-ready controller
Provides additional automatic energy savings
Application-specific controllers
Can be configured to meet most applications
028-6035 R0_CS-VT76X6E-PIR-E00.doc
www.viconics.com / [email protected]
SPECIFICATIONS
Controller power requirements:
Operating conditions:
Storage conditions:
Sensor:
Resolution:
Control accuracy:
Occupied and unoccupied setpoint range cooling:
Occupied and unoccupied setpoint range heating:
Room and outdoor air temperature range:
Proportional band for room temperature control:
Digital inputs:
Contact output rating:
Analog output rating:
Analog output accuracy:
Wire gauge:
Dimensions:
Approximate shipping weight:
Agency Approvals all models:
Agency Approvals all models:
Agency Approvals Wireless models:
19-30 VAC 50 or 60 Hz; 2 VA ( RC & C ) Class 2
RC to RH jumper 2.0 Amps 48 VA maximum
0 °C to 50 °C ( 32 °F to 122 °F )
0% to 95% R.H. non-condensing
-30 °C to 50 °C ( -22 °F to 122 °F )
0% to 95% R.H. non-condensing
Local 10 K NTC thermistor
± 0.1 °C ( ± 0.2 °F )
± 0.5 ° C ( ± 0.9 °F ) @ 21 °C ( 70 °F ) typical calibrated
12.0 to 37.5 °C ( 54 to 100 °F )
4.5 °C to 32 °C ( 40 °F to 90 °F )
-40 °C to 50 °C ( -40 °F to 122 °F )
Factory set, heating and cooling at: 1.1°C ( 2.0°F )
Relay dry contact only across C terminal to DI1 or DI2
Each relay output: ( Y1, Y2, G, W1, W2 & AU )
30 VAC, 1 Amp. maximum
30 VAC, 3 Amp. in-rush
0 to 10 VDC into 2K resistance min.
± 3% typical
18 gauge maximum, 22 gauge recommended
4.94” x 3.38” x 1.13”
0.75 lb ( 0.34 kg )
UL: UL 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN
XAPX (US) and XAPX7 (Canada)
Industry Canada: ICES-003 (Canada)
FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US)
CE: EMC Directive 89/336/EEC (Europe Union)
C-Tick: AS/NZS CISPR 22 Compliant (Australia / New Zealand)
Supplier Code Number N10696
FCC: Compliant to: Part 15, Subpart C
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT
CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
DIMENSIONS




When replacing an existing Terminal Equipment Controller, label
the wires before removal of the Terminal Equipment Controller.
Electronic controls are static sensitive devices. Discharge
yourself properly before manipulating and installing the Terminal
Equipment Controller.
A short circuit or improper wiring may permanently damage the
Terminal Equipment Controller or the equipment.
All VT7000 series Terminal Equipment Controllers are designed
for use as operating controls only and are not safety devices.
These instruments have undergone rigorous tests and verification
prior to shipping to ensure proper and reliable operation in the
field. Whenever a control failure could lead to personal injury and
or loss of property, it becomes the responsibility of the user or
installer or electrical system designer to incorporate safety
devices (such as relays, flow switch, thermal protections, etc…)
and or an alarm system to protect the entire system against such
catastrophic failures. Tampering with the devices or unintended
application of the devices will result in a void of warranty.
VICONICS TECHNOLOGIES INC.
9245 LANGELIER BLVD. I ST-LEONARD I QUEBEC I CANADA I H1P 3K9
TEL.: (514) 321.5660 I FAX: (514) 321.4150 TOLL FREE: 1 800.563.5660
[email protected] I WWW .VICONICS.COM
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement