EDS-G512E-8PoE
Industrial Ethernet Solutions
EDS-G512E-8PoE Series
12G-port full gigabit PoE+ managed Ethernet switches
››Up to 12 10/100/1000BaseT(X) ports and 4 100/1000BaseSFP ports
››Up to 8 IEEE 802.3af and IEEE 802.3at PoE+ standard ports
• 36-watt output per PoE+ port in high-power mode
• Intelligent PoE power management functions
Operate with 240 watts full PoE+ loading at -40 to 75°C
Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250
switches), RSTP/STP, and MSTP for network redundancy
TACACS+, SNMPv3, IEEE 802.1X, HTTPS, and SSH to enhance
network security
Easy network management by web browser, CLI, USB serial
console, ABC-02-USB, MXview, MXconfig, and Windows utility
››
››
››
››
Introduction
The EDS-G512E-8PoE Series are full gigabit managed PoE+ Ethernet
switches that come standard with 8 10/100/1000BaseT(X), 802.3af
(PoE), and 802.3at (PoE+)-compliant Ethernet ports, and up to 4 fiber
optic ports.
With the gigabit Ethernet PoE+ ports, it is perfect for high bandwidth
PD device communications, such as IEEE 802.11n and IEEE 802.1ac
wireless access points and high resolution GigE machine vision
cameras for tolling systems. It can provide up to 30 watts of power per
PoE+ port in standard mode and allow high power output of up to 36
watts for industrial heavy-duty PoE devices, such as weather-proof IP
surveillance cameras with wipers/heaters, and rugged IP phones.
The EDS-G512E-8PoE Ethernet switches are highly versatile, and
the SFP fiber ports can transmit data up to 120 km from the device
to the control center with high EMI immunity. The Ethernet switches
support a variety of management functions, including STP/RSTP,
Turbo Ring, Turbo Chain, PoE power management, PoE device autochecking, PoE power scheduling, IGMP, VLAN, QoS, RMON, bandwidth
management, and port mirroring. The EDS-G512E-8PoE series are
designed especially for high bandwidth PD communications, such as
ITS and outdoor wireless access points. EMS Level 4 protection is also
available to ensure uninterrupted reliability of PoE systems.
Features and Benefits
• Advanced PoE management function (PoE port setting, PD failure
check, and PoE scheduling)
• IGMP snooping and GMRP for filtering multicast traffic
• Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network
planning
• QoS (IEEE 802.1p/1Q) and TOS/DiffServ to increase determinism
• Port Trunking for optimum bandwidth utilization
• Command Line Interface (CLI) for quickly configuring major
managed functions
• IPv6 Ready logo awarded (IPv6 Logo Committee certified)
• IEEE 1588 PTP V2 (Precision Time Protocol) for precise time
synchronization of networks
• DHCP Option 82 for IP address assignment with different policies
• Support EtherNet/IP, PROFINET, and Modbus/TCP protocols for
device management and monitoring
• Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250
switches), RSTP/STP, and MSTP for network redundancy
• TACACS+, IEEE 802.1X, SNMPv3, HTTPS, and SSH to enhance
network security
• Lock port function for blocking unauthorized access based on MAC
address
• SNMPv1/v2c/v3 for different levels of network management
• RMON for efficient network monitoring and proactive capability
• Bandwidth management to prevent unpredictable network status
• Port mirroring for online debugging
• Lock port function for blocking unauthorized access based on MAC
address
• Automatic warning by exception through e-mail, relay output
Features and Benefits
• ABC-02-USB (Automatic Backup Configurator) for system
Specifications
Technology
Standards:
IEEE 802.3af/at for Power-over-Ethernet
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
1
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
w w w. m o x a . c o m
[email protected]
Industrial Ethernet Solutions
Protocols: IGMPv1/v2/v3, GMRP, GVRP, SNMPv1/v2c/v3, DHCP
Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP,
RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, EtherNet/IP,
PROFINET, Modbus/TCP, SNMP Inform, LLDP, IEEE 1588 PTP V2,
IPv6, NTP Server/Client
MIB: MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB,
Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control: IEEE 802.3x flow control, back pressure flow control
Switch Properties
Priority Queues: 4
Max. Number of Available VLANs: 256
VLAN ID Range: VID 1 to 4094
IGMP Groups: 256
MAC Table Size: 8 K
Packet Buffer Size: 1 Mbit
Physical Characteristics
Housing: Metal, IP30 protection
Dimensions: 79.2 x 135 x 137 mm (3.1 x 5.3 x 5.4 in)
Weight: TBD
Installation: DIN rail mounting, wall mounting (with optional kit)
Environmental Limits
Operating Temperature:
Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
Interface
Fiber Ports: 100/1000BaseSFP slot
RJ45 Ports: 10/100/1000BaseT(X) auto negotiation speed
PoE Pinout: V+, V+, V-, V-, for pin 1, 2, 3, 6 (Endspan, MDI, Mode A)
USB Ports: USB console port (Type B connector)
USB storage port (Type A connector)
DIP Switches: Turbo Ring, Master, Coupler, Reserve
LED Indicators: PWR1, PWR2, FAULT, STATE, 10/100/1000M, MSTR/
HEAD, CPLR/TAIL
Alarm Contact: 1 relay output with current carrying capacity of 1 A @
24 VDC
Digital Inputs: 1 input with the same ground, but electrically isolated
from the electronics.
• +13 to +30 V for state “1”
• -30 to +3 V for state “0”
• Max. input current: 8 mA
Button: Reset button
Safety: UL 508
EMI: FCC Part 15 Subpart B Class A, EN 61000-6-4 (Industrial)
EMS:
EN 61000-6-2 (Industrial), EN 61000-4-2 (ESD) Level 4, EN 61000-4-3
(RS) Level 3,
EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 4, EN
61000-4-6 (CS) Level 3, EN 61000-4-8, IEEE 1613
Traffic Control: NEMA TS2
Rail Traffic: EN 50121-4
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Note: Please check Moxa’s website for the most up-to-date certification status.
MTBF (mean time between failures)
Time: EDS-G512E-8PoE Series: TBD
Database: Telcordia (Bellcore), GB
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Power Requirements
Input Voltage: 48 (46 to 57 V) VDC redundant dual inputs
(> 50 VDC for PoE+ output recommended)
Input Current: EDS-G512E-8PoE: TBD
Overload Current Protection: Present
Connection: 2 removable 2-contact terminal blocks
Reverse Polarity Protection: Present
Note: When selecting power supply, check the PD power consumption.
Dimensions
Unit: mm (inch)
3.5 [
0.14
]
.28]
7[ 0
M3
68.1 [2.68]
33 [1.30]
20 [0.79]
102 [4.02]
144.8 [5.70]
18 [0.71]
51.6 [2.03]
42.8 [1.69]
34 [1.34]
18 [0.71]
20 [0.79]
135 [5.31]
15.25 [0.60]
67 [2.64]
30.5 [1.20]
137 [5.39]
Front View
2
143 [5.63]
Side View
28.5 [1.12]
79.8 [3.14]
Top / Bottom Views
30.5 [1.20]
Rear View
DIN-Rail/Panel Mount Kit
w w w. m o x a . c o m
[email protected]
Industrial Ethernet Solutions
Ordering Information
Available Models
Standard Temperature
Wide Temperature
(-40 to 75˚C)
(-10 to 60˚C)
EDS-G512E-8PoE-4GSFP
Port Interface
PoE+, 10/100/1000BaseT(X)
100/1000BaseSFP*
8
4
EDS-G512E-8PoE-4GSFP-T
*Note: The EDS-G512E-8PoE series supports up to 4 100/1000BaseSFP slots. See page 3 and 4 for SFP-1G/1G
copper/1FE series Gigabit/Fast Ethernet SFP module product information.
Optional Accessories (can be purchased separately)
MXview: Moxa industrial network management software with 50, 100, 250, 500, 1000, or 2000 nodes
EDS-SNMP OPC Server Pro: OPC server software that works with all SNMP devices
ABC-02-USB: Configuration backup and restoration tool for managed Ethernet switches, 0 to 60°C
operating temperature
DR-4524/75-24/120-24: 45/75/120 W DIN-rail 24 VDC power supplies
MDR-40-24/60-24: 40/60 W DIN-rail 24 VDC power supplies, -20 to 70°C operating temperature
WK-51-01: Wall mounting kit
RK-4U: 4U-high 19” rack mounting kit
3
Package Checklist
•
•
•
•
•
•
EDS-G512E-8PoE switch
USB-IF certified cable
Protective caps for unused ports
Documentation and software CD
Warranty card
Hardware installation guide (printed)
© Moxa Inc. All Rights Reserved. Updated Feb. 24, 2014. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF